Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Asset management program

Predictive maintenance

Anticipate future breakdowns thanks


to regular diagnosis of your equipment
You want to anticipate future electrical failures in order to ensure
optimum continuity of service on your site
The undesirable
Our expertise phenomena in electrical
distribution are:
For around thirty years Schneider Electric has studied all the
phenomena leading to malfunctions that might disrupt electrical
distribution @ Electrical
o Short-circuit
o Current overload
Your benefits o Overheating
Periodic diagnostics of your electrical equipment: o Partial discharge, etc
@ By skilled experts who have undergone regular training @ Mechanical
@ With specific manufacturer tools continuously updated and o Effect of wear on the operating
improved by regular feedback from our factories and on-site system
interventions o Effect of wear on the breaking system,
etc
Schneider Electric has your constraints into taken by developing two
kinds of diagnostics: @ Environmental
@ Diagnostics without Shut-down o Humidity/ventilation
@ Diagnostics with Shut-Down o Pollution, etc

Panorama of Schneider Electric diagnosis tools

MV

ProCorona

ProFusion

Surface discharges on
insulators

ProDiag Thermography
Diagnosis on an FG2
circuit-breaker using
ProSelect
ProDiag

LV Corona effects on a
charger
Panorama of Schneider Electric diagnosis tools
Predictive maintenance
without shut-down
Panorama of Schneider Electric diagnosis tools
Your needs MV
@ Ensure optimum continuity of service ProCorona
@ Cut down or eliminate shut-down times when performing
maintenance and diagnostic services ProFusion

ProDiag Thermography

ProSelect

LV
Panorama of Schneider Electric diagnosis tools

Your benefits
Diagnosis of your equipment without shut-down:
@ Low Voltage ; IR Thermography:
o Check of hot spots on Low Voltage busbars and connections
o Analysis of results by a qualified expert
o Recommendations set out formally in a report

Thermal analysis test on Low Voltage busbars

@ Medium Voltage ; ProCorona:


o Detection of partial surface discharges using ultrasound
o Audit of Medium Voltage cubicles and station
o Analysis of results by a qualified expert
o Recommendations set out formally in a report
We therefore take account of your increasingly restrictive operating Example of an
constraints. advanced corona-effect
phenomenon on Medium
Voltage insulators

Diagnostics of an Inter-
protection type VM6
cubicle using Procorona
Predictive maintenance
with shut-down
Panorama of Schneider Electric diagnosis tools

Your needs MV ProDiag

@ Guaranty the continuity of service of your electrical installation ProCorona


@ Anticipate future faults
@ Optimise your maintenance and diagnosis operations ProFusion

ProDiag Thermography

ProSelect

LV
Panorama of Schneider Electric diagnosis tools

Your benefits
In-depth diagnosis with shut-down of your MV/LV equipment:

@ Medium Voltage and Low Voltage ; ProDiag


o Study of the circuit-breaker and contactor drive chain

;
o Evaluation of the performance of circuit-breakers and contactors
using the ProDiag tool
o Analysis of results and trends by a expert who has undergone
regular training
o Recommendations set out formally in a report

@ Medium Voltage ; ProFusion


o Measurement of the resistance of Medium Voltage fuses

;
o Analysis and comparison of results by an expert
o Recommendations set out formally in a report

@ Low Voltage ; ProSelect


o Monitoring of the protection relay on LV circuit-breakers by current

;
injection
o Check of upstream-downstream discrimination
o Analysis of results by a qualified expert
o Recommendations set out formally in a report
Testimonials

Military

It was important for us to have optimum continuity of service


during reception/transmission periods for our submarines. In order
to ensure correct operation of the electrical installations on our
site during these phases, we asked Schneider Electric to perform
diagnostics on our HV-LV equipment.
We were satisfied and impressed with the astuteness of the tools
they developed. Following their intervention, we were completely
reassured by our equipment and were able to carry on activity with
much greater peace of mind.”

Schneider Electric Industries S.A.S


Head Office
35 rue Joseph Monier As standards, specifications and designs change from time to time, please ask for confirmation
CS 30323 of the information given in this publication.
92506 Rueil-Malmaison Design : Schneider Electric Industries S.A.S
www.schneider-electric.com Photos : Schneider Electric Industries S.A.S

SERED105011EN 12 / 2008