TEST ACCREDITATION
Manufacturer: Audio Alloy L.L.C.
Report Date: May 9, 2005
Test Date: April 14, 2005 For the scope of
Test Number: 05-0416 accreditation under NVLAP
code 200248-0
RESULT SUMMARY
PREPARED BY
STC=52 David M. Berg
CLIENT Orfield Laboratories, Inc.
th
2709 East 25 Street
ADDRESS
Minneapolis MN 55406
Audio Alloy, L.L.C.
Voice (612) 721-2455
Fargo, ND USA
FAX (612) 721-2457
Phone: (989) 832-1602
e-mail dave@orfieldlabs.com
email: tedwhite@audioalloy.com
The information included in the following report are the results of a sound
transmission class (STC) test conducted on one (1) interior wall assembly.
TEST RESULTS
50 400 45 6 0.62
500 47 5 0.40
630 49 4 0.50
40 800 54 0 0.40
1000 56 0 0.25
1250 57 0 0.25
30
1600 56 0 0.32
2000 52 4 0.44
20 TL 2500 52 4 0.35
STC Contour 3150 58 0 0.31
4000 64 0 0.49
10 5000 68 n/a 0.35
80
125
200
315
500
800
1250
2000
3150
5000
32
Frequency (Hz)
SPECIMEN DESCRIPTION
Representatives of the client constructed and installed the specimen into the
laboratory test opening. The specimen assembly consisted of the following:
Wall Structure
TEST METHOD
Data for test chamber flanking limits and reference specimen results are
available upon request.
T E S T R E P O R T
REMARKS
CONFIDENTIALITY
The client has full control over this information and any release of information
will be only to the client. The specific testing results are deemed to be
confidential exclusively for the client's use. Reproduction of this report, except
in full, is prohibited.