Endress Fmp51 DC

You might also like

Download as pdf
Download as pdf
You are on page 1of 1
Operating menu Levelflex FMP51, FMP52, FMPS4 HART “Level” submenu Fy Te Level submenu (> © 154) sonly visible for Operating mode (> © 138) = Level Navigation GH Setup > Advanced setup > Level ‘Medium type Navigation (Gila) Setup > Advanced setup > Level > Medium type Description Specity type of medium, User interface Factory setting Additional information # Liquid = Solid FMPSO, FMPS1, FMP52, FMP53, FMP54, FMP5S: Liquid The Solid option is only available for Operating mode (> & 138) ~ Level ‘This parameter determines the value of several other parameters and strongly influences the complete signal evaluation. Therefore, itis strongly recommended not to change the factory setting. ‘Medium property a Navigation Setup > Advanced setup > Level > Medium property Prerequsite © Operating mode (> © 138) ~ Level = EOP level evaluation * Fix DC Description Specify relative dielectric constant ¢, of the medium. Selection © Unknown, #0014. 16 #DC16..19 #DC19..2.5 C25 4 #DC4...7 © DC7...15 #pc>15 Factory setting Dependent on Medium type (> © 154) and Medium group (> © 140). Endress+Hauser