iFlash Test Panels S p e ci fic a t ions Y#ILO

Main Stream Reproductive General Information


Autoimmunity Infection
Hormonology Health Throughput Up to 180 t ests/ hour
Fastest time to first result 12 minutes
Detection principle Magnetic particle-based direct chemiluminescence
Thyroid Fertility Rheumatoid Arthritis EBV
TSH AMH Anti-CCP EBVCAlgG Chemiluminescence label Acridinium Ester
Anti-TPO lnhibin B RFlgG EBVCAlgM
Sample Supply System
Anti-TSHR lnhibin A RFlgM EBVCAlgA
Tg LH RF EB EAlgM Sam pie position 5 samples per rack , 50 sample positions with STAT function
Anti-Tg FSH RA33 lgG EB NAlgG Sam pie volume 5-150µL
FT3 HCG EB NA lgA Reaction vessels loader capacity 1000 reaction vessels reserve for continuous loading
FT4 Prolactin Connective Tissue
T3 DHEA-S Disease Respiratory Disease Reagent System
T4 Unconjugated Estriol ANA Mycoplasma pn. lgG
Reagent position 20 positions with onboard refrigeration
E2 dsDNA lgG Mycoplasma pn. lgM
Reagent carousel temperature 2-8°C
Tumor Markers PAPP-A SmlgG Chlamydia pn. lgG
Reagent detection Reagent level tracking
PG 1 free BHCG SS-A lgG Chlamydia pn. lgM
PG Il Progesterone SS-B lgG Reagent pack 2x50 tests per kit
AFP Testosterone Scl-70 lgG Blood Bank Auto dilution Maximum of 1 :400
CEA Jo-1 lgG Anti-TP
CA 125 ToRCH RNP70 lgG Anti-HCV* Reaction Carousel
CA 15-3 Toxo lgG HBsAg * Capacity 75 reaction vessels
CA 19-9 Toxo lgM Autoimmune Liver Anti-HBs * Incubation temperature 37.0°C ± 0.3°C, with a fluctuation of 0.1 °C
Free PSA CMVlgG SMA lgG HBeAg * Mixing system Non-cont act eccentric vortex mixer
Total PSA CMVlgM AMA-M2 Anti-HBe *
CYFRA21-1 HSV-1 lgG Anti-HBc * Magnetic Separation System
NSE HSV-2 lgG Vasculitis Diagnostics HIVCombo*
Washing method 4-step magnetic separation
HSV-1 lgM PR3 lgG
Anemia HSV-2 lgM GBM lgG Inflammation Temp erature 37.0°C ± 0.3°C, with a fluctuation of 0 .1°C
Ferritin Rubella lgG MPO lgG PCT
Folate Rubella lgM Operating Conditions
Vitamin B12 Autoimmune Diabetes Novel Coronavirus Power supply 100-240 V, 50/60 Hz
Anti-Phospholipid IA-2A SARS-CoV-2 lgM Power consumption 1000 VA
Cardiac Markers Syndrome IAA SARS-CoV-2 lgG Temperature 10-3 0°C
CK- MB Anti-Cardiolipin GADA Ambient humidity 20 %-70% RH
Myoglobin Cardiolipin lgM ICA Physical dimensions 1030 mm (L) x 750 mm (W) x 710 mm (H)
Troponin-I Cardiolipin lgG ZnTBA
Weight 150 kg
BNP Cardiolipin lgA
Anti- B 2-Glycoprotein 1
Bone Metabolism B 2-Glycoprotein l lgM
25 -OH Vitamin D B 2-Glycoprotein l lgG
PTH B 2-Glycoprotein l lgA

Metabolism
lnsulin
• Without CE
C-Peptide
,----------------------- ' iflash 11800
Cortisol
ACTH
Adiponect in

Liver Fibrosis
ooc 1 Local Distributor:

, _______________________ ;
1
Y#ILO
SHENZHEN YHLO BIOTECH CO., LTD.

Head quarter: Building 1, YHLO Biopark, Baolong 2"' Road,


YHLD
- iFb,h-,
Chemiluminescence
lmmunoassay Analyzer
D
Baolong Subdistrict , Longgang Dist rict , 5 1 B11 6 Shenzhen, P.R.Chlna

·-
HA
Co nsol idation for Automation
PIII PN-P
Col IV
Laminin
0 P/N: ENG-C003-202003
CE SS
Tel: + 86 755 26601910
Email: marketing@szyhlo.com
W ebsite: www.szyhlo.com

0 1
Onn
YHLO

iflash 11800
Chemiluminescence lmmunoassay Analyzer
Reaction vessel loading container simplifies vessel loading
Consolidation for Automation process and redu ces manual handling time.
0

iFlash 1800 is a bench-top solution


tailored for clinical labs. With less
Special RV array design allows for accurate reaction vessel
outsourced samples, improved in-house
placement and avoids potential blockage.
controlled quality and higher throughput,
0
iFlash 1800 has achieved better efficiency
and reliability.

lndependent reaction vessel gripper guarantees precise


-
vesse! handling.
0

YHLO High-capacity reagent carousel provides longer onboard


reagent stability. AMH AMH ~
lilill 20170401 iMl 20170401 j~ -

=
-
D 20130411 U 20180417 @21 ~
Yttl.D $ i '!z-

Non- contact vortex mixer design avoids liquid touching and


eliminates the chance of cross contamination.

Consolidating various workstat ion


on a CLIA platform for differential di agnosis
iFlash 1800 delivers unmatched, innovative and comprehensive product
assortment for quick clin ical diagnosis, including reproductive health,
auto immuni t y, diabe t es, in f ec tious d iseases and o th e r routine
A CLIA system with better efficiency compared toits peers Reliable and consistent performance via state-of-art design parameters.

• Compact design with 180 tests per hour maximum throughput, delivers more sample results per square meter. We paid attention to every detail when designing the iFlash 1800 analyzers and its reagents. We are dedicated to • Comprehensive panel of 11 2 parameters: less analyzer, less sample
• 1000 reaction vessais on-board, 50 sample positions and 20 reagent positions, ensure less restocking cycles. produce a reli ab le immunoassay system to the labs. splitting and better quality cont rai within the lab.
• Continuo us loading of samples, reagents and consumables provides less interruption of analytical phase. • Unique parameters on CLIA platform ensures less outsourcing and
• Reflex, auto dilution and auto rerun function can save time for lab technicians. co nsolidated result s output.