VAD SERIES

ADJUSTABLE BLADES AXIAL FLOW FANS


ADJUSTABLE BLADES AXIAL FLOW FANS

on E PCD F

ØB
ØA
According to motor

Fan ØA ØB C ØD E F

Direct-drive Axial Flow Fan (VAD 250


Series) 315 315 385 8 10.5 355 250
400 400 480 8 10.5 440 250
• Designed for installation in a ducted
ventilation such as General ventilation of 450 450 530 8 10.5 490
commercial and industrial sites, 500 500 580 12 10.5 540 300
warehouse and storage ventilation, car
parks and public buildings. 560 560 640 12 10.5 600 300
• Available in sizes 315 up to 2000mm. 630 630 710 12 10.5 670 300
• The casings are manufactured from high
grade rolled and flanged sheet steel and 710 710 790 16 12.5 750 300
protected by polyester paint finish.
• The impellers are manufactured from 800 800 900 16 12.5 850 300
aluminium injection-moulded (from 315
up to 1250) and high grade die-cast 900 900 1000 16 12.5 950 400
aluminium (from 1400 up to 2000).
1000 1000 1100 16 12.5 1050 450
• The complete adjustment of blade pitch
angle provides precise selection of 1250 1250 1356 20 15 1306 450
pressure and airflow. 1400 1400 1506 20 15 1456 500
• All impeller are dynamically balanced to
ISO-1940 to ensure vibration-free
1600 1600 1740 24 17 1680 500
running.
• All series are using asynchronous
induction motors with a squirrel cage
rotor as standard. The motors with
specification: three Phase 380V / 50Hz,
class F Insulation and IP 55 protection
system.

2 The best solution in ventilation


ADJUSTABLE BLADES AXIAL FLOW FANS

◼ Dimensions [mm] of VAD and VAP Series ◼ Motor Power Ratings and Weight

Frame Motor Power Ratings Approx.


See Casing long-cased Size
C holes ØD
2P 4P 6P 8P Weight
on E PCD Length Table. short-cased

D56 0.09 0.06 - - 3.5

D63 0.18 0.12 0.09 - 4.8


ØB
ØA

D71 0.37 0.25 0.18 0.12 7.2

D80 0.75 0.55 0.37 0.18 10.8


D90S 1.5 1.1 0.75 0.37 13.4
According
Foot Mounting (optional)
to motor
D90L 2.2 1.5 1.1 0.55 17.5
D100L 3 2.2 1.5 0.75 27
VAD Series
D112M 4 4 2.2 1.5 32
Casing D132S 5.5 5.5 3 2.2 48
Fan Size ØA ØB C ØD E
Weight [kg]
250 D132M - 7.5 4 3 60
315 315 385 8 10.5 355 8,6
400 400 480 8 10.5 440 12,5 D160M 11 11 7.5 4 78
450 450 530 8 10.5 490
D160L 18.5 15 11 7.5 87
500 500 580 12 10.5 540 16,5
D180M 22 18.5 - - 100
560 560 640 12 10.5 600 18,5
D180L - 22 15 11 122
630 630 710 12 10.5 670 21
710 710 790 16 12.5 750 30,5 D200L 30 30 18.5 15 148
800 800 900 16 12.5 850 51,5
D225S - 37 - 18.5 207
900 900 1000 16 12.5 950 -
D225M 45 45 30 22 230
1000 1000 1100 16 12.5 1050 98
1250 1250 1356 20 15 1306 235 D250M 55 55 37 30 264
1400 1400 1506 20 15 1456 267 D280S 75 75 45 37 362
1600 1600 1740 24 17 1680 - D280M 90 90 55 45 427
1800 1800 1940 24 17 1880 - D315S 110 110 75 55 713
2000 2000 2160 24 17 2090 - D315M 132 132 90 75 953

◼ How to Order ◼ Casing Length Table


Motor Casing Length [mm]
VAD / 4 - 800 / 5 / 32 / B - 5.5 kW
Frame VAD
VAP
Size Short Long
Absorbed Power [kW]
Airflow Direction [A|B] D56 - D63 250 400
400
D71 - D80 450
Blade pitch angle [degree] 300
D90 450 500
Number of blades D100 - D112 400 500 550
D132 450 600 700
Fan Size [mm] D160 - D180 600 800
D200 700
Number of pole 1000
D225 - D250 800
D280 1200
Type of product : 1000
D315 1300

