Project: By:
Calculation: Attenuation System Design
Your Logo /
Company Approved:
Details Here Sheet Number: Cover Sheet Date:
Although all care and attention has been taken to ensure that this
program is accurate, CivilWeb gives no guarentee that it is error free.
In no event will Civil Web accept any responsibility for any errors or
omissions from the program or from the user of the program, or for
any special, incedental or consequential damages whatsoever
arising from use of this program.
Registered User;
Free Trial Version
Revision Schedule
Registered User: Free Trial Version - Not For Commercial Use © 2017 CivilWeb
Project: By:
Calculation: Attenuation System Design
Your Logo /
Company Approved:
Details Here Sheet Number: 1 Date:
Catchment Details
Catchment Area 4,000 m²
Runoff Coefficient 0.85
Location Code C
Return Period 10 years
Climate Change Factor 5 %
UK Rainfall Map
Colebrook-White Calculation
Colebrook-White Calculation
Project: By:
Calculation: Attenuation System Design
Your Logo /
Company Approved:
Details Here Sheet Number: 2 Date:
Results Table
Storm Duration (Mins) Inflow (l) Outflow (l) Storage Required (m³)
5 26,626 3,000 24
10 39,806 6,000 34
15 48,731 9,000 40
30 65,867 18,000 48
45 77,112 27,000 50
60 85,680 36,000 50
120 108,528 72,000 37
240 135,660 144,000 0
480 171,360 288,000 0
60
50
50
Storage Required (m³)
40
30
20
10
0
0 60 120 180 240 300 360 420 480
Storm Duration (Mins)
10
0 Colebrook-White Calculation
0 60 120 180 240 300 360 420 480
Storm Duration (Mins)
Colebrook-White Calculation
0
5
10
15
30
45
60
120
240
480
Colebrook-White Calculation
Colebrook-White Calculation
Colebrook-White Calculation
Colebrook-White Calculation
Colebrook-White Calculation
Colebrook-White Calculation
Registered User: Free Trial Version - Not For Commercial Use © 2017 CivilWeb
Project: By:
Calculation: Attenuation System Design
Your Logo /
Company Approved:
Details Here Sheet Number: 1 Date:
Catchment Details
Catchment Area 9,000 m²
Runoff Coefficient 0.85
Design Storm Intensity 15 mm/hr
Design Storm Duration 60 mins
Results