Download as pdf or txt
Download as pdf or txt
You are on page 1of 14

1 2 3 4 5 6 7 8

D D
Running contactor
Q Main power switch KMC Main control contactor PT KDY ★ Connedt to U, V, W of ELD
L1 U1 2 1 L1 T1 U3
R U
L2 V1 4 3 T2 V3
L2
S V
L3 W1 6 5 L3 T3 W3
T W
N
N ★ FUJI LIFT Inverter KDY Built-in

+OPC-LM1-PR Not applicable when there is an ELD


FR-2000-STB
PO +5V
CM 0V
PA+ A+

Y10 Up running PA- A-


J7-1 FWD
C Y11 Down running PB+ B+ C
J7-2 REV
CN3 PB- B-
J7-3 Y12 Release EN C+ PG
PC+
C-

Control mainboard
COM4 PC-
J7-7 CM D+
PD+
D-
PD-
J2-2 X11 30B
J2-10 X19 Y1 HEIDENHAIN1387
J3-7 GND2 30C
CMY
J7-8 VB 12
J7-9 VS V2
31
KLZ
J7-10 GND3
32
11
CM P+
B B
A+ RZD Braking resistor
J8-7 3
A- DB
J8-8 4
B+ CN4
J8-9 1
B-
J8-10 2

Note : The wires which have ★ should be connected to the ELD ,if without ELD ,leave them.
When the traction machine is "Diana" series, there must be an electric brake release device
in the control cabinet, in that way, please connect the circuit which show "Applicable when
there is an electric brake release device" in the drawing.
A A
Design Draw No. TRA110
Check Main control Sheets 14
Approve circuit Sheet 1
Date Remark FUJI + synchronous motor

  
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

U1 V1 W1

Applicable when there is an electric


Phase protection relay 503 501

2 3
KXX
D KYJ KYJ D

brake release device


1 4
1

SZ2
2
U1 V1
★power interlock input ★power interlock input
U1a V1a

F1(3P6A)Control power breaker Main control contactor Running contactor Door lock relay Braking contactor
Connect when total floor number≥16
Braking contactor
T2 KMC KDY KMB KLZ KJR KLZ
43 44 44 43 1 2 2 1 2 1 4 3
R2 S2
RJ N
AC AC
Braking economic resistor
ZL1 注
TC1
Control power transformer F4(1P4A) + -
C 103(+) C
380V Brake
110VDC 102(-)
BK1 BK2
LZ
0VAC 220VAC 0VAC
110VAC ★Braking input power ★
d
X23- r
FR-2000-STB

J5-4 101 a
X22- J5-2
FR-2000-STB

o Note: The brake voltage is according to the actual.


b
T
A2 A2
o
n 100a When brake voltage is DC220V, rectifier "ZL1" is connected.
200a KMB KJT i
M
a When brake voltage is AC220V, jump the "ZL1".
a
J5-3
i X23+ X22+ J5-1
m
A1 A1
n
o
T
b
o
F3(1P4A) 116 116a F2(1P4A)
a

r
d
SMJ Applicable when brake voltage is AC220/DC220V
KXX Phase sequence
201 200 100b
Car door switch ★
Safety circuit 100
115c
118a 117
★ ★
115b SDT SZ2 Applicable for Electric Brake Release of MRL Elevator
118 KYJ KYJ
Landing door on N floor

SJT Emergency stop in M.R. Emergency stop on car top 1 2


Landing door on 1st floor

SMn 504 2 1 4 3
505
B B
SM1 105
Landing door on 2nd floor

115a Main control contactor Connect when floor number≥16


SMn-1 SDC Running contactor Door lock relay Braking contactor Braking contactor
Emergency stop in car KMC KDY KMB KLZ KJR BK1 BK2 KLZ
SPS Jigger handwheel switch 43 44 44 2 Brake 3
43 1 2 1 2 1 LZ 4
SM2
115 110 106 RJ
D1 RLZ
SMn-2
GJ DJ SKT Braking economic resistor
Emergency running Inspection
Emergency stop in pit ★Braking input power ★Brake input power
SM3 SCS Up running overspeed switch
Door interlock loop

114a Applicable when brake voltage is DC110V


SKS Rope break-off switch

SXS Speed governor switch Note : The wires which have ★ should be connected to the ELD ,if without ELD ,leave them.
111
114
SNQ Safety gear switch

