Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Cooling & Heating

REVOMAX SERIES
Non-IBR Boilers instant steam generator
Engineered for consistent performance
Improving your business
is our business
Revomax Series - for
consistent performance
Thermax offers products, Against the scenario of constantly rising oil prices, more and more
systems and solutions in energy industries are shifting from light oil to heavy oil. Combustion of furnace
and environment engineering to oil in a non-IBR / instant steam generator boiler is always a challenge.
industrial and commercial And Revomax Plus is the only boiler that can provide efficient and
establishments around the world. smooth operations.
Its business expertise covers
heating, cooling, waste heat Revomax Plus -
recovery, captive power, water for heavy oils
treatment & recycling, air pollution
control & waste management and l Furnace and combustion system
performance chemicals. Thermax specially designed to burn Furnace
brings to customers extensive Oil.
experience in industrial l With small modifications fuel
applications, and expertise through flexibility is possible between light
technology partnerships and and heavy oils.
strategic alliances.
Operating from its headquarters in
Pune (Western India), Thermax Revomax Plus
has built an international sales &
service network spread over South Revomax - for light oils & gas
East Asia, Middle East, Africa,
Russia, UK and the US. It has a full Consistently high thermal efficiency
fledged manufacturing set up that Efficiency of 88% (on NCV) is derived from:
is certified for ISO 9001:2000, ISO l Reverse Flame technology
14001 and safety management l Unique patented membrane design
according to OSHAS (ISO 18000). l Built-in heat recovery device

In process heat, Thermax offers a Superior design


wide range of steam boilers, l Membrane wall design with large tube
thermal oil heaters and hot water diameter of coil ensures better steam
generators. It has expertise in a dryness, less frequent de-scaling, longer
wide range of fuels - oil, gas, solid coil life and minimum downtime
and agro-waste/ biomass. l Unique economiser-optimiser design
Supporting a broad array of ensures maximum heat recovery, protects
industries in generating, from feed water pump failure
transferring and conserving heat l Special circulation type burner design
Revomax
across a host of applications, prevents leakage and eliminates fire hazard
Thermax process heat products l Ceramic wool refractory keeps top plate
and systems are exported to North cool and makes it easy to maintain
and South America, South East
Asia, Middle East, Africa, Europe, Ease of operations & maintenance
CIS, Australia, Antarctica and l Easy access to all parts for maintenance
SAARC. l Powder-coated, well lit control panel for easy monitoring
l Built-in ladder for easy inspection and maintenance
Operating savings
Fuel consumption & operating costs for a typical 600 kgs/hr (F&A 1000C) Revomax Plus
Fuel Rate (Rs/kg)* Consumption Cost (Rs.)
FO 22.0 275 tons 60.5 Lakhs
LDO 28 260 tons 72.8 Lakhs
HSD 35 253 tons 88.6 Lakhs
*Fuel rates as landed in Pune, Maharashtra. Fuel consumption is for 7200 hrs. of operation

Savings with FO
LDO to FO HSD to FO 32%
Savings (Rs.) 12.3 lacs 28.1 lacs
Percentage 17 % 32 %

Engineered for reliable performance

Ceramic Wool
Burner
Preheated Air

Vent For Oil Preheater


Deaerated
Gases Outer Jacket

Economiser Furnace

Optimiser Pressure Part

Transparent
Filter

88%
88%
EFFICIENCY
EFFICIENCY
Cross section of Revomax Plus

Reverse Flame Technology


l With this technology the Revomax Series of boilers ensure complete combustion and

consistently high efficiency.


l Complete combustion is achieved as the flame reverses in an airtight membrane wall

furnace giving ample residence time. Additionally, any unburnt fuel is burnt with oxygen in
the secondary air coming from the burner, before flue gases leave the furnace.
Manufacturing excellence

