Professional Documents
Culture Documents
Symbroj Prospectus
Symbroj Prospectus
Symbroj Prospectus
90%
Save Up To
On Your Electricity Bills
Branch Office-: 1295 Bijpur Road, Waidhan, Distt-Singrauli M.P. 486886, Head Office-: 32B/14, JP Complex, Patparganj
Mayur Vihar Phase 1, Delhi
Symbroj Solar is a Leading manufactures of an innovative photo-voltaic (PV)
module and sell the best quality solar product through e-commerce platform with
promised delivery within three days across the country and recognized startup
by Govt. of India.
On-Grid or Utility
Interconnected
System
“If you have a stable grid, but
your electricity bills are high,
then the on-grid solar power
plant is recommended for
you.”
Off-Grid
System
“If you don’t have an
electricity connection or a
reliable grid and you want to
store electricity, then the off-
grid solar power plant is a
system recommend for you.”
Hybrid
System
“Hybrid solar system provides
you with the feature of both on-
grid solar system as well as
the off-grid solar system. If you
want to store power alongwith
an export facility, the hybrid
system is best for you.”
SAVIOUR SERIES
72 POLYCRYSTALLINE
SOLAR CELLS
Peak Power Pmax (Wp) 315 320 325 330 335 340 992
956
Maximum Voltage Vmpp (V) 37.5 37.7 37.8 38.0 38.1 38.2
Maximum Current Impp (A) 8.40 8.50 8.60 8.70 8.80 8.91
Open Circuit Voltage Voc (V) 45.8 46.0 46.2 46.3 46.5 45.7
Short Circuit Current Isc (A) 8.92 9.03 9.13 9.24 9.35 9.46
Module Efficiency η(%) 16.23 16.49 16.75 17.01 17.26 17.52
1) STC:1000 W/m2 irradiance, 25°C cell temperature, AM1.5g spectrum according to EN 60904-3. | 2) Power measurement uncertainty is within +/- 3%.
1956
Power (W) 233.2 237.2 240.6 244.7 248.2 251.6
V@Pmax (V) 34.6 34.8 34.9 35.0 35.1 35.2
I@Pmax (A) 6.74 6.82 6.90 6.99 7.06 7.13
Voc (V) 42.4 42.6 42.8 42.9 43.1 42.3
Isc (A) 7.22 7.31 7.39 7.47 7.56 7.64
3) NOCT irradiance 800 W/m2, ambient temperature 20°C, wind speed 1 m/sec.
Mechanical Data
Current (A)
Superstrate# 3.2 mm (0.13 inches) high transmission low iron tempered glass, AR coated 4) Average relative efficiency reduction of 5% at 200 W/m2 according to EN 60904-1.
Mechanical Load Test 5400 Pa (Snow load), 2400 Pa (Wind load) 70%
#
Also available in anti-soil and anti-glare. 1 YEAR 27
YEARS
CAUTION: READ SAFET Y AND INSTALLATION MANUAL BEFORE USING THE PRODUCT.
VIABLE SERIES
Peak Power Pmax (Wp) 365 370 375 380 385 992
956
Maximum Voltage Vmpp (V) 39.8 40.0 40.1 40.2 40.3
Maximum Current Impp (A) 9.17 9.26 9.36 9.46 9.56
Open Circuit Voltage Voc (V) 48.3 48.5 48.7 48.8 48.9
Short Circuit Current Isc (A) 9.73 9.84 9.94 10.04 10.14
Module Efficiency η(%) 18.81 19.07 19.33 19.58 19.84
1) STC:1000 W/m2 irradiance, 25°C cell temperature, AM1.5g spectrum according to EN 60904-3. | 2) Power measurement uncertainty is within +/- 3%.
1956
Power (W) 270.2 273.9 277.6 281.2 284.9
V@Pmax (V) 36.8 36.9 37.1 37.0 37.1
I@Pmax (A) 7.34 7.41 7.49 7.57 7.65
Voc (V) 44.7 44.9 45.0 44.9 45.0
Isc (A) 7.87 7.96 8.04 8.03 8.11
3) NOCT irradiance 800 W/m2, ambient temperature 20°C, wind speed 1 m/sec.
8
Mechanical Data
Current (A)
6
Length × Width × Height 1956 × 992 × 36 mm (77.01 × 39.06 × 1.42 inches)
4
Weight 20.7 kg (45.63 lbs)
Junction Box IP68/IP67, 3 Bypass diodes 2
Application Class Class A (Safety class II) 1000 W/m² 800 W/m² 600 W/m² 400 W/m² 200 W/m²
Mechanical Load Test 5400 Pa (Snow load), 2400 Pa (Wind load) 70%
1 YEAR 27
YEARS
#
Also available in anti-soil and anti-glare
CAUTION: READ SAFETY AND INSTALLATION MANUAL BEFORE USING THE PRODUCT.
The electricity that is not used in your home is then either fed into the grid (electrical
power lines) or into home battery storage. New hybrid inverters include an
integrated battery management system.
Long lasting solar power systems require a high quality inverter with a robust
convection cooling system. Low quality inverters have unfortunately failed in the
Indian climate.
Mounting structures are the backbone of a solar power plant as they provide support to
modules. These support structures raise solar panels at appropriate angles to ensure
that they receive maximum solar irradiation. Without these, solar panels are not able to
capture the required quantum of solar radiation for optimum solar generation. Proper
alignment and arrangement of mounting structures are one of the key indicators of
engineering,
Product Details:
Thickness 1.6 - 5 mm
Material Hot Dip Galvanized Iron
Brand Symbroj Solar
Structure Type Ground mounted & Rooftop
Loading Capacity 800 Kg
Module Angle 10 to 60 Degree
Features :
Well designed and experienced
Stable and high durability
Noncorrosive
Ground Mounted and Roof Top Mounted
Hot Dip Galvanized
Excellent Encapsulation
1 Phase 3 Phase
Solar DCDB
DCDB is used to protect the system if there is any fault during failure on DC side. A very
crucial part of SPV system as there should be adequate protection on DC side. The
DCDB incorporates isolator/Breaker to switch off the system during fault, there is a
meter which tells you exact PV array voltage and current you are getting. It also have
surge protection to save your system from any surges occurred due to fault or other
phenomenon.
Silent Features
Nat positive plates designed for longer life.
Quick recovery from deep discharges.
Well performed C10 rated solar battery.
2mV/per day ultra minimum self-discharge rate.
Float vent plug for electrolyte level indicator.
Extremely high life cycle 1500 @ 80% DOD.
Engineered with high-pressure die casting.
PE separators instead of PVC separators.
Special grid alloy & superior active material.
HDPE material plastic caps for enhancing lifespan.
Superior battery with leak proof vent plugs.
Easy to transport, carry and install.
Smart Lightning Arrester (SLA) is composed of one main striking point, emission
device, fixing element, and a connection to the down conductor.
The area protected by SLA is determined using the early streamer emission test
method as per NFC 17 102 Standard and it is preferred to have ASLA installed on the
highest part of the structure.
Earth Rods
Earth Rods provide low electrical resistance with the earth to allow for the dissipation
of currents. The Earth Rod is also resistant to corrosion because it will be buried
underground for a long period of time.
Worldwide, Copper Bonded Earth Rods which comply with IEC 62561 Part 2 are
some of the most popular Earth Electrodes.
Axis Copper Bonded Earth Rods are tested rigorously to meet the highest quality
standards, are approved by Utilities across the world and continue to be popular due
to their consistently high quality.