BOMAG S I Central Service ERVICE ENFORMATION a re | NoJ/Nr. : 11/011/2001 Status : Repl.for /Ersatz fur 3 Date/Datum 05.01.01 File/Fach : Page/Seite 21 offvon 1 Author/Verfasser: J.Thome Reference/Betreff : The heater of the cabin takes more corrent us expected. : Alll Single - Drum - Rollers -3 Generation :Single - Drum - Roller —3 Generation During the last time we are receiving more and more complaints about the 10 Amps. fuse, Pos. 5 at the cabin. The fuse melts during the use of the heater . Our investigations show that the current of the heater fan is between 10 Amps. and 11 Amps. Therefor the 10 Amps. fuse is not strong enough. As a solution we switched over to a 15 Amps. fuse. The cables of the heater are sufficient for the higher load. Generally the fuse Pos. 5 should be changed during a technical visit or an inspection. The P/N of the 15 Amps. fuse is 057 510 98. TK/J.Thome SERVIIOIL