Babcock & Wilcox

Renewables

Company Presentation

© 2021 The Babcock & Wilcox Company. All rights reserved. THE BABCOCK & WILCOX COMPANY 1
B&W Renewables A/S (Denmark)

Head quartered in
Esbjerg, Denmark
Business areas Plant Locations

Waste -to-Energy +800 plants EU, USA,


India, China, Korea,
Biomass-to-Energy +50 plants Malaysia, Indonesia

Service & Parts Employees

Operation & Maintenance 275


Approximately

History 2000 Acquired by B&W

1898 1931 1980 2021


Founded First waste-to-energy plant First biomass-fired plant Fully integrated in B&W
© 2021 The Babcock & Wilcox Company. All rights reserved. THE BABCOCK & WILCOX COMPANY 2
Proven Technology
Always improving
Chute-to-stack • State-of-the-art
technology
and ongoing R&D • technology development

Increasing steam
parameters in waste • Gross electrical efficiency of >30%
plants
PROVEN
Increasing • 8000 hrs guaranteed, up to 8,400 demonstrated TECHNOLOGY
availability • 18 months between major stops

Fuel flexibility • DynaGrate® pivoting combustion grate


– a key consideration • Key funding requirement

© 2021 The Babcock & Wilcox Company. All rights reserved. THE BABCOCK & WILCOX COMPANY 3
Core Technologies
Four ways to ensure cleaner state-of-the-art energy production

Reliable, high State-of-the-art In-house Advanced


quality combustion furnaces and technologies combustion control
grates boilers • Flue gas cleaning • VoluMix™
• DynaGrate® • Inconel® corrosion • Sootblowers • High effective SNCR
• Vølund grate protection
• Vibrating grates • Water-cooled wear
zone

© 2021 The Babcock & Wilcox Company. All rights reserved. THE BABCOCK & WILCOX COMPANY 4
DynaGrate®
The grate is based on unique design
High availability & long operation
No contact between the moving grate bars
Inter locked motion mechanism between bars
Transport is created by the force of gravity
Limits the wear-and-tear => Low maintenance cost
 Fuel flexible
 MSW, RDF, SRF & Waste Wood
 Intense turbulent combustion = high speed air in air gaps
 Excellent fuel agitation
 Good burnout = very low TOC %
 Not sensitive to metals

Modular design
 1 (3 - 20 t/h) or 2 (20 - 44 t/h) combustion lanes
 4 individual combustion sections in each lane
 Speed control
 Excess air control => Low NOx
 4-6 shafts in each section
 Air cooled (LHV < 12 MJ/kg) & Water cooled (LHV < 22 MJ/kg)
 Upgrade to water cooled at limited cost

For more on the DynaGrate® check B&W Volund on Youtube:


https://www.youtube.com/watch?v=blSfP0s0A64

© 2021 The Babcock & Wilcox Company. All rights reserved. THE BABCOCK & WILCOX COMPANY 5
Amager Bakke/ Copenhill, Denmark
Energy-from-Waste

Product Lines
• Features an
artificial ski slope
• High steam
data + CHP
• 440°C and 67 bar

• 2 lines
• 35 t/h per line
• Commissioning 2017

© 2021 The Babcock & Wilcox Company. All rights reserved. THE BABCOCK & WILCOX COMPANY 6
Filborna/Helsingborg, Sweden
Energy-from-Waste

Product Lines
• Boiler
• 425°C and 50 bar
• Very low Nox emissions
obtained using SNCR only

• 1 line
• 27 t/h
• Commissioning 2013

© 2021 The Babcock & Wilcox Company. All rights reserved. THE BABCOCK & WILCOX COMPANY 7
Dunbar/Scotland, UK
Energy-from-Waste

Product Lines
• Boiler lot
• High steam
data + CHP
• 440°C and 65 bar
• Flue gas cleaning lot

• 2 lines
• 22.8 t/h per line
• Commissioning 2019

© 2021 The Babcock & Wilcox Company. All rights reserved. THE BABCOCK & WILCOX COMPANY 8
West Palm Beach, USA
Energy-from-Waste

Product Lines
• First waste-to-energy plant
in USA in 17 years
• One of the largest in the
world (2,700 t/d)
• In co-operation with our
parent company

• 3 lines
• 37.8 t/h per line
• Scope: DynaGrate®
• Commissioning 2015

© 2021 The Babcock & Wilcox Company. All rights reserved. THE BABCOCK & WILCOX COMPANY 9
EfW at Sakra, Singapore
Energy-from-Waste

Product Lines
• Main contractor:
JV: Hyundai-HEC
• BWV delivery: 2 pcs.
DynaGrate®, wear zones,
design of boiler and
feeding equipment

• 403 °C / 54 bar
• 150 t/h steam
• 2 lines
• 24 t/h per line
• Commissioning 2016

© 2021 The Babcock & Wilcox Company. All rights reserved. THE BABCOCK & WILCOX COMPANY 10
Shenzhen East, China
Energy-from-Waste

Plant data
• Client: Shenzhen Energy
• Comm. year: 2019
• 6 x 936 t/day
• Steam data: 450°C, 65 bar(a)
• BWV scope: Design and
Equipment - 6 DynaGrates®,
feeding pusher, hydraulic
system, burners
• Construction and
commissioning advisory
assistance

For a video check: https://www.youtube.com/watch?v=ALhOIqZNkWk


© 2021 The Babcock & Wilcox Company. All rights reserved. THE BABCOCK & WILCOX COMPANY 11
B&W selected WtE references, I of (III)

© 2021 The Babcock & Wilcox Company. All rights reserved. THE BABCOCK & WILCOX COMPANY 12
B&W selected WtE references, II of (III)

© 2021 The Babcock & Wilcox Company. All rights reserved. THE BABCOCK & WILCOX COMPANY 13
B&W selected WtE references, III of (III)

© 2021 The Babcock & Wilcox Company. All rights reserved. THE BABCOCK & WILCOX COMPANY 14