1-01 1-02 1-03 1-04 1-05 1-06 1-07 1-08 1-09 1-10 1-11 1-12 1-13 1-14 1-15

1-06 1-07 1-08 1-09 1-10 1-11 1-12 1-13 1-14 1-15 1-16 1-17 1-18 1-19 1-20 1-21 1-22 1-23 1-24 1-25 1-26 1-27 1-28 1-29 1-30 1-31 1-32

T3
A 4-N02
From impact hammer
(option)

T4
EN857-2SC
2-L04
5/8" From feeder
B
T2
2-M24
EN857-2SC
From main conveyor

G1/2

G1/2
G3/4

G3/4
G1
G1
1"

G1
31

G1
G1

G1
lifting / lowering

X
X

X
X

X
EN857-2SC EN857-2SC
G 1½ G 1½ 1 1/2" 1 1/2"
C X
G1½

G1½
X
M10X1

G1½

G1½
G1/4
M
D

25

EN857-2SC
T

M10x1

1 1/2"
I
E 3 2B21

32 T1
2-V07
From main valve block
COOLER
F To impact hammer
Max speed (~1700 rpm) to be limited
FAN DRIFE HYDRAULIC OIL COOLER
(option)
WHEN EXTERNAL ELECTRIC using pump adjustment screw :
4-O03
P3 POWER SUPPLY IN USE Fan speed 180 bar at max. diesel engine speed
~1000±50 rpm (32-35 l/min)

G
To main conveyor 2-K06
P6 5
lifting / lowering From main valve block

M
2-O24
P2
V 25

G3/4
EN857-2SC
U
1"
32
To hydraulic box
H 2-T07
87 V
P1

EN857-2SC
3/4"
EN857-2SC
1/2"
I

EN857-2SC
7/16-20
UNF-2B
OUT

X
3/4"
J
LS1
2B41

17
2-U07
11 From main valve block
BAR

K Diesel engine:
IN 180 1500rpm (50Hz)
Y205 BAR
1800rpm (60Hz)
25

M10X1

G1/4
G1½

G1½
M
16

X
X
G

G1½
G1½
X SAE 3/4" X
L
3000 Psi

X
B
31

G1/2
X

G1/2
G1

G3/4

G1

G3/4
G1

G1

G1
G1
M
EN856-4SH i=0.877 (up)
1" Setting
21
Adj.
BAR
2-I11
M
L2
1480 rpm (50 Hz): 320
cw
M Tracks
Qmax=141 l/min BAR
2-A14
(vol. eff. 0,95) B 45 L3

1785 rpm (60 Hz): Hand Valves


N 3-R04
Qmax=170 l/min SAE 1¼"
S T5
3000 Psi

X
(vol. eff. 0,95) EN857-2SC
L L1 3/4"
EN857-2SC
1/2"
100 Feeder
2-I01

EN857-2SC
O L1
55kW

1 1/2"
1 1/4"
SPIRTEX

50 Hz, 1480rpm EN857-2SC


1" Drive speed valve
400/490 V 2-J07
60 Hz, 1785 rpm EN857-2SC L5
X

3/4"
460 V S L1 L
5/8"
P EN857-2SC

85
3" "POSIO"
SAE100R4

Inside G1½

ø38X2.5
ø 76 mm

Q
12
FLAP VALVE 2S13
SAE 1½"
DN125
3000 Psi G1½

X
G1

G1½

R 2B20
G1/8

35
tank
emptying
G3/4
PAINETOLERANSSIT / PRESSURE TOLERANCES
X < 50 bar ± 1bar
EN857-2SC
R½" 50 - 300 bar ± 3 bar
S TANK OIL OUTLET 1/2"
> 300 bar ± 5 bar
HUOM. KAIKKI KÄYTTÄMÄTTÖMÄT LISÄVARUSTELIITÄNNÄT TULPATAAN HUOM. KIERREMERKINNÄT: R-kierre (BSP) = G-kierre (ISO 228/1)
NOTE. ALL THE UNUSED OPTION CONNECTIONS TO BE PLUGGED NOTE. THREAD TYPES: R thread (BSP) = G thread (ISO228/1)
(esim. / e.g. R3/4" (3/4" BSP) = G3/4")
T
Rev. No Date Name Description Location
of
0 0
Used on Work no Project Project rev.
MM0433923 0
U Module Approved for Drawing No
Drawn 20.10.15 TREHURUIL production 27.10.2015
AKO

MM0433924
Chec- for serial
ked 20.10.15 TREHURUIL production
Mass kg for license
production
Type Title Page/Of pages
V HYDRAULIC DIAGRAM
MH LT120E 1/ 4
2-01 2-02 2-03 2-04 2-05 2-06 2-07 2-08 2-09 2-10 2-11 2-12 2-13 2-14 2-15 2-16 2-17 2-18 2-19 2-20 2-21 2-22 2-23 2-24 2-25 2-26 2-27 2-28 2-29 2-30 2-31 2-32

