Professional Documents
Culture Documents
Tegral Built Up Systems
Tegral Built Up Systems
• Architectural Profiles
• Acoustic Systems
• Sustainable Systems
Tegral have supplied Roofing, Cladding, Flat Roof Deck, ComFlor® Composite Floor Decking and
Zeta® Purlins to some of the most prestigious and innovative developments in Ireland
www.tegral.com
an GROUP company
Armacor, Celestia, Colorcoat, Colorcoat Connection, Confidex, HPS200, Prisma and Repertoire are all registered trademarks of Corus.
Care has been taken to ensure that the contents of this publication are accurate, but Tegral Metal Forming Ltd. and its related companies do not accept responsibility for
errors or for information which is found to be misleading. Suggestions for, or descriptions of the end use or application of products or methods of working are for
information only and Tegral Metal Forming Ltd. and its related companies accept no liability in respect thereof. Before using products supplied or manufactures by Tegral
Metal Forming Ltd. and its related companies, the customer should satisfy himself/herself of their suitability.
Our Company Our Partners This guide covers the key elements, issues Our guiding principles are objectivity and
Tegral Metal Forming is part of the Tegral Through a long-standing partnership with and considerations the designer faces when professionalism, our goal is to help our
Group and a subsidiary of the Etex Group, a Corus, a world-renowned manufacturer selecting roofing and cladding materials. customer find the right solution and our
world-renowned international building of steel and aluminium, Tegral customers We offer metal cladding solutions that commitment to quality and excellence in
products company. For over 25 years, and specifiers are assured of the highest include twin-skin systems, site assembled everything we do, remains constant.
Tegral Metal Forming has been to the standards and quality in all Tegral products. composites, factory assembled PIR and
mineral wool core composite panels. For further technical information on all
forefront of development with regard to
Our Standards This range presents the designer Tegral products please refer to the
roofing, cladding and flooring systems.
All manufacturing in Athy meets with a unique opportunity to objectively individual product brochures or
with the stringent requirements analyse the characteristics of the different alternatively contact our
Based in Athy, Co. Kildare, the Tegral Group
of Quality Assurance systems Technical Services Department.
consists of Tegral Building Products and systems and to select the best
to ISO 9001:2000 and ISO 14001 Tel: 00 + 353 (0) 59 86 40750
Tegral Metal Forming. Tegral Building solution for any building.
Environmental Management Standard. Email: metaltech@tegral.com
Products is Ireland’s largest manufacturer
or Sales Department
and distributor of roofing products and Our People Tel: + 353 (0)59 86 40740
Tegral Metal Forming Ltd. is a leading People really do matter at Tegral Metal
Email: metalsales@tegral.com
manufacturer and supplier of metal roofing Forming. Recently the company
and flooring systems for the proudly embraced and succeeded
construction industry. in achieving the “Excellence
Through People” award, Ireland’s
The comprehensive product range is national standard for human resource
designed to suit most applications in development.
modern commercial, industrial and
Our Industry Associates
agricultural construction. Over the years,
Tegral Metal Forming takes an active role
Tegral Metal Forming has developed an
in the promotion of the metal industry and
expertise in every aspect of metal is involved in the Roof Manufacturers and
systems application. Suppliers Association (RMSA) in Ireland,
the Metal Cladding and Roofing
Manufacturers Association (MCRMA)
in the UK and also the Irish Farm
Buildings Association.
1 2
DESIGNER’S ROOFING AND CLADDING GUIDE DESIGNER’S ROOFING AND CLADDING GUIDE
3
1
1 5
9
LPCB & FM approved 4 ComFlor ® Flooring Range
Insulated Panel Range
2
7 6
5
Built-Up Roofing and Flat Roof Deck Range
Wall Cladding Systems
2
9
Zeta Purlin Range
SolarWall™ 8
3 4
8
Superdeck Membrane-faced Complete Tegral Systems Range including the World's first CarbonNeutral building envelope through Confidex Sustain™ from Corus with Colorcoat® assessed systems. Flashings
Insulated Roof Panel 3 4
DESIGNER’S ROOFING AND CLADDING GUIDE Table of Contents
5. Firewall Systems 39
6. Acoustic Systems 57
8. Performance:
Structural Performance 83
Thermal Performance 93
5 6
DESIGNER’S ROOFING AND CLADDING GUIDE Tegral Product Range DESIGNER’S ROOFING AND CLADDING GUIDE Tegral Product Range
The choice of application system will be dictated by Metal roofing may be fixed to either steel (cold-rolled
the building type, structural frame, extent of galvanised or hot-rolled) or timber purlins. In addition,
cladding and aesthetic, internal design requirements. it may be fixed to profiled metal decking or timber
Metal systems are suited equally to both entire decking. Similar options exist for metal cladding with
building envelope enclosure and small-scale feature the addition of rainscreen application methods.
infill cladding panels. The following typical application methods are given for
®
The common feature in all applications is the need guidance purposes – other options can be discussed Tegral ALU-SEAM Tegral Seam-Loc
for a support element for the chosen metal product. directly with the Tegral Technical Services Department. Tegral CL5/1000 liner Tegral CL5/1000 liner
Tegral Trisomet
7 8
DESIGNER’S ROOFING AND CLADDING GUIDE Tegral Product Range
4 Green Credentials
Tegral Built-Up systems
are fully recyclable and in
addition offer the World's
first Cradle-to-Grave
Carbon Neutral Building
Envelope with Confidex®
Sustain from Corus.
9 10
DESIGNER’S ROOFING AND CLADDING GUIDE DESIGNER’S ROOFING AND CLADDING GUIDE
The specification of building materials is becoming This comprehensive assurance package applies to The Benefits of Tegral System Assurance:
increasingly complicated by the need to consider not
just aesthetic and structural qualities, but also
ALL Tegral Built-Up systems and covers
weatherproofing, structural integrity, thermal
The Tegral System Assurance package for our Built-
Up systems is backed by a full Irish-based technical
• Insert 3-D diagram of built up wall & roof with
bullet points to diagram.
energy efficiency, cost effectiveness, health and performance, airtightness, fire and acoustic
safety and sustainability. Tegral are pleased to protection and sustainability.
support team that is available to provide guidance
and advice on all aspects of compliance with the • System durability & Weatherproofing - Up to 40
years weatherproofed coating guaranteed
manufacture and supply a range of state-of-the-art latest building regulations, as well as environmental
roofing and cladding products that are
independently assessed across multi-performance
issues, design challenges and specification details. • Thermal Performance – Proven thermal
performance and assured compliancwith Energy
criteria to offer the specifier and building owner the Performance of Buildings Directive (EPBD).
highest possible levels of assurance.
• Airtightness – System design and assembly codes
of practice to optimise airtightness for assured
EPBD compliance.
11 12
DESIGNER’S ROOFING AND CLADDING GUIDE Tegral Product Range
00
COVER WIDTH 10
33
WIDE RIB R33
1000
COVER WIDTH
40 BROAD RIB R40
TH 800
COVER WID DEEP RIB R60
60
TH 410
48 COVER WID
TH 410
48 COVER WID
ALU-SEAM®
SEAM-LOC
13 14
DESIGNER’S ROOFING AND CLADDING GUIDE Tegral Product Range DESIGNER’S ROOFING AND CLADDING GUIDE Tegral Product Range
Wall cladding profiles from Tegral have a reputation This profile has a distinct half-round shape and
for proven weather protection, durability and fire compliments the growing trend for feature elevations
performance. Each profile can be used in a choice of and curved building forms. Ideal for large-scale
economical applications. The profile range is distinct projects, Arcline 40 maintains a strong visual impact
TM
and extensive and allows for the choice of even when viewed from a distance.
horizontal and vertical designs. The range includes:
Tegral Shadowline 47 TM
Tegral Fineline 19
A louvre-like profile with sharp lines, The most versatile profile in the range, this sinusoidal
Shadowline 47 provides strong contrast to flat wall
TM
Non combustible. 40
19 33
19
46
47
60
COVER WIDTH 1160
WP40 MINI RIB FINELINE 19 PL19 WIDE RIB C33 BROAD RIB C40 MID RIB C46 DEEP RIB C60 SHADOW LINE 47 ARCLINE 40
15 16
DESIGNER’S ROOFING AND CLADDING GUIDE Tegral Product Range
1050
COVER WIDTH
19 PL -19 Tegral HL600 Liner Tray
WIDE RIB
33-1000
PERF (20%)
HL600/130
130
HL600/130
PERF (36%)
Tegral CL5/1000 Liner Sheets
TH 600
COVER WID
17 18
DESIGNER’S ROOFING AND CLADDING GUIDE Tegral Product Range DESIGNER’S ROOFING AND CLADDING GUIDE Tegral Product Range
Trimapanel integrated solutions for the construction industry, Flashings are offered in a selection of pre-finished
finishes. Panel lengths up to 14m available. ®
Tegral Metal Forming offers a comprehensive array steel by Corus including Colorcoat HPS200 and
®
of metal flashings. The range is divided into five 'Colorcoat Prisma . Other products available include
® ®
The Flashings Team Brown , Kilkea Grey , Coolmine Grey, Ballitore Brown
property protection, all in one Suitable for use as a Firewall
Tegral Metal Forming has a dedicated Flashings and Woodstock Green.
product. Tegral Enviropanel™ is fully (60 minute insulation) to BS 476, RF Cover width 1000
recyclable and is suitable for use as Team that includes two manufacturing technicians Custom Designs
protecting against fire attack
a fire-rated partition. The product and a customer service professional. The Sales Team When it comes to manufacturing customised
from either side.
can also offer acoustic benefits and SF Cover width 1000 liaises closely with the Flashings Team and serve as flashings, the technicians at Tegral Metal Forming
provides effective sound reduction Fully recyclable and satisfies the conduit between the customer and have the experience and expertise to produce
Microrib
sustainable construction standards. manufacturing. Each member of the Flashings Team superior quality one-of-a-kind product. These include
or sound absorption.
has extensive product knowledge and is available to curved flashings, mitred corners, gutter corners and
Tegral Enviropanel™ mineral-wool Available with perforated internal face
to allow for acoustic absorption. provide information and support. louvres. Each product can be made to the exact
core panels are available in a Planked
Standard Selection requested specification in a wide range of girths,
choice of Colorcoat® pre-finished TF Cover width 1150
At Tegral Metal Forming our standard range of gauges and in an array of colours.
steel finishes.
Flashings is the result of over 25 years experience Note: Certain restrictions apply to 24 hour turnaround service.
and was created with the customer in mind. Please check with your customer service representative.
Trinsul
'For information on Tegral Composite Panels, see separate section 1 of this guide.
19 20
DESIGNER’S ROOFING AND CLADDING GUIDE Aesthetics
Roofing Profiles
All Tegral products are designed to provide the architecture, curved roofing is a growing trend.
correct combination of aesthetic appeal and function Tegral’s ALU-SEAM® standing seam can be used in
required of the finished building, whether planned complex convex or concave roof shapes while
by the building designer or imposed by local Wide Rib R33 and Fineline 19 are widely used for
planning requirements. feature barrel vault curves.
Tegral is pleased to be able to offer practical roofing
solutions that are design focused. In modern-day
Tegral Broad Rib R40 profile Tegral Mid Rib R46 profile
®
Tegral Deep Rib R60 profile Tegral AlU-SEAM profile
The Tegral range of Profiles can be applied vertically, Tegral Fineline 19 profile TM
Tegral Mid Rib C46 profile Tegral Shadowline 47 profile
horizontally and diagonally providing excellent design
flexibility. In addition, Sinusoidal and Trapezoidal can
be combined on different cladding areas creating
extra interest.
Shadowline 47 , Arcline 40 and ALU-SEAM® profiles are
TM TM
Tegral PL 19 profile Tegral Deep Rib C60 profile Tegral Arcline 40 profile
Tegral Fineline 19
Tegral Wide Rib C33 profile Tegral Broad Rib C40 profile
23 24
DESIGNER’S ROOFING AND CLADDING GUIDE Aesthetics DESIGNER’S ROOFING AND CLADDING GUIDE Aesthetics
Tegral Enviropanel®TF Micro Rib Our range of liner sheets includes 6 different profiles
®
Tegral Enviropanel , Trisomet, and Trimapanel are which can be combined with a wide range of
modular in appearance and work well in high-tech coatings, to provide the required internal finish to a
construction or urban style office buildings. These building. The use of our structural liner tray
products also contrast with curtain wall glazing and eliminates secondary steel and creates an
profiled cladding. The roof space can also vary unobstructed ceiling or internal wall.
considerably from ultra low pitch with high-level
parapets to steep-pitch feature roofs.
Tegral PL 19 profile Tegral Mini Rib profile
Trimapanel
25 26
DESIGNER’S ROOFING AND CLADDING GUIDE Aesthetics DESIGNER’S ROOFING AND CLADDING GUIDE Aesthetics
Weight (kg/m2
Gauge (mm)
Minimum
Minimum
Minimum
Material
categorised into sinusoidal or trapezoidal shapes. Products from Metal Sheet- Specification for self-
supporting products for steel, aluminium and
stainless steel sheet. Cover width 990.6
19
Fineline 19 S 0.7 6.81 20 (h), 30 (p) 1000 10
A 0.9 3.05 20 (sa/ca), 25 (ma) 1000 10
76.2
27
33 Wide Rib R33 S 0.7 6.75 40 (h), 50 (p) 400 4
A 0.9 3.02 40 (sa/ca), 45 (ma) 400 4
200 127.5
Rib Crown (top flange) Pitch ALU-SEAM A 0.9 3.75 30 (sa/ca), 35 (ma) 7000 1.5
convex
Cover width 410
48
205
Key ca - Coated aluminium
S - Steel ma - Metallic coated alum.