Sustainable Solutions in
Energy & Environment

COOLING & HEATING DIVISION


Automatic TIG Welding Machine Automatic Membrane Wall Welding Machine
AHMEDABAD 380 006
Tel. : (079) 2657 5408 / 5341 / 7073
Fax : (079) 2657 7270
TIG WELD MANUAL WELD MACHINE MANUAL MACHINE MANUAL E-mail : aadmin@thermaxindia.com
BANGALORE 560 020
Tel. : (080) 2346 7761 - 64
Fax : (080) 2346 7760
E-mail : adminblr@thermaxindia.com
CHENNAI 600 018
SMOOTH,
UNIFORM BORE
NON UNIFORM,
ROUGH BORE
Tel. : (044) 2435 3831 - 34
Fax : (044) 2435 3841
E-mail : chennaidivsupp@thermaxindia.com
TIG Welding enables smooth SPM Winding ensures proper alignment,
uniform bore avoiding possibility of hot spots HYDERABAD 500 482
Tel. : (040) 2339 6820, 2331 0254
Fax : (040) 2331 2335
E-mail : hyd_sec@thermaxindia.com

Technical specifications KOLKATA 700 016


Tel. : (033) 2282 6711 - 13
Fax : (033) 2282 6796
E-mail : ksgroup@thermaxindia.com
Revomax Revomax Plus MUMBAI 400 016
Tel. : (022) 2204 5391, 2204 5324
PARAMETERS UNIT RXA-02 RXA-03 RXA-04 RXA-05 RXA-06 RXD-04 RXD-O6 RXD-850
Fax : (022) 2204 0859
Steam Output kg/hr 200 300 400 500 600 400 600 850 E-mail : madmin@thermaxindia.com
(F&A 1000C) NEW DELHI 110 057
2 Tel. : (011) 2614 5319, 2614 5701
Steam Pressure kg/cm g 10.54, 15.0 10.54, 15.0 Fax : (011) 2614 5311, 2614 8679
(SVLOP)+ E-mail : psupport@thermaxindia.com
Fuel Consumption** PUNE 411 019
- HSD / LDO kg/hr 12 18 24 30 36 24 36 51.1 Tel.: + 91-20-2747 5941
- FO kg/hr -- -- -- -- -- 25.4 38.1 54.0 Fax: + 91- 20-2747 2049/2747 5679
E-mail : shrirangd@thermaxindia.com
- Natural Gas Nm3/hr 14.8 22.2 29.5 37.0 44.3 29.5 44.3 62.8
- LPG Nm3/hr 5.5 8.2 10.9 13.7 16.4 10.9 16.4 23.2
Total Connected kW 1.9 2.3 3.0 3.2 3.2 5.3 6.2 7.0
Load (including
control panel)
Overall Dimensions INTERNATIONAL OFFICES
- Height m 1.7 2.0 2.0 2.2 2.2 2.2 2.5 3.0 n UK n USA n UAE n Thailand n Indonesia
n Russia n Kazakstan n Kenya n Saudi Arabia
- Length m 1.3 1.5 1.5 1.5 1.5 1.5 1.5 1.9 n Nigeria n Malaysia n Bangladesh
- Width m 1.1 1.3 1.3 1.3 1.3 1.3 1.3 1.5 n Sri Lanka n Chile

Dry Weight (approx.) kg 800 1000 1000 1100 1100 1000 1100 1200
www.thermaxindia.com
+
Note: SVLOP - Safety valve lift off pressure. *Efficiency is calculated as per BS 845 - Part I method. Also available: oil cum gas fired unit; higher
pressure units. **Fuel consumption is based on net calorific value (NCV) of HSD / LDO: 10,200 kCal/kg, FO: 9,650 kCal/kg, Natural Gas: 8,500 Thermax Business Portfolio
kCal/Nm3, LPG: 22,390 kCal/Nm3. Specifications given above are for altitudes up to 500 mts. above mean sea level. Ambient temperatures - 15 to
35 deg. C.
Water & Waste Solutions

Air Pollution Control

In view of our constant endeavour to improve the quality of our products,


Chemicals
we reserve the right to alter or change specifications without prior notice.
All photographs shown in this publication are representative in purpose,
and to be used for reference only. For actual details and specifications, Boilers & Heaters
please refer to Thermax offer document.

Absorption Cooling

Captive Power

You might also like