SATR-A-2009 Rev 2 - System Lay-Up Report (Certificate)
SATR-A-2009 Rev 2 - System Lay-Up Report (Certificate)
SATR-A-2009 Rev 2 - System Lay-Up Report (Certificate)
Note: This Cert is used for Lay-up Checklists SAIC-A-2018 (Plant Piping & Equipment) & SAIC-L-2124 (Pipelines)
Certificate No. Date:
Equipment: Service Fluid:
System Lay-up Duration: Start - End Date:
Hydro Test Medium: Type of Lay-up:
METHOD OF LAY-UP Actual Pass Fail Remarks
Wet Lay-Up
Minimum residual oxygen scavenger concetration in water
shall be 20 ppm & maximum O2 concentration of 10 ppb
Maintain the system under a positive pressure between 30 to
50 psig using nitrogen, sweet hydrocarbon gas or hydraulic
pressure of the treated water
Use gages to monitor the positive pressure in the system
during lay-up with a scale range not exceeding three times the
target pressure. (Gages must withstand MAOP)
Dry Lay-Up
Test water drained from the system until no visible water or
moisture is present.
If sea water was used for testing, remove salt deposits until
sulfates and chlorides on the steel surface reduced to less than
80 mg/msquare.
Page 1 of 2
SAUDI ARAMCO ID/PID - 18-MAY-05 - REV 0 (Standards Cutoff - December 2005) Rev 2 31-Dec-05
SATR NUMBER DATE APPROVED QR NUMBER
SAUDI ARAMCO TEST REPORT
System Lay-up Report (Certificate) SATR-A-2009 1-Dec-06 Mech-
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR
Note: This Cert is used for Lay-up Checklists SAIC-A-2018 (Plant Piping & Equipment) & SAIC-L-2124 (Pipelines)
Quality Record Approved: Name, Organization, T&I Witnessed QC Record Reviewed Work Verified
Name, Sign and Date:
Initials and Date:
*Person Responsible for Completion of Quality Work / Test Y = YES N = NO F = FAILED
Page 2 of 2