QUESTIONER FOR EMS INTEGRATION:

Request information on Load Distribution Schematics of existing Electrical System as follows:

Sr No Description Details
1. Name / Location: REWARI IRD
2. HT Line Voltage: Only LT line
3. Transformer Rating: NIL(Power from RKPL Feeder)
4. Confirm Solar System is Installed & power Yes, 90 KW Capacity
consumed:
5. Solar system Ordering reference (Part Number) Tejas Solar( 17000224-OQ-
and Make. 11100)
6. If YES, Is the meter / Invertor provided with RS 485 Inverter
communicable Port.
7. Ampere & Type of Main LT Incomer: (TP or 4P) TP
8. Rating of Meters in Metering Compartment:
a. Confirm following Panels are Installed in common
MCC Room as follows:
b. Main In-comer Panel: INSTALLED
c. Main PMCC Panel: NOT INSTALLED
d. Main PDB Panel: INSTALLED
e. Main Lighting Panel: INSTALLED
f. Emergency Lighting Panel: INSTALLED
g. Details of any Other Panels / Distribution Boards
installed in MCC Room but not covered above:

DG Set:

Sr No Description Details
1. Confirm No of DG Set Installed with Ratings: 2( 100 KVA AND 400 KVA)
2. Confirm independent Panels are provided for each YES
DG Set
3. Details of each DG Control Panel w.r.t. Metering
devices provided as follows:
a. Details of Meters with quantity. KW METER-1, ENERGY
METER-1, BATTERY CHECK
METER-1 (FOR EACH DG)
b. Analog or Digital MFM Type 2-DIGITAL, 1- ANALOG (FOR
EACH DG)
c. Make & Model No UTOPIA GCU105
d. Meter cut-out size. 1.9 X 2.11
e. Is RS 485 communicable Port available in MFM NO
digital Meter.

Main In-comer PCC Panel:

Sr No Feeder Name Details


Dimensions of Panel: ( Length x Depth ) 193”X82”
I. In-comer:
a. Type & Rating of Switchgear: 1250 A
b. Details of Meters with quantity. AMMETER-1, VOLTMETER-1,
ENERGYMETER-1
c. Analog or Digital MFM Type DIGITAL
d. Make & Model No CN-CS 1250S1
e. Meter cut-out size. 1 X 2.8
f. Is RS 485 communicable Port available in MFM YES
digital Meter.

II. Out-Going Feeders:


a. Total No Of Feeders in Panel. a. 23
b. No of Spare / Vacant cubicle available. b. 4
Note: Details of all Out-going Feeders in the
Panel to be provided separately as per following
schedule:
1. Details of Feeder - 1:
a. Facility Name. HSD PUMP
b. Type & Rating of Switchgear 50KA
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T (DN2-250N)
f. Meter cut-out size. 1 X 2.8
g. Is RS 485 communicable Port available in MFM NA
digital Meter.

2. Details of Feeder - 2:
a. Facility Name. MS PUMP
b. Type & Rating of Switchgear 50KA
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T (DN2-250N)
f. Meter cut-out size. 1 X 2.8
g. Is RS 485 communicable Port available in MFM NA
digital Meter.
3. Details of Feeder - 3:
a. Facility Name. ETHANOL PUMP
b. Type & Rating of Switchgear 50KA
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T (DN2-250N)
f. Meter cut-out size. 1 X 2.8
g. Is RS 485 communicable Port available in MFM NA
digital Meter.

4. Details of Feeder - 4:
a. Facility Name. TAS PANEL
b. Type & Rating of Switchgear 50KA
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T (DN2-250N)
f. Meter cut-out size. 1 X 2.8
g. Is RS 485 communicable Port available in MFM NA
digital Meter.

5. Details of Feeder - 5:
a. Facility Name. EMERGENCY PANEL
b. Type & Rating of Switchgear 50KA
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T (DN2-250N)
f. Meter cut-out size. 1 X 2.8
g. Is RS 485 communicable Port available in MFM NA
digital Meter.

