Professional Documents
Culture Documents
Huawei Router Layout and CME v1.0
Huawei Router Layout and CME v1.0
Location Equipment
ATN910C-G
PE ACCESS-L2
ATN910D-A
Unified SDN Platform ATN950D
PE ACCESS-L1 NE8000 M8
NE8000 M14
NE8000-M8
PE AGG NE8000-M14
NE8000-X8
NE8000-M14
PE CORE NE8000-X8
NE9000-20
Page 1
ATN NE8000 NE9000
ATN 910C-G
ATN 910C-G
Dimensions (WxDxH) • 442mm×220mm×44.45mm(1U)
• Maximum:94.5W
Power consumption
• Typical:74.8W
AC Power
Temperature • -40℃~65℃
Page 2
ATN NE8000 NE9000
ATN 910D-A
Temperature • -40℃~65℃
880Gbps, 1U, 220mm
Page 3
ATN NE8000 NE9000
ATN 950D
Temperature -40℃~65℃
Page 4
ATN NE8000 NE9000
Service Slot 8 14 8
Height 3U 5U 15.8U
Page 5
ATN NE8000 NE9000
MPU * 2
Chassis body dimensions:
704 mm (15.8 U) x 442 mm x 874 mm
Dimensions (H x W x D)
15.8U SFU * 8 Maximum dimensions:
704 mm (15.8 U) x 442 mm x 990 mm
LPU * 8 Typical power
10256W
consumption
Forwarding
FAN Tray * 3 1812 Mpps(LPUI-4T)
performance
Front View Back View Switching capacity 32 Tbps
Long term: 0°C to 45°C (for 4T or lower
MPU 9 MPU 10 1 2 3 4 5 6 7 8 Slot Slot Slot ID boards; Other boards are to be
LPU 8 Name Quantity determined and under test)
LPU 7 LPU 8 1–8
LPU 6
Short term: –5°C to +55°C (for 4T or lower
MPU 2 9–10 Operating temperature
S S S S S S S S boards; Other boards are to be
LPU 5
F F F F F F F F
LPU 4 U U U U U U U U
SFU 8 SFU1–SFU8 determined and under test)
LPU 3 Remarks: Restriction on the temperature
PM 10 PM1–PM10
LPU 2 variation rate: 30°C/hour
LPU 1 Fan 3 FAN1–FAN3
Front View Back View
Page 6
ATN NE8000 NE9000
PIU*2
IPU*2
IPU*2
PIU*4
• DC power will not occupy PIC slots, service slots can up to 14 PIC slots • AC power will occupy 4 PIC slots, service slots will be reduced, only has 10 PIC slots
Page 7
ATN NE8000 NE9000
Dimensions(W x D x H) 442mm×220mm×132.6mm(3U)
Slot View
1:1 System Capacity 1.2Tbps
IPU backup
Voltage DC:-40V to -72V AC:200 to 240V/100 to127V
Page 8
ATN NE8000 NE9000
Page 9
ATN NE8000 NE9000
Chassis system backup design Intra-system backup design Board internal backup design
Power module
Power modules: LPU Power supply Chip #1
Master Backup #1
Upper half chassis MPU fan
DC:N+1 monitoring monitoring
LPU area SFU external setting Chip #2
AC/HVDC:N+1 Power module
backup Fan assembly Chip #N
#N
3+1 backup
Dual monitoring planes, 1+1 backup Power modules, DC:N+1 backup,
Monitoring AC/HVDC:N+N backup
modules
1:1 backup
Master Slave LPU Clock A Chip #1
Monitoring
MPU MPU SFU Chip #2
SFU/MPU area Clock B
MPUs Fan assembly Chip #N
1:1 backup 3+1 backup
Dual management planes, 1+1 backup Clock modules, 1:1 backup
Page 10