Spectrus DT1400: Inactivating Agent For Spectrus CT1300

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Fact Sheet

Spectrus* DT1400
Inactivating Agent for Spectrus CT1300
• Eliminates the active ingredient (ADBAC Quat) in Spectrus NX1104 (DGH/Quat combination) com-
Spectrus CT1300 monly used to control microbiological fouling
• Neutralizes other cationic biocide actives bio- caused by algae, bacteria and/or fungi in commer-
cides, as well cial and industrial water systems can also be inacti-
vated by Spectrus DT1400.
• Reduces effluent toxicity
• Assists compliance with NPDES permits Treatment and Feeding Requirements
• Highly concentrated aqueous suspension Typical Dosage – To protect all aquatic life-forms,
• Ready for use, no make-down required feed a maximum of 32.6 mg/L of Spectrus DT1400
• Cost effective for every 1 mg/L of Spectrus CT1300 fed.
For inactivation of Spectrus NX1104, feed a maxi-
Description and Use mum of 8.5 mg/L of Spectrus DT1400 for every 1
Spectrus DT1400 is a specially formulated aqueous mg/L of Spectrus NX1104 fed.
suspension designed to remove cationic materials To calculate the Spectrus DT1400 feedrate for de-
from bulk water. Spectrus DT1400 can reduce the toxification of Spectrus CT1300: [Spectrus CT1300
toxicity of cooling tower blowdown and plant efflu- dosage (mg/L) x flow rate (gpm) x 8.34 x 32.6]/106 =
ent associated with cationic biocides such as qua- lb/min DT1400
ternary amines (e.g. ADBAC and DMAC types) or
guanidines (e.g. DGH). Toxicity reduction is accom- To calculate the Spectrus DT1400 feedrate for de-
plished by adsorption of these actives to the ingre- toxification of Spectrus NX1104: [Spectrus NX1104
dients in DT1400. Adsorbed cationic biocides can dosage (mg/L) x flow rate (gpm) x 8.34 x 8.5]/106 =
then be degraded by natural microbial populations. lb/min DT1400
When used following application of cationic bio- These feed rates are constant over a pH range of
cides, Spectrus DT1400 can assist in complying with 6.0 to 9.0.
NPDES discharge regulations.
Test Method – Use field test methods (e.g., AP412 or
AP413) to confirm removal of CT1300 from freshwa-
Typical Applications ter or seawater, respectively.
As a result of increasing environmental concern and Feed Equipment – Spectrus DT1400 is easily fed
regulations regarding residual biocides in effluent with an air driven double diaphragm pump such as
water, Spectrus DT1400 was developed to provide a Wilden Model M-1.
simple way to inactivate cationic biocides prior to
discharge. Note: Spectrus DT1400 can separate on standing.
The product must be thoroughly mixed prior to use
Spectrus DT1400 can be used to inactivate a num- to ensure ingredients are fed at a uniform rate.
ber of nonoxidizing biocides. These include ’s Spec-
trus CT1300 (50% quaternary amine) often used to Dilution – This material is best fed neat, however, if
control macrofouling caused by mollusks in a vari- necessary, Spectrus DT1400 can be diluted to assist
ety of industrial and influent water systems. product feed. If diluted, the dilution factor must be

Find a contact near you by visiting www.ge.com/water and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2009, General Electric Company. All rights reserved.

fs1235en.doc Jul-09
incorporated into the detoxification ratio and the Packaging Information
diluted slurry must be constantly mixed to prevent
separation. DT1400 is available in a wide variety of customized
containers and delivery methods. Contact your GE
Feed point – Feed Spectrus DT1400 to a point in the Water representative for details.
system where it will rapidly mix with the biocide-
treated water. The reaction with residual cationic Storage
biocide is almost instantaneous, however, for added
safety in direct discharge applications, begin feed- Store at temperatures between 40°F (4°C) and
ing Spectrus DT1400 10 minutes prior to start of 100°F (38°C). Protect from freezing. If frozen, thaw
biocide feed. Continue feeding Spectrus DT1400 and mix completely prior to use.
until all upstream waters containing biocide have
been discharged. Safety Precautions
Compatible Materials - Tanks, pumps, piping, and A Material Safety Data Sheet containing detailed
valves should be made of polyethylene, polypropyl- information about this product is available upon
ene or PVC. Mild steel is not acceptable for use with request. See Section 8 of the MSDS for recom-
this product. mended personal protective equipment.

General Properties
Physical properties of Spectrus DT1400 are shown
on the Material Safety Data Sheet, a copy of which
is available on request.

Page 2 Fact Sheet