The best solution in ventilation 3


VADT/H SERIES
ADJUSTABLE BLADES AXIAL FLOW FANS
ADJUSTABLE BLADES AXIAL FLOW FANS

Galvanized Axial Flow Fan (VADT/


VADTH Series)
• Designed to extract high temperature air
or smoke.
• Available in sizes 315 up to 1600mm.
• The casings are manufactured from high
grade hot dipped galvanized steel and
the impellers are manufactured from high
grade aluminium injection-moulded. All
impellers are dynamically balanced to
ISO-1940 to ensure vibration-free
running.
• VADT series are using three Phase
asynchronous motors 380V/50Hz, class
F Insulation, IP 55 protection system.
• VADTH series are using three Phase
asynchronous motors 380V/50Hz, class
H Insulation, IP 55 protection system and
rated at 200°C/2h.( for explosion proof
motor and rated at 400°C/2h - please
enquire).

2 The best solution in ventilation


ADJUSTABLE BLADES AXIAL FLOW FANS

◼ Dimensions [mm] of VADT Series

Fan
ØA ØB C ØD E F
Size
315 315 385 8 10.5 355 250
400 400 480 8 10.5 440 250
500 500 580 12 10.5 540 300
560 560 640 12 10.5 600 300
630 630 710 12 10.5 670 300
300
710 710 790 16 12.5 750
400
300
800 800 900 16 12.5 850
400
900 900 1000 16 12.5 950 400
1000 1000 1100 16 12.5 1050 450
1250 1250 1356 20 15 1306 450
1400 1400 1506 20 15 1456 500
◼ How to Order
1600 1600 1740 24 17 1680 500
VADT / 4 - 800 / 5 / 32 / B - 5.5 kW

Absorbed Power [kW]


Airflow Direction [A|B]
Blade pitch angle [degree]

Number of blades

Fan Size [mm]

Number of pole

Type of product :

The best solution in ventilation 3


VAB SERIES
ADJUSTABLE BLADES AXIAL FLOW FANS
ADJUSTABLE BLADES AXIAL FLOW FANS

◼ Dimensions [mm]

VAB-400/500/630

Cas.Weig
Models ØA ØB C ØD ØF G ØK ØM N ØP
ht [kg]

VAB-400 400 480 500 500 580 8 10,5 440 12 540 32

VAB-500 500 580 630 630 710 12 10,5 550 16 670 36

VAB-630 630 710 710 710 790 12 10,5 670 16 750 56

◼ Description
• Designed to be installed within ducted
ventilation system such as commercial
dryer and kitchen cooker canopy
ventilation, or where the extract of
gasses.
• Available in sizes 400 up to 1400mm.
• The fan casing is formed from rolled
sheet steel with rolled duct connection
flanges.
• The motor is isolated from the air
stream in a tunnel between the split
fan casing.
• motor is cooled by an impeller
mounted on the non drive end of the
motor.

2 The best solution in ventilation


ADJUSTABLE BLADES AXIAL FLOW FANS

◼ Dimensions [mm]

VAB-800/1400
ØB
ØA

D x ØE C

Casing
Models ØA ØB C D ØE F ØG
Weight [kg]

VAB-800 800 900 900 16 12.5 850 - 97

VAB-1000 1000 1100 1100 16 12.5 1050 - 148

VAB-1250 1250 1356 1220 20 15 1306 - 179

VAB-1400 1400 1506 1535 20 15 1456 - -

◼ How to Order

VAB / 4 - 800 / 5 / 32 / B - 5.5 kW

Absorbed Power [kW]


Airflow Direction [A|B]
Blade pitch angle [degree]

Number of blades

Fan Size [mm]


Number of pole :[8|6|4|2]
Type of product :[VAB]

