Professional Documents
Culture Documents
2010 NEW ELECTRIC DRWING - (New)
2010 NEW ELECTRIC DRWING - (New)
D D
Running contactor
Q Main power switch KMC Main control contactor PT KDY ★ Connedt to U, V, W of ELD
L1 U1 2 1 L1 T1 U3
R U
L2 V1 4 3 T2 V3
L2
S V
L3 W1 6 5 L3 T3 W3
T W
N
N ★ FUJI LIFT Inverter KDY Built-in
Control mainboard
COM4 PC-
J7-7 CM D+
PD+
D-
PD-
J2-2 X11 30B
J2-10 X19 Y1 HEIDENHAIN1387
J3-7 GND2 30C
CMY
J7-8 VB 12
J7-9 VS V2
31
KLZ
J7-10 GND3
32
11
CM P+
B B
A+ RZD Braking resistor
J8-7 3
A- DB
J8-8 4
B+ CN4
J8-9 1
B-
J8-10 2
Note : The wires which have ★ should be connected to the ELD ,if without ELD ,leave them.
When the traction machine is "Diana" series, there must be an electric brake release device
in the control cabinet, in that way, please connect the circuit which show "Applicable when
there is an electric brake release device" in the drawing.
A A
Design Draw No. TRA110
Check Main control Sheets 14
Approve circuit Sheet 1
Date Remark FUJI + synchronous motor
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
U1 V1 W1
2 3
KXX
D KYJ KYJ D
SZ2
2
U1 V1
★power interlock input ★power interlock input
U1a V1a
F1(3P6A)Control power breaker Main control contactor Running contactor Door lock relay Braking contactor
Connect when total floor number≥16
Braking contactor
T2 KMC KDY KMB KLZ KJR KLZ
43 44 44 43 1 2 2 1 2 1 4 3
R2 S2
RJ N
AC AC
Braking economic resistor
ZL1 注
TC1
Control power transformer F4(1P4A) + -
C 103(+) C
380V Brake
110VDC 102(-)
BK1 BK2
LZ
0VAC 220VAC 0VAC
110VAC ★Braking input power ★
d
X23- r
FR-2000-STB
J5-4 101 a
X22- J5-2
FR-2000-STB
SMn 504 2 1 4 3
505
B B
SM1 105
Landing door on 2nd floor
SXS Speed governor switch Note : The wires which have ★ should be connected to the ELD ,if without ELD ,leave them.
111
114
SNQ Safety gear switch
Opional
SDZ2 XDZ2 SXV XXV SDZ1 Bottom
XDZ1 Up door zone SXF CXF Emergency stop contactor
Brake
limit 1 Fireman switch
Emergency running Down limit zone
WK
Note: To be connected GJ SDF
L N FMG COM Button in M.R. SMQ XMQ KJT KMB KLZ
D when there are ELD and D
Switch power 5 Door interlock 31
2
43
photoelectric leveling switches 43
+5V -5V +24V-24V KBK1 KBK2
3 1 KDY
+24Va SMQa XMQa 32
★ JXa
119 120 121 122 123 124 XF KBK DF WK
+24V FMS FMX DMS DMX ★
★ Slow up in M.R.
Slow down in M.R. Slow up at car top
SMQ XMQ
JX MS MX
Slow down at car top
+5VGND3 +24VGND3 +24V GND2 X3 X4 X5 X6 X7 X8 X9 X10 X12 X13 X14 X15 X16 X17 X20 X21 X18
X0 X1 X2
J4-4 J4-3 J4-2 J4-1 J3-10 J3-7、8、9 J1-1 J1-2 J1-3 J1-4 J1-5 J1-6 J1-7 J1-8 J1-9 J1-10 J2-1 J2-3 J2-4 J2-5 J2-6 J2-7 J2-8 J3-1 J3-2 J2-9
FR2000-STB
For rear door
J6-10 J6-6 J6-9 J6-7 J6-8 J6-5 J6-1 J6-2 J6-3 J6-4 J5-1 J5-2 J5-3 J5-4 J5-9 J5-10 J4-5 J4-8 J4-9 J4-10 J4-6 J4-7
A1 A1 A1 A1
Main control contactor
4
Braking contactor
C KJT C
KJT
A2 A2 A2 A2
3
1
21
KYJ LD1 LD2
22
24T GND1 C+ C- CB+ CB- GND1
6 Connect when there is fire fighting function
KMB
5
CM1 KM2 GM2 KM GM
Connect when total floor number≥16
Safety, door lock circuit s testing Call box/COP Twin control/Group control
116 101 communication wire communication wire
When using Blue Light SJT-FZ,leave them For rear door For rear door
RS-485
1KAB2 2KAB2
Spcial use switch Bypass switch By attendant switch
Safety edge1
Safety edge2 RT- RT+ 24V CMM
SZY SZS SZH
J1-1J1-2 J1-3J1-4 J9-1 J9-8 J9-9 J9-5 J9-6 J10-6 J10-5 J9-3 J9-2 J9-4 J9-7 J10-1 J10-2 J9-10 J10-7 J10-8 J10-9 J10-10
NCZB