A - Aluminium sa - Stucco embossed
Note: Profiles are subject to IS EN 508 -1 tolerances ®
27 28
DESIGNER’S ROOFING AND CLADDING GUIDE Aesthetics DESIGNER’S ROOFING AND CLADDING GUIDE Aesthetics
Weight (kg/m2
Weight (kg/m2
Gauge (mm)
Gauge (mm)
Minimum
Minimum
Minimum
Minimum
Material
Material
Cover width 300
Cover width 1160
WP 40 S 0.7 7.50 60 (h), 70 (p) N/A j Mini Rib S 0.7 5.73 20 (le), 25 (h) N/A
40 107 145 8
Cover width 1000 Wide Rib C33 S 0.5 4.82 40 (h), 50 (p) 400 j
128
27 S 0.7 6.75 40 (h), 50 (p) 400 Cover width 1000 Wide Rib 33C S 0.4 3.88 40 (le/h) 350
33 33
A 0.9 3.02 40 (sa/ca), 45(ma) 200 S 0.7 6.75 40 (le/h) 350
200
A 0.9 3.03 40 (sa/ca) 350
Cover width 1000
Broad Rib C40 S 0.5 4.82 40 (h), 50 (p) 350 j
31
40 S 0.7 6.75 40 (h), 50 (p) 350 38.50 60
HL600/130 S 1.00 13.08 N/A
242 333.3 A 0.9 3.02 40 (sa/ca), 45 (ma) 400 S 0.75 9.81 N/A
130
Cover width 900
120
Mid Rib C46 S 0.5 4.82 55 (h), 65 (p) 400 j Cover width 600
52
Shadowline 47 S 0.7 6.56 70 (h), 80 (p) N/A
TM
150 100
47 A 0.9 3.36 70 (sa/ca), 80 (ma) N/A
29
Note: Profiles are subject to IS EN 508 -1 tolerances h - Colorcoat HPS200 p mill aluminium
®
29 30
DESIGNER’S ROOFING AND CLADDING GUIDE Aesthetics
Composite Panels
Weight (kg/m2
gauge (mm)
Material
Internal
Mineral wool core Insulation
37 250 170
®
Enviropanel RF S 0.4 0.63 24.6 (120mm thickness)
Cover width 1000
32 200 120
Tegral Trimapanel
®
31 Tegral Enviropanel TF 32
DESIGNER’S ROOFING AND CLADDING GUIDE Aesthetics
Trinsul
design goals
Tegral Alu-Seam
35 36
DESIGNER’S ROOFING AND CLADDING GUIDE DESIGNER’S ROOFING AND CLADDING GUIDE
Seam-loc
Maximum sheet lengths Minimum roof pitch Colorcoat HPS 200 steel. Galvalloy NOTE: Alu-Seam® 101 and 102 extruded aluminium
• 12m without additional • 11/2º - continuous sheet ridge substrate to BS EN 10326 : 2004 clips are also used for the Seam-loc system in place
handling or carriage charge. to eaves. S220GD+ZA265, nominal thickness of the steel clip, where the roof is curved.
0.7mm, with Corus standard colour
• 26m subject to feasibility of site • 11/2º - continuous sheet eaves
Colorcoat finish to the external
access and carriage and to eaves. (curved roof).
face and light grey high
handling costs.
• 3º - sheet with end-lap* performance polyester to the
Longer lengths than 26m are reverse. Design minimum yield
• 3º - sheet with penetrations*
possible but these are subject to stress 220 N/mm2.
*
direct enquiry. unless welded
Self-weight of Seam-loc profile
This information may be updated The minimum roof pitch 8.45kg/m2.
subsequent to the publication of must be achieved at sheet
this manual. ends. When determining the
roof pitch, the loading and
deflection of the sheet must
be taken into account.
37 38
DESIGNER’S ROOFING AND CLADDING GUIDE Fire Performance
the right application……secures safety, minimises risk and fire risk associated with the building. In a landmark
case in the UK High Court in March 2003, an
building services. The second element is oxygen
which of course is present in all buildings and the
is the responsibility of every conscientious designer”. insurance company succeeded in winning the first
liability judgement against negligent architects who
third is any material that can fuel the fire.
Consideration of the elements of the fire triangle
inappropriately specified the use of combustible will impact on the fire safety requirements of
insulated panels. Now, more than ever the manner the building.
in which elements of building construction perform IGNITION
in the event of a fire is of prime concern to the
designer, the occupant, the building owner and the
building insurance company.
MATERIAL OXYGEN
Twin Skin Site assembled Mineral Wool core PIR core composite Standing
system composite composite panel panel seam roofing
39 40
DESIGNER’S ROOFING AND CLADDING GUIDE Fire Performance DESIGNER’S ROOFING AND CLADDING GUIDE Fire Performance
The purpose of Building Regulations is to ensure the health B4 - External Fire Spread
Fire performance - The Specifier’s choice and safety of people in or about the building.
The main requirements are:
1) The external walls of the building shall resist
the spread of fire over the walls and from one
building to another, having regard to the
a) To provide a safe means of escape for the
height, use and position of the building.
building occupants by preventing internal
fire spread. 2) The roof of the building shall resist the spread
Essentially, the issue concerns the fire performance of the means that standard twin-skin glassfibre or mineral wool b) To prevent the spread of fire to neighbouring of fire over the roof and from one building to
individual metal system’s insulation core. The new European insulated built up systems and mineral wool composite or property. another, having regard to the use and position
method of classification of fire performance EN 1350-1, site assembled composite panels are acceptable per se. c) To prevent an external fire from setting fire to of the building.
categorises building materials into classes based upon their the building.
LPC Fire resistance standard:
time to flashover, from A1 to F. In the case of mineral wool d) To provide access for the Fire Brigade.
Other insurance companies refer to the Loss Prevention The external walls of the building should have the
and glasswool, these insulation materials achieve Euroclass
Council Design Guide for the Fire Protection of Building Generally metal roof cladding has to limit the spread of fire appropriate fire resistance given in Table A1, Appendix A
A1, the lowest possible fire-risk classification.
2000. Section 2.2 of this guide states. on its internal liner face, prevent the spread of fire through of TGD B.
A great deal of confusion reigns in the area of fire any cavity, and resist the spread and penetration of fire on
2.2 Contribution to fire growth This table stipulates specific provisions of test for fire
performance specification of metal cladding systems. This its weathersheet side. Roofs do not usually need to provide
The main objective in relation to all elements of resistance of elements of structure stating required
has increased considerably in recent years and has been any period of fire resistance.
construction, including roofs, is that they should not method of exposure, integrity and insulation periods
caused by several factors.
significantly contribute to the growth and spread of fire, European Standard test methods have now been published, based on the distance from a relevant boundary.
1. Most companies that supply insulated systems only offer either internally or externally. In this respect it is important and it is now possible to claim compliance with Document B
one type of system. This had led directly to the fire that the complete building design is analysed to ensure Table A1 refers to Table A2 which in turn gives a
using either the original BS 476 tests or the new
performance characteristics of generic materials and that as a result of its behaviour in a fire no element of fire specific breakdown of fire resistance periods for buildings
European tests.
systems becoming an issue of competitive product benefit protection will be compromised. in certain purpose groups, building heights and whether
and thus propaganda, rather than an objective study of The Building Regulations TGD B provides guidelines on sprinklered or not.
This is equally applicable to internal non-structural features acceptable forms of fire resistant structures encompassing
requirement. The latter would be far more useful to For example, an external non-loadbearing wall on an
such as linings, ceilings and partitioning systems, thereby construction, material performance, means of escape and
specifiers. Tegral Metal Forming supplies a range of industrial unit up to 20m from ground level requires a
reducing the potential fire spread and growth. appropriate active fire control techniques.
system options. minimum fire resistance period of 90 minutes (non-
This should be achieved by use of materials which are: These are categorised in the following requirements: sprinklered) with an insulation period of 15 minutes.
2. Insurance concerns frequently drive decision making
rather than regulatory requirement. Experience has proven (a) non-combustible or of limited combustibility (see B1 – Means of escape All certified/assessed Tegral Twin-Skin FireWall systems
that insurance requirements are more difficult to pin down Appendix 3A1 of Part 3) or, if timber, they comply B2 – Internal Fire Spread (linings) and certain Tegral Trisomet and Trimapanel Insulated
than Building Regulations; also they may change in time with the fire resistance requirements given in this B3 – Internal Fire Spread (structure) panels achieve 4 hours integrity and 15 minutes
and with different building use. Design Guide (see Tables 2.1 and 2.2); B4 – External Fire Spread insulation and therefore would satisfactorily meet this
3. The insurance industry reaction to several disastrous fires (b) Loss Prevention Certification Board (LPCB) B5 - Access & Facilities for the Fire Service criteria.
in food processing factories using polystyrene cored panels approved products which include combustible All of these stipulations require close design integration in External Surfaces:
as internal partitions and cold room enclosures, materials and have been tested and satisfy the order to establish effective building fire containment systems The external surfaces of walls should meet the provisions
exacerbated by the events of 9/11, had the effect of over requirements in accordance with LPS 1181 and and suitable evacuation procedures. laid out in Table 4. 1 of Requirement B4.1. 4. A brief
sensitising the entire industry. Whilst these things are not have thereby been shown not to make a summary of this diagram is tabulated below:
related to external cladding using PIR-core panels, they significant contribution to fire growth; Whilst for the purpose of this brochure it is impractical to
have had a profound effect on attitude to them. cover all the conditions contained within this document, Provisions for external surface of walls
All Tegral Twin-Skin Systems, mineral wool core composite Requirements B2 and B4 are the most relevant when
Tegral Metal Forming offer metal cladding solutions that or site-assembled composite panels meet the Building Distance from Classification
considering the use of steel cladding systems. The following
Height Boundary
include Twin-Skin systems, site assembled composites, PIR- requirements of (a) above. information has been produced as a guide to highlight some
core composite panels and mineral wool panels. This of the basic criteria. <20m <1m 0
presents us with a unique opportunity to give unbiased Tegral Trisomet PIR-insulated panels meet the
<20m >1m No provision
advice and there follows an analysis of the characteristics requirements of (b) above, for roof applications and B2 - Internal Fire Spread (linings)
of the different systems. certain wall applications. (1) To inhibit the spread of fire within the >20m <1m 0
In addition, there are other benefits to the avoidance of all building, the internal linings shall:- >20m >1m For the initial
Fire Insurance and Tegral Systems (a) resist the spread of flame over their surfaces; 20m index ‘I’
Typically these systems use metal components and glass or combustible materials in cladding systems. A common
and should not
mineral wool insulation, which wholly or partly fills the cause of fire in buildings is vandals setting fire to material exceed 20.
such as timber pallets outside the building. The heat and (b) have, if ignited, a rate of heat release which is
void between an inner and an outer metal sheet. The reasonable in the circumstances. All Tegral Areas above 20m
insulation may be of two types, glass fibre or rock fibre. flame from this source combusts with the outer surface the classification
igniting insulation in the wall construction and then cladding products manufactured from Corus
should be 0
Both insulation types are non-combustible to BS476 Part 4. organic coated steel meet Classification 0.
Metal systems using either forms of insulation are spreading through the building. If the materials used in
the cladding and roofing system are non-combustible, a A description as to how this classification is All Tegral cladding products manufactured from Corus
intrinsically fire safe. obtained can be found within the British
lower fire risk for the property inevitably follows. organic coated steel meet Classification 0. A description
Twin-Skin systems (or composite panels) using these Standard 476 section of this brochure as to how this classification is obtained can be found
materials are thus usually acceptable to insurers without Statutory Requirements and Tegral Systems within the British Standard 476 section of this brochure.
The manner in which all elements of building construction Classification of Linings
further qualification.
perform in the event of fire is of prime concern of the Location Class External Wall Construction:
The two principal reference authorities for fire insurance designer, the accupant, the building owner and the Small rooms of area not 3 It must be noted that even though the provisions for
assessments are Factory Mutual (FM) and the Loss building insurance company. Profiled metal cladding more than 4m2 in a external surfaces may have been satisfied, on buildings
Prevention Council (LPC). constructions must therefore conform to specific residential building and 3m2 that are in excess of 15m above ground level the
requirements which are defined in the Building in a non-residential building insulation material used in the external wall construction
Factory Mutual (FM Global) should be of limited combustibility.
Regulations Technical Guidance Document B - Fire Safety. Other rooms. Circulation 1
Factory Mutual highlight their preference for non-
They may also have to comply with other spaces within dwellings
combustible materials and indeed only constructions All insulation specified for use within Tegral FireWall
requirements defined by building insurance
containing combustibles have to be FM Approved, which Other circulation spaces, 0 systems can be deemed ‘non-combustible’
organisations, such as the Loss including the common area in accordance with BS476 Part 4 and would
Prevention Council (LPC). of flats and maisonettes therefore meet the criteria of this stipulation.
41 42
DESIGNER’S ROOFING AND CLADDING GUIDE Fire Performance DESIGNER’S ROOFING AND CLADDING GUIDE Fire Performance
British Standard 476 provides an acceptable framework for BS476 Part 6: Methods of Test Point of failure is deemed when the mean temperature on the Trisomet PIR-Core Composite Panels
meeting these requirements within Ireland and the U.K. and for Fire Propagation for Products unheated side of the construction exceeds 140°C above ambient Whilst there is a long history of minimal fire risk presented by
focuses on test related physical measurement in order to This test determines the contribution a material makes to the or when the temperature of any surface point across the polyurethane composite panels used externally, as shown
establish fire rated performance for steel cladding systems. fire and is measured in terms of heat contributed over a period unexposed face reaches 180°C above the initial ambient. above in the excerpt from the LPC Design Guide, insurers now
of twenty minutes. This is expressed as an index of will frequently demand that sandwich panels show
Reference is made to this standard in TGD B sections B2 to B4 - Tables A1 and A2 in Appendix A of TGD B stipulate actual
performance ‘I’ together with sub-indices i1, i2 & i3 which are compliance to LPS1181 (or in the case of Factory Mutual carry
Internal and External Fire Spread. requirements which can vary from 1/2 hour integrity to 2 hours.
assessed from empirical formulae. These sub-indices relate to FM Approval). Compliance with either of these two test
Reaction to Fire heat contributed over shorter time periods. A comprehensive range of Tegral FireWall cladding systems have regimes is dependent on a number of factors, most
In Approved Document B, the most favourable performance in been developed and certified/assessed to BS476 Part 22. These importantly the panel’s foam formulation, the side and end
Organic coated steel Tegral cladding products with for example
reaction to fire is given by a Class O spread of flame rating to offer a range of insulation performance from 15 minutes to the lap details and the construction details. Polyisocyanurate (PIR)
Corus HPS200® and Lining Enamel type finishes have an index
the Building Regulations. This combines results from BS476 more stringent 1 hour requirement laid down for is a version of Polyurethane; to qualify as PIR the ratio of
‘I’ not exceeding 12 and a sub-index i1 (heat contributed in the
Part 6 : Methods of test for Fire Propagation for Product and partitional/separating walls. isocyanate to polyol must be greater than 1.8. However not all
first 3 minutes) not exceeding 6.
