Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 12

Height of Column = 3.

4 m
width of Column = 0.6 m 0.4 m
Length of column = 0.4 m 0.4 m
Weight of Column = 20.4 kN

Length of B.Wall = 3.05 m


Length of B.Wall C/C = 3.55 m
Height of B Wall = 2.6 m
Width of B Wall = 0.15 m
Height above FGL = 0.12 m
Top of Footing below FGL = 0.7 m
Weight of B Wall = 29.74 kN
Height of gate = 2.7 m
Weight of wall on column = 14.87 kN
weight of Gate = 10 kN

CASE I- GATE CLOSED

Boundary Wall Closed Gate =Single Leaf

Length of Single Leaf = 5.86 m


Net Wind Pressure = 1.01 kN/m2
Wind force on Gate = 15.98 kN
Moment arm to the Footing = 2.17
Moment on base due to gate wind
force = 34.68 kNm
Boundary wall force due to wind = 5.45 kN
Moment on base due to boundary
Wall wind force = 11.55 kNm

Total Force (Hy) = 21.43 kN


Total Moment (My) = 46.23 kNm
Total Axial load(P) = 45.27 kN
Moment Mx (Gate load) = 32.3 kNm

CASE I- GATE OPEN


Gate Open

Boundary Wall
Net Wind Pressure = 1.01 kN/m2
Height of Column = 3.05 m
Moment Arm = 0.4 m
Moment Due to Gate = 29.3 kNm
Moment on base due to boundary
Wall wind force = 11.55 kNm
Total Force (Hy) = 5.45 kN
Total Moment (My) = 40.85 kNm
Total Axial load(P) = 45.27 kN
Moment Mx (Gate load) = 4 kNm
Height of Column = 3.4 m
width of Column = 0.6 m 0.4 m
Length of column = 0.4 m 0.4 m
Weight of Column = 20.4 kN

Length of B.Wall = 4.8 m


Length of B.Wall C/C = 5.0 m
Height of B Wall = 2.6 m
Width of B Wall = 0.15 m
Height above FGL = 0.12 m
Top of Footing below FGL = 0.7 m
Weight of B Wall = 46.80 kN
Height of gate = 2.7 m
Weight of wall on column = 23.40 kN
weight of Gate = 10 kN

CASE I- GATE CLOSED

Boundary Wall Closed Gate =Single Leaf

Length of Single Leaf = 4.8 m


Net Wind Pressure = 1.01 kN/m2
Wind force on Gate = 13.09 kN
Moment arm to the Footing = 2.17
Moment on base due to gate wind
force = 28.40 kNm
Boundary wall force due to wind = 7.35 kN
Moment on base due to boundary
Wall wind force = 15.59 kNm

Total Force (Hy) = 20.44 kN


Total Moment (My) = 43.99 kNm
Total Axial load(P) = 53.80 kN
Moment Mx (Gate load) = 27 kNm

CASE I- GATE OPEN


Gate Open
Boundary Wall
Net Wind Pressure = 1.01 kN/m2
Height of Column = 3.05 m
Moment Arm = 0.4 m
Moment Due to Gate = 24 kNm
Moment on base due to boundary
Wall wind force = 15.59 kNm
Total Force (Hy) = 7.35 kN
Total Moment (My) = 39.59 kNm
Total Axial load(P) = 53.80 kN
Moment Mx (Gate load) = 4 kNm
Height of Column = 3.4 m
width of Column = 0.6 m 0.4 m
Length of column = 0.4 m 0.4 m
Weight of Column = 20.4 kN

Length of B.Wall = 7m
Length of B.Wall C/C = 7.5 m
Height of B Wall = 2.6 m
Width of B Wall = 0.15 m
Height above FGL = 0.12 m
Top of Footing below FGL = 0.7 m
Weight of B Wall = 68.25 kN
Height of gate = 2.7 m
Weight of wall on column = 34.13 kN
weight of Gate = 10 kN

CASE I- GATE CLOSED

Boundary Wall Closed Gate =Single Leaf

Length of Single Leaf = 5.86 m


Net Wind Pressure = 1.01 kN/m2
Wind force on Gate = 15.98 kN
Moment arm to the Footing = 2.17
Moment on base due to gate wind
force = 34.68 kNm
Boundary wall force due to wind = 10.64 kN
Moment on base due to boundary
Wall wind force = 22.55 kNm

Total Force (Hy) = 26.62 kN


Total Moment (My) = 57.22 kNm
Total Axial load(P) = 64.53 kN 44.13
Moment Mx (Gate load) = 32.3 kNm

CASE I- GATE OPEN


Gate Open
Boundary Wall
Net Wind Pressure = 1.01 kN/m2
Height of Column = 3.05 m
Moment Arm = 0.4 m
Moment Due to Gate = 29.3 kNm
Moment on base due to boundary
Wall wind force = 22.55 kNm
Total Force (Hy) = 10.64 kN
Total Moment (My) = 51.85 kNm
Total Axial load(P) = 64.53 kN
Moment Mx (Gate load) = 4 kNm
Height of Column = 2.8 m
width of Column = 0.6 m 0.4 m
Length of column = 0.4 m 0.4 m
Weight of Column = 16.8 kN