J11-1 J11-2 J11-3 J11-4 J11-7 J11-8 J11-5 J11-6 J2-4 J2-3 J2-2 J2-1 J3-4 J3-3 J3-2 J3-1 J4-4 J4-3 J4-2 J4-1 J5-4 J5-3 J5-2 J5-1 J6-4 J6-3 J6-2 J6-1
BLV+ BL1 ZM
yellow 13 +24V +24V +24V +24V
BEL Light control Overload light Door open button2 Door open holding button
+24V
red Door open button Door close button Door close button 2
A KZM CZD SKM1 SGM1 SKM2 SGM2 SKY A
F5(1P4A)
Arrival chime
KMD1 GMD1 KMD2 GMD2 KYD
Design Draw No. TRA110
black Door open light 2
BLV- 14 Door open light Door close light Door close light 2
Check Sheets 14
Approve Control circuit
+
Sheet 3
DC24V N L31 24V CMM BY1 BY2
Date Remark
TC1 Spare output Door open holding light
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A
Note : The wires which have ★ should be connected to the ELD ,if without ELD ,leave them. A
Door operator power supply terminals L/N shoud be connected to T2a and N when there is Design Draw No. TRA110
an ELD, but should be connected to 200 and 201 when there is no ELD. Check Sheets 14
Approve Control circuit
Sheet 4
Date Remark
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
When floor no. is above 30, cut off the power supply wire at the middle floor, otherwise connect it.
24T
GND1
C+
C-
D D
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
J1
J1
J1
J1
J1
NHTB
NHTB
NHTB
NHTB
NHTB
24V- 24V+
AVR3
J2
J3
J2
J3
J2
J3
J2
J3
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
+24V
+24V
+24V
+24V
+24V
+24V
200
+24V
+24V
201
C C
Text
Text
N floor down call N-1floor up call 3rd floor up call 3rd floor down call 2nd floor up call 2nd floor down call 1st floor up call
Elevator A Elevator B
CB+ CB+
J4 6 6
CB- CB- J4
BL-2000-STB 7 7 BL-2000-STB
8 GND1 GND1 8
J4 J4
5 8 9 10 5 8 9 10
GND1
GND1
Text
C+
C+
24T
C-
C-
24T
B B
1 2 3 4 1 2 3 4
4 4
J1 3 3
J1
Up call
J2 2 +24V 2
J2
1 1
NHTB NHTB
4 4
3 3
J3 Down call +24V
J3
2 2
A A
1 1
Design Draw No. TRA110
Check Sheets 14
Approve Landing call loop Sheet 5
Date Remark
When two elevator are twin controled and use one common landing call button ,connect the wire as per this drawing
and only connect the parallel wires.
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
D D
FR2000-STB
J4
10 9 8 5 J12 SN9
4
SN1 >
GND1
4 3
>
24T
Optional function
C-
3 2 +24V
1st floor car call ND1 JN1 ND9
+24V 2 1
1
NEB
SN2 SN16
4 4
3 3
2nd floor car call ND2
+24V
JN2 JE8 2 +24V
16th floor car call
2
ND16
C 1 > J2 1 C
NCZB
SN3 SN17
4 4
3 JN3 3
>
GND
3rd floor car call ND3 J1
C+
JE1 17th floor car call
+24
C-
4 3 2 1 +24V 2 2 +24V
J1 1
ND17
1
FR2000-CZB
COP 1 2 3 4 1 2 3 4
J10
Terminal NEB
7 8 9 10 J1
SN8
4 SN24
4
3
CMM
B
1
> J2 1
B
>
Weighing
A A
Design Draw No. TRA110
Check Sheets 14
Approve Car call loop
Sheet 6
Date Remark
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
F7 AVR2 BL2000-QKB
(4A)
L1 L 0V
J1-3
1L 1L 1L
J4-7 J1-7 J4-7 J4-7
J4-8 GND1 J1-8 J4-8 GND1 J4-8 GND1
GND1
GND1
GND1
CB+
CB-
CB-
CB+
CB-
CB+
Elevator A Elevator B Elevator H
DC5V/1.5A Power
Control cabinet
FR2000-STB SJT-YCJ
GND3
BL2000- YH H
3 3 YXZDB 6
4 +5V 4 7 YL L
Wire remote control system loop: J4 Monitor center
9 C+ 9
J1 J1 8 YG G
B B
10 C- 10
Network
(Every control cabinet use one of this)
FR2000-STB SJT-QIC/QID
GND3
BL2000- YH H
3 3 KIC/KID 6
IC/ID card management system loop : 4 +5V 4 7 YL L IC card reader
J4 Monitor center MF-500
9 C+ 9
J1 J1 8 YG G
GC-1 10 C- 10
1 2 3 4 Network
(IC/ID card network controller )
ID card reader
GND1
24T
C+
Control cabinet
C-
YX-K4-232
A A
Power
Design Draw No. TRA110
1 2 3 4 Check Sheets 14