EN857-2SC To leak block


1/2" 1-M26
A L3

TRACK DRIVE, LEFT TRACK DRIVE, RIGHT


DRIVE SPEED

EN857-2SC

EN857-2SC
Slow drive:

1/2"
B

1/2"
JARRU i=147 i=147 JARRU ~3 track pads / 10s
BRAKE Tmax=76 kNm Tmax=76 kNm BRAKE

Gen. set 50 Hz (pump 1480 rpm) :

M18x1,5

M18x1,5
M18x1,5
Vgmax=107ccm Vgmax=107ccm
Normal drive ~0,5 km/h, motor at Vgmax (107 ccm)
C Vgmin=65 ccm Vgmin=65 ccm
T T T T
X
Fast drive ~0,85 km/h, motor at Vgmin (65 ccm)
X
M18x1,5

X X
3/8" 3/8"

M14x1,5
M14x1,5
EN857-2SC EN857-2SC
Gen. set 60 Hz (pump 1785 rpm):
Normal drive ~0,6 km/h, motor at Vgmax (107 ccm)
D

Vgmax
Fast drive ~1,0 km/h, motor at Vgmin (65 ccm)

Vgmax

Vgmin
M14x1,5
Vgmin

M14x1,5
400 400 400 400
BAR BAR MA BAR BAR MB
MB
X XM X X
EN857-2SC
1/4"

M14x1,5
A
M14x1,5

EN857-2SC
X XS
S

M22x1,5
M22x1,5

1/4"
HYDRAULIC SETTING ADJUSTMENT FOR CRUSHER

ø100/56 X 250

ø100/56 X 250
F

R¾"
MAIN CONVEYOR LIFTING / LOWERING

R¾"
Bre Bre EN857-2SC
27 EN857-2SC
27
G
M14x1,5 SAE 1" SAE 1" SAE 1" SAE 1" M14x1,5 3/8" 3/8" LEFT RIGHT
EN857-2SC

6000 Psi 6000 Psi A A 6000 Psi 6000 Psi


B
B
3/8"

4l EN857-2SC
13 13

5/8"
SAE100R2T
½"

ø80/50 x 350
17 ROCKMASTER ROCKMASTER
100 bar prefill → setting increases 17...23s
H 2PLUS 2PLUS 17 Accumulator MM0319989
29

G3/8
3/4" 3/4"

G3/8
EN857-2SC
ROCKMASTER ROCKMASTER EN857-2SC
← setting decreases 17...23s
86 2PLUS 2PLUS 5/8" EN857-2SC EN857-2SC

R 1/2"

ø60/32 x 250

ø60/32 x 250
G1/4

3/8"
VIBR. FEEDER (V175) 3/8"

3/8"
3/4" 3/4"
2
L2
Max. 34 l/min 1-M26 Time from 0 bar to
EN857-2SC Max. 1050 rpm To leak block

G3/8
Y453 ø80/50 x 350
max. pressure level: 15...25s

G3/8
I L1 1/2"
M16x1,5 3
G1/4

G1/4

1-O26 23 l/min 1
To leak block 700 ± 25 rpm

M27x2 M27x2
B450
I
23 M
25 EN857-2SC EN857-2SC
32
3/8" 3/8"
To leak block P G¼" ø12X1,5
1-P26 EN857-2SC
J ANTURIN SÄÄTÖ
L5 A1 3/8"

1 EN857-2SC
SENSOR SETTING 33 G3/8

EN857-2SC EN857-2SC
135..155 BAR

ø20X2,5

ø20X2,5
EN857-2SC 3/8" 3/8" 3/8"
1/2" EN857-2SC
5/8"
G1/4 B G1/4 A
K P6 G3/8
1-G13 A
ø20X2,5

ø20X2,5

To cooler fan motor


ø16X2
EN857-2SC
1/2" EN857-2SC EN857-2SC 250
5/8" To tank block 3/8" BAR
ROCKMASTER ROCKMASTER G3/8
L
T4
1-B31
2PLUS
3/4"
2PLUS
3/4" 3B32 23 ROCKMASTER ROCKMASTER
C1 C2
Y282

G3/8
2PLUS
M
25 To hand valves
3-O04
3/4"
2PLUS
3/4"
54 25
I

P5 25
P

25 25 ø20X2,5
25 ø20X2,5
55 V1 V2 T2 T M

M G1/4
25 ø12X1,5
1-B31

A
B
EN857-2SC G1/4
M M
25 M M
25 M To tank block
1/2"
ø 2 mm G1/4

M M G1/2 G1/2" Main conveyor lowering


G1/2 G1/2 G1/2 G1/2 G1/2 G1/2 G1/2 G1/2 G1/2 G1/2
X

X
A B A B A B B A B A B A (control with Y280)