The best solution in ventilation 3


VAD SERIES
ADJUSTABLE BLADES AXIAL FLOW FANS
ADJUSTABLE BLADES AXIAL FLOW FANS

on E PCD F

ØB
ØA
According to motor

Fan ØA ØB C ØD E F

Direct-drive Axial Flow Fan (VAD 250


Series) 315 315 385 8 10.5 355 250
400 400 480 8 10.5 440 250
• Designed for installation in a ducted
ventilation such as General ventilation of 450 450 530 8 10.5 490
commercial and industrial sites, 500 500 580 12 10.5 540 300
warehouse and storage ventilation, car
parks and public buildings. 560 560 640 12 10.5 600 300
• Available in sizes 315 up to 2000mm. 630 630 710 12 10.5 670 300
• The casings are manufactured from high
grade rolled and flanged sheet steel and 710 710 790 16 12.5 750 300
protected by polyester paint finish.
• The impellers are manufactured from 800 800 900 16 12.5 850 300
aluminium injection-moulded (from 315
up to 1250) and high grade die-cast 900 900 1000 16 12.5 950 400
aluminium (from 1400 up to 2000).
1000 1000 1100 16 12.5 1050 450
• The complete adjustment of blade pitch
angle provides precise selection of 1250 1250 1356 20 15 1306 450
pressure and airflow. 1400 1400 1506 20 15 1456 500
• All impeller are dynamically balanced to
ISO-1940 to ensure vibration-free
1600 1600 1740 24 17 1680 500
running.
• All series are using asynchronous
induction motors with a squirrel cage
rotor as standard. The motors with
specification: three Phase 380V / 50Hz,
class F Insulation and IP 55 protection
system.

2 The best solution in ventilation


ADJUSTABLE BLADES AXIAL FLOW FANS

◼ Dimensions [mm] of VAD and VAP Series ◼ Motor Power Ratings and Weight

Frame Motor Power Ratings Approx.


See Casing long-cased Size
C holes ØD
2P 4P 6P 8P Weight
on E PCD Length Table. short-cased

D56 0.09 0.06 - - 3.5

D63 0.18 0.12 0.09 - 4.8


ØB
ØA

D71 0.37 0.25 0.18 0.12 7.2

D80 0.75 0.55 0.37 0.18 10.8


D90S 1.5 1.1 0.75 0.37 13.4
According
Foot Mounting (optional)
to motor
D90L 2.2 1.5 1.1 0.55 17.5
D100L 3 2.2 1.5 0.75 27
VAD Series
D112M 4 4 2.2 1.5 32
Casing D132S 5.5 5.5 3 2.2 48
Fan Size ØA ØB C ØD E
Weight [kg]
250 D132M - 7.5 4 3 60
315 315 385 8 10.5 355 8,6
400 400 480 8 10.5 440 12,5 D160M 11 11 7.5 4 78
450 450 530 8 10.5 490
D160L 18.5 15 11 7.5 87
500 500 580 12 10.5 540 16,5
D180M 22 18.5 - - 100
560 560 640 12 10.5 600 18,5
D180L - 22 15 11 122
630 630 710 12 10.5 670 21
710 710 790 16 12.5 750 30,5 D200L 30 30 18.5 15 148
800 800 900 16 12.5 850 51,5
D225S - 37 - 18.5 207
900 900 1000 16 12.5 950 -
D225M 45 45 30 22 230
1000 1000 1100 16 12.5 1050 98
1250 1250 1356 20 15 1306 235 D250M 55 55 37 30 264
1400 1400 1506 20 15 1456 267 D280S 75 75 45 37 362
1600 1600 1740 24 17 1680 - D280M 90 90 55 45 427
1800 1800 1940 24 17 1880 - D315S 110 110 75 55 713
2000 2000 2160 24 17 2090 - D315M 132 132 90 75 953

◼ How to Order ◼ Casing Length Table


Motor Casing Length [mm]
VAD / 4 - 800 / 5 / 32 / B - 5.5 kW
Frame VAD
VAP
Size Short Long
Absorbed Power [kW]
Airflow Direction [A|B] D56 - D63 250 400
400
D71 - D80 450
Blade pitch angle [degree] 300
D90 450 500
Number of blades D100 - D112 400 500 550
D132 450 600 700
Fan Size [mm] D160 - D180 600 800
D200 700
Number of pole 1000
D225 - D250 800
D280 1200
Type of product : 1000
D315 1300

The best solution in ventilation 3


DIRECT DRIVE CENTRIFUGAL FANS

VDFA SERIES
CENTRIFUGAL CABINET FANS
CENTRIFUGAL
CENTRIFUGAL CABINET
CABINET FANS FANS
VDFA Series

VDFA—315

VDFA—250

The VDFA Series range of Double inlets


belt drive cabinet fans offer of wide and
static pressure development performanc-
es.

The series are suitable for many general


ventilation applications where prcise
continuos volume flow rates are required. VDFA—200
Typical applications include:
• Commercial offices,
• Public building,
• Restaurant,
• Commercial and industrial kitchen.

The fan casing are manufactured from


heavy gauge galvanized sheet steel with
VDFA—180
double thickness side panels.All panels
are internally lined widh high density
acoustic insulation.

