Reference/Betreff : The heater of the cabin takes more corrent us expected.
: Alll Single - Drum - Rollers -3 Generation
:Single - Drum - Roller —3 Generation
During the last time we are receiving more and more complaints about the 10 Amps. fuse,
Pos. 5 at the cabin. The fuse melts during the use of the heater .
Our investigations show that the current of the heater fan is between 10 Amps. and 11 Amps.
Therefor the 10 Amps. fuse is not strong enough.
As a solution we switched over to a 15 Amps. fuse. The cables of the heater are sufficient for
the higher load.
Generally the fuse Pos. 5 should be changed during a technical visit or an inspection.
The P/N of the 15 Amps. fuse is 057 510 98.