Eternus Basic Config Guide

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 259

P3AG-3982-04ENZ0

FUJITSU Storage
ETERNUS DX S5 series
Hybrid Storage Systems

Configuration Guide (Basic)

Basic setup to start operations


Table of Contents

1. Configuration Workflow........................................................................................ 17
ETERNUS DX60 S5/DX100 S5/DX200 S5..................................................................................... 17
ETERNUS DX500 S5/DX600 S5/DX900 S5................................................................................... 20

2. Preparation........................................................................................................... 23
System Configuration Example................................................................................................. 23
Server Connection Preparation ................................................................................................. 24
Preparation and Setup for the Administration Terminal ........................................................... 24
LAN Connection Preparation for Operation Management......................................................... 25
Completing and Attaching the Network Setting Label .....................................................................................25

LAN Related Specifications...............................................................................................................................26

3. Rack Installation................................................................................................... 28
Power Distribution Unit Installation ......................................................................................... 30
Installing Power Distribution Unit (1U)............................................................................................................30

Installing Power Distribution Unit (2U)............................................................................................................32

Controller Enclosure Installation............................................................................................... 34


Drive Enclosure Installation...................................................................................................... 37
High-Density Drive Enclosure Installation ................................................................................ 40

4. Connecting Cables ................................................................................................ 46


Host Interface Cable Connection............................................................................................... 46
SFP+ Module Handling Instructions .................................................................................................................47

Drive Enclosure Connection ...................................................................................................... 50


Administration Terminal Connection ........................................................................................ 56
LAN Cable Connection (for Operation Management)................................................................ 57
Power Synchronized Unit Connection ....................................................................................... 58
Power Cord Connection............................................................................................................. 58
When No Power Distribution Units Are Installed ..............................................................................................58

When Power Distribution Units (1U) Are Installed ...........................................................................................59

When Power Distribution Units (2U) Are Installed ...........................................................................................61

When the DC Power Type Is Used .....................................................................................................................63

5. General Settings ................................................................................................... 65

2 Configuration Guide (Basic)


Table of Contents

Powering On............................................................................................................................. 67
Switching On and Off the Main Line Switch on the Power Distribution Unit.....................................................67

Switching On and Off the PSU Switch on the Power Supply Unit ......................................................................67

Powering On ....................................................................................................................................................70

Startup of ETERNUS Web GUI .................................................................................................... 73


When Using the Remote Installation Function.................................................................................................73

When Using the SSL (https) Connection...........................................................................................................73

Login ...............................................................................................................................................................74

Initial Setup.............................................................................................................................. 75
Initial Setup 1 ..................................................................................................................................................76

Firewall Settings ..............................................................................................................................................83

Initial Setup 2 (Optional).................................................................................................................................85

Smart Setup Wizard .......................................................................................................................................101

6. Configuration Settings for RAID Groups or Thin Provisioning............................. 108


How RAID Groups and Thin Provisioning Are Used.................................................................. 108
When Using Standard Volumes .............................................................................................. 108
RAID Group Creation ......................................................................................................................................109

Operation Volume Creation............................................................................................................................112

Hot Spare Registration...................................................................................................................................114

When Using SnapOPC+ (SDVs and SDPVs) .............................................................................. 117


Generation Management Volume (SDV) Creation..........................................................................................117

Copy Data Destination Volume (SDPV) Creation ............................................................................................118

When Using Thin Provisioning Volumes (TPVs) ...................................................................... 120


Thin Provisioning Configuration.....................................................................................................................120

Thin Provisioning Pool Creation .....................................................................................................................122

Volume Creation ............................................................................................................................................129

7. Host Interface Management .............................................................................. 133


LUN Group Addition................................................................................................................ 134
Modify Port Parameters.......................................................................................................... 137
Modify FC Port Parameters.............................................................................................................................137

Modify iSCSI Port Parameters .........................................................................................................................139

Modify SAS Port Parameters...........................................................................................................................143

CA Port Group Creation ........................................................................................................... 145


Set Host Response .................................................................................................................. 147

3 Configuration Guide (Basic)


Table of Contents

Add Host Groups..................................................................................................................... 148


Host Affinity Creation ............................................................................................................. 152
CA Reset Group Settings ......................................................................................................... 158

8. Monitoring Settings............................................................................................ 159


Event Notification Setup......................................................................................................... 159
Various Notification Settings .................................................................................................. 161
SNMP Trap Setup ...........................................................................................................................................161

E-mail Setup ..................................................................................................................................................167

Syslog Setup ..................................................................................................................................................169

Remote Support Setup............................................................................................................ 170


Remote Support (by AIS Connect) Setup ........................................................................................................171

Remote Support (by REMCS) Setup ................................................................................................................172

Audit Log Setup ...................................................................................................................... 174


Monitoring Server (SNMP Manager) Settings ......................................................................... 175
Transmission Test Execution................................................................................................... 176
SNMP Trap Test ..............................................................................................................................................176

Send Test E-mail ............................................................................................................................................177

9. Power Control Setup ........................................................................................... 179


Setup of the Auto Power Function and/or the Power Resume Function .................................. 179
Connection Setup for Power Synchronized Units..................................................................... 180
Wake On LAN Settings ............................................................................................................ 181

10. System Status Check ........................................................................................ 182


Checking the Component Status............................................................................................. 182
Checking the RAID Groups ...................................................................................................... 183
Checking the Volumes ............................................................................................................ 183
Checking the LUNs.................................................................................................................. 184
Powering Off........................................................................................................................... 185

11. Solution Configuration .................................................................................... 187


Business Continuity ................................................................................................................ 187
Remote Copy Operations for the Storage System (Copies between ETERNUS DX Storage Systems)................187

Automatic Switching Operation of the Storage Systems (Storage Cluster) .....................................................189

Storage Optimization ............................................................................................................. 190

4 Configuration Guide (Basic)


Table of Contents

Automated Storage Tiering ............................................................................................................................190

Performance/Tuning ......................................................................................................................................191

Green...................................................................................................................................... 193
Virtualization Platform ........................................................................................................... 195
Oracle VM Linkage .........................................................................................................................................195

VMware Linkage ............................................................................................................................................196

Veeam Storage Integration............................................................................................................................198

Microsoft Linkage ..........................................................................................................................................201

Security .................................................................................................................................. 202

A. Component Names............................................................................................. 204


Frontend Enclosures (ETERNUS DX900 S5) ............................................................................. 204
Front..............................................................................................................................................................204

Rear ...............................................................................................................................................................206

Component Names and LED Names...............................................................................................................207

Menu Operation Using the Panel Key ............................................................................................................212

Controller Enclosure ............................................................................................................... 216


Front..............................................................................................................................................................216

Rear ...............................................................................................................................................................219

Component Names and LED Names...............................................................................................................226

Drive Enclosure....................................................................................................................... 243


Front..............................................................................................................................................................243

Rear ...............................................................................................................................................................246

Component Names and LED Names...............................................................................................................248

Power Distribution Unit .......................................................................................................... 254


Power Distribution Units (1U)........................................................................................................................254

Power Distribution Units (2U)........................................................................................................................254

B. Structures for Host Connection........................................................................... 255

5 Configuration Guide (Basic)


List of Figures

Figure 1 System Configuration Example.................................................................................................................23


Figure 2 Network Setting Label..............................................................................................................................25
Figure 3 ETERNUS DX100 S5/DX200 S5 Rear View of a Controller (Reference)........................................................48
Figure 4 Connecting Cables between Enclosures (When Only One Controller Is Installed) .....................................50
Figure 5 Connecting Cables between Enclosures (When Two Controllers Are Installed) .........................................51
Figure 6 Administration Terminal Connection for Initial Setup...............................................................................56
Figure 7 Example of Creating Operation Volume and Backup Volume ...................................................................66
Figure 8 ON Position (Marked "|") of the Main Line Switches on a 1U Power Distribution Unit ..............................67
Figure 9 ON Position (Marked "|") of the Main Line Switches on a 2U Power Distribution Unit ..............................67
Figure 10 ON Position (Marked "|") of the PSU Switch on a Power Supply Unit ........................................................68
Figure 11 RAID Group Creation...............................................................................................................................109
Figure 12 Operation Volume Creation ....................................................................................................................112
Figure 13 Generation Management Volume (SDV) Creation ..................................................................................117
Figure 14 Copy Data Destination Volume (SDPV) Creation .....................................................................................118
Figure 15 Solution — Continuous Business (Copy between ETERNUS DX Storage Systems) .....................................187
Figure 16 Solution — Continuous Business (Storage Cluster) ..................................................................................189
Figure 17 Solution — Automated Storage Tiering....................................................................................................190
Figure 18 Solution — Performance/Tuning ..............................................................................................................192
Figure 19 Solution — Green.....................................................................................................................................193
Figure 20 Solution — Virtualization Platform (Oracle VM Linkage)..........................................................................195
Figure 21 Solution — Virtualization Platform (VMware Linkage).............................................................................196
Figure 22 Solution — Virtualization Platform (Veeam Storage Integration) ............................................................198
Figure 23 Solution — Virtualization Platform (Microsoft Linkage)...........................................................................201
Figure 24 Front View of a Frontend Enclosure (with a Front Cover)........................................................................204
Figure 25 Front View of a Frontend Enclosure (without a Front Cover)...................................................................205
Figure 26 Rear View of a Frontend Enclosure .........................................................................................................206
Figure 27 System Operation Panel .........................................................................................................................207
Figure 28 Message Format of the LCD Panel (during Startup)................................................................................208
Figure 29 Message Format of the LCD Panel (While Running) ...............................................................................209
Figure 30 Service Controller ...................................................................................................................................210
Figure 31 Power Supply Unit (Frontend Enclosure) ................................................................................................211
Figure 32 Frontend Routers....................................................................................................................................211
Figure 33 Front View of a 2.5" Type Controller Enclosure (ETERNUS DX60 S5/DX100 S5/DX200 S5)........................216
Figure 34 Front View of a 3.5" Type Controller Enclosure (ETERNUS DX60 S5/DX100 S5/DX200 S5)........................216
Figure 35 Front View of a Controller Enclosure (for the ETERNUS DX500 S5/DX600 S5, with a Front Cover) ...........217
Figure 36 Front View of a Controller Enclosure (for the ETERNUS DX500 S5/DX600 S5, without a Front Cover) ......217
Figure 37 Front View of a Controller Enclosure (for ETERNUS DX900 S5, with a Front Cover)..................................218
Figure 38 Front View of a Controller Enclosure (for ETERNUS DX900 S5, without a Front Cover) ............................218
Figure 39 Rear View of a Controller Enclosure (When the ETERNUS DX60 S5 Is installed with Only One
Controller)..............................................................................................................................................219
Figure 40 Rear View of a Controller Enclosure (When the ETERNUS DX60 S5 Is Installed with Two Controllers)......219
Figure 41 Rear View of a Controller Enclosure (When the ETERNUS DX100 S5/DX200 S5 Is Installed with
Only One Controller)...............................................................................................................................221

6 Configuration Guide (Basic)


List of Figures

Figure 42 Rear View of a Controller Enclosure (When the ETERNUS DX100 S5/DX200 S5 Is Installed with
Two Controllers) .....................................................................................................................................222
Figure 43 Rear View of a Controller Enclosure (ETERNUS DX500 S5) ......................................................................223
Figure 44 Rear View of a Controller Enclosure (ETERNUS DX600 S5) ......................................................................224
Figure 45 Rear View of a Controller Enclosure (ETERNUS DX900 S5) ......................................................................225
Figure 46 Operation Panel (ETERNUS DX60 S5/DX100 S5/DX200 S5) .....................................................................226
Figure 47 Operation Panel (Controller Enclosure for the ETERNUS DX500 S5/DX600 S5)........................................227
Figure 48 Operation Panel (Controller Enclosure [ETERNUS DX900 S5]) ................................................................228
Figure 49 2.5" Drives and 3.5" Drives .....................................................................................................................229
Figure 50 Controller (for the ETERNUS DX60 S5, Pattern 1)....................................................................................230
Figure 51 Controller (for the ETERNUS DX60 S5, Pattern 2)....................................................................................230
Figure 52 Controller (for the ETERNUS DX100 S5/DX200 S5, Pattern 1)..................................................................231
Figure 53 Controller (for the ETERNUS DX100 S5/DX200 S5, Pattern 2)..................................................................231
Figure 54 Controller (ETERNUS DX500 S5)..............................................................................................................232
Figure 55 Controller (ETERNUS DX600 S5)..............................................................................................................233
Figure 56 Controller (ETERNUS DX900 S5)..............................................................................................................234
Figure 57 Power Supply Unit (Controller Enclosure for the ETERNUS DX60 S5/DX100 S5/DX200 S5) (AC
Power Type) ...........................................................................................................................................235
Figure 58 Power Supply Unit (Controller Enclosure for the ETERNUS DX100 S5) (DC Power Type) ..........................235
Figure 59 Power Supply Unit (Controller Enclosure for the ETERNUS DX500 S5/DX600 S5/DX900 S5).....................236
Figure 60 Host Interface Ports (ETERNUS DX60 S5) ................................................................................................237
Figure 61 Host Interface Ports (ETERNUS DX100 S5/DX200 S5) ..............................................................................238
Figure 62 Host Interface Ports (ETERNUS DX500 S5/DX600 S5) ..............................................................................239
Figure 63 Host Interface (ETERNUS DX900 S5).......................................................................................................240
Figure 64 PFM ........................................................................................................................................................241
Figure 65 Batteries ................................................................................................................................................242
Figure 66 Front View of a 2.5" Type Drive Enclosure...............................................................................................243
Figure 67 Front View of a 3.5" Type Drive Enclosure...............................................................................................243
Figure 68 Front View of a High-Density Drive Enclosure.........................................................................................244
Figure 69 Top View of a High-Density Drive Enclosure with the Cover Opened.......................................................245
Figure 70 Rear View of a 2.5"/3.5" Type Drive Enclosure (When Only One I/O Module Is Installed).........................246
Figure 71 Rear View of a 2.5"/3.5" Type Drive Enclosure (When Two I/O Modules Are Installed) ............................246
Figure 72 Rear View of a High-Density Drive Enclosure..........................................................................................247
Figure 73 Operation Panel (Drive Enclosure) .........................................................................................................248
Figure 74 Disk Activity Panel (DAP)........................................................................................................................249
Figure 75 2.5" Drives and 3.5" Drives .....................................................................................................................250
Figure 76 I/O Module (Drive Enclosure)..................................................................................................................251
Figure 77 Power Supply Unit (Drive Enclosure) (AC Power Type)............................................................................252
Figure 78 Power Supply Unit (Drive Enclosure) (DC Power Type) ...........................................................................252
Figure 79 Fan Expander Module ............................................................................................................................253
Figure 80 Power Distribution Units (1U) ................................................................................................................254
Figure 81 Power Distribution Units (2U) ................................................................................................................254
Figure 82 Basic Concept of Host Connection (When Using Host Groups) ................................................................255

7 Configuration Guide (Basic)


List of Tables

Table 1 Server (Host) Environment.......................................................................................................................23


Table 2 LAN Port Availability.................................................................................................................................26
Table 3 Time Required to Turn the Power On ........................................................................................................70
Table 4 RAID Group Creation...............................................................................................................................109
Table 5 Operation Volume Creation ....................................................................................................................112
Table 6 Maximum Number of Pools, Maximum Pool Capacity, and Determined Chunk Size for Each Model.......122
Table 7 Recommended Patterns of Host Responses............................................................................................147
Table 8 The Number of Host Groups and Hosts That Can Be Registered..............................................................148
Table 9 ETERNUS DX Operation according to the Settings of the Auto Power Function and the Power
Resume Function....................................................................................................................................179
Table 10 Time Required to Turn the Power Off......................................................................................................185
Table 11 Volume Types That Can Be Used with Veeam Storage Integration..........................................................199
Table 12 Status and Meaning of Each LED (System Operation Panel) ..................................................................207
Table 13 Meaning of the Message on the LCD Panel (While Running) .................................................................209
Table 14 Name and Function of the Panel Key .....................................................................................................210
Table 15 Status and Meaning of Each LED (Power Supply Unit)............................................................................211
Table 16 Menu List for the LCD Panel ...................................................................................................................212
Table 17 Status and Meaning of Each LED (Operation Panel [Controller Enclosure for the ETERNUS DX60
S5/DX100 S5/DX200 S5])........................................................................................................................226
Table 18 Status and Meaning of Each LED (Operation Panel [Controller Enclosure for the ETERNUS
DX500 S5/DX600 S5]).............................................................................................................................227
Table 19 Status and Meaning of Each LED (Operation Panel [Controller Enclosure (ETERNUS DX900 S5)])..........229
Table 20 Status and Meaning of Each LED (Drive) ................................................................................................229
Table 21 Status and Meaning of Each LED (Controller for the ETERNUS DX60 S5).................................................230
Table 22 Status and Meaning of Each LED (Controller for the ETERNUS DX100 S5/DX200 S5) ..............................231
Table 23 Status and Meaning of Each LED (Controller for the ETERNUS DX500 S5/DX600 S5) ..............................233
Table 24 Status and Meaning of Each LED (Controller for the ETERNUS DX900 S5)...............................................234
Table 25 Status and Meaning of Each LED (Power Supply Unit [Controller Enclosure for the ETERNUS
DX60 S5/DX100 S5/DX200 S5])...............................................................................................................236
Table 26 Status and Meaning of Each LED (Power Supply Unit for the ETERNUS DX500 S5/DX600 S5/
DX900 S5) ..............................................................................................................................................236
Table 27 Status and Meaning of Each LED (Host Interface for the ETERNUS DX60 S5) ..........................................237
Table 28 Status and Meaning of Each LED (Host Interface for the ETERNUS DX100 S5/DX200 S5)........................238
Table 29 Status and Meaning of Each LED (Host Interface for the ETERNUS DX500 S5/DX600 S5)........................239
Table 30 Status and Meaning of Each LED (Host Interface for the ETERNUS DX900 S5) ........................................240
Table 31 Status and Meaning of Each LED (PFM) .................................................................................................241
Table 32 Status and Meaning of Each LED (Battery).............................................................................................242
Table 33 Status and Meaning of Each LED (Operation Panel [Drive Enclosure])...................................................248
Table 34 Status and Meaning of Each LED (Disk Activity Panel [DAP]) .................................................................249
Table 35 Status and Meaning of Each LED (Drive) ................................................................................................250
Table 36 Status and Meaning of Each LED (I/O Module [Drive Enclosure]) ...........................................................251
Table 37 Status and Meaning of Each LED (Power Supply Unit (Drive Enclosure))................................................252
Table 38 Status and Meaning of Each LED (Fan Expander Module)......................................................................253

8 Configuration Guide (Basic)


Preface

Fujitsu would like to thank you for purchasing the FUJITSU Storage ETERNUS DX60 S5/DX100 S5/DX200 S5,
ETERNUS DX500 S5/DX600 S5/DX900 S5 Hybrid Storage Systems (hereinafter referred to as ETERNUS DX).
The ETERNUS DX is designed to be connected to Fujitsu servers (Fujitsu SPARC Servers, PRIMEQUEST, PRIMERGY,
and other servers) or non-Fujitsu servers.
This manual describes the basic setup of the ETERNUS DX and how to start the operation.
This manual is intended for use of the ETERNUS DX in regions other than Japan.
Please carefully review the information outlined in this manual.

Copyright 2020 FUJITSU LIMITED


Fourth Edition
October 2020

9 Configuration Guide (Basic)


Preface

Trademarks
Third-party trademark information related to this product is available at:
https://www.fujitsu.com/global/products/computing/storage/eternus/trademarks.html

About This Manual


Intended Audience
This manual is intended for field engineers or storage system administrators who perform basic setups and start
operations.

Related Information and Documents


The latest version of this manual and the latest information for your model are available at:
https://www.fujitsu.com/global/support/products/computing/storage/manuals-list.html
Refer to the following manuals of your model as necessary:
"Site Planning Guide" "Design Guide" "Operation Guide (Basic)"
"Configuration Guide (Power Synchronized Unit)"
"Configuration Guide (Web GUI)" "Configuration Guide -Server Connection-" "Configuration/Operation Guide
(NAS)"
"ETERNUS Web GUI User's Guide"
"ETERNUS CLI User's Guide"

Document Conventions

■ Third-Party Product Names


• Oracle Solaris may be referred to as "Solaris", "Solaris Operating System", or "Solaris OS".
• Microsoft® Windows Server® may be referred to as "Windows Server".

■ Notice Symbols
The following notice symbols are used in this manual:

Indicates information that you need to observe when using the ETERNUS storage system. Make
sure to read the information.
Indicates information and suggestions that supplement the descriptions included in this
manual.

10 Configuration Guide (Basic)


Preface

Warning Signs
Warning signs are shown throughout this manual in order to prevent injury to the user and/or material damage.
These signs are composed of a symbol and a message describing the recommended level of caution. The
following explains the symbol, its level of caution, and its meaning as used in this manual.

This symbol indicates the possibility of serious or fatal injury if the ETERNUS DX is not used
properly.

This symbol indicates the possibility of minor or moderate personal injury, as well as damage to
the ETERNUS DX and/or to other users and their property, if the ETERNUS DX is not used properly.

This symbol indicates IMPORTANT information for the user to note when using the ETERNUS DX.

The following symbols are used to indicate the type of warnings or cautions being described.

The triangle emphasizes the urgency of the WARNING and CAUTION contents. Inside the
triangle and above it are details concerning the symbol (e.g. Electrical Shock).

The barred "Do Not..." circle warns against certain actions. The action which must be avoided
is both illustrated inside the barred circle and written above it (e.g. No Disassembly).

The black "Must Do..." circle indicates actions that must be taken. The required action is both
illustrated inside the black disk and written above it (e.g. Unplug).

How Warnings are Presented in This Manual


A message is written beside the symbol indicating the caution level. This message is marked with a vertical
ribbon in the left margin, to distinguish this warning from ordinary descriptions.
An example is shown below.

Example warning
Warning level indicator

Do
CAUTION Warning type indicator

• To avoid damaging the ETERNUS storage system, pay attention to the


following points when cleaning the ETERNUS storage system:
- Make sure to disconnect the power when cleaning.
- Be careful that no liquid seeps into the ETERNUS storage system Warning details
when using cleaners, etc.
- Do not use alcohol or other solvents to clean the ETERNUS storage system.

Warning layout ribbon

11 Configuration Guide (Basic)


Preface

Setting Procedures in This Manual


Detailed information about the setup parameters (descriptions and input conditions in the procedure) and the
status displays is described in "ETERNUS Web GUI User's Guide".
Note that the screen shots in this manual may be different from the actual screens.
Microsoft product screen shot(s) reprinted with permission from Microsoft Corporation.

Warning Labels and Manufacturer's Labels


Warning labels, manufacturer's labels, and a device ID label are found in the ETERNUS DX, as shown in the
example below.
Never remove these labels from the equipment or allow them to become dirty.

Frontend Enclosures

Device ID label
The model name and
Manufacturer's label
the serial number are
The model name and
listed.
the serial number are listed.

12 Configuration Guide (Basic)


Preface

Controller Enclosure
On the controller enclosure, warning labels and manufacturer's labels are attached to the top or to the left side.
• ETERNUS DX60 S5/DX100 S5/DX200 S5 (2.5" type / 3.5" type)

Manufacturer's label
The model name and
the serial number are listed.

Device ID label
The model name and
the serial number are listed.

13 Configuration Guide (Basic)


Preface

• ETERNUS DX500 S5/DX600 S5

Manufacturer's label
The model name and
the serial number are listed.

Device ID label
The model name and
the serial number are listed.

• ETERNUS DX900 S5

14 Configuration Guide (Basic)


Preface

Drive Enclosures
• 2.5"/3.5" type drive enclosure

• High-density drive enclosure

15 Configuration Guide (Basic)


Preface

Power Distribution Unit

Manufacturer's label
The model name and the serial number are listed.

16 Configuration Guide (Basic)


1. Configuration Workflow
This chapter describes the flow of work from the installation of the ETERNUS DX60 S5/DX100 S5/DX200 S5 in a
rack to the completion of the configuration and the flow of work from turning on the ETERNUS DX500 S5/DX600
S5/DX900 S5 to the completion of the configuration.

ETERNUS DX60 S5/DX100 S5/DX200 S5


■ From Rack Installation to Completion of the Initial Setup
For details about the ETERNUS Web GUI operations affixed with the ( ) icon, refer to the FUJITSU Storage
ETERNUS video site in addition to this manual. (See the "Configuration Guide (Basic)" section in https://
www.fujitsu.com/global/products/computing/storage/eternus/video-library/afdx/index.html.)
When using power synchronization, perform the procedure described in "Power Synchronized Unit Connection"
(page 58).

ETERNUS DX Administration terminal for setup

Install in a rack Prepare the administration terminal for setup


u "3.Rack Installation" u "Preparing the Administration Terminal for Setup"

Attach network information labels


u "LAN Connection Preparation
for Operation Management"

Connect to the host


u "Host Interface Cable Connection"

Connect the drive enclosures Connect the administration terminal for setup
u "Drive Enclosure Connection" u "Administration Terminal Connection"

Connect the power cord


u "Power Cord Connection"

Turn on the ETERNUS DX


u "Powering On"

Start ETERNUS Web GUI


u "ETERNUS Web GUI Startup"

Perform the initial setup


u "Storage Management (Initial Setup 1)"

Operation management terminal

Connect LAN cables


u "LAN Cable Connection(for Operation Management)"

: Required
: Optional Completion of the initial setup
: ETERNUS Web GUI operation

17 Configuration Guide (Basic)


1. Configuration Workflow
ETERNUS DX60 S5/DX100 S5/DX200 S5

■ From Completion of the Initial Setup to Completion of the Configuration (When Using the
Smart Setup Wizard)

Completion of the initial setup

ETERNUS DX Host (server)

Set the firewall Prepare the server for connection


u "Firewall Settings" u "Server Connection Preparation"

Set the date, SNMP and Syslog


u "Initial Setup 2 (Optional)"

Set the ETERNUS DX for connection


u "Smart Setup Wizard"

Configure the monitoring settings


u "8. Monitoring Settings"

Configure the power control settings


u "9. Power Control Setup"

Check the system status


u "10. System Status Check"

Completion of the configuration

: Required
: Optional
: ETERNUS Web GUI operation

18 Configuration Guide (Basic)


1. Configuration Workflow
ETERNUS DX60 S5/DX100 S5/DX200 S5

■ From Completion of the Initial Setup to Completion of the Configuration (without Using the
Smart Setup Wizard)
For details about the ETERNUS Web GUI operations affixed with the ( ) icon, refer to the FUJITSU Storage
ETERNUS video site in addition to this manual. (See the "Configuration Guide (Basic)" section in https://
www.fujitsu.com/global/products/computing/storage/eternus/video-library/afdx/index.html.)

Completion of the initial setup

ETERNUS DX Host (server)

Set the firewall Prepare the server for connection


u "Firewall Settings" u "Server Connection Preparation"

Set the date, SNMP and Syslog


u "Initial Setup 2 (Optional)"

Set a RAID configuration


u "Configuration Settings for
RAID Groups or Thin Provisioning"

Set the ETERNUS DX for connection


u "7. Host Interface Management"

Configure the monitoring settings


u "8. Monitoring Settings"

Configure the power control settings


u "9. Power Control Setup"

Check the system status


u "10. System Status Check"

Completion of the configuration

: Required
: Optional
: ETERNUS Web GUI operation

19 Configuration Guide (Basic)


1. Configuration Workflow
ETERNUS DX500 S5/DX600 S5/DX900 S5

ETERNUS DX500 S5/DX600 S5/DX900 S5


■ From Turning On the Power to Completion of the Initial Setup
For details about the ETERNUS Web GUI operations affixed with the ( ) icon, refer to the FUJITSU Storage
ETERNUS video site in addition to this manual. (See the "Configuration Guide (Basic)" section in https://
www.fujitsu.com/global/products/computing/storage/eternus/video-library/afdx/index.html.)
When using power synchronization, perform the procedure described in "Power Synchronized Unit Connection"
(page 58).

ETERNUS DX Administration terminal

Turn on the ETERNUS DX Prepare the administration terminal


u "Preparation and Setup for
u "Powering On" the Administration Terminal"

Start ETERNUS Web GUI


u "ETERNUS Web GUI Startup"

Perform the initial setup


u "Storage Management (Initial Setup 1)"

Operation management terminal

Connect LAN cables


u "LAN Cable Connection(for Operation Management)"

: Required
: Optional Completion of the initial setup
: ETERNUS Web GUI operation

20 Configuration Guide (Basic)


1. Configuration Workflow
ETERNUS DX500 S5/DX600 S5/DX900 S5

■ From Completion of the Initial Setup to Completion of the Configuration (When Using the
Smart Setup Wizard)

Completion of the initial setup

ETERNUS DX Host (server)

Set the firewall Prepare the server for connection


u "Firewall Settings" u "Server Connection Preparation"

Set the date, SNMP and Syslog


u "Initial Setup 2 (Optional)"

Set the ETERNUS DX for connection


u "Smart Setup Wizard"

Configure the monitoring settings


u "8. Monitoring Settings"

Configure the power control settings


u "9. Power Control Setup"

Check the system status


u "10. System Status Check"

Completion of the configuration

: Required
: Optional
: ETERNUS Web GUI operation

21 Configuration Guide (Basic)


1. Configuration Workflow
ETERNUS DX500 S5/DX600 S5/DX900 S5

■ From Completion of the Initial Setup to Completion of the Configuration (without Using the
Smart Setup Wizard)
For details about the ETERNUS Web GUI operations affixed with the ( ) icon, refer to the FUJITSU Storage
ETERNUS video site in addition to this manual. (See the "Configuration Guide (Basic)" section in https://
www.fujitsu.com/global/products/computing/storage/eternus/video-library/afdx/index.html.)

Completion of the initial setup

ETERNUS DX Host (server)

Set the firewall Prepare the server for connection


u "Firewall Settings" u "Server Connection Preparation"

Set the date, SNMP and Syslog


u "Initial Setup 2 (Optional)"

Set a RAID configuration


u "Configuration Settings for
RAID Groups or Thin Provisioning"

Set the ETERNUS DX for connection


u "Connection Settings for
the ETERNUS DX"

Configure the monitoring settings


u "8. Monitoring Settings"

Configure the power control settings


u "9. Power Control Setup"

Check the system status


u "10. System Status Check"

Completion of the configuration

: Required
: Optional
: ETERNUS Web GUI operation

22 Configuration Guide (Basic)


2. Preparation
This chapter explains the preparations necessary for configuring a system using the ETERNUS DX.

System Configuration Example


The example in this section is described by assuming that the system in Figure 1 is being configured.

■ Configuration Diagram

Figure 1 System Configuration Example

A Administration B E-mail server B SNMP server B Syslog server


terminal

LAN for operation


management

C
FC connection
B Remote support
iSCSI connection
Multipath connection center

D Host server D ETERNUS DX

Symbol Setting Refer to:

A Administration terminal setup "Preparation and Setup for the Administration Terminal"
(page 24)

B Event notification setting "8. Monitoring Settings" (page 159)

C FC connection, iSCSI connection, and multipath connection "Server Connection Preparation" (page 24)

D SAN environment configuration "6. Configuration Settings for RAID Groups or Thin
Provisioning" (page 108)
"7. Host Interface Management" (page 133)

■ Server (Host) Environment

Table 1 Server (Host) Environment


Item Explanation

Server OS Solaris, Linux, Windows, or VMware

Connection Configuration FC connection or iSCSI connection, duplicated with multipath connection

Multipath Driver ETERNUS Multipath Driver

To connect the server and the ETERNUS DX via a switch, setting up of the switch must be performed. For details
on this setting, refer to relevant manuals of the switch.

23 Configuration Guide (Basic)


2. Preparation
Server Connection Preparation

Server Connection Preparation


Prepare the server to connect to the ETERNUS DX.
A host bus adapter (HBA) that matches the connection interface that is to be used and a driver for the HBA are
required. Some types of HBA require utility software. Prepare the required environment for the HBA that is to be
used by referring to the HBA manual.
To connect the server and the ETERNUS DX via a switch, setting up of the switch must be performed.
For details on this setting, refer to relevant manuals of the switch.

■ Server Connection Setup


Confirm that the work in "■ From Rack Installation to Completion of the Initial Setup" (page 17) or "■ From
Turning On the Power to Completion of the Initial Setup" (page 20) is completed.
Connect the host interface cards of the ETERNUS DX with the Host Bus Adapters (HBAs) of the server using the
host interface cables.
The IP address to connect to the iSCSI network must be set on the server before the ETERNUS DX is connected.
After the server connection setup is completed, confirm that the volumes in the ETERNUS DX can be recognized
by the server.

■ Reference Documents
Refer to "Configuration Guide -Server Connection-".
https://www.fujitsu.com/global/support/products/computing/storage/manuals-list.html
• Select product category: Hybrid Storage Systems
• Selected document kind: Configuration Guide -Server Connection-
• Selected interface: relevant interface
• Selected OS: relevant OS

Preparation and Setup for the Administration Terminal


The operation and management of the ETERNUS DX are performed by using a Web browser on the
administration terminal that is connected to the LAN for operation management (MNT port).
Prepare and set up the administration terminal in advance.

■ Administration Terminal Preparation


Prepare the administration terminal that contains the following environment:
• Web browser
The usable Web browsers are shown below. Using Web browsers other than the following is possible, but
proper operation is not guaranteed.
- Microsoft Internet Explorer 10.0 (desktop version), 11.0 (desktop version)
- Mozilla Firefox ESR 68, 78
- Google Chrome 75 to 84

24 Configuration Guide (Basic)


2. Preparation
LAN Connection Preparation for Operation Management

■ Administration Terminal Setup


Check the settings of the Web browser on the administration terminal.

1 Set the IP address and subnet mask of the administration terminal. Set the following values.
IP address: 192.168.1.2
Subnet mask: 255.255.255.0

2 Check the settings of the Web browser.


For details on the required settings, refer to "Configuration Guide (Web GUI)".

LAN Connection Preparation for Operation Management


Completing and Attaching the Network Setting Label

Enter the network setting information on the Network Setting label. Attach the Network Setting label on the
rack wall near the controller enclosure to avoid losing it.

Figure 2 Network Setting Label

Network Setting
IP address of MNT port :
IP address of FST port : . . .
Subnet Mask of FST port : . . .
IP address of RMT port :

Complete the following items in the Network Setting label.