The impeller of VDFA series has forward


curved blades manufactured from high VDFA—160
quality galvanized sheet steel.All impeller
are statically and dynamically balanced
to USO 1940 standars to ensure vibra-
tion-free running.

VDFA—140

2 The best solution in ventilation


CENTRIFUGAL CABINET
CENTRIFUGAL CABINETFANS
FANS
VDFA Series

Tehnical Data

Max. RPM
Voltage dB
Model Max m3/h Power Phase Hz Curent
(V) (A)*
(A)
Low High
VDFA/4/6-140 600 75 1 50 0.6 220 50 900 1400
VDFA/4/6-160 1200 125 1 50 0.7 220 53 900 1400
VDFA/4/6-180 2700 150 1 50 1.1 220 57 900 1400
VDFA/4/6-200 3200 200 1 50 1.2 220 53 900 1400
VDFA/4/6-250 3500 250 1 50 6.0 220 54 900 1400
VDFA/4/6-315 6750 370 1 50 5.6 220 58 900 1400

Model A B C D E F G I J K
VDFA-140 350 300 350 165 105 55 250 30 30 360
VDFA-160 400 350 400 185 120 65 280 30 30 410
VDFA-180 430 380 430 210 138 65 315 30 30 440
VDFA-200 480 440 480 250 255 65 325 40 30 510
VDFA-250 600 530 600 300 315 95 450 40 30 600
VDFA-315 675 620 640 396 341 95 480 50 30 700

The best solution in ventilation 3


CENTRIFUGAL CABINET FANS
VDFA Series

■ Performance Curve
VDFA/4/6/160

VDFA/4/6/180 VDFA/4/6/200

VDFA/4/6/250 VDFA/4/6/315

4 The best solution in ventilation


THE BEST SOLUTION IN VENTILATION
Indonesia Office:

PT. Vanco Mas Sejahtera


Komplek Ruko Mega Grosir Cempaka Mas blok D1 No.31
Jl. Letjen R. Suprapto, Jakarta 10640, Indonesia
Phone : +62(21) - 4290 6789
Fax : +62(21) - 4290 6744
Email : info@vancofan.com / info@vanco.co.id
Website : www.vancofan.com
VGH/VGTH SERIES
FIXED BLADES AXIAL FLOW FANS
FIXED BLADES AXIAL FLOW FANS
Forceful Plate Mounted Exhaust Fan — VGH/VGTH Series VAG Series

◼ Application
The VGH/VGTH range are designed to be installed directly into walls,
ceilings or panels and are suitable for use within a wide range of
general ventilation applications such as industrial premises,
agricultural applications, warehouses, car parks, work shop,
refrigeration equipment, air conditioning units, etc

◼ Technical Parameters

Max. abs. Rating Rating Air Sound


Speed
Model Power Voltage Freq. Volume Level
[rpm]
[W] [V~] [Hz] [m³/h] [dB]
VGH/VGTH -300 1350 100 220/380 50 1800 59
VGH/VGTH -350 1350 150 220/380 50 2400 64
VGH/VGTH -400 1350 200 220/380 50 2880 69
VGH/VGTH -450 1350 250 220/380 50 4920 70
◼ Description VGH/VGTH-500 1350 270 220/380 50 6360 74
VGH/VGTH -600 1350 700 220/380 50 11760 83
The VGH/VGTH series range of
forceful plate mounted axial fans
consists of six nominal diameters: ◼ Dimensions [mm]
300, 350, 400, 450, 500 and
600mm respectively.
Air volume performance ranges
from 1800 up to 11760 m3/hr.
ØD

ØC

The motor and fan impeller are


firmly supported within the
mounting plate by a strong steel
support frame. B
All models incorporate a four A E F
blades impeller manufactured from
galvanized steel sheet and
finished with a epoxy paint. The Model A B ØC ØD E F
impellers are factory matched and VGH/VGTH -300 388 308 8.5 325 12 245
balanced onto the corresponding VGH/VGTH -350 435 333 8.5 365 14 260
motors. VGH/VGTH -400 482 368 8.5 412 15 260
The VGH series incorporate single VGH/VGTH -450 557 433 10.5 473 15 270
phase shaded pole asynchronous VGH/VGTH -500 600 470 10.5 507 17 290
induction motors, with electrical VGH/VGTH -600 697 585 12.5 618 20 310
supply 220V/50Hz.
The VGH series incorporate Three
phase asynchronous induction
motors, with electrical supply
380V/50Hz.

