Vega T: Electronic Counter For Terminal
Vega T: Electronic Counter For Terminal
Vega T: Electronic Counter For Terminal
Metrological characteristics
• Management of one meter
• Management of 3 products
• Approved for interruptible and non-interruptible measuring
systems according to MID European Directive
• Software certification with the following extensions (Welmec
Guide 7.2):
- Extension S (Software separation):
the metrological part of the software is separated from the automation one;
- Extension L (Long term data storage):
delivery data (250 deliveries) are saved and stored in a structure with MID criteria. Data can also be downloaded
via serial line or directly consulted on the display thanks to a specific tool.
- Extension T (Legally relevant data transmission): delivery data can be sent to a PC, to a printing system or to a
printer via serial line with legally relevant protocol.
• Management of ISOIL printer ST500-M
• Access to all the parameters by password (3 levels) and Weight & Measure Switch
• Log parameters modification function
• Continuous self-diagnosis
Hardware characteristics
• Ex-d explosion proof ATEX approved • n°4 Ex-d digital inputs, fully programmable
• Serial communication ports: n° 2 EIA-RS232, • n°7 power outputs, fully programmable
n°2 EIA-RS485, n° 1 EIA-RS422/RS485, • n°4 digital outputs or programmable pulses
• Backlighted LED graphic display outputs
• Numeric and multi-function membrane keyboard • n° 2 analog inputs 4÷20 mA (optional) for density
• Configurable counting inputs push-pull, open- acquisition
collector • n° 2 analog outputs 4÷20 mA (optional) for remote
flow rate and temperature indication or analog
• n°6 Ex-ia digital inputs, fully programmable
value control.
DS/VE/0015/EN
Functional characteristics
• Drop-down menu with detailed descriptions • Setting of measurement unit (one customized
• User interface with clear messages measurement unit can be set)
• Clear messages for alarms and incorrect operations • Temperature compensation with API/ASTM tables
• Adaptability to many different automation and for compensated volume and mass
configuration modes • Product temperature reading via 3/4 wires PT100
• Management of up to 3 products with the same thermoresistance
meter thanks to independent identification labels, • Stand-alone or remote mode (host controlled) via
meter factor, density, etc. ASCII proprietary or ModBus (RTU) protocol
• Management of top and bottom loading • Direct management of printing with configurable
• Management of FlexiMix additive injection system reports
via RS485 serial communication line • Diagnostic applications
• Management of preset valves (2 stages, multistep • 6 emergency functions 3 of which can be
and analog valves) configured
• Management of preset multiple of 1000 or free • Terminal display management: the TAS can show
and automatic management of final adjustment messages and data entry fields on the display of
VEGA T
• Management of identification via pincode and
• Remote output management: the TAS can manage
configuration of interlocks
free relays or digital outputs via serial message.
Functions
Density acquisition Base density (standard conditions) or observed density (ambient temperature) can be
acquired via 4÷20 mA input.
VEGA T calculates the density average value during product delivery.
Temperature VEGA T (with compensating function) enables calculation of product volume with reference to
compensation base temperature (Tb), usually 15°C or 20°C, for the following products:
(optional) • petrochemical products with configurable API compensation tables (6A, 6B, 6C, 24A, 24B,
53A, 53B, 53D ,54, 54A, 54B, 54D, 60A, 60B, 60D) and BRASIL table.
• ethanol products according to OIML R22 and NBR5992 tables.
• biofuels with PTB table for temperature compensation of minerals and biofuel mixtures.
Alternatively compensation with the ALFA cubic expansion coefficient can be used.
Operations
When in local mode VEGA T can manage product delivery according to the enabled functions and perform the following
operations:
• select product via keyboard or external selector
• select type of loading (top/bottom) via external selector
• check interlocks and signals
• set the preset
• start product delivery from keyboard or external button
• open selector/shut-off/ vapour recovery valves, and start pump according to the timing set in the pertaining
parameters
• management of the loading process via preset valves. In this stage, besides product measurement, VEGA T
performs flow rate, temperature and automation control
• close the preset when the preset product quantity has been delivered
• close selector/shut-off/ vapour recovery valves, and stop pump according to the timing set in the pertaining
parameters
• summarize data and print loading reports.
Delivery management
When in remote mode VEGA T is controlled by a TAS (Terminal Automation System) and once initialized it works
independently controlling product delivery by means of the devices it is connected to. The system can control the
following functions:
• identification of operator via pin code or badge and loading permission management
• delivery start and stop, method selection (top/bottom loading, automatic/semiautomatic), reset of quantity, density
update
• enabling/disenabling meter
• alarm reset
• data acquisition (status)
• preliminary and final data summary
• download of product delivery data.
Remote control is achieved though serial communication with proprietary or ModBus RTU protocol.