• IP address of MNT port
Enter the IP address for the MNT port of the ETERNUS DX. The MNT port is a LAN port that is used to perform
operation management connection.
• IP address of FST port
This item is not used. No information needs to be entered for this item.
• Subnet Mask of FST port
This item is not used. No information needs to be entered for this item.
• IP address of RMT port
Enter the IP address for the RMT port of the ETERNUS DX. The RMT port is a LAN port that is used during initial
setup and to connect to the remote support center.

25 Configuration Guide (Basic)


2. Preparation
LAN Connection Preparation for Operation Management

LAN Related Specifications

■ Network Communication Protocols


The usable LAN ports and functions are different depending on the usage and protocol.
The following table shows how the LAN ports may be used (by usage and protocol).

Table 2 LAN Port Availability

Port Master CM Slave CM


Usage Protocol tcp / udp Direction Remarks
number MNT RMT MNT RMT

ETERNUS Web GUI http / tcp 80 / 443 from ¡ ¡ △ (*1) △ (*1) Accessed
https from a
Web
browser

ETERNUS CLI telnet / tcp 23 / 22 from ¡ ¡ △ (*1) △ (*1) −


ssh

ftp (client) tcp 21 to ¡ ¡ △ (*1) △ (*1) −

SNMP agent snmp udp 161 from ¡ ¡ ¡ ¡ −

trap snmp trap udp 162 (*2) to ¡ (*3) ¡ (*3) ´ ´ −

SMI-S http / tcp 5988 / from ¡ ´ ´ ´ Used for


https 5989 SMI-S
client
communic
ation

http / tcp − to ¡ ´ ´ ´ Used for


https event
communic
ations
with the
SMI-S
listener,
etc.

SLP udp 427 to ¡ ´ ´ ´ Used for

SLP tcp 5993 from ¡ ´ ´ ´ service


inquiry
communic
ation from
the SMI-S
client

RESTful API https tcp 5665 from ¡ ¡ ´ ´ −

E-mail smtp tcp 25 (*2) to ¡ (*3) ¡ (*3) ´ ´ Used for


(client) failure
notificatio
n, etc.

NTP NTP udp 123 to ¡ (*3) ¡ (*3) ´ ´ −


(client)

26 Configuration Guide (Basic)


2. Preparation
LAN Connection Preparation for Operation Management

Port Master CM Slave CM


Usage Protocol tcp / udp Direction Remarks
number MNT RMT MNT RMT

REMCS smtp tcp 25 (*2) to ¡ (*3) ¡ (*3) ´ ´ Used for


(remote support) (client) failure
notificatio
n, etc.

pop3 tcp 110 (*2) to ¡ (*3) ¡ (*3) ´ ´ Used for


(client) SMTP
authentica
tion

http tcp 80 or 8080 to ¡ (*3) ¡ (*3) ´ ´ Used for


(client) (*2) firmware
download,
etc.

AIS Connect (remote https tcp 443 to ¡ (*3) ¡ (*3) ´ ´ —


support) (client)

Syslog Syslog udp 514 (*2) to ¡ (*3) ¡ (*3) ´ ´ −


(event notification and
audit log sending)

RADIUS Radius udp 1812 (*2) to ¡ (*3) ¡ (*3) ´ ´ −

ping ICMP − − from ¡ (*3) ¡ (*3) ´ ´ −

KMIP (key SSL tcp 5696 (*2) to ¡ (*3) ¡ (*3) ´ ´ −


management)

ECD (*4) Unique udp 9686 from ¡ ´ ´ ´ −


protocol

¡: Possible / △: Partially possible / ´: Not possible


*1: Only the following functions are available:

• Checking the ETERNUS DX status


• Switching the Master CM
*2: Modifiable
*3: May use either the MNT port or RMT port.
*4: Used with the Remote Installation function. ETERNUS Connection Detecting tool (ECD) is a Windows application for collecting the
network setting information of the ETERNUS DX.
For details on the port numbers for the ETERNUS SF Software, refer to the manual of each Storage Foundation
Software ETERNUS SF.

■ Communication Modes
The default LAN operation mode is "Auto Negotiation" which allows the ETERNUS DX to automatically recognize
1000BASE-T/100BASE-TX/10BASE-T and Full/Half-Duplex connections. However, some devices may require that a
fixed communication mode be set.

27 Configuration Guide (Basic)


3. Rack Installation

This chapter describes the procedure for installing the ETERNUS DX in a rack.
Make sure to check "Safety Notes and Regulations" before starting the installation. Also refer to the rack manual.

• Wear a wrist strap or touch a metal part to discharge the human body's natural
static electricity before starting each operation. Failure to discharge static
electricity may cause failure in the ETERNUS DX.
• If components are installed in a way other than as described in this chapter,
damage and/or device failure or electrical shock may occur.
• Do not install the power distribution unit in the rack with cables, such as power
cords, connected.
• The ETERNUS DX contains delicate components, and should be handled gently. Do
not drop or knock the ETERNUS DX against the rack when installing it. Also, do not
knock the other devices installed in the rack.
• The center of gravity must be taken into consideration to prevent a rack from
toppling over. Enclosures should generally be installed from bottom to top to
lower the center of gravity and to ensure the safe use of racks.

• Do not uninstall the drives that are installed by default or move them to any other
slot.
Contact your sales representative or maintenance engineer if drives that are
installed by default need to be uninstalled or moved to another slot.

28 Configuration Guide (Basic)


3. Rack Installation

Note
• If the ETERNUS DX is installed at the bottom of a rack, a space for the surplus of cables may not be
available in some racks, preventing the ETERNUS DX from being pulled out when maintenance work is
required. In this case, secure a space of 1U or more at the bottom when installing the storage system.
• To install an enclosure, power distribution units, power synchronized units, and UPS units in a single
rack, mount the devices in the following order (from bottom to top).

Rack

2.5"/3.5" type
5
drive enclosure

High-density
4 drive enclosure

Controller
3
enclosure

Power distribution unit/


2
Power synchronized unit

1 UPS

Installation
order

29 Configuration Guide (Basic)


3. Rack Installation
Power Distribution Unit Installation

Power Distribution Unit Installation


This section describes how to install a power distribution unit in a rack.

• Do not connect any devices other than the ETERNUS DX to the power distribution
unit.

Installing Power Distribution Unit (1U)


This section describes how to install a 1U power distribution unit in a rack.

1 Attach the M6 cage nuts to the rear rack pillar.


• Attachment positions

On either side, insert four M6 cage nuts in the 1st and 3rd holes above the power distribution unit base
line.
(Rack pillar: rear)
[Left] [Right]
M6 cage nut M6 cage nut

3rd hole 3rd hole


1U Power distribution unit
1st hole 1st hole
Power distribution unit
base line

• Attachment procedure

Clip the M6 cage nut tabs into the desired hole from the inside.

Side view
M6 cage nut

Rack pillar (square hole)

2 Attach the cable holders to the power distribution unit.


Use four M3 screws to attach the cable holders.

30 Configuration Guide (Basic)


3. Rack Installation
Power Distribution Unit Installation

Cable holder

M3 screw

M3 screw

M3 screw

3 Install the power distribution unit in the rack.

Use four M6 screws to fasten it in the rack pillar.

(Rack pillar: rear)

M6 screw

M6 screw

4 Attach the blank panel to the front side of the rack.

The blank panel should be attached at the same height as the power distribution unit.
Blank panel

Power distribution unit (Rack pillar: front)

(Rack pillar: rear)

31 Configuration Guide (Basic)


3. Rack Installation
Power Distribution Unit Installation

Installing Power Distribution Unit (2U)


This section describes how to install a 2U power distribution unit in a rack.

1 Attach the M5 cage nuts to the rear rack pillar.


• Attachment positions

On either side, insert eight M5 cage nuts in the 1st, 3rd, 4th, and 6th holes above the power
distribution unit base line.
M5 cage nut (Rack pillar: rear) M5 cage nut
[Left] [Right]
6th hole 6th hole
4th hole 2U 1U Power distribution unit 4th hole

1U Power distribution unit


3rd hole 3rd hole
1st hole 1st hole
Power distribution unit
base line

• Attachment procedure

Clip the M5 cage nut tabs into the desired hole from the inside.

Side view
M5 cage nut

Rack pillar (square hole)

2 Attach the cable holders to the power distribution unit.


Use eight M3 screws to attach the cable holders.

Cable holder

M3 screw

M3 screw

32 Configuration Guide (Basic)


3. Rack Installation
Power Distribution Unit Installation

3 Install the power distribution unit in the rack.

Fasten it to the prepared holes in the pillars with eight M5 screws.

(Rack pillar: rear)

M5 screw

M5 screw

4 Attach the blank panel to the rack front.

The blank panel should be attached at the same height as the power distribution unit.

Blank panel

Power distribution unit


(Rack pillar: front)

(Rack pillar: rear)

33 Configuration Guide (Basic)


3. Rack Installation
Controller Enclosure Installation

Controller Enclosure Installation


This section describes how to install a controller enclosure in a rack.

1 Adjust the sizes of the rack rail (for left side) and the rack rail (for right side) to fit the rack.

Loosen the M4 screws to adjust the length of the rack rails to match the distance between the front and
rear rack pillars. Leave the M4 screws slightly unscrewed, as the rack rails must be attached to the rack
before they can be completely tightened.
Loosen the M4 screws to
adjust the length of the
rack rails to match the
distance between the
front and rear rack pillars.

(Rack pillar: rear)

Rack rail (left)


An "L" mark is on the
inner side.
[Left]

(Rack pillar: front)


Rack rail (right)
An "R" mark is on the inner side.

[Right]

2 Attach the rack rails to the rack.


Use the two plates to fasten the rack rails to the front rack pillars. Use the washers to fasten the rack rails
to the rear rack pillars.

Note
Make sure to attach the rack rails to rack pillars so that they fit exactly together without any space
between them.

M5 screw
Rack rail (left)
Washer

(Rack pillar: rear)


Plate
M5 screw
M5 screw Washer

Plate

M5 screw
(Rack pillar: front)
Rack rail (right)

34 Configuration Guide (Basic)


3. Rack Installation
Controller Enclosure Installation

The M5 screw positions for the rack rails are determined by the controller enclosure base line.
Insert the M5 screws in the 1st and 6th holes on the front rack pillars above the base line and in the 2nd
and 5th holes on the rear rack pillars above the base line to fasten the rack rails.
Controller enclosure: front
6th hole [Left] [Right]
(M5 screw) 6th hole
(M5 screw)
2U
1st hole 1st hole
(M5 screw) Controller (M5 screw)
enclosure base line

Rack rail

Controller enclosure: rear


5th hole [Left] [Right]
(M5 screw) 5th hole
(M5 screw)
2U
2nd hole 2nd hole
(M5 screw) (M5 screw)
Controller
enclosure base line

Rack rail

3 Tighten the M4 screws of the rack rails that were slightly unscrewed in Step 1.

4 Install the controller enclosure in the rack.

• When installing or removing the controller enclosure to or from the rack,


make sure that the sides and the bottom of the controller enclosure are
held by two or more people. Failure to do so may cause injury.

5 Fasten the controller enclosure in the rack.


Use three M5 screws to fasten it in the rack pillar.

35 Configuration Guide (Basic)


3. Rack Installation
Controller Enclosure Installation

M5 screw

M5 screws

6 Attach the flange cover.

36 Configuration Guide (Basic)


3. Rack Installation
Drive Enclosure Installation

Drive Enclosure Installation


This section explains how to install a 2.5"/3.5" type drive enclosure in a rack.

IMPORTANT
Drive enclosures must be installed above the controller enclosure. When installing multiple drive
enclosures, install them in the order of the "DE_No. label" numbers that are attached to the drive
enclosures. The DE_No. labels are attached on the following locations.

Right end of the drive enclosure Top right of the drive enclosure
as seen from the front as seen from the rear

DE_No. label

1 Adjust the sizes of the rack rail (for left side) and the rack rail (for right side) to fit the rack.
Loosen the M4 screws to adjust the length of the rack rails to match the distance between the front and
rear rack pillars. Leave the M4 screws slightly unscrewed, as the rack rails must be attached to the rack
before they can be completely tightened.

Loosen the M4 screws to


adjust the length of the
rack rails to match the
distance between the
front and rear rack pillars.

(Rack pillar: rear)

Rack rail (left)


An "L" mark is on the
inner side.
[Left]

(Rack pillar: front)


Rack rail (right)
An "R" mark is on the inner side.

[Right]

2 Attach the rack rails to the rack.


Use the two plates to fasten the rack rails to the front rack pillars. Use the washers to fasten the rack rails
to the rear rack pillars.

37 Configuration Guide (Basic)


3. Rack Installation
Drive Enclosure Installation

Note
Make sure to attach the rack rails to rack pillars so that they fit exactly together without any space
between them.

M5 screw
Rack rail (left)
Washer

(Rack pillar: rear)


Plate
M5 screw
M5 screw Washer

Plate

M5 screw
(Rack pillar: front)
Rack rail (right)

The M5 screw positions for the rack rails are determined by the drive enclosure base line.
Insert the M5 screws in the 1st and 6th holes on the front rack pillars above the base line and in the 2nd
and 5th holes on the rear rack pillars above the base line to fasten the rack rails.
Front view of drive enclosure
[Left] [Right]
Sixth screw Sixth screw
(M5 screw) (M5 screw)

2U
First screw First screw
(M5 screw) (M5 screw)
Bottom position of
drive enclosure

Rack rail

Rear view of drive enclosure


[Left] [Right]
Fifth screw Fifth screw
(M5 screw) (M5 screw)
2U
Second screw Second screw
(M5 screw) (M5 screw)
Bottom position of
drive enclosure
Rack rail

3 Tighten the M4 screws of the rack rails that were slightly unscrewed in Step 1.

4 Install the drive enclosure in the rack.

• When installing or removing the drive enclosure to or from the rack, make
sure that the sides and the bottom of the drive enclosure are held by two or
more people. Failure to do so may cause injury.

38 Configuration Guide (Basic)


3. Rack Installation
Drive Enclosure Installation

5 Fasten the drive enclosure in the rack.


Use four M5 screws to fasten it in the rack pillar.

M5 screws

M5 screws

6 Attach the flange cover.

39 Configuration Guide (Basic)


3. Rack Installation
High-Density Drive Enclosure Installation

High-Density Drive Enclosure Installation


This section describes how to install a high-density drive enclosure in a rack.

IMPORTANT
High-density drive enclosures must be installed above the controller enclosure. When installing multiple
high-density drive enclosures, install them in the order of the "DE_No. label" numbers that are attached to
the high-density drive enclosures. The DE_No. labels are attached on the following locations.

Right front side of the high-density drive enclosure Upper right rear side of the high-density drive enclosure

DE_No. label

1 Adjust the sizes of the rack rail (for left side) and the rack rail (for right side) to fit the rack.
Pull the rail lock lever in the direction of the arrow and unlock it to adjust the length of the rack rails to
match the distance between the front and the rear rack pillars. Leave the rail lock lever unlocked because
the rail lock lever is locked after the rack rail is installed.

Rail lock lever


Unlock the levers to adjust the length of the
rack rails to match the distance between the
front and rear rack pillars.

[Left]
Rack rail (left)
"Left" is on the exterior

[Right]
Rack rail (right)
"Right" is on the exterior

(Rack pillar: front)


(Rack pillar: rear)

40 Configuration Guide (Basic)


3. Rack Installation
High-Density Drive Enclosure Installation

2 Attach the rack rails to the rack.


(1) Insert the rack rails into the holes of the front and the rear rack pillars to lock the rail lock lever.

[Left]

[Right]

(Rack pillar: front) (Rack pillar: rear)

Rail lock lever

(2) Use the M4 screws to fasten the front and the rear rack rails.
Use the washers to fasten the rack rails to the front and rear rack pillars.

Note
Make sure to attach the rack rails to rack pillars so that they fit exactly together without any
space between them.

Washer

M4 screw

Rack rail Washer


(left) M4 screw
(Rack pillar: rear)

Washer

M4 screw

Washer
Rack rail
M4 screw (right)

(Rack pillar: front)

The M4 screw positions for the rack rails are determined by the high-density drive enclosure base
line.
Insert the M4 screws in the second holes on the front and rear rack pillars above the base line to
fasten the rack rails.

41 Configuration Guide (Basic)


3. Rack Installation
High-Density Drive Enclosure Installation

High-density drive enclosure


Front/Rear
[Left] [Right]

4U

2nd hole 2nd hole


(M4 screw) (M4 screw)
High-density drive
enclosure base line

Rack rail

3 Install the stopper bracket (for left side) and the stopper bracket (for right side).
Attach the stopper bracket to the front rack pillar.

Rack rail
(left)
Stopper bracket
(left)
(Rack pillar: rear)
M5 screw

M5 screw
Rack rail
(right)

Stopper bracket
(Rack pillar: front) (right)

The M5 screw positions for the stopper brackets are determined by the high-density drive enclosure base
line.
Insert the M5 screws in the seventh holes above the base line to fasten the stopper brackets.

High-density drive enclosure


Front
[Left] [Right]

7th hole 4U 7th hole


(M5 screw) (M5 screw)

High-density drive
enclosure base line

Rack rail

4 Install the flap brackets.


Attach flap bracket A and B on the right side of the rear rack pillar with the M4 screws.

42 Configuration Guide (Basic)


3. Rack Installation
High-Density Drive Enclosure Installation

Rack rail
(right)

(Rack pillar: front)

Stopper bracket B

M4 screw Rack rail


(left)

Stopper bracket A
(Rack pillar: rear)

The M4 screw positions for flap bracket A and B are determined by the high-density drive enclosure base
line.
Insert the M4 screws in the seventh and eighth holes above the base line to fasten the flap brackets.

Rear view of a high-density drive enclosure

[Left] [Right]
Flap bracket B

7th & 8th


4U holes
(M5 screws)

High-density drive
enclosure base line

Rack rails

5 Install the high-density drive enclosure in the rack.

• For safety and stability, use a lifter to install or remove high-density drive
enclosures in the rack.

6 Fasten the high-density drive enclosure in the rack.


Use four M5 screws to fasten it in the rack pillar.

43 Configuration Guide (Basic)


3. Rack Installation
High-Density Drive Enclosure Installation

(Rack pillar: rear)

M5 screws

(Rack pillar: front) M5 screws

7 Attach the cable management arm.


To attach the cable management arm, place the arm in the bracket on the rear of the high-density drive
enclosure. After placing the arm in the bracket, firmly attach the arm with the pin.

Pin

Cable management arm

44 Configuration Guide (Basic)


3. Rack Installation
High-Density Drive Enclosure Installation

8 Attach the front cover.

Front cover

45 Configuration Guide (Basic)


4. Connecting Cables
This chapter explains how to connect various cables to the ETERNUS DX.

• Wear a wrist strap or touch a metal part to discharge the human body's natural
static electricity before starting each operation. Failure to discharge static
electricity may cause failure in the ETERNUS DX.

Host Interface Cable Connection

Connect the ETERNUS DX to the connection destination using host interface cables. The connection procedure
varies depending on the type of host interface that is used for the ETERNUS DX.
If the host interface in the ETERNUS DX100 S5/DX200 S5 is iSCSI 10Gbit/s (10GBASE-SR), and an FC cable is used
for the connection, the SFP+ module must be installed in the host interface port before the cable is connected.
Prepare the same number of host interface cables as the number of host interface ports.

IMPORTANT
• To help with host interface cable management and prevent incorrect connections, attach labels to the
cables that show which end is for the connection origin and which end is for the connection destination.
• SAS 12Gbit/s host interface cables have the same connector type as the mini SAS HD cables between
enclosures. To prevent accidental connections to a DI port on the drive enclosure or the controller
enclosure with the host interface cable, check the connection destination port.
In addition, the cable connector of the host interface is plugged in an orientation that is different from
the connector of the mini SAS HD cables between enclosures. When connecting the host interface cable,
make sure that the tab is facing up.
• When connecting a host interface cable, check the direction of the connector tab and insert it all the
way in firmly.
When disconnecting a host interface cable, pull out the connector while holding its tab.
• If the host interface ports and host interface cable connectors have covers, remove the covers. Keep the
removed covers in a safe place where they will not be lost.
• When connecting the cables, position them so that they will not obstruct replacement of the power
supply unit or controllers by the maintenance engineer.

Note
This section uses a controller enclosure with two controllers as an example to explain the connection
procedure. When one controller is installed, this procedure is only applied to Controller 0 (CM#0).

46 Configuration Guide (Basic)


4. Connecting Cables
Host Interface Cable Connection

SFP+ Module Handling Instructions


The following shows instructions for handling an SFP+ module.

● About Condensation

• When moving an SFP+ module from a cold place, such as an unconditioned


store house in winter, to a warmer place such as an air-conditioned room, the
severe temperature change may result in condensation forming.
To avoid this, allow the packed SFP+ modules sufficient time in the warmer
place (one hour for each 15°C of temperature difference) to adapt to the new
temperature.

● About Static Electricity

• When handling SFP+ modules, wear a wrist strap or touch a metal part to
discharge the human body's natural static electricity. Failure to discharge
static electricity may cause failure in the ETERNUS DX.
• Leave the SFP+ module in its package until ready to install it.

● About Shock

• Do not handle the SFP+ module roughly or subject it to physical shocks when
laying it down.
• Do not place any objects on top of SFP+ modules.
• Do not knock or drop the SFP+ module on hard objects.

This section uses an iSCSI 10Gbit/s host interface (CA) as an example to show the connection procedure.

1 Install an SFP+ module in the host interface port.


This procedure is required only when an SFP+ module must be installed.

Note
Step 1 is not required if the host interface (CA) is iSCSI 10Gbit/s (10GBASE-T).

47 Configuration Guide (Basic)


4. Connecting Cables
Host Interface Cable Connection

(1) Remove the connector cover attached to the port of the SFP+ module and open the lever.

SFP+ module

Lever

IMPORTANT
Keep the removed connector cover in a safe place where it will not be lost.

(2) Check the direction of the SFP+ module and insert it all the way into the port cage of the host
interface.
Install the SFP+ module in Port#0 first, and then Port#1.

Figure 3 ETERNUS DX100 S5/DX200 S5 Rear View of a Controller (Reference)


Host interface Host interface Host interface Host interface
(CA#0) (CA#1) (CA#0) (CA#1)
Controller 0 Controller 1
(CM#0) (CM#1)

Port#0 Port#1 Port#0 Port#1 Port#0 Port#1 Port#0 Port#1

SFP+ module (Insertion direction)

Topside

(3) Close the SFP+ module's lever.

2 Connect a host interface cable to the ETERNUS DX.

Insert the host interface cable connectors in the host interface ports (iSCSI) of Controller 0 (CM#0) and
Controller 1 (CM#1).

48 Configuration Guide (Basic)


4. Connecting Cables
Host Interface Cable Connection

• When connecting the host interface cables, position them so that they will
not obstruct replacement of the power supply unit or controllers by the
maintenance engineer.

3 Connect the host interface cable to the connection destination.


Connect the other end of the cable to the connection destination.

49 Configuration Guide (Basic)


4. Connecting Cables
Drive Enclosure Connection

Drive Enclosure Connection

When a drive enclosure is installed, connect the drive enclosure to the controller enclosure with a mini SAS HD
cable between enclosures. When multiple drive enclosures are installed, connect the drive enclosures with mini
SAS HD cables between enclosures.
0.75m mini SAS HD cables between enclosures are provided with 2.5" type drive enclosures and 3.5" type drive
enclosures. 2.5m cables between enclosures are provided with high-density drive enclosures.
The connection type between Controller 0 and the I/O modules for Controller 0 is different from that between
Controller 1 and the I/O modules for Controller 1.
Between Controller 0 and I/O module line 0, connect the source DI (OUT) port and the destination DI (IN) port in
ascending order of the drive enclosure numbers (DE-ID) of the drive enclosure.
Between Controller 1 and I/O module line 1, contrary to the line 0, connect the source DI (OUT) port and the
destination DI (IN) port in descending order of the drive enclosure numbers (DE-ID) of the drive enclosure.
Do not connect anything to the last DI port that is nearest to the edge.
The last ports nearest to the edge are the DI (OUT) port of I/O module 0 in the drive enclosure of the largest DE-
ID and the DI (OUT) port of I/O module 1 in the drive enclosure of the smallest DE-ID.
The connection configurations of cables between enclosures and the last DI port location when two drive
enclosures are installed are shown below.

Figure 4 Connecting Cables between Enclosures (When Only One Controller Is Installed)

The last
DI port

DI (IN) DI (OUT)
I/O module 0
Drive
(IOM#0)
enclosure 2

DI (IN) DI (OUT)
I/O module 0
(IOM#0)
Drive
enclosure 1

DI (OUT)
Controller 0
(CM#0)
Controller
enclosure

Connection configuration between


Controller 0 and the I/O module line 0

50 Configuration Guide (Basic)


4. Connecting Cables
Drive Enclosure Connection

Figure 5 Connecting Cables between Enclosures (When Two Controllers Are Installed)

The last
DI port

DI (IN) DI (OUT) DI (IN) DI (OUT)


Drive I/O module 0 I/O module 1
enclosure 2 (IOM#0) (IOM#1)

The last
DI port

DI (IN) DI (OUT) DI (IN) DI (OUT)


I/O module 0 I/O module 1
Drive (IOM#0) (IOM#1)
enclosure 1

DI (OUT) DI (OUT)
Controller 0 Controller 1
Controller (CM#0) (CM#1)
enclosure

Connection configuration between Connection configuration between


Controller 0 and the I/O module line 0 Controller 1 and the I/O module line 1

IMPORTANT
• To help with management of the mini SAS HD cable between enclosures and prevent incorrect
connections, make sure to attach the destination labels to the connectors of the cables.
• When connecting the mini SAS HD cable between enclosures, check the direction of the connector (the
tab must be pointed downward) and firmly insert all the way in.
To disconnect the mini SAS HD cables between enclosures, hold the tab and then pull out the connector.

Tab

51 Configuration Guide (Basic)


4. Connecting Cables
Drive Enclosure Connection

Note
When high-density drive enclosures are installed, fasten the high-density drive enclosure cable between
enclosures with the clamp belts to the flap brackets and the cable management arm on the rear of the
device.

Clamp belts

Flap bracket

Clamp belts
Cable management arm

The following procedure explains how to connect the mini SAS HD cable between enclosures.

1 Attach the destination labels to the connectors of the mini SAS HD cables between enclosures.
(1) Before attaching the destination labels, check the connection destination of the mini SAS HD cables
between enclosures.
• The connector on which the "n" symbol is printed is connected to the DI (OUT) port on the
controller enclosure or the drive enclosure.

• The connectors on the cable with the "l" symbol are connected to the DI (IN) ports on the drive
enclosure.

52 Configuration Guide (Basic)


4. Connecting Cables
Drive Enclosure Connection

The following figures show the connection of the mini SAS HD cable between enclosures connecting
the controller enclosure to drive enclosure 1 and connecting drive enclosure 1 to drive enclosure 2.
• When only one controller is installed

Drive enclosure 2

Drive enclosure 1

Controller enclosure

• When two controllers are installed

Drive enclosure 2

Drive enclosure 1

Controller enclosure

(2) Attach the destination labels to the connectors of the mini SAS HD cables between enclosures.
"Controller number" or "Drive enclosure number - IOM number" is printed on the destination labels
in the "Connection origin DI port g Connection destination DI port" format. The "n" or "l" symbol is
also printed on the destination labels.
Carefully check the connection origin and connection destination, and then attach the destination
labels.

Drive enclosure number


IOM (I/O module) number

DE01 0
CM (controller) number

CM0 0

53 Configuration Guide (Basic)


4. Connecting Cables
Drive Enclosure Connection

The following figure shows an example of the destination label attachments on the mini SAS HD
cables between enclosures that connect the controller enclosure to drive enclosure 1 and that
connect drive enclosure 1 to drive enclosure 2.

'(

'( '(
&0
'(
Drive enclosure 2
'( '(

'( '(
'(
'(
Drive enclosure 1 &0

'(

&0
Controller enclosure

2 Connect the controller enclosure to the drive enclosure and connect between the drive enclosures.
Connect Controller 0 first.
(1) Connect the controller enclosure to the drive enclosure.
Connect the DI (OUT) port of Controller 0 (CM#0) in the controller enclosure to the DI (IN) port of I/O
module 0 (IOM#0) in drive enclosure 1 with the mini SAS HD cable between enclosures.
(i) Connect the plug to be connected to DI (OUT) port, to the DI (OUT) port of the Controller 0
(CM#0).
(ii) Connect the plug to be connected to DI (IN) port, to the DI (IN) port of the I/O module 0
(IOM#0).

Drive enclosure 1

Controller enclosure

(2) Connect between the drive enclosures.


Connect the DI (OUT) port of I/O module 0 (IOM#0) in drive enclosure 1 to the DI (IN) port of I/O
module 0 (IOM#0) in drive enclosure 2 with the mini SAS HD cable between enclosures.
Connect the cable in the same way as Step (1).

54 Configuration Guide (Basic)


4. Connecting Cables
Drive Enclosure Connection

Drive enclosure 2

Drive enclosure 1

3 When two controllers are installed, connect Controller 1 next.


(1) Connect the controller enclosure to the drive enclosure.
Connect the DI (IN) port of I/O module 1 (IOM#1) in drive enclosure 2 to the DI (OUT) port of
Controller 1 (CM#1) with the mini SAS HD cable between enclosures.
(i) Connect the plug to be connected to DI (OUT) port, to the DI (OUT) port of the Controller 1
(CM#1) in the controller enclosure.
(ii) Connect the plug to be connected to the DI (IN) port, to the DI (IN) port of the I/O module 1
(IOM#1) in drive enclosure 2.

Drive enclosure 2

Drive enclosure 1

Controller enclosure

(2) Connect between the drive enclosures.


Connect the DI (OUT) port of I/O module 1 (IOM#1) in drive enclosure 2 to the DI (IN) port of I/O
module 1 (IOM#1) in drive enclosure 1 with the mini SAS HD cable between enclosures.
Connect the mini SAS HD cable between enclosures in the same way as Step (1).

55 Configuration Guide (Basic)


4. Connecting Cables
Administration Terminal Connection

Drive enclosure 2

Drive enclosure 1

Administration Terminal Connection


Connect an administration terminal to the ETERNUS DX.
Connect the administration terminal to the RMT port of Controller 0 (CM#0) on the controller enclosure directly
with the LAN cable (for operation management).
For the setup information of the administration terminal, refer to "Preparation and Setup for the Administration
Terminal" (page 24).

Note
The ETERNUS DX and the administration terminal must be connected directly since the network
environment of the ETERNUS DX is set using the administration terminal for the initial setup of the
ETERNUS DX.

Figure 6 Administration Terminal Connection for Initial Setup

Administration terminal

LAN port
LAN cable

RMT port of Controller 0 (CM#0)

Controller
enclosure

56 Configuration Guide (Basic)


4. Connecting Cables
LAN Cable Connection (for Operation Management)

LAN Cable Connection (for Operation Management)


The ETERNUS DX must be connected to a LAN to perform actions via ETERNUS Web GUI or ETERNUS CLI such as
settings, maintenance operations, monitoring the device status, and using remote support.
Prepare the required number of LAN cables for the network environment of the customer.
The following procedure explains how to connect the LAN cable.

Caution
When the LAN switch that is to be used has the Spanning Tree Protocol (STP) function enabled, connection
to the ETERNUS DX may fail. Use the following settings to disable the STP function:
• When the STP function is not necessary for the network configuration:
Disable the STP function of the LAN switch.
• When the STP function is necessary for the network configuration:
Disable the STP function of the LAN switch port only for the ETERNUS DX connection or perform the Port-
Fast setting.

IMPORTANT
• To help with LAN cable management and prevent incorrect connections, attach labels to the LAN cables
and make a note of connection origins and destinations.
• When connecting LAN cables, check the connector orientation and then firmly push it all the way in.
When disconnecting LAN cables, depress the tab, then pull out the connector.

Note
This section uses a controller enclosure with two controllers as an example to explain the connection
procedure. When one controller is installed, this procedure is only applied to Controller 0 (CM#0).

1 Connect the LAN cable to the ETERNUS DX.


Connect the LAN cable connectors to the MNT ports of the Controller 0 (CM#0) and Controller 1 (CM#1) for
the ETERNUS DX.

• When connecting the LAN cables, position them so that they will not
obstruct replacement of the power supply unit or controllers by the
maintenance engineer.

57 Configuration Guide (Basic)


4. Connecting Cables
Power Synchronized Unit Connection

2 When the RMT port is used, connect the connector of the LAN cable to the RMT port of Controller 0 (CM#0)
and Controller 1 (CM#1).

3 Connect the LAN cables of the MNT port to the network of the customer. If the RMT port is used for remote
support, connect the LAN cable of the RMT port to the network for remote support.

Power Synchronized Unit Connection


When using a power synchronized unit for power control, connect the power synchronized unit to the ETERNUS
DX.
Refer to "Configuration Guide (Power Synchronized Unit)" for details about power synchronized units, the
procedure for connecting power synchronized units to the ETERNUS DX, and required settings.

Power Cord Connection

Connect the power cords to the ETERNUS DX.

IMPORTANT
• The controller enclosure and drive enclosure have two power supply units (PSU#0 and PSU#1).
Make sure that the power cords are connected to all the power supply units.
• To help with power cord management and prevent incorrect connections, attach labels to the power
cords and make a note of connection origins and destinations.

When No Power Distribution Units Are Installed


The following procedure explains how to connect the power cords when no power distribution units are
installed.

1 Connect the power cord to the ETERNUS DX.


(1) Connect the power cord plugs to the power inlets of the power supply units.

(2) Fasten the plug of the power cord with the release tie.
Wrap the release tie around the power cord and fasten the release tie from either side. Make sure
that the release tie is not loose.

58 Configuration Guide (Basic)


4. Connecting Cables
Power Cord Connection

2 Connect the power cords to the socket.


Connect the plug at the other end of each power cord to the socket.

IMPORTANT
Connecting two power cords for each enclosure to different two power supply facilities improves the
availability of the power supply facilities against failures.

• Do not use the server service outlet to connect a power cord for the
ETERNUS DX.

When Power Distribution Units (1U) Are Installed


The following procedure explains how to connect the power cord when a 1U power distribution unit is installed.

1 Remove the power cord clamps or the cable holders from the power distribution unit.

Cable holder

Power distribution unit

2 Connect the power distribution unit outlets and power supply unit inlets with the power cords (AC output
cables).
The procedure to connect the power supply unit is same as Step 1 in "When No Power Distribution Units
Are Installed" (page 58).

59 Configuration Guide (Basic)


4. Connecting Cables
Power Cord Connection

The following figure shows an example of AC output cable connection:


PSU#0 PSU#1
Inlet Drive enclosure 1 Inlet

Controller enclosure

PSU#0 Inlet PSU#1 Inlet

Power distribution unit Outlet


OUTPUT #1-1

Outlet Outlet Outlet


OUTPUT #0-1 OUTPUT #0-2 OUTPUT #1-2

: Connect OUTPUT#0-n of the Power distribution unit to the PSU#0 inlet of the ETERNUS storage system.
: Connect OUTPUT#1-n of the Power distribution unit to the PSU#1 inlet of the ETERNUS storage system.

3 Connect the power cord (AC input cable) plugs to the inlets of the power distribution unit.

Inlet Inlet
INPUT #0 INPUT #1

Power distribution unit

4 Use the power cord clamps to prevent the power plugs from coming unplugged.
Attach the power cord clamps removed in Step 1.

5 Connect the plugs on the other end of the power cords (AC input cables) that were connected in Step 3 to
the sockets.

IMPORTANT
Power supply failure can be prevented by connecting the power cords (AC input cables) on the
INPUT#0 side and the INPUT#1 side to different power sources.

60 Configuration Guide (Basic)


4. Connecting Cables
Power Cord Connection

When Power Distribution Units (2U) Are Installed


The following procedure explains how to connect the power cords when a 2U power distribution unit (16 outlet
type) is installed.

1 Remove the cable holders from the power distribution unit.


Loosen the eight M3 screws on both sides of the cable holder to remove it.

Cable holder

M3 screw

M3 screw

2 Connect the power distribution unit outlets and power supply unit inlets with the power cords (AC output
cables).
The procedure to connect the power supply unit is same as Step 1 in "When No Power Distribution Units
Are Installed" (page 58).

IMPORTANT
• Connect the PSU#0 power cord to power distribution unit#0 (the lower power distribution unit).
Connect the PSU#1 power cord to power distribution unit#1 (the higher power distribution unit).
• For the high-density drive enclosure, connect the PSU#0 and PSU#2 power cords to power
distribution unit#0 (the lower power distribution unit). Connect the PSU#1 and PSU#3 power
cords to power distribution unit#1 (the higher power distribution unit).

61 Configuration Guide (Basic)


4. Connecting Cables
Power Cord Connection

The following figures show a connection diagram of AC outlet cables.

Drive enclosure 5

Drive enclosure 4

Drive enclosure 3

Drive enclosure 2

PSU#2 Inlet Drive enclosure 1 PSU#3 Inlet

PSU#0 Inlet PSU#1 Inlet

Controller enclosure

PSU#0 Inlet PSU#1 Inlet


OUT6

OUT8
OUT1

OUT4
OUT2

OUT5

OUT7
OUT3

Power distribution unit #1


OUT6

OUT8
OUT1

OUT4
OUT2

OUT5

OUT7
OUT3

Power distribution unit #0

: Connect OUTn of the power distribution unit #0 to the PSU#0 inlet of the ETERNUS storage system.

: Connect OUTn of the power distribution unit #1 to the PSU#1 inlet of the ETERNUS storage system.

3 Use the power cord clamps to prevent the power plugs from coming unplugged.
Attach the power cord clamps removed in Step 1.

4 Connect the plugs on the other end of the power cords (AC input cables) that are attached to the power
distribution unit to sockets.

IMPORTANT
Power supply failure can be prevented by connecting the power cords (AC input cables) on the
power distribution unit #0 side and the power distribution unit #1 side to different power sources.

62 Configuration Guide (Basic)


4. Connecting Cables
Power Cord Connection

AC input cables

Power
distribution
unit#1
Power
distribution
unit#0

Connect to power outlets.

When the DC Power Type Is Used


Connect the power cords to the ETERNUS DX.
The following procedure explains how to connect a DC power cord.

IMPORTANT
• One 40A fast-trip double-pole DC-rated circuit breaker must be located between each power supply unit
of the ETERNUS DX and each DC power supply device.
• Do not use any power cord other than the one provided with the ETERNUS DX. Also, do not use it with
other devices or purposes.
The power cord that is provided has been designed and tested for safe connection with the ETERNUS DX.
• To help with DC power cord management and prevent incorrect power cord connection, attach labels to
the DC power cords and make a note of the connection origins and destinations.
• When connecting DC power cords, check the connector orientation and then firmly push it all the way in.
When disconnecting DC power cords, depress the tab, then pull out the connector.

1 Stop power from a DC power supply device by using a circuit breaker.

2 Connect the DC power cords to the ETERNUS DX.

IMPORTANT
Each enclosure has two (PSU#0 and PSU#1) power supply units. Make sure that both of the power
supply units are connected with DC power cords.

Connect the DC power cord plugs to the power inlets of the power supply units.

63 Configuration Guide (Basic)


4. Connecting Cables
Power Cord Connection

3 Connect the DC power cords to the DC power supply devices via circuit breakers.
Attach the required connector type to the DC power cords for circuit breaker connection (a GND connector
can be directly attached to a DC power supply device).
An external view of a DC power cord is shown below.

Terminal connector

Green/Yellow (GND)
DC power cord

Blue (-48VDC/-60VDC) Connect to


DC power supply device
via circuit breaker
Black (RTN)

Power plug connector details

GND RTN
-48VDC/-60VDC

4 Turn on the circuit breaker.

64 Configuration Guide (Basic)


5. General Settings
This chapter explains how to set up the ETERNUS DX.

■ Initial Settings after Installation


The following settings must be performed when an ETERNUS DX is installed.

● Storage Management
Perform the device information settings and the network connection settings. All of the required settings
can be performed by following the instructions that are displayed when the Initial Setup 1 wizard is used.

● Firewall Settings
Select whether to enable or disable connections for each service that is to be used via the LAN for operation
management.

● RAID Configuration Settings


Register the RAID groups, the volumes, and the hot spares in the ETERNUS DX. For details on these settings,
refer to "6. Configuration Settings for RAID Groups or Thin Provisioning" (page 108).

● Monitoring Settings
Perform the settings to enable constant monitoring of the ETERNUS DX status. For details on these settings,
refer to "8. Monitoring Settings" (page 159).

● Power Control Setup


Perform the ETERNUS DX power control settings. For details on these settings, refer to "9. Power Control
Setup" (page 179).

● Host Interface Management


Perform the settings for SAN connections with the server. For details on these settings, refer to "7. Host
Interface Management" (page 133).

65 Configuration Guide (Basic)


5. General Settings

■ Example of the ETERNUS DX Environment Settings


Create the operation volume and backup volume in the ETERNUS DX.

Figure 7 Example of Creating Operation Volume and Backup Volume

Operation volume
ETERNUS DX
Standard

RAID group 0 (RAID5)


main 1TB

600GB × 5

Generation management volume


RAID group 1 (RAID5)
Snap Data Volume (SDV) (*1)

sdv0 sdv1 sdv2 sdv3 sdv4 sdv5 sdv6


1.92TB × 3

Copy data destination volume

Snap Data Pool Volume (*2)

sdpv 500GB

*1: SDV is used as the copy destination for SnapOPC+ and stores generation data.
*2: SDPV is the expansion area of the SDV and is used to configure the Snap Data Pool (SDP) area.

66 Configuration Guide (Basic)


5. General Settings
Powering On

Powering On
This section explains how to turn on the ETERNUS DX.

Switching On and Off the Main Line Switch on the Power Distribution Unit
Turn the main line switch of the power distribution unit to the ON position (marked "|").

IMPORTANT
Make sure all of the main line switches are in the ON position.

● For 1U

Figure 8 ON Position (Marked "|") of the Main Line Switches on a 1U Power Distribution Unit

Main line switch

● For 2U

Figure 9 ON Position (Marked "|") of the Main Line Switches on a 2U Power Distribution Unit

Main line switch

Switching On and Off the PSU Switch on the Power Supply Unit
Move the PSU switch on the power supply unit of the controller enclosure and drive enclosures to the ON
position (marked "|"). Note that power supply units for the ETERNUS DX500 S5/DX600 S5/DX900 S5 controller
enclosures and high-density drive enclosures do not have PSU switches.

IMPORTANT
Make sure all of the PSU switches are in the ON position.

67 Configuration Guide (Basic)


5. General Settings
Powering On

Note
Do not turn the main line switches of the power distribution units and the PSU switches on the ETERNUS
DX to the OFF position.

Figure 10 ON Position (Marked "|") of the PSU Switch on a Power Supply Unit
ETERNUS DX60 S5/DX100 S5/DX200 S5

Drive enclosure

PSU#0 PSU#1

Controller enclosure

PSU#0 PSU#1

Drive enclosure
PSU#0 PSU#1

ETERNUS DX500 S5/DX600 S5/DX900 S5

ETERNUS DX100 S5 (DC power type)

Drive enclosure

PSU#0 PSU#1

Controller enclosure

PSU#0 PSU#1

68 Configuration Guide (Basic)


5. General Settings
Powering On

Power is supplied to an enclosure.


• For the controller enclosure, the POWER LED on the power supply unit blinks green.
• For the drive enclosure, the POWER LED on the power supply unit emits green lights and the fan revolves at
high speed for 30 seconds.

ETERNUS DX60 S5/DX100 S5/DX200 S5

Drive enclosure

PSU#0 PSU#1

Controller enclosure

PSU#0 PSU#1

POWER LED

Drive enclosure

PSU#0 PSU#1

ETERNUS DX500 S5/DX600 S5/DX900 S5

ETERNUS DX100 S5 (DC power type)

Drive enclosure

PSU#0 PSU#1

Controller enclosure

PSU#0 PSU#1

POWER
LED

69 Configuration Guide (Basic)


5. General Settings
Powering On

Powering On
This section explains how to turn on the ETERNUS DX.
The following methods can be used to turn the power on:
• Via the power switch
Press the Power switch to turn on the ETERNUS DX.
The following methods can be used to turn the power on by linking with the server.
• Via the power synchronized unit
Use the power synchronized unit to turn on the ETERNUS DX.
• Via the Wake On LAN function
Use the Wake On LAN function to turn on the power.
Follow the procedure below to turn on the ETERNUS DX.

IMPORTANT
• After turning the power on, it takes approximately five minutes for the ETERNUS DX to reach the READY
state (READY LED [ ] turns on). This should be taken into consideration for scheduled operations.

Table 3 Time Required to Turn the Power On


Deduplication/ Deduplication/
VLAN/Bonding maximum
Compression function Compression function Unified configuration (*1)
Model configuration
is disabled is enabled

Normal Error Normal Error Normal Error Normal Error

DX60 S5 Approx. 5 Max. 18 — — — — — —


minutes minutes

DX100 S5 Approx. 5 Max. 18 — — Approx. 10 Max. 40 Approx. 20 Max. 50


minutes minutes minutes minutes minutes minutes

DX200 S5 Approx. 5 Max. 18 Approx. 9 Max. 22 Approx. 10 Max. 40 Approx. 20 Max. 50


minutes minutes minutes minutes minutes minutes minutes minutes

DX500 S5 Approx. 5 Max. 18 Approx. 12 Max. 25 Approx. 10 Max. 42 Approx. 22 Max. 53


minutes minutes minutes minutes minutes minutes minutes minutes

DX600 S5 Approx. 7 Max. 20 Approx. 15 Max. 28 Approx. 12 Max. 44 Approx. 24 Max. 55


minutes minutes minutes minutes minutes minutes minutes minutes

DX900 S5 Approx. 10 Max. 20 Approx. 14 Max. 24 — — — —


(*2) minutes minutes minutes minutes

*1: The time required to turn the power on for the Unified configuration depends on the NAS configuration (or the number of
shared folders and the number of VLAN/Bonding configurations).
*2: The ETERNUS DX900 S5 supports the Compression function only.

• Before turning the server on, check that the ETERNUS DX and the network devices that connect the
ETERNUS DX and the server are all in READY status.
If the server is turned on while any of these devices are not in READY status, the server may not be able
to recognize the ETERNUS DX.
• To turn on the ETERNUS DX by linking with the server, the server must wait until the ETERNUS DX is in
the READY state.
• If the Auto Power function is enabled via ETERNUS Web GUI or ETERNUS CLI, the ETERNUS DX is
automatically turned on when power is supplied to the ETERNUS DX.
• If the Power Resume function is enabled via ETERNUS Web GUI or ETERNUS CLI, the ETERNUS DX is
automatically turned on after the power is restored.

70 Configuration Guide (Basic)


5. General Settings
Powering On

• If the REMOTE LED ( ) of the ETERNUS DX500 S5/DX600 S5/DX900 S5 is green, turn on the ETERNUS
DX500 S5/DX600 S5/DX900 S5 via a power synchronized unit.
• After power-off, wait for about one minute before turning power on again.
• If the ETERNUS DX turns off abnormally due to problems such as a power failure, it takes approximately
10 minutes (max.) longer for the ETERNUS DX60 S5/DX100 S5/DX200 S5 and the ETERNUS DX500 S5,
approximately 15 minutes (max.) longer for the ETERNUS DX600 S5, or approximately 20 minutes
(max.) longer for the ETERNUS DX900 S5 to reach the READY state the next time the ETERNUS DX is
turned on.

1 Press the Power switch of the controller enclosure or the frontend enclosure.

Power switch
Power switch

Controller enclosure

ETERNUS DX60 S5/DX100 S5/DX200 S5 ETERNUS DX500 S5/DX600 S5

Power switch

Frontend enclosure

ETERNUS DX900 S5

The POWER LED ( or ) on each enclosure is turned on.

71 Configuration Guide (Basic)


5. General Settings
Powering On

2 Check that the READY LED ( ) of the controller enclosure or the frontend enclosure is lit up.

Drive enclosure

Controller enclosure

ETERNUS DX60 S5/DX100 S5/DX200 S5 ETERNUS DX500 S5/DX600 S5

Drive enclosure

Controller enclosure

Frontend enclosure

ETERNUS DX900 S5

For details about the time required until the READY LED is turned on, refer to "Important" of "Powering
On" (page 70).
When checking the connection between the administration terminal and the ETERNUS DX, execute the
"ping" command at the administration command prompt. An example of ping execution is shown below.
("192.168.1.1" is the default IP address for the ETERNUS DX)

ping 192.168.1.1

If the execution results in an error, check the network settings of the administration terminal.

IMPORTANT
When communication cannot be established even after the RMT port of Controller 0 (CM#0) is
connected to the LAN port of the PC terminal, make sure that the MASTER LED of Controller 0
(CM#0) is turned on. When two controllers are installed and the MASTER LED of Controller 1 (CM#1)
is turned on, use the RMT port of Controller 1 (CM#1).

72 Configuration Guide (Basic)


5. General Settings
Startup of ETERNUS Web GUI

Startup of ETERNUS Web GUI


Start up ETERNUS Web GUI via the Web browser of the connected terminal.
If the settings of the Web browser are incorrect, ETERNUS Web GUI may not be connected. For details on these
settings, refer to "Configuration Guide (Web GUI)".

1 Check that the administration terminal is connected to the ETERNUS DX.

2 Enter "http://IP address of the ETERNUS DX/" to the address bar in the web browser (Default IP address is
"192.168.1.1").
The login screen for ETERNUS Web GUI appears.

Note
The default number of port that is used for http connection is "80".

When Using the Remote Installation Function


When operating and managing multiple ETERNUS DX storage systems that are connected to the network, use
the DHCP server to simplify the procedure for connecting each ETERNUS DX and administration terminal (this
function is called as the "Remote Installation" function).
• If the MNT port of the ETERNUS DX is connected to the network, the DHCP server assigns a network address to
the MNT port. The network setup information for ETERNUS DX storage systems in the network is collected by
using a Windows application called ETERNUS Connection Detecting tool (ECD). Log in to ETERNUS Web GUI on
the network address of the MNT port where information was collected.
To use the Remote Installation function with the DHCP server, satisfying the network conditions and obtaining
an ECD are required. Contact your maintenance engineer.
If the Remote Installation function is not used, the network environment is configured in the usual way: the
maintenance engineer configures the network environment of the MNT port by connecting the administration
terminal to the RMT port of the ETERNUS DX (with the ETERNUS DX500 S5/DX600 S5/DX900 S5, connect the
administration terminal to the FST port).
• The MNT port network environment settings must be set with an authorized IP address. Some functions are
not available if the network environment settings are incomplete.

When Using the SSL (https) Connection


The "SSL server certificate" or the "self-signed SSL certificate" must be registered in the ETERNUS DX in advance.
• When registering "SSL server certificate"
1 Use either of the following methods to obtain an "SSL server certificate" from the certification authority.
- Use the [Create Key/CSR] function (*1) of the ETERNUS DX to download a Certificate Signing Request
(CSR) and send it to the certification authority.
- Use a generally provided tool or website other than the ETERNUS DX.
2 If the "SSL server certificate" is in the PFX format, convert it to the PEM format (*1).
3 Use the [Register SSL Certificate] function (*1) to register the obtained "SSL server certificate".
• When registering a "self-signed SSL certificate" that is created using the ETERNUS DX
1 Create the "self-signed SSL certificate" using the [Create Self-signed SSL Certificate] function (*1).

73 Configuration Guide (Basic)


5. General Settings
Startup of ETERNUS Web GUI

2 Register the created "self-signed SSL certificate" in the storage system as described in "Installing the
Security Certificate" in "Configuration Guide (GUI)".
*1: Refer to "Create Key/CSR", "Register SSL Certificate", and "Create Self-signed SSL Certificate" in "ETERNUS Web GUI User's Guide" for details.

Login
The procedure for logging in is as follows:

1 Click the [Option] button in the login screen, and select the language (English or Japanese).

2 Enter the User ID and Password.


The User ID and the Password vary depending on which account is being used to log in.

User ID: root


Password: root (by default)

Caution
Up to 16 users can be logged in concurrently from ETERNUS Web GUI (the number of users that are
logged from ETERNUS CLI is not included). 17 or more users cannot be logged in concurrently.
Also note that when another user is already logged in and performing one of the following
operations, a warning message appears and some functions cannot be used. Confirm the current
ETERNUS Web GUI usage state and start operation.
• When applying controller firmware
• When applying disk firmware
• When performing the RAID group diagnosis
• When performing the disk diagnosis

Note
Refer to "Define Role" in "ETERNUS Web GUI User's Guide" for user accounts.

3 Click the [Login] button.


The operation screen appears.

74 Configuration Guide (Basic)


5. General Settings
Initial Setup

Initial Setup
This section describes the Initial Setup function for the ETERNUS DX.
This function performs the required initial settings that must be set before operating the ETERNUS DX on a series
of wizard screens.

● Initial Setup 1
This function performs the minimum settings required before operating the ETERNUS DX on a series of
wizard screens.

● Firewall Settings
Set the firewall for each service.

● Initial Setup 2
Makes the reporting settings for when an error occurs in the ETERNUS DX on a series of wizard screens.
The settings can be omitted if the reporting function will not be used.

● Smart Setup Wizard


With the ETERNUS DX, configure the settings that are required for access from the host (server) to Thin
Provisioning Volumes on a series of wizard screens.

Caution
• If the browser is shut down during execution of Initial Setup, other functions will no longer be
available.
In this case, forcibly log in using the same user ID, and perform Initial Setup 1 again from the
beginning. However, if you have already reached Initial Setup 2, the wizard is executed from the
beginning of Initial Setup 2.
• The available setting items depend on the role of the logged in user.
• If the system message "Currently Network Configuration is set to factory default." is displayed, the
network environment settings for the MNT port must be performed. The following functions in the
[Initial Setup 2] wizard are not displayed until the network environment settings are complete.
- Setup SNMP Agent Basic Interface
- Setup SNMP Manager
- Setup SNMP Agent MIB Access View
- Setup SNMP Agent User
- Setup SNMP Agent Community
- Setup SNMP Agent Trap
- Setup E-Mail Notification
- Setup Syslog

Note
• The [Initial Setup 1] wizard is displayed when a user with the required policies for this setting
performs the first login after installing the ETERNUS DX.
After the [Initial Setup 1] is complete and the user with the required policies logs in again, the
[Initial Setup 2] wizard is displayed.
For users without the required policies, the [Overview] screen is displayed at the first login.
• The settings made in the Initial Setup can be changed individually later.

75 Configuration Guide (Basic)


5. General Settings
Initial Setup

Initial Setup 1
This section explains Initial Setup 1. Refer to "System Settings" in "ETERNUS Web GUI User's Guide" for details.
1 Set Storage System Name
Register the name, administrator, and installation site of the ETERNUS DX.
2 Change User Password
Change the password for the default account that is currently logged in before starting to use the ETERNUS
DX.
3 Set Thin Provisioning
If using the Thin Provisioning function, select "Enable" and set the maximum pool capacity.
4 Register Advanced Copy License
If using the Advanced Copy function, register the license here.
5 Register SED Authentication Key
Register the Self Encrypting Drive (SED) Authentication Key to enable encryption of the SEDs.
6 Setup Network Environment
Set the environment for the ETERNUS DX to communicate on the network such as IP address and subnet
mask.

Log out when the settings are complete. Log in again, and then proceed to "Initial Setup 2 (Optional)" (page
85).
The procedure to perform Initial Setup 1 is as follows:

1 Click [Initial Setup] in [Action].

Note
The [Initial Setup] screen is displayed after logging in for the first time.

76 Configuration Guide (Basic)


5. General Settings
Initial Setup

2 Click the [Next >>] button.

Initial Setup starts.

3 Proceed to [Set Storage System Name].


(1) Specify the parameters.

The main setting items are as follows.


• Name (Required)
• Installation Location
• Administrator
• Description

77 Configuration Guide (Basic)


5. General Settings
Initial Setup

Caution
Once the storage system name has been specified, it cannot be deleted (it can be changed).
To change the storage system name, use the [Modify Storage System Name] function in
"ETERNUS Web GUI User's Guide".

Note
If not logging in for the first time, click the [Skip] button to proceed to the next screen
without setting.

(2) Click the [Next >>] button.


(3) A confirmation screen appears. Click the [OK] button.
Setting of the storage system name starts.
(4) Click the [Done] button.

4 Proceed to [Change Password].


(1) Specify the parameters.

The main setting items are as follows.


• Old Password
• New Password
• Confirm New Password

Caution
If either of the following is displayed for the "Days To Password Change" field in "User
Information", the password cannot be changed during that period.
• Number of days
• Less than 24 hours

78 Configuration Guide (Basic)


5. General Settings
Initial Setup

Note
• Click the [Skip] button to proceed to the next screen without setting.
• If a date and time is displayed for the "Last Password Setting Date" field in "User
Information", "Password Policy" for the relevant password is enabled. Check the "Password
Policy" setting before changing the password. Refer to "Modify User Policy" in "ETERNUS Web
GUI User's Guide" for details.

(2) Click the [Next >>] button.


(3) A confirmation screen appears. Click the [OK] button.
Changing of the password starts.
(4) Click the [Done] button.

5 Proceed to [Set Thin Provisioning].


(1) Specify the parameters.

The main setting items are as follows.


• Thin Provisioning (Enable/Disable)
• Maximum Pool Capacity

Note
Click the [Skip] button to proceed to the next screen without setting.

(2) Click the [Next >>] button.


(3) A confirmation screen appears. Click the [OK] button.
The Thin Provisioning setting starts.
(4) Click the [Done] button.

6 Proceed to [Register Advanced Copy License].


(1) Specify the parameters.
The main setting item is as follows.
• License Key

79 Configuration Guide (Basic)


5. General Settings
Initial Setup

Note
• When using ETERNUS SF AdvancedCopy Manager or ETERNUS SF Express, refer to the
documents that are supplied with ETERNUS SF AdvancedCopy Manager or ETERNUS SF
Express.
• Enter the license key only when "Use License Key" is selected for the license registration
method.
• If the Advanced Copy license key (paid license) is already registered, proceed to [Register
SED Authentication Key].
• Click the [Skip] button to proceed to the next screen without setting.

(2) Click the [Next >>] button.


(3) A confirmation screen appears. Click the [OK] button.
The Advanced Copy license registration is executed.
(4) Click the [Done] button.

7 Proceed to [Register SED Authentication Key].


(1) Click the [Next >>] button.

Note
• If the SED Authentication Key is already registered, proceed to [Setup Network
Environment].
• Click the [Skip] button to proceed to the next screen without setting.

(2) A confirmation screen appears. Click the [OK] button.


SED Authentication Key registration starts.
(3) Click the [Done] button.

80 Configuration Guide (Basic)


5. General Settings
Initial Setup

8 Proceed to [Setup Network Environment].


(1) Specify the parameters.

The main setting items are as follows.


• Select Network Port
• LAN
• IPv4 Settings
• IPv6 Settings

Caution
Set the network environment for the MNT port. If the network environment setting is not
changed from the factory default setting, some functions will not be available. Refer to
"Caution" in "Initial Setup" (page 75) and "Setup Network Environment" in "ETERNUS Web GUI
User's Guide" for details.

Note
Click the [Skip] button to proceed to the next screen without setting.

(2) Click the [Next >>] button.


(3) A confirmation screen appears. Click the [OK] button.
Setting of the network environment starts.
(4) Click the [Done] button.
The completion screen appears.

81 Configuration Guide (Basic)


5. General Settings
Initial Setup

9 Click the [Close] button.

The browser is closed, and Initial Setup 1 is complete.


If the administration terminal is connected to the RMT port, remove the LAN cable.

82 Configuration Guide (Basic)


5. General Settings
Initial Setup

Firewall Settings
Configure the firewall for each service. The settings are required respectively for the MNT port and the RMT port.

Caution
• If both HTTP connection and HTTPS connection are disabled, the ETERNUS DX is inaccessible via ETERNUS
Web GUI.
• If both Telnet connection and SSH connection are disabled, the ETERNUS DX is inaccessible via ETERNUS
CLI.
• If the network environment for the MNT port is not set up, some functions will be unusable. Make sure
to set up the network environment.

1 Start the Web browser and log in to ETERNUS Web GUI with the IP address that is set in Step 8 in "Initial
Setup 1" (page 76).

2 Click the [System] tab on the navigation of the ETERNUS Web GUI screen.

3 Click [Network] in [Category].


The [Network] screen appears.

4 Select the port to be set. Click [Setup Firewall] in [Action].

5 In the [Setup Firewall] screen, specify whether to enable/disable each service.


To enable a service, select the checkbox for that service.

83 Configuration Guide (Basic)


5. General Settings
Initial Setup

• HTTP/HTTPS
This service is enabled when an ETERNUS DX is connected via ETERNUS Web GUI.
Data is encrypted and transferred for HTTPS.
• Telnet/SSH
This service is enabled when an ETERNUS DX is connected via ETERNUS CLI.
Data is encrypted and transferred for Secure SHell (SSH).
• ICMP
This service is enabled when an ICMP connection is allowed.
• Maintenance-Secure
This service is enabled for connections from things such as monitoring software or for using the remote
support function to download firmware between ETERNUS DX storage systems.
SSH encrypts and sends/receives data.
• SNMP
This service is enabled when an ETERNUS DX is connected via the SNMP manager.
• ECD
Change the setting to "Disable".

6 Click the [Set] button.

7 In the confirmation screen, click the [OK] button.


The firewall settings are applied.

8 Check the setting completion message and click the [Done] button.
The screen returns to the [Network] screen.

84 Configuration Guide (Basic)


5. General Settings
Initial Setup

Initial Setup 2 (Optional)

This section explains Initial Setup 2.


Initial Setup 2 sets the various reports that are generated when an error occurs in the ETERNUS DX.
If monitoring the ETERNUS DX, use this wizard to build an environment.
The flow of wizard operations in Initial Setup 2 is shown below.
Refer to "System Settings" in "ETERNUS Web GUI User's Guide" for details.

Note
Some items do not need to be specified depending on the Simple Network Management Protocol (SNMP
version).

1 Set Date and Time


Set the date/time and time zone (ETERNUS DX location) of the internal clock in the ETERNUS DX.
2 Setup SNMP Agent Basic Interface
Set up the SNMP Agent basic interface in the ETERNUS DX.
3 Setup SNMP Manager
Specify the IP address of the SNMP Manager.
4 Setup SNMP Agent MIB Access View
Set the MIB View of the SNMP Agent.
5 Setup SNMP Agent User
Set up the user which accesses the SNMP Agent.
The security level and the MIB access range are configured for each user.

Note
This setting is not required when SNMPv1 or SNMPv2c is used for SNMP communication.

6 Setup SNMP Agent Community


Set up the SNMP Agent Community.

Note
This setting is not required when SNMPv3 is used for SNMP communication.

7 Setup SNMP Agent Trap


Set up the environment to send notification of events that occur in the ETERNUS DX to the SNMP Agent
Manager by an SNMP Trap.
8 Setup E-Mail Notification
Set the E-mail notification for events that occur in the ETERNUS DX.
9 Setup Syslog
Set the external servers (Syslog server) for sending logs of events that are detected by the ETERNUS DX.

85 Configuration Guide (Basic)


5. General Settings
Initial Setup

The procedure to perform Initial Setup 2 is as follows:

1 Click [Initial Setup] in [Action].

Note
• When logging in again after Initial Setup 1 is complete, the [Initial Setup 2] screen appears.
• If all of the settings of Initial Setup 2 are not performed, click the [All Skip] button to exit the
Initial Setup wizard.

2 Click the [Next >>] button.

Initial Setup restarts.

86 Configuration Guide (Basic)


5. General Settings
Initial Setup

3 Proceed to [Set Date and Time].


(1) Specify the parameters.

The main setting items are as follows.


• Date/Time Settings
• Time Zone Settings
• Daylight Saving Time Settings
• NTP Settings

Note
Click the [Skip] button to proceed to the next screen without setting.

(2) Click the [Next >>] button.


(3) A confirmation screen appears. Click the [OK] button.

Caution
If Yes" is selected for "Synchronize with NTP Server" when there is no NTP server connection or
when communication with the NTP server is unstable, the required time for the date and time
setting may take longer. Wait until the screen is updated. Even if connection to the NTP server
fails, the date and time setting appear as though they have completed. To confirm that the
ETERNUS DX is successfully connected to the NTP server, start this function again and check
"Access Status" in the "NTP Settings" field. Refer to "Modify Date and Time" in "ETERNUS Web
GUI User's Guide" for details.

Setting of the date and time starts.


(4) Click the [Done] button.

87 Configuration Guide (Basic)


5. General Settings
Initial Setup

4 Proceed to [Setup SNMP Agent Basic Interface].


(1) Specify the parameters.

The main setting items are as follows.


• SNMP Function
• LAN Port used for SNMP
• Authentication Failure
• Engine ID
• MIB-II RFC Version

Note
Click the [Skip] button to proceed to the next screen without setting.

(2) Click the [Next >>] button.


(3) A confirmation screen appears. Click the [OK] button.
Setting of the SNMP Agent basic starts.
(4) Click the [Done] button.

5 Proceed to [Setup SNMP Manager].


(1) Click the [Add] button.

Note
Click the [Skip] button to proceed to the next screen without setting.

88 Configuration Guide (Basic)


5. General Settings
Initial Setup

(2) Specify the parameters.

The main setting items are as follows.


• IP Version
• Manager IP Address (IPv4)
• Manager IP Address (IPv6)
(3) Click the [OK] button.
Returns to the original screen.
(4) Repeat Step (1) through Step (3) to configure multiple IP addresses.

89 Configuration Guide (Basic)


5. General Settings
Initial Setup

(5) When the IP addresses are set, click the [Next >>] button.

(6) A confirmation screen appears. Click the [OK] button.


Setting of the SNMP Manager starts.
(7) Click the [Done] button.

6 Proceed to [Setup SNMP Agent MIB Access View].


(1) Click the [Add] button.

Note
Click the [Skip] button to proceed to the next screen without setting.

90 Configuration Guide (Basic)


5. General Settings
Initial Setup

(2) Specify the parameters.

The main setting items are as follows.


• View Name
• Subtree
(3) Click the [OK] button.
Returns to the original screen.
(4) Repeat Step (1) through Step (3) to configure multiple MIB Access Views.
(5) When the setting of the MIB Access Views is complete, click the [Next >>] button.

91 Configuration Guide (Basic)


5. General Settings
Initial Setup

(6) A confirmation screen appears. Click the [OK] button.


Setting of the SNMP Agent MIB Access View starts.
(7) Click the [Done] button.

7 Proceed to [Setup SNMP Agent User].

Note
The [Setup SNMP Agent User] function must be set when using SNMPv3 in SNMP communication
between the SNMP Agent and SNMP Agent Manager.

(1) Click the [Add] button.

Note
Click the [Skip] button to proceed to the next screen without setting.

92 Configuration Guide (Basic)


5. General Settings
Initial Setup

(2) Specify the parameters.

The main setting items are as follows.


• User Name
• MIB View Setting
• Authentication
• Authentication Method
• Authentication Password
• Retype Authentication Password
• Encryption
• Encryption Method
• Encryption Password
• Retype Encryption Password
(3) Click the [OK] button.
Returns to the original screen.
(4) Repeat Step (1) through Step (3) to configure multiple users.

93 Configuration Guide (Basic)


5. General Settings
Initial Setup

(5) When the setting of the user information is complete, click the [Next >>] button.

(6) A confirmation screen appears. Click the [OK] button.


The SNMP Agent User setting starts.
(7) Click the [Done] button.

8 Proceed to [Set SNMP Agent Community].

Caution
The [Setup SNMP Agent Community] function must be used when using SNMPv1 or SNMPv2c in
SNMP communication between the SNMP Agent and SNMP Manager.
The SNMP Agent Community setting is not necessary when using SNMPv3 only.

(1) Click the [Add] button.

Note
Click the [Skip] button to proceed to the next screen without setting.

94 Configuration Guide (Basic)


5. General Settings
Initial Setup

(2) Specify the parameters.

The main setting items are as follows.


• Community Name
• View Name
• Allowed SNMP Manager List
(3) Click the [OK] button.
Returns to the original screen.
(4) Repeat Step (1) through Step (3) to configure multiple communities.

95 Configuration Guide (Basic)


5. General Settings
Initial Setup

(5) When the setting of the community is complete, click the [Next >>] button.

