Dental Implant System

Esthetic & Innovation

SHINSAEGI MEDI-TECH Co., Ltd.


SHINSAEGI MEDI-TECH
1
CONTENTS

03 View of company
04 Work Flow Concept of CAD/CAM System
05 Packing design Un-packing Protocol
06 ALIA Locking Abutment ALIPS Locking Abutment Screw
07 Mountless driver system Length of the implant(EST, SST, IST, IT)
08 Introduction of SG Implant
11 EST System
- External Slightly Tapered Fixture(EST)
- Prosthetic Flow diagrams and components for Cemented Abutment, Angled Abutment,
UCLA Gold Abutment, UCLA Plastic Abutment, Temporary Abutment.
- Prosthetic Flow diagrams and components for Estheticone, Midicone, Widecone,
Locking Abutment.
- Prosthetic Flow diagrams and components for O-Ring Abutment.

29 SST System
- Internal Submerged Slightly Tapered Fixture(SST)
- Prosthetic Flow diagrams and components for Sub-Solid Abutment.
- Prosthetic Flow diagrams and components for Sub-Cemented Abutment, Sub-Angled Abutment,
Sub-Temporary Abutment, Sub-Gold Abutment.
- Prosthetic Flow diagrams and components for Sub-Locking Abutment.
- Prosthetic Flow diagrams and components for Sub-O-Ring Abutment.

43 IST System
- Internal Slightly Tapered Fixture(IST)

47 IT System
- Internal Tapered Fixture(IT)
- Prosthetic Flow diagrams and components for Solid Abutment, Excellent Solid Abutment.
- Prosthetic Flow diagrams and components for In-Octa Cemented Abutment, In-Octa Gold Abutment,
Solid Angled Abutment, In-Octa Locking Abutment.
- Prosthetic Flow diagrams and components for Octa Abutment.
- Prosthetic Flow diagrams and components for O-Ring Abutment.
65 Surgical Instrument
- Surgical Instrument for EST, SST, IST, IT
- Drill system
- Surgical Drilling protocol and Dimensions
- Surgical protocol for EST, SST, IST, IT
- Surgical kit contents

02 SHINSAEGI MEDI-TECH
View of company

Company : SHINSAEGI Medi-Tech Co., Ltd.

Head office & Manufacture Address :


Busan-city, Gang Seu-Gu, Ji Sa-Dong 1212, Korea
TEL : 82-51-971-2811 FAX : 82-51-971-2814
E-mail : sgimplant@sgimplant.com
Homepage : http://sgimplant.com

Business : Medical Instrument Manufacture & Marketing

Product :
Dental Implant (Manufacture&Marketing )
Dental CAD/CAM ( Manufacture&Marketing)
Titanium & Stainless ( Import & Marketing )
Dental Materials & Instrument ( Manufacture & Marketing)

SHINSAEGI MEDI-TECH
03
Work Flow Concept of CAD/CAM System

Preparation Model Preparation Scanning

Sintering Milling M/C Design

Veneering Cementation Scanning

04 SHINSAEGI MEDI-TECH
Packing design

This Ampule has been divided color for easy


Narrow(Red) Regular(Yellow) Wide(Green) Wide 6.0(Blue)

Narrow Regular Wide Wide 6.0

Implant Un-packing Protocol

1
Remove
2
Peel back the
3
Draw open a
4
Pick-up the
5
Mountless
contents from tray lid to expose cover of implant. implant from the delivery system
the implant the implant. surgical ampule for easy and
box. using the fixture safety.
mount driver.

SHINSAEGI MEDI-TECH
05
ALIA Locking Abutment
This innovate Locking Abutment released from Screw loosening. [ Patent No. US 7.393.210 B2 ]

External Hex Type Submerged Internal Hex Type Internal Octa Type
(EST) (SST) (IST&IT)

ALIPS Locking Abutment Screw


ALIPS (Anti Lock Inner Post Screw) [ Patent No. US 6.857.874 B2 ]

External Hex Type Submerged Internal Hex Type Internal Octa Type
(EST) (SST) (IST&IT)

06 SHINSAEGI MEDI-TECH
Mountless driver system

Pick-up and delivery of implant

External Hex Type Submerged Internal Hex Type Internal Octa Type
(EST) (SST) (IST&IT)

- Care must be taken when inserting the implant placement driver tip into the implant.
- A very low RPM speed must be used as you approach the internal hex and octa connection and external hex
connection of the implant with the driver tip.

Length of the implant(EST, SST, IST, IT)

1.8 mm
0.75 mm

Length(L)
7, 9, 11, 13, 15mm

EST SST IST IT

- Regardless of the implant type, the length of the implant is the same from the top of the implant
collar(platform) to the tip of the implant.