BS476 Part 7 : Methods for Classification of the Surface Spread PIR formulations perform the same in a fire and so exactly the
These are shown in the Tegral FireWall system selector section of same formulation as that tested must be used in reality, for
of Flame. Alternatively a Class O may be shown by Euroclass B BS476 Part 7: Methods for Classification of the
this brochure. A quick reference table has also been included. compliance to LPS 1181. In fact, where a complying wall
or better to EN1350-1. All Tegral Cladding Profiles Surface Spread of Flame of Products
meet Class 0 requirement. This test grades material into classes 1 to 4 according to the Updating Fire Requirements construction is required the entire panel and fixing
rate of flame spread across it’s surface. All Tegral cladding As a result of the ongoing programme for the revision specification must also be in accordance with the
Fire Resistance specification used for the test.
products produced from Corus organic coated steel achieve of British standards it is inevitable that some will be withdrawn
The regulations demand that certain walls, in
Class 1 - the highest grade offering the best resistance to yet will still remain being cited by the Building Regulation
addition to providing a satisfactory performance in reaction to Tegral offer the Trisomet system with necessary FM
spread of flame. Approved Documents. It is therefore recommended that designers
fire, must show a fire resistance performance in terms of and LPC approval.
review standards and approved documents for current status.
integrity and insulation measured in minutes. Examples of The Building Regulations have a higher Classification defined
Loss Prevention Certificate Board LPCB Certificate No. 460a
these are, external walls constructed on or near boundaries, or as Class 0, which combines results from BS476 Parts 6 and 7. Fire Resistance and Tegral Systems Issue 5. (Roof panel only).
walls used as partitions. These constructions have to be tested A Class 0 surface must have a Class 1 result from BS476 Part 7 Twin-Skin Cladding;
to BS476 Part 22 : Methods for the Determination of the Fire and a maximum index ‘I’ of 12 and maximum sub-index i1 The combination of Class 0 profiled metal external FM Approval: Project ID: 3016409 Class 4880, 4771 for wall
Resistance of Non-load Bearing Elements of Construction. value of 6 from BS476 Part 6. cladding and Internal lining sheets together with the use of non- and roof panels.
These requirements do not apply to roofs. combustible glass or mineral wool insulation have been tested to
Therefore, Tegral cladding has a finish that achieves Class 0 Decision Tree for Wall Cladding or Insurer
BS 476: Part 22 for fire resistance. Independently certified by
BS476 is the recognised standard referred to in the Building spread of flame in accordance with the Building Regulations. apporved Insulated Panel Specification
Warrington Fire Research Centre Ltd, Tegral Twin-Skin Firewalls
Regulations and provides a framework for meeting fire
BS476 Part 11: Method for assessing the meet the requirements for integrity and insulation to suit and
performance requirements within Ireland and the U.K.
Heat Emission from Building Materials variety of system applications. Insurance company requirements?
This standard concentrates on test related physical A material which is deemed ‘non-combustible’ in accordance
Trinsul Site assembled composite
measurement in order to establish the fire rating performance with BS476 Part 4 automatically complies with the No Yes
Using high density rock fibre insulation this system offers
of elements/constructions. The most relevant in relation to requirements laid down for limited combustibility in accordance
excellent fire performance characteristics. Thus in addition to the
Tegral organic coated steel cladding products/systems can be with BS476 Part 11.
general attributes described above for Twin-Skin systems, the
highlighted as follows:–
This standard adopts a similar test methodology to BS476 Part Trinsul system has been tested and assessed to BS476 Part 22 to
BS476 Part 3: 4 but uses a different method for the calculation of results. provide 60 minutes insulation and 4 hours integrity – making it
External Fire Exposure Roof Test suitable for many boundary and partition applications.
All insulation products specified for use within Tegral FireWall Any Tegral Use Insurer Use Tegral
Roofs are graded according to the resistance they offer to
systems achieve ‘non-combustible’ classification in accordance Tegral Enviropanel® Mineral wool core composite panel metal Twin Skin
external fire (e.g. from an adjacent building or compartment). Approved
with BS476 Part 4 and would therefore meet the limited The use of mineral wool as an insulating core for a composite wall cladding system
This is measured in terms of penetration and flame spread. Tegral
combustibility classification. panel confers upon it exceptional fire properties. The use of non system
The Irish and U.K. Building Regulations designate pitched roofs Composite
combustible materials makes these panels generally acceptable to
using profiled sheets produced from galvanised steel or organic BS476 Part 22: Methods for determination of the Fire
insurers. However The Tegral Tegral Enviropanel® system also Panel
coated steel as Classification AA, the highest designation Resistance of non-loadbearing elements of Construction
been successfully tested to LPS1181 (Loss Prevention Certificate
possible. Therefore, it can be satisfied that roofs constructed This standard concerns itself with the exposure of fire on one
Board LPCB Certificate No. 460 A Issue 5).
with Tegral profiles in accordance with manufacturer’s or both faces of the wall construction, the growth of which is
instructions will achieve this rating. designed to simulate a real fire occurrence i.e. in terms of The Tegral Enviropanel® system has also been successfully tested
speed of temperature rise, flashover point and eventual to BS476 Part 22 for fire resistance and provides 60 minutes Statutory requirement
Note: This standard has been withdrawn by the British
temperature peak. insulation and integrity.
Standards Institution but continues to be cited in the Building
Regulations. The relevant test method has therefore been Definitions of fire resistance are met in the context Tegral Trisomet and Trimapanel PIR insulated Panels
included as an annex within BS5427: 1996 Code Of Practice for of two criteria: Tegral insulated Trisomet and Trimapanel PIR core insulated panels is fire resistance required?
the use of Profiled sheet for roof and wall cladding offer Loss Prevention Certificate Board (LPCB) approval under
on buildings. Integrity: No Yes
certificate numbers 460a/12 (Trisomet Vertical or Horizontal 60mm/
The time taken before failure of the wall system to
80mm/100mm), and 460a/13 (Trimapanel 70mm & 90mm).
BS476 Part 4: satisfactorily prevent the passage of flames and hot gases in
Non-Combustibility accordance with the test procedures laid down in this standard.
Test for Materials
All insulation products specified for use within Tegral Profiles Insulation:
FireWall systems achieve ‘non-combustible’ classification and This must be non-combustible and restrict the transmittance of Use Tegral
therefore meet the requirements laid down within TGD B, heat from the source of the fire to the unexposed face of the Any Tegral Tegral Twin
Composite
Section B4, External Wall Construction. wall construction. metal Skin System
Panel fire
wall cladding fire tested to
tested to
system BS476 Part 22
BS476 Part 22
43 44
DESIGNER’S ROOFING AND CLADDING GUIDE Fire Performance DESIGNER’S ROOFING AND CLADDING GUIDE Fire Performance
Tegral Fire Wall System Selector 60 minutes Insulation 4 Hour Integrity Fire Wall
Construction Fire resistance Insulation Exposed Boundary Page WFRC* Warrington Fire Research Centre Number C127164.
Description Orientation Type period (stability criteria face distance No. certificate
Trinsul Mineral Wool Fire Wall (vertical cladding/liner outside rail/horizontal cladding rails)
and integrity (mins.) (m) No.
-hours)
Trinsul Fire Wall Vertical Outside rail 4 60 Either within 1m 36 C127164 Tegral Trinsul outside rail cladding Insulation
face 80kg/m3 nominal density profiled
system has a 1 hour fire
rockfibre Trinsul insulation board.
Trinsul Fire Wall Horizontal Outside rail 4 60 Either Within 1m 37 C113875 resistance from either direction
Minimum thickness to achieve
face when fixed within 1 metre of 0.27W/m2K ‘U’ value for fire
relevant boundary. resistance.
Twin Skin Fire Wall Vertical Outside rail 4 15 Inside 1m or 35 C107677
with Instaloc 40 face more
Spacer System &
Glassfibre Quilt
Liner sheet
Twin Skin Fire Wall Vertical Outside rail 4 15 Inside 1m or 39 C107675 Tegral Colorcoat® steel liner sheet
with Instaloc 40 face more profile. 0.4/0.7mm gauge.
Spacer System &
Mineral Wool quilt
Structural Liner Tray Vertical Liner Tray 4 15 Inside 1m or 41 C54353 Tegral cladding rails.
Fire Wall face more The rail is not fire protected but a
Mineral Wool quilt
facility for expansion is required
LPC (i.e. slotted fixing holes).
Structural Liner Tray Vertical Liner tray 4 60 Either Within 42 C80289
Fire Wall face 1m Tegral Trinsul meets fully the
Mineral Wool quilt requirements of part 2.2 of the T1001
Outer Cladding
LPC Design Guide for the Fire 1 hour
Insulation
Twin Skin Fire Wall Horizontal Inside rail 4 15 Inside 1m or 43 C118450 Tegral Colorcoat® steel cladding
Protection of Buildings 2000. 4 hour Integrity
Glass fibre face more Rockfibre
profile. 0.5/0.7mm gauge.
Trinsul
Fire Wall
Note; Please see page 52 for General Construction Requirements applicable to all systems.
45 46
DESIGNER’S ROOFING AND CLADDING GUIDE Fire Performance DESIGNER’S ROOFING AND CLADDING GUIDE Fire Performance
60 minutes Insulation 4 Hour Integrity Fire Wall 15 minutes Insulation 4 Hour Integrity Fire Wall
Warrington Fire Research Centre Number C113875 Warrington Fire Research Centre Number C107677
Trinsul Mineral Wool Fire Wall (horizontal cladding/liner outside rail/horizontal cladding rails) Twin-Skin system Fire Wall with Instaloc 40 Spacer System & Glassfibre Quilt (vertical cladding /
liner outside rail / horizontal cladding rails)
Tegral Trinsul outside rail cladding Insulation This system is intended for use Insulation
system has a 1 hour fire 80kg/m3 nominal density profiled as an external wall, sited at Glassfibre insulation quilt, minimum
rockfibre Trinsul insulation board. least 1 metre from a relevant thickness 160mm. 10kg/m3 nominal
resistance from either direction
Minimum thickness to achieve density. U-value 0.27 W/m2K.
when fixed within 1 metre of boundary. It is not suitable for
0.27W/m2K ‘U’ value for fire
resistance.
partitions.
relevant boundary. Liner Sheet
43 44
DESIGNER’S ROOFING AND CLADDING GUIDE Fire Performance DESIGNER’S ROOFING AND CLADDING GUIDE Fire Performance
15 minutes Insulation 4 Hour Integrity Fire Wall 15 minutes Insulation 4 Hour Integrity Fire Wall
Warrington Fire Research Centre Number C107675 Warrington Fire Research Centre Number C107670
Twin-Skin system Fire Wall with Instaloc 40 Spacer System & Mineral Wool Quilt Twin-Skin system, Fire Wall with Mineral Wool or Glassfibre Quilt Insulation
(vertical cladding / liner outsider rail / horizontal cladding rails) (vertical cladding / liner inside rail / horizontal cladding rail)
This system is intended for use Insulation This system is intended for use Insulation
as an external wall, sited at least Rockfibre insulation quilt, as an external wall, sited at least Rockfibre 23kg/m3 nominal density or
1 metre from a relevant boundary. minimum thickness 160mm. 1 metre from a relevant boundary. glassfibre 10kg/m3 nominal density,
23kg/m3 nominal density. minimum thickness 180mm.
It is not suitable for partitions. It is not suitable for partitions.
U-value 0.27 W/m2K U-value 0.27 W/m2K
Assessment of fire resistance refers Assessment of fire resistance refers
to cladding system which must be Liner Sheet to cladding system which must be Liner Sheet
supported at base or by a fire rated Tegral Colorcoat® steel liner sheet supported at base or by a fire rated Tegral Colorcoat® steel liner sheet
eaves beam. The assessment refers to profile 0.4/0.7mm gauge. eaves beam. The assessment refers profile 0.4/0.7mm gauge.
49 50
DESIGNER’S ROOFING AND CLADDING GUIDE Fire Performance DESIGNER’S ROOFING AND CLADDING GUIDE Fire Performance
15 Minutes Insulation 4 Hour Integrity Fire Wall 60 Minute Insulation 4 Hour Integrity Fire Wall
Warrington Fire Research Centre Number C54353 Warrington Fire Research Centre Number C80289
Structural Liner Tray with Mineral Wool Insulation (vertical cladding onto liner tray) Structural Liner Tray with Mineral Wool Insulation (vertical cladding onto liner tray)
Liner Tray
51 52
DESIGNER’S ROOFING AND CLADDING GUIDE Fire Performance DESIGNER’S ROOFING AND CLADDING GUIDE Fire Performance
15 Minute Insulation 4 Hour Integrity Fire Wall 15 Minutes Insulation 4 Hour Integrity Fire Wall
Warrington Fire Research Centre Number C118450
Warrington Fire Research Centre Number C107659
Twin-Skin system Fire Wall & Glassfibre Quilt Insulation
Twin-Skin system Firewall, Mineral Wool Insulation
(horizontal cladding / liner inside rail / vertical cladding rails)
(horizontal cladding / liner inside rail / horizontal sheeting rails)
This system is intended for use Insulation Strip This system is intended for use Cladding Rail
as an external wall, sited at least Glass wool insulation quilt, 600mm as an external wall, sited at least Tegral Cladding rails to be 150mm
1 metre from a relevant boundary. width, minimum thickness 100mm. 1 metre from a relevant boundary. minimum for 160mm insulation.
It is not suitable for partitions. 10kg/m3 nominal density. The rail is not fire protected so a
It is not suitable for partitions.
Assessment of fire resistance refers facility for expansion is required.
