Download as pdf or txt
Download as pdf or txt
You are on page 1of 10

Equipment Overview

Location Equipment
ATN910C-G
PE ACCESS-L2
ATN910D-A
Unified SDN Platform ATN950D
PE ACCESS-L1 NE8000 M8
NE8000 M14
NE8000-M8
PE AGG NE8000-M14
NE8000-X8
NE8000-M14
PE CORE NE8000-X8
NE9000-20

PE Core PE Core PE Core/PE Agg PE Agg/PE Acc L1 PE Agg/PE Acc L1 PE Acc L2


NE9000-20 NE8000-X8 NE8000-M14 NE8000-M8 ATN950D ATN910

Page 1
ATN NE8000 NE9000

ATN 910C-G

ATN 910C-G
Dimensions (WxDxH) • 442mm×220mm×44.45mm(1U)

Interface capability • 176G:16x10GE/GE/FE(o)+12xGE/FE(o)+4xGE/FE(e)

• DC: Dual pinput


Power
Dual input DC 16*10GE/GE/FE(o) 12*GE/FE(o) 4*GE/FE(e) • AC: Single input

• Integrated, 3 fans, 2+1 Backup, the wind blows from left


Fans
to right.

• Maximum:94.5W
Power consumption
• Typical:74.8W
AC Power
Temperature • -40℃~65℃

Page 2
ATN NE8000 NE9000

ATN 910D-A

Dimensions (WxDxH) • 442mm*220mm*44.45mm(1U)

System Capacity • 880G bps

Interface Density • 4*100GE/50GE + 16*25GE/10GE/GE + 8*10GE/GE/FE


1U
Power Input • Dual DC/AC, 1+1 backup
220mm

Power Consumption • 180W

• Integrated, 3 Fans, 2+1 backup, the wind blows from left to


Dual AC/DC 8*10GE/ 16*25GE/ 4*100GE/ Fans
right
GE/FE 10GE/GE/FE 50GE

Temperature • -40℃~65℃
880Gbps, 1U, 220mm

Page 3
ATN NE8000 NE9000

ATN 950D

160G, 6 Service Slots


220mm Dimensions(W x D x H) 442mm×220mm×88.9mm(2U)
DC
System Capacity 160G

2U Power 1+1 Backup

Power Consumption 210W


AC
1 fan board, 2 fans, 1+1 Backup, the wind blows
Fans
from left to right.

Temperature -40℃~65℃

Page 4
ATN NE8000 NE9000

NetEngine 8000 Portfolio Overview

Product Type NetEngine 8000 M8 NetEngine 8000 M14 NetEngine 8000 X8

System Capacity 1.2T/Chassis 2T/Chassis 4T/slot

Service Slot 8 14 8

Device Depth 220mm 220mm 874mm

Cabinet Requirement 300mm 300mm 1000mm

Height 3U 5U 15.8U

Airflow Design Left-to-right Left-to-right Front-to-back

Page 5
ATN NE8000 NE9000

NetEngine 8000 X8 Chassis Frame Layout


NetEngine 8000 X8 Key Component Backup: MPU 1+1 backup、Fan
Power Module * 10 Power Entry Module :20
inputs Redundancy、PM N+1 backup、SFU 7+1 backup

MPU * 2
Chassis body dimensions:
704 mm (15.8 U) x 442 mm x 874 mm
Dimensions (H x W x D)
15.8U SFU * 8 Maximum dimensions:
704 mm (15.8 U) x 442 mm x 990 mm
LPU * 8 Typical power
10256W
consumption
Forwarding
FAN Tray * 3 1812 Mpps(LPUI-4T)
performance
Front View Back View Switching capacity 32 Tbps
Long term: 0°C to 45°C (for 4T or lower
MPU 9 MPU 10 1 2 3 4 5 6 7 8 Slot Slot Slot ID boards; Other boards are to be
LPU 8 Name Quantity determined and under test)
LPU 7 LPU 8 1–8
LPU 6
Short term: –5°C to +55°C (for 4T or lower
MPU 2 9–10 Operating temperature
S S S S S S S S boards; Other boards are to be
LPU 5
F F F F F F F F
LPU 4 U U U U U U U U
SFU 8 SFU1–SFU8 determined and under test)
LPU 3 Remarks: Restriction on the temperature
PM 10 PM1–PM10
LPU 2 variation rate: 30°C/hour
LPU 1 Fan 3 FAN1–FAN3
Front View Back View

Page 6
ATN NE8000 NE9000

NetEngine 8000 M14 Chassis Frame Layout


M14 bundle with DC M14 bundle with AC
PIC*14 power FAN tray
PIC*10
power FAN tray

PIU*2
IPU*2
IPU*2

PIU*4

• DC power will not occupy PIC slots, service slots can up to 14 PIC slots • AC power will occupy 4 PIC slots, service slots will be reduced, only has 10 PIC slots

Capacity Max 2T, Evolved to 4.8T


Dimensions (W x D x H) 442mm * 220mm * 222mm(5U)
Weight(without cards) DC: 9KG; AC: 13.5KG
Typical power consumption DC: 905 W; AC: 968 W
Slot quantity DC: 14; AC: 10
Fan redundancy 3+1, short period at ambient temperature of 40°C if a single fan fails.
Power module redundancy DC: 1+1; AC: 2+2
0°C~45°C(long term)
Operating Temperature
-5°C~55°C(short term)

Page 7
ATN NE8000 NE9000

NetEngine 8000 M8 Basic Introduction

M8 bundle with DC power


Fan Module

Dimensions(W x D x H) 442mm×220mm×132.6mm(3U)
Slot View
1:1 System Capacity 1.2Tbps
IPU backup
Voltage DC:-40V to -72V AC:200 to 240V/100 to127V

1+1: DC Power Supply


Typical Power
DC:484W, AC:485W
Consumption
M8 bundle with AC power
DC: 8
7 PIC PIC 8 Service Slots
5 PIC PIC 6 AC: 6
10 IPU
Temperature -40℃~65℃
9 IPU
3 PWR PIC 4
1 PWR PIC 2

• AC power will occupy 2 PIC slots, service slots will be reduced,


only has 6 PIC slots

Page 8
ATN NE8000 NE9000

NetEngine 9000-20 Chassis Layout

Power Module * 24 Power Entry Module * 6


Size (W x D x H) 600mm x 1000mm x 2200mm
Central Monitor Unit * 2
Fan Module * 4
Weight (empty) 231kg

LPU *10 4T/Slot


Chassis Capacity
80T/Chassis
MPU * 1
49.5 U Fan Module * 2 Service slots 20

SFU *8 SFU 8(7+1 backup)


Fan Module * 2
MPU * 1 Typical energy
<0.4
efficiency(W/G)
LPU * 10 DC: N+1
Power supply
[Dual Input]AC/HVDC:N+1
Fan Module * 4

Chassis Appearance Slots layout


 Dimensions (H x W x D): 2200 mm x 600 mm x 1000 mm Slot Number Quantity Remarks
 Hardware Redundancy: MPU 1:1; SFU: 7+1, FAN Modules: 3+1 redundancy for each Heat 1 to 20 20 LPU Slots
Dissipation Area; DC Power Supply Modules: N+1, AC & HVDC Power Supply Modules: N+N
21 to 22 2 MPU Slots (1:1 backup mode)
23 to 30 8 SFU Slots (in 7 +1 load balancing mode)

Page 9
ATN NE8000 NE9000

Key component redundancy, improving reliability

Chassis system backup design Intra-system backup design Board internal backup design

Power module
Power modules: LPU Power supply Chip #1
Master Backup #1
Upper half chassis MPU fan
DC:N+1 monitoring monitoring
LPU area SFU external setting Chip #2
AC/HVDC:N+1 Power module
backup Fan assembly Chip #N
#N
3+1 backup
Dual monitoring planes, 1+1 backup Power modules, DC:N+1 backup,
Monitoring AC/HVDC:N+N backup
modules
1:1 backup
Master Slave LPU Clock A Chip #1
Monitoring
MPU MPU SFU Chip #2
SFU/MPU area Clock B
MPUs Fan assembly Chip #N
1:1 backup 3+1 backup
Dual management planes, 1+1 backup Clock modules, 1:1 backup

SFU SFU Chip A1 Chip B1


SFUs LPU
N+1 backup #1 #8
Lower half chassis LPU
area Chip An Chip Bn
Fan assembly
3+1 backup Inter-chip high-speed data bus, N+M
Inter-board high-speed data bus, N+M backup
backup

Page 10

You might also like