EMI Filter 6A AK Delta

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

V

SERIES POWER ENTRY MODULE EMI FILTERS D E

INTRODUCTIONS SPECIFICATIONS
1. Power module incorporates an IEC connector, a fuse holder with 1. Maximum leakage current each
optional power on/off switch and voltage selector switch, plus line-to-ground @ 115VAC 60Hz: 0.25mA
an EMI filter all-in-one single, easy-to-install unit. @ 250VAC 50Hz: 0.45mA
2. Fuse holder designed for one IEC 5x20mm fuse. Safety interlock 2. Hipot rating (one minute)
prevents fuse removal with line plug inserted (Use only with 250V line-to-ground: 2250VDC
fuse). line-to-line: 1450VDC
3. All part numbers are UL recognized, CSA certified and VDE 3. Operating frequency: 50/60Hz
approved. 4. Rated voltage: 115/250VAC
4. Switch electrical lifetime: 10,000 cycles.
Maximum inrush current: 70A.

MINIMUM INSERTION LOSS IN dB


COMMON MODE (L-G) IN 50 OHM SYSTEM
CURRENT FREQUENCY-MHz
RATING .15 .50 1.0 5.0 10 30
3A 30 35 40 35 35 35
6A 16 25 30 42 45 40
DIFFERENTIAL MODE (L-L) IN 50 OHM SYSTEM
3A 10 40 45 45 45 35
6A 6 25 30 42 45 40

TYPE & RATED CURRENT


DELTA PART NO. AK1 AK2 AK2D AK3 AK3D AK4 AK5
115VAC 6A 6A 6A 6A 6A 6A 6A
RATED CURRENT
250VAC 6A 6A 4A 6A 4A 6A 6A
IEC CONNECTOR
FUSE HOLDER
POWER SWITCH SP1 DP2 SP1 DP2
VOLTAGE SELECTOR SW REAR3 REAR3 REAR3 FRONT4
ELECTRICAL SCHEMATIC FIG. A FIG. A FIG. B FIG. A FIG. B FIG. A FIG. C
1. Single-pole UL, CSA & VDE approved 3. Voltage selector SW -UL, CSA & VDE approved
Current rating: UL & CSA-6A both at 125VAC & 250VAC; Current rating: 10A at 125VAC; 5A at 250VAC.
VDE-6A at 250VAC. 4. Voltage selector SW -UL, CSA & VDE approved

POWER ENTRY MODULE FILTERS


2. Double-pole UL CSA & VDE approved Current rating: UL & CSA-6A both at 125VAC & 250VAC;
Current rating: UL & CSA-6A at 125VAC, 4A at 250VAC; VDE-6A at 250VAC.
VDE-4A at 250VAC.

ELECTRICAL SCHEMATIC
AK1/4 WITHOUT POWER SW AK3/4 ONLY
F SW L' L' SW 1
L L
Cy L F Cy L 110V 110V
L L R C1 C2 O 2
C1 R C2 O I
I L A 220V
N
L A N
D E Cy D
E N'
Cy N
N' 110V 3
N G
G G' G' 220V 110V 4
FIG. C
FIG. A AK3D ONLY
For transformers with two separate windings
F SW L'
L
Cy
L L
C1 R C2 O
I
L A
N
E D
Cy N'
N
G G'
FIG. B

4-1
R0.04Max.
1.0

1.063 0.003
27.0
Suggested thickness of mounting
panel is from 0.04 to 0.07 inch
2.6 0.003
Suggested mounting cutout 66.0

MECHANICAL CONSTRUCTION
L
1 2
G G

1.15
29.2

1.059
26.9
220
110
N L
4 3
N

2.65
67.3

0.57
14.48
2.24
56.9
2.17
55.1

0.43
10.9
AK5 2.57
65.3

2.65
67.3

N
G O G

1.059
26.9
1.15
29.2

N L
I
L
2.38
60.5
2.17
55.1

AK2,AK2D 2.57
65.3

2.65
67.3

G O
1.15
29.2

N L I
POWER ENTRY MODULE FILTERS

2.60
66.0

G
AK3,AK3D
115V

0.65
16.5

AK4 (without power switch)


1.059
2.65 26.9
67.3

G
1.15
29.2

N L
2.24
56.9

2.17
55.1

AK1 INCH
2.57 1.059
26.9
UNIT: mm
65.3

4-2