SSJ Top final limit Brake Contactor


A BLV+ A
KLZ
108 P+ C+ 5 6 Design Safety, Door Draw No. TRA110
113 Check Interlock, Brake 14
LCD Counter
Sheets
SXJ Bottom final limit
BLV-
Approve Circuit Sheet 2
SHC Buffer switch P- C-
Date Remark
109
     
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

200 201 Connect when there is fire fighting function


For elevator speed≥2.0m/s Fire fighting center

Thermal controller constant-close output


2 ★
GND2a GND2
DJ Electronic lock
3 1 Inspection box oncar top

Brake detecting switch


Locked when Break-off
DMG COM Button on Car Top Fire fighting motion
130 Top terminal 2 Bottom terminal 2Top limitBottom limitTop terminal 1 6 44
44

Opional
SDZ2 XDZ2 SXV XXV SDZ1 Bottom
XDZ1 Up door zone SXF CXF Emergency stop contactor
Brake
limit 1 Fireman switch
Emergency running Down limit zone

WK
Note: To be connected GJ SDF
L N FMG COM Button in M.R. SMQ XMQ KJT KMB KLZ
D when there are ELD and D
Switch power 5 Door interlock 31
2
43
photoelectric leveling switches 43
+5V -5V +24V-24V KBK1 KBK2
3 1 KDY
+24Va SMQa XMQa 32
★ JXa
119 120 121 122 123 124 XF KBK DF WK
+24V FMS FMX DMS DMX ★
★ Slow up in M.R.
Slow down in M.R. Slow up at car top
SMQ XMQ
JX MS MX
Slow down at car top

+5VGND3 +24VGND3 +24V GND2 X3 X4 X5 X6 X7 X8 X9 X10 X12 X13 X14 X15 X16 X17 X20 X21 X18
X0 X1 X2
J4-4 J4-3 J4-2 J4-1 J3-10 J3-7、8、9 J1-1 J1-2 J1-3 J1-4 J1-5 J1-6 J1-7 J1-8 J1-9 J1-10 J2-1 J2-3 J2-4 J2-5 J2-6 J2-7 J2-8 J3-1 J3-2 J2-9
FR2000-STB
For rear door
J6-10 J6-6 J6-9 J6-7 J6-8 J6-5 J6-1 J6-2 J6-3 J6-4 J5-1 J5-2 J5-3 J5-4 J5-9 J5-10 J4-5 J4-8 J4-9 J4-10 J4-6 J4-7

COM3 Y6 Y9 Y7 Y8 COM2 Y2 Y3 Y4 Y5 X22+ X22- X23+ X23- COM1 2H 2L


Y1 1H 1L

A1 A1 A1 A1
Main control contactor

2 KLZ KDY KJR KMC


Running contator

Economic resistor relay

4
Braking contactor

C KJT C
KJT
A2 A2 A2 A2
3
1
21
KYJ LD1 LD2
22
24T GND1 C+ C- CB+ CB- GND1
6 Connect when there is fire fighting function
KMB
5
CM1 KM2 GM2 KM GM
Connect when total floor number≥16
Safety, door lock circuit s testing Call box/COP Twin control/Group control
116 101 communication wire communication wire

When using Blue Light SJT-FZ,leave them For rear door For rear door
RS-485

24T GND1 C+ C- Serial weighing communication

1KAB2 2KAB2
Spcial use switch Bypass switch By attendant switch
Safety edge1
Safety edge2 RT- RT+ 24V CMM
SZY SZS SZH

B KQZ KKZ KCZ GMV1 KMV1


Note : The wires which have ★ should be connected to the ELD ,if without ELD ,leave them. B
KMZ GMV2 KMV2 Door close limit 1Door open limit 1
Safety edge 2
Light loadNo load Overload Full loadDoor close limit2Door open limit 2 1KAB1 2KAB1
Safety edge1
CMM GMV2 KMV2 GMV1 KMV1 KAB KAB2
QZ KZ CZ MZ

J1-1J1-2 J1-3J1-4 J9-1 J9-8 J9-9 J9-5 J9-6 J10-6 J10-5 J9-3 J9-2 J9-4 J9-7 J10-1 J10-2 J9-10 J10-7 J10-8 J10-9 J10-10

NCZB
J11-1 J11-2 J11-3 J11-4 J11-7 J11-8 J11-5 J11-6 J2-4 J2-3 J2-2 J2-1 J3-4 J3-3 J3-2 J3-1 J4-4 J4-3 J4-2 J4-1 J5-4 J5-3 J5-2 J5-1 J6-4 J6-3 J6-2 J6-1