J2 Optional function loop
Approve Sheet 7
BL2000-CIC/CID
Car IC/ID controller Date Remark
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
D D
Alarm
Call
EYJ
JL+ JL1
B1
C C
B2
B3
AC220V
B B
A A
Design Draw No. TRA110-B
Check Sheets 14
Approve Intercom loop
Sheet 8
Date
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
200
D
Top final limit switch SSJ
D
100
200
Bottom final limit switch SXJ
(Unit:mm )
Shelter board
H1
B B
UP DOWN
CB2
GC-4
Control cabinet
GC-7 CB3
D GC-1 GC-2 GC-3 D
Terminal Terminal CB5 CB5 CB5 Car top junction box Car top inspection box
XDZ XDZ SDT Door operator cable Power terminal
No. Mark No. Mark 100 1 2 TB7 DDZ
1 L31 31 U1 DC-1 DC-2 DC-3 105 1 116
JL+ No. Mark
2 L32 1 L31 1 24T 1
32 U1a 130 2 117 1 U1
2 JL1 DMS
3 N 33 V1 2 L31 2 GND1 3 3 T2a Connected to 200 and 201 2 V1
C+ 3 GND2/
4 GND2 34 V1a 3 N 3 2 when there is no ELD
1 DMX
4 N 3 W1
5 121 Limit 4 N 4 C- 4 DJ
35 116a 5 CMM 4 N
6 122 5 L33 5 105 5 110
36 118a 6 GMV1 5 U3
7 116 6 6 L313 6 111
37 115b 7 KMV1 6 V3
Door interlock 7 7 EM 7
8 117 38 115c MX 8 KAB 7 W3
9 118 8 8 FA 8
39 100b MS 9 KM
9 8
10 100 40 JXa 9 200 9 CMM
A A
Power box of light curtain
Design Draw No. TRA110
Check Sheets 14
Approve Car top circuit Sheet 10
BLV+
BLV-
BL1
Date Remark
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
D GC-7 GC-4 D
nF
Hoistway cable CB3
2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 1 2 3 4 5
24*0.75+1*2.0mm
Wire No.in
Plug No. drawing Cable No.
1 L31 1 114
113 SSJ
2 N 2 Pit HTB
121
3 3 GND2 SXV J1
Plug (171830-1) Pin(170308-1)
4 4 123 CH-4
GND2 SDZ1
5 119 5 Top terminal 2
119
6 121 6 Top limit GND2 SDZ2
7 123 7 Top terminal 1
117 Applicable when speed above 2.0m/s
8 120 8 Bottom terminal 2 NKTM
Control cabinet
1 24T 1 24T 1 Light and socket in pit Buffer SHC Pit emergency stop SKT and rope breakage switch SKS
2 GND1 2 GND1 2
GC-4 CH-4
1-480704-0 3 C+ 3 C+ 3
4 C- 4 C- 4
5 E Shield E
When there is a rear door opening on one floor or more ,sub-door landing call subcircuit and main door landing call subcircuit shuld be parallel connection.
When there is a rear door opening on one floor or more ,sub-door interlock subcircuit and main door interlock circuit should be serial connection.
A A
Design Draw No. TRA110-B
Check Sheets 14
Approve Hoistway circuit Sheet 11
Date Remark
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Plug(1-480705-0)
Plug(1-480705-0)
Plug(1-480705-0)
D
GC-1 2 GND1 shield 2 GND1 2 DC-11 2 GND1 shield 2 GND1 2 D
1-480704 1-480704 1-480704 1-480704
3 C+ shield 3 C+ 3 3 C+ shield 3 C+ 3
4 C- shield 4 C- 4 4 C- shield 4 C- 4
5 E shield E 5 5 E shield E 5
1 +24V white 1 +24V 1 1 CMM white 1 CMM 1
2 GND2 white 2 GND2 2 2 KMV1 white 2 KMV1 2
3 130 white 3 130 3 3 GMV1 white 3 GMV1 3
MS KAB
Control cabinet
4 MS 4 4 4
Car top
white 4 KAB white 4
Plug(172347-1)Pin (170308-1)
Plug(172347-1)Pin(170308-1)
Plug(172347-1) Pin(170308-1)
Plug(172347-1)Pin(170308-1)
5 MX white 5 MX 5 5 CZ white 5 CZ 5
Car top
GC-2 DC-10
COP
6 SMQa white 6 SMQa 6 6 MZ white 6 MZ 6
171358-1 171358-1
7 XMQa white 7 XMQa 7 7 KAB2 white 7 KAB2 7
8 CM1 white 8 CM1 8 8 KMV2 white 8 KMV2 8
C DC-2 JC-10 C
9 N orange 9 9 9 orang 9 9
Car top
orange 10 orange 10
Plug(171830-1)Pin(170308-1)
DC-3 JC-9
Car top
Plug(171830-1)Pin(170308-1)
Plug(171830-1)Pin(170308-1)
171364-1 171364-1
11 KM2 yellow 1 KM2 11 171364-1 11 yellow 1 11 171364-1
COP
Orange 11、12 earthed
Orange 11、12 earthed
JC11
Pin No. Wire No.