6. Details of Feeder - 6:
a. Facility Name. QC LAB
b. Type & Rating of Switchgear 50KA
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T (DN2-250N)
f. Meter cut-out size. 1 X 2.8
g. Is RS 485 communicable Port available in MFM NA
digital Meter.
7. Details of Feeder - 7:
a. Facility Name. PUMP HOUSE LIGHTING
b. Type & Rating of Switchgear 50KA
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T (DN2-250N)
f. Meter cut-out size. 1 X 2.8
g. Is RS 485 communicable Port available in MFM NA
digital Meter.

8. Details of Feeder - 8:
a. Facility Name. TK14 TOWER LIGHT
b. Type & Rating of Switchgear 50KA
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T (DN2-250N)
f. Meter cut-out size. 1 X 2.8
g. Is RS 485 communicable Port available in MFM NA
digital Meter.

9. Details of Feeder – 9:
a. Facility Name. PUMP 4,5
b. Type & Rating of Switchgear 50KA
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T (DN2-250N)
f. Meter cut-out size. 1 X 2.8
g. Is RS 485 communicable Port available in MFM NA
digital Meter.

Main PMCC Panel:

Sr No Feeder Name Details


Dimensions of Panel: ( Length x Depth )
I. Incomer with Quantities: NOT INSTALLED
a. Type & Rating of Switchgear:
b. Details of Meters with quantity.
c. Analog or Digital MFM Type
d. Make & Model No
e. Meter cut-out size.
f. Is RS 485 communicable Port available in MFM
digital Meter.
II. Out-Going Feeders:
a. Total No Of Feeders in Panel.
b. No of Spare / Vacant cubicle available.
Note: Details of all Out-going Feeders in the Panel
to be provided separately as per following
schedule:
1. Details of Feeder - 1:
a. Facility Name.
b. Type & Rating of Switchgear
c. Details of Meters with quantity.
d. Analog or Digital MFM Type
e. Make & Model No
f. Meter cut-out size.
g. Is RS 485 communicable Port available in MFM
digital Meter.

2. Details of Feeder - 2:
a. Facility Name.
b. Type & Rating of Switchgear
c. Details of Meters with quantity.
d. Analog or Digital MFM Type
e. Make & Model No
f. Meter cut-out size.
g. Is RS 485 communicable Port available in MFM
digital Meter.

3. Details of Feeder - 3:
4. Details of Feeder - 4:
5. Details of Feeder – 5, 6, 7, 8, etc. etc.

Main PDB Panel:

Sr No Feeder Name Details


Dimensions of Panel: ( Length x Depth ) 89”X74”
I. In-comer with Quantities:
a. Type & Rating of Switchgear: TP 125A
b. Details of Meters with quantity. AMMETER-1, VOLTMETER-1,
ENERGYMETER-1
c. Analog or Digital MFM Type DIGITAL
d. Make & Model No L&T DN2-250D
e. Meter cut-out size. 1.8 X 1.6
f. Is RS 485 communicable Port available in MFM NO
digital Meter.

II. Out-Going Feeders:


a. Total No Of Feeders in Panel. a. 9
b. No of Spare / Vacant cubicle available. b. 4
Note: Details of all Out-going Feeders in the Panel
to be provided separately as per following
schedule:
1. Details of Feeder - 1:
a. Facility Name. AIR COMPRESSOR- 1
b. Type & Rating of Switchgear 32A TP MCCB
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T DN2-250D
f. Meter cut-out size. 1 X1
g. Is RS 485 communicable Port available in MFM NO
digital Meter.

2. Details of Feeder - 2:
a. Facility Name. AIR COMPRESSOR- 2
b. Type & Rating of Switchgear 32A TP MCCB
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T DN2-250D
f. Meter cut-out size. 1 X1
g. Is RS 485 communicable Port available in MFM NO
digital Meter.