Assessment of fire resistance refers
to cladding system which must be (i.e. slotted fixing holes). For thicker
Liner Sheet to cladding system which must be insulation increase rail depth
supported at base or by a fire rated
Tegral Colorcoat® steel liner sheet supported at base or by a fire rated accordingly.
eaves beam. The assessment refers to profile 0.4/0.7mm gauge. eaves beam. The assessment refers
non-loadbearing walls. The cladding Top Hat
to non-loadbearing walls.
system carries no vertical load other Cladding Rail 1.60mm min. gauge galvanized steel
than its own dead weight. The cladding system carries no top hat section min. 45mm deep by
Tegral cladding rails. The rail is not
Installation of this system to be fire protected so a facility for vertical load other than its own Tegral Metal Forming. To be fixed with
in accordance with Building expansion is required (i.e. slotted dead weight. self drilling/self tapping fasteners, 2
Regulations TGD Part B (Fire Safety) fixing holes). Installation of this system to be at each sheeting rail.
in accordance with Building
Outer Cladding Outer Cladding
Regulations TGD Part B (Fire Safety)
Tegral Colorcoat® steel cladding Tegral Colorcoat® steel cladding
Galvanised Steel Strap
profile 0.5/0.7mm gauge. Laps profiles 0.5/0.7mm gauge.
50mm x 0.9mm galv. steel straps
stitched at 300mm max. centres
screw to fixed rails and spaced at
Construction Notes
1200mm centres Insulation
Insulation All fixings and components to be steel.
Glass wool insulation quilt 160mm foil faced rockfibre. All joints in the insulation to be
Air Gap
minimum thickness 160mm, (WFRC number C43554) or 160mm overlapped by 100mm and aluminium
30mm minimum air gap between
10kg/m3 nominal density glassfibre, 10kg/m3 nominal density. pins used to prevent joints from
insulation and inner face of liner sheet.
U-value 0.27 W/m2K 'U-Value: 0.27W/m2k separating. Fix insulation to rails in
T1003
accordance with insulation
15 minutes
Liner Sheet Insulation
1 hour Construction Notes
4 hour manufacturers
Integrity recommendations (note
Integrity All fixings and components to be Tegral Colorcoat steel liner Quilt Insulation
that the cladding sheet does not pin
Trinsul Double Skin
steel. All outer sheet side laps sheet profile Fireinsulation
Wall to rails in this system).
must be stitched at not more than 0.4/0.7mm gauge. (Horizontal)
Outer sheet to be stitched at 450mm
300mm centres. centres. Liner sheet does not require
Liner sheets to be stitched at stitching when rockfibre insulation is
300mm centres used, otherwise to be stitched at
300mm
53 54
DESIGNER’S ROOFING AND CLADDING GUIDE Fire Performance DESIGNER’S ROOFING AND CLADDING GUIDE Fire Performance
Part 4: 1970(1984) - Non Combustibility Test for B2 Internal Fire Spread (Linings)
Please contact Tegral Technical
Materials Part 6: 1989 - Methods of test for Fire
Services Department for B3 External Fire Spread (Structure)
Propagation for Products.
information on the insulation
B4 External Fire Spread
thickness needed for this Part 7: 1987 - Methods for Classification of the Surface
system to meet the Spread of Flame of Products B5 Access & Facilities for the Fire Service
requirements of the Building
Part 11: 1982 - Method for assessing the Heat Emission
Regulations Draft TGD Part L.
from Building Materials THE LOSS PREVENTION COUNCIL
The LPC Design Guide for the Fire Protection
Part 22- 1987 Methods for determination of the Fire
of Buildings 2000
Resistance of non - loadbearing elements of Construction
55 56
DESIGNER’S ROOFING AND CLADDING GUIDE Acoustic Performance
When something vibrates it creates waves of In the case of commercial or industrial buildings,
pressure which are carried through a medium such Tegral profiled metal roofing and cladding systems
as air or water as sound waves. The greater the can provide options for both Sound Absorption and
pressure created by the waves then the louder the Sound Reduction, to allow for noise control
sound. The greater the speed of the vibration then measures to meet Health and Safety and
the higher the frequency of the sound. Sound is Environmental Health regulations.
measured using decibels (dB).
General principles
There are generally four ways to reduce the extent
of noise heard by a receiver Acoustic Design
Metal cladding systems offer effective acoustic
1. Reduce the noise at source.
systems, to provide acoustic reduction, absorption or
2. Increase distance from source - as sound
both. However, actual priorities with regard to noise
waves spread out from a source, provided
control on any given project must be determined as
there are no reflections, they gradually
providing sound absorption will reduce the potential
decay.
for sound reduction and advice from acoustic
3. Use sound absorption - sound pressure
consultants may be required.
waves can be absorbed by open structured,
textured or fibrous material. In contrast, Sound Absorption
hard smooth surfaces will reflect sound and Sound Absorption (i.e. the damping of reverberant
have an adverse effect on the acoustics sound that would normally reflect back from smooth
inside a building because multiple hard internal surfaces) can be provided by the use of
reflections increase the internal sound Tegral perforated liner sheets, in conjunction with
level. Sound which is relected back into a suitable mineral wool insulation material.
building is referred to as Reverberant
(Note: Where perforated liners are used, a separate vapour
Sound. Sound absorption may therefore
control layer must be provided. This must be fully sealed at
be used to reduce noise levels within
all junctions and at rooflights to ensure that the
a building.
construction meets air tightness requirements).
4. Use sound insulation - the reduction in
noise levels provided by walls, roofs, Sound Reduction
windows etc. is generally referred to as Sound Reduction is a measure of the reduction in
sound reduction or sound insulation. sound level of noise escaping from a building. Tegral
Laboratory testing can accurately roofing or cladding systems are very effective at
measure the sound transmitted through providing sound reduction, as they can incorporate
an assembly. The sound reduction proven mineral wool acoustic insulation, combined
or insulation provided by the assembly with the relative high density of the metal internal
may then be referred to as the Sound liner and external cladding sheets.
Reduction Index (SRI). Tegral Acoustic Systems
“Tegral provides options for both Sound Absorption and WALL Tegral offer a wide range of acoustic systems.
The following examples indicate the most typical
Sound Reduction, to allow for noise control measures to applications. Variations in choice of metal profile
NOISE and insulation specification can be accommodated.
meet Health and Safety and Environmental Health
SOURCE
Please contact Tegral Technical Services Department
for further information.
TRANSMISSION
regulations”.…..
REFLECTION
(REVERBERATION)
ABSORPTION
57 58
DESIGNER’S ROOFING AND CLADDING GUIDE Acoustic Performance DESIGNER’S ROOFING AND CLADDING GUIDE Acoustic Performance
steel outer sheet Enviropanel Composite panel with plain liner sheet
140mm Mineral Wool
Predicted acoustic performance Predicted acoustic performance
23kg/m3 roll insulation Twin-Skin Roof and perforated liner sheet Frequency Hz 125 250 500 1000 2000 4000
vapour control layer, fully Frequency Hz 125 250 500 1000 2000 4000 Sound Reduction
sealed at all joints. Tegral Zeta Index (SRI) values dB 25 33 38 40 38 56
Sound Absorption
cladding rail
40mm Mineral Wool Coefficient 0.14 0.22 0.36 0.72 0.80 0.82
23kg/m3 roll insulation
Sound Reduction
Tegral 180mm spacer system 0.4mm Tegral 33/1000 Index (SRI) values dB 12.4 19.8 24.9 28.9 38.8 43.6
rail & bracket steel liner perforated
Zeta Purlin Weighted SRI Rw = 29.1 dB
59 60
DESIGNER’S ROOFING AND CLADDING GUIDE Environmental Sustainability DESIGNER’S ROOFING AND CLADDING GUIDE Environmental Sustainability
Sustainable Roofing & Cladding Systems Sustainable Roofing & Cladding Systems
European Union buildings should reduce 3. Photochemical Oxidant Formation: The world’s first CarbonNeutral Building Envelope In addition to this regulatory approach, a number of
energy waste by 22% Under certain climatic conditions, air emissions from companies are looking at voluntary initiatives to go
Insulation will be a key instrument to fulfil the EU industry and transportation can be trapped at ground The impact of global warming beyond compliance on climate change. Companies such
Energy Performance of Buildings Directive that was level where they react with sunlight to produce The impact of human activity could be significant at an as the CarbonNeutral Company have been set up to
passed in 2002. The EU expects the Directive to save photochemical smogs. economic, social and environmental level. The Stern help businesses achieve this voluntary action and
220 million tonnes of CO2 per year, of which 150 Report (2006) predicts if nothing is done about global reduce to net zero their unavoidable emissions. This
These are often seen in busy cities during the summer
million tonnes can be saved in a profitable or cost warming then the world economy could shrink by as involves assessing green house gas emissions, putting
and can be harmful. One of the components of smog
neutral way. much as 20% as global output reduces. To maintain in place actions to reduce these wherever possible and
is ozone, which is not emitted directly but is produced
manageable levels, emissions would need to stabilise off-setting the remaining through high quality
There are five main environmental impacts of through the interactions of volatile organic compounds
in the next 20 years and fall between 1% and 3% renewable energy and energy efficiency projects.
human activity (VOCs) and oxides of Nitrogen (NOx). Ozone is a
after that. This would cost 1% of GDP.
valuable substance in the earth’s stratosphere. Confidex Sustain™
1. The Greenhouse Effect:
However, ozone in the lower atmosphere is harmful Developing countries which are least likely to be able Tegral Metal Forming are proud to
This is the term used to explain the natural
and should not be confused with the ozone layer. to cope with climate change are most likely to be introduce Confidex Sustain? from
phenomenon that increases the temperature of the
affected. Their access to drinking water, for example, their pre-finsihed steel supply
earth’s surface. The incoming solar radiation is 4. Acidifaction:
would be further reduced, affecting the health of the partners, Corus. Confidex Sustain?
absorbed by the earth and reflected back towards the This is the process whereby acidifying gases released
poorest and posing a real threat to food security. offers the first Carbon Neutral building envelope in the
atmosphere at longer wavelengths. Certain gases into the atmosphere change the pH of terrestrial
Rising sea levels could leave 200 million people world, measuring and offsetting its impact from cradle
within the atmosphere (carbon dioxide, water vapour, watercourses and soils. The most significant
permanently displaced. to grave i.e. manufacture through to installation, use
methane and chloroflurocarbons) exhibit properties compounds in this process are sulphur and nitrogen
and end of life. As part of Corus continued
that in turn absorb this reflected radiation and elevate compounds. Acidifying compounds in a gaseous state Consensus from the 2005 Conference of Scientific
commitment to going beyond mere compliance on
the temperature of the lower atmosphere. may either be dissolved in water or fixed in solid Experts was that a temperature increase of 2o C above
environmental issues, action is being taken to reduce
The concentration of these greenhouse gases is particles. They reach ecosystems through dissolution the pre-industrial levels may trigger melting of the
to net zero the unavoidable CO2 emissions produced by
believed to influence the effectiveness of the in rain or by wet deposition. The effects of Greenland ice cap. Were this to happen the sea level
Colorcoat HPS200® and Colorcoat Prisma® pre-finished
phenomenon and hence the steady-state of acidification can be seen in the lakes of Scandinavia would rise dramatically changing the world map
steel products and the cladding systems they become
temperature of the earth. It is believed that man’s and North America, in coniferous forest decline, in soil substantially.
part of. Corus has been working over a number of
increased emissions of greenhouse gases is and in the erosion of building materials.
How is this being addressed? years to make Colorcoat HPS200® and Colorcoat Prisma®
contributing to the greenhouse effect. The resulting
5. Eutrophication: The UN Framework Convention on Climate Change was the most sustainable pre-finished steel products on
general increase in temperature could alter
Eutrophication is a form of water pollution. It is developed in 1992 and committed countries to take the market.
atmospheric and oceanic currents which could in turn
defined either in the enrichment in mineral salts of action to prevent the enormous climate change. Importantly Confidex Sustain™ will offset the impact
lead to potentially significant changes in weather
marine or lake waters when it refers to the natural Following 5 years of negotiation, the Kyoto Protocol from the entire building envelope system rather than
patterns. A rise in sea levels is also predicted due to
process or in the enrichment of nutritive elements of was agreed which made reductions mandatory among just one element such as the prefinished steel.
thermal expansion of the oceans and melting of the
waters when referring to human intervention. the developed economies. Although a number of
polar ice sheets. What is Confidex Sustain™?
Eurtrophication is primarily a natural process. significant countries have signed up to the Kyoto
Confidex Sustain™ offers the first Carbon Neutral
2. Resource Depletion: However, human activities have dramatically Protocol, including those in the EU including the UK,
building envelope in the world, measuring and
Abiotic resource depletion can be defined as the accelerated eutrophication by releasing phosphorus many large CO2 emitters such as the USA remain
offsetting its impact from cradle to grave i.e.
decreasing availability of natural, non-living, non- compounds (fertilisers, detergents etc.) outside the framework.
manufacture through to installation, use and end of life.
renewable resources. nitrogen compounds (fertilisers) and
The Kyoto Protocol commits countries rather than This means for every 1kg of CO2 emitted by the pre-
organic matter (urban and industrial
individuals or companies to achieve emissions finished steel, cladding, fixings and insulation, Corus
effluents) into watercourses.
reductions. The European Union has established an will off-set 1kg in climate friendly projects overseas.
Emissions Trading Scheme (EU-ETS) as a way to meet These have a social as well as environmental benefit
its Kyoto commitments. This scheme imposes caps on and will see Corus investing in projects such as
the level of emissions for certain sectors such as replacing kerosene lamps with solar panels for
power generation and cement and steel manufacture, communities in India.
and uses a trading platform so that regulated parties
and others can trade carbon to ensure that the
reduction targets are met.