BLV+ BL1 ZM
yellow 13 +24V +24V +24V +24V
BEL Light control Overload light Door open button2 Door open holding button
+24V
red Door open button Door close button Door close button 2
A KZM CZD SKM1 SGM1 SKM2 SGM2 SKY A
F5(1P4A)
Arrival chime
KMD1 GMD1 KMD2 GMD2 KYD
Design Draw No. TRA110
black Door open light 2
BLV- 14 Door open light Door close light Door close light 2
Check Sheets 14
Approve Control circuit
+
Sheet 3
DC24V N L31 24V CMM BY1 BY2
Date Remark
TC1 Spare output Door open holding light
         
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

201 For machine room less elevator U5


U
L31 N
D V V5 Door motor Car top light switch D
200 W5 SDM
W L311 Car top light EDM

T2 Car top socket XD


L T2a
FXS Pit light switch
N N ★ SKK
L312 Pit light EKM
PE

NCZB COP mainboard Pit lighting socket XK


Shenling VF
Door machine KMV1(5)
B2 J9-2 XG Control cabinet power socket
GMV1(6) Car light
XS1 XS2 B3 J9-3 KZM SJM1 EM
L33 EM1
CMM(4) J9-1
21 22
C2 C3
Car light switch
2 GM(3) Lighting control relay Car light
EM2
Speed governor motion Speed governor reset Car fan switch
1 KM (2)
SFA Car fan
FA
8 ★ FAN
C C
T2 N 8 CM1(1) Running contactor
KDY Control fan
13 14 FAN1
The No. in paranthesis is cable No. of Shenling door machine
Applicable when floor no. is above 6

Shaft light switch(M.R.) Shaft light switch(pit)


L32 SZMf SZMk N
UPS 2 1 1 2 ECM1
U U6
F6(1P4A) V V6 Door motor Shaft light
503 502 501 W6
W
2 3 3 2 ECMn
ELY traction machine emergency lighting
L T2a T2

XJC Monitor power socket N N ★


PE Safe lighting breaker

XTC detector power socket TD3200 VF Q1


B
NCZB L31 B
L3
Brake Release Contactor
Door machine
KMV2 J10-5
A2 PC1
A1 N N
KYJ GMV2 J10-6
Emergency Electric Operation GJ SZ1 PC2
Brake Release Button CMM
PAC J9-1
GM2 Q2
Applicable when brake CD L32
voltage is DC110V AC220V KM2
TC2 OD
AC110V ★ N
CM1 Shaft lighting breaker
COM
AC AC
ZL2
+ -
504 505

A
Note : The wires which have ★ should be connected to the ELD ,if without ELD ,leave them. A

Door operator power supply terminals L/N shoud be connected to T2a and N when there is Design Draw No. TRA110
an ELD, but should be connected to 200 and 201 when there is no ELD. Check Sheets 14
Approve Control circuit
Sheet 4
Date Remark

            
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

When floor no. is above 30, cut off the power supply wire at the middle floor, otherwise connect it.
24T
GND1

C+
C-

D D

1
2
3
4

1
2
3
4

1
2
3
4

1
2
3
4

1
2
3
4
J1

J1

J1

J1

J1
NHTB

NHTB

NHTB

NHTB
NHTB
24V- 24V+
AVR3

Applicable when floor no. is above 30.


L N

J2

J3

J2

J3

J2

J3

J2
J3
4
3
2
1

4
3
2
1

4
3
2
1

4
3
2
1

4
3
2
1

4
3
2
1

4
3
2
1

4
3
2
1
+24V

+24V

+24V

+24V

+24V

+24V
200

+24V

+24V
201

C C

Text
Text

N floor down call N-1floor up call 3rd floor up call 3rd floor down call 2nd floor up call 2nd floor down call 1st floor up call

Elevator A Elevator B
CB+ CB+
J4 6 6
CB- CB- J4
BL-2000-STB 7 7 BL-2000-STB
8 GND1 GND1 8
J4 J4
5 8 9 10 5 8 9 10
GND1