2 The best solution in ventilation


FIXED BLADES AXIAL FLOW FANS
VAG SeriesForceful Plate Mounted Exhaust Fan — VGH/VGTH Series

◼ Performance Curves

The best solution in ventilation 3


VIT SERIES
INLINECENTRIFUGAL DUCT FAN
INLINE CENTRIFUGAL DUCT FAN

◼ Construction
All VIT Series fans are manufactured from high grade corrosion
resistant pressed galvanized sheet steel. The range are specifically
designed for direct size circular ducting, 100 - 355mm diameter
respectively. All models are supplied as standard with a remotely
mounted wiring junction box to provide the installer with a
completely flexible choice for positioning and installation.
All models include an enclosed, single phase 220V/50Hz, external
rotor motor. All motor include sealed for life ball bearing
assemblies and class B, IP44 protection.
All VIT Series fans include a non-stalling backward curved impeller
which is factory matched to the corresponding external rotor motor
and dynamically balanced to ISO/1940 standards for vibration free
operation. The motor and impeller assembly are suitable for
operation at any angle and deliver exceptional airflow
performances against the high static pressure typically found in
ducted ventilation systems.
The VIT Series of in-line circular
duct fans consist of eight nominal ◼ Technical Parameters
model sizes 100, 125, 150, 160, Max. Sound
Fan Max. Max.
200, 250, 315 and 355 mm
Speed Abs. Abs. Air Press. Weight
respectively. All models are Model Power Current Volume Level
designed for direct connection in-
[W] [A]
line with standard diameter circular [rpm] [m3/h] [dB(A)] [kg]
ducting. Air volume performance
VIT-100 2460 75 0.33 330 50 3.5
ranges from 290 up to 1,900 m3/h.
VIT-125 2350 75 0.35 390 50 3.5
All VIT Series model incorporate a
VIT-150 2420 100 0.53 740 53 6.2
powerful single phase, 220V 50Hz
VIT-160 2640 133 0.55 880 53 6.2
external rotor motor that has been
VIT-200 2600 140 0.72 1150 55 7.2
factory matched to a non-stalling
backward curved centrifugal VIT-250 2390 157 0.80 1380 56 7.2
impeller. VIT-315 2378 199 1.45 1600 57 7.9
VIT-355 2500 650 4.00 2400 60 11
The VIT Series of fans are ideally
suited for a wide range of ◼ Performance Curves
residential, commercial and
industrial exhaust or supply
ventilation applications. Typical
applications would include the
following:
Residential
Bathrooms, toilets, utility rooms.
Commercial
Cafes, bars, offices, restaurants.
Industrial
Spot ventilation, equipment
cooling, workshop ventilation.

2 The best solution in ventilation


INLINE CENTRIFUGAL DUCT FAN

◼ Installation and Operation ◼ Dimensions [mm]


1. The inlet and outlet directly connect with the duct, fastened by
the plastic clamp, firmly fixed by suspender.
2. The insulation resistance test should be needed if the fans kept
at the warehouse for more than half a year before operation.
The resistance should be over 20MΩ.
3. Rotate the impeller by hand before operation and check its
flexibility to make sure without bump or block. Connecting with
power source, having impeller and motor working to observe
• Direction of rotation should correspond to direction-of-rotation
arrow on the label.
• Smoothness of motor operation (no overheat, abnormal
noise, impeller gradually slow)
If not, it approves to operate in normal condition.
4. For durable purpose, the inhaler and single-way valve are Model A B C ØD ØE
suggested to fix on the air inlet. VIT-100 195 145 25 98 243
VIT-125 195 145 25 123 243
◼ Maintenance and Repair
VIT-150 215 165 25 148 333
We recommend inspection of the impeller every six moths if the fan
VIT-160 222 172 25 158 333
is operated continuously. Internal insulation or dust may be wiped
clean with a dry cloth. Strong detergents or cleaning liquid must not VIT-200 222 172 25 198 333
be used for cleaning the fan. If in the condition of heavy dust, it’s VIT-250 205 155 25 248 333
suggested to clean up at times to prevent duct affecting it VIT-315 230 180 25 312 402
operation. VIT-355 400 350 25 352 492
Easy to disassemble. The motor and impeller could be cleaned up Any changes of specification without further notice.
by removing plastic clamp, suspender, connecting box and then
unscrewing the four pieces bolts on the housing.

The best solution in ventilation 3