SHINSAEGI MEDI-TECH
07
Introduction of SG Implant

External Slightly Tapered Fixture (EST)

H
Size (mm)
No Code Diameter Diameter Length Hex Apex
D0 D1 L0 H A
D0
1 EFSN309 3.5 3.4 9.0 2.4 2.2
2 EFSN311 3.5 3.4 11.0 2.4 2.2
3 EFSN313 3.5 3.4 13.0 2.4 2.2
4 EFSN315 3.5 3.4 15.0 2.4 2.2
L0
5 EFSR407 4.1 4.0 7.0 2.7 2.6
6 EFSR409 4.1 4.0 9.0 2.7 2.6
7 EFSR411 4.1 4.0 11.0 2.7 2.6
8 EFSR413 4.1 4.0 13.0 2.7 2.6
A
9 EFSR415 4.1 4.0 15.0 2.7 2.6
D1
10 EFSW507 5.1 5.0 7.0 3.4 3.4
11 EFSW509 5.1 5.0 9.0 3.4 3.4
12 EFSW511 5.1 5.0 11.0 3.4 3.4
13 EFSW513 5.1 5.0 13.0 3.4 3.4
14 EFSW515 5.1 5.0 15.0 3.4 3.4

15 EFSW607 5.1 5.9 7.0 3.4 4.5


16 EFSW609 5.1 5.9 9.0 3.4 4.5
17 EFSW611 5.1 5.9 11.0 3.4 4.5
18 EFSW613 5.1 5.9 13.0 3.4 4.5

Submerged Slightly Tapered Fixture(SST)

H
Size (mm)
No Code Diameter Diameter Length Hex Apex
D0 D1 L0 H A
D0
1 SFSN309 3.8 3.75 9.0 2.5 2.2
2 SFSN311 3.8 3.75 11.0 2.5 2.2
3 SFSN313 3.8 3.75 13.0 2.5 2.2
4 SFSN315 3.8 3.75 15.0 2.5 2.2
L0
5 SFSR407 4.3 4.2 7.0 2.5 2.9
6 SFSR409 4.3 4.2 9.0 2.5 2.9
7 SFSR411 4.3 4.2 11.0 2.5 2.9
A 8 SFSR413 4.3 4.2 13.0 2.5 2.9
9 SFSR415 4.3 4.2 15.0 2.5 2.9
D1

10 SFSW507 5.0 4.9 7.0 2.5 3.6


11 SFSW509 5.0 4.9 9.0 2.5 3.6
12 SFSW511 5.0 4.9 11.0 2.5 3.6
13 SFSW513 5.0 4.9 13.0 2.5 3.6
14 SFSW515 5.0 4.9 15.0 2.5 3.6

15 SFSW607 6.0 5.9 7.0 2.5 4.3


16 SFSW609 6.0 5.9 9.0 2.5 4.3
17 SFSW611 6.0 5.9 11.0 2.5 4.3
18 SFSW613 6.0 5.9 13.0 2.5 4.3

08 SHINSAEGI MEDI-TECH
Introduction of SG Implant

Internal Slightly Tapered Fixture(IST)

O
Size (mm)
No Code Diameter Diameter Length Octa Apex
D0 D1 L0 O A
D0
1 IFSR407 4.8 4.1 7.0 3.1 2.4
2 IFSR409 4.8 4.1 9.0 3.1 2.4
1.8
3 IFSR411 4.8 4.1 11.0 3.1 2.4
4 IFSR413 4.8 4.1 13.0 3.1 2.4
5 IFSR415 4.8 4.1 15.0 3.1 2.4
L0
6 IFSW507 4.8 4.8 7.0 3.1 2.6
7 IFSW509 4.8 4.8 9.0 3.1 2.6
8 IFSW511 4.8 4.8 11.0 3.1 2.6
A
9 IFSW513 4.8 4.8 13.0 3.1 2.6
D1 10 IFSW515 4.8 4.8 15.0 3.1 2.6

11 IFSW607 6.0 5.3 7.0 3.1 4.0


12 IFSW609 6.0 5.3 9.0 3.1 4.0
13 IFSW611 6.0 5.3 11.0 3.1 4.0
14 IFSW613 6.0 5.3 13.0 3.1 4.0

Internal Tapered Fixture(IT)