61 62
DESIGNER’S ROOFING AND CLADDING GUIDE Environmental Sustainability DESIGNER’S ROOFING AND CLADDING GUIDE Environmental Sustainability
Sustainable Roofing & Cladding Systems Sustainable Roofing & Cladding Systems
Building on the success of the Corus Confidex® Key features of Confidex Sustain™ Supporting Confidex Sustain™ Our Partners
Guarantee, the first and most reliable construction
product guarantee, Confidex Sustain™ offers a zero
• Offsets the unavoidable CO2 emissions associated
with the pre-finished steel, cladding system, Environmental Product Declaration CarbonNeutral® Company
carbon building envelope system. It goes beyond insulation and fixings. Working with the leading climate change company The
An Environmental Product Declaration (EPD) provides a
considering just one element of the cladding system CarbonNeutral Company, Confidex Sustain™ provides a
to assess and off-set all parts including the inner and
outer pre-finished steel cladding sheets, fixings and
• Includes emissions from pre-finished steel cladding
system during manufacture,
summary of the environmental impacts of a product or
system from cradle to crave. The data published for
robust and fully auditable process to neutralise
unavoidable emissions. The CarbonNeutral Company
each of the Colorcoat® assessed cladding systems is
insulation. Confidex Sustain™ is available when a have over 10 years experience and work with over
based on an initial Life Cycle Assessment (LCA) study
Colorcoat HPS200® or Colorcoat Prisma® pre-finished installation, use and disposal/recycling. 200 clients including BSkyB, Honda, Avis Europe,
conducted by Corus in 2002 in accordance with the
steel product is used as part of a Colorcoat® assessed Barclays Bank, The World Conservation Union, Berkeley
cladding system. • Backed by a robust, reliable and fully traceable
process for investing in climate friendly projects,
international standard ISO 14040-3.
• Offered by Corus who has an excellent track record Once the building has been completed, the building
owner/occupier will receive a Confidex Sustain™
• The EPD summarises the environmental credentials
of a cladding system. This information can be used
for developing well researched, robust and credible
certificate with details of how much carbon has been in conjunction with whole life cost data, aesthetic
products and services, which deliver peace of mind
off-set and the types of project Corus is investing in. considerations, appropriate maintenance regimes
and real benefit for the supply chain.
and other building specific factors such as speed of
construction to determine the optimum cladding
solution for a particular building.
63 64
DESIGNER’S ROOFING AND CLADDING GUIDE Environmental Sustainability DESIGNER’S ROOFING AND CLADDING GUIDE Environmental Sustainability
Other benefits of using Tegral Built-Up Systems tightness of building details. These facilities were
used to test air leakage rates for different joint
Summary of end of life options
Refurbishment
• Fragmentation/shredding would release the blowing
agents from factory insulated foam filled composite
As a material, steel can deliver more adaptability to
configurations and provide best practice in terms of Refurbishment offers a well proven method for panels, so is not an option for those which contain, or
buildings than those made using other materials and
detailing for the building envelope. Air infiltration extending the life of the pre-finished steel building may contain, CFCs or HCFCs. While this is technically a
its strength can provide large open floor areas, giving
accounts for approximately 30% envelope either through overpainting, feasible route for small amounts of panels blown with
flexibility of use throughout a building’s life. The pre-
overcladding or recladding. HFCs or pentane, the high global warming potential of
finished steel cladding can last over 40 years, and be of the energy loss in a building and identifying ways
these gases mean that this process would cause
over-painted at intervals to prolong the life of the to optimise the air-tightness of the building envelope Re-use
significant environmental damage and so cannot be
building envelope further. can play a major role in conserving energy during a Built-up systems which are easy to disassemble are
recommended. If legislation in the UK and EU changes
building’s life. more frequently re-used, mainly in agricultural
Steel provides an engineered solution with tight to ban the release of such gases, as is anticipated, then
applications. There is very little re-use of factory
tolerances, pre-engineered in factory controlled Refurbish, Re-Use, Recycle this route would in any event no longer be available.
insulated composite panels (foam filled or mineral
conditions. For construction, this offers speed and When it comes to the end of a building’s life, the
predictability on site, reducing waste, minimising
disruption for local communities and enabling a
steel used in its construction can effectively be
refurbished, reused or recycled. There is a well
wool) mainly because of specific fixing requirements
and the need for careful removal of panels which can • Fridge recycling is likely to offer the most practical
option for disposal and recycling of factory insulated
take extra time. Reduced timescales for building
quicker handover to the client. Corus continuously established and very efficient steel recycling foam filled composite panels when blowing agents
demolition and the impact of Work at Height
looks for ways to improve the performance of our infrastructure which ensures all the scrap collected at need to be collected (as is currently the case for
Regulations 2005, mean that re-use rates are
products both functionally and environmentally, and end of life across all applications, goes back into steel CFC/HCFC and in the future likely for HFC/Pentane)
likely to reduce further.
as part of this we evaluate how our products are used manufacture. Steel is 100% recyclable and the use of However, panels would need to be cut down to fit the
during their lifetime. steel scrap will not compromise the quality of the Recycling/disposal current dimensions of the machines and this route is
new steel produced. Over 80% of all steel used in Built-up systems relatively costly.
Life cycle assessment
any construction project is reused or recycled at the A well established process is in place for handling built-
To demonstrate the environmental impacts of a steel
product during the manufacture, construction and
end of the building’s life. Of this a significant
proportion is pre-finished steel from roof and wall
up systems at end of life which is easy and cost effective.
• Incineration could be used to process the foam core
with the steel inner and outer sheet falling through as
operational phases of a building, Corus has carried out
a comprehensive life cycle assessment study,
cladding and tests have demonstrated that Corus
Colorcoat® pre-finished steel products can be recycled
• The pre-finished steel can be separated and
is 100% recyclable.
slag, mixed in with other materials. This reduces the
scrap value of the steel as it will be contaminated with
comparing Colorcoat® pre-finished steel products to
as steel scrap without any additional burden in terms other materials and has similar constraints to fridge
assess their environmental impact against a wide
range of environmental indicators. These found that
of emissions to the atmosphere. •Glass-fibre and mineral wool insulation can be
processed for re-use at lower grade and mineral
recycling in terms of panel size. This route is also the
most expensive.
the durability of the products always affects the An excellent example of how the recycling of steel
wool could be recycled effectively through the
results because of the environmental impact of can help save energy comes from the Lackenby open
manufacturing process. At present the majority Panels need to be treated carefully during demolition to
maintenance. It also found that the environmental hearth steelmaking building at Teesside. Demolished
of mineral wool and glass-fibre insulation liberated at ensure no release of gases.
impact of the pre-finished steel coating in 2004, the building contained over 20,000 tonnes of
disposal goes to landfill. There is little industry experience in handling factory
structural steel and cladding, 100% of which was
during manufacture is minimal compared with the insulated foam filled composite panels at end of life
recovered as scrap. Recycling this steel saved enough
overall construction process and the building’s full Demolition contractors are happy to recover built-up However, there will be a significant increase in the amounts
energy to supply over 3700 homes with their energy
lifetime. systems and use the scrapvalue of the steel to coming through in the next 10 years. Demolition contractors
requirements for one year and provided new high
offset their costs. perceive factory insulated composite panels as more difficult
Airtightness quality steel products for applications such as
and expensive to deal with than built-up systems.
50% of UK energy consumption is used in the structural sections used in the construction of Factory insulated foam filled composite panels One difficulty for the demolition contractors is the inability
operational phase of buildings and there are Heathrow Terminal 5. Different recycling/disposal options need to be to distinguish between CFC/HCFC and hydrocarbon blown
opportunities to enhance the thermal performance of
considered because of the potential risk of ozone panels, prompting the question ‘how do we know which
a building and reduce energy costs, using pre-finished
depleting or global warming potential gases being is which?’. For this reason, it is essential that accurate
steel cladding systems. The Corus Colorcoat® Centre for
released if not handled appropriately. records are kept of products used in the construction
the Building Envelope based at Oxford Brookes
process. Current options for landfilling are disappearing as
University, has developed one of the world’s most
advanced testing facilities for assessing the air • Landfill is not an option for the disposal of factory
insulated foam filled composite panels containing CFC
environmental controls become stricter and
fragmentation/shredding is only an option for certain
and HCFC blowing agents and this may also extend to panels (dependent on blowing agents used) and in small
Pentane and HFCs in the future. Practically very few volumes. Incineration is very expensive and destroys much
landfill sites will now accept any factory insulated foam of the steel scrap value
filled composite panels.
65 66
DESIGNER’S ROOFING AND CLADDING GUIDE Environmental Sustainability DESIGNER’S ROOFING AND CLADDING GUIDE Environmental Sustainability
Fig.5. Best practice route for disposal and recycling of pre-finished steel-based cladding systems Reassurance of International Standards: Colorcoat® products manufactured in the UK are
Tegral Metal Forming have been manufacturing in certified to the independently verified international
Ireland for over 30 years and have recently been management system, ISO14001 and are 100%
Steel cladding system awarded the ISO 14001 International Standard for recyclable. The Colorcoat® manufacturing site in North
Environmental Management. Wales contains a number of sites of special scientific
interest within its boundaries, demonstrating an ability
Material The Colorcoat® brand is the recognised mark of quality
classification
to manage our operations and their environmental
and metal envelope expertise from our supply
Built-up Composite impact without compromising biodiversity. This site
partners Corus. With over 40 years experience, Corus
has also been a winner of the Business Commitment
actively develop Colorcoat® products and processes to
to the Environment prize on numerous occasions most
reduce their environmental impact to a level beyond
recently in 2004.
mere compliance. All Colorcoat® products are
Mineral wool PUR/PIR foam manufactured in factory controlled conditions,
providing clear advantages on-site in terms of speed
of construction and minimising social disruption.
Table 1: Summary of anticipated costs for recycling and/or disposal of pre-finished steel cladding systems
67 68
DESIGNER’S ROOFING AND CLADDING GUIDE Environmental Sustainability DESIGNER’S ROOFING AND CLADDING GUIDE Environmental Sustainability
Confidex Sustain™ Available when Colorcoat HPS200® and/or Colorcoat Cradle to grave analysis
Confidex Sustain™ offers the first Prisma® are specified as part of a Colorcoat® assessed The cradle to grave analysis covers all life cycle stages.
Carbon Neutral building envelope in cladding system, Confidex Sustain™ covers the whole
the world, measuring and offsetting cladding system, from the pre-finished steel used for End of life
its impact from cradle to grave i.e. the inner and outer sheets, to the cladding, fixings
Includes impacts from:
manufacture through to installation, and insulation.
• built-up system steel content 79% recycled, 15% re-used, 6% landfill. Production of system components
use and disposal/recycling.
• composite panel steel content 100% recycled, 0% re-used, 0% landfill.
Includes impacts from:
• all insulation to landfill (foam and mineral wool). Although they have
the potential to be recycled current practice for demolition, and • production of pre-finished steel
Life cycle assessment and spacer bars.
infrastructure limitations, results in most insulants being landfilled.
Environmental impact categories:
• 95% recovery of composite panel blowing agent by fridge recycling process. • production of insulation.
• production of fixings and plastic
components.
69 70
DESIGNER’S ROOFING AND CLADDING GUIDE Environmental Sustainability DESIGNER’S ROOFING AND CLADDING GUIDE Environmental Sustainability
Fineline 19 Wall Cladding System Assumptions Arcline 40 Wall Cladding System Assumptions
With a reputation for proven weather protection,
durability and fire performance, Tegral Fineline 19 is
• The functional unit is 1000m2 of pre-finished steel
cladding in the main body of the roof or wall
With a reputation for proven weather protection,
durability and fire performance, Tegral Arcline 40™ has
• The functional unit is 1000m2 of pre-finished steel
cladding in the main body of the roof or wall
the most versatile profile in the range, this sinusoidal excluding rooflights and edge details at eaves, a distinct half-round shape and complements the excluding rooflights and edge details at eaves,
profile has a scale and form that contrasts with other ridges and walls. growing trend for feature elevations and curved ridges and walls.
materials on all building types.
The distinct profile allows for the choice of horizontal
• The cladding system is covered in entirety and
includes fixings, insulation and the inner and outer
building forms. Ideal for large-scale projects, Arcline
40™ maintains a strong visual impact even when • The cladding system is covered in entirety and
includes fixings, insulation and the inner and outer
viewed from a distance.
and vertical designs and can be used in a choice of pre-finished steel cladding sheets and their pre-finished steel cladding sheets and their
economical applications. associated spacers. Sealant strips, mastics and tapes An Environmental Product Declaration (EPD) provides a associated spacers. Sealant strips, mastics and tapes
have been excluded due to their negligible impact summary of theenvironmental impacts of a product or have been excluded due to their negligible impact
An Environmental Product Declaration (EPD) provides a
on the whole system analysis. system from cradle to grave. on the whole system analysis.
summary of theenvironmental impacts of a product or
system from cradle to grave.
• The cladding system lifetime is defined as the
appropriate Confidex® Guarantee Period for the
The data published here is based on an initial Life
Cycle Assessment (LCA) study conducted by Corus in
• The cladding system lifetime is defined as the
appropriate Confidex® Guarantee Period for the
The data published here is based on an initial Life
pre-finished steel product e.g. Colorcoat HPS200® 2002 in accordance with the international standard ISO pre-finished steel product e.g. Colorcoat HPS200®
Cycle Assessment (LCA) study conducted by Corus in
or Colorcoat Prisma® specified. 14040-3. This LCA has been subsequently refined and or Colorcoat Prisma® specified.
2002 in accordance with the international standard ISO
14040-3. This LCA has been subsequently refined and
extended to include more products and systems.
• Thermal performance is specified in accordance
with the Irish Building Regulations Part L, Elemental
extended to include more products and systems.
It is important that all LCA studies are carried out
• Thermal performance is specified in accordance
with Part L Building Regulations 2006, nominal
Heat Loss Calculation Method, nominal U-value 0.27 using this standard and that a critical review is used to U-value 0.32 Wm-2K for wall and 0.25 Wm-2K for
It is important that all LCA studies are carried out
Wm-2K for walls and 0.20 Wm-2K for roof systems. ensure high levels of quality and consistency. This will roof systems, with an air permeability bettering
using this standard and that a critical review is used to
Detailing and installation are in accordance with the make the results more meaningful for all parties. 10m 3/hr/m2. Detailing and installation are in
ensure high levels of quality and consistency. This will
MCRMA, system manufacturers installation guide accordance with the MCRMA, system manufacturers
make the results more meaningful for all parties.
and Corus best practice. installation guide and Corus best practice.