(6) A confirmation screen appears. Click the [OK] button.


The SNMP Agent Community setting starts.
(7) Click the [Done] button.

9 Proceed to [Setup SNMP Agent Trap].


(1) Click the [Add] button.

Note
Click the [Skip] button to proceed to the next screen without setting.

96 Configuration Guide (Basic)


5. General Settings
Initial Setup

(2) Specify the parameters.

The main setting items are as follows.


• Manager No.
• SNMP Version
• Community Name
• User Name
• Port No.
(3) Click the [OK] button.
Returns to the original screen.
(4) Repeat Step (1) through Step (3) to configure information for multiple traps.

97 Configuration Guide (Basic)


5. General Settings
Initial Setup

(5) When the setting of the trap information is complete, click the [Next >>] button.

(6) A confirmation screen appears. Click the [OK] button.


The SNMP Agent Trap setting starts.
(7) Click the [Done] button.

10 Proceed to [Setup E-Mail Notification].


(1) Specify the parameters.

The main setting items are as follows.


• Notification E-Mail Settings

98 Configuration Guide (Basic)


5. General Settings
Initial Setup

• Mail Server Settings

Note
Click the [Skip] button to proceed to the next screen without setting.

(2) Click the [Next >>] button.


(3) A confirmation screen appears. Click the [OK] button.
The E-Mail Notification setting starts.
(4) Click the [Done] button.

11 Proceed to [Setup Syslog].


(1) Specify the parameters.

The main setting items are as follows.


• Send Log
• Domain Name/IP Address
• Port No.
• LAN Port

Note
Click the [Skip] button to proceed to the next screen without setting.

(2) Click the [Next >>] button.


(3) A confirmation screen appears. Click the [OK] button.
The Syslog setting starts.
(4) Click the [Done] button.
The completion screen appears.

99 Configuration Guide (Basic)


5. General Settings
Initial Setup

12 Click the [Finish] button.

Initial Setup 2 is complete, and the [System] screen appears.

Note
The [Start] screen of the [Smart Setup Wizard] is displayed after all the [Initial Setup] operations
are completed.

100 Configuration Guide (Basic)


5. General Settings
Initial Setup

Smart Setup Wizard


This section explains the Smart Setup Wizard.
With the Smart Setup Wizard, configure the settings that are required for access from the host (server) to Thin
Provisioning Volumes.
To assign volumes other than Thin Provisioning Volumes to a host, refer to "Set Host Response" (page 147) and
"Host Affinity Creation" (page 152).

Caution
• The Smart Setup Wizard cannot be started for the following conditions.
- The Thin Provisioning function is disabled.
- An FC/iSCSI/SAS CA is not activated.
- A Thin Provisioning Pool has not been created and the drive used to create the Thin Provisioning Pool
has not been installed.
• If the host connection is iSCSI, log in to the iSCSI port of the ETERNUS DX from the host before using the
Smart Setup Wizard.
If the login operation for the iSCSI port is not performed from the host, the hosts that are connected via
iSCSI are not displayed.
For details, refer to "Configuration Guide -Server Connection- for iSCSI" for each OS.
• When using the ETERNUS DX900 S5, create a TPP in advance.

Note
• If a Thin Provisioning Pool has not been created, the ETERNUS DX automatically determines the Thin
Provisioning Pool configuration.
- The priority for selecting drive types is as follows.
SSD > SSD SED > Online > Online SED > Nearline > Nearline SED
If multiple drive types exist, the drive type with the highest priority is selected to create a Thin
Provisioning Pool.
To create another Thin Provisioning Pool with the unselected drive types, this wizard cannot be used.
Use the dedicated function provided by this ETERNUS DX to create a Thin Provisioning Pool.
- The RAID levels and the number of drives for RAID groups that configure the Thin Provisioning Pool are
as follows.

Drive type RAID level Number of drives

SSD / SSD SED RAID5 Five or more

Other drive types RAID6 Seven or more

- A Global Hot Spare is registered for each Thin Provisioning Pool.


- The same Deduplication/Compression setting as the Deduplication/Compression mode of the ETERNUS
DX is applied to the Thin Provisioning Pool.
• When this wizard is used, host affinity is automatically set by using the following hosts, ports, and LUN
groups.
- All hosts selected in the [Select Host] screen
- All the CA ports registered in the ETERNUS DX whose port mode is "CA" or "CA/RA" (if multiple types of
CAs are installed in the ETERNUS DX, the selected type of CA is used)
- The LUN groups to which all the volumes selected in the [Select Volume] screen belongs

101 Configuration Guide (Basic)


5. General Settings
Initial Setup

The Smart Setup Wizard is started with one of the following ways.
• After the completion of the Initial Setup 2 wizard, the [Smart Setup Wizard] screen appears.
• Click the [System] tab and then click [Smart Setup Wizard] in [Action].
This section explains the procedure in which the Smart Setup Wizard is started from [Action] in the [System] tab
and "FC" is selected for the CA type. The procedure is similar for cases where "SAS" is selected.
Refer to "ETERNUS Web GUI User's Guide" for the procedure if the CA type is "iSCSI".

1 Click the [System] tab on the navigation of the ETERNUS Web GUI screen.

2 Click [Smart Setup Wizard] in [Action].


The [Start] screen of the Smart Setup Wizard appears.

3 Click the [Next >>] button.

If multiple CA types are installed, the configuration screen for the CA type selection (Step 4) appears.
If only FC type CAs are installed, the configuration screen for the port setting (Step 5) appears.

102 Configuration Guide (Basic)


5. General Settings
Initial Setup

4 CA type selection
Select a CA type to connect with the host and then click the [Next >>] button.
The following shows an example in which [CA Type] is set as [FC].

5 Port setting
Select a connection topology and then click the [OK] button.
The following shows an example in which the FC port connection topology is set as [Fabric].

6 Host selection
(1) Click the [Register] button.

103 Configuration Guide (Basic)


5. General Settings
Initial Setup

(2) Select a host to register in the ETERNUS DX from the host selection list, enter a nickname, and then
click the [OK] button.

(3) Select a host to assign volumes from the host selection list and then click the [Next >>] button.

The screen for automatically creating Thin Provisioning Pool configurations (Step 7) appears.
If a Thin Provisioning Pool has been created, but no volumes are created, the configuration screen
for the creation of new volumes (Step 8) appears.
If a Thin Provisioning Pool has been created and volumes are created, [Select Volume] (Step 9)
appears.

7 Automatic creation of a Thin Provisioning Pool configuration


Configuration of the Thin Provisioning pool that is automatically created is displayed.
Check the configuration and click the [OK] button.
To create a Thin Provisioning Pool with a different configuration, click the [Cancel] button and exit the
Smart Setup Wizard.

104 Configuration Guide (Basic)


5. General Settings
Initial Setup

8 New volume creation


Set the capacity and number of new volumes, select the Thin Provisioning Pool where the volumes are to
be created, and then click the [OK] button.

9 Volume selection
Select a volume to assign to the host and then click the [Next >>] button.

105 Configuration Guide (Basic)


5. General Settings
Initial Setup

10 Configuration confirmation
Check the displayed information and then click the [Next >>] button.

11 A confirmation screen appears. Click the [OK] button.


The configuration of the host connection and host affinity starts.

106 Configuration Guide (Basic)


5. General Settings
Initial Setup

12 A configuration completion screen appears. Click the [Done] button.

107 Configuration Guide (Basic)


6. Configuration Settings for RAID Groups or Thin
Provisioning
This chapter describes the RAID group settings for Standard volumes and Snap Data volumes. This chapter also
describes the Thin Provisioning Pool settings for Thin Provisioning volumes.

Note
The Copybackless function is enabled by the factory default.
To operate with a fixed drive layout, set Copybackless to "Disable" with the "Setup Subsystem Parameters"
function. Refer to "Setup Subsystem Parameters" in "ETERNUS Web GUI User's Guide" for details.

How RAID Groups and Thin Provisioning Are Used


This section describes how RAID groups and Thin Provisioning are used.
RAID groups are areas for storing normal data that are used when the volume capacity requirements can be
estimated in advance. Business volumes and Advanced Copy volumes (Standard type volumes, WSVs, Snap Data
Volumes [SDVs], and Snap Data Pool Volumes [SDPVs]) can be created in RAID groups.
Thin Provisioning manages drives in a pool and assigns them to virtual logical volumes when data is written
from the host. Thin Provisioning enables operations to be started with less drive capacity even if the capacity
requirements cannot be estimated. Thin Provisioning Volumes (TPVs, NAS user volumes, and Deduplication/
Compression Volumes) are created in Thin Provisioning Pools (TPPs).

When Using Standard Volumes


The following sections describe the series of settings when creating Standard volumes.
Not only can new RAID groups be created, adding or changing volumes that are registered in existing RAID
groups can also be performed.
Standard volumes are also used as copy destination volumes for OPC, EC, or REC.
1 Create RAID Group
Create a RAID group (a group of drives that configures the RAID in the ETERNUS DX).
Refer to: "RAID Group Creation" (page 109)
2 Create Volume
Create a volume (drive area in the RAID group). A volume is a structural unit of RAID that can be
recognized from the server. Select "Standard" for "Type".
Refer to: "Operation Volume Creation" (page 112)

108 Configuration Guide (Basic)


6. Configuration Settings for RAID Groups or Thin Provisioning
When Using Standard Volumes

RAID Group Creation


Create RAID groups (groups of drives that configure RAID in the ETERNUS DX) to create volumes.
Create an operation RAID group and a backup RAID group.

Figure 11 RAID Group Creation


Operation RAID group (RG0) Backup RAID group (RG1)

600GB 600GB
1.92TB 1.92TB
600GB 600GB
1.92TB
600GB

RAID5 (4+1) RAID5 (2+1)

Table 4 RAID Group Creation


Usage Item Create mode RAID type Configuration drive

Operation RAID group (copy RG0 Manual RAID5 600GB SAS disk ´ 5
source)

Backup RAID group (copy RG1 Manual RAID5 1.92TB SSD ´ 3


destination)

• Do not uninstall the drives that are installed by default or move them to any other
slot.
Contact your sales representative or maintenance engineer if drives that are
installed by default need to be uninstalled or moved to another slot.

The procedure to register a RAID group is as follows:

1 On the navigation of the ETERNUS Web GUI screen, click the [RAID Group] tab.
The [RAID Group] screen appears.

2 Click [Create] in [Action].


The [Create RAID Group] screen appears.

3 Enter the name of the RAID group that is to be registered. Select "Manual" for "Create Mode".

109 Configuration Guide (Basic)


6. Configuration Settings for RAID Groups or Thin Provisioning
When Using Standard Volumes

4 Set the required items and click the [Create] button.


Name: RG0
Create Mode: Manual
RAID Level: High Capacity (RAID5)
Controlling CM: Automatic
Drives: Select five
A confirmation screen appears.

5 Click the [OK] button.


The RAID group is registered and the registration completion screen appears.

6 Click the [Done] button.


The screen returns to the [RAID Group] screen.

7 After creating an operation RAID group, repeat Step 1 and later steps to create a backup RAID group.
The following screen shows the settings that are displayed when creating a RAID group with the RAID
group name "RG1" and the RAID level "RAID5(2+1)".

110 Configuration Guide (Basic)


6. Configuration Settings for RAID Groups or Thin Provisioning
When Using Standard Volumes

111 Configuration Guide (Basic)


6. Configuration Settings for RAID Groups or Thin Provisioning
When Using Standard Volumes

Operation Volume Creation


Create volumes (areas in the drives of a RAID group) in the RAID group.
Create a 1TB Standard volume in the operation RAID group created in "RAID Group Creation" (page 109).

Figure 12 Operation Volume Creation


Operation RAID group (RG0)

Operation volume

600GB 600GB
1TB
600GB 600GB
600GB main
(Standard)

RAID5 (4+1)

To perform a backup with SnapOPC+, two types of backup volumes (generation data management area and
expansion area where copy data is saved) must be prepared in addition to one for operation. For details about
creation of backup volume, refer to "Generation Management Volume (SDV) Creation" (page 117) and "Copy
Data Destination Volume (SDPV) Creation" (page 118).

Table 5 Operation Volume Creation


Usage Item Capacity Volume type

Operation volume (copy source) main 1TB Standard

Generation management volume sdv0 – 6 1TB (*1) Snap Data Volume

Copy data destination volume sdpv 500GB Snap Data Pool Volume

*1: Though the copy source capacity is specified during creation, the capacity allocated to sdv is approximately 0.1% of the copy source
capacity.

Note
When creation is finished, the volume is automatically formatted. After volume creation, Standard and
SDV become accessible from the host when host affinity setting is completed.
SDPV becomes available when formatting starts after creation.

The procedure to create an operation volume is as follows:

1 Click the [Volume] tab on the navigation of the ETERNUS Web GUI screen.
The [Volume] screen appears.

2 Click [Create] in [Action].


The [Create Volume] screen appears.

3 Set the required items in the [Create Volume] screen and click the [Create] button.
Name: main
Capacity: 1TB
Type: Standard
RAID Group / TPP Selection: Manual
Manual Setting: RG0

112 Configuration Guide (Basic)


6. Configuration Settings for RAID Groups or Thin Provisioning
When Using Standard Volumes

A confirmation screen appears.

4 Click the [OK] button.


The volume is created and the registration completion screen appears.

5 Click the [Done] button.


The screen returns to the [Volume] screen.

6 Then, create SDV and SDPV in the backup RAID group (RG1).
For the creation procedure, refer to "Generation Management Volume (SDV) Creation" (page 117) and
"Copy Data Destination Volume (SDPV) Creation" (page 118).

113 Configuration Guide (Basic)


6. Configuration Settings for RAID Groups or Thin Provisioning
When Using Standard Volumes

Hot Spare Registration


Register the hot spare for the failure of a drive.

Note
• The following two types of hot spare are available:
- Global Hot Spare
This is available for any RAID group.
- Dedicated Hot Spare
This is only available to the specified RAID group (one RAID group).
For a RAID group that contains important data, assign "Dedicated Hot Spare" in order to preferentially
use the hot spare.
• If an Advanced Format disk is used for the hot spare, the sector format information that can be
confirmed from the server may be changed when the disk is used as the hot spare.

• Do not uninstall the drives that are installed by default or move them to any other
slot.
Contact your sales representative or maintenance engineer if drives that are
installed by default need to be uninstalled or moved to another slot.

Global Hot Spare Registration


The procedure to register a Global Hot Spare is as follows:

1 Click the [Component] tab on the navigation of the ETERNUS Web GUI screen. On the [Component]
screen, click [Drives] in [Category].
The [Drives] screen appears.

114 Configuration Guide (Basic)


6. Configuration Settings for RAID Groups or Thin Provisioning
When Using Standard Volumes

2 Select the drive that is to be registered as the Global Hot Spare and click [Assign Global HS] in [Action].

A confirmation screen appears.

3 Click the [OK] button.


The Global Hot Spare is registered and the registration completion screen appears.

4 Click the [Done] button.


The screen returns to the [Drives] screen.

Dedicated Hot Spare Registration


The procedure to register a Dedicated Hot Spare is as follows:

1 Click the [Component] tab on the navigation of the ETERNUS Web GUI screen. On the [Component]
screen, click [Drives] in [Category].
The [Drives] screen appears.

115 Configuration Guide (Basic)


6. Configuration Settings for RAID Groups or Thin Provisioning
When Using Standard Volumes

2 Select the drive that is to be registered as the Dedicated Hot Spare and click [Assign Dedicated HS] in
[Action].

The [Assign Dedicated Hot Spare] screen appears.

3 Select the RAID group for the drive that was selected in Step 2 as the Dedicated Hot Spare. Click the
[Assign] button.

A confirmation screen appears.

4 Click the [OK] button.


The Dedicated Hot Spare is registered and the registration completion screen appears.

5 Click the [Done] button.


The screen returns to the [Drives] screen.

116 Configuration Guide (Basic)


6. Configuration Settings for RAID Groups or Thin Provisioning
When Using SnapOPC+ (SDVs and SDPVs)

When Using SnapOPC+ (SDVs and SDPVs)


The following section describes the series of environment settings when using SnapOPC+ (SDVs and SDPVs).
Not only can new RAID groups be created, adding or changing volumes that are registered in existing RAID
groups can also be performed.
1 Create RAID Group
Create a RAID group (a group of drives that configures the RAID in the ETERNUS DX).
Refer to: "RAID Group Creation" (page 109)
2 Create Volume
Create a volume (drive area in the RAID group). A volume is a structural unit of RAID that can be
recognized from the server. Select "SDV" or "SDPV" for "Type".
Refer to: "Generation Management Volume (SDV) Creation" (page 117) and "Copy Data Destination
Volume (SDPV) Creation" (page 118)

Generation Management Volume (SDV) Creation


Create a generation management volume in the backup RAID group.
Create SDV for seven generations (as a backup area for seven days a week) in the backup RAID group "RG1"
created in "RAID Group Creation" (page 109).

Figure 13 Generation Management Volume (SDV) Creation

Backup RAID group (RG1) Generation management volume

1.92TB 1.92TB
1.92TB
sdv0 - sdv6
(Snap Data Volume)

RAID5 (2+1)

The procedure to create a generation management volume (SDV) is as follows:

1 Click the [Volume] tab on the navigation of the ETERNUS Web GUI screen.
The [Volume] screen appears.

2 Click [Create] in [Action].


The [Create Volume] screen appears.

3 Set the required items in the [Create Volume] screen and click the [Create] button.
Name: sdv
Type: Snap Data Volume
Capacity of source volume: 1TB (*1)
RAID Group / TPP Selection: Manual
Manual Setting: RG1
Number of Volumes: 7 (*2)
*1: Enter the capacity of the copy source volume during creation of SDV.

117 Configuration Guide (Basic)


6. Configuration Settings for RAID Groups or Thin Provisioning
When Using SnapOPC+ (SDVs and SDPVs)

*2: If "7" is specified for the number of volumes, sdv0, sdv1, sdv2, sdv3, sdv4, sdv5, and sdv6 volumes are created.

A confirmation screen appears.

4 Click the [OK] button.


The volume is created and the registration completion screen appears.

5 Click the [Done] button.


The screen returns to the [Volume] screen.

Copy Data Destination Volume (SDPV) Creation


Create a copy data destination volume in the backup RAID group.
Create a volume as an expansion area of SDV in the backup RAID group "RG1" created in "RAID Group Creation"
(page 109).

Figure 14 Copy Data Destination Volume (SDPV) Creation


Backup RAID group (RG1)

Copy data destination volume

1.92TB 1.92TB 500GB


1.92TB
sdpv
(Snap Data Pool Volume)

RAID5 (2+1)

118 Configuration Guide (Basic)


6. Configuration Settings for RAID Groups or Thin Provisioning
When Using SnapOPC+ (SDVs and SDPVs)

The procedure to create a copy data destination volume (SDPV) is as follows:

1 Click the [Volume] tab on the navigation of the ETERNUS Web GUI screen.
The [Volume] screen appears.

2 Click [Create] in [Action].


The [Create Volume] screen appears.

3 Set the required items in the [Create Volume] screen and click the [Create] button.
Name: sdpv
Capacity: 500GB
Type: Snap Data Pool Volume
RAID Group / TPP Selection: Manual
Manual Setting: RG1

A confirmation screen appears.

4 Click the [OK] button.


The volume is created and the registration completion screen appears.

5 Click the [Done] button.


The screen returns to the [Volume] screen.

119 Configuration Guide (Basic)


6. Configuration Settings for RAID Groups or Thin Provisioning
When Using Thin Provisioning Volumes (TPVs)

When Using Thin Provisioning Volumes (TPVs)


The following sections show the series of settings that need to be performed to use Thin Provisioning Pool
Volumes.
Not only can new Thin Provisioning Pool be created, adding or changing volumes that are registered in existing
Thin Provisioning Pools can also be performed.
TPVs can not only be used as virtual logical volumes but also as copy destinations for SnapOPC or SnapOPC+.
1 Set Thin Provisioning
Enable the Thin Provisioning function.
Refer to: "Thin Provisioning Configuration" (page 120)
2 Create Thin Provisioning Pool
Create a Thin Provisioning Pool (groups of drives (which are configured in RAID groups) that configure a
Thin Provisioning Pool).
A volume is a structural unit of RAID. Select "Standard" for "Type".
Refer to: "Thin Provisioning Pool Creation" (page 122)
3 Create Volume
Create a volume (physical drive allocation area in the Thin Provisioning Pool).
A volume is a structural unit of a Thin Provisioning Pool that can be recognized from the server. Select "Thin
Provisioning Volume" for "Type".
Refer to: "Volume Creation" (page 129)

Thin Provisioning Configuration


This function enables the use of the Thin Provisioning function and sets the maximum pool capacity. The chunk
size is determined by the specified maximum pool capacity.
Refer to Table 6 for details.

Caution
Note that the Thin Provisioning function is not provided for the ETERNUS DX60 S5/DX100 S5/DX200 S5 1CM
model. In addition, the [Thin Provisioning] navigation is not displayed for these models.

120 Configuration Guide (Basic)


6. Configuration Settings for RAID Groups or Thin Provisioning
When Using Thin Provisioning Volumes (TPVs)

The procedure to enable the Thin Provisioning function is as follows:

1 Click [Set Thin Provisioning] in [Action].

The [Set Thin Provisioning] screen appears.

2 Select "Enable" for "Thin Provisioning" and then select the "Maximum Pool Capacity" value.

3 Click the [Set] button.

4 A confirmation screen appears. Click the [OK] button.


The Thin Provisioning setting starts.

5 Click the [Done] button to return to the [Settings] screen.

121 Configuration Guide (Basic)


6. Configuration Settings for RAID Groups or Thin Provisioning
When Using Thin Provisioning Volumes (TPVs)

Thin Provisioning Pool Creation


This function creates a Thin Provisioning Pool.

Caution
For the ETERNUS DX60 S5, SSDs or SEDs cannot be used for configuring TPPs.

Table 6 Maximum Number of Pools, Maximum Pool Capacity, and Determined Chunk Size for Each Model
Maximum number of
Model Maximum pool capacity (*2)
pools (*1)

ETERNUS DX60 S5 48 64TB, 128TB 2PB

ETERNUS DX100 S5 72 128TB, 256TB 4PB

ETERNUS DX200 S5 132 256TB, 384TB 6PB

ETERNUS DX500 S5 256 384TB, 512TB, 1PB 16PB

ETERNUS DX600 S5 256 512TB, 1PB, 1.5PB 24PB

ETERNUS DX900 S5 256 512TB, 1PB, 2PB, 4PB, 8PB 128PB

Determined chunk size (*3) 21MB 336MB

*1: Up to 256 pools can be created. When the maximum installation number of drives of a model is 512 or less, the maximum number of
pools is half the maximum installation number of drives.
The maximum pool number is the maximum total number of TPPs and Flexible Tier Sub Pools (FTSPs) that can be created in the
ETERNUS DX.
*2: The maximum pool capacity is specified when "Enable" is selected for the Thin Provisioning function. Refer to "Thin Provisioning
Configuration" (page 120) for details.
The maximum pool capacity is the maximum total capacity for TPPs and Flexible Tier Pools (FTRPs) that can be created in the ETERNUS
DX.
*3: Chunk size is a physical capacity that is assigned to virtual logical volumes created in TPPs and FTRPs when a write occurs from the host.
The chunk size is determined according to the "Maximum Pool Capacity" of the ETERNUS AF/DX when a new TPP is created.
There are two methods to create a TPP; automatic drive selection and manual drive selection.

■ Automatically Selecting Drives to Create TPPs


To create a new TPP automatically, select Drive Type and RAID Level, and input TPP capacity. The Controlling CM
of the RAID groups that configure the TPP is determined automatically.

Caution
When drives that satisfy all the following conditions are installed in the ETERNUS DX, select the drives
manually.
• The drive types are the same
• The drive capacities are the same
• The drive sector format (Advanced Format (AF) compliant or non-AF-compliant) is different

122 Configuration Guide (Basic)


6. Configuration Settings for RAID Groups or Thin Provisioning
When Using Thin Provisioning Volumes (TPVs)

The procedure to create a TPP by selecting drives automatically is as follows:

1 Click [Create] in [Action].

The [Create Thin Provisioning Pool] screen appears.

2 Select "Automatic" for "Create Mode" and specify the other parameters.

The main setting items are as follows.


• New Thin Provisioning Pool
Name
• Automatic Setting
- Drive Type
- RAID Level
- Select Drives

123 Configuration Guide (Basic)


6. Configuration Settings for RAID Groups or Thin Provisioning
When Using Thin Provisioning Volumes (TPVs)

- Thin Provisioning Pool Total Capacity


- Alarm

Caution
When using SSDs, the SSD types (SSD-M/SSD-L) cannot be specified. SSDs that are the same type
and have the necessary capacity in a RAID group to create TPPs are selected. If the number of SSDs
with the same type is insufficient for configuring a RAID group, a TPP is not created. In this case,
reduce the total capacity of the Thin Provisioning Pool.
When using SSD SEDs, the SSD types (SSD-M SED/SSD-L SED) cannot be specified. If "SSD SED" is
selected for the drive type, drives are operated the same way as SSDs.
If "High Performance (RAID1+0)" or "High Capacity (RAID5)" is selected for the RAID level, RAID
groups cannot be created with drives that are 6TB or larger (except SSDs and SSD SEDs).

Note
The maximum capacity that can be used to create new TPPs is displayed to the right of the setting
field for "Thin Provisioning Pool Total Capacity" in the "(Max: xx.xx [PB/TB/GB/MB])" format.

3 Click the [Create] button.

4 A confirmation screen appears. Click the [OK] button.


Create Thin Provisioning starts.

5 Click the [Done] button to return to the [Thin Provisioning Pool] screen.

■ Manually Selecting Drives to Create TPPs


To create a new TPP manually, select Drive Type, RAID Level, and the drive that configures the TPP.

The number of member drives in each RAID group


The number of member drives for each RAID level is listed in the following table.

RAID level Number of member drives

High Performance (RAID1+0) 4, 8, 16, 24

High Capacity (RAID5) 4, 5, 7, 8, 9, 13

High Reliability (RAID6) 6, 8, 9, 10

High Reliability (RAID6-FR) 13, 17, 31

Mirroring (RAID1) 2

Striping (RAID0) 4

Requirements for selecting drives


• The conditions for RAID groups in the TPP are as follows:
- The RAID level (High Performance (RAID1+0) / High Capacity (RAID5) / High Reliability (RAID6) / High
Reliability (RAID6-FR) / Mirroring (RAID1) / Striping (RAID0)) must be the same
- The number of member drives in the RAID group must be the same
- The drive type (Online/Nearline/SSD/Online SED/Nearline SED/SSD SED) must be the same
- If "High Performance (RAID1+0)" or "High Capacity (RAID5)" is selected for the RAID level, RAID groups
cannot be created with drives that are 6TB or larger (except SSDs and SSD SEDs).

124 Configuration Guide (Basic)


6. Configuration Settings for RAID Groups or Thin Provisioning
When Using Thin Provisioning Volumes (TPVs)

• The recommended drive configuration of the RAID group is shown as follows:


- Select drives with the same capacity and speed.
- Select SSDs with the same type (SSD-M/SSD-L/SSD-M SED/SSD-L SED).
- Select the same sector format of drives (AF-compliant/non-AF-compliant).
- If the host connection environment does not support AF, select non-AF-compliant drives. Refer to
"Create RAID Group" in "ETERNUS Web GUI User's Guide" for details.
- When "High Performance (RAID1+0) " or "Mirroring (RAID1)" is selected for the RAID level, allocate the
drives (mirroring pair drives) by dividing them into two or more connection lines (for the ETERNUS
DX500 S5/DX600 S5/DX900 S5).
- When "High Capacity (RAID5)", "High Reliability (RAID6)", or "High Reliability (RAID6-FR)" is selected for
the RAID level, allocate the drives (multiple drives configuring a striping) by dividing them into two or
more connection lines (for the ETERNUS DX500 S5/DX600 S5/DX900 S5).
- Note that these requirements are not applied to the ETERNUS DX60 S5/DX100 S5/DX200 S5.

The procedure to create a TPP by selecting drives manually is as follows:

1 Click [Create] in [Action].

The [Create Thin Provisioning Pool] screen appears.

125 Configuration Guide (Basic)


6. Configuration Settings for RAID Groups or Thin Provisioning
When Using Thin Provisioning Volumes (TPVs)

2 Select "Manual" for "Create Mode" and specify the other parameters.

The main setting items are as follows.


• New Thin Provisioning Pool
Name
• Manual Setting
- Drive Type
- RAID Level
- Fast Recovery Configuration
- Alarm

Note
The maximum capacity that can be used to create new TPPs is displayed in the "Thin Provisioning
Pool Total Capacity" field in the "(Max: xx.xx [PB/TB/GB/MB])" format.

126 Configuration Guide (Basic)


6. Configuration Settings for RAID Groups or Thin Provisioning
When Using Thin Provisioning Volumes (TPVs)

3 Click the [Add] button.

The [Add RAID Group] screen is displayed.

4 Select the Controlling CM of the RAID group and select all the drives to be registered in the RAID group
from the list or from the installation image.
• When selecting drives from the list
Click the [Tabular] tab to select drives from the list. Only unused drives are displayed on the list.
The main setting item is as follows.
- Checkbox to select drives
• When selecting drives from the installation image
Click the [Graphic] tab to select drives from the drive installation image. The installation images of all
the drives installed in the ETERNUS DX are displayed. Checkboxes are displayed for unused drives.

127 Configuration Guide (Basic)


6. Configuration Settings for RAID Groups or Thin Provisioning
When Using Thin Provisioning Volumes (TPVs)

The main setting items are as follows.


- DE selection list box
- Checkbox to select drives

Caution
The drive capacity that is displayed for the Value SSD (SSD-L) differs from the product's actual
capacity. For example, the drive capacity of a "1.92TB SSD-L" is displayed as "2.00TB".

5 Click the [OK] button.


The screen returns to the previous screen. The created RAID group is displayed in the RAID group list.

Note
• Click the [RAID Level] link for the existing RAID group to perform the following operations.
- The number of member drives can be checked. The drives with the checkbox selected in the
displayed screen are the member of the RAID group.
- The Controlling CM and configuration drives of the RAID group can be changed.
- Click the [Delete] button of the target RAID group area in the RAID group list to delete the
newly added RAID group.

6 When creating multiple RAID groups that configure a TPP, repeat Step 3 through Step 5.

Note
• Specify the threshold so that "Warning" is greater than or equal to "Attention".
• The "Attention" threshold can be omitted. When setting the "Attention" threshold, specify a
threshold while the checkbox is selected.

128 Configuration Guide (Basic)


6. Configuration Settings for RAID Groups or Thin Provisioning
When Using Thin Provisioning Volumes (TPVs)

7 After creating a RAID group that configures the TPP, click the [Create] button.

8 A confirmation screen appears. Click the [OK] button.


Create Thin Provisioning Pool starts.

9 Click the [Done] button to return to the [Thin Provisioning Pool] screen.

Volume Creation
This function creates new TPVs.
Detailed information on creating TPVs is provided below.
• Volumes are created in TPPs.
• There are two methods to select a TPP; "Automatic" and "Manual".
• The Thin Provisioning function must be enabled. Refer to "Thin Provisioning Configuration" (page 120) for
details.
• The maximum total capacity of the TPVs that can be created in the ETERNUS DX depends on the maximum
pool capacity specified in "Thin Provisioning Configuration" (page 120). The currently specified maximum pool
capacity is displayed in the [Settings] screen under the [Thin Provisioning] navigation. Refer to "Settings (Thin
Provisioning)" in "ETERNUS Web GUI User's Guide" for details.

129 Configuration Guide (Basic)


6. Configuration Settings for RAID Groups or Thin Provisioning
When Using Thin Provisioning Volumes (TPVs)

■ Automatically Selecting Destinations to Create Volumes


The procedure to create TPVs by selecting destinations automatically is as follows:

1 Click [Create] in [Action].

The [Create Volume] screen appears.

2 Select "Thin Provisioning Volume" for "Type" and "Automatic" for "RAID Group / TPP Selection".
Specify the detailed information of new volumes.

130 Configuration Guide (Basic)


6. Configuration Settings for RAID Groups or Thin Provisioning
When Using Thin Provisioning Volumes (TPVs)

The main setting items are as follows.


• New Volume
- Name
- Capacity
- Allocation
• Automatic Setting
- Drive Type
- RAID Level
- Number of Volumes
- Start of Suffix
- Digits of Suffix

3 Click the [Create] button.

4 A confirmation screen appears. Click the [OK] button.


TPV creation starts.

5 Click the [Done] button to return to the [Volume] screen.

■ Manually Selecting Destinations to Create Volumes


The procedure to create TPVs by selecting a destination TPP manually is as follows:

1 Click [Create] in [Action].

The [Create Volume] screen appears.

2 Select "Thin Provisioning Volume" for "Type" and "Manual" for "RAID Group / TPP Selection".
Specify the detailed information of new volumes and select the TPP in which the volumes are to be
created.

131 Configuration Guide (Basic)


6. Configuration Settings for RAID Groups or Thin Provisioning
When Using Thin Provisioning Volumes (TPVs)

The main setting items are as follows.


• New Volume
- Name
- Capacity
- Allocation
• Manual Setting
- Start of Suffix
- Digits of Suffix
- Volume No.
- Number of Volumes (*1)
*1: Specify the value in the "Number of Volumes" field for the TPP in which the volumes are to be created.

Note
When specifying the volume number, select the "Set Value" checkbox and input the volume
number.

3 Click the [Create] button.

4 A confirmation screen appears. Click the [OK] button.


Volume creation starts.

5 Click the [Done] button to return to the [Volume] screen.

132 Configuration Guide (Basic)


7. Host Interface Management
The following section describes the series of settings when configuring host connection settings.
1 Add LUN Group
Add a LUN group (a group of volumes that are recognized from the server, which is conventionally referred
to as an "affinity group"). For each LUN group, volume numbers are assigned for the Logical Unit Numbers
(LUNs) that are recognized by the host. LUN groups are allowed recognition from the server after host
affinity is set.
Refer to: "LUN Group Addition" (page 134)
2 Set Port Parameters
Set the parameter for the ETERNUS DX side host interface port.
Refer to: "Modify Port Parameters" (page 137)
3 Create CA Port Group
Create a CA port group (a group of CA ports that are connected to the specified host group) that is used for
the server to access the ETERNUS DX.
Refer to: "CA Port Group Creation" (page 145)
4 Set Host Response
Set the appropriate operation mode on which the host makes connection.
Refer to: "Set Host Response" (page 147)
5 Add Host Group
Add the information of any server that accesses the ETERNUS DX via the host interface ports.
When adding a server, create a host group (a host (HBA) group that accesses the same LUN group). In
addition, assign a host response when creating a host group.
Refer to: "Add Host Groups" (page 148)
6 Create Host Affinity
To recognize the LUN group from the server, allocate the host groups with the CA port groups and the LUN
groups.
Refer to: "Host Affinity Creation" (page 152)
7 Modify CA Reset Group
Set member ports for a CA reset group to reduce the effect when ports become inaccessible.
Refer to: "CA Reset Group Settings" (page 158)

133 Configuration Guide (Basic)


7. Host Interface Management
LUN Group Addition

LUN Group Addition


This function creates a new LUN group, and allocates a volume number in the ETERNUS DX to the LUN, which
can be recognized by the host. The following list shows the maximum number of LUN groups that can be created
for each model.
• For the ETERNUS DX60 S5, 128
• For the ETERNUS DX100 S5/DX200 S5, 1024
• For the ETERNUS DX500 S5/DX600 S5, 2048
• For the ETERNUS DX900 S5, 6144
The procedure to create a LUN group is as follows:

1 Click [Add LUN Group] in [Action].

The [Add LUN Group] screen appears.

134 Configuration Guide (Basic)


7. Host Interface Management
LUN Group Addition

2 Specify the LUN group name.

The main setting items are as follows.


• LUN Group Setting
• Name

3 Click the [Add] button.


The [Add LUN] screen appears.

4 Specify the LUN and the number of LUNs for volume allocation and select the volume numbers to start
the allocation to the corresponding LUNs from.

The main setting items are as follows.


• LUN Setting
- Start Host LUNs

135 Configuration Guide (Basic)


7. Host Interface Management
LUN Group Addition

- Number of LUNs
• Select Volume

5 Click the [OK] button.


Returns to the [Add LUN Group] screen.

6 Repeat Step 3 through Step 5 to set multiple allocation information between the LUNs and the volumes.

7 Check the volume allocation information of LUNs to be registered in the LUN group, and then click the
[Create] button.

8 A confirmation screen appears. Click the [OK] button.


Adding LUN group starts.

9 Click the [Done] button to return to the [LUN Group] screen.

136 Configuration Guide (Basic)


7. Host Interface Management
Modify Port Parameters

Modify Port Parameters


This function sets the parameter for the ETERNUS DX side host interface port. The settings vary depending on the
following port types.
• Modify FC Port Parameters
• Modify iSCSI Port Parameters
• Modify SAS Port Parameters

Modify FC Port Parameters


This function sets the parameters for the FC host interface port that connects between the ETERNUS DX and the
host.

Caution
When changing port parameters during operation, stop access from the server that is connected to the
target port. Host access does not need to be stopped to change the port parameters of newly added
Channel Adapter (CA) ports.

The procedure to set FC port parameters is as follows:

1 Select which FC port to set the parameters for (multiple selections can be made) and click [Configure FC
Port] in [Action].

The [Modify FC Port Parameters] screen appears.

137 Configuration Guide (Basic)


7. Host Interface Management
Modify Port Parameters

Note
• Multiple selections can be made from FC ports that have the same SFP type and port mode. Note
that multiple FC ports can also be selected if the SFP types are one of the following combinations.
- A mix of "16G SFP+(SMF)" and "16G SFP+(MMF)"
- A mix of "SFP+(SMF)", "SFP+(MMF)", "Unknown", and "Unmount"
• Multiple ports can be set with the same or with different parameters in a single operation. To set
parameters to multiple ports, select the target ports and specify the parameters for each port.
After the specification is complete, click the [Modify] button.

2 Set the parameters for all of the selected ports.


The following explains how to change the port parameters when the port mode is "CA".

The main setting items are as follows.


• Port Settings
- Port
- Connection
- Set Loop ID
- Loop ID
- Transfer Rate

3 Click the [Modify] button.

Caution
If the Loop ID is changed while a server is operating, reboot the server immediately. If the server is
operated without being rebooted, a warning message may appear or a system failure may occur.

4 A confirmation screen appears. Click the [OK] button.


Setting of the FC port parameters starts.

5 Click the [Done] button to return to the [FC Port] screen.

138 Configuration Guide (Basic)


7. Host Interface Management
Modify Port Parameters

Modify iSCSI Port Parameters


This function sets the parameters for the iSCSI host interface port that connects between the ETERNUS DX and
the host.

Caution
When changing port parameters during operation, stop access from the server that is connected to the
target port. Host access does not need to be stopped to change the port parameters of newly added CA
ports.

The procedure to set iSCSI port parameters is as follows:

1 Select which iSCSI port to set the parameters for (multiple selections can be made) and click [Configure
iSCSI Port] in [Action].

The [Modify iSCSI Port Parameters] screen appears.

Note
• Multiple "1G iSCSI", "10G iSCSI", or "10G Base-T iSCSI" type iSCSI ports with the same port mode can
be selected.
• Multiple ports can be set with the same or with different parameters in a single operation. To set
parameters to multiple ports, select the target ports and specify the parameters for each port.
After the specification is complete, click the [Modify] button.

139 Configuration Guide (Basic)


7. Host Interface Management
Modify Port Parameters

2 Set the parameters for all of the selected ports.


The following explains how to change the port parameters when the port mode is "CA".

The main setting items are as follows.


• Select Port
- Port
• General Information
- iSCSI Settings
• iSCSI Name
• Alias Name
- TCP/IP Settings
• IP Version
• IP Address
• Subnet Mask
• Gateway
• IPv6 Link Local Address
• IPv6 Connect IP Address
• IPv6 Gateway
• TCP Port No.
• TCP Window Scale
• VLAN ID
• Jumbo Frame
- Security Settings
• CHAP
• CHAP User ID
• New Password
• Confirm new Password

140 Configuration Guide (Basic)


7. Host Interface Management
Modify Port Parameters

- General Settings
• Transfer Rate (This item is displayed only when the port type is "10G Base-T iSCSI")
• Additional IP Address Information
- Additional IP Address Settings
• Multiple VLAN
• VLAN ID
• IP Version
• IP Address
• Subnet Mask
• Gateway
• IPv6 Link Local Address
• IPv6 Connect IP Address
• IPv6 Gateway
• TCP Port No.
• TCP Window Scale
• Jumbo Frame

3 In the [Send ping] screen, check the connection status between the target port and the destination
storage system.

The main setting items are as follows.


• Send ping (IP address)
- IP Address
- Send Number
- Result

141 Configuration Guide (Basic)


7. Host Interface Management
Modify Port Parameters

Note
• When the [Discovery] button is clicked for "IPv6 Connect IP Address", the IPv6 connect IP address
can be created automatically from the prefix value that is obtained from the router that is
connected to the ETERNUS DX and the input IPv6 link local address.
• When the [Discovery] button is clicked for "IPv6 Gateway", the gateway information can be
obtained from the connected router.
• When the port mode is "CA" or "CA/RA" and Multiple VLAN is enabled, click the [Add] button to
register up to 15 IP address information for each port.
• To check whether the IP address is allocated correctly and the connection status for the remote
device, click the [Test Connection (ping)] button for "IP Address", "IPv6 Link Local Address", or
"IPv6 Connect IP Address".

4 Click the [Modify] button.

5 A confirmation screen appears. Click the [OK] button.


Setting of the iSCSI port parameters starts.

6 Click the [Done] button to return to the [iSCSI Port] screen.

142 Configuration Guide (Basic)


7. Host Interface Management
Modify Port Parameters

Modify SAS Port Parameters


This function sets the parameters for the SAS host interface port that connects between the ETERNUS DX and the
host.

Caution
• This host interface is supported only for the ETERNUS DX60 S5/DX100 S5/DX200 S5.
• When changing port parameters during operation, stop access from the server that is connected to the
target port. Host access does not need to be stopped to change the port parameters of newly added
Channel Adapter (CA) ports.

The procedure to set SAS port parameters is as follows:

1 Select the SAS port to set the parameters for (multiple selections can be made) and click [Configure SAS
Port] in [Action].

The [Modify SAS Port Parameters] screen appears.

Note
Multiple ports can be set with the same or with different parameters in a single operation. To set
parameters to multiple ports, select the target ports and specify the parameters for each port. After
the specification is complete, click the [Modify] button.

143 Configuration Guide (Basic)


7. Host Interface Management
Modify Port Parameters

2 Set the parameters for all of the selected ports.

The main setting item is as follows.


• Port Settings
- Port
- Transfer Rate

3 Click the [Modify] button.

4 A confirmation screen appears. Click the [OK] button.


Setting of the SAS port parameters starts.

5 Click the [Done] button to return to the [SAS Port] screen.

144 Configuration Guide (Basic)


7. Host Interface Management
CA Port Group Creation

CA Port Group Creation


This function creates a new CA port group, and registers the port to be a member. This section uses FC port
groups as an example to show how to create CA port groups.
An FC port group is a group of ports whose CA type is FC and are connected to a specific host group. The Host
Affinity is specified for each FC port group.
• The maximum number of port groups per ETERNUS DX is 128, irrespective of the CA types.
• The maximum number of ports per port group is 8.
• A port can be a member of multiple port groups.
The procedure to create an FC port group is as follows:

1 Click [Create FC Port Group] in [Action].

The [Create FC Port Group] screen appears.

145 Configuration Guide (Basic)


7. Host Interface Management
CA Port Group Creation

2 Specify the name of the port group to be created and select all the ports to be registered in the port
group.

The main setting item is as follows.


• CA Port Group Setting
Name
• Select Port
Checkbox to select ports

3 Click the [Create] button.

4 A confirmation screen appears. Click the [OK] button.


Registration of the FC port group starts.

5 Click the [Done] button to return to the [CA Port Group] screen.

146 Configuration Guide (Basic)


7. Host Interface Management
Set Host Response

Set Host Response


The host response configures the appropriate operation mode on which the host makes connection. In normal
host connection, the recommended patterns prepared for each OS type in advance or the default settings are
used.

Table 7 Recommended Patterns of Host Responses


Host response name Connection environment

Solaris MPxIO Set this parameter to connect to an Oracle Solaris host and to use the OS standard Multipath Driver (MPxIO).

HP-UX Set this parameter to connect to an HP-UX host.

AIX Set this parameter to connect to an AIX host.

AIX VxVM Set this parameter to connect to an AIX host and to use Veritas Volume Manager (VxVM).

VS850/SVC Set this parameter to connect to an ETERNUS VS850 Virtualization Storage or an IBM SAN Volume Controller
(SVC).

BS2000 Set this parameter to connect to a BS2000 host.

Default Set this parameter for any host connection environments that are not listed above.

For details about the recommended patterns of host responses, refer to "Add Host Response" in "ETERNUS Web
GUI User's Guide".
For details on assigning an appropriate host response, refer to "Configuration Guide -Server Connection-". For
details on modifying the host response settings, refer to "Add Host Response" in "ETERNUS Web GUI User's
Guide".

147 Configuration Guide (Basic)


7. Host Interface Management
Add Host Groups

Add Host Groups


This function creates new host groups and register member hosts.
This section uses FC host groups as an example to show how to create host groups.
An FC host group is a group of hosts (HBAs) whose interface type is FC and accesses the same LUN group. The
Host Affinity is specified for each FC host group.

Table 8 The Number of Host Groups and Hosts That Can Be Registered
Number of host groups Number of hosts (HBAs) Number of hosts (HBAs) Number of hosts (HBAs)
Model
(*1) per ETERNUS DX per ETERNUS DX (*2) per CA port per host group

ETERNUS DX60 S5 512 128 32 8

ETERNUS DX100 S5/ 512 1,024 256 8


DX200 S5

ETERNUS DX500 S5/ 512 4,096 256 8


DX600 S5

ETERNUS DX900 S5 1,536 8,192 256 64

*1: The total number of host groups irrespective of the interface types.
*2: The total number of hosts irrespective of the interface types.

Caution
To assign an appropriate host response to a created host group, refer to "Configuration Guide -Server
Connection-" for each OS type. The host response configures the operation mode that is appropriate for
the host. For details about the recommended patterns of host responses, refer to "Add Host Response" in
"ETERNUS Web GUI User's Guide". If an appropriate host response is not configured to the host group, the
path may not be switched correctly or the volume may not be recognized correctly.

The procedure to create an FC host group is as follows:

1 Click [Add FC/FCoE Host Group] in [Action].

The [Add FC/FCoE Host Group] screen appears.

148 Configuration Guide (Basic)


7. Host Interface Management
Add Host Groups

2 Input a host group name to be created, and select a host response to be assigned to the host group.

The main setting items are as follows.


• Host Group Setting
- Host Group Name
- Host Response

3 Register a host in a host group in the following procedures.

n When registering a host by selecting from the host list

(1) Click the [Now Connected] tab.


(2) Select a host that is to be registered from the FC host list.

The main setting item is as follows.


• Host Group Setting
Checkbox to select a host

149 Configuration Guide (Basic)


7. Host Interface Management
Add Host Groups

Caution
If the WWN is not displayed when clicking the [Rediscover] button, make sure that
there is no error in the connection environment, such as the connection between the
host and the switch, and the CA port settings of the ETERNUS DX. If there is no error in
the connection environment, contact the Support Department, or specify the WWN
manually.

(3) Click the [Add] button.

n When registering a host by manually specifying the host

(1) Click the [Manual Input] tab.


(2) Click the [Add] button.

The [Add FC/FCoE Host] screen appears.


(3) Manually specify the WWN of the host that is to be registered.

150 Configuration Guide (Basic)


7. Host Interface Management
Add Host Groups

The main setting items are as follows.


• Host Setting
WWN
(4) Click the [OK] button.
Returns to the [Manual Input] screen.
(5) Repeat Step (2) through Step (4) to set more WWNs.
(6) After adding the host is complete, click the [Add] button.

4 A confirmation screen appears. Click the [OK] button.


Registration of the FC host group starts.

5 Click the [Done] button to return to the [Host Group] screen.

Note
Click the [Continue] button to continue registering FC host groups.

151 Configuration Guide (Basic)


7. Host Interface Management
Host Affinity Creation

Host Affinity Creation


This function creates a new host affinity by specifying already registered "Host Group", "CA Port Group", and "LUN
Group".
The host accesses the volumes via the defined paths. When host affinity is configured, the volumes that are
referenced by hosts can be restricted.
The maximum number of connectable hosts (the maximum number of Host Bus Adapters [HBAs]) per port is
256 (32 for the ETERNUS DX60 S5).

Caution
A host can be a member of multiple host groups. In addition, a CA port can be a member of multiple CA
port groups. However, only one LUN group can be allocated to a combination of host and port when
configuring host affinity.

The procedure to create a host affinity when the target connection is "Host Group - CA Port Group" is as follows:

1 Click [Create Host Affinity] in [Action].

The [Create Host Affinity] screen appears.

152 Configuration Guide (Basic)


7. Host Interface Management
Host Affinity Creation

2 Click the [Browse...] button for the host group.

The [Select Host Group] screen appears.

3 Select the connection target.

n When "Host Group" is selected


Select a host group to configure a host affinity, and click the [OK] button.

The display returns to the initial screen.

n When "All" is selected


Select a host response, and then click the [OK] button.

Note
Select "All" when assigning CA port groups to any host instead of a specific host. If "All" is
selected, a host response for the CA port group must be selected. In this case, "All" is displayed
in the "All (host response name)" format.

153 Configuration Guide (Basic)


7. Host Interface Management
Host Affinity Creation

The display returns to the initial screen.

4 Click the [Browse...] button for the CA port group.

The [Select CA Port Group] screen appears.

154 Configuration Guide (Basic)


7. Host Interface Management
Host Affinity Creation

5 Select a CA port group to configure a host affinity, and click the [OK] button.

The display returns to the initial screen.

Note
• If a specific host group has been selected in the "Host Group" field, CA port groups for which the
affinity mode is "OFF" are not displayed.
• If "All" has been selected in the "Host Group" field, CA port groups with any of the following
conditions are not displayed:
- The affinity mode is "ON"
- Member CA ports that are being used in another CA port group
- CA port groups that are being used by other host affinities

155 Configuration Guide (Basic)


7. Host Interface Management
Host Affinity Creation

6 Click the [Browse...] button for the LUN group.

The [Select LUN Group] screen appears.

7 Select a LUN group to configure a host affinity, and click the [OK] button.

The display returns to the initial screen.

Note
• When "All" is selected for "Host Group", the LUN groups in which LUNs are specified from LUN#512
onward are not displayed.
• LUN groups including volumes that are used for the Storage Cluster function are not displayed.

156 Configuration Guide (Basic)


7. Host Interface Management
Host Affinity Creation

8 To edit the path between a host and a CA port, click the [Edit] button for the path to be edited.

The [Select CA Port] screen appears.

9 Select whether to enable or disable the path between a host and a CA port.

The main setting item is as follows.


• CA Port Group
Checkbox to select paths

10 Click the [OK] button.

157 Configuration Guide (Basic)


7. Host Interface Management
CA Reset Group Settings

11 Confirm the host affinity setting and the path between the host and the CA port, click the [Create] button.

12 A confirmation screen appears. Click the [OK] button.


The host affinity creation starts.

13 Click the [Done] button to return to the [Connectivity] screen.

CA Reset Group Settings


A CA reset group is a group of ports that are simultaneously released according to instructions issued from the
server.
All the ports are configured to be members of one CA reset group in the initial setting. It is not necessary to
change the setting for normal use. For details on changing the CA reset group according to instructions in
"Configuration Guide -Server Connection-", refer to "Modify CA Reset Group" in "ETERNUS Web GUI User's Guide".

158 Configuration Guide (Basic)


8. Monitoring Settings
Perform the ETERNUS DX monitoring setup if required.
For more details on the setup, refer to "ETERNUS Web GUI User's Guide".

Event Notification Setup


Select whether to report events detected in the ETERNUS DX. There are six methods for event notification: Host
Sense Key Code Qualifier, SNMP Trap, E-Mail, Syslog, REMCS, and AIS Connect.

Caution
If ETERNUS SF Storage Cruiser version 16.4 or later is used and configured to automatically obtain the
ETERNUS DX component status, event notifications by SNMP traps for some events are automatically
enabled.
The event notification items are as follows:
• Remote Path Error of no Data Transfer
• Recovery module
• Temperature restoration
• FC CA Port Link Status Changed
• iSCSI CA Port Link Status Changed
• Remote Path Recovery
• Events whose notification is enabled by default, but is disabled manually
If the ETERNUS DX is deleted from ETERNUS SF Storage Cruiser, event notifications by SNMP traps return to
the default state.
However, if the event notifications by SNMP traps are changed from the ETERNUS DX after they are
automatically changed by ETERNUS SF Storage Cruiser, the event notification setting is not returned to the
default state even if the ETERNUS DX is deleted from ETERNUS SF Storage Cruiser.
Check that there are no problems with the SNMP trap event notification setting for the ETERNUS DX.

The event notification setting is explained below.

1 On the navigation of the ETERNUS Web GUI screen, click [System].


The [System] screen appears.

2 In [Category], click [Event/Dump].


The [Event/Dump] screen appears.

3 In [Action], click [Setup Event Notification].


The [Setting based on Severity] tab screen of the [Setup Event Notification] screen appears.

159 Configuration Guide (Basic)


8. Monitoring Settings
Event Notification Setup

4 In the [Setting based on Severity] tab screen, select the required items.

5 On the screens that are displayed by clicking each level tab, select the required items.

6 Click the [Set] button to apply the specified settings.


A confirmation screen appears.

7 Click the [OK] button.


The event notification settings are applied.

8 Check the setting completion message and click the [Done] button.
The screen returns to the [Event/Dump] screen.

160 Configuration Guide (Basic)


8. Monitoring Settings
Various Notification Settings

Various Notification Settings


To monitor an ETERNUS DX, perform the required settings for device error notification.

SNMP Trap Setup


SNMP Trap can be sent to the SNMP Manager (monitoring server) when an event occurs in the ETERNUS DX.
The SNMP Trap setting is explained below.

IMPORTANT
Carefully read this manual and the manuals for the monitoring software (SNMP Manager) that is to be
used before monitoring the ETERNUS DX.

■ ETERNUS DX Settings
The SNMP Trap test setting is explained below.

1 Set up the network environment for the ETERNUS DX.


When the ETERNUS DX and the monitoring server are in different subnet environments, set the Gateway
IP address and the Allowable IP address (IP address of the monitoring server or the network address to
which the monitoring server belongs) on the [Setup Network Environment] screen of ETERNUS Web GUI.
The following procedure shows an example when selecting the [IPv4 Settings] tab.

2 Set up the SNMP environment.


(1) On the navigation of the ETERNUS Web GUI screen, click [System].
The [System] screen appears.
(2) Click [Network] in [Category].
The [Network] screen appears.

161 Configuration Guide (Basic)


8. Monitoring Settings
Various Notification Settings

(3) Click [Setup SNMP Interface] in [Action].


The [Setup SNMP Agent Basic Interface] screen appears.
(4) Select [Enable] for [SNMP Function], set the required items, and click the [Set] button.
Select the LAN port that was set up in Step 1 for "LAN Port used for SNMP".

A confirmation screen appears.


(5) Click the [OK] button.
The SNMP Agent basic settings are applied.
(6) Check the setting completion message and click the [Done] button.
The screen returns to the [Network] screen.

3 Set up the SNMP Manager.


Set up the SNMP Manager (monitoring server) that is the destination of the SNMP Trap transmission.

Note
This step is not required when ETERNUS SF Storage Cruiser is used to monitor the ETERNUS DX.

(1) Click [Setup SNMP Manager] in [Action].


The [Setup SNMP Manager] screen appears.
(2) In the manager list of the [Setup SNMP Manager] screen, click the [Add] button.
The [Manager] screen appears.

162 Configuration Guide (Basic)


8. Monitoring Settings
Various Notification Settings

(3) Enter the IP address of SNMP Manager (monitoring server) and click the [OK] button.

The screen returns to the manager list of the [Setup SNMP Manager] screen.
(4) Check the SNMP Manager that was added in Step (3) is displayed in the manager list and click the
[Set] button.
A confirmation screen appears.
(5) Click the [OK] button.
The SNMP Manager settings are applied.
(6) Check the setting completion message and click the [Done] button.
The screen returns to the [Network] screen.

4 Set up a community or a user.


Set up the community or the user that is used for SNMP Trap.

Note
• To use SNMPv1 or SNMPv2c, perform the "Setup SNMP Agent Community" settings. To use
SNMPv3, perform the "Setup SNMP Agent User" settings.
• To use ETERNUS SF Storage Cruiser for management, perform the "Setup SNMP Agent Community"
settings to use SNMPv1.

n Community setup
(1) Click [Setup SNMP Community] in [Action].
The [Setup SNMP Agent Community] screen appears.
(2) In the community list of the [Setup SNMP Agent Community] screen, click the [Add] button.

163 Configuration Guide (Basic)


8. Monitoring Settings
Various Notification Settings

(3) Enter the community name, set the required items, and click the [OK] button.

The screen returns to the community list of the [Setup SNMP Agent Community] screen.
(4) Check the community name that was set in Step (3) is added in the community list and click
the [Set] button.
A confirmation screen appears.
(5) Click the [OK] button.
The SNMP community settings are applied.
(6) Check the setting completion message and click the [Done] button.
The screen returns to the [Network] screen.

n User setup
(1) Click [Setup SNMP User] in [Action].
The [Setup SNMP Agent User] screen appears.
(2) In the user list of the [Setup SNMP Agent User] screen, click the [Add] button.

164 Configuration Guide (Basic)


8. Monitoring Settings
Various Notification Settings

(3) Enter the username, set the required items, and click the [OK] button.

The screen returns to the user list of the [Setup SNMP Agent User] screen.
(4) Check the user that was set in Step (3) is added in the user list and click the [Set] button.
A confirmation screen appears.
(5) Click the [OK] button.
The SNMP user settings are applied.
(6) Check the setting completion message and click the [Done] button.
The screen returns to the [Network] screen.

5 Trap setup
Set up the destination for sending the SNMP Trap.

Note
This step is not required when ETERNUS SF Storage Cruiser is used to monitor the ETERNUS DX.

(1) Click [Setup SNMP Trap] in [Action].


The [Setup SNMP Agent Trap] screen appears.
(2) In the trap list of the [Setup SNMP Agent Trap] screen, click the [Add] button.

165 Configuration Guide (Basic)


8. Monitoring Settings
Various Notification Settings

(3) Select the Manager No. that was set in Step 3 for [Manager No.], set the required items, and click
the [OK] button.

The screen returns to the trap list of the [Setup SNMP Agent Trap] screen.
(4) Check the trap that was set in Step (3) is added in the trap list and click the [Set] button.
A confirmation screen appears.
(5) Click the [OK] button.
The SNMP Trap settings are applied.
(6) Check the setting completion message and click the [Done] button.
The screen returns to the [Network] screen.

6 Download the MIB file.


Download the MIB file that is registered in the ETERNUS DX.
(1) Click [Download MIB File] in [Action].
The [Download MIB File] screen appears.
(2) In the [Download MIB File] screen, set the required items and click the [Download] button.

Note
Select the "The ServerView control code is added to the comment line of the MIB definition
file" checkbox when downloading the MIB file for monitoring the ETERNUS DX by ServerView.

166 Configuration Guide (Basic)


8. Monitoring Settings
Various Notification Settings

A confirmation screen appears.


(3) Click the [OK] button.
A dialog box to download the file appears.
(4) Click the [Save] button.
The MIB file is saved.
(5) Check the setting completion message and click the [Done] button.
The screen returns to the [Network] screen.

E-mail Setup
If an event occurs in the ETERNUS DX, the event information is reported to the specified e-mail address.

Note
• Up to five e-mail addresses can be set.
• Make sure to check whether the e-mail messages are received correctly after the e-mail notification
environment setup is complete.
• E-mail messages are not sent again when a communication error occurs between the ETERNUS DX and
the SMTP server.

The e-mail setting is explained below.

1 On the navigation of the ETERNUS Web GUI screen, click [System].


The [System] screen appears.

2 In [Category], click [Network].


The [Network] screen appears.

3 In [Action], click [Setup E-Mail Notification].


The [Notification E-Mail] tab screen of the [Setup E-Mail Notification] screen appears.

167 Configuration Guide (Basic)


8. Monitoring Settings
Various Notification Settings

4 In the [Notification E-Mail] tab screen, set the required items.


• Select "Yes" for "Notification E-Mail".
• Enter the destination e-mail address or addresses for the Destination E-Mail Address fields.

5 Click the [E-Mail Server Settings] tab.


The [E-Mail Server Settings] tab screen appears.

6 In the [E-Mail Server Settings] tab screen, set the required items.

7 Click the [Advanced Settings] tab.


The [Advanced Settings] tab screen appears.

8 In the [Advanced Settings] tab screen, set the required items.

Note
This item does not need to be changed from the default value for normal operation.

168 Configuration Guide (Basic)


8. Monitoring Settings
Various Notification Settings

9 Click the [Set] button to apply the specified settings.


A confirmation screen appears.

10 Click the [OK] button.


The e-mail notification settings are applied.

11 Check the setting completion message and click the [Done] button.
The screen returns to the [Network] screen.

Syslog Setup
If an event occurs in the ETERNUS DX, logs for the event can be sent to the specified Syslog server (external
server).

Note
• Up to two Syslog servers can be set.
• Make sure to check whether the Syslog server receives logs correctly after the Syslog notification
environment setup is complete.
• Logs are not sent again when a communication error occurs between the ETERNUS DX and the Syslog
server.

The Syslog setting is explained below.

1 On the navigation of the ETERNUS Web GUI screen, click [System].


The [System] screen appears.

2 In [Category], click [Network].


The [Network] screen appears.

3 In [Action], click [Setup Syslog].


The [Setup Syslog] screen appears.

169 Configuration Guide (Basic)


8. Monitoring Settings
Remote Support Setup

4 In the [Setup Syslog] screen, set the required items.


• Select "on(RFC3164)" or "on(RFC5424)" for "Send Log".

IMPORTANT
To send messages in RFC5424 format to a target Syslog server that supports RFC5424, select
"on(RFC5424)". If this is not the case, select "on(RFC3164)".

• Enter the domain name or IP address of the Syslog server in "Domain Name /IP Address".

5 Click the [Set] button.


A confirmation screen appears.

6 Click the [OK] button.


The Syslog notification settings are applied.

7 Check the setting completion message and click the [Done] button.
The screen returns to the [Network] screen.

Remote Support Setup


When using the remote support, reporting problems in the ETERNUS DX to the remote support center must be
set.

Note
Remote support allows prompt detection and resolution of trouble.

There are two ways of using the remote support function; by using AIS Connect function and by using REMCS.

170 Configuration Guide (Basic)


8. Monitoring Settings
Remote Support Setup

Caution
• Note that AIS Connect and REMCS are not available in some regions. Contact the Support Department for
details.
• AIS Connect and REMCS cannot be used at the same time. AIS Connect function can only be used when
REMCS is not specified or is stopped. When REMCS is used, suspend the REMCS function, and then
enable the AIS Connect function.

Remote Support (by AIS Connect) Setup


When using the remote support function by AIS Connect, perform the environment settings for connecting to the
remote server (AIS Connect server) in the remote support center.

IMPORTANT
• If the REMCS function is being used, temporarily stop the REMCS function.
• In the EMEIA, Central American, and Caribbean regions, the "Log Transmission" setting for the "Set E-
Mail Notification" function may be enabled ("Yes" is displayed). If this setting is enabled, disable it
(select "No").

1 On the navigation of the ETERNUS Web GUI screen, click [System].


The [System] screen appears.

2 In [Category], click [AIS Connect] in [Remote Support].


The [Remote Support] screen appears.

3 Perform the environment settings for the AIS Connect function.


(1) In [Action], click [Setup AIS Connect Environment].
The [Setup AIS Connect Environment] screen appears.
(2) Select "Enable" for "AIS Connect" and then "Country code : Country name" for "Country of Installation
(Country Code : Country Name)". Perform the other additional settings that are required.

171 Configuration Guide (Basic)


8. Monitoring Settings
Remote Support Setup

(3) Click the [Set] button.


A confirmation screen appears.
(4) Click the [OK] button.
The AIS Connect settings are applied.
(5) Check the setting completion message and click the [Done] button.
The screen display returns to the remote support screen.

4 Confirm the connection of the ETERNUS DX and the AIS Connect server in the remote support center.
(1) In [Action], click [Test Server Connectivity].
A confirmation screen appears.
(2) Click the [OK] button.
The connection with the server is checked. The result is displayed in the [Test Server Connectivity
Result] screen.
(3) Click the [Done] button.
The screen display returns to the remote support screen.

5 Send the test event to confirm that the event is reported to the AIS Connect server.
(1) In [Action], click [Send AIS Connect Test Event].
A confirmation screen appears.
(2) Click the [OK] button.
The test event is sent to the AIS Connect server. The result is displayed in the [Send AIS Connect Test
Event Result] screen.
(3) Click the [Done] button.
The screen display returns to the remote support screen.

Remote Support (by REMCS) Setup


When using the remote support function by REMCS, perform the environment settings for connecting to the
remote support center, and register the customer information to send to the remote support center.

IMPORTANT
If the AIS Connect function is being used, disable the AIS connect function and then start the remote
support (by REMCS) setup.

1 On the navigation of the ETERNUS Web GUI screen, click [System].


The [System] screen appears.

2 In [Category], click [REMCS] in [Remote Support].


The [Support Information] tab screen of the [Remote Support] screen appears.

3 In [Action], click [Setup Remote Support].


The [Setup Remote Support] screen appears.

172 Configuration Guide (Basic)


8. Monitoring Settings
Remote Support Setup

4 In the [Setup Remote Support] screen, set the items in [Customer Information File] and [Communication
Environment Information File].

5 Click the [Set] button.


A confirmation screen appears.

6 Click the [OK] button.


The remote support settings are applied.

7 Check the setting completion message and click the [Done] button.
The screen returns to the remote support screen.
The specified information is sent to the remote support center and the connection of the ETERNUS DX and
the remote support center is checked.
The connection check result is sent to the e-mail address that is set in "Result notification information".

173 Configuration Guide (Basic)


8. Monitoring Settings
Audit Log Setup

Audit Log Setup


Audit trail logs (hereinafter referred to as "audit log") that record performed operations by using the ETERNUS
DX and the system actions that are associated with these operations can be sent to the specified Syslog server
(external server).

Note
• Up to two Syslog servers can be set.
• After the environmental settings for audit logs are complete, confirm that the audit log is successfully
received on the Syslog server.
• Even if a communication error occurs between the ETERNUS DX and the Syslog server, the audit log is
not sent again.

The audit log setting is explained below.

1 On the navigation of the ETERNUS Web GUI screen, click [System].


The [System] screen appears.

2 In [Category], click [Audit Log].


The [Audit Log] screen appears.

3 If "Disable" is specified for "Audit Log", select "Enable".


(1) Click [Enable Audit Log] in [Action].
A confirmation screen appears.
(2) Click the [OK] button.
Enabling of the audit log starts.
(3) Check the setting completion message and click the [Done] button.
The screen returns to the [Audit Log] screen.

4 Specify the Syslog server to which the audit log is sent.


(1) Click [Setup Audit Log] in [Action].
The [Setup Audit Log] screen appears.
• Select "on (RFC3164)" or "on (RFC5424)" for "Send Audit Log".

IMPORTANT
To send messages in RFC5424 format to a target Syslog server that supports RFC5424, select
"on (RFC5424)". If this is not the case, select "on (RFC3164)".

• Enter the domain name or IP address of the Syslog server in "Domain Name /IP Address".

174 Configuration Guide (Basic)


8. Monitoring Settings
Monitoring Server (SNMP Manager) Settings

(2) Click the [Set] button.


A confirmation screen appears.
(3) Click the [OK] button.
Setting of the audit log starts.
(4) Check the setting completion message and click the [Done] button.
The screen returns to the [Audit Log] screen.

Monitoring Server (SNMP Manager) Settings


Install and set up the monitoring software on the server side.
Refer to the manual for the monitoring software to install and set the monitoring software.

Note
Register the file that was downloaded in Step 6 "Download the MIB file" in "SNMP Trap Setup" (page 161)
as the MIB definition file for the monitoring software.

175 Configuration Guide (Basic)


8. Monitoring Settings
Transmission Test Execution

Transmission Test Execution


For SNMP Trap notifications or e-mail notifications, perform a transmission test to make sure that event
notifications are sent normally.

SNMP Trap Test


Perform the SNMP Trap test to check that the SNMP Trap can be sent from the ETERNUS DX to the SNMP
Manager.
The procedure to send a trap test and to check the result is as follows:

1 Perform the test transmission of the SNMP Trap.


(1) On the navigation of the ETERNUS Web GUI screen, click [System].
The [System] screen appears.
(2) Click [Network] in [Category].
The [Network] screen appears.
(3) Click [Send SNMP Trap] in [Action].
The [Send SNMP Trap Test] screen appears.
(4) In the [Send SNMP Trap Test] screen, click the [Send] button.

A confirmation screen appears.


(5) Click the [OK] button.
The test transmission of the SNMP Trap is performed.
(6) Check the test transmission completion message and click the [Done] button.
The screen returns to the [Network] screen.

2 Check the result of the test transmission.


Check that the SNMP Trap is notified to the monitoring server.
For details on the messages for test transmission, refer to "Message List".

176 Configuration Guide (Basic)


8. Monitoring Settings
Transmission Test Execution

If the SNMP Manager cannot receive an SNMP test trap, check that the network has no trouble, and the
settings for the ETERNUS DX are correct.
• Is the LAN between the monitoring server and ETERNUS DX connected correctly?
Execute the "ping" command from the monitoring server, and confirm the reply from the ETERNUS DX.

IMPORTANT
When "ICMP" is disabled by the firewall settings for ETERNUS Web GUI, the "ping" command
cannot be used for confirmation. Enable "ICMP" before executing the "ping" command.

• Is the monitoring software set correctly to monitor the ETERNUS DX?


• Are the SNMP environment settings and the transmission destination for the SNMP Trap set correctly on
the ETERNUS DX?

Send Test E-mail


Perform an e-mail transmission test to check that the e-mail can be sent from the ETERNUS DX to the specified
e-mail address.
The procedure to send a test e-mail is as follows:

1 On the navigation of the ETERNUS Web GUI screen, click [System].


The [System] screen appears.

2 In [Category], click [Network].


The [Network] screen appears.

3 In [Action], click [Setup E-Mail Notification].


The [Setup E-Mail Notification] screen appears.

4 Click the [Send Test E-Mail] button.

177 Configuration Guide (Basic)


8. Monitoring Settings
Transmission Test Execution

5 Check that the test e-mail is sent to the e-mail addresses that are set.
For details on the event code and message of the test e-mail, refer to "Message List".

178 Configuration Guide (Basic)


9. Power Control Setup
Perform power control settings as required.
Power control settings must be performed if the Auto Power function (AC automatic linkage mode) is enabled,
the Power Resume function (automatic power recovery mode) is enabled, the power synchronized unit is
connected, or the Wake On LAN function is used.

Setup of the Auto Power Function and/or the Power Resume


Function
To automatically turn on the ETERNUS DX when AC power is supplied or when power is restored after a power
failure, use ETERNUS Web GUI to enable the Auto Power function and/or the Power Resume function.
• Auto Power function (AC automatic linkage mode)
When the Auto Power function is enabled, the ETERNUS DX is automatically turned on when AC power is
supplied.
The Auto Power function is disabled for the factory default setting.
• Power Resume function (automatic power recovery mode)
When the Power Resume function is enabled, the ETERNUS DX is automatically turned on when the power
supply is restored after a power failure.
The Power Resume function is disabled for the factory default setting.
Table 9 shows how the ETERNUS DX operates when the Auto Power function and the Power Resume function are
enabled or disabled.

Table 9 ETERNUS DX Operation according to the Settings of the Auto Power Function and the Power Resume
Function
Settings for the power control functions How the ETERNUS DX operates

Auto Power function is disabled The ETERNUS DX is not automatically turned on even when AC power is supplied
Power Resume function is disabled or when power is restored after a power failure.

Auto Power function is enabled The ETERNUS DX is automatically turned on when AC power is supplied.
Power Resume function is disabled The ETERNUS DX is not turned on even when power is restored after a power
failure.

Auto Power function is disabled The ETERNUS DX is not turned on automatically even when AC power is supplied.
Power Resume function is enabled The ETERNUS DX is automatically turned on when power is restored after a power
failure.

Auto Power function is enabled The ETERNUS DX is automatically turned on when AC power is supplied and when
Power Resume function is enabled power is restored after a power failure.

The procedure to enable the Auto Power function and the Power Resume function is described below.

1 On the navigation of the ETERNUS Web GUI screen, click [System].


The [System] screen appears.

2 Click [System Settings] in [Category].


The [System Settings] screen appears.

3 Click [Setup Power Management] in [Action].


The [Setup Power Management] screen appears.

179 Configuration Guide (Basic)


9. Power Control Setup
Connection Setup for Power Synchronized Units

4 In the [Setup Power Management] screen, select [Enable] for [Auto Power], [Power Resume], or both.

5 Click the [Set] button.


A confirmation screen appears.

6 Click the [OK] button.


The Auto Power function and/or the Power Resume function setting is applied.

7 Check the setting completion message and click the [Done] button.
The screen returns to the [System Settings] screen.

Connection Setup for Power Synchronized Units


Refer to "Configuration Guide (Power Synchronized Unit)" for the required settings to use power control by
connecting power synchronized units to an ETERNUS DX.

180 Configuration Guide (Basic)


9. Power Control Setup
Wake On LAN Settings

Wake On LAN Settings


A network environment needs to be set to receive magic packets that are used by Wake On LAN for the ETERNUS
DX.
The procedure to set Wake On LAN is as follows:

1 On the navigation of the ETERNUS Web GUI screen, click [System].


The [System] screen appears.

2 In [Category], click [Network].


The [Network] screen appears.

3 In [Action], click [Setup Network].


The [Setup Network Environment] screen appears.

4 In the [Setup Network Environment] screen, select [Enable] for [Wake on LAN].
• For operations with cluster connections, set the IP address of the Slave CM for the "Slave IP Address" of
the MNT port.
• To control power supply with servers in a network to which the ETERNUS DX does not belong, set
"Gateway" and specify the server IP address or the network address in "Allowable IP Address".

5 Click the [Set] button.


A confirmation screen appears.

6 Click the [OK] button.


The network environment settings are applied.

7 Check the setting completion message and click the [Done] button.
The screen returns to the [System Settings] screen.

181 Configuration Guide (Basic)


10. System Status Check
Check the status of the ETERNUS DX on the ETERNUS Web GUI screen or ETERNUS CLI.

Checking the Component Status


The status of the ETERNUS DX can be checked by general status in the upper left of the ETERNUS Web GUI screen.
When the general status image is " ", the ETERNUS DX is in normal status. When the general status
image is other than " " (" ", " ", etc.), an abnormality has been detected in the ETERNUS
DX. Check the status of each component on the [Storage] screen.
Display example (ETERNUS DX500 S5)

If there is a component in Warning or Error status, contact your sales representative or maintenance engineer.

182 Configuration Guide (Basic)


10. System Status Check
Checking the RAID Groups

Checking the RAID Groups


On the [RAID Group Details] screen of ETERNUS Web GUI, the status of RAID groups that you have created is
displayed. Check if RAID configuration is set correctly.
To display the [RAID Group Details] screen, click the [RAID Group] tab on the navigation of the ETERNUS Web GUI
screen. In the [RAID Group (Basic Information)] screen that appears, select which RAID group to check the
information for and click the No. or name of this RAID group.
Display example (ETERNUS DX500 S5)

Checking the Volumes


On the [Volume Details] screen of ETERNUS Web GUI, the status of volumes that you have created is displayed.
Check if volumes are set correctly.
To display the [Volume Details] screen, click the [Volume] tab on the navigation of the ETERNUS Web GUI
screen. In the [Volume (Basic Information)] screen that appears, select which volume to check the information
for and click the No. or name of this volume.
Display example (ETERNUS DX500 S5)

183 Configuration Guide (Basic)


10. System Status Check
Checking the LUNs

Checking the LUNs


Check the LUN status from the server.
This section describes the check procedure using the ETERNUS Multipath Driver.
Click the [Start] button for Windows, expand [ETERNUS Multipath Driver] from [All Programs], and open
[ETERNUS Multipath Manager]. Check that the LUN status is normal (that the signal icon is blue).

184 Configuration Guide (Basic)


10. System Status Check
Powering Off

Powering Off
To turn off the ETERNUS DX, perform one of the procedures below.
• Via the power switch
Press the Power switch to turn off the ETERNUS DX.
• Via ETERNUS Web GUI or ETERNUS CLI
Use ETERNUS Web GUI or ETERNUS CLI to turn off the ETERNUS DX.
The following methods can be used to turn off the power by linking with the server.
• Via the power synchronized unit
Use the power synchronized unit to turn off the ETERNUS DX.

IMPORTANT
• When the ETERNUS DX is turned off, the power shuts off after the data in the cache memory is written to
the drives. As a result, it may take the following time for the power supply to be completely turned off.

Table 10 Time Required to Turn the Power Off


Deduplication/ Deduplication/
VLAN/Bonding maximum
Model Compression function Compression function Unified configuration (*1)
configuration
is disabled is enabled

DX60 S5 Approx. 8 minutes — — —


(max. 10 minutes)

DX100 S5 Approx. 8 minutes — Approx. 13 minutes (max. Approx. 20 minutes (max.


(max. 10 minutes) 25 minutes) 25 minutes)

DX200 S5 Approx. 8 minutes Approx. 12 minutes Approx. 13 minutes (max. Approx. 20 minutes (max.
(max. 10 minutes) (max. 14 minutes) 25 minutes) 25 minutes)

DX500 S5 Approx. 10 minutes Approx. 18 minutes Approx. 15 minutes (max. Approx. 20 minutes (max.
(max. 15 minutes) (max. 23 minutes) 25 minutes) 25 minutes)

DX600 S5 Approx. 10 minutes Approx. 19 minutes Approx. 15 minutes (max. Approx. 20 minutes (max.
(max. 15 minutes) (max. 24 minutes) 25 minutes) 25 minutes)

DX900 S5 Approx. 10 minutes Approx. 11 minutes — —


(*2) (max. 20 minutes) (max. 21 minutes)

*1: The time required to turn the power on for the Unified configuration depends on the NAS configuration (or the number of
shared folders and the number of VLAN/Bonding configurations).
*2: The ETERNUS DX900 S5 supports the Compression function only.

• Do not turn off the power of the ETERNUS DX and the network devices that connect the ETERNUS DX to a
server while the server is operating. This may result in the loss of data or prevent data from being saved
in the ETERNUS DX.
• When using a power synchronized unit for power control, turn off the power of the ETERNUS DX via the
power synchronized unit. When a power synchronized unit is connected, the power of the ETERNUS DX is
automatically turned on because the power synchronization function is activated.

• If the REMOTE LED ( ) on the ETERNUS DX is green, turn off the ETERNUS DX by linking with the
server. Pressing the Power switch does not turn off the ETERNUS DX.
• To turn off the ETERNUS DX, use the Power switch, a power synchronized unit, ETERNUS Web GUI, or
ETERNUS CLI. If any other method is used to turn off the ETERNUS DX, the replacement time for the
battery is sped up significantly because the battery continues to charge and discharge.

185 Configuration Guide (Basic)


10. System Status Check
Powering Off

This section explains how to use the Power switch and the power synchronization unit to turn off the ETERNUS
DX.
For other procedures, refer to the related manuals.

■ When Controlling by the Power Switch


This section explains how to use the Power switch to turn off the ETERNUS DX.

1 Press the Power switch of the controller enclosure or the frontend enclosure for four seconds or more.

Power switch
Power switch

Controller enclosure

ETERNUS DX60 S5/DX100 S5/DX200 S5 ETERNUS DX500 S5/DX600 S5

Power switch

Frontend enclosure

ETERNUS DX900 S5

The READY LED ( ) on the controller enclosure or the frontend enclosure is turned off.

IMPORTANT
• After power-off, wait for about one minute before turning power on again.

• If the Power switch is pressed again between the time of the READY LED ( ) turning off and the
POWER LED ( ) turning off, the ETERNUS DX power may turn on.

2 The power of the ETERNUS DX is disconnected.


When the power is disconnected, the POWER LED ( or ) of each enclosure is turned off.

■ When a Power Synchronized Unit Is Used


If the server is turned off, the ETERNUS DX is also turned off.

186 Configuration Guide (Basic)


11. Solution Configuration
This chapter describes the optimum solutions provided by the ETERNUS DX linking with software programs.

Business Continuity
Remote Copy Operations for the Storage System (Copies between ETERNUS DX Storage
Systems)

■ Solution Overview
The ETERNUS DX can perform real time data transfers from the operation site to a remote site. Even if an error
occurs in the operation site, operations can continue by switching operation from the operation site to the
backup site. Data transfers to a remote site occur only between storage systems, not through servers, which
reduces the load on the server.
Support for multiple transfer methods also enables flexible backup systems to be configured according to the
operation environment.

Figure 15 Solution — Continuous Business (Copy between ETERNUS DX Storage Systems)


Operation site Backup site

ETERNUS SF ETERNUS SF
AdvancedCopy Manager AdvancedCopy Manager

Business server Standby

SAN Gateway Gateway SAN

CA/RA CA/RA W AN CA/RA CA/RA

ETERNUS DX Operation management ETERNUS DX


server

■ Configuration Procedure
Configure the system to perform Remote Advanced Copying (REC) by using ETERNUS SF AdvancedCopy Manager
(ACM).
Operations are performed from the business server as an ETERNUS SF AdvancedCopy Manager agent and from
the operation management server as an ETERNUS SF AdvancedCopy Manager manager.
Register the business server (ETERNUS SF AdvancedCopy Manager agent) and the business volumes that are to
be backed up in the operation management server (ETERNUS SF AdvancedCopy Manager manager).
REC related settings and connection path settings must be performed in the ETERNUS DX.

● Required Environment
ETERNUS SF AdvancedCopy Manager agent and a gateway device (that connects the storage systems) must
be installed in each operation site and backup site. ETERNUS SF AdvancedCopy Manager manager must be
installed in either of the sites (one ETERNUS SF AdvancedCopy Manager manager can manage the ETERNUS
SF AdvancedCopy Manager agents of both sites).

187 Configuration Guide (Basic)


11. Solution Configuration
Business Continuity

● Configuration Procedure
• Settings for the ETERNUS DX
Register the following information with ETERNUS Web GUI.
- Host interface settings
Set the port mode of the host interface to RA or CA/RA.
- Copy table size settings
Set a memory area to manage the REC progress.
- Copy path settings
Set the information of the copy paths between the storage systems to perform an REC. Confirm that the
storage systems can communicate with each other after setting of the copy paths is complete.
- REC Buffer settings
This setting is required when an REC is performed in the Consistency mode. The Consistency mode
guarantees the order of data transfers to the connection destination storage system for all of the
specified REC sessions.
- REC Disk Buffer registration
Set the REC Disk Buffer when REC Buffer capacity is to be expanded.
• Settings for ETERNUS SF AdvancedCopy Manager
Register the following information in the operation management server (ETERNUS SF AdvancedCopy
Manager).
- Registration of the ETERNUS SF AdvancedCopy Manger license
Register a license key via the ETERNUS SF Web Console or ETERNUS SF CLI.
- Business server registration
Register the server in which the ETERNUS SF AdvancedCopy Manager agent is running as the business
server in the operation management server.
- Registration of the device information in the server that is the management target
Register the device information in the server that is the management target to the operation
management server.
- Settings for replication
Register the replication source volumes and the replication destination volumes.
For more details on the settings for ETERNUS SF AdvancedCopy Manager, refer to "ETERNUS SF
AdvancedCopy Manager Operation Guide".

188 Configuration Guide (Basic)


11. Solution Configuration
Business Continuity

Automatic Switching Operation of the Storage Systems (Storage Cluster)

■ Solution Overview
Since data equivalence is maintained between two ETERNUS DX storage systems, even when one of the
ETERNUS DX storage systems fails, operation can continue by switching the I/O access destination to the other
ETERNUS DX either manually or automatically (automatic failover).

Figure 16 Solution — Continuous Business (Storage Cluster)


Normal operation When a failure occurs

Business server Business server

Operations can continue


by switching to
the Secondary storage
FC FC FC FC

Switch SAN Switch Switch SAN Switch

Active Standby Standby Active

Failover
CA CA CA CA CA CA CA CA

Operation Mirrored Operation Mirrored


data data data data
Replication
Operation Mirrored Failure Operation Mirrored
data data data data

ETERNUS DX ETERNUS DX ETERNUS DX ETERNUS DX


(Primary storage) (Secondary storage) (Primary storage) (Secondary storage)

Storage Cluster Storage Cluster


controller controller
Monitor Monitor Monitor Monitor

The Storage Cluster controller


ETERNUS SF detects a failure ETERNUS SF
Storage Cruiser in the Primary storage Storage Cruiser

■ Configuration Procedure
Connect business servers to the ETERNUS DX storage systems (Primary and Secondary storage systems) via
switches, and then connect the management server (ETERNUS SF Storage Cruiser) to the ETERNUS DX storage
systems via LANs.
To perform automatic failover, connect the Storage Cluster controller to ETERNUS DX storage systems (Primary
and Secondary storage systems) via the LAN in order to detect trouble in the ETERNUS DX storage systems.
To configure Storage Cluster, perform the settings with ETERNUS SF Storage Cruiser.

● Required Environment
Two ETERNUS DX storage systems are required.
To use Storage Cluster, the ETERNUS SF Storage Cruiser Storage Cluster option is necessary.
A Storage Cluster controller is required to perform automatic failover.

● Configuration Procedure
Use ETERNUS SF Storage Cruiser to perform the following settings.
• Registration of the ETERNUS DX
• License Registration
• Registration and configuration for servers and FC switches

189 Configuration Guide (Basic)


11. Solution Configuration
Storage Optimization

• Storage Cluster configuration settings


• Operation volume preparation
• Access path settings
• Storage Cluster controller settings (when performing automatic failover)
For more details on the settings for ETERNUS SF Storage Cruiser, refer to "ETERNUS SF Storage Cruiser
Operation Guide".

Storage Optimization
Automated Storage Tiering

■ Solution Overview
Automated Storage Tiering is a function that detects frequently accessed data by monitoring data access to the
storage, and redistributes data between drives of various types according to the policy that is set.
By storing the less frequently accessed data to cost effective Nearline SAS disks with a large capacity, storage
cost can be reduced. By storing the frequently accessed data to high performance SSDs, response time are
reduced and performance is improved.
In addition, by automating operation, data management hours and management costs can be reduced.

Figure 17 Solution — Automated Storage Tiering


Operation management server ETERNUS DX

Monitors access frequency and


ETERNUS SF automatically redistributes data to the optimal layer
Storage Cruiser

Access frequency
Automated Storage Tiering
High
SSD Reduce
Fastest response time

SAS disk
Fast

Nearline SAS disk


High capacity, cost effective

Reduce data
storage costs

Low

Operation volume

190 Configuration Guide (Basic)


11. Solution Configuration
Storage Optimization

■ Configuration Procedure
Automated Storage Tiering can be achieved by using the Flexible Tier function of the ETERNUS DX and the
function of ETERNUS SF Storage Cruiser.

● Required Environment
For single tier pools, ETERNUS SF Storage Cruiser must be installed. For two or three tier pools, the ETERNUS
SF Storage Cruiser Optimization option must be installed.

● Configuration Procedure
Set the tiering policy and the virtual storage pool in the operation management server (ETERNUS SF Storage
Cruiser).
For details on the settings, refer to "ETERNUS SF Storage Cruiser Operation Guide for Optimization Option".

Performance/Tuning

■ Solution Overview
The performance of existing systems may be affected when the number of servers that access the ETERNUS DX
increases due to increased operations. The process performance that the user sets as the target value can be
automatically adjusted by using ETERNUS SF Storage Cruiser to automate Quality of Service (QoS). This
guarantees the bandwidth for a server according to the operation priority to reduce the effect on one server from
another server, which results in the performance of a server with high priority and important operations to be
guaranteed.
Efficient operation can be achieved when the response performance of different operations are guaranteed in
different time periods. Examples of this include when the Exchange server and backup applications exist
together, and the Exchange environment is given priority during daytime and backup application operations are
given priority during nighttime.

191 Configuration Guide (Basic)


11. Solution Configuration
Storage Optimization

Figure 18 Solution — Performance/Tuning

Server A with low Server B with low Server C with high


priority operations priority operations priority operations

The bandwidth of the server with high


priority operations is secured by
reducing the I/Os of the servers with
low priority operations.

QoS automation

ETERNUS SF Improved and stabilized


Storage Cruiser responses for prioritized
operations

Response time (ms)


Extreme Cache Pool

SSD
Operation C Fastest

SAS disk
Fast

Nearline SAS disk


Operation A High capacity, cost effective

ETERNUS DX

■ Configuration Procedure
To automate QoS, install ETERNUS SF Storage Cruiser and the ETERNUS SF Storage Cruiser QoS Management
option on the operation management server.

● Required Environment
To automate QoS, the ETERNUS SF Storage Cruiser QoS Management option must be installed.

● Configuration Procedure
Set the tiering policy and the virtual storage pool in the operation management server (ETERNUS SF Storage
Cruiser).
For details on the settings, refer to "ETERNUS SF Storage Cruiser Operation Guide for Optimization Option".

192 Configuration Guide (Basic)


11. Solution Configuration
Green

Green
■ Solution Overview
Power consumption can be reduced by stopping disk motors when they are not being used. Making power
consumption more efficient reduces the cost of electricity, noise emissions, and CO2 emissions.
If the backup time period is predetermined, power saving operations can be implemented effectively by setting
the Eco-mode schedule for backing up disk drives to only activate the disks when required. The disks motor or
the disks power can be turned on and off according to the backup operation state using ETERNUS SF
AdvancedCopy Manager.
The graphical display when ETERNUS SF Storage Cruiser is used makes it easy to understand changes in power
consumption and in temperature as well as check the effect of power saving operations and the effect of air
conditioning around the ETERNUS DX. This statistical data can be output to a file so that it can be used when
planning which power supply equipment and air conditioning equipment should be used by monitoring the
degree of changes in power consumption and temperature.

Figure 19 Solution — Green

During operation Backup volume


operation
Business drives
12

PM
Off
Backup drives

Stopped Stopped Stopped Stopped Stopped

During backup Operates


for only four hours
Business drives
12
On
AM
Off 4
Backup drives

ETERNUS DX

Server

Collects power consumption


and temperature data
for each storage system

ETERNUS SF
Storage Cruiser

193 Configuration Guide (Basic)


11. Solution Configuration
Green

■ Configuration Procedure
Perform the required settings for Eco-mode. These settings can be performed with either ETERNUS SF Storage
Cruiser or ETERNUS Web GUI.
To set the visualization of power consumption and temperature, use ETERNUS SF Storage Cruiser. ETERNUS SF
Storage Cruiser obtains power consumption of the ETERNUS DX for "power consumption" and ambient
temperature (intake air temperature for the fans) for "temperature".

● Required Environment
ETERNUS SF Storage Cruiser is required to visualize (graphically display) the power consumption and
temperature.

● Configuration Procedure
Eco-mode
Perform the following settings with the operation management server (ETERNUS SF Storage Cruiser) or
ETERNUS Web GUI:
• Eco-mode setup
Enable the Eco-mode for the ETERNUS DX.
• Eco-mode schedule setup
Set the schedule to apply Eco-mode. Register the time period to turn on the disk motors or turn on the
disk power for backups as well as the RAID group that contains these target disks.
Visualization of the power consumption and the temperature
Register the ETERNUS DX storage systems that are the targets for performance management in the
operation management server (ETERNUS SF Storage Cruiser).
For more details on the settings for ETERNUS SF Storage Cruiser, refer to "ETERNUS SF Storage Cruiser
Operation Guide".

194 Configuration Guide (Basic)


11. Solution Configuration
Virtualization Platform

Virtualization Platform
By linking virtualization software, the entire status of a system that has an ETERNUS DX can be understood by
using the management tool for the server virtualization environment. This central administrative control of the
virtual environment enables operations to be improved and optimized.

Oracle VM Linkage

■ Solution Overview
The Oracle VM Storage Connect framework supports creation, deletion, and expansion of Logical Unit Number
(LUN) and snapshot native storage service, so that Oracle VM Manager can directly use the resources and
functions of the storage system existing in the Oracle VM environment.

Figure 20 Solution — Virtualization Platform (Oracle VM Linkage)

App App App App App App

OS OS OS OS OS OS

Oracle VM
Oracle VM Oracle VM
Manager
ETERNUS ETERNUS
Oracle VM Storage Oracle VM Storage
Connect Plug-in Connect Plug-in
Administrator Management server

Business server Business server

SAN

ETERNUS DX

■ Configuration Procedure
Install any plug-ins that are required for Oracle VM linkage and perform the necessary settings.

● Required Environment
For linkage with Oracle VM Manager, ETERNUS Oracle VM Storage Connect Plug-in is required. An Advanced
Copy Feature license is also required.

● Configuration Procedure
Install ETERNUS Oracle VM Storage Connect Plug-in in the Oracle VM Server. For details on ETERNUS Oracle
VM Storage Connect Plug-in installation, refer to "ETERNUS Oracle VM Storage Connect Plug-in User's Guide".
• Settings for the ETERNUS DX
Use ETERNUS Web GUI or ETERNUS CLI to perform the following preliminary settings.
- Registration of a user account with the Software role
- RAID group and Thin Provisioning Pool creation
- Settings of a LAN for operation management (such as the firewall settings and the SSH connection
settings)
• SAN connection
Perform FC switch zoning settings to connect the Oracle VM Server and the ETERNUS DX with FC switches.

195 Configuration Guide (Basic)


11. Solution Configuration
Virtualization Platform

• Registration of the ETERNUS DX


Discover a SAN server with Oracle VM Manager and register the ETERNUS DX. For details on operating
Oracle VM Manager, refer to "Oracle VM User's Guide".

VMware Linkage

■ Solution Overview
Information on the ETERNUS DX can be checked from the vSphere Web Client by expanding the user interface for
VMware vSphere Web Client. The VMware administrator can grasp the physical and virtual mapping related to
virtual machine, datastore, and host system, allowing integrated management of the infrastructure under a
virtual environment. In addition, installation of vSphere Storage APIs for Storage Awareness (VASA) can enhance
the VMware storage management function.

Figure 21 Solution — Virtualization Platform (VMware Linkage)

App App App App App App

OS OS OS OS OS OS
VM management server
VMware VMware

VMware
VMware vSphere vCenter Server
Web Client
SAN
Web Client Server

Storage
management
server

ETERNUS VASA
Provider
• Status check of the ETERNUS DX
• Profile-Driven Storage ETERNUS SF
• Storage DRS Storage Cruiser

ETERNUS DX

■ Configuration Procedure
Install any plug-ins that are required for VMware linkage and perform the necessary settings.

● Required Environment
For linkage with vSphere Web Client, ETERNUS vCenter Plug-in is required.
For linkage with VASA, ETERNUS SF Storage Cruiser and ETERNUS VASA Provider are required.

● Configuration Procedure
vCenter
Install ETERNUS vCenter Plug-in in a Windows server where VMware Web Client Server is installed.
• Server-side settings
Install ETERNUS vCenter Plug-in and then register the ETERNUS DX as a management target device.
• Settings for the ETERNUS DX
Enable SSH connections in the firewall settings of the network settings in ETERNUS Web GUI.
For mode details on the settings for ETERNUS vCenter Plug-in, refer to "ETERNUS vCenter Plug-in User's
Guide".

196 Configuration Guide (Basic)


11. Solution Configuration
Virtualization Platform

VASA Provider
Install ETERNUS VASA Provider in the storage management server in which ETERNUS SF Storage Cruiser is
operating.
• Settings for ETERNUS VASA Provider
Install ETERNUS VASA Provider in the storage management server.
Perform the settings that are related to ETERNUS VASA Provider in the vCenter Server after installation.
• Settings for ETERNUS SF Storage Cruiser
Before starting the ETERNUS VASA Provider service, register ESXi Server and the ETERNUS DX that is to be
monitored in ETERNUS SF Storage Cruiser.
Update the configuration file and enable linkage with the device event information to apply the ETERNUS
VASA Provider settings.
For more details on the settings for ETERNUS VASA Provider, refer to "ETERNUS VASA Provider User's Guide".
For more details on the settings for ETERNUS SF Storage Cruiser, refer to "ETERNUS SF Web Console Manual"
and "ETERNUS SF Storage Cruiser Operation Guide".

197 Configuration Guide (Basic)


11. Solution Configuration
Virtualization Platform

Veeam Storage Integration


Veeam Storage Integration is available for the ETERNUS DX.

■ Solution Overview
The ETERNUS DX improves the operability and efficiency of the backups in virtual environments (VMware) using
Veeam Storage Integration to link with Veeam Backup & Replication provided by Veeam Software.

Figure 22 Solution — Virtualization Platform (Veeam Storage Integration)

Veeam backup server Backup repositories


- Job management - Data transfer
- Component management - Data storage

FUJITSU Plug-In for Veeam


Storage device where
Backup & Replication the backup data is stored

LAN

Server App App App


Data
OS OS OS

VMware

SAN FC, iSCSI

Data Backup proxies


- Backup and restore
of virtual machines
- Data transfer

ETERNUS DX

■ Configuration Procedure
The operability and efficiency of Virtual Machine backups in virtual environments (VMware) are improved by
using the ETERNUS DX storage snapshot integration with Veeam Backup & Replication provided by Veeam
Software.

198 Configuration Guide (Basic)


11. Solution Configuration
Virtualization Platform

● Configuration Procedure

Caution
• To use Veeam Storage Integration, set Advanced Copy.
For information on how to set Advanced Copy, refer to "Settings for the Advanced Copy Environment"
in "Configuration Guide (Web GUI)".
• iSCSI and FC host interfaces are supported in Veeam Storage Integration for the connection between
backup proxies and the ETERNUS DX.
• SnapOPC+ is used for Veeam Storage Integration.
Thin Provisioning Volumes (TPVs) or Flexible Tier Volumes (FTVs) are used as SnapOPC+ copy
destination volumes.
Configure an appropriate maximum pool capacity for the Thin Provisioning function by taking the
total capacity of volumes used for Veeam Storage Integration and the number of snapshot
generations into consideration.
For more details about the maximum pool capacity setting, refer to "Thin Provisioning Pool
Management" in "ETERNUS Web GUI User's Guide".

Guidelines for the maximum pool capacity for the Thin Provisioning function:
Maximum pool capacity ³ total capacity of TPVs and FTVs + total capacity of volumes for Veeam
Storage Integration ´ (number of snapshot generations + 1)
• To connect a Backup Proxy with the ETERNUS DX via an FC, the host affinity settings must be
configured for the Backup Proxy using ETERNUS CLI. For more details, refer to "ETERNUS CLI User's
Guide".
• For a restore process using a host that does not have any LUNs attached, host affinity settings for
the host must be configured in advance. Refer to "ETERNUS CLI User's Guide" for more details about
host affinity settings.

Note
• Veeam Storage Integration supports the following volumes.

Table 11 Volume Types That Can Be Used with Veeam Storage Integration
Volume type Copy source Copy destination

Standard ¡ ´

WSV ¡ ´

TPV ¡ ¡
FTV (*1) ¡ ¡
SDV ´ ´

SDPV ´ ´

¡: Supported ´: Not supported


*1: This is not supported in the ETERNUS DX60 S5.

• Copy destination TPVs/FTVs are automatically created when snapshots are created with Veeam
Backup & Replication.

• Configuration of Veeam Storage Integration environment


Connect the ETERNUS DX, the backup proxies, the Veeam backup server, and the backup repositories
properly.

199 Configuration Guide (Basic)


11. Solution Configuration
Virtualization Platform

For details, refer to the Veeam Backup & Replication manual that is provided by Veeam Software.
• Settings for the ETERNUS DX
Obtain and register a Veeam Storage Integration license.
- A Veeam Storage Integration license and FUJITSU Plug-In for Veeam Backup & Replication (*1) can be
obtained from the following website.
*1: FUJITSU Plug-In for Veeam Backup & Replication is used with the Veeam backup server settings.
https://www.fujitsu.com/global/support/products/computing/storage/download/veeam/

Note
The serial number of the ETERNUS DX is required to obtain a Veeam Storage Integration license
and FUJITSU Plug-In for Veeam Backup & Replication.

- Register the Veeam Storage Integration license.


Refer to "License Registration" in "Operation Guide (Basic)" for details.
- If the backup proxy is connected to the ETERNUS DX via an FC, configure the host affinity settings for the
backup proxy using ETERNUS CLI.
For the host affinity settings of the backup proxy, refer to "ETERNUS CLI User's Guide".
• Installation of FUJITSU Plug-In for Veeam Backup & Replication
Install FUJITSU Plug-In for Veeam Backup & Replication to Veeam Backup & Replication.
For details about how to install FUJITSU Plug-In for Veeam Backup & Replication and use Veeam Backup &
Replication, refer to the Veeam Backup & Replication manual that is provided by Veeam Software.

Caution
• If a volume has several snapshot generations and these snapshots have been created with different
resolutions, only the oldest snapshot generation can be deleted.
• The following volumes cannot be managed or operated by Veeam Backup & Replication:
- Volumes in the Secondary storage used for the Storage Cluster function (note that these volumes
are not supported in the ETERNUS DX60 S5)
- Virtual Volumes (VVOLs) (note that VVOLs are not supported in the ETERNUS DX60 S5)
- Volumes with SnapOPC or EC Advanced Copy sessions
- Volumes with SnapOPC+ sessions created by ETERNUS SF AdvancedCopy Manager
• Although the volumes in the Primary storage used for the Storage Cluster function can be managed
by Veeam Backup & Replication, note the following points.
- If the Storage Cluster function's failover is performed, the Veeam Backup & Replication job or
operation may fail. After a failback, re-perform the job or operation that failed.
- Failover cannot be performed while Instant VM Recovery or SureBackup is running.
• Veeam Backup & Replication jobs or operations may fail during a firmware upgrade, a RAID
migration, a Thin Provisioning Volume balancing, or a Flexible Tier Pool balancing.
• It is not recommended to use multiple Veeam Backup & Replication for managing a single ETERNUS
DX.
In such configuration, an error might occur at the jobs that are in conflict with each other when
being executed from multiple Veeam Backup & Replication.

