3.12 Sampling Element: History Setup Dialog Box
3.12 Sampling Element: History Setup Dialog Box
Append Pressing Append button can add a history data. After the Append button is pressed, the
following Buffer Properties dialog box will display.
Read Address It is used to set the starting address for sampling the history data.
Border Color The below element background color is set to black and its border color is set to gray.
Background Color
Logging Buffer Use this option to set the number (No.1 ~ No.X) of history buffer for
reading the data of PLC corresponding address. The users can press
the History Buffer Setup button or click ”Option” > “History Setup”
(Choosing History Setup command from menu bar) to set the PLC
corresponding address.
Data Format Word
1. BCD
2. Signed BCD
3. Signed Decimal
4. Unsigned Decimal
5. Hex
6. Floating
Minimum It is used to set the minimum and maximum value of the display data,
i.e. the minimum and maximum value of Y-axis. If the read value is
Maximum more the maximum or less than the minimum, the system will display
the minimum and maximum value still.
Integral Digits Use this option to determine the digit number of integer and decimal
fraction. The digit number is not a real digit number value. It is only the
Fractional display format. The digit number will be a real decimal number only
Digits when the data format is selected as “Floating”.
Time/Date
Time Format Provide HH:MM:SS, HH:MM two kinds of formats.
Date Format Provide MM/DD/YY, DD/MM/YY and DD.MM.YY three kinds of formats.
Color When time or date format is selected, the users can use this option to
designate the display color.
Curve (No.1 ~ 8)
Enable If this option is selected, the following curve options are enabled and
can be set.
Data No. It is used to set the reading Word data when triggering every time. For
example, if the Data Length option in the History Setup dialog box is set
to 3words, there are 0 ~ 2 data numbers can be selected in this option.
When selecting 1, it indicates that this Curve 1 reads the data of the
Read Address+1 set in History Setup dialog box.
Please note that if the data format is selected as “Floating”, and
the Data Length option in the History Setup dialog box is an odd
numbers of words, ensure to set the Data No. as an even number.
Curve Width It is used to the display curve width. The range is within 1 ~ 8 and the
unit is pixel.
Curve Color It is used to the display curve color.
Grid Color Please refer to the figure below. The grid color is set to red and the grid number in
horizontal direction is set to 3.
Grid Number
Logging Buffer Use this option to set the number (No.1 ~ No.X) of history buffer for
reading the data of PLC corresponding address. The users can press
the History Buffer Setup button or click ”Option” > “History Setup”
(Choosing History Setup command from menu bar) to set the PLC
corresponding address.
Time/Date
Time Format Provide HH:MM:SS, HH:MM two kinds of formats.
Date Format Provide MM/DD/YY, DD/MM/YY and DD.MM.YY three kinds of formats.
Color When time or date format is selected, the users can use this option to
designate the display color.
Data No. (No. 1~8)
Date Length There are 16bits Word and 32bits Double Word two options.
Data Format There are following data format provided:
Word Double Word
1. BCD 1. BCD
2. Signed BCD 2. Signed BCD
3. Signed Decimal 3. Signed Decimal
4. Unsigned Decimal 4. Unsigned Decimal
5. Hex 5. Hex
6. Binary 6. Binary
7. Floating
Data No. It is used to set the reading Word data when triggering every time. For
example, if the Data Length option in the History Setup dialog box is set
to 3words, there are 0 ~ 2 data numbers can be selected in this option.
When selecting 1, it indicates that this Curve 1 reads the data of the
Read Address+1 set in History Setup dialog box.
Please note that if the data format is selected as “Floating”, and
the Data Length option in the History Setup dialog box is an odd
numbers of words, ensure to set the Data No. as an even number.
Integral Digits Use this option to determine the digit number of integer and decimal
fraction. The digit number is not a real digit number value. It is only the
Fractional display format. The digit number will be a real decimal number only
Digits when the data format is selected as “Floating”.
Text / Text Size The users can set the text, text size, font and text color that provided by
Font / Text Color Windows® to determine the text display on the element. (Please refer to Table
3.2.2 Property Description of General Buttons.)
Every input message in each state will be converted to a state value. The system
will list all input message in the event table.
Border Color The below element background color is set to light yellow and its border color is set
Background Color to black.
Logging Buffer Use this option to set the number (No.1 ~ No.X) of history buffer for
reading the data of PLC corresponding address. The users can
press the History Buffer Setup button or click ”Option” > “History
Setup” (Choosing History Setup command from menu bar) to set
the PLC corresponding address.
Data No. It is used to set the reading Word data when triggering every time.
For example, if the Data Length option in the History Setup dialog
box is set to 3words, there are 0 ~ 2 data numbers can be selected
in this option. When selecting 1, it indicates that this Curve 1 reads
the data of the Read Address+1 set in History Setup dialog box.
Time/Date
Time Format Provide HH:MM:SS, HH:MM two kinds of formats.
Date Format Provide MM/DD/YY, DD/MM/YY and DD.MM.YY three kinds of
formats.
Color When time or date format is selected, the users can use this option
to designate the display color.
1. D1000=0
2. D1000=1
3. D1000=2
4. D1000=3
5. D1000=4
6. D1000=5
7. D1000=6