GND1
Text
C+

C+
24T
C-

C-
24T

B B

1 2 3 4 1 2 3 4
4 4
J1 3 3
J1
Up call
J2 2 +24V 2
J2
1 1

NHTB NHTB
4 4
3 3
J3 Down call +24V
J3
2 2
A A
1 1
Design Draw No. TRA110
Check Sheets 14
Approve Landing call loop Sheet 5
Date Remark
When two elevator are twin controled and use one common landing call button ,connect the wire as per this drawing
and only connect the parallel wires.        
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

D D

FR2000-STB
J4
10 9 8 5 J12 SN9
4
SN1 >
GND1

4 3
>
24T

J1 JE1 9th floor car call


C+

Optional function
C-

3 2 +24V
1st floor car call ND1 JN1 ND9
+24V 2 1
1
NEB
SN2 SN16
4 4
3 3
2nd floor car call ND2
+24V
JN2 JE8 2 +24V
16th floor car call
2
ND16
C 1 > J2 1 C

NCZB
SN3 SN17
4 4
3 JN3 3
>
GND
3rd floor car call ND3 J1

C+
JE1 17th floor car call
+24

C-
4 3 2 1 +24V 2 2 +24V
J1 1
ND17
1
FR2000-CZB
COP 1 2 3 4 1 2 3 4
J10
Terminal NEB
7 8 9 10 J1
SN8
4 SN24
4
3
CMM

8th floor car call 3


Voice announcer ND8 JN8
RT+
24V
RT-

Car indicator +24V


2 JE8 +24V
24th floor car call
2
ND24

B
1
> J2 1
B

>
Weighing

A A
Design Draw No. TRA110
Check Sheets 14
Approve Car call loop
Sheet 6
Date Remark

    
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

F7 AVR2 BL2000-QKB
(4A)
L1 L 0V
J1-3

Group control board


AC220V
N N +5V J1-4
D D
FR-2000-STB FR-2000-STB FR-2000-STB

J4-6 1H J1-6 J4-6 1H J4-6 1H

1L 1L 1L
J4-7 J1-7 J4-7 J4-7
J4-8 GND1 J1-8 J4-8 GND1 J4-8 GND1

GND1

GND1

GND1
CB+
CB-

CB-

CB+

CB-
CB+
Elevator A Elevator B Elevator H

Group control system loop:

The terminal can be placed near to the control cabinet


Suggest that there be no radiation equipment nearby
SJT-WJ Monitor center 1
FR2000-STB SJT-WK
C 4 +5V 5V C

8 GND3 GD DC5V/1.5A Power


J4 C+
9 H
Wireless remote control system loop:
10 C- L
SJT-WJ Monitor center 2
Wireless network

DC5V/1.5A Power
Control cabinet

FR2000-STB SJT-YCJ
GND3
BL2000- YH H
3 3 YXZDB 6
4 +5V 4 7 YL L
Wire remote control system loop: J4 Monitor center
9 C+ 9
J1 J1 8 YG G
B B
10 C- 10
Network
(Every control cabinet use one of this)

Control cabinet Note:one monitor system use one data collector


Power it can monitor several elevators.

FR2000-STB SJT-QIC/QID
GND3
BL2000- YH H
3 3 KIC/KID 6
IC/ID card management system loop : 4 +5V 4 7 YL L IC card reader
J4 Monitor center MF-500
9 C+ 9
J1 J1 8 YG G
GC-1 10 C- 10
1 2 3 4 Network
(IC/ID card network controller )
ID card reader
GND1
24T

C+

Control cabinet
C-

YX-K4-232
A A

Power
Design Draw No. TRA110
1 2 3 4 Check Sheets 14
J2 Optional function loop
Approve Sheet 7
BL2000-CIC/CID
Car IC/ID controller Date Remark
          
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

D D

Power supply box Main unit in Sub-unit in cabin


Main unit in MR Main unit on car top Main unit in pit
AC220V Alarm Light Phone guard room Black Blue
+ - + - + - + - R L + - R L + - R L + - R L Red Yellow
JL-

Alarm

Call
EYJ
JL+ JL1

B1
C C
B2

B3
AC220V

Intercom for 5 ways

B B

A A
Design Draw No. TRA110-B
Check Sheets 14
Approve Intercom loop
Sheet 8
Date
        
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

200

D
Top final limit switch SSJ
D

100

Top limit switch SSV

Top terminal switch SSD *1

Top sub-terminal switch SSD2 *2

200
Bottom final limit switch SXJ

Bottom limit switch SXV


C C
100

Bottom sub-terminal switch SXD2


*2

Bottom terminal switch SXD


*1

Leveling position SMQ XMQ


H
Leveling zone switch SMQ XMQ Car

(Unit:mm )
Shelter board
H1

B B
UP DOWN

ELevator have to finish hoistway learning before high speed running.