24T
Plug(1-480705-0)
1
Plug(350536-1)
2 GND1
3 C+
D 4 C- D
5 (E)
6 TVVP4
JC10 1 2 3 4
Pin No.Wire No. CH-4
1 CMM J9-1
2 KMV1 J9-2 J1 Car indicator
3 GMV1 J9-3 Open door 1 J1
KMD1
4 KAB J9-4 2
Plug(172347-1)Pin(170308-1)
J6-1 CH-4
5 CZ J9-5 3 J2 KYD
J6-2 1 2 3 4
6 MZ J9-6 SKM1
4 J6-3
7 KAB2 J9-7
J6-4 SKY
8 KMV2 J10-5
J10-6 Door open delay
9 GMV2 Close door
10 BLV+ J11-1 GMD1 1 J10-7 RT-
11 BL1 J11-2 2 RT+
12 N J11-3 3 J3 J10-8 RS-485
SGM1 J10-9 CMM Serial load communication
13 ZM CZD J11-4 4
C C
J10-10 24V
J11-7 J11-9
CZB
B 6 B4 B4 B
4 SN8
7 B5 B5
8 B6 B6
J1
J12
CZB-EB
J2
9
10
11
J1
12
105 SDC Emergency stop in car
13 105
14 106
106 CZB-EB
15 L33 J2
L33
FA SFA Fan
16 FA
EM SJM1
17 EM
18 JL+ JL+
19 JL1 JL1 JL
A 20 Alarm A
21 Design Draw No. TRA110
Note : Check Sheets 14
1. After the COP wiring is finished ,the plug should be made by the drawing. Approve COP wiring Sheet 13
2. The drawing is for BEST intercom ,Laogang intercom has different wire connection
,wire No. B1-B6. Date Remark
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
D
WS ELD Cable B1 WS ELD Cable B3 D
12*0.75 12*0.75
Wire No. in ELD Wire No. Pin No. Plug Pin No. Wire No. in Cable No. ELD Wire No. Pin No. Plug
Plug Pin No. drawing Cable No. Plug drawing
1 100 1 B1-1 1 1 U1 1 B3-1 1
2 115b 2 B1-2 2 2 V1 2 B3-2 2
3 100b 3 B1-3 3 3 W1 3 B3-3 3
4 115C 4 B1-4 4 4 N 4 B3-4 4
Control Cabinet
Control Cabinet
ELD
B1 B1
ELD
7 116a 7 B1-7 7 7 T2 7 B3-7 7
8 118a 8 B1-8 8 8 T2a 8 B3-8 8
9 GND2a 9 B1-9 9 9 U3a 9 B3-9 9
10 JXa 10 B1-10 10 10 V3a 10 B3-10 10
11 GND2 11 B1-11 11 11 BK1 11 B3-11 11
C C
12 JX 12 B1-12 12 12 BK2 12 B3-12 12
WS ELD Cable B2
12*0.75
Wire No. in
Plug Pin No. drawing Cable No. ELD Wire No. Pin No. Plug
1 +24V 1 B2-1 1
B B
2 +24Va 2 B2-2 2
3 GND2 3 B2-3 3
115C 4 4 B2-4 4
Control Cabinet
5 SMQa 5 B2-5 5 Note: Control cabinet adopts sockets with 12 pin, cable adopts plugs with 12 jack.
6 SMQ 6 B2-6 6
B2 B2
ELD
7 XMQa 7 B2-7 7
8 XMQ 8 B2-8 8
9 CM1 9 B2-9 9
10 KM 10 B2-10 10
11 GM 11 B2-11 11
12 N 12 B2-12 12
A A
Design Draw No. TRA110
Check Sheets 14
Approve ELD plug Sheet 14
Date 2010.10.1
1 2 3 4 5 6 7 8