RADIOGRAPHIC INTERPRETATION TABLE

DEFECTS MENTIONED ARE BASED ON 300mm (12") LONG WELD

WELD API II04 ASME B3I.3 API 620/650 ASME SECT.VIII ASME SECT. IX
S/N
DEFECT Pipe Line Process Piping TANK Boiler/Pressure Vessel WQT
1 SLAG Pipe OD>60.33mm(2") Severe Cyclic Cond. As per para UW51b in ASME VIII As per para UW51b in ASME VIII Linear Indications ESI
INCLUSION ESI >50.8mm L 1/3 TW a. 6.4MM for t up to 19mm a. 6.4MM for t up to 19mm a. 3.2mm for t<9.5mm
ESI >1.59mm W 2.5mm and TW/3 b. ⅓t for t from 19mm to 57.2mm b. ⅓t for t from 19mm to 57.2mm b. ⅓t for 9.5<t<57.2mm
ISI > 12.7mm AGG.L TW in any 12TW length c. 19mmfor t over 57.2mm c. 19mmfor t over 57.2mm c. 19mm for t>57.2mm
Pipe OD<60.33mm(2") Normal and Category Any group of slag inclusion in line
ESI >3xTWL M Fluid Services that have an AGG L greater than
ESI >1.59mm W 2 TWL t in a L of 12t, except when the
ISI > 2xTWL, ½xTWW 3mm and TW/2W distance between the successive
4TW in any 6" weld imperfections exceed 6L where L is
the L of the longest imperfection of
the group.
2 INSUFFICIENT IP >25.4mm L Severe Cyclic Cond.
PENETRATION AGG L >25.4mm NOT PERMITTED
AGG L >8% weld L Normal and Category
IPD >50.8MM L M Fluid Services NOT PERMITTED NOT PERMITTED NOT PERMITTED
AGG L >76.2mm Depth 1mm and 0.2TW
Cumulative Length 38mm
in any 6" weld L
3 LACK OF >25.4mm
NOT PERMITTED NOT PERMITTED NOT PERMITTED NOT PERMITTED
FUSION AGG L >8% weld L
4 POROSITY P CP Severe Cyclic Cond. Any Group of Aligned indications Any Group of Aligned indications a.20% of t or 3.2mm whichever is
>3.17mm Øcluster >12.7mm See BPV Code Sec VIII that have an AGG L greater than that have an AGG L greater than smaller ( including slag or tungsten
>25% TW AGG L >12.7mm App 4 t in a L of 12t, except when the t in a L of 12t, except when the as rounded indications with a length
Refer Chart Øpore >1.59mm Normal and Category distance between the successive distance between the successive 3x the width or less )
HB M Fluid Services imperfections exceed 6L, where L imperfections exceed 6L, where L b.For t less than 3.2mm the max no of
>12.7mm L For TW < 6mm is the length of the longest imper- is the length of the longest imper- rounded indications shall not exceed
AGG L >50.8mm same as above fections in the group. fections in the group. 12 in a 6" weld L
>6.35mm <50.8mm GAP For TW > 6mm Rounded Indications in excess of Rounded Indications in excess of c.For t>3.2mm Appendix l chart applies
AGG L >8% weld L Limit is x 1.5 that specified in BPV Code Sec VIII that specified in BPV Code Sec VIII
App 4 App 4

5 CRACK Star Crack >3.96mm NOT PERMITTED NOT PERMITTED NOT PERMITTED NOT PERMITTED
RADIOGRAPHIC INTERPRETATION TABLE
DEFECTS MENTIONED ARE BASED ON 300mm (12") LONG WELD

WELD API II04 ASME B3I.3 API 620/650 ASME SECT.VIII ASME SECT. IX
S/N
DEFECT Pipe Line Process Piping TANK Boiler/Pressure Vessel WQT
6 ROOT / CAP >50.8mm Severe Cyclic Cond.
UNDERCUT 1/6 of weld L NOT PERMITTED
Normal and Category NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED
M Fluid Services
1mm and TW/4
7 CONCAVE Density on rad image does not Total Joint Thickness
ROOT exceed that of thinnest base including weld reinfor- NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED
metal cement > TW
8 EXCESSIVE For TW(mm) Height(mm)
PENETRATION 6 1.5
NOT SPECIFIED >6 13 3 NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED
>13 25 4
>25 5
9 BURN TROUGH Pipe OD>60.33mm(2")
>6.35mm Dimension
>Thinner of TW
>12.7mm Separate Dimension
NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED
Pipe OD<60.33mm(2")
>6.35mm Dimension
>Thinner of TW
One BT of any size

LEGEND NOTE : i) Severe Cyclic Conditions (100% Line)


CODE DESCRIPTION ii) Normal & Category M Fluid Service (10% Line)
BPV Boiler Pressure Vessel
AGG Aggregate
TW Nominal Wall Thickness
L Length
W Width
t Thickness