The conditions below are neccesary before hoistway learning:
1.Top/bottom limit switch and top/bottom terminal switch are installed ,connection is correct. Speed
2.Up/down leveling zone switch and shelter board are installed ,connection is correct. Item 0.5m/s 1.0m/s 1.6m/s 2.0m/s 2.5m/s
3.Safety circuit and door interlock circuit are normal. *1 1000 1300 2500 2500 2500
4.General parameters and running parameters have been set. *2 4000 6250
5.Elevator can perform inspection running. H 180 180 230 230 230
6.If inverter is YASKAWA G7 and above 18.5KW ,please check if the junction of inverter braking unit in the H1 200 200 250 250 250
bottom left corner of the control cabinet is on 415V(Open the grey cover).
Before hoistway learning, the system should be in inspection state and elevator should press the bottom limit
switch.If elevator don't located at the bottom limit position,"To Down Limit"will be displayed
Press slow down button as to move the elevator to bottom limit.If elevator is at bottom limit and " Enter To Start" is
displayed(Elevator State:Up leveling zone X9 is valid,down leveling zone X10 takes off from
shelter board ),press "Enter" key,elevator starts to perform hoistway learning(Elevator state : bottom limit X6 is
reset ,then down leveling zone X10 come into the leveling zone).Hoistway learning stops at
A A
top limit (Elevator state:when arriving the top floor , up leveling zone X9 takes off from shelter board ,then top limit Design Draw No. TRA110
switch act )."Success" will be displayed if hoistway leaning is finished successfully.Please strictly
Check Signal collection Sheets 14
perform hoistway learning according to the steps above ,otherwise hoistway learning may fail."Failure LER=#" will
Approve system Sheet 9
be displayed if there is a fault,you should solve the problem by fault code at first.
If you want to escape from hoistway learning ,press "Esc" key,then "LER=15" displayed. Date Remark
       
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

CB2
GC-4
Control cabinet
GC-7 CB3
D GC-1 GC-2 GC-3 D

Terminal Terminal CB5 CB5 CB5 Car top junction box Car top inspection box
XDZ XDZ SDT Door operator cable Power terminal
No. Mark No. Mark 100 1 2 TB7 DDZ
1 L31 31 U1 DC-1 DC-2 DC-3 105 1 116
JL+ No. Mark
2 L32 1 L31 1 24T 1
32 U1a 130 2 117 1 U1
2 JL1 DMS
3 N 33 V1 2 L31 2 GND1 3 3 T2a Connected to 200 and 201 2 V1
C+ 3 GND2/
4 GND2 34 V1a 3 N 3 2 when there is no ELD
1 DMX
4 N 3 W1
5 121 Limit 4 N 4 C- 4 DJ
35 116a 5 CMM 4 N
6 122 5 L33 5 105 5 110
36 118a 6 GMV1 5 U3
7 116 6 6 L313 6 111
37 115b 7 KMV1 6 V3
Door interlock 7 7 EM 7
8 117 38 115c MX 8 KAB 7 W3
9 118 8 8 FA 8
39 100b MS 9 KM
9 8
10 100 40 JXa 9 200 9 CMM

