EM 222 DIGITAL OUTPUT

Overview

Digital outputs in addition to the on-board I/Os of the CPUs

Application

Digital output modules can be used to output digital signals from the control to the process.

Function

Digital output modules convert the internal signal level of the S7-200 in the external signal level required
for the process.

Technical specifications

Page 321 Mar 2008 Siemens ITS


Technical specifications

6ES7 222-1BD22- 6ES7 222-1BF22-


0XA0 0XA0
Supply voltage
Load voltage L+
•Rated value (DC) 24 V 24 V
•permissible range, lower limit 20.4 V 20.4 V
(DC)

Page 322 Mar 2008 Siemens ITS


•permissible range, upper limit 28.8 V 28.8 V
(DC)
Input current
from backplane bus 5 V DC, 40 mA 50 mA
max.
Power losses
Power loss, typ. 3W 2W
Digital outputs
Number/binary outputs 4 8
Functionality/short-circuit strength No No; to be provided
externally (see manual
package "Setting up
an S7-200")
Limitation of inductive shutdown L+ (-48 V) L+ (-48 V)
voltage to
Output voltage
•for signal "1", min. 20 V DC 20 V
Output current
•for signal "1" permissible range 5A 750 mA
for 0 to 55 °C, max.
•for signal "0" residual current, 30 µA 10 µA
max.
Page 323 Mar 2008 Siemens ITS
Parallel switching of 2 outputs
•for increased power Yes
Aggregate current of outputs (per
group)
20 A 3A
• up to 40 °C, max.
5A 3A
• maximum current per
conductor/group
•horizontal installation
20 A 3A
• up to 55 °C, max.
Cable length
•Cable length, shielded, max. 500 m 500 m
•Cable length unshielded, max. 150 m 150 m
Relay outputs
Switching capacity of contacts
•with inductive load, max. 5A 0.75 A
•on lamp load, max. 50 W 5W
•Switching frequency/contacts/at 5A 0.75 A
ohmic load/maximum
Galvanic isolation
Galvanic
Page 324isolation digital outputs Mar 2008 Siemens ITS
•Galvanic isolation digital outputs Yes Yes; Optocoupler
•between the channels, in groups 1 4
of
Connection method
Plug-in I/O terminals Yes Yes
Dimensions
Width 45 mm 45 mm
Height 80 mm 80 mm
Depth 62 mm 62 mm
Weight
Weight, approx. 120 g 150 g
6ES7 222-1HD22- 6ES7 222-1HF22- 6ES7 222-1EF22-
0XA0 0XA0 0XA0
Supply voltage
Load voltage L+
•Rated value (DC) 24 V 24 V
•permissible range, 12 V 5V
lower limit (DC)
•permissible range, 30 V 30 V
upper limit (DC)
Load voltage L1
•Rated value (AC) 24 V; 24 to 230 V 24 V; 24 to 230 V 230 V; 220/230 V AC
Page 325 AC Mar AC
2008 Siemens ITS
•permissible range, 12 V 5V 65 V
lower limit (AC)
•permissible range, 250 V 250 V 264 V
upper limit (AC)
•permissible 47 Hz 47 Hz
frequency range,
lower limit
•permissible 63 Hz 63 Hz
frequency range,
upper limit
Input current
from backplane bus 5 30 mA 40 mA 110 mA
V DC, max.
Digital outputs
•from load voltage 80 mA; 20 mA per 72 mA; 9 mA per
L+, max. switched output switched output
Power losses
Power loss, typ. 4W 2W 4W
Digital outputs
Number/binary 4; Relay 8; Relay 8
outputs
Functionality/short- No; to be provided No; to be provided No; to be provided
circuit strength externally (see externally (see externally (see manual
Page 326 manual package Marmanual
2008 package package "Setting
Siemensup
ITSan
"Setting up an S7- "Setting up an S7- S7-200")
200") 200")
Limitation of to be provided to be provided to be provided
inductive shutdown externally (see externally (see externally (see manual
voltage to manual package manual package package "Setting up an
"Setting up an S7- "Setting up an S7- S7-200")
200") 200")
Output voltage
•for signal "1", min. L1 (-0.9 V)
Output current
•for signal "1" 10 A 2A 500 mA; AC
permissible range for
0 to 55 °C, max.
•for signal "1" 50 mA
minimum load current
•for signal "0" 0 mA 0 mA 1.8 mA; at 264 V AC
residual current, max.
Aggregate current of
outputs (per group)
40 A 8A 0.5 A
• up to 40 °C,
Page max.
327 Mar 2008 Siemens ITS
10 A 8A 0.5 A
• maximum
current per
conductor/grou
p
•horizontal installation
20 A 8A 0.5 A
• up to 55 °C,
max.
Cable length
•Cable length, 500 m 500 m 500 m
shielded, max.
•Cable length 150 m 150 m 150 m
unshielded, max.
Relay outputs
Number of operating 30 000 000; 10 000 000;
cycles mechanically 30 mechanically 10
million, at rated load million, at rated
voltage 30,000 load voltage
100,000
Switching capacity of
contacts
•with inductive load, 3 A; 2 A (DC), 3 A 2 A 0.5 A
max.
Page 328 (AC) Mar 2008 Siemens ITS
•on lamp load, max. 1 000 W; 100/1000 200 W; 30 W DC; 60 W
W (DC/AC) 200 W AC
•Switching 10 A 2A 0.5 A
frequency/contacts/at
ohmic load/maximum
Galvanic isolation
Galvanic isolation
digital outputs
•Galvanic isolation Yes; Relay Yes; Relay Yes; Optocoupler
digital outputs
•between the 1; 4 groups 4 1; 8 groups
channels, in groups
of
Connection method
Plug-in I/O terminals Yes Yes Yes
Dimensions
Width 45 mm 45 mm 71.2 mm
Height 80 mm 80 mm 80 mm
Depth 62 mm 62 mm 62 mm
Weight
Weight, approx.
Page 329 150 g Mar170
2008g 170 g Siemens ITS