Valves
VEGA T can manage different valve types:
• Two stages: two stages valve allows supply of the preset quantity by controlling the two solenoid valves (one for
Low flow and one for High flow). Flow rate values can be pre-set by acting mechanically on the valve while the VEGA
T manages low flow stage at the beginning of product delivery, high flow stage and low flow at the end of flow rate
in order to avoid splash phenomena and the formation of foam. The duration of the different phases can be set in
the specific parameters. Moreover the automatic final adjustment function can be used: if required, the preset ends
with a series of short valve openings until the exact preset value is reached.
• Multistep (digital valve): this valve not only allows managing of the initial and final low flow stage, but it also allows
for dynamic regulation of flow rate at pre-set value by acting on the solenoid valves (one NO and one NC). This
regulates the position of the valve diaphragm.
This valve has a default high flow rate value and two lower high flow rate values that can be controlled by two
digital inputs. Flow rate can alternatively be set via serial line message.
• Analog (4÷20 mA): VEGA T can drive any valve with suitable hydraulic characteristics thanks to the 4÷20 mA signal.
Product delivery and flow rate values are managed in the same way as for digital valves.
Ticket printing
VEGA T can print two configurable tickets with a set of specific parameters via serial line protocols. Tickets can be
printed with the following ISOIL printers:
• ST100 - impact dot matrix printer (blank or pre-printed ticket)
• ST500-M
The system allows connection of up to 16 electronic counters in multi-point via RS422 or RS485 serial line. The
ST500-M collects data from each VEGA T and sends them to a 80 columns printer. Data can be checked and
managed thanks to CRC16.
Each digital input can be programmed as “consent” for loading (interlock) or as signal linked to a specific function.
If the configuration is made as interlock, you can select:
• input logic (OK if closed, OK if open)
• type of loading (top, bottom, top and bottom)
• action (functions with optional command to configurable D/O)
• label (signal meaning is shown in full on the display) among the following:
Interlock number, Interlock from Badge Reader, Grounding, Top/bottom Loading Arm, Tank Truck Presence, Manual
valve, Top/Bottom Loading Arm Manual valve, Vapour Recovery Valve, Top/Bottom Loading Vapour Recovery Valve,
Overfilling, Overfilling of Top/bottom Loading, Dead man, Dirty strainer, Emergency, Bay Emergency Stop, Vapour
Recovery, Tank level, Right/Left Loading Arm, Right/Left Grounding System.
• Three more labels can be configured as needed: for each customized consent the operator has 4 lines of 15 digits
each.
Each input configured as signal can be associated to a specific function. It is therefore possible to select loading type
(top/bottom) and one of the following signal types:
General Signal, Remote Start, ATB/ATK Preset Remote Start, Remote Stop, ATB/ATK Preset Remote Stop, Local/Remote
Selector, Top/Bottom Loading Selector, ATB/ ATK Selector, ATK Preset Selector, Anti-overfilling Bypass, Open/Closed
Vapour Recovery Micro Valve, Open/Closed Block Micro Valve, Product Selection, Start/Stop ON/OFF, Additive injection
not ready, Additive pump, Flow Reduction, Injection Piston Feed-back, Gas Extractor Level (STOP/LF).
Outputs
VEGA T has several outputs (see Technical Data table), each one can be associated to a specific function (see
Parameters Manual).
Data type of pulses (volume, compensated volume and weight) and k factor (multiplication factor) can be defined for
each output.
Additive injection
VEGA T manages product additive injection :
• by connecting to smart additive injection devices, receiving pulses according to the quantity and control the
hydraulic circuit with a dosing valve, piston or pump for product delivery according to the required percentage.
VEGA T allows you to control two separate devices with a maximum of four additives, each using the following
digital signals:
- n° 2 D/O (digital output) to select device
- n° 4 D/O (digital output) to select additive
- n° 2 D/I (digital input) to acquire alarms.
By combination of different function modes up to 6 additives can be injected at the same time.
Dimensions Accessories
Dimensions in mm • EM6422 pulse emitter
• ST101, ST500-M printers
• A class PT100 thermoresistance
• LFD-6 display
• SBR Serial Badge Reader
Code example: X 2 9 5 - 1 N X 3
Fixed value 2
Single meter 9
Fixed value 1
Fixed value N
Fixed value 3
Technical data
Environmental features
Working temperature: -25 ÷ +55°C (-13÷131°F)
Storage temperature: -25 ÷ +65°C (-13÷149°F)
temperature probe:
4÷20 mA Inputs: n°2 4÷20 mA two wires, input resolution: 16 bits (65 536 points)
4÷20 mA Outputs: n°2 4÷20 mA two wires, output resolution: 16 bits (65 536 points)
n°4 current source externally powered outputs (5 ÷ 30 Vdc)
Digital outputs:
Imax=1 A each
Digital power outputs: n°7 of which:
• 3 mechanical relays (all versions)
• 4 Vac/Vdc solid state relays (according to VEGA T power supply)
Serial communication: 2 lines RS485 two wires
2 lines RS232 (RX, TX, COM)
1 line RS422/485 four wires
ATEX: II 2(1) G Ex d [ia Ga] ib IIB T6 Gb - INERIS 05ATEX0034X approval
Mechanical protection: IP66