SLAB TYPE STEEL ALONG SHORT SP AN FOR TWO W AY SLAB STEEL ALONG LONG SPAN FOR TWO W A Y SLAB

STEEL ALONG LONG SPAN FOR TWO W A Y SLAB SLAB


MAIN STEEL FOR ONE W A Y SLAB DISTRIBUTION STEEL FOR ONE W AY SLAB THICKNESS
S1(ONE W AY) 8MM@ 175MM C/C 8MM @ 175MM C/C 125 MM
S2 (TWO W AY) 8MM@ 175MM C/C 8MM @175MM C/C 125 MM
S.C (STAIR CASE) 12MM@ 125MM C/C 8MM @ 175MM C/C 150 MM
SIGNA TURE OF STRUCTURAL ENGINEER:
Note: PROJECT: PLACE: STRUCTURAL CONSULTANTS:
1.Grade of concrete mix shall be M20 conforming to IS:456-2000. ARCHITECT:
GUNTUR.
2.Reinforcement shall be high strength deformed bars of grade Fe500 SCALE: NOT TO SCALE
VAP ENGINEERS (I) PVT LTD.
conforming to IS 1786-1985. TITLE:
DRAWN BY: V ASANTHA EMERALD GARDENS,
TYPICAL FLOOR ROOF SLAB DETAILS. MADHURI vapengineers08@gmail.com
3.Clear cover to reinforcement shall be 20mm. CHECKED BY: G1 CLASSIC APARTMENTS.
4.Alternate bars to be cranked at L/5 from support. DWG.NO: GSQ/GNT/805-TFRSBD.
SRIMANNARAYANA.CH
MADHAPUR,HYDERABAD
5.Extra bars to be provided for a length 0.3L on either side of supports on top face REV . NO: DESCRIPTION: REV . BY DA TE E mail:
in between crank bars. SHEET.NO:1 17-12-14 Mobile No : +91-98481-97807