3/8"
N
280 280 50
BAR BAR BAR

210 P2

B
A
280 280 M G1/4 P
O BAR BAR BAR 1-G07
From device pump
EN857-2SC G1/4
6
Y303A Y350 Y351 Y452B Y450 3/8"
Y260 Y303B Y452A

Y281
30 38 Main conveyor lifting
P LS from main conveyor lifting
(Without impact hammer)
LS3
2-Q24 LS G1/4
LS3 LS3
2-Q24 2-P21
2-Q21 EN857-2SC
Q LS from main conveyor lifting

1
160 310 310 250 (With impact hammer) 3/8"
BAR BAR 180 BAR

G3/4"
BAR
END PLATE

BAR
350 BAR
157B2920

2
250 310 40 250
BAR
310
77
END PLATE
BAR BAR BAR BAR

157B2920

77
3
R LS2
PAINETOLERANSSIT / PRESSURE TOLERANCES
< 50 bar ± 1bar
26 4-P02
LS from impact hammer 50 - 300 bar ± 3 bar
G1/4
> 300 bar ± 5 bar
G1/4 ø12X1,5
ø12X1,5

G3/8 LS LS
X X G3/8 ø0.6mm
S P P T6 HUOM. KAIKKI KÄYTTÄMÄTTÖMÄT LISÄVARUSTELIITÄNNÄT TULPATAAN
G1/2
3-M11
G1/2 T G¼ G¼ T NOTE. ALL THE UNUSED OPTION CONNECTIONS TO BE PLUGGED
From main conveyor folding valve
X

G¼ G1 G¼ G1 G¼
P
Max. 65 l/min Max. 100 l/min LS T Max. 40 l/min HUOM. KIERREMERKINNÄT: R-kierre (BSP) = G-kierre (ISO 228/1)
Max. 65 l/min Max. 100 l/min Max. 10 l/min
M

NOTE. THREAD TYPES: R thread (BSP) = G thread (ISO228/1)


EN856-4SH (esim. / e.g. R3/4" (3/4" BSP) = G3/4")
T 1"
P1
1-H07
From device pump 25 Rev.
0
No
of
0
Date Name Description Location

Used on Work no Project Project rev.


MM0433923 0
U LS1
1-J08 Module Approved for Drawing No
To device pump
3/8"
EN857-2SC
Drawn 20.10.15 TREHURUIL production 27.10.2015
AKO
M

MM0433924
Chec- for serial
ked 20.10.15 TREHURUIL production

EN857-2SC
25 Mass kg for license
production
T1 1 1/4" Type Title Page/Of pages
V 1-F31 HYDRAULIC DIAGRAM
To tank block
MH LT120E 2 /4
3-01 3-02 3-03 3-04 3-05 3-06 3-07 3-08 3-09 3-10 3-11 3-12 3-13 3-14 3-15 3-16 3-17 3-18 3-19 3-20 3-21 3-22 3-23 3-24 3-25 3-26 3-27 3-28 3-29 3-30 3-31 3-32

MAIN CONVEYOR FOLDING (OPTION)

48 25 FOLDING 40...60s
STRAIGHTENING 65...95s
25
48
C LEFT RIGHT

M
C P P C

G1/2
G1/2 G1/2 G1/2


BAR BAR
110 110

UP

DOWN
D

49 49


G3/8
LOCKING OF FEED HOPPER FLANKS LOCKING OF FEED HOPPER FLANKS
G3/8 EN857-2SC EN857-2SC LEFT RIGHT
E ø80/56 x 830 ø80/56 x 830 1/4" 1/4"

71 LIFTING / LOWERING OF FEED HOPPER FLANKS 71


50 50 EN857-2SC
G1/4 G1/4
EN857-2SC
1/4"
Laidat ylös / Flanks up: 10...13 s EN857-2SC
1/4" EN857-2SC
F 3/8" Laidat alas / Flanks down: 10-20 s 3/8"

ø40/20 x 230

ø40/20 x 230
LEFT RIGHT
EN857-2SC EN857-2SC
1/4" 1/4"

G3/8 G3/8

ø60/40 x 400
G

ø60/40 x 400
EN857-2SC G1/4 G1/4 EN857-2SC
3/8" 3/8"

ø12x1,5

ø12x1,5
71 71
EN857-2SC
H 1/4" G1/4 G3/8
BACK G1/4
EN857-2SC G3/8 EN857-2SC
3/8" 3/8"