O
Size (mm)
No Code Diameter Diameter Length Octa Apex
D0 D1 L0 O A
D0
1 IFTR407 4.8 4.1 7.0 3.1 2.4
2 IFTR409 4.8 4.1 9.0 3.1 2.4
1.8
3 IFTR411 4.8 4.1 11.0 3.1 2.4
4 IFTR413 4.8 4.1 13.0 3.1 2.4
5 IFTR415 4.8 4.1 15.0 3.1 2.4
L0
6 IFTW507 4.8 4.8 7.0 3.1 3.1
7 IFTW509 4.8 4.8 9.0 3.1 3.1
8 IFTW511 4.8 4.8 11.0 3.1 3.1
A
9 IFTW513 4.8 4.8 13.0 3.1 3.1
D1 10 IFTW515 4.8 4.8 15.0 3.1 3.1

11 IFTW607 6.0 5.3 7.0 3.1 3.6


12 IFTW609 6.0 5.3 9.0 3.1 3.6
13 IFTW611 6.0 5.3 11.0 3.1 3.6
14 IFTW613 6.0 5.3 13.0 3.1 3.6

SHINSAEGI MEDI-TECH
09
10 SHINSAEGI MEDI-TECH
External
Fixture
Esthetic & Innovation

SHINSAEGI MEDI-TECH
SHINSAEGI MEDI-TECH
11
EST System

01 Cover Screw 16p


Headless Cover Screw 16p
Healing Abutment 16p
02 Cemented Abutment 17p
Cemented Abutment T-Type 17p
Cemented Abutment Screw 17p
Cemented Abutment Screw (T-Type) 18p
ALIPS Locking Abutment Screw 18p
Fixture Lab Analog(UCLA) 18p
03 Angled Abutment 18p
Angled Abutment Screw 19p
04 UCLA Gold Abutment 19p
05 UCLA Plastic Abutment 19p
06 UCLA Temporary Abutment 19p
07 Impression Coping(Pick-up) 20p
Guide Pin(Pick-up) 20p
Impression Coping(Transfer) 20p
Guide Pin(Transfer) 20p
08 Conical Abutment 22p
Conical Abutment Screw 22p
Conical Healing Cap 22p
Conical Gold Cylinder 22p
Conical Plastic Cylinder 23p
Conical Temporary Cylinder 23p
Conical Cylinder Screw 23p
Conical Impression Coping(pick-up) 23p
Conical Guide Pin(pick-up) 24p
Conical Impression Coping (Transfer) 24p
Conical Lab Analog 24p
09 ALIA External Locking Abutment (Hex) 24p
External Locking Abutment Screw 25p
External YK Transfer Adapter 25p
External YK Transfer Screw 25p
Impression Plastic Cap 25p
External Locking Lab Analog 25p
10 O-Ring Abutment 27p
O-Ring 27p
O-Ring Retainer 27p
O-Ring Lab Analog 27p

12 SHINSAEGI MEDI-TECH
EXTERNAL (EST)
External Slightly Tapered Fixture(EST System)
EST Implant components and Branemark, 3i, implant components are fully interchangeable.

The inner of head Body of head

SUBMERGED (SST)
External Hex connection Flapless surgery
Hex height-0.75mm - Head design is the same
diameter as the implant body
- This implant ideal for surgery
No counter sinking
- This makes the surgical
procedure faster and simple.
Micro groove

INTERNAL (IST.IT)
- Acheive both soft and hard
tissue attachement
- Generate strong attachment
of cortical bone
- Superior primary stability

Apex

Body design
INTERNAL (IST.IT)

Sharp tip on 3-cutting edge


-This sharp tip also secures a
smooth insertion without the
implant wobbling Slightly taper
-Implant will not spin and loss -This design for increased initial
stablity when a higher density stablity in soft bone
area in reached
-This thread design make the Unique grooves
implant a very efficient -Increase stability compared to
selftapping unit. "v"type thread implant

SHINSAEGI MEDI-TECH
13
External Slightly Tapered Fixture (EST System)

Feature - Submerged External hex connection (Hex height 2.7mm)


- Apex size : Narrow( 2.2mm), Regular( 2.6mm), Wide( 3.4mm), Wide6.0( 4.5mm)
- Torque recommendation : 40Ncm

Narrow EST System Unit : mm


Platform Head Body
D1 Hex Length
|| Diameter Diameter Diameter Code
D0 (H) (L)
(D0) (D1) (D2)
9 EFSN309
11 EFSN311
3.5 3.5 3.4 2.4
L 13 EFSN313
15 EFSN315
Hex

D2

Regular EST System Unit : mm


Platform Head Body
D1 Hex Length
|| Diameter Diameter Diameter Code
D0 (H) (L)
(D0) (D1) (D2)
7 EFSR407
9 EFSR409
4.1 4.1 4.0 2.7 11 EFSR411
L
13 EFSR413
Hex
15 EFSR415

