Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Model: DE220E5

Powered by DEUTZ

Generator Specification

Service PRP (1) ESP (2) Performance Data

Power (kVA) 200 220 Model DE220E5

Power (kW) 160 176 Engine brand Deutz


Engine model BF6M1013FCG3
Rated speed ( r.p.m) 1500
Speed control type ECU
Standard voltage (V) 400/230V
Phase 3
Rated at power factor(cos phi) 0.8
Control system Digital

AU VE
Star ter motor voltage 12/24V
RI
BURE

ISO 9001
TA S

BUREAU VERITAS
Certification
182 8
Frequency 50HZ
Engine speed (RPM) 1500
AGG Power gensets are compliant with ISO 9001 and CE standard, which include the
following directives: 100% standby power -
·2006/42/EC Machinery safety. Fuel
·2006/95/EC Low voltage 100% prime power 50.8
·EN 60204-1: 2006+A1: 2009, EN ISO 12100: 2010, EN ISO 13849-1: 2008, EN Consumption
75% prime power 37.7
12601 : 2010 (L/H)
50% prime power 25.3
(1) PRP (Prime Power):
According to ISO8528-1, prime power is the maximum power available during a variable
Standard reference Conditions
power sequence, which may be run for an unlimited number of hours per year, between
Note: Standard reference condition 25℃ (77℉) air inlet temp, 100m(328ft) A.S.L 30%
stated maintenance intervals. The permissible average power output during at 24 hours
relative humidity. Fuel consumption dat with diesel fuel with specific gravity of 0.85 and
period shall not exceed 80% of the prime power. 10% overload available for governing
conforming to BS 2869: 1998, Class A2
purposes only.

(2) ESP (Standby Power):


L L
According to ISO 8528-1, It is defined as the maximum power available, under the
agreed operating conditions, for which the generating set is capable of delivering for up
to 500 hours of operation per year (of which no more than 300 hours for continuative H
H
use) with the maintenance intervals and procedures being carried out as prescribed by
W W
the manufacturers. No overload capability is available.

Dimension and Weight


Dimension Open Silent
Powers ESP PRP Standby
Length (L) 2650mm 3950mm
Voltage (V) KVA KW KVA KW Amps
Width (W) 1140mm 1250mm
415/240 220 176 200 160 306.1
Height (H) 1680mm 2035mm
400/230 220 176 200 160 317.6 Net Weight 1800KG 2616KG
380/220 220 176 200 160 334.3 Fuel Tank (L) 350L 405L
Engine Specification: BF6M1013FCG3

Basic technical data Output

No. of cylinders 6 Gross output (LTP) 201 KW

Cylinder arrangement In-line Fan reduction 7.2 KW

Cycle 4 stroke Net flywheel 193.8 KW

Injection system Single injection pumps Electrical output 218kVA

Displacement 7.146 L Gross output (PRP) 183KW

Bore 108 mm Gross output (Continous power) 166KW

Stroke 130 mm
Compression ratio 18.1:1
Mean effective pressure 11.9 bar Lubrication system

Piston speed 6.5m/s Oil specification TR0199-99-3002/6

Rotation CCW Oil consumption

Engine dry, w/o cooling system 708kg (as % of fuel consumption) 0.3

Oil capacity (sump) 20 L

Min. oil pressure (warning) 2.7 bar

Min. oil pressure (shut down) 2 bar


Cooling system
Max. permissible oil temp(oil pan) 130°C
Delivery of coolant pump 10.9 m³/ h

Min. pressure before coolant pump 0.3 bar

Coolant capacity(engine) 9.8 L

Coolant capacity (incl. cooling unit) 27.3 L Electrical system

Air to boil 50℃ Voltage 12V

Fan power consumption 7.2 KW Star ter 3KW

Cooling air flow 11520 m³/ h Alternator output 55A

Air pressure loss, external 1.5 mbar

Heat balance

Heat dissipation (engine radiator) 96.1 KW

Heat dissipation (CAC) 42 KW

Heat dissipation (Convection) 20.0 KW

Inlet / Exhaust Data

Max. intake depression(switch setting) 25 mbar

Combustion air volume 745.6 m³/ h

Max. exhaust back pressure 30 mbar

Max. exhaust gas temperature 530 ℃

Exhaust gas flow (at above temp) 2122 m³/ h

Exhaust flange/pipe diameter TBD


Alternator Specification
Emergency voltage curve

Sudden increase warp


Alternator Sudden voltage warp Sudden decrease warp
520
Number of phase 3

Power factor (Cos Phi) 0.8 464

+ 1%
Poles 4 408 +380
1%
380
- 1%
Winding Connections (standard) Star-serie 352

Terminals 12 296

Insulation type H class 240


0 1 2 3 4 5 6 7 8 9 10 11 12
δu%: -18.18 Benchmark phase: A Min. voltage: 310.9V Recovery time: 1. 95s
Winding Pitch 2/3 δu%: 8.89 Benchmark phase: A Recovery time: 0..12ss
Max. voltage: 413.8V

IP rating IP23

Excitation system Self-excited

Bearing Single bearing Emergency frequency curve


Coating Vacuum impregnation Sudden increase warp
Sudden frequency warp Sudden decrease warp
70
Voltage regulator A.V.R

Couping Flexible disc 62

54 +1%%
+-1150
%
50
- 1%
46

38

30
0 1 2 3 4 5 6 7 8 9 10 11 12
δf%:
%: -10.64 Benchmark phase: A Min. frequency: 44.68Hz Recovery time: 1.
. 95s
Three phase Reliable Single phase
δf%:
%: 7.74 Benchmark phase: A Max. frequency: 53.87Hz Recovery time: 0..54s

Options

Engine Alternator Generator Sets Fuel System

· Water Jacket · Winding Temp measuring · Tools with the machine · Low fuel level alarm
Pre-heater Instrument · Extended range fuel tank · Automatic fuel
· Fuel heater · Alternator Pre-heater · Bunded fuel tank feeding system
· PMG · Fuel T-valves
· Anti-damp and anti-corrosion
treatment
· Anti-condensation heater
· Winding and bearing RTD

Canopy Lub oil system Cooling System Control Panel

· Rental type · Oil Pre-heater · Front heat protection · Remote control panel
Canopy · Oil temp sensor · ATS
· Trailer · Synchronizing controller
· Adjustable ear th leakage
relay
Control Panel

Configuration Benefits

· Emergency stop button · Less wiring and components


· Integrated solution
· Protection MCB
· Less engineering and programming
· Battery charger · User friendly set-up and button layout
· Integrated aviation plug · Module can be configured to suit individual applications
· ATS connection · PC software for simplified configuration
· Digital control module · Wide range of communication capabilities

Operation conditions
Features
· Operation temp: -20 ˚C to + 70 ˚C
· Storage temp: -30 ˚C to + 80 ˚C
· Operating humidity: 95% w/o condensation
· Vibration: 5-25Hz , ±1.6 mm
5-1 00 Hz , a = 4g
· Shocks: a= 500m/s²

Options

· Ethernet interface (Remote monitoring and control)


· GSM modem/wireless internet (Remote monitoring and control)
· RS232-RS485 Dual por t interface
· Synchronizing control panel
· Distribution board with sockets kit and power busbar
· Battery trickle charge ammeter
· Ear th leakage protection
· Ear th fault protection
· Low fuel level alarm
· Low fuel level shutdown
· High fuel level alarm
· Fuel transfer system control
· Low coolant level shutdown
· High lube oil temp shutdown
· Overload via alarm switch on breaker
· Engine coolant heater controls
· Control panel heater
· S peed adjust switch
· Oil temp displayed on LCD screen
· Additional 8 inputs and outputs
Publication No. GYH0518N, ISSUE 1 @ AGG UK

AGG UK | AGG China | AGG USA | AGG UAE Distributed by

info@aggpower.co.uk | www.aggpower.co.uk

Follow us @facebook.com/aggpowergroup

Follow us @linkedin.com/company/agg-power

Follow us @ AGGPOWER

All information in the document is substantially correct a the time of printing


but may be subsequently altered by the company.

You might also like