71 72
DESIGNER’S ROOFING AND CLADDING GUIDE Environmental Sustainability DESIGNER’S ROOFING AND CLADDING GUIDE Environmental Sustainability
Broad Rib C40 Wall Cladding System Assumptions Shadowline 47 Wall Cladding System Assumptions
Broad Rib C40 is a trapezoidal profile with an efficient
1000 mm cover width and 40 mm deep ribs. Between
• The functional unit is 1000m2 of pre-finished steel
cladding in the main body of the roof or wall
With a reputation for proven weather protection,
durability and fire performance, Tegral Shadowline
• The functional unit is 1000m2 of pre-finished steel
cladding in the main body of the roof or wall
the ribs each pan is characterised by twin excluding rooflights and edge details at eaves, 47™ is a louvre-like profile with sharp lines, providing excluding rooflights and edge details at eaves,
stiffening ribs. ridges and walls. strong contrast to flat wall panelling, making this the ridges and walls.
An Environmental Product Declaration (EPD) provides a
summary of theenvironmental impacts of a product or
• The cladding system is covered in entirety and
includes fixings, insulation and the inner and outer
most popular cladding profile for horizontal application
in Ireland. • The cladding system is covered in entirety and
includes fixings, insulation and the inner and outer
system from cradle to grave. pre-finished steel cladding sheets and their An Environmental Product Declaration (EPD) provides a pre-finished steel cladding sheets and their
associated spacers. Sealant strips, mastics and tapes summary of theenvironmental impacts of a product or associated spacers. Sealant strips, mastics and tapes
The data published here is based on an initial Life
have been excluded due to their negligible impact system from cradle to grave. have been excluded due to their negligible impact
Cycle Assessment (LCA) study conducted by Corus in
on the whole system analysis. on the whole system analysis.
2002 in accordance with the international standard ISO The data published here is based on an initial Life
14040-3. This LCA has been subsequently refined and
extended to include more products and systems.
• The cladding system lifetime is defined as the
appropriate Confidex® Guarantee Period for the
Cycle Assessment (LCA) study conducted by Corus in
2002 in accordance with the international standard ISO
• The cladding system lifetime is defined as the
appropriate Confidex® Guarantee Period for the
pre-finished steel product e.g. Colorcoat HPS200® 14040-3. This LCA has been subsequently refined and pre-finished steel product e.g. Colorcoat HPS200®
It is important that all LCA studies are carried out
or Colorcoat Prisma® specified. extended to include more products and systems. or Colorcoat Prisma® specified.
using this standard and that a critical review is used to
ensure high levels of quality and consistency. This will
make the results more meaningful for all parties.
• Thermal performance is specified in accordance
with the Irish Building Regulations Part L, Elemental
It is important that all LCA studies are carried out
using this standard and that a critical review is used to
• Thermal performance is specified in accordance
with the Irish Building Regulations Part L, Elemental
Heat Loss Calculation Method, nominal U-value 0.27 ensure high levels of quality and consistency. This will Heat Loss Calculation Method, nominal U-value 0.27
Wm-2K for walls and 0.20 Wm-2K for roof systems. make the results more meaningful for all parties. Wm-2K for walls and 0.20 Wm-2K for roof systems.
Detailing and installation are in accordance with the Detailing and installation are in accordance with the
MCRMA, system manufacturers installation guide MCRMA, system manufacturers installation guide
and Corus best practice. and Corus best practice.
73 74
DESIGNER’S ROOFING AND CLADDING GUIDE Environmental Sustainability DESIGNER’S ROOFING AND CLADDING GUIDE Environmental Sustainability
Fineline 19 Roof Cladding System Assumptions Wide Rib R33 Roof Cladding System Assumptions
Used as a roofing profile, Fineline 19 offers a
traditional effect that can contrast well with other
• The functional unit is 1000m2 of pre-finished steel
cladding in the main body of the roof or wall
A trapezoidal profile offering an efficient 1000 mm
coverwidth and providing a functional linear rib design
• The functional unit is 1000m2 of pre-finished steel
cladding in the main body of the roof or wall
contemporary cladding materials. excluding rooflights and edge details at eaves, with rib depths of 33 mm. excluding rooflights and edge details at eaves,
ridges and walls. ridges and walls.
An Environmental Product Declaration (EPD) provides a An Environmental Product Declaration (EPD) provides a
summary of theenvironmental impacts of a product or
system from cradle to grave.
• The cladding system is covered in entirety and
includes fixings, insulation and the inner and outer
summary of theenvironmental impacts of a product or
system from cradle to grave.
• The cladding system is covered in entirety and
includes fixings, insulation and the inner and outer
pre-finished steel cladding sheets and their pre-finished steel cladding sheets and their
The data published here is based on an initial Life The data published here is based on an initial Life
associated spacers. Sealant strips, mastics and tapes associated spacers. Sealant strips, mastics and tapes
Cycle Assessment (LCA) study conducted by Corus in Cycle Assessment (LCA) study conducted by Corus in
have been excluded due to their negligible impact have been excluded due to their negligible impact
2002 in accordance with the international standard ISO 2002 in accordance with the international standard ISO
on the whole system analysis. on the whole system analysis.
14040-3. This LCA has been subsequently refined and 14040-3. This LCA has been subsequently refined and
extended to include more products and systems.
• The cladding system lifetime is defined as the
appropriate Confidex® Guarantee Period for the
extended to include more products and systems.
• The cladding system lifetime is defined as the
appropriate Confidex® Guarantee Period for the
It is important that all LCA studies are carried out It is important that all LCA studies are carried out
pre-finished steel product e.g. Colorcoat HPS200® pre-finished steel product e.g. Colorcoat HPS200®
using this standard and that a critical review is used to using this standard and that a critical review is used to
or Colorcoat Prisma® specified. or Colorcoat Prisma® specified.
ensure high levels of quality and consistency. This will ensure high levels of quality and consistency. This will
make the results more meaningful for all parties.
• Thermal performance is specified in accordance
with the Irish Building Regulations Part L, Elemental
make the results more meaningful for all parties.
• Thermal performance is specified in accordance
with Part L Building Regulations 2006, nominal
Heat Loss Calculation Method, nominal U-value 0.27 U-value 0.32 Wm-2K for wall and 0.25 Wm-2K for
Wm-2K for walls and 0.20 Wm-2K for roof systems. roof systems, with an air permeability bettering
Detailing and installation are in accordance with the 10m 3/hr/m2. Detailing and installation are in
MCRMA, system manufacturers installation guide accordance with the MCRMA, system manufacturers
and Corus best practice. installation guide and Corus best practice.
75 76
DESIGNER’S ROOFING AND CLADDING GUIDE Weather Proofing
Tegral ALU-SEAM
77 78
DESIGNER’S ROOFING AND CLADDING GUIDE Weather Proofing DESIGNER’S ROOFING AND CLADDING GUIDE Weather Proofing
Roof Pitches & Lap Sealing Roof Pitches & Lap Sealing
Minimum recommended roof pitch Sealing method Composite Panels End Lap
Profile type Minimum pitch Inside joint sealing is suitable for
Application End lap Sealant
Secret fix 1.5º • side laps of liner panels with fully
supported (A section underlap)
length Requirement
End La
p 25mm
Trapezoidal (minimum 32mm height) 4º
• overlapping end laps of profiled
liner sheets.
150mm
Roofs 4º - 15º 150mm 2 lines of sealant
p
End La
Liner sheet sealing 150mm
75mm 15mm
The metal lining layer should be regarded as a 75mm
vapour control layer and also must be airtight.
15mm Metal
It is therefore absolutely essential to ensure
effective sealing, not only at liner sheet joints, but
also at all junctions especially at penetrations and Metal
roof to wall interfaces.
6 x 5mm or 6mm
Centre Bead
Butyl Strip Sealant
Support System
TM
Tegral Trisomet Tegral Arcline 40
79 80
DESIGNER’S ROOFING AND CLADDING GUIDE Fasteners DESIGNER’S ROOFING AND CLADDING GUIDE Fasteners
81 82
DESIGNER’S ROOFING AND CLADDING GUIDE Structural Performance DESIGNER’S ROOFING AND CLADDING GUIDE Structural Performance
The most commonly used structural type for Long span structural decking or structural liner trays can The structural performance of profiled sheeting may Failure modes
buildings using metal roof and wall systems is a hot be used to span directly between the main frames, be determined either by testing or by calculation. In determining the collapse load, the following
rolled steel structural frame. The cladding systems which dispenses with the need for secondary supports Normally, it is determined by calculation, except for failure modes are considered:
are supported from secondary steelwork consisting altogether. some profiles, such as concealed fix or raised
of purlins and rails made from light gauge cold Tensile Fracture
Timber framing is used for institutional, educational and seam profiles, which are outside the scope
rolled zinc coated steel (Tegral Zeta purlins and In practice, tensile failure is extremely unlikely since
domestic buildings and in some cases these will utilise of the design rules.
rails). Alternatively in older buildings the purlins and with thin plate elements the compressive instability
metal cladding systems. Reinforced or pre-stressed
rails may be timber, hot rolled steel sections or even Structural design is carried out in accordance with of the thin flanges is more critical.
concrete is sometimes used for portal frames.
pre-stressed concrete. BS 5950 : Part 6 : 1995 Structural use of steelwork
Compressive Buckling
in building. Part 6 : Code of practice for design of
Compressive buckling, rather than tensile failure,
STRUCTURE TYPE MATERIAL BRITISH STANDARD light gauge profiled steel sheeting.
is much more likely to be a limit on performance.
Further requirements on structural design are to be
Main Frame Hot rolled steel frame BS 5950-1: 2000 Structural use of steelwork in In calculation, the actual width of the compressive
found in BS 5427 : Part 1 : 1996 The use
building. Code of practice for design. Rolled and elements is reduced to account for the loss
of profiled sheet for roof and wall
welded sections. of strength caused by localised buckling.
cladding on buildings. Part 1. Design.
Compressive buckling is particularly relevant
Timber BS 5268-2:2002 Structural use of timber. Code of Limit state to wide compressive flanges, which are usually
practice for permissible stress design, materials In line with current practice, BS 5950 : Part 6 is stiffened by longitudinal ribs.
and workmanship. BS EN 408:1995 Timber based on 'Limit State' design principles. The load
structures. Structural timber and glued laminated
Shear Failure
bearing capacity of profiled sheeting is determined
timber. Determination of some physical and Shear failure is unlikely except in the webs of very
by two limiting loads: the ultimate limit load, i.e.
mechanical properties. deep profiles when they are used over short spans.
actual failure load, and the serviceability limit load,
For this reason, very deep profiles often contain
i.e. deflection limit load. (In the past design codes
Reinforced concrete BS 8110-1:1997 Structural use of concrete. Code web stiffener elements.
for profiled sheeting were traditionally based on
of practice for design and construction.
elastic design principles in which the upper limit on Web Buckling
Secondary supports (purlins for the Cold formed steel BS 5950-5:1998 Structural use of steelwork in loading is determined by limiting the maximum Web buckling can be a limiting factor in profiled
roof and rails for the walls) building. Code of practice for design of cold stresses in the profile to the yield stress divided by a sheeting, particularly when the sheets are used in
formed thin gauge sections. safety factor.) double span or multi-span conditions. In these
circumstances, failure would occur over intermediate
Load tables
Hot rolled steel BS 5950-1:2000 Structural use of steelwork in purlins, as a result of an interaction between
If the principles of limit state design were followed
building. Code of practice for design. Rolled and compressive buckling of the flanges and buckling of
welded sections.
exactly, load tables would show the collapse
the webs.
(ultimate limit) load for the profile. However this
Timber BS 5268-7.7:1990 Structural use of timber. would obviously be an unsafe practice and indeed Calculations required by BS 5950 : Part 6
Recommendations for the calculation basis for BS 5427 requires that published load/span tables Taking into account the above failure modes
span tables. Purlins supporting sheeting or decking. should be expressed as safe working loads. BS 5950 : Part 6 requires the following calculations:
Therefore, in Tegral’s published load tables, the
Single spans: Mid-span bending moment under
Reinforced concrete CP 115:1969 The structural use of prestressed limiting collapse load is divided by 1.5. Serviceability
upward and downward loading, web
concrete in buildings. (deflection) defined loads are not divided by a
crushing and shear at the supports.
factor. The load shown in the table is the least of
Structural Decking and structural Profiled steel BS 5950-6:1995 Structural use of steelwork in Double and Mid-span bending moment under
the lowest collapse load divided by 1.5 and the
liner trays building. Code of practice for design of light gauge
deflection-limited load. multi spans: upward and downward loading,
profiled steel sheeting.
combined bending and web crushing
BS 5950-9:1994 Structural use of steelwork in
at inner supports.
building. Code of practice for stressed skin design.
Combined bending and shear at
inner supports.
83 84
DESIGNER’S ROOFING AND CLADDING GUIDE Structural Performance DESIGNER’S ROOFING AND CLADDING GUIDE Structural Performance
Deflection limits Deflection limits are normally specified by the ratio Wind LoadkN/m2 Snow loadkN/m2 Uniformly distributed Concentrated load kN
A high deflection does not necessarily constitute a of the maximum deflection divided by the span. imposed load kN/m2
structural failure of the profiled sheet. In many cases The following span ratios are shown in
Roof with access As determined by As determined by 1.5 kN/m2 1.8 kN
it would be possible to exceed greatly the permitted BS 5950 : Part 6. BS 6399 Part 2 BS 6399 Part 3
deflection of a sheet, and still achieve 100% L:120 Wall Cladding under dead and wind load.
Roof with no access As determined by As determined by 0.6 kN/m2 0.9 kN
recovery on removal of the loading. L:200 Roof Cladding under dead and imposed load. BS 6399 Part 2 BS 6399 Part 3
L:500 Roof Cladding under dead load.
Deflection limits are usually chosen to prevent
The loads are not considered to act at the same time
consequential problems such as L:250 Is not shown in BS 5950 : Part 6 but is the
normal ratio used for structural roof decking under
• inadequate drainage at low pitches, due to
dead and imposed load. Imposed loads There are two methods given in the BS, a standard
ponding Two types of imposed load are considered, uniformly method and a directional method. The latter is a more
Limiting criteria distributed load (UDL) and concentrated load. accurate method determining the load from wind in
• broken seals at joints, causing leaking
In practice the limiting load on a profile may be any
These are defined by BS 6399 : Part 3 which
each direction, which allows for some refinement in
• undue strain at fixings on overlaps of the above, but longer spans tend to be deflection differentiates between roofs with access and roofs
design.
limited. This is especially noticeable on single span
• damage to or excessive strain between other
sheeting which deflects far more than sheeting in
without access, as may be seen in the above table.
Using the standard method:
connecting components or lining materials Concentrated load is assumed to act over a square with
double or multi span. The basic wind speed Vb is selected as above and the
sides of 125mm, BS 5950: Part 6 considers that
• surface distortions on flat panels. The designer of
concentrated load is equivalent to the line loading
loading is derived by the following procedure.
the building should choose the deflection limit,
as follows:
based on the combination of the profile and the 1. The site wind = Vb x altitude factor x directional
design and nature of the building. Apart from Concentrated Load Line Load speed Vs factor x seasonal factor x
specialised architectural cladding, the probability factor.
0.9kN 1.5kN/m2
considerations for walling are not as critical as 2. Select the “Terrain & Building Factor” Sb, from
Project: St. Vincent’s Centre, Dublin 1.8kN 3.0kN/m2
for roofing. This factor is reflected in the Architects: Burke-Kennedy Doyle Table 4; this depends on the distance to the sea,
relevant standards. Product: Tegral Seam-Loc the building height and town or country location.
Imposed load normally has a factor of 1.6 applied to it,
3. Effective wind speed Ve = Vs x Sb
dead load has a factor of 1.4.
4. Dynamic pressure qs = 0.613 x Ve2
Construction Loads
Where it is likely that construction loads will occur on 5. Select “External These depend on whether it is a
roof sheeting designed for the minimum imposed roof Pressure wall or roof, the building shape
loads for roofs with no access, BS 5950 Part 6 Coefficients” and the location of nearby
recommends that the line load of 1.5 kN/m should be 31
Cpe , from buildings. Each building face is
increased to 2 kN/m. sections 2.4 separated into zones with higher
30
26 buildings is calculated in
suction/pressure
25
24
Inverness
accordance with BS 6399:
Aberdeen
Part 2 Code of Practice
23
Oban
Perth
Dundee
for Wind Loads. 7. Select “Internal This depends on the building size
Glasgow
Edinburgh
25
Pressure and especially the openings.
The basic wind speed Vb is
26
25
Coefficients” Cpi ,
Belfast Newcastle
chosen according to
Sligo Carlisle
from section 2.6.
Westport
Dundalk
24 York
Sherburn geographical location
8. Internal wind pressure = qs x Cpi kN/m2
Preston
as shown on
23 Kingston-upon-Hull
23 Leeds
Galway Dublin Liverpool Manchester
Athlone
Sheffield
Limerick
Wexford
Stoke Nottingham
Norwich the map.
Cork
Waterford
Aberystwyth
Birmingham
Leicester
Northampton
25
Quick Estimates
24
Basic Wind Speed for UK & Ireland
Various quick estimating methods exist which are
Bedford 24
20 Ipswich
Swansea
25 Cardiff Oxford Map taken from
Bristol
21
London
22
23
BS 6399: Part 2: 1997 Basic wind reasonably accurate for simple buildings. The MCRMA /
speed in m/s - maximum gust speed
24
Plymouth
Bournemouth Brighton
85 86
DESIGNER’S ROOFING AND CLADDING GUIDE Structural Performance DESIGNER’S ROOFING AND CLADDING GUIDE Load Span
Snow Load The snow load on the roof is determined by the The Load/Span tables for each Tegral product may The following table indicates conservative load/span
The snow loading acting on buildings is calculated in following procedure: be found in the relevant product technical limits for the range of Tegral roofing and cladding
accordance with BS6399 : Part 3 Code of Practice for data sheet. profiles.
Imposed Roof Loads. 1. The site snow load so is calculated by simple
formula depending on altitude. LINER SHEETS
The basic snow load sb is chosen according to For altitudes of 100m or less s0 = sb
TEGRAL PRODUCT MATERIAL GAUGE (mm) WEIGHT (Kg/m2) LOAD/SPAN LOAD/SPAN
geographical location as shown on the map below. Maximum Span Maximum Span
2. The “snow shape coefficient”µi is derived. Load Span (mm) Multi Span (mm)
For roofs with pitch less than 30º µi = 0.8.
Mini Rib S 0.7 5.73 800 900
3. The snow load on the roof sd = µi x S0 kN/m2 Fineline 19 S 0.4 3.88 1200 1500
S 0.7 6.79 1200 1500
4. Local drifting can cause much higher load than
this and must be calculated for on roofs where it CL5-1000 S 0.4 3.75 1500 2000
might occur. Examples of these are roofs with S 0.7 6.57 1500 2000
valleys, roofs abutting walls or close to taller
CL5-1000 S 0.7 6.57 1200 1700
structures, roofs with parapets, roofs with tee Perforated (20%)
intersections, roofs with local projections greater
PL19 S 0.7 6.22 1400 1600
than 1m2. Simple procedures are given in
BS6399 : Part 3 to calculate the drift loading. S 0.4 3.88 1800 2000
0.6
0.5 Wide Rib 33-1000 S 0.7 6.75 1800 2000
0.8
The basic snow load normally will have a load factor
of 1.6 and snowdrift load will have a load factor of A 0.9 3.03 1500 1800
0.6 1.05 applied to it. Wide Rib 33-1000 S 0.7 6.75 1500 1800
Inverness 0.8
Perforated (20%)
1.0
A 0.9 3.03 1200 1500
Aberdeen
0.4
HL600/130 S 1.00 13.08 6000 6000
Oban
Dundee Liner Tray
0.5
Perth HL600/130
Glasgow
Edinburgh
Liner Tray S 0.75 9.81 5000 5000
0.2 0.8
0.8 Map taken from BS6399: Part 3: Perforated (30%)
1988 Basic snow load on the
0.5 0.4 2
ground, Sb in kN/m . Ground level is Note; S = Steel. A = Aluminium.
0.5 Carlisle Newcastle
0.2 Belfast assumed to be 100m above mean
Sligo
0.4
0.8 sea level.
Dundalk 0.6 ROOF PROFILES
Westport Sherburn
0.3
0.3 0.4 York
0.4
Preston
Leeds
Kingston-upon-Hull
TEGRAL PRODUCT MATERIAL GAUGE (mm) WEIGHT (Kg/m2) LOAD/SPAN LOAD/SPAN
Galway Athlone
Dublin Liverpool 0.6
0.5 Maximum Span Maximum Span
Manchester
Limerick 0.3 0.3 Sheffield Load Span (mm) Multi Span (mm)
0.5
0.4 Nottingham
Wexford
0.5 Stoke
Leicester
Fineline 19 S 0.7 6.81 1200 1500
0.3 Norwich
0.4 Birmingham
Cork
Waterford Aberystwyth
Northampton
0.5 A 0.9 3.05 900 1200
0.6
0.4
0.3 0.4 Bedford
Ipswich
R32 S 0.7 7.01 1800 2000
Swansea
0.4
Cardiff Oxford
London
A 0.9 3.01 1400 1800
Bristol
0.4
0.5 Wide Rib 33 S 0.7 6.75 1900 2000
0.3 Bournemouth Brighton
A 0.9 3.02 1500 1800
0.3 0.4
Plymouth
Broad Rib 40 S 0.7 6.75 2000 2000
A 0.9 3.02 1600 1800
Mid Rib 46 S 0.7 7.5 2700 3200
A 0.9 3.36 2100 2600
Deep Rib 60 S 0.7 8.44 3300 3800
A 0.9 3.78 2600 3200
Seam Loc S 0.7 7.99 1300 1800
®
Alu-Seam A 0.9 3.75 1500 2000
Note: S = Steel. A = Aluminium.
Note: assumes load of 1.20kN/m2 and deflection limit of L/200
87 88
DESIGNER’S ROOFING AND CLADDING GUIDE Load Span DESIGNER’S ROOFING AND CLADDING GUIDE None Fragile Roof Assemblies
CLADDING PROFILES When people walk on roofs during construction or The following table indicates the general requirements
maintenance there is always a risk. In accordance with in the case of Tegral Twin-Skin and Tegral composite
TEGRAL PRODUCT MATERIAL GAUGE (mm) WEIGHT (Kg/m2) LOAD/SPAN LOAD/SPAN Health and Safety guidance, and specifically, the HSA Draft panel roof assemblies –
Maximum Span Maximum Span Code of Practice for Safety in Roofwork, all new roof
Single Span (mm) Multi Span (mm) Note, the non-fragility performance of any metal
assemblies should be designed to achieve non-fragility
WP 40 S 0.7 7.50 2000 2200 roofing assembly is subject to the influence of
classification, and avoid the risk of injury or death caused
weathering, ultraviolet exposure, environmental
A 0.9 3.36 1700 2000 by falls through roof coverings. The appropriate method of
pollution and internal and external building
test in this regard is ACR[M] 001:2000 Test for Fragility of
Mini Rib S 0.7 5.73 800 900 environment. Tegral Metal Forming Ltd. therefore
Roofing Assemblies”.
Fineline 19 S 0.5 4.86 1200 1400 cannot indicate a specific period of time for non-
Where buildings are unlikely to have regular ongoing
fragility performance of any roof assembly containing
S 0.7 6.79 1300 1600 maintenance needs and access to the roof can be strictly
it’s products.
A 0.9 3.05 1100 1400 controlled, the roof assembly should be designed to a
minimum non-fragile standard – Class C to “Test for Recommendations and guidance for safe access to
PL19 S 0.7 6.22 1400 1600 Fragility of Roofing Assemblies” ACR[M]001:2000. roofs and working at heights may be obtained from the
Wide Rib C33 S 0.5 4.82 1800 1800 Health and Safety Authority.
It is important to note that the assembly (the
S 0.7 6.75 1800 2250 combination of roofing product, fasteners and method
A 0.9 3.02 1700 2100 of fixing, sealant and purlin spacing) is subjected to the
Broad Rib C40 S 0.5 4.82 1800 1400 non-fragility test and hence this assembly must be
replicated on site to ensure compliance.
S 0.7 6.75 1800 1800
A 0.9 3.02 1700 1700 MINIMUM NON-
PRODUCT MAXIMUM FIXING SPECIFICATION NUMBER OF FIXINGS SPAN END FRAGILE
Mid Rib C46 S 0.5 5.35 2800 2200 SPAN (mm) TYPE DISTANCE2 CLASS
S 0.7 7.5 3100 3600 (mm)
as single C
0.7mm roof shown 5.5mm Ø self drill screws 5 per sheet at sheet ends, 3 per
sheeting in the with 15mm washers sheet at intermediate supports 30
Load/
span double &
section multi B
Trisomet 5.5mm Ø self drill screws 5 per sheet at sheet ends, 3 per double & 30
Composite “ with 15mm washers sheet at intermediate supports multi B
Panel
1. The number of fixings per sheet must be increased proportionally when the sheet is cut at rake i.e. at hips.
2. Min. end distance is the minimum dimension between the centreline of the screws to the end of the sheet
3. Every other pitch is based on always starting with a fixing in the first pitch of every sheet.
89 90
DESIGNER’S ROOFING AND CLADDING GUIDE Structural Performance DESIGNER’S ROOFING AND CLADDING GUIDE None Fragile Roof Assemblies
In-plane GRP (Glass-fibre Reinforced Polyester) and polycarbonate rooflights Natural daylight is a vital element that will Full guidance on how best to incorporate natural
significantly improve the environment within any daylighting into building design may be obtained
Roof Application GRP Polycarbonate building. Rooflights provide three times more light in the MCRMA Technical Paper 1 - “Recommended
Minimum Non-fragile Minimum Non Fragile than the same area of vertical glazing. Good Practice for Daylighting in Metal Clad
Recommended Classification Recommended Classification Buildings”.
GRP Sheet Weight (when new) Polycarbonate (When New)
Sheet Weight
Single Skin
Single skin rooflight
Rigid trapezoidal
profiles 3.0kg/m2 Class B 1.2kg/m2 (1mm)* Class B
91 92
DESIGNER’S ROOFING AND CLADDING GUIDE Thermal Performance
93 94
DESIGNER’S ROOFING AND CLADDING GUIDE Thermal Performance DESIGNER’S ROOFING AND CLADDING GUIDE Thermal Performance
Maximum average U-value (Um) in relation Summary of elemental U-values (Elemental For Tegral roofing and cladding systems, the
Humidity Building Min.
to building volume (V) and total area of Heat Loss Method) calculation procedure as set out in Appendix D of
Class Type f value
heat loss elements (At) Draft TGD Part L Section 2 is followed.
0.16
0.20
0.22
Unheated Details should be assessed in accordance with the 1 Storage Areas 0.30
1.5 attic
methods described in I.S. EN ISO 10211-1:1996 and 2 Offices, Retail outlets 0.50
Average
U value
0.27
I.S. EN 10211-2:2001. This assessment should 3 Dwellings with low occupancy 0.65
2.201
establish the temperature factor 4 Sports Halls kitchens, canteens, 0.80
0.25
(fRsi) and linear thermal transmittance (ψ). buildings heated with un-flued
1.0 0.25
Unheated space The temperature factor (fRsi) is defined as follows: gas heaters. Dwellings with
0.27
Um (W/m2K)
fRsi = (Tsi - Te) / (Ti - Te) where: high occupancy
Tsi = minimum internal surface temperature, 5 Swimming pools, laundries, 0.90
0.25
NOTES Te = external temperature, and breweries
0.5
1. Windows, doors and rooflights should have maximum U-value Ti = internal temperature.
Um =0.24 + 0.19 V/At of 2.2 W/m2K and maximum opening area as set out below.
0.39 W/m2K
(subject to lower limit requirement
However areas and U-values may be varied provided the total The linear thermal temperature (ψ) is the calculated
of Um = 0.39 W/m2K
heat loss through these elements is not increased. correction factor for heat loss per unit length of a Additional heat loss (sum of ψ)
0
2. The U-value includes the effect of unheated voids or other spaces. linear thermal bridge.
0.8 1 2 3 4
Elemental Heat Loss Method:
Areas of Windows, Doors and Rooflights In order to facilitate compliance with this requirement
V/At (m) The additional heat loss associated with
(Elemental Heat Loss Method only) Tegral Metal Forming can provide specification
thermal bridges should be limited to less
As part of using the elemental method, these areas details which:
Elemental Heat Loss Method than 16% of the total calculated heat
To demonstrate acceptable transmission heat loss by
must be limited. The combined area of window,
door and rooflight openings should not exceed the
• are designed to reduce thermal bridging
(i.e. have a low ψ value)
loss through the plane building elements
this method, maximum average U-values for
individual building elements should not exceed
values given in the table below when the average
U-value is 2.2 W/m2K. However, this area may be
• are designed to reduce the risk of internal
condensation (i.e. have a high f value)
Overall Heat Loss Method:
those set out in the table below. varied provided the total heat loss through these Where the Overall Heat Loss method is
elements is not increased. • have been thermally modelled to produce
known values of ψ and f, which are then
used to show compliance, any additional
Maximum average elemental U-Value (W/m2K) heat loss above this level (16%) should
(Elemental Heat Loss Method) Maximum area of openings for average U-value of used in the whole building calculation.
be explicitly taken into account in
2.2 (W/m2K) (Elemental Heat Loss Method): calculating the Overall Heat Loss and the
Fabric Elements New Buildings & Material Alteration to
Permissible values for f & ψ
Extensions to or Material Changes Building Type Windows and doors Rooflights as associated average U-value.
Existing Buildings of Use of Existing as % of the area of % of area The temperature factor (fRsi)
Air infiltration
Buildings exposed wall of roof For dwellings, Technical Guidance Document Part L
Infiltration of cold outside air should be limited by
Pitched roof, Industrial gives a minimum value fRsi of 0.75, however there is
insulation 0.16 0.35 & storage 15% 20%
reducing unintentional air paths as far as is
no specific guidance given for other buildings.
horizontal at buildings practicable. A reasonably continuous air barrier
Designers have to ensure however, that any thermal
ceiling level Places of
should be provided over the whole thermal envelope,
bridge should not pose a risk of surface or interstitial
Pitched roof, assembly 40% 20% including elements separating the building from
offices & shops condensation. Although not mandatory, the following
insulation on 0.20 0.35 adjoining heated or unheated areas.
slope
guidance may be helpful to this end:
Residential 30% 20%
Buildings (Reference) Guidance for the
Flat roof 0.22 0.35
Design of Metal Roofing and Cladding to Comply with All Tegral roofing and cladding products and
Walls 0.27 0.60
Extensions L2 : 2001 - MCRMA Technical Guidance Paper No 14. systems are designed to minimise air leakage, and
Ground floors 0.25
Draft TGD Part L Section 2 also contains detailed enable air sealing criteria to be met, provided they
Other exposed are constructed correctly and that all other junctions
guidance as to how this table is applied to extensions.
Floors 0.25 0.60
and openings in the building are sealed properly.
External Thermal Bridging Regardless of the cladding material or system
personnel doors, To avoid excessive heat losses and local
windows and 2.201 2.20 chosen, it is essential that contractors take
condensation problems, provision should be made considerable care over air sealing.
rooflights
to limit local thermal bridging, e.g. around windows,
Vehicle access
and similar large 1.5 doors and other wall openings, at junctions between
doors elements and at other locations. Any thermal
bridge should not pose a risk of surface or interstitial
NOTE 1: Permitted average U-value of of external personnel
doors.windows and rooflights in building other than dwellings may
condensation and any excessive increase in heat loss
vary as described in Paragraph 2.1.3.2 of TGD. associated with the thermal bridge should
be taken account of in the calculation of
average U-value.
Figures in bold are the most relevant to Tegral roofing and cladding.
95 96
DESIGNER’S ROOFING AND CLADDING GUIDE Thermal Performance DESIGNER’S ROOFING AND CLADDING GUIDE Thermal Performance
Exposed Element U-value Tegral Twin-Skin System Tegral Composite Tegral Trinsul Method a) Composite panel roof
W/m2K Panel System A vapour control layer is essential, which in normal
environments may consist of sealed side and end laps
Profile metal external
All liners up to 33mm. Refer to Technical Refer to Technical of the metal liner sheet with continuity of the seal at sheet
For Insulation λ =0.04W/mk Services Services penetrations and junctions. Alternatively, a separate
Roof with integral 0.20 'Bracket & Rail' system Insulation
vapour control membrane may be laid over the metal
insulation 220mm deep. liner sheets with minimum 100 mm width sealed laps.
Insulation 200mm thick
The liner or vapour control layer should discharge any Metal Liner sheet
condensate externally.
97 98
® ®
DESIGNER’S ROOFING AND CLADDING GUIDE Corus Colorcoat Products & Services DESIGNER’S ROOFING AND CLADDING GUIDE Corus Colorcoat Products & Services
® ®
Corus Colorcoat Products and Services Corus Colorcoat Products and Services
® ®
To ensure the long-term performance and Colorcoat Prisma® Repertoire colour consultancy Colorcoat Connection helpline
® ®
appearance of the building, it is important that the The ideal choice to deliver eye-catching buildings The Repertoire colour consultancy can advise on For more information about Corus Colorcoat
pre-finished steel product is specified alongside that will stand the test of time. Technically and colours and colour strategies using a range of products and services visit
the cladding system. aesthetically superior to PVDF (PVF2), Colorcoat standard shades, as well as discussing individual www.colorcoat-online.com or
®
®
Prisma® is readily available in the most popular solid bespoke colour requirements. call the Colorcoat Connection helpline
The Colorcoat brand provides the recognised mark
and metallic colours. on +353 (0)1 631 0615.
of quality and metal envelope expertise exclusively Corus can match almost any shade from physical
from Corus. Over the course of 40 years, Corus has All backed up with the unique Confidex® Guarantee swatches to commonly used references such as RAL,
®
developed a range of technically leading Colorcoat providing cover for up to 25 years on walls. NCS and British Standard and more unusual
pre-finished steel products which have been standards.
Colorcoat Celestia ®
comprehensively tested and are manufactured to ®
and guidance. Colorcoat Armacor® Available with Colorcoat HPS200 , Colorcoat Celestia
® ®
Colorcoat Armacor® is a high-build pre-finished steel and Colorcoat Prisma , the Confidex Guarantee is
Colorcoat HPS200®
product with a tough and attractive textured clear and simple to register, can easily be
Exclusive coating technology, superior performance
® top-coat. transferred if building ownership changes and
and the unique Confidex Guarantee make Colorcoat
provides peace of mind and reduced risk for the
HPS200® the most specified pre-finished steel As a medium term building envelope solution,
supply chain.
product in Europe for roof and wall cladding. Now Colorcoat Armacor® offers a price competitive
maintenance free for up to 30 years. durable alternative to leathergrain plastisols.
Topcoat
Primer
Pre-treatment
Metallic coating
Substrate
Metallic coating
Pre-treatment
Primer
Backing coat
99 100
DESIGNER’S ROOFING AND CLADDING GUIDE Aesthetics DESIGNER’S ROOFING AND CLADDING GUIDE General practice
The combination of a Colorcoat® product, exclusively Corus HPS200® Metal roof and wall cladding should be fully detailed Mitred Corners
developed and manufactured by Corus, and a cladding A pre-finished steel for roof and wall cladding. on cladding drawings for each individual building. Mitred corners or curved corners can be
system from Tegral Metal Forming, offers the highest
®
Colorcoat HPS200 uses an exclusive coating The drawings should include all the necessary manufactured by Tegral Metal Forming in the profile
dimensions, components, fasteners, seals etc. to used for the horizontal wall cladding.
quality and performance for a building envelope. formulation and Galvalloy® substrate to offer
enable the sheeters to install the cladding in These replace conventional corner flashings, and
superior durability and colour retention all backed accordance with the designer’s requirements, in allow the continuation of the wall cladding profile
Selection ®
® up by the Confidex guarantee, covering cut edges order to achieve the specified performance. around the corner. Careful alignment on both
Typically the choice of Colorcoat product is based on
for up to 30 years. It has a 200 micron top coat and Responsible supervision and regular inspection is planes is always required.
aesthetic design or planning requirements. ®
essential to ensure structural integrity, satisfactory
unique Scintilla emboss on the weatherside and a Liner Sheets
Alternatively, the selection may be dictated by site performance, acceptable appearance and
high performance polyester backing coat as standard It is possible to fix the complete twin skin system
conditions. A wide range of Colorcoat® products are quality in general.
on the reverse side. Its Galvalloy substrate is to progressively, or line out the building completely
available to suit practically every design or budget The steel framework should be surveyed prior to before the installation of outer sheets.
® EN10124 with a 95%/5% zinc/aluminium metallic
consideration. As a general rule, there are Colorcoat handover to the roofing/cladding contractor. Any
coating offering superior corrosion resistance and In both instances, attention is required to ensure a
products available through Tegral to suit most applications. deviations in line, level and plumb must be
enhanced cut edge protection. non-fragile assembly as outlined on page 64.
acknowledged by all parties and the necessary
Materials adjustments made to suit the cladding requirements It is recommended that the metal liner sheet be
The standard range consists of 29 colours including
The choice of material depends on specific before starting the installation. utilised both as a vapour control layer and to
two metallic effect finishes, with the further option
environmental conditions (internal and external) provide the air sealing required by Draft Technical
®
of Repertoire colour matching service. Transport, handling and storage
that pertain. Tegral roofing and cladding products Guidance Document L. All laps and junctions in the
Loading and off-loading packs by crane or fork-lift
are manufactured from:- More detail available on- lining layer must be effectively sealed - See page 75
should be carried out with care to avoid damage to
for sealing recommendations.
www.colorcoat-online.com the outermost sheets or panels in the pack.
Substrate Gauge Never off-load with chains, use only wide soft slings Laying outer sheets
Double-sided Colorcoat HPS200® is also for lifting. Use lifting beams, if recommended. Where possible, the outer sheets should be laid with
Galvanised steel to BS EN10147:1992 0.4mm available on request. the exposed joints of the side laps away from the
Packs should be carefully positioned and stored on
0.55mm prevailing wind unless shown otherwise on
Colorcoat® Lining Enamel site to prevent damage or deterioration. Particular
drawings. Should this not be possible the side laps
0.7mm Colorcoat ® Lining Enamel has been specially attention should be paid to the following points:
®
should always be sealed.
Galvalloy steel to BS EN 10214 1995 0.4mm developed by Corus for steel lining sheets and trays a) Position away from vehicle and pedestrian routes.
0.55mm Rail and Bracket Support Systems
to provide an efficient and durable internal lining b) Site on bearers on firm flat ground.
See relevant fixing information for the system
0.7mm system. It has good light reflecting properties and c) Cover and ventilate.
being used.
Stucco Embossed aluminium mill-finish d) Ensure labelling is intact.
a smooth easy-to-clean surface. The standard
to IS EN 508-2:2000 0.9mm Generally brackets are fitted at not more than 1
reverse side coating is a specially formulated Some sheets and panels are supplied with a
metre centres. Anti sway brackets may be required
Coated Aluminum to BS EN 1396:1996 0.9mm two coat protective system of corrosion resistant protective plastic film on the weatherface to help
on roofs, for some systems.
prevent minor damage to the coating. This must be
Colorcoat® Products primer topped with a heat cured high-
removed as soon as possible after the cladding has Insulation material
Whereas the choice of a particular Colorcoat® product performance polyester. been installed because if it is left in place for long Glass fibre or mineral wool roll or quilt insulation
for any given Tegral roof and wall cladding system Coated Aluminium periods the film will become very difficult to should be used and the thermal properties must
may be dictated by specific site conditions, typically remove. Manufacturer’s instructions should always match the design values used for the U-values
Aluminium’s tough, inert, chemically stable oxide
be followed. shown on pages 71.
the decision is based on aesthetic design layer inhibits corrosive attack and reforms
considerations or planning requirements. The choice spontaneously if the surface is damaged. Horizontal Wall Cladding Install the insulation as work proceeds ensuring all
The long horizontal lines created by horizontal wall edges are close butt jointed to achieve continuity
offered through Tegral allows for the selection of a The surface of rolled aluminium is ideally suited
cladding emphasise any imperfections in the between spacers. There must be no gaps. The
suitable Colorcoat product to suit design or to receiving a choice of organic coatings, cladding or support steelwork. Therefore a higher insulation can be installed in more than one layer, if
economic criteria. so producing a long decorative life, with low standard of steelwork alignment and sheet fixing is so the joints in each layer should be offset. The
® maintenance requirements. required than is the case for vertical cladding. insulation quilt must be cut and tucked under the
Colorcoat Products
spacer bar so that there is no air gap under the bar.
Whereas the choice of a particular Colorcoat® product ARS It is also recommended that the cladding contractor
It is important to keep the insulation dry.
for any given Tegral roof and wall cladding system allow for packing when fixing the outer sheet, to
A high durable coating with exceptionally good
ensure that any deviations from a true plane can be
may be dictated by specific site conditions, typically handling characteristics. compensated for. Even so it is still possible that
the decision is based on aesthetic design considerations there may be minute but visible deviation from a
or planning requirements. The choice offered flat line in the material.
through Tegral allows for the selection of a suitable
Colorcoat product to suit designor economic criteria.
101 102
DESIGNER’S ROOFING AND CLADDING GUIDE DESIGNER’S ROOFING AND CLADDING GUIDE General practice
103 104
DESIGNER’S ROOFING AND CLADDING GUIDE Support Services
All products from Tegral Metal Forming are supported by the following professional services:
Sales Team
Each member of our Sales Team provides guidance on
product selection and assists with competitive pricing
and accurate quotations.
Sales
Tel: 00 + 353 (0) 59 86 40740
Fax: 00 + 353 (0) 59 86 40741
Email: metalsales@tegral.com
Technical Services
Tegral Metal Forming provides a comprehensive
advisory service. Free to all customers, each member
of the Technical Team offers the benefits of their
experience over many years in the building industry.
Committed to providing the best guidance on the use
of the Tegral product range and applications, the
team is available to assist at any stage with your
project. Technical information is also available on the
website at www.tegral.com
Customer Service Technical Services
Once you have decided to purchase from Tegral Tel: 00 + 353 (0) 59 86 40750
Metal Forming, our dedicated Customer Service Team Fax: 00 + 353 (0) 59 86 40751
will guide you through the process. From the Email: metaltech@tegral.com
moment your order is placed, right through to
delivery at your selected location, a customer service
representative is available to assist you…from
beginning to end.
Customer Service
Tel: 00 + 353 (0) 59 86 40700
Fax: 00 + 353 (0)59 86 40701/11