3. Details of Feeder - 3:
a. Facility Name. JOCKEY PUMP-1
b. Type & Rating of Switchgear 63A
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T DN2-250D
f. Meter cut-out size. 1 X1
g. Is RS 485 communicable Port available in MFM NO
digital Meter.

4. Details of Feeder - 4:
a. Facility Name. JOCKEY PUMP-2
b. Type & Rating of Switchgear 63A
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T DN2-250D
f. Meter cut-out size. 1 X1
g. Is RS 485 communicable Port available in MFM NO
digital Meter.

5. Details of Feeder - 5:
a. Facility Name. MOV PANEL
b. Type & Rating of Switchgear 63A
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T DN2-250D
f. Meter cut-out size. 1 X1
g. Is RS 485 communicable Port available in MFM NO
digital Meter.

Main Lighting Panel:

Sr No Feeder Name Details


Dimensions of Panel: ( Length x Depth ) 83”X42”
I. In-comer with Quantities:
a. Type & Rating of Switchgear: 250A
b. Details of Meters with quantity. NIL
c. Analog or Digital MFM Type NIL
d. Make & Model No OESA 250 D3
e. Meter cut-out size. 1.5X2
f. Is RS 485 communicable Port available in MFM NO
digital Meter.

II. Out-Going Feeders:


a. Total No Of Feeders in Panel. a. 5
b. No of Spare / Vacant cubicle available. b. 0
Note: Details of all Out-going Feeders in the Panel
to be provided separately as per following
schedule:
1. Details of Feeder - 1:
a. Facility Name. HIGH MAST TOWER
b. Type & Rating of Switchgear 32A
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T DN0-100C
f. Meter cut-out size. 1.3X1
g. Is RS 485 communicable Port available in MFM NO
digital Meter.

2. Details of Feeder - 2:
a. Facility Name. PUMP HOUSE TOWER
b. Type & Rating of Switchgear 32A
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T DN0-100C
f. Meter cut-out size. 1.3X1
g. Is RS 485 communicable Port available in MFM NO
digital Meter.

3. Details of Feeder - 3:
a. Facility Name. POWER-TURBO SHED
b. Type & Rating of Switchgear 32A
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T DN0-100C
f. Meter cut-out size. 1.3X1
g. Is RS 485 communicable Port available in MFM NO
digital Meter.

4. Details of Feeder - 4:
a. Facility Name. TANK POLE LIGHT
b. Type & Rating of Switchgear 32A
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T DN0-100C
f. Meter cut-out size. 1.3X1
g. Is RS 485 communicable Port available in MFM NO
digital Meter.

5. Details of Feeder - 5:
a. Facility Name. RETAIL OUTLET LIGHT
b. Type & Rating of Switchgear 32A
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T DN0-100C
f. Meter cut-out size. 1.3X1
g. Is RS 485 communicable Port available in MFM NO
digital Meter.

Main Emergency Panel:

Sr No Feeder Name Details


Dimensions of Panel: ( Length x Depth ) 110”X83”
I. In-comer with Quantities:
a. Type & Rating of Switchgear: 250A FP
b. Details of Meters with quantity. AMMETER-1, VOLTMETER-1,
ENERGYMETER-1
c. Analog or Digital MFM Type DIGITAL
d. Make & Model No L&T DN2-250D
e. Meter cut-out size. 1.8X1.6
f. Is RS 485 communicable Port available in MFM NO
digital Meter.

II. Out-Going Feeders:


a. Total No Of Feeders in Panel. a. 16
b. No of Spare / Vacant cubicle available. b. 3
Note: Details of all Out-going Feeders in the Panel
to be provided separately as per following
schedule:
1. Details of Feeder - 1:
a. Facility Name. MAIN LIGHTINING PANEL
b. Type & Rating of Switchgear 32A TP
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T DN0-100C
f. Meter cut-out size. 1.8X1
g. Is RS 485 communicable Port available in MFM NO
digital Meter.