Length of B.Wall = 4.74 m


Length of B.Wall C/C = 5.0 m
Height of B Wall = 2.6 m
Width of B Wall = 0.15 m
Height above FGL = 0.12 m
Top of Footing below FGL = 0.7 m
Weight of B Wall = 46.22 kN
Height of gate = 2.7 m
Weight of wall on column = 23.11 kN
weight of Gate = 10 kN

CASE I- GATE CLOSED

Boundary Wall Closed Gate =Single Leaf

Length of Single Leaf = 4.625 m


Net Wind Pressure = 1.06 kN/m2
Wind force on Gate = 13.24 kN
Moment arm to the Footing = 2.17
Moment on base due to gate wind
force = 28.72 kNm
Boundary wall force due to wind = 7.72 kN
Moment on base due to boundary
Wall wind force = 16.36 kNm

Total Force (Hy) = 20.95 kN


Total Moment (My) = 45.08 kNm
Total Axial load(P) = 49.91 kN
Moment Mx (Gate load) = 26.125 kNm

CASE I- GATE OPEN


Gate Open
Boundary Wall
Net Wind Pressure = 1.01 kN/m2
Height of Column = 3.05 m
Moment Arm = 0.4 m
Moment Due to Gate = 23.125 kNm
Moment on base due to boundary
Wall wind force = 16.36 kNm
Total Force (Hy) = 7.72 kN
Total Moment (My) = 39.48 kNm
Total Axial load(P) = 49.91 kN
Moment Mx (Gate load) = 4 kNm
Height of Column = 3.826 m
width of Column = 0.6 m
Length of column = 0.4 m
Weight of Column = 22.956 kN

Length of B.Wall = 4.76 m


Length of B.Wall C/C = 5.0 m
Height of B Wall = 2.6 m
Width of B Wall = 0.15 m
Height above FGL = 0.2 m
Top of Footing below FGL = 0.1 m
Weight of B Wall = 46.41 kN
Height of gate = 3.525 m
Weight of wall on column = 23.21 kN
weight of Gate = 12 kN

CASE I- GATE CLOSED

Boundary Wall Closed Gate =Single Leaf

Length of Single Leaf = 4.325 m


Net Wind Pressure = 1.1 kN/m2
Wind force on Gate = 16.77 kN
Moment arm to the Footing = 2.0625
Moment on base due to gate wind
force = 34.59 kNm
Boundary wall force due to wind = 8.01 kN
Moment on base due to boundary
Wall wind force = 12.81 kNm

Total Force (Hy) = 24.78 kN


Total Moment (My) = 47.40 kNm
Total Axial load(P) = 58.16 kN
Moment Mx (Gate load) = 29.55 kNm

CASE I- GATE OPEN


Gate Open
Boundary Wall
Net Wind Pressure = 1.1 kN/m2
Height of Column = 3.825 m
Moment Arm = 0.4 m
Moment Due to Gate = 25.95 kNm
Moment on base due to boundary
Wall wind force = 12.81 kNm
Total Force (Hy) = 8.01 kN
Total Moment (My) = 38.76 kNm
Total Axial load(P) = 58.16 kN
Moment Mx (Gate load) = 4.8 kNm
Height of Column = 3.15 m
width of Column = 0.2 m 0.4 m
Length of column = 1.2 m 0.4 m
Weight of Column = 18.9 kN

Length of B.Wall = 4.7 m


Length of B.Wall C/C = 5.0 m
Height of B Wall = 2.6 m
Width of B Wall = 0.15 m
Height above FGL = 0.12 m
Top of Footing below FGL = 0.7 m
Weight of B Wall = 45.83 kN
Height of gate = 2.7 m
Weight of wall on column = 22.91 kN
weight of Gate = 9 kN

CASE I- GATE CLOSED

Boundary Wall Closed Gate =Single Leaf

Length of Single Leaf = 4.8 m


Net Wind Pressure = 1.01 kN/m2
Wind force on Gate = 13.09 kN
Moment arm to the Footing = 2.17
Moment on base due to gate wind
force = 28.40 kNm
Boundary wall force due to wind = 6.83 kN
Moment on base due to boundary
Wall wind force = 14.47 kNm

Total Force (Hy) = 19.92 kN


Total Moment (My) = 42.88 kNm
Total Axial load(P) = 50.81 kN
Moment Mx (Gate load) = 22.5 kNm

CASE I- GATE OPEN


Gate Open
Boundary Wall
Net Wind Pressure = 1.01 kN/m2
Height of Column = 3.05 m
Moment Arm = 0.4 m
Moment Due to Gate = 21.6 kNm
Moment on base due to boundary
Wall wind force = 14.47 kNm
Total Force (Hy) = 6.83 kN
Total Moment (My) = 36.07 kNm
Total Axial load(P) = 50.81 kN
Moment Mx (Gate load) = 3.6 kNm