ø40/20 x 230

ø40/20 x 230
A1
G3/8

G3/8

ø60/40 x 400
33 14 14
I

ø12x1,5
G3/8

A EN857-2SC G1/4 G1/4 EN857-2SC


3/8" 3/8"
EN857-2SC EN857-2SC
3/8" 3/8"
G3/8
J
EN857-2SC
1/4" EN857-2SC
EN857-2SC 3/8" EN857-2SC
3/8" 14 3/8"
G3/8 G3/8
C2 C1
K C2 C1

EN857-2SC
3/8"
V2 V1 V2 V1

L
EN857-2SC 55 55
3/8" EN857-2SC
EN857-2SC EN857-2SC EN857-2SC
3/8"
3/8" 3/8" 3/8"

EN857-2SC
1/2"
To main valve block
M 2-S25
T6

A G3/8
B G3/8

A G3/8

B G3/8

A G3/8

B G3/8

A G3/8

B G3/8

A G3/8

B G3/8
P2 B A T2 P2 T2

X
X

X
N G1/2
G3/8

G3/8

G1/2

G1/2
G1/2
25 4

20 1
20 1
2 0 1

20 1
20 1

20 1
M
O
G1/2

G1/2
P5 P1 N P1 N
2-M08 3/8" 3/8"" X
EN857-2SC G1/2 EN857-2SC G1/2

B
P

B
P

B
From main valve block Note: Use carry-over plug pos.41 here! Note: Do not use carry-over plug here!

A
A

A
A
T

T
T

T
T
P 41
84
1

1
1

1
250
T1 250

2
2

2
BAR
X
G1/2 BAR
Q T1

R
To leak block
1-N26 1/2"
EN857-2SC
T5
PAINETOLERANSSIT / PRESSURE TOLERANCES
< 50 bar ± 1bar
S 50 - 300 bar ± 3 bar
> 300 bar ± 5 bar
HUOM. KIERREMERKINNÄT: R-kierre (BSP) = G-kierre (ISO 228/1)
HUOM. KAIKKI KÄYTTÄMÄTTÖMÄT LISÄVARUSTELIITÄNNÄT TULPATAAN
NOTE. THREAD TYPES: R thread (BSP) = G thread (ISO228/1)
NOTE. ALL THE UNUSED OPTION CONNECTIONS TO BE PLUGGED
(esim. / e.g. R3/4" (3/4" BSP) = G3/4")
T
Rev. No Date Name Description Location
of
0 0
Used on Work no Project Project rev.
MM0433923 0
U Module Approved for Drawing No
Drawn 20.10.15 TREHURUIL production 27.10.2015
AKO

MM0433924
Chec- for serial
ked 20.10.15 TREHURUIL production
Mass kg for license
production
Type Title Page/Of pages
V HYDRAULIC DIAGRAM
MH LT120E 3 /4
4-01 4-02 4-03 4-04 4-05 4-06 4-07 4-08 4-09 4-10 4-11 4-12 4-13 4-14 4-15 4-16 4-17 4-18 4-19 4-20 4-21 4-22 4-23 4-24 4-25 4-26 4-27 4-28 4-29 4-30 4-31 4-32

Metso Boom 30 + Metso Hammer 400


B
(OPTION)

Required oil flow


D 50 - 90 l/min

T3 G3/4
1-A31
To tank block EN857-2SC G3/4 EN857-2SC
3/4" 3/4"
N

P3 G1/2
61
1-F07
From device pump EN856-4SP G1/2 EN856-4SP
O 5/8" 5/8"

LS2 G3/8
2-R21
P
To main valve block G3/8 EN857-2SC
EN857-2SC 3/8"
3/8"

PAINETOLERANSSIT / PRESSURE TOLERANCES


< 50 bar ± 1bar
S 50 - 300 bar ± 3 bar
> 300 bar ± 5 bar
HUOM. KAIKKI KÄYTTÄMÄTTÖMÄT LISÄVARUSTELIITÄNNÄT TULPATAAN HUOM. KIERREMERKINNÄT: R-kierre (BSP) = G-kierre (ISO 228/1)
NOTE. ALL THE UNUSED OPTION CONNECTIONS TO BE PLUGGED NOTE. THREAD TYPES: R thread (BSP) = G thread (ISO228/1)
(esim. / e.g. R3/4" (3/4" BSP) = G3/4")
T
Rev. No Date Name Description Location
of
0 0
Used on Work no Project Project rev.
MM0433923 0
U Module Approved for Drawing No
Drawn 20.10.15 TREHURUIL production 27.10.2015
AKO

MM0433924
Chec- for serial
ked 20.10.15 TREHURUIL production
Mass kg for license
production
Type Title Page/Of pages
V HYDRAULIC DIAGRAM
MH LT120E 4 /4