COP cable CB9


C EDM 10 GM 9 C
11 114 10 201 10 KMV1 10 SDM
Safety 41 JX DC-9 L31 11 CM1 10
XD
12 115a 11 100 11 GMV1 11
42 KM N 12 (E)
13 115 DC-10 12 106 12 KAB 12
43 GM 13
14 130 Inspection 13 BL1 13
44 CM1 13 108 Remark 2 SMQ
15 DF Electronic lock DC-11 14 110 14 CZ 14
45 GND2a Remark 3 XMQ
16 B1 15 111 15 MZ 15
46 +24Va GND2 WECO light curtain
B2 16 Door operator cable1 connection
17 47 SMQa 16 116 16 +24V CB8
B3 17 17 111 SNQ
18 48 XMQa 17 117 KMV2 No. Mark Remark
Intercom 1 117A
18 GMV2 18 107 1
19 49 SMQ 18 GND2
2 117
GND2 19 KAB2 19 108 SNC 2 CMM Signal
20 50 XMQ 19 3 T2a Connected to 200 and 201
Brake detection 20 3 KAB
21 BKB 51 T2 20 130 20 CM1
4 N when there is no ELD
21 MZ KMZ 4 200
22 WK Temperature Detection
52 T2a 21 MS 21 KM2
5 CMM
CZ KCZ 5 PE
23 BK1 53 22 MX 22 GM2 22 Power
Brake 6 GMV2
23 CMM 6 201
24 BK2 54 23 SMQ 23 B1
B 7 KMV2 B
25 201 24 XMQ 24 B2 24 EM EM1
Optional 55 8 KAB2
26 XS1 56 25 BLV- 25 B3 25 EM2
For machine room less and 9 KM2
27 XS2 two direction speed governor 26 BLV+ 26 GND2a 26
57 FA
FAN 10 GM2
28 GND1 27 ZM 27 +24Va 27
58 11 CM1
29 CB+ twin control 59 28 CM1 28 T2a 28 N
12 (E)
30 CB- 29 KM 29 SMQa 29
60 JL1 ALARM 13
30 GM 30 XMQa 30
JL-

200 201 CMM KAB


Remark 1: Connected to GND2a when there is an ELD, otherwise connected to GND2
DZ-2 DC12/24V
Remark 2: Connected to SMQa when there is an ELD, otherwise connected to SMQ
Arrival chime L N COM A Remark 3: Connected to XMQa when there is an ELD, otherwise connected to XMQ
Black(-) Red(+) Yellow(spring)

A A
Power box of light curtain
Design Draw No. TRA110
Check Sheets 14
Approve Car top circuit Sheet 10
BLV+
BLV-

BL1

Date Remark

         
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

D GC-7 GC-4 D
nF
Hoistway cable CB3
2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 1 2 3 4 5
24*0.75+1*2.0mm
Wire No.in
Plug No. drawing Cable No.
1 L31 1 114
113 SSJ
2 N 2 Pit HTB
121
3 3 GND2 SXV J1
Plug (171830-1) Pin(170308-1)

4 4 123 CH-4
GND2 SDZ1
5 119 5 Top terminal 2
119
6 121 6 Top limit GND2 SDZ2
7 123 7 Top terminal 1
117 Applicable when speed above 2.0m/s
8 120 8 Bottom terminal 2 NKTM
Control cabinet

nth floor door lock


9 122 9 Bottom limit E
GC-7 10 124 10 Bottom terminal 1
C 171364-1
11 GND2 11 3KTM 2F C
2KTM 3th floor door lock
12 108 12 Bottom final limit
E
13 114 13 Top final limit
2KTM
14 117 14
Door interlock 1KTM 2nd floor door lock
15 118 15 E HTB
16 XF 16 Fire switch J1
1KTM
17 DF 17 Electronic lock 118 CH-4
1st floor door lock
18 E Olivine Earthing E
Applicable when speed above 2.0m/s
19 111 19 Pit emergency 120
stop
20 106 20 GND2 XDZ2
21 124 1F
21
GND2 XDZ1
22 Intercom
122
23 GND2 XXV
24 108
B 109 SXJ B
DF HTB
GND2 DF
J1
XF CH-4
Landing call serial communication cableCB2 SXF
GND2
2*2P*0.75 spare
Wire No. in Wire No. in
Plug Pin No. drawing Cable No. drawing Pin No. Plug L31 N 109 113 E 111106
Control cabinet
Plug(1-480705-0)

1 24T 1 24T 1 Light and socket in pit Buffer SHC Pit emergency stop SKT and rope breakage switch SKS

2 GND1 2 GND1 2
GC-4 CH-4
1-480704-0 3 C+ 3 C+ 3
4 C- 4 C- 4
5 E Shield E

When there is a rear door opening on one floor or more ,sub-door landing call subcircuit and main door landing call subcircuit shuld be parallel connection.
When there is a rear door opening on one floor or more ,sub-door interlock subcircuit and main door interlock circuit should be serial connection.

A A
Design Draw No. TRA110-B
Check Sheets 14
Approve Hoistway circuit Sheet 11
Date Remark

         
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

Traveling cable CB5 COP cable CB9


36*0.75+4 core shield 36*0.75+4 core shield
Wire No. in Wire No. in Wire No. in Wire No. in
Plug Pin No. drawing Cable No. drawing Pin No. Plug Plug Pin No. drawing Cable No. drawing Pin No. Plug

1 24T Shield 1 24T 1 1 24T shield 1 24T 1


DC-1 JC-11
Plug(1-480705-0)

Plug(1-480705-0)

Plug(1-480705-0)

Plug(1-480705-0)
D
GC-1 2 GND1 shield 2 GND1 2 DC-11 2 GND1 shield 2 GND1 2 D
1-480704 1-480704 1-480704 1-480704
3 C+ shield 3 C+ 3 3 C+ shield 3 C+ 3
4 C- shield 4 C- 4 4 C- shield 4 C- 4
5 E shield E 5 5 E shield E 5
1 +24V white 1 +24V 1 1 CMM white 1 CMM 1
2 GND2 white 2 GND2 2 2 KMV1 white 2 KMV1 2
3 130 white 3 130 3 3 GMV1 white 3 GMV1 3
MS KAB
Control cabinet

4 MS 4 4 4

Car top
white 4 KAB white 4

Plug(172347-1)Pin (170308-1)
Plug(172347-1)Pin(170308-1)

Plug(172347-1) Pin(170308-1)

Plug(172347-1)Pin(170308-1)
5 MX white 5 MX 5 5 CZ white 5 CZ 5

Car top
GC-2 DC-10

COP
6 SMQa white 6 SMQa 6 6 MZ white 6 MZ 6
171358-1 171358-1
7 XMQa white 7 XMQa 7 7 KAB2 white 7 KAB2 7
8 CM1 white 8 CM1 8 8 KMV2 white 8 KMV2 8
C DC-2 JC-10 C

9 KM KM 9 171358-1 9 GMV2 white 9 GMV2 9 171358-1


white 9
GM GM BLV+ BLV+
10 white 10 10 10 white 10 10
BLV- BLV- BL1
11 white 11 11 11 BL1 white 11 11
BLV+ BLV+ N
12 white 12 12 12 N white 12 12
13 ZM yellow 12 ZM 13 13 ZM yellow 12 ZM 13
1 100 orange 1 100 1 1 orange 1 1
2 106 orange 2 106 2 2 orange 2 2
3 108 orange 3 108 3 3 B1 orange 3 B1 3
4 110 orange 4 110 4 4 B2 orange 4 B2 4
5 111 orange 5 111 5 5 B3 orange 5 B3 5
6 116 orange 6 116 6 6 orange 6 6
B B

7 117 orange 7 117 7 7 orange 7 7


8 L31 orange 8 L31 8 8 orange 8 8
N
Control cabinet

9 N orange 9 9 9 orang 9 9
Car top

GC-3 10 L33 L33 10 DC-9 10 10


Plug(171830-1) Pin(170308-1)

orange 10 orange 10
Plug(171830-1)Pin(170308-1)

DC-3 JC-9
Car top
Plug(171830-1)Pin(170308-1)

Plug(171830-1)Pin(170308-1)
171364-1 171364-1
11 KM2 yellow 1 KM2 11 171364-1 11 yellow 1 11 171364-1

COP
Orange 11、12 earthed
Orange 11、12 earthed

12 GM2 yellow 2 GM2 12 12 yellow 2 12


13 yellow 3 13 13 105 yellow 3 105 13
14 200 200 14 14 106 14
yellow 4 106 yellow 4

15 201 yellow 5 201 15 15 L33 yellow 5 L33 15


16 B1 yellow 6 B1 16 16 FA yellow 6 FA 16
17 B2 yellow 7 B2 17 17 EM yellow 7 EM 17
A A
18 B3 yellow 8 B3 18 18 JL+ yellow 8 JL+ 18 Design Draw No. TRA110-B
GND2a JL1
Check Sheets 14
19 yellow 9 GND2a 19 19 JL1 yellow 9 19 Traveling cable
Approve Sheet 12
20 +24Va yellow 10 +24Va 20 20 yellow 10 20 Date Remark
21 T2a yellow 11 T2a 21 21 yellow 11 21           
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

JC11
Pin No. Wire No.
24T
Plug(1-480705-0)
1
Plug(350536-1)

2 GND1
3 C+
D 4 C- D
5 (E)
6 TVVP4

JC10 1 2 3 4
Pin No.Wire No. CH-4
1 CMM J9-1
2 KMV1 J9-2 J1 Car indicator
3 GMV1 J9-3 Open door 1 J1
KMD1
4 KAB J9-4 2
Plug(172347-1)Pin(170308-1)

J6-1 CH-4
5 CZ J9-5 3 J2 KYD
J6-2 1 2 3 4
6 MZ J9-6 SKM1
4 J6-3
7 KAB2 J9-7
J6-4 SKY
8 KMV2 J10-5
J10-6 Door open delay
9 GMV2 Close door
10 BLV+ J11-1 GMD1 1 J10-7 RT-
11 BL1 J11-2 2 RT+
12 N J11-3 3 J3 J10-8 RS-485
SGM1 J10-9 CMM Serial load communication
13 ZM CZD J11-4 4
C C
J10-10 24V
J11-7 J11-9
CZB

JC09 J10-10 J11-8


Pin Wire No. Open door CMM
1
1 KMD2
2
CZB-01 J9-1
2
SPARE J10-1 SZY Special
3 J4
SKM2 J10-2 SZS Bypass
4
SZH By attendant
J9-10
For rear door
1
Close door 1 ND1
GMD2 2
Intercom 2 JN1 3
1st floor car call
B1 (C.O.P.) 3 J5 SN1
B2 4
YELLOW(12V-) Call button SGM2 4
B3 BLUE(R)
RED
3 B1
BLACK 1
4 B2 ND8
2 8th floor car call
5 B3 JN8 3
Plug(171830-1) Pin(170308-1)

B 6 B4 B4 B
4 SN8
7 B5 B5
8 B6 B6
J1
J12
CZB-EB
J2
9
10
11
J1
12
105 SDC Emergency stop in car
13 105
14 106
106 CZB-EB
15 L33 J2
L33
FA SFA Fan
16 FA
EM SJM1
17 EM
18 JL+ JL+
19 JL1 JL1 JL
A 20 Alarm A
21 Design Draw No. TRA110
Note : Check Sheets 14
1. After the COP wiring is finished ,the plug should be made by the drawing. Approve COP wiring Sheet 13
2. The drawing is for BEST intercom ,Laogang intercom has different wire connection
,wire No. B1-B6. Date Remark
          
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

D
WS ELD Cable B1 WS ELD Cable B3 D

12*0.75 12*0.75
Wire No. in ELD Wire No. Pin No. Plug Pin No. Wire No. in Cable No. ELD Wire No. Pin No. Plug
Plug Pin No. drawing Cable No. Plug drawing
1 100 1 B1-1 1 1 U1 1 B3-1 1
2 115b 2 B1-2 2 2 V1 2 B3-2 2
3 100b 3 B1-3 3 3 W1 3 B3-3 3
4 115C 4 B1-4 4 4 N 4 B3-4 4

Control Cabinet
Control Cabinet

5 116 5 B1-5 5 5 U1a 5 B3-5 5


6 118 6 B1-6 6 6 V1a 6 B3-6 6
B3 B3

ELD
B1 B1

ELD
7 116a 7 B1-7 7 7 T2 7 B3-7 7
8 118a 8 B1-8 8 8 T2a 8 B3-8 8
9 GND2a 9 B1-9 9 9 U3a 9 B3-9 9
10 JXa 10 B1-10 10 10 V3a 10 B3-10 10
11 GND2 11 B1-11 11 11 BK1 11 B3-11 11
C C
12 JX 12 B1-12 12 12 BK2 12 B3-12 12

WS ELD Cable B2
12*0.75
Wire No. in
Plug Pin No. drawing Cable No. ELD Wire No. Pin No. Plug
1 +24V 1 B2-1 1
B B
2 +24Va 2 B2-2 2
3 GND2 3 B2-3 3
115C 4 4 B2-4 4
Control Cabinet

5 SMQa 5 B2-5 5 Note: Control cabinet adopts sockets with 12 pin, cable adopts plugs with 12 jack.
6 SMQ 6 B2-6 6
B2 B2
ELD

7 XMQa 7 B2-7 7
8 XMQ 8 B2-8 8
9 CM1 9 B2-9 9
10 KM 10 B2-10 10
11 GM 11 B2-11 11
12 N 12 B2-12 12

A A
Design Draw No. TRA110
Check Sheets 14
Approve ELD plug Sheet 14
Date 2010.10.1

1 2 3 4 5 6 7 8