2. Details of Feeder - 2:
a. Facility Name. FIRE WATER PUMP HOUSE
b. Type & Rating of Switchgear 32A TP
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T DN0-100C
f. Meter cut-out size. 1.8X1
g. Is RS 485 communicable Port available in MFM NO
digital Meter.
3. Details of Feeder - 3:
a. Facility Name. CONTROL ROOM
b. Type & Rating of Switchgear 32A TP
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T DN0-100C
f. Meter cut-out size. 1.8X1
g. Is RS 485 communicable Port available in MFM NO
digital Meter.

4. Details of Feeder - 4:
a. Facility Name. BOREWELL
b. Type & Rating of Switchgear 32A TP
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T DN0-100C
f. Meter cut-out size. 1.8X1
g. Is RS 485 communicable Port available in MFM NO
digital Meter.

5. Details of Feeder - 5:
a. Facility Name. HVLR
b. Type & Rating of Switchgear 32A TP
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T DN0-100C
f. Meter cut-out size. 1.8X1
g. Is RS 485 communicable Port available in MFM NO
digital Meter.

6. Details of Feeder - 6:
a. Facility Name. RIM SEAL UPS
b. Type & Rating of Switchgear 32A TP
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T DN0-100C
f. Meter cut-out size. 1.8X1
g. Is RS 485 communicable Port available in MFM NO
digital Meter.

7. Details of Feeder - 7:
a. Facility Name. TAS UPS
b. Type & Rating of Switchgear 32A TP
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T DN0-100C
f. Meter cut-out size. 1.8X1
g. Is RS 485 communicable Port available in MFM NO
digital Meter.

8. Details of Feeder – 8.:


a. Facility Name. FOAM MONITOR
b. Type & Rating of Switchgear 32A TP
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T DN0-100C
f. Meter cut-out size. 1.8X1
g. Is RS 485 communicable Port available in MFM NO
digital Meter.

9. Details of Feeder - 9:
a. Facility Name. OFFICE LIGHTING
b. Type & Rating of Switchgear 32A TP
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T DN0-100C
f. Meter cut-out size. 1.8X1
g. Is RS 485 communicable Port available in MFM NO
digital Meter.

10. Details of Feeder - 10:


a. Facility Name. CCTV SUPPLY
b. Type & Rating of Switchgear 32A TP
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T DN0-100C
f. Meter cut-out size. 1.8X1
g. Is RS 485 communicable Port available in MFM NO
digital Meter.

11. Details of Feeder - 11:


a. Facility Name. MCC ROOM
b. Type & Rating of Switchgear 32A TP
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T DN0-100C
f. Meter cut-out size. 1.8X1
g. Is RS 485 communicable Port available in MFM NO
digital Meter.

12. Details of Feeder - 12:


a. Facility Name. TT GANTRY
b. Type & Rating of Switchgear 32A TP
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T DN0-100C
f. Meter cut-out size. 1.8X1
g. Is RS 485 communicable Port available in MFM NO
digital Meter.

13. Details of Feeder - 13:


a. Facility Name. CAPACITOR BANK
b. Type & Rating of Switchgear 32A TP
c. Details of Meters with quantity. NIL
d. Analog or Digital MFM Type NIL
e. Make & Model No L&T DN0-100C
f. Meter cut-out size. 1.8X1
g. Is RS 485 communicable Port available in MFM NO
digital Meter.

Please note the following details are also required along with data’s of individual Panels /
Distribution Boards in above format for design of EMS scope of works:

1) Latest As-built SLD of Electrical load distribution system of the Installation.


2) Details of existing Ammeters installed on In-comer & Out-going Feeders of each Panel as
per above format is mandatorily required along with quantity of Spare Feeders.
3) Confirm whether LAN cable connections are presently available at MCC / PCC Rooms.
4) Recent copies of 2 months Electricity Bills to be provided.
5) Make of Solar system and Ordering reference (Part Number).
6) Any other information of existing electrical schematics which may help in design of CEMS.