Professional Documents
Culture Documents
Status Report Tralux 323e Rap01030 Low Voltage - PSRPT - 2021-07-23 - 08.19.56
Status Report Tralux 323e Rap01030 Low Voltage - PSRPT - 2021-07-23 - 08.19.56
Status Report Tralux 323e Rap01030 Low Voltage - PSRPT - 2021-07-23 - 08.19.56
0
Product Status Report
23-07-2021 08:19
Monitor System
Parameter Value
ECM Part Number 3095711-07
Software Group Part Number 4783420-00
Software Group Release Date FEB2015
Software Group Description E HEX MONITOR Application
Logged Diagnostic Codes [Diagnostic Clock = 8226 hours] - C6.6 320E (C8N25577)
Code Description Occ. First Last
247-14 SAE J1939 Data Link : Special Instruction 3 7879 8226
Logged Event Codes [Diagnostic Clock = 8226 hours] - C6.6 320E (C8N25577)
Code Description Occ. First Last
No Logged
Event Codes
Logged Diagnostic Codes [Diagnostic Clock = 8226 hours] - Machine Control 320E/F & 323E/F
(RAP01030)
Code Description Occ. First Last
3685- 9 Tilt Bucket Angle Sensor : Abnormal Update Rate 19 7732 8054
1952- 9 Chassis Angle Sensor : Abnormal Update Rate 2 7810 7810
1956- 3 Bucket Cylinder Position Sensor : Voltage Above 1 7440 7440
Normal
41- 6 8 Volt DC Supply : Current Above Normal 1 7440 7440
1657- 4 Left Joystick Thumbwheel : Voltage Below Normal 1 7440 7440
1658- 4 Right Joystick Thumbwheel : Voltage Below 1 7440 7440
Normal
Logged Event Codes [Diagnostic Clock = 8226 hours] - Machine Control 320E/F & 323E/F
(RAP01030)
Code Description Occ. First Last
No Logged
Event Codes