200 Configuration Guide (Basic)


11. Solution Configuration
Virtualization Platform

Microsoft Linkage

■ Solution Overview
By linking with Microsoft System Center Virtual Machine Manager (SCVMM), the resources and functions of the
ETERNUS DX can be controlled directly from the management console of System Center 2012 or later.

Figure 23 Solution — Virtualization Platform (Microsoft Linkage)

SCVMM 2012
management environment

App App App App App App

OS OS OS OS OS OS
SCVMM 2012
Hyper-V Hyper-V
management console

SMI-S
Management server SAN
Administrator

ETERNUS DX

■ Configuration Procedure
Install any plug-ins that are required for function linkage and perform the necessary settings.

● Required Environment
For linkage with System Center 2012, no plug-ins are required.

● Configuration Procedure
SCVMM2012
Use ETERNUS Web GUI to enable the SMI-S settings in the ETERNUS DX.
If the management console for SCVMM2012 uses a different subnet, add the subnet to [Allowed IP List] in
[Set Network Environment].
When Windows Server 2012 or later is installed in the Hyper-V server, the ODX function is available for data
copying. Create ODX volumes after enabling the ODX settings for the Advanced Copy function in the
ETERNUS DX with ETERNUS Web GUI.
For details on the SCVMM2012 settings, refer to the manual of the SCVMM2012.

201 Configuration Guide (Basic)


11. Solution Configuration
Security

Security

■ Solution Overview
Unauthorized access can be monitored by using the ETERNUS DX's audit log collection and transfer function. Use
acquired audit log information as audit trail information to monitor and track suspicious operations and access.
Centralized administrative control of SED authentication keys in an external server can be performed by linking
with the key server. Even if a data drive in the ETERNUS DX is stolen, data leakage can be prevented by safely
storing the authentication key. Automatic updating of the authentication key on a periodic basis also enhances
the security of the entire system.

Audit logs are used


Log in Information such as - as audit information when
the storage system name, system audits are performed
↓ - to monitor and report the
Change settings the user information, Syslog server
storage system status
↓ the process time,
System administrator
Log out the process details,
and the process results
Auditor

Audit log

Management LAN

ETERNUS DX

Key groups
ETERNUS SF KM

SED SED SED SED Key server

RAID group #0

SED SED SED SED

RAID group #1 The authentication key is


updated periodically according
to the specified schedule

■ Configuration Procedure
Use the ETERNUS DX to enable the audit log transmission function and to register the Syslog server as the
destination to which audit logs are sent.
When key management server linkage is used, set up SED key management in the operation management
server (ETERNUS SF KM). Use the ETERNUS DX to create a key group and to register the key server. Keys are
created in the operation management server. The ETERNUS DX requests the key to be extracted from the
operation management server or requests the key to be updated when required.

● Required Environment
A Syslog server is required for the destination for the transmission of the audit log that is collected.
Note that ETERNUS SF KM is required when linking with the key management server.

202 Configuration Guide (Basic)


11. Solution Configuration
Security

● Configuration Procedure
Audit log transmission
Perform the following settings with the ETERNUS DX:
• Audit log setup
Use ETERNUS Web GUI to specify the message format of audit logs that are sent and specify the domain
name or the IP address for the Syslog server that receives these logs.
For details on the settings for a Syslog server that receives audit logs, refer to the manuals of the Syslog
management software.
Key management server linkage
• Settings for the ETERNUS DX
Register the following information with ETERNUS Web GUI.
- SED authentication key registration
Register the key that is managed in the ETERNUS DX (common key).
- Self-signed SSL certificate creation
Create a self-signed SSL certificate as the SSL certificate of the ETERNUS DX to establish communication
between the ETERNUS DX and the key server.
- Key management device name setup
Specify the name (machine ID) of the ETERNUS DX that is used for key management.
- Key server setup
Specify the FQDN or the IP address of the key server that is linked.
- Key group creation
Create a key group to register the RAID groups that use the same key.
- SSL/KMIP server certificate import
Register the SSL/KMIP server-side certificate that is exported from the key server in the ETERNUS DX.
- SED authentication key update
Obtain the key that is set to the key group from the server.
- Creating the key group
Register the RAID groups that use the same key in the key group.
• Settings for ETERNUS SF KM
Register the following information in the key server (ETERNUS SF KM):
- SSL certification registration
Perform the setting to use the self-signed SSL certificate of the ETERNUS DX in order to provide the key.
- Network setting
Add the IP address and the host name of the ETERNUS DX in the hosts file.
- Specifying the ETERNUS DX that is the target for management
Specify the group name that is registered in the ETERNUS DX and the name (machine ID) of the
ETERNUS DX that is set for key management.
To complete the settings for the ETERNUS DX and ETERNUS SF KM, the certificate for the ETERNUS DX must
be registered in ETERNUS SF KM. The certificate for ETERNUS SF KM must also be registered in the ETERNUS
DX. For details on the setting procedures and setting items, refer to "ETERNUS SF KM Installation Guide".

203 Configuration Guide (Basic)


A. Component Names
This appendix provides the component names of the ETERNUS DX.

Frontend Enclosures (ETERNUS DX900 S5)


The frontend enclosure has service controllers (SVCs), a system operation panel, and fan units in the front, and
frontend routers (FRTs) and power supply units in the rear.

Front
This section provides the names of the components on the front of a frontend enclosure.

Figure 24 Front View of a Frontend Enclosure (with a Front Cover)

1 2

1 System operation panel


(Refer to "■ System Operation Panel" (page 207).)
2 Front cover

204 Configuration Guide (Basic)


A. Component Names
Frontend Enclosures (ETERNUS DX900 S5)

Figure 25 Front View of a Frontend Enclosure (without a Front Cover)


2 3 3

FANU#2 FANU#3

SVC#1
1

FANU#0 FANU#1

SVC#0
1

3 3

1 SVC (SVC#0, SVC#1)


(Refer to "■ Service Controllers (SVC)" (page 210).)
2 FEMP-BRG
3 Fan unit (FANU#0, FANU#1, FANU#2, FANU#3)
A unit for cooling the inside of the ETERNUS DX. The unit controls the temperature inside the ETERNUS DX.
Four units are installed in a frontend enclosure.

205 Configuration Guide (Basic)


A. Component Names
Frontend Enclosures (ETERNUS DX900 S5)

Rear
This section provides the names of the components in the rear of a frontend enclosure.

Figure 26 Rear View of a Frontend Enclosure


1 1

FRT#3 2
FPSU#2 FPSU#3

FRT#2 2

FRT#1 2
FPSU#0 FPSU#1

FRT#0 2

1 1

1 Power supply units (FPSU#0, FPSU#1, FPSU#2, FPSU#3)


(Refer to "■ Power Supply Units" (page 211).)
2 Frontend routers (FRT#0, FRT#1, FRT#2, FRT#3)
(Refer to "■ Frontend Routers (FRT)" (page 211).)

206 Configuration Guide (Basic)


A. Component Names
Frontend Enclosures (ETERNUS DX900 S5)

Component Names and LED Names


This section describes the operation panel of the frontend enclosure.

■ System Operation Panel


The system operation panel on the front of the frontend enclosure has LEDs, an LCD panel, panel keys, and a
Power switch.

Figure 27 System Operation Panel

POWER LED

1 2 3

1 LEDs
(Refer to "● LEDs" (page 207).)
2 LCD panel
(Refer to "● LCD Panel" (page 208).)
3 Panel keys
(Refer to "● Panel Keys" (page 210).)
4 Power switch
(Refer to "● Power Switch" (page 210).)

● LEDs
LEDs are lamps that indicate the status of the ETERNUS DX.
The LEDs turn on or blink to indicate the statuses that are listed below.

Table 12 Status and Meaning of Each LED (System Operation Panel)


LED name LED status Meaning

POWER Power is supplied.


(green)

IDENTIFY The installation location of the frontend enclosure is identified


(blinks blue) according to the instruction that is issued from ETERNUS Web GUI or
ETERNUS CLI.

FAULT The ETERNUS DX is in error status.


(amber)

A part of the ETERNUS DX requires preventive maintenance.


(blinks amber)

207 Configuration Guide (Basic)


A. Component Names
Frontend Enclosures (ETERNUS DX900 S5)

LED name LED status Meaning

MAINTENANCE Maintenance for the ETERNUS DX is in progress.


(green)

Maintenance (from ETERNUS Web GUI or ETERNUS CLI) for the


(blinks green) ETERNUS DX is in progress or a status check of the ETERNUS DX is
necessary.

CACHE (green) There is data in the cache memory of the ETERNUS DX.

READY The ETERNUS DX is available for use.


(green)

REMOTE The ETERNUS DX is turned on and off with the server.


(green)

FUNCTION Indicates that a menu operation from the system operation panel is
(green)
being performed.

● LCD Panel
This is a liquid crystal display panel. Various information of the ETERNUS DX is displayed.
The information is classified as shown below:
• Displaying the status of the ETERNUS DX
• Displaying warning messages when an error has occurred in the ETERNUS DX
• Menu operation using the panel key
For details on the menu operations, refer to "● Panel Keys" (page 210).
The following types of warning messages are displayed on the LCD panel:
• Messages that are displayed during startup
• Messages that are displayed while running (or operating)
The message format for each warning message is described below.

● Messages That Are Displayed during Startup


The message format that is displayed on the LCD panel during startup is shown in Figure 28.

Figure 28 Message Format of the LCD Panel (during Startup)


1 2

*boot* -CM00
POST-XXXX-------

1 General status
2 Target component
3 Component state / component error message

208 Configuration Guide (Basic)


A. Component Names
Frontend Enclosures (ETERNUS DX900 S5)

● Messages That Are Displayed While Running (or Operating)


The message format that is displayed on the LCD panel while running (or operating) is shown in Figure
29.

Figure 29 Message Format of the LCD Panel (While Running)


1 2

Error- XX/YY Top row

YYYYYYYYYYYYYYYY Bottom row

1 Overall state of the ETERNUS DX


2 Number of indicated alarms
3 System name of the ETERNUS DX or information of a component where an error has occurred

The meaning of the message in the top and bottom rows of the LCD panel is shown in Table 13.

Table 13 Meaning of the Message on the LCD Panel (While Running)


The displayed messages and their meaning

Top row Overall state of the ETERNUS Normal The ETERNUS DX is running normally.
DX Error A failed component exists in the ETERNUS DX.
Contact your maintenance engineer.

Warning A component requiring a preventive replacement exists


in the ETERNUS DX.
Contact your maintenance engineer.

WrtThrough The ETERNUS DX is in a Write Through state. Contact


your maintenance engineer.
If a failed component exists in the ETERNUS DX, the
Error or Warning display is given priority.

PinnedData Pinned data exists in the ETERNUS DX. Contact your


maintenance engineer.
If a failed component exists in the ETERNUS DX, the
Error or Warning display is given priority.

Number of indicated alarms The currently displayed alarm number and the total number of alarms are
displayed.
XX: Alarm number that is currently displayed
YY: Total number of alarms

Bottom System name of the ETERNUS YYYYYYYYYYYYYYYY The system name of the ETERNUS DX is displayed when
row DX or information of a running normally.
component where an error
has occurred

209 Configuration Guide (Basic)


A. Component Names
Frontend Enclosures (ETERNUS DX900 S5)

● Panel Keys
The name and function of each panel key are described in Table 14.

Table 14 Name and Function of the Panel Key


Panel key name Function

FUNCTION Starts the menu operation or selects the menu.

INPUT Confirms or executes the menu operation.

DISPLAY Displays multiple messages on the LCD panel.

CURSOR Moves the cursor in the LCD panel.

SETTING Inputs data into the LCD panel.

CLEAR Cancels or terminates the menu operation.

For details on the menu operations using the panel keys, refer to "Menu Operation Using the Panel Key"
(page 212).

● Power Switch
This switch is used to turn on or off the ETERNUS DX.
• The ETERNUS DX that is currently off is turned on by pressing the Power switch.
• The ETERNUS DX that is currently on is turned off by pressing the Power switch for four seconds or more.
• Power switch operations are disabled during the remote mode (or when the REMOTE LED is turned on).
• Power switch operations are available when both the remote mode (or when the REMOTE LED is turned
on) and the maintenance state (or when the MAINTENANCE LED is turned on) are enabled.

■ Service Controllers (SVC)


An SVC coordinates with the controller and is a unit that controls the monitoring function for the entire ETERNUS
DX.
Two units are installed in a frontend enclosure.

Figure 30 Service Controller


1

1 CM ports
This port is used to connect SVCs and CMs.
2 PWC port
The PWC port is used to connect a power synchronized unit to perform power synchronization.

210 Configuration Guide (Basic)


A. Component Names
Frontend Enclosures (ETERNUS DX900 S5)

■ Power Supply Units


The power supply unit transforms input AC power from a power socket to DC power and supplies power to each
component.
Four units are installed in a frontend enclosure.

Figure 31 Power Supply Unit (Frontend Enclosure)

POWER LED

FAULT LED

1 Inlet
This inlet is used to connect a power cord.

The states of LEDs are listed below.

Table 15 Status and Meaning of Each LED (Power Supply Unit)


LED name LED status Meaning

POWER AC power is supplied to the power supply unit.


(green)

FAULT The power supply unit is in error status.


(amber)

■ Frontend Routers (FRT)


A route switch used for connecting between controllers. Four units are installed in a frontend enclosure.
An FRT connects to a maximum of eight controllers.

Figure 32 Frontend Routers


1

#0 #1 #2 #3 CM#1

#0 #1 #2 #3 CM#0

1 CM ports (CM#0, CM#1)


This port is used to connect SVCs and CMs.

211 Configuration Guide (Basic)


A. Component Names
Frontend Enclosures (ETERNUS DX900 S5)

Menu Operation Using the Panel Key


Various functions can be performed using the panel keys in the system operation panel.
The following functions can be performed using the panel keys.
• Switching the power mode to remote mode
• Switching the power mode to local mode
This section explains the types and functions of the menu operation using the panel keys, and the operational
procedure of each function.

■ Menu Types
A menu list is shown in Table 16.

Table 16 Menu List for the LCD Panel


Menu shown on the LCD Panel Function

Menu0:REMOTE MOD Switches the power mode to remote mode (which turns the power on and off via the power
synchronized unit or SCCI).

Menu1:LOCAL MOD Switches the power mode to local mode (which turns the power on and off via the Power
switch).

Menu2:MAINT MOD Switches the maintenance mode on and off. This menu is for use by the maintenance engineer.
Do not use this menu.

Menu3:PASS WORD Inputs a password. This menu is for use by the maintenance engineer. Do not use this menu.

■ Switching the Power Mode to Remote Mode


To switch the power mode to remote mode, select "Menu0:REMOTE MOD".

Note
• The power mode can be changed even if the power (or DC power) of the ETERNUS DX is turned off.
The power mode that was set is enabled after turning on the power.
• The display can be returned to the previous display by pressing the CLEAR key until the confirmation
message is responded to.
• The menu operation may not be available if the operation is performed such as when the ETERNUS DX is
starting, and the "Not Available" message may blink on the LCD panel. In this case, press the CLEAR key
to terminate the menu operation.

The operating procedure is described below.

1 Turn on the ETERNUS DX.


For methods to turn on the power, refer to "Powering On" (page 70).

212 Configuration Guide (Basic)


A. Component Names
Frontend Enclosures (ETERNUS DX900 S5)

2 Press the FUNCTION key for two seconds or more.

"Menu0:REMOTE MOD" is displayed on the LCD panel.

3 Press the INPUT key.

4 Press the INPUT key again after the confirmation message "[YES]/NO" is displayed on the bottom row of
the LCD panel.
When the INPUT key is pressed, the REMOTE LED is turned on and the ETERNUS DX is set to remote mode.
When the remote mode is set, the selection message for the remote mode "[YES]/NO" is cleared and the
display returns to "Menu0:REMOTE MOD".

5 Press the CLEAR key to terminate the menu operation.

213 Configuration Guide (Basic)


A. Component Names
Frontend Enclosures (ETERNUS DX900 S5)

■ Switching the Power Mode to Local Mode


To switch the power mode to local mode, select "Menu1:LOCAL MOD".

Note
• The power mode can be changed even if the power (or DC power) of the ETERNUS DX is turned off.
The power mode that was set is enabled after turning on the power.
• The display can be returned to the previous display by pressing the CLEAR key before responding to the
confirmation message.
• The menu operation may not be available if the operation is performed such as when the ETERNUS DX is
starting, and the "Not Available" message may blink on the LCD panel. In this case, press the CLEAR key
to terminate the menu operation.

The operating procedure is described below.

1 Turn on the ETERNUS DX.


For methods to turn on the power, refer to "Powering On" (page 70).

2 Press the FUNCTION key for two seconds or more.

"Menu0:REMOTE MOD" is displayed on the LCD panel.

3 Repeatedly press the FUNCTION key until "Menu1:LOCAL MOD" is displayed.

4 Press the INPUT key.

5 Press the INPUT key again after the confirmation message "[YES]/NO" is displayed on the bottom row of
the LCD panel.
When the INPUT key is pressed, the REMOTE LED is turned off and the ETERNUS DX is set to local mode.

214 Configuration Guide (Basic)


A. Component Names
Frontend Enclosures (ETERNUS DX900 S5)

When the local mode is set, the selection message for the local mode "[YES]/NO" is cleared and the
display returns to "Menu1:LOCAL MOD".

6 Press the CLEAR key to terminate the menu operation.

215 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

Controller Enclosure
An operation panel and drives are installed in the front of the ETERNUS DX controller enclosure. Controllers and
power supply units are installed in the rear.

Front
This section provides the names of the components in the front of a controller enclosure.

■ ETERNUS DX60 S5/DX100 S5/DX200 S5

Figure 33 Front View of a 2.5" Type Controller Enclosure (ETERNUS DX60 S5/DX100 S5/DX200 S5)

1 2
Slot#10
Slot#11
Slot#12
Slot#13
Slot#14
Slot#15

Slot#16
Slot#17
Slot#18
Slot#19
Slot#20
Slot#21
Slot#22
Slot#23
Slot#0
Slot#1
Slot#2
Slot#3
Slot#4
Slot#5
Slot#6
Slot#7

Slot#8
Slot#9

3 3

1 Operation panel (refer to "■ Operation Panel" (page 226))


2 2.5" drive (refer to "■ Drives" (page 229))
3 Flange cover

Figure 34 Front View of a 3.5" Type Controller Enclosure (ETERNUS DX60 S5/DX100 S5/DX200 S5)

1 2

Slot#8 Slot#9 Slot#10 Slot#11

Slot#4 Slot#5 Slot#6 Slot#7

Slot#0 Slot#1 Slot#2 Slot#3

3 3

1 Operation panel (refer to "■ Operation Panel" (page 226))


2 3.5" drive (refer to "■ Drives" (page 229))
3 Flange cover

216 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

■ ETERNUS DX500 S5/DX600 S5

Figure 35 Front View of a Controller Enclosure (for the ETERNUS DX500 S5/DX600 S5, with a Front Cover)

1 2

1 Operation panel (refer to "■ Operation Panel" (page 226))


2 Front cover

Figure 36 Front View of a Controller Enclosure (for the ETERNUS DX500 S5/DX600 S5, without a Front Cover)
1 2
Slot#10
Slot#11
Slot#12
Slot#13
Slot#14
Slot#15

Slot#16
Slot#17
Slot#18
Slot#19
Slot#20
Slot#21
Slot#22
Slot#23
Slot#0
Slot#1
Slot#2
Slot#3
Slot#4
Slot#5
Slot#6
Slot#7
Slot#8
Slot#9

BBU#0 BBU#1

3 3

1 2.5" drive (refer to "■ Drives" (page 229))


2 2.5" drive / PCIe Flash Module
(Refer to "■ Drives" (page 229) and "■ PCIe Flash Modules (PFM)" (page 241))
3 Battery (BBU#0, BBU#1) (refer to "■ Batteries" (page 242))

217 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

■ ETERNUS DX900 S5

Figure 37 Front View of a Controller Enclosure (for ETERNUS DX900 S5, with a Front Cover)

1 2

1 Operation panel (refer to "■ Operation Panel" (page 226))


2 Front cover

Figure 38 Front View of a Controller Enclosure (for ETERNUS DX900 S5, without a Front Cover)
1 2
Slot#10
Slot#11
Slot#12
Slot#13
Slot#14
Slot#15

Slot#16
Slot#17
Slot#18
Slot#19
Slot#20
Slot#21
Slot#22
Slot#23
Slot#0
Slot#1
Slot#2
Slot#3
Slot#4
Slot#5
Slot#6
Slot#7
Slot#8
Slot#9

BBU#0 BBU#1

3 3

1 2.5" drive (refer to "■ Drives" (page 229))


2 2.5" drive / PCIe Flash Module
(Refer to "■ Drives" (page 229) and "■ PCIe Flash Modules (PFM)" (page 241))
3 Battery (BBU#0, BBU#1) (refer to "■ Batteries" (page 242))

218 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

Rear
This section provides the names of the components in the rear of a controller enclosure.

■ ETERNUS DX60 S5

Figure 39 Rear View of a Controller Enclosure (When the ETERNUS DX60 S5 Is installed with Only One
Controller)
1
2 3 4 5 6 7

CM#0

PSU#0 PSU#1

8 8

1 Controller (CM#0) (refer to "■ Controllers" (page 230))


2 PWC port
This port is used to connect a power synchronized unit with an RS232C cable.
3 Host interface
This interface is used for connecting a controller with a server.
4 Drive interface (OUT) port
This port is used to connect a controller enclosure to a drive enclosure with a mini SAS HD cable between
enclosures.
5 RMT (LAN) port
This port is used for connecting a LAN cable and used for separating the network (such as for the remote
support) from the MNT port for operation management. This port uses an RJ-45 connector.
6 MNT (LAN) port
This port is used for connecting a LAN cable and used for operation management. This port uses an RJ-45
connector.
7 Cover
Remove this when installing an additional controller (optional).
8 Power supply units (PSU#0, PSU#1) (refer to "■ Power Supply Units" (page 235))

Figure 40 Rear View of a Controller Enclosure (When the ETERNUS DX60 S5 Is Installed with Two Controllers)
1 1
2 3 4 5 6 2 3 4 5 6

CM#0 CM#1

PSU#0 PSU#1

7 7

219 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

1 Controllers (CM#0, CM#1) (refer to "■ Controllers" (page 230))


2 PWC port
This port is used to connect a power synchronized unit with an RS232C cable.
3 Host interface
This interface is used for connecting a controller with a server.
4 Drive interface (OUT) port
This port is used to connect a controller enclosure to a drive enclosure with a mini SAS HD cable between
enclosures.
5 RMT (LAN) port
This port is used for connecting a LAN cable and used for separating the network (such as for the remote
support) from the MNT port for operation management. This port uses an RJ-45 connector.
6 MNT (LAN) port
This port is used for connecting a LAN cable and used for operation management. This port uses an RJ-45
connector.
7 Power supply units (PSU#0, PSU#1) (refer to "■ Power Supply Units" (page 235))

220 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

■ ETERNUS DX100 S5/DX200 S5

Figure 41 Rear View of a Controller Enclosure (When the ETERNUS DX100 S5/DX200 S5 Is Installed with Only
One Controller)
1
2 3 4 5 3 6 7

CM#0
CA#0 CA#1

PSU#0 PSU#1

8 8

1 Controller (CM#0) (refer to "■ Controllers" (page 230))


2 PWC port
This port is used to connect a power synchronized unit with an RS232C cable.
3 Host interfaces (CA#0, CA#1) (refer to "■ Host Interface" (page 237))
4 Drive interface (OUT) port
This port is used to connect a controller enclosure to a drive enclosure with a mini SAS HD cable between
enclosures.
5 RMT (LAN) port
This port is used for connecting a LAN cable and used for separating the network (such as for the remote
support) from the MNT port for operation management. This port uses an RJ-45 connector.
6 MNT (LAN) port
This port is used for connecting a LAN cable and used for operation management. This port uses an RJ-45
connector.
7 Cover
Remove this when installing an additional controller (optional).
8 Power supply units (PSU#0, PSU#1) (refer to "■ Power Supply Units" (page 235))

221 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

Figure 42 Rear View of a Controller Enclosure (When the ETERNUS DX100 S5/DX200 S5 Is Installed with Two
Controllers)
1 1
2 3 4 5 3 6 2 3 4 5 3 6

CM#0 CM#1
CA#0 CA#1 CA#0 CA#1

PSU#0 PSU#1

7 7

1 Controller (CM#0, CM#1) (refer to "■ Controllers" (page 230))


2 PWC port
This port is used to connect a power synchronized unit with an RS232C cable.
3 Host interfaces (CA#0, CA#1) (refer to "■ Host Interface" (page 237))
4 Drive interface (OUT) port
This port is used to connect a controller enclosure to a drive enclosure with a mini SAS HD cable between
enclosures.
5 RMT (LAN) port
This port is used for connecting a LAN cable and used for separating the network (such as for the remote
support) from the MNT port for operation management. This port uses an RJ-45 connector.
6 MNT (LAN) port
This port is used for connecting a LAN cable and used for operation management. This port uses an RJ-45
connector.
7 Power supply units (PSU#0, PSU#1) (refer to "■ Power Supply Units" (page 235))

222 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

■ ETERNUS DX500 S5

Figure 43 Rear View of a Controller Enclosure (ETERNUS DX500 S5)


1 1 2 2
BUD#0
BUD#1
CM#1

CA#0 CA#1

CPSU#0 CPSU#1
BUD#0
BUD#1

CM#0

CA#0 CA#1

8 9 9 8
3 4 5 6 7

1 Controllers (CM#0, CM#1)


(Refer to "■ Controllers" (page 230).)
2 Host interfaces (CA#0, CA#1)
(Refer to "■ Host Interface" (page 237).)
3 RMT (LAN) port
This port is used for connecting a LAN cable and used for separating the network (such as for the remote
support) from the MNT port for operation management. This port uses an RJ-45 connector.
4 MNT (LAN) port
This port is used for connecting a LAN cable and used for operation management. This port uses an RJ-45
connector.
5 FST (LAN) port
A port that is dedicated for maintenance engineers. Customers must not use this port.
6 Drive interface (OUT) port
This port is used to connect a controller enclosure to a drive enclosure with a mini SAS HD cable between
enclosures.
7 PWC port
This port is used to connect a power synchronized unit with an RS232C cable.
8 Power supply units (CPSU#0, CPSU#1)
(Refer to "■ Power Supply Units" (page 235).)
9 BUD (BUD#0, BUD#1)
(Refer to "■ BUD" (page 242).)

223 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

■ ETERNUS DX600 S5

Figure 44 Rear View of a Controller Enclosure (ETERNUS DX600 S5)


1 1 2 2
BUD#0
BUD#1
CA#2 CA#3
CM#1
CA#0 CA#1

CPSU#0 CPSU#1
BUD#0
BUD#1

CA#2 CA#3
CM#0
CA#0 CA#1

8 9 9 8
3 4 5 6 7

1 Controllers (CM#0, CM#1)


(Refer to "■ Controllers" (page 230).)
2 Host interfaces (CA#0, CA#1, CA#2, CA#3)
(Refer to "■ Host Interface" (page 237).)
3 RMT (LAN) port
This port is used for connecting a LAN cable and used for separating the network (such as for the remote
support) from the MNT port for operation management. This port uses an RJ-45 connector.
4 MNT (LAN) port
This port is used for connecting a LAN cable and used for operation management. This port uses an RJ-45
connector.
5 FST (LAN) port
A port that is dedicated for maintenance engineers. Customers must not use this port.
6 Drive interface (OUT) port
This port is used to connect a controller enclosure to a drive enclosure with a mini SAS HD cable between
enclosures.
7 PWC port
This port is used to connect a power synchronized unit with an RS232C cable.
8 Power supply units (CPSU#0, CPSU#1)
(Refer to "■ Power Supply Units" (page 235).)
9 BUD (BUD#0, BUD#1)
(Refer to "■ BUD" (page 242).)

224 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

■ ETERNUS DX900 S5

Figure 45 Rear View of a Controller Enclosure (ETERNUS DX900 S5)


1 1 2 2
BUD#0
BUD#1
CA#2 CA#3
CM#1
CA#0 CA#1

CPSU#0 CPSU#1
BUD#0
BUD#1

CA#2 CA#3
CM#0
CA#0 CA#1

9 10 10 9
7 8
3 4 5 6

1 Controllers (CM#0, CM#1)


(Refer to "■ Controllers" (page 230).)
2 Host interfaces (CA#0, CA#1, CA#2, CA#3)
(Refer to "■ Host Interface" (page 237).)
3 RMT (LAN) port
This port is used for connecting a LAN cable and used for separating the network (such as for the remote
support) from the MNT port for operation management. This port uses an RJ-45 connector.
4 MNT (LAN) port
This port is used for connecting a LAN cable and used for operation management. This port uses an RJ-45
connector.
5 FST (LAN) port
A port that is dedicated for maintenance engineers. Customers must not use this port.
6 Drive interface (OUT) port
This port is used to connect a controller enclosure to a drive enclosure with a mini SAS HD cable between
enclosures.
7 FRT ports
This port is used to connect CMs and FRTs.
8 SVC ports
This port is used to connect CMs and SVCs.
9 Power supply units (CPSU#0, CPSU#1)
(Refer to "■ Power Supply Units" (page 235).)
10 BUD (BUD#0, BUD#1)
(Refer to "■ BUD" (page 242).)

225 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

Component Names and LED Names


This section describes the operation panel, the drives, the controllers, the power supply units, the host
interfaces, the PCIe Flash Modules (PFMs), the batteries, and the BUDs of the controller enclosure.

■ Operation Panel
● ETERNUS DX60 S5/DX100 S5/DX200 S5
An operation panel has LEDs, a Power switch, and a FUNCTION button.

Figure 46 Operation Panel (ETERNUS DX60 S5/DX100 S5/DX200 S5)


With a flange cover Without a flange cover

1
1 POWER LED POWER LED

IDENTIFY LED FAULT LED IDENTIFY LED FAULT LED

MAINTENANCE LED CACHE LED MAINTENANCE LED CACHE LED


2
READY LED READY LED

1 Power switch
This switch is used to turn on or off the ETERNUS DX.
2 FUNCTION button
This button is used to switch the maintenance status on or off, to switch the master CM (when two
controllers are mounted), to initialize the LAN ports, or to initialize the user settings.

The LEDs turn on or blink to indicate the statuses that are listed below.

Table 17 Status and Meaning of Each LED (Operation Panel [Controller Enclosure for the ETERNUS DX60
S5/DX100 S5/DX200 S5])
LED name LED status Meaning

POWER DC power is supplied to the controller enclosure.


(green)

IDENTIFY The installation location of the controller enclosure is identified


(blinks blue) according to the instruction that is issued from ETERNUS Web GUI or
ETERNUS CLI.

FAULT The ETERNUS DX is in error status.


(amber) (*1)

A part of the ETERNUS DX requires preventive maintenance.


(blinks amber)

MAINTENANCE Maintenance for the ETERNUS DX is in progress.


(green)

Maintenance (from ETERNUS Web GUI or ETERNUS CLI) for the


(blinks green) ETERNUS DX is in progress or a status check of the ETERNUS DX is
necessary.

226 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

LED name LED status Meaning

CACHE (green) There is data in the cache memory of the ETERNUS DX.

READY The ETERNUS DX is available for use.


(green) (*1)

*1: When the READY LED and the FAULT LED are both on at the same time, an error has occurred while the Unified configuration is
starting up.

● ETERNUS DX500 S5/DX600 S5


An operation panel has LEDs, a Power switch, and setting change switches.

Figure 47 Operation Panel (Controller Enclosure for the ETERNUS DX500 S5/DX600 S5)
With a front cover Without a front cover

2 4
3

1 POWER LED

IDENTIFY LED FAULT LED

MAINTENANCE LED CACHE LED

READY LED REMOTE LED

1 Power switch
This switch is used to turn on or off the ETERNUS DX.
2 MNT SW (maintenance switch)
This switch is used to switch the maintenance status on or off.
3 IP RST SW (IP reset switch)
This switch is used to initialize the LAN ports or to initialize the user information.
4 MST SW (CM Master Change switch)
This switch is used to change the Master CM.

The LEDs turn on or blink to indicate the statuses that are listed below.

Table 18 Status and Meaning of Each LED (Operation Panel [Controller Enclosure for the ETERNUS DX500
S5/DX600 S5])
LED name LED status Meaning

POWER Power is supplied to the controller enclosure.


(green)

IDENTIFY The installation location of the controller is identified according to


(blinks blue) the instruction that is issued from ETERNUS Web GUI or ETERNUS CLI.

227 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

LED name LED status Meaning

FAULT The ETERNUS DX is in error status.


(amber) (*1)

A part of the ETERNUS DX requires preventive maintenance.


(blinks amber)

MAINTENANCE Maintenance for the ETERNUS DX is in progress.


(green)

Maintenance (from ETERNUS Web GUI or ETERNUS CLI) for the


(blinks green) ETERNUS DX is in progress or a status check of the ETERNUS DX is
necessary.

CACHE (green) There is data in the cache memory of the ETERNUS DX.

READY The ETERNUS DX is available for use.


(green) (*1)

REMOTE The ETERNUS DX is turned on and off with the server.


(green)

*1: When the READY LED and the FAULT LED are both on at the same time, an error has occurred while the Unified configuration is
starting up.

● ETERNUS DX900 S5
An operation panel has a CE-ID display and LEDs.

Figure 48 Operation Panel (Controller Enclosure [ETERNUS DX900 S5])


With a front cover Without a front cover

1 2 4
3

POWER LED

IDENTIFY LED FAULT LED

MAINTENANCE LED

READY LED

1 CE-ID
The CE-ID (controller enclosure number) of the controller enclosure is displayed.
2 MNT SW (maintenance switch)
This switch is used to switch the maintenance status on or off.
3 IP RST SW (IP reset switch)
This switch is used to initialize the LAN ports or to initialize the user information.
4 MST SW (CM Master Change switch)
This switch is used to change the Master CM.

228 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

The LEDs turn on or blink to indicate the statuses that are listed below.

Table 19 Status and Meaning of Each LED (Operation Panel [Controller Enclosure (ETERNUS DX900 S5)])
LED name LED status Meaning

POWER Power is supplied to the controller enclosure.


(green)

IDENTIFY The installation location of the controller enclosure is identified


(blinks blue) according to the instruction that is issued from ETERNUS Web GUI or
ETERNUS CLI.

FAULT The controller enclosure is in error status.


(amber)

A part of the controller enclosure requires preventive maintenance.


(blinks amber)

MAINTENANCE The controller enclosure is currently under maintenance.


(green)

The controller enclosure is currently under maintenance (from


(blinks green) ETERNUS Web GUI or ETERNUS CLI), or a status check of the ETERNUS
DX is necessary.

READY The controller enclosure is available for use.


(green)

■ Drives
2.5" drives and 3.5" drives have LEDs.

Figure 49 2.5" Drives and 3.5" Drives


2.5" drive 3.5" drive
DRIVE READY LED
DRIVE FAULT LED
DRIVE READY LED

DRIVE FAULT LED

The LEDs turn on or blink to indicate the statuses that are listed below.

Table 20 Status and Meaning of Each LED (Drive)


LED name LED status Meaning

DRIVE READY The drive is in normal status.


(green)

(blinks green)

DRIVE FAULT • The drive is in error status.


(amber) • The LED light up operation was performed from the ETERNUS CLI
command line in order to identify the drive location.

229 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

■ Controllers
The controller contains a CPU, system memory, Battery Backup Unit (BBU), host interfaces, drive interface (DI)
ports, and LAN ports. The controller controls all operations in the ETERNUS DX.

● ETERNUS DX60 S5

Figure 50 Controller (for the ETERNUS DX60 S5, Pattern 1)


CA#0 FAULT LED
IDENTIFY/BBU FAULT LED READY/FAULT LED
DI (OUT) LINK/FAULT LED MASTER LED

LAN LINK LED LAN LINK LED


LAN ACT LED LAN ACT LED

Figure 51 Controller (for the ETERNUS DX60 S5, Pattern 2)


IDENTIFY/BBU FAULT LED
CA#0 FAULT LED READY/FAULT LED
DI (OUT) LINK/FAULT LED MASTER LED

LAN LINK LED LAN LINK LED


LAN ACT LED LAN ACT LED

The LEDs turn on or blink to indicate the statuses that are listed below.

Table 21 Status and Meaning of Each LED (Controller for the ETERNUS DX60 S5)
LED name LED status Meaning

IDENTIFY/BBU FAULT The installation location of the controller is identified according to


(blinks blue) the instruction that is issued from ETERNUS Web GUI or ETERNUS CLI.

The battery is in error status.


(amber)

DI (OUT) LINK/FAULT The link between the DI (OUT) port and the destination port has been
(green) established.

• The link between the DI (OUT) port and the destination port is in
(amber) error status.
• The ports to remove the cables between enclosures from are
indicated. This occurs while a drive enclosure is being added.

The ports to connect the cables are indicated. This occurs while a
(blinks amber) drive enclosure is being added.

LAN ACT Data is being sent or received via the LAN port.
(blinks green)

LAN LINK The link between the LAN port and the destination port has been
(green) established.

230 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

LED name LED status Meaning

READY/FAULT The controller is in normal status.


(green)

An error has occurred during startup.


(blinks green)

• The controller is performing the initial setup after the power is


(amber) turned on.
• The controller is in error status.
(blinks amber)

CA FAULT The host interface is in error status.


(amber)

MASTER The controller is set as a Master CM.


(green)

● ETERNUS DX100 S5/DX200 S5

Figure 52 Controller (for the ETERNUS DX100 S5/DX200 S5, Pattern 1)


DI (OUT) LINK/FAULT LED READY/FAULT LED
LINK/FAULT LED CA#1 FAULT LED
CA#0 FAULT LED MASTER LED

IDENTIFY/BBU FAULT LED LAN ACT LED LAN LINK LED


LAN LINK LED LAN ACT LED
LINK/FAULT LED

Figure 53 Controller (for the ETERNUS DX100 S5/DX200 S5, Pattern 2)


DI (OUT) LINK/FAULT LED READY/FAULT LED
CA#0 FAULT LED CA#1 FAULT LED
IDENTIFY/BBU FAULT LED MASTER LED

LINK/FAULT LED LAN LINK LED


LAN ACT LED LAN ACT LED
LAN LINK LED LINK/FAULT LED

Table 22 Status and Meaning of Each LED (Controller for the ETERNUS DX100 S5/DX200 S5)
LED name LED status Meaning

IDENTIFY/BBU FAULT The installation location of the controller is identified according to


(blinks blue) the instruction that is issued from ETERNUS Web GUI or ETERNUS CLI.

The battery is in error status.


(amber)

231 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

LED name LED status Meaning

DI (OUT) LINK/FAULT The link between the DI (OUT) port and the destination port has been
(green) established.

• The link between the DI (OUT) port and the destination port is in
(amber) error status.
• The ports to remove the cables between enclosures from are
indicated. This occurs while a drive enclosure is being added.

The ports to connect the cables are indicated. This occurs while a
(blinks amber) drive enclosure is being added.

READY/FAULT The controller is in normal status.


(green)

An error has occurred during startup.


(blinks green)

• The controller is performing the initial setup after the power is


(amber) turned on.
• The controller is in error status.
(blinks amber)

MASTER The controller is set as a Master CM.


(green)

CA FAULT The host interface is in error status.


(amber)

LINK/FAULT The link between the host interface port and the destination port has
(green) been established.

The host interface port is in error status.


(amber)

LAN ACT Data is being sent or received via the LAN port.
(blinks green)

LAN LINK The link between the LAN port and the destination port has been
(green) established.

● ETERNUS DX500 S5/DX600 S5

Figure 54 Controller (ETERNUS DX500 S5)


BUD READY LED

BUD FAULT LED DI (OUT) LINK/FAULT LED


READY/FAULT LED MASTER LED
IDENTIFY LED

LAN ACT LED


LAN LINK LED

232 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

Figure 55 Controller (ETERNUS DX600 S5)


BUD READY LED

BUD FAULT LED DI (OUT) LINK/FAULT LED


READY/FAULT LED MASTER LED
IDENTIFY LED

LAN ACT LED


LAN LINK LED

The LEDs turn on or blink to indicate the statuses that are listed below.

Table 23 Status and Meaning of Each LED (Controller for the ETERNUS DX500 S5/DX600 S5)
LED name LED status Meaning

READY/FAULT The controller is in normal status.


(green)

An error has occurred during startup.


(blinks green)

• The controller is in error status.


(amber) • An error has occurred during startup.

(blinks amber)

IDENTIFY The installation location of the controller is identified according to


(blinks blue) the instruction that is issued from ETERNUS Web GUI or ETERNUS CLI.

LAN LINK The link between the LAN port and the destination port has been
(green) established.

LAN ACT Data is being sent or received via the LAN port.
(blinks green)

MASTER The controller is set as a Master CM.


(green)

DI (OUT) LINK/FAULT The link between the DI (OUT) port and the destination port has been
(green) established.

• The link between the DI (OUT) port and the destination port is in
(amber) error status.
• The ports to remove the cables between enclosures from are
indicated. This occurs while a drive enclosure is being added.

The ports to connect the cables are indicated. This occurs while a
(blinks amber) drive enclosure is being added.

BUD READY The BUD is in normal status.


(green)

BUD FAULT The BUD is in error status.


(amber)

233 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

● ETERNUS DX900 S5

Figure 56 Controller (ETERNUS DX900 S5)


BUD FAULT LED

BUD READY LED DI (OUT) LINK/FAULT LED


READY/FAULT LED MASTER LED
FRT READY LED
FRT FAULT LED
IDENTIFY LED

SVC READY LED LAN ACT LED


SVC FAULT LED LAN LINK LED

The LEDs turn on or blink to indicate the statuses that are listed below.

Table 24 Status and Meaning of Each LED (Controller for the ETERNUS DX900 S5)
LED name LED status Meaning

READY/FAULT The controller is in normal status.


(green)

An error has occurred during startup.


(blinks green)

• The controller is in error status.


(amber) • An error has occurred during startup.

(blinks amber)

IDENTIFY The installation location of the controller is identified according to


(blinks blue) the instruction that is issued from ETERNUS Web GUI or ETERNUS CLI.

LAN LINK The link between the LAN port and the destination port has been
(green) established.

LAN ACT Data is being sent or received via the LAN port.
(blinks green)

MASTER The controller is set as a Master CM.


(green)

DI (OUT) LINK/FAULT The link between the DI (OUT) port and the destination port has been
(green) established.

• The link between the DI (OUT) port and the destination port is in
(amber) error status.
• The ports to remove the cables between enclosures from are
indicated. This occurs while a drive enclosure is being added.

The ports to connect the cables are indicated. This occurs while a
(blinks amber) drive enclosure is being added.

BUD READY The BUD is in normal status.


(green)

234 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

LED name LED status Meaning

BUD FAULT The BUD is in error status.


(amber)

FRT READY The FRT is in normal status.


(green)

FRT FAULT The FRT is in error status.


(amber)

SVC READY The SVC is in normal status.


(green)

SVC FAULT The SVC is in error status.


(amber)

■ Power Supply Units


There are two types of the power supply units: AC power type and DC power type. The AC power type power
supply unit converts input AC power from a power socket to DC power and supplies power to each component.
A controller enclosure has two power supply units.
Each power supply unit contains fans.

● ETERNUS DX60 S5/DX100 S5/DX200 S5

Figure 57 Power Supply Unit (Controller Enclosure for the ETERNUS DX60 S5/DX100 S5/DX200 S5) (AC
Power Type)

POWER LED FAN FAIL LED


FAULT LED AC MISSING LED 1 2

Figure 58 Power Supply Unit (Controller Enclosure for the ETERNUS DX100 S5) (DC Power Type)

POWER LED FAN FAIL LED


FAULT LED AC MISSING LED
2

1 PSU switch
This switch is used to turn on and off the power supply.
2 Inlet
This inlet is used to connect a power cord.

235 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

The LEDs turn on or blink to indicate the statuses that are listed below.

Table 25 Status and Meaning of Each LED (Power Supply Unit [Controller Enclosure for the ETERNUS DX60
S5/DX100 S5/DX200 S5])
LED name LED status Meaning

POWER Power is supplied to the power supply unit.


(green)

Power is supplied to the power supply unit, but DC power is not


(blinks green) supplied to the ETERNUS DX.

FAULT Power is not supplied to the power supply unit.


(amber)

AC MISSING Power is not supplied to this power supply unit, but AC power is
(amber) supplied to the other power supply unit.

FAN FAIL The power supply unit or the fan in the power supply unit is in error
(amber) status.

● ETERNUS DX500 S5/DX600 S5/DX900 S5

Figure 59 Power Supply Unit (Controller Enclosure for the ETERNUS DX500 S5/DX600 S5/DX900 S5)

POWER LED

FAULT LED

1 Inlet
This inlet is used to connect a power cord.

The states of LEDs are listed below.

Table 26 Status and Meaning of Each LED (Power Supply Unit for the ETERNUS DX500 S5/DX600 S5/DX900
S5)
LED name LED status Meaning

POWER AC power is supplied to the power supply unit.


(green)

FAULT The power supply unit is in error status.


(amber)

236 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

■ Host Interface
A host interface is a board that has interface ports to connect a controller to the server.

● ETERNUS DX60 S5
There are five types of host interfaces: FC 16Gbit/s, FC 8Gbit/s, iSCSI 10Gbit/s, iSCSI 1Gbit/s, and SAS 12Gbit/s.

Figure 60 Host Interface Ports (ETERNUS DX60 S5)

FC
LINK/FAULT LED

iSCSI 10Gbit/s SAS 12Gbit/s


iSCSI 1Gbit/s
Port#0 Port#1 Port#0 Port#1

FAULT LED LINK/FAULT LED


LINK LED

The LEDs turn on or blink to indicate the statuses that are listed below.

Table 27 Status and Meaning of Each LED (Host Interface for the ETERNUS DX60 S5)
LED name LED status Meaning

LINK/FAULT The link between the host interface port (FC or SAS) and the
(green) destination port has been established.

The host interface port (FC or SAS) is in error status.


(amber)

FAULT The link between the host interface port (iSCSI) and the destination
(green) port has been established.

LINK The host interface port (iSCSI) is in error status.


(amber)

237 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

● ETERNUS DX100 S5/DX200 S5


There are nine types of host interfaces: FC 32Gbit/s, FC 16Gbit/s, iSCSI 10Gbit/s (10GBASE-SR/10GBASE-CR),
iSCSI 10Gbit/s (10GBASE-T), iSCSI 1Gbit/s, SAS 12Gbit/s, Ethernet 10Gbit/s, and Ethernet 1Gbit/s.

Figure 61 Host Interface Ports (ETERNUS DX100 S5/DX200 S5)

FC 2 ports
LINK/FAULT LED

FC 2 ports FC 4 ports
iSCSI 10Gbit/s (10GBASE-SR)

LINK/FAULT LED LINK/FAULT LED

iSCSI 10Gbit/s (10GBASE-CR) iSCSI 10Gbit/s (10GBASE-T)


Ethernet 10Gbit/s iSCSI 1Gbit/s
(for Copper Twinax cable connection)

LINK/FAULT LED LINK/FAULT LED

SAS 12Gbit/s Ethernet 1Gbit/s

LINK LED
LINK/FAULT LED FAULT LED

The LEDs turn on or blink to indicate the statuses that are listed below.

Table 28 Status and Meaning of Each LED (Host Interface for the ETERNUS DX100 S5/DX200 S5)

LED name LED status Meaning


LINK/FAULT The link between the host interface port (FC or SAS) and the
(green) destination port has been established.
The host interface port (FC or SAS) is in error status.
(amber)

238 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

LED name LED status Meaning


FAULT The link between the host interface port (iSCSI) and the
(green) destination port has been established.
LINK The host interface port (iSCSI) is in error status.
(amber)

● ETERNUS DX500 S5/DX600 S5


There are seven types of host interfaces: FC 32Gbit/s, FC 16Gbit/s, iSCSI 10Gbit/s (10GBASE-SR / 10GBASE-CR),
iSCSI 1Gbit/s, Ethernet 10Gbit/s, and Ethernet 1Gbit/s.

Figure 62 Host Interface Ports (ETERNUS DX500 S5/DX600 S5)


CA FAULT LED

CA READY LED

FC 2 ports FC 4 ports
iSCSI 10Gbit/s (10GBASE-SR)
LINK/FAULT LED LINK/FAULT LED

Port#0 Port#1 Port#0 Port#1 Port#2 Port#3

iSCSI 10Gbit/s (10GBASE-CR) iSCSI 1Gbit/s


Ethernet 10Gbit/s
(for Copper Twinax cable connection)
LINK/FAULT LED LINK/FAULT LED

Port#0 Port#1 Port#0 Port#1 Port#2 Port#3

Ethernet 1Gbit/s
LINK/FAULT LED

Port#0 Port#1 Port#2 Port#3

The states of LEDs are listed below.

Table 29 Status and Meaning of Each LED (Host Interface for the ETERNUS DX500 S5/DX600 S5)

LED name LED status Meaning


CA FAULT The host interface is in error status.
(amber)

CA READY The host interface is in normal status.


(green)

LINK/FAULT The link between the host interface port and the destination
(green) port has been established.
The host interface port is in error status.
(amber)

239 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

● ETERNUS DX900 S5
There are five types of host interfaces: FC 32Gbit/s, FC 16Gbit/s, iSCSI 10Gbit/s (10GBASE-SR/10GBASE-CR),
and iSCSI 1Gbit/s.

Figure 63 Host Interface (ETERNUS DX900 S5)


CA FAULT LED

CA READY LED

FC 2 ports
iSCSI 10Gbit/s (10GBASE-SR) FC 4 ports

LINK/FAULT LED LINK/FAULT LED

Port#0 Port#1 Port#0 Port#1 Port#2 Port#3

iSCSI 10Gbit/s (10GBASE-CR) iSCSI 1Gbit/s


LINK/FAULT LED LINK/FAULT LED

Port#0 Port#1 Port#0 Port#1

The states of LEDs are listed below.

Table 30 Status and Meaning of Each LED (Host Interface for the ETERNUS DX900 S5)

LED name LED status Meaning


CA FAULT The host interface is in error status.
(amber)

CA READY The host interface is in normal status.


(green)

LINK/FAULT The link between the host interface port and the destination
(green) port has been established.
The host interface port is in error status.
(amber)

240 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

■ PCIe Flash Modules (PFM)


A PCIe Flash Module (PFM) is a module that is installed to operate the Extreme Cache function.
1.6TB and 3.2TB PFM capacity options are available for Extreme Cache.
Up to eight PFMs can be installed in each controller. Slot 16 to Slot 23 are shared by the drives and the PFMs.
The maximum PFM capacity of each controller enclosure is 25.6TB.
A PFM has LEDs.

● ETERNUS DX500 S5/DX600 S5/DX900 S5

Figure 64 PFM
READY LED
FAULT LED

The LEDs turn on or blink to indicate the statuses that are listed below.

Table 31 Status and Meaning of Each LED (PFM)


LED name LED status Meaning

READY The PFM is in normal status.


(green)

The PFM is busy or temporarily unavailable.


(blinks green)

FAULT The PFM is in error status.


(amber)

241 Configuration Guide (Basic)


A. Component Names
Controller Enclosure

■ Batteries
Batteries are used for backup power source in case of power outage. A controller enclosure has two batteries.
The batteries are charged from an external power source while the ETERNUS DX is running normally. If a power
failure is detected, the cache data in the system memory is saved to the BUD in the controller by using battery
power. There is no limit to the post-failure data retention time.
Batteries for the ETERNUS DX500 S5/DX600 S5/DX900 S5 have LEDs.

● ETERNUS DX500 S5/DX600 S5/DX900 S5

Figure 65 Batteries

BRDY LED
CHG LED
BCA LED
BTA LED

The states of LEDs are listed below.

Table 32 Status and Meaning of Each LED (Battery)


LED name LED status Meaning

BRDY The battery charge rate is 90% or more.


(Battery Ready) (green)

CHG The battery is being charged or is ready for discharge.


(Charge) (green)

BCA The battery is in error status.


(BCU Alarm) (amber)

BTA The battery is in error status.


(BTU Alarm) (amber)

■ BUD
A BUD is non-volatile memory in which the firmware is registered. A BUD is used as an area to back up cache
data in the system memory if a power failure occurs.

242 Configuration Guide (Basic)


A. Component Names
Drive Enclosure

Drive Enclosure
Drives and an operation panel are installed in the front of the drive enclosure. I/O modules and power supply
units are installed in the rear.

Front
This section provides the names of the components in the front of a drive enclosure.

■ 2.5" Type

Figure 66 Front View of a 2.5" Type Drive Enclosure

1 2
Slot#10
Slot#11
Slot#12
Slot#13
Slot#14
Slot#15

Slot#16
Slot#17
Slot#18
Slot#19
Slot#20
Slot#21
Slot#22
Slot#23
Slot#0
Slot#1
Slot#2
Slot#3
Slot#4
Slot#5
Slot#6
Slot#7

Slot#8
Slot#9

3 3

1 Operation panel (refer to "■ Operation Panel" (page 248))


2 2.5" drive (refer to "■ Drives" (page 250))
3 Flange cover

■ 3.5" Type

Figure 67 Front View of a 3.5" Type Drive Enclosure

1 2

Slot#8 Slot#9 Slot#10 Slot#11

Slot#4 Slot#5 Slot#6 Slot#7

Slot#0 Slot#1 Slot#2 Slot#3

3 3

1 Operation panel (refer to "■ Operation Panel" (page 248))


2 3.5" drive (refer to "■ Drives" (page 250))
3 Flange cover

243 Configuration Guide (Basic)


A. Component Names
Drive Enclosure

■ High-Density Drive Enclosure

Figure 68 Front View of a High-Density Drive Enclosure

1 2 3

1 Operation panel (refer to "■ Operation Panel" (page 248))


2 Disk Activity Panel (DAP) (refer to "■ Disk Activity Panel (DAP) (for High-Density Drive Enclosure)" (page
249))
3 Front cover

244 Configuration Guide (Basic)


A.

1
Slot#0 Slot#12 Slot#24 Slot#36 Slot#48

1
Drive Enclosure

Figure 69

Slot#1 Slot#13 Slot#25 Slot#37 Slot#49


Component Names

Slot#2 Slot#14 Slot#26 Slot#38 Slot#50

Slot#3 Slot#15 Slot#27 Slot#39 Slot#51

Slot#4 Slot#16 Slot#28 Slot#40 Slot#52

Slot#5 Slot#17 Slot#29 Slot#41 Slot#53


Rear

Front
Slot#6 Slot#18 Slot#30 Slot#42 Slot#54

Slot#7 Slot#19 Slot#31 Slot#43 Slot#55

3.5" drive (refer to "■ Drives" (page 250))


Slot#8 Slot#20 Slot#32 Slot#44 Slot#56

245
Slot#9 Slot#21 Slot#33 Slot#45 Slot#57

Slot#10 Slot#22 Slot#34 Slot#46 Slot#58

Slot#11 Slot#23 Slot#35 Slot#47 Slot#59


Top View of a High-Density Drive Enclosure with the Cover Opened

Configuration Guide (Basic)


A. Component Names
Drive Enclosure

Rear
This section provides the names of the components on the rear of a drive enclosure.

■ 2.5" Type / 3.5" Type

Figure 70 Rear View of a 2.5"/3.5" Type Drive Enclosure (When Only One I/O Module Is Installed)

1 1

IOM#0

PSU#0 PSU#1

2 2

Figure 71 Rear View of a 2.5"/3.5" Type Drive Enclosure (When Two I/O Modules Are Installed)

1 1

IOM#0 IOM#1

PSU#0 PSU#1

2 2

1 I/O modules (IOM#0, IOM#1) (refer to "■ I/O Modules" (page 251))
2 Power supply units (PSU#0, PSU#1) (refer to "■ Power Supply Units" (page 252))

246 Configuration Guide (Basic)


A. Component Names
Drive Enclosure

■ High-Density Drive Enclosure

Figure 72 Rear View of a High-Density Drive Enclosure

1 IOM#0 IOM#1 1

2 PSU#2 PSU#3 2

2 PSU#0 PSU#1 2

3 FEM#0 FEM#1 3

1 I/O modules (IOM#0, IOM#1) (refer to "■ I/O Modules" (page 251))
2 Power supply units (PSU#0, PSU#1, PSU#2, PSU#3) (refer to "■ Power Supply Units" (page 252))
3 Fan expander modules (FEM#0, FEM#1) (refer to "■ Fan Expander Module (FEM)" (page 253))

247 Configuration Guide (Basic)


A. Component Names
Drive Enclosure

Component Names and LED Names


This section describes the operation panel, the drives, the I/O modules, and the power supply units of the drive
enclosure.

■ Operation Panel
An operation panel has a DE-ID display and LEDs.

● Drive Enclosure

Figure 73 Operation Panel (Drive Enclosure)

IDENTIFY LED FAULT LED

POWER LED

1 DE-ID
The DE-ID (drive enclosure number) of the drive enclosure is displayed.

The LEDs turn on or blink to indicate the statuses that are listed below.

Table 33 Status and Meaning of Each LED (Operation Panel [Drive Enclosure])
LED name LED status Meaning

IDENTIFY The installation location of the drive enclosure is identified according


(blinks blue) to the instruction that is issued from ETERNUS Web GUI or ETERNUS
CLI.

FAULT The drive enclosure is in error status.


(amber)

POWER DC power is supplied to the drive enclosure.


(green)

248 Configuration Guide (Basic)


A. Component Names
Drive Enclosure

■ Disk Activity Panel (DAP) (for High-Density Drive Enclosure)


The Disk Activity Panel (DAP) has a Slot No. LED for each drive.

Figure 74 Disk Activity Panel (DAP)

Slot No. LED

The LEDs turn on or blink to indicate the statuses that are listed below.

Table 34 Status and Meaning of Each LED (Disk Activity Panel [DAP])
LED name LED status Meaning

Slot No. The drive is in normal status.


(green)

(blinks green)

• The drive is in error status.


(amber) • The LED light up operation was performed from the ETERNUS CLI
command line in order to identify the drive location.

249 Configuration Guide (Basic)


A. Component Names
Drive Enclosure

■ Drives
2.5" drives and 3.5" drives have LEDs.

Figure 75 2.5" Drives and 3.5" Drives


2.5" drive 3.5" drive Drive for high-density drive enclosure
DRIVE READY LED
DRIVE FAULT LED
DRIVE READY LED

DRIVE FAULT LED

The LEDs turn on or blink to indicate the statuses that are listed below.

Table 35 Status and Meaning of Each LED (Drive)


LED name LED status Meaning

DRIVE READY The drive is in normal status.


(green)

(blinks green)

DRIVE FAULT • The drive is in error status.


(amber) • The LED light up operation was performed from the ETERNUS CLI
command line in order to identify the drive location.

250 Configuration Guide (Basic)


A. Component Names
Drive Enclosure

■ I/O Modules
The I/O module is a component that controls how the controller and the drives interact.
The I/O module is connected to the controller or an I/O module on another drive enclosure. A drive enclosure has
two I/O modules.
I/O modules have ports and LEDs.

Figure 76 I/O Module (Drive Enclosure)

1 2
DI (IN) LINK LED DI (OUT) LINK LED READY LED

DI (IN) FAULT LED DI (OUT) FAULT LED IDENTIFY LED


FAULT LED

1 DI (IN) port
This port is used to connect between enclosures.
2 DI (OUT) port
This port is used to connect between enclosures.

The LEDs turn on or blink to indicate the statuses that are listed below.

Table 36 Status and Meaning of Each LED (I/O Module [Drive Enclosure])
LED name LED status Meaning

DI (IN) LINK The link between the DI (IN) port and the source port has been
(green) established.

DI (IN) FAULT • The ports to remove the cables between enclosures from are
(amber) indicated. This occurs while a drive enclosure is being added.
• The link between the DI (IN) port and the source port is in error
status.

The ports to connect the cables are indicated. This occurs while a
(blinks amber) drive enclosure is being added.

DI (OUT) LINK The link between the DI (OUT) port and the destination port has been
(green) established.

DI (OUT) FAULT The link between the DI (OUT) port and the destination port is in
(amber) error status.

The ports to connect the cables are indicated. This occurs while a
(blinks amber) drive enclosure is being added.

READY The I/O module is in normal status.


(green)

IDENTIFY The installation location of the I/O module is identified according to


(blinks blue) the instruction that is issued from ETERNUS Web GUI or ETERNUS CLI.

FAULT The I/O module is in error status.


(amber)

251 Configuration Guide (Basic)


A. Component Names
Drive Enclosure

■ Power Supply Units


There are two types of the power supply units: AC power type and DC power type. The AC power type power
supply unit converts input power from a power socket to DC power and supplies power to each component.
A drive enclosure has two power supply units.
Each power supply unit contains fans.

Figure 77 Power Supply Unit (Drive Enclosure) (AC Power Type)

POWER LED FAN FAIL LED


FAULT LED AC MISSING LED 1 2

Figure 78 Power Supply Unit (Drive Enclosure) (DC Power Type)

POWER LED FAN FAIL LED


FAULT LED AC MISSING LED
2

1 PSU switch
This switch is used to turn on and off the power supply.
2 Inlet
This inlet is used to connect a power cord.

The LEDs turn on or blink to indicate the statuses that are listed below.

Table 37 Status and Meaning of Each LED (Power Supply Unit (Drive Enclosure))
LED name LED status Meaning

POWER Power is supplied to the power supply unit.


(green)

Power is supplied to the power supply unit, but DC power is not


(blinks green) supplied to the ETERNUS DX.

FAULT Power is not supplied to the power supply unit.


(amber)

AC MISSING Power is not supplied to this power supply unit, but power is supplied
(amber) to the other power supply unit.

FAN FAIL The power supply unit or the fan in the power supply unit is in error
(amber) status.

252 Configuration Guide (Basic)


A. Component Names
Drive Enclosure

■ Fan Expander Module (FEM)


A Fan Expander Module (FEM) is a cooling fan module.
Two FEMs are installed in a high-density drive enclosure.
If one of the FEMs fails, the failed FEM can be replaced while the system is running.

Figure 79 Fan Expander Module

READY LED
FAULT LED
IDENTIFY LED

The LEDs turn on or blink to indicate the statuses that are listed below.

Table 38 Status and Meaning of Each LED (Fan Expander Module)


LED name LED status Meaning

READY The fan expander module is in normal status.


(green)

FAULT The fan expander module is in error status.


(amber)

IDENTIFY The installation location of the fan expander module is identified


(blinks blue) according to the instruction that is issued from ETERNUS Web GUI or
ETERNUS CLI.

253 Configuration Guide (Basic)


A. Component Names
Power Distribution Unit

Power Distribution Unit


There are two sizes for power distribution units: 1U and 2U.

Power Distribution Units (1U)


The 1U power distribution unit has four outlets and two inlets.

Figure 80 Power Distribution Units (1U)

2
3

1 Main line switch


This turns on and off the power distribution unit.
2 Outlet (OUTPUT)
This is a socket (IEC60320 C13) for outgoing power supply. This socket is used to connect a power cord (AC
output cable).
3 Inlet (INPUT)
This is a socket (IEC60320 C14) for incoming power supply. This socket is used to connect a power cord (AC
input cable).

Power Distribution Units (2U)


The 2U power distribution unit has 16 outlets.

Figure 81 Power Distribution Units (2U)

1 1

1 Main line switch


This turns on and off the power distribution unit.
2 Outlet (OUTPUT)
This is a socket (IEC60320 C13) for outgoing power supply. This socket is used to connect a power cord (AC
output cable).

254 Configuration Guide (Basic)


B. Structures for Host Connection
This appendix describes structures for host connection.
• Host group
A host group is a group of hosts that is allowed to access the volume (LUN group).
By configuring the host group, the LUN mapping settings or host response settings for the hosts in the host
group can be changed with a single operation.
• CA port group
A CA port group is a group of host interface ports that is allowed to access the volume (LUN group).
By configuring the port group, the LUN mapping settings for the host interface ports in the port group can be
changed with a single operation. CA port groups can be used to configure a multipath or a host cluster.
• LUN group
A LUN group is a group of volumes that allows access from the host.
A host LUN, which is an identifier from the host, is assigned to each volume in the LUN group.
• Host affinity
For the host, host affinity is a function that controls access permissions to volumes.
• Host affinity setting
The host affinity setting is an operation that assigns hosts (host groups) or ports (port groups) to LUN groups.

Figure 82 Basic Concept of Host Connection (When Using Host Groups)

Host Group A

Host A ETERNUS DX

Multipath
HBA1
HBA2
Switch CA Port Group X LUN Group XX

Host Group B Port #0

Host B Switch Vol#1 Vol#2 Vol#3


Port #1

HBA1
Multipath
HBA2

Host Group C

Host C CA Port Group Y LUN Group YY

Multipath
HBA1 Port #2
Switch Vol#10 Vol#11
HBA2
Port #3
Host D

Switch
HBA1
Multipath
HBA2 The procedure to define the Host Affinity is as follows:
1. Define host group.
2. Define CA port group.
3. Define LUN group.
4. Allocate the host group, the CA port group, and the LUN group.

255 Configuration Guide (Basic)


B. Structures for Host Connection

■ Configuration Example
● Host Group Settings
Refer to "Add FC Host Group" or "Add iSCSI Host Group" in "ETERNUS Web GUI User's Guide" for details.

No. Host Group Host Host response


1 Host Group A Host A – HBA1 Default
Host A – HBA2
2 Host Group B Host B – HBA1 Default
Host B – HBA2
3 Host Group C Host C – HBA1 Default
Host C – HBA2
Host D – HBA1
Host D – HBA2

● CA Port Group Creation


Refer to "Create FC Port Group" or "Create iSCSI Port Group" in "ETERNUS Web GUI User's Guide" for details.

No. CA Port Group Port


1 CA Port Group X Port#0, Port#1
2 CA Port Group Y Port#2, Port#3

Port#0: CM#0 CA#0 Port#0


Port#1: CM#1 CA#0 Port#0
Port#2: CM#0 CA#0 Port#1
Port#3: CM#1 CA#0 Port#1

● LUN Group Settings


Refer to "Add LUN Group" in "ETERNUS Web GUI User's Guide" for details.

No. LUN host group Host LUN LUN


1 LUN Group XX 0 Vol#1
1 Vol#2
2 Vol#3
2 LUN Group YY 0 Vol#10
1 Vol#11

● Host Affinity Creation


Refer to "Create Host Affinity" in "ETERNUS Web GUI User's Guide" for details.

No. Host group CA port group LUN group Description


1 Host Group A CA Port Group X LUN Group XX A host affinity with the affinity
(Default) mode set to "ON".
2 Host Group B CA Port Group X LUN Group XX A host affinity with the affinity
(Default) mode set to "ON".
3 (*1) Host Group C CA Port Group Y LUN Group YY A host affinity with the affinity
(Default) mode set to "ON".

256 Configuration Guide (Basic)


B. Structures for Host Connection

No. Host group CA port group LUN group Description


4 (*2) All (Default) CA Port Group Y LUN Group YY A host affinity with the affinity
mode set to "OFF".

*1: Setting example when specifying a host group that accesses LUN Group YY via CA Port Group Y.
*2: Setting example when a host group that accesses LUN Group YY via CA Port Group Y is not specified.

Caution
• In setting example No.4, LUN groups other than "LUN Group YY" cannot be allocated to the "CA Port
Group Y".
• The "CA Port Group Y" for which "All" is selected is already allocated to all the hosts. Therefore, the
"CA Port Group Y" cannot be allocated to the specific host group. (Setting examples No.3 and No.4
cannot be configured in the same environment.)

257 Configuration Guide (Basic)


FUJITSU Storage ETERNUS DX S5 series Hybrid Storage Systems
Configuration Guide (Basic)
P3AG-3982-04ENZ0

Date of issuance: October 2020


Issuance responsibility: FUJITSU LIMITED

• The content of this manual is subject to change without notice.


• This manual was prepared with the utmost attention to detail.
However, Fujitsu shall assume no responsibility for any operational problems as the result of errors, omissions, or the
use of information in this manual.
• Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information
in this manual.
• The content of this manual may not be reproduced or distributed in part or in its entirety without prior permission from
Fujitsu.

You might also like