D2

Wide EST System Unit : mm


Platform Head Body
D1 Hex Length
|| Diameter Diameter Diameter Code
D0 (H) (L)
(D0) (D1) (D2)
7 EFSW507
9 EFSW509
L
5.1 5.1 5.0 3.4 11 EFSW511
13 EFSW513
Hex
15 EFSW515

D2

Wide6.0 EST System Unit : mm


Platform Head Body
D1 Hex Length
Diameter Diameter Diameter Code
D0 (H) (L)
(D0) (D1) (D2)
7 EFSW607
9 EFSW609
5.1 6.0 5.9 3.4
L 11 EFSW611
13 EFSW613
Hex

D2

14 SHINSAEGI MEDI-TECH
Prosthetic Flow Diagrams For EST System
Cement Retained Restoration : Cemented Abutment, Angled Abutment, UCLA Gold Abutment, UCLA Plastic Abutment,
Temporary Abutment

68p
69p 18p

18p

ALIPS Driver ALIPS Screw Abutment Screw 1.2Hex Torque Driver

19p 19p
17p 18p 19p

(Hex) (Non Hex) Angled Abutment (Hex) (Non Hex) (Hex) (Non Hex) (Hex) (Non Hex)
Cemented Abutment UCLA Gold Abutment UCLA Plastic Abutment UCLA Temporary Abutment

18p

Fixture Lab Analog


(Narrow) (Regular) (Wide)

20p 20p

(Hex) (Non Hex) (Hex) (Non Hex)


Fixture Impression Coping (Pick-up) Fixture Impression Coping (Transfer)

67p 67p

16p
16p
16p

0.9Hex Hand Driver Cover Screw Headless Cover Screw Healing Abutment 1.2Hex Hand Driver

14p

Fixture(EST)

SHINSAEGI MEDI-TECH
15
EST System
01 Cover Screw - Head height : 1.5mm
- Instrumentation required 0.9hex hand driver
- Torque recommendation : 5˜8Ncm
Unit : mm
Fixture Platform Head Height (H) Code
1.5
3.5 (Narrow) ESVN350
4.1 (Regular) 1.5 ESVR410
5.1 (Wide) ESVW510

Headless Cover Screw - Instrumentation required 0.9hex hand driver


- Torque recommendation : 5˜8Ncm Unit : mm
Fixture Platform Code
3.5 (Narrow) ESHN350
4.1 (Regular) ESHR410
5.1 (Wide) ESHW510

Healing Abutment - Select the height according to the gingival height (2, 3, 4, 5.5, 7mm)
- Healing size marked for easy identification
(Emergence profile, Restorative, Height)
- Instrumentation required 1.2hex hand driver
- Torque recommendation : 5˜8Ncm
Unit : mm
Fixture Diam- G/H
Platform eter(D) 2 3 4 5.5 7
3.5
4.0 EHAN402 EHAN403 EHAN404 EHAN405 EHAN407
(Narrow)
G/H
4.1 5.0 EHAR502 EHAR503 EHAR504 EHAR505 EHAR507
(Regular) 6.0 EHAR602 EHAR603 EHAR604 EHAR605 EHAR607

D
6.0 EHAW602 EHAW603 EHAW604 EHAW605 EHAW607
5.1
7.0 EHAW702 EHAW703 EHAW704 EHAW705 EHAW707
(Wide)
8.0 EHAW802 EHAW803 EHAW804 EHAW805 EHAW807
5.0 5.0 THAW502 THAW503 THAW504 THAW505 THAW507
(Wide)
T-Type 5.6 THAW602 THAW603 THAW604 THAW605 THAW607
6.0 6.0 THSW602 THSW603 THSW604 THSW605 THSW607
(Wide)
T-Type 6.8 THSW702 THSW703 THSW704 THSW705 THSW707

16 SHINSAEGI MEDI-TECH
EST System
02 Cemented Abutment - Cemented retained restorations
- Height is 8mm with marked groove 6mm and 7mm for easy cutting
- Collar height : 1, 2 ,3, 4mm
- Packing unit : Included abutment screw
(EACN Series + ESATN35, EACRSeries+ESATR41, EACW Series + ESATW51)
- Torque recommendation : 30Ncm
Unit : mm
Gold Ti
Fixture Diameter Height G/H
Type
Platform (D) (H) 1 2 3 4
7 8(H)
6 Hex 8 EACN418H EACN428H EACN438H EACN448H
3.5
4.0
G/H (Narrow) Non-Hex 8 EACN418N EACN428N EACN438N EACN448N
D Hex 8 EACR518H EACR528H EACR538H EACR548H
5.0
4.1 Non-Hex 8 EACR518N EACR528N EACR538N EACR548N
(Regular) Hex 8 EACR618H EACR628H EACR638H EACR648H
Hex
6.0
Non-Hex 8 EACR618N EACR628N EACR638N EACR648N
Non-Hex Hex 8 EACW618H EACW628H EACW638H EACW648H
6.0
Non-Hex 8 EACW618N EACW628N EACW638N EACW648N
5.1 Hex 8 EACW718H EACW728H EACW738H EACW748H
(Wide) 7.0
Non-Hex 8 EACW718N EACW728N EACW738N EACW748N
Hex 8 EACW818H EACW828H EACW838H EACW848H
8.0
Non-Hex 8 EACW818N EACW828N EACW838N EACW848N

Cemented Abutment T-Type - Cement retained restoration


- Combined T-type cemented abutment
- Height is fixed 7mm
- Packing unit : Included abutment screw
(TACN, TACR, TACW Series +ESATR41 or ESAGR41)
- Torque recommendation : 30Ncm
Unit : mm
Gold Ti
Fixture Diameter Height G/H
Type
Platform (D) (H) 1 2 3 4
7(H)
3.4 Hex 7 TACN417H TACN427H TACN437H TACN447H
3.8
G/H (Narrow) Non-Hex 7 TACN417N TACN427N TACN437N TACN447N
D Hex 7 TACR517H TACR527H TACR537H TACR547H
5.0
4.1 Non-Hex 7 TACR517N TACR527N TACR537N TACR547N
(Regular) Hex 7 TACR617H TACR627H TACR637H TACR647H
Hex
6.0
Non-Hex 7 TACR617N TACR627N TACR637N TACR647N
Non-Hex Hex 7 TACW517H TACW527H TACW537H TACW547H
5.5
5.0 Non-Hex 7 TACW517N TACW527N TACW537N TACW547N
(Wide) Hex 7 TACW617H TACW627H TACW637H TACW647H
6.0
Non-Hex 7 TACW617N TACW627N TACW637N TACW647N
Hex 7 TACS617H TACS627H TACS637H TACS647H
6.0 6.0
Non-Hex 7 TACS617N TACS627N TACS637N TACS647N

Cemented Abutment Screw - Instrumentation required 1.2hex Torque driver


- For use Cemented Abutment, T-Type Cemented Abutment & Temporary
Abutment, UCLA Gold Abutment, UCLA Plastic Abutment
Unit : mm
Fixture Platform Thread (T) Ti/Gold Type Code
Ti Hex ESATN35
3.5 (Narrow) M 1.6
Gold Hex ESAGN35
Gold Ti
Ti Hex ESATR41
4.1 (Regular) M 2.0
Gold Hex ESAGR41
Ti Hex ESATW51
5.1 (Wide) M 2.5
Gold Hex ESAGW51

SHINSAEGI MEDI-TECH
17
EST System
Cemented Abutment Screw (T-Type) Unit : mm
Fixture Platform Thread (T) Ti/Gold Type Code
3.4 Ti Hex ESATR41
4.1 M 2.0
Gold Ti
5.0 Gold Hex ESAGR41

ALIPS Locking Abutment Screw - For use cemented abutment


- ALIPS(Anti Lock Inner Post Screw)
- Instrumentation required ALIPS driver
Unit : mm
Fixture Platform Thread (T) Code
3.5 (Narrow) M 1.6 ESAP001
4.1 (Regular) M 2.0 ESAP002
5.1 (Wide) M 2.5 ESAP003

Fixture Lab Analog(UCLA) Unit : mm


Fixture Platform Type Code
3.5 (Narrow) Hex ELUN350
4.1 (Regular) Hex ELUR410
5.1 (Wide) Hex ELUW510
5.0(Wide) T-Type Hex TLUW500
6.0 (Wide) T-Type Hex TLUS600

03 Angled Abutment - Cement retained restorations


- Angulation : 15 , 25
- Collar height : 2mm, 4mm
- Packing unit : Included abutment screw
(EAAN Series + ESAAN35, EAAR Series + ESAAR41,
EAAW Series + ESAAW51, TAAW Series + ESAAR41)
- Torque recommendation : 30Ncm
Unit : mm
Diameter Angel
7 Fixture Platform G/H
(D) 15 25
G/H
2 EAAN4215 EAAN4225
3.5 (Narrow) 4.0
4 EAAN4415 EAAN4425
2 EAAR5215 EAAR5225
5.0
D 4 EAAR5415 EAAR5425
4.1 (Regular)
2 EAAR6215 EAAR6225
6.0
4 EAAR6415 EAAR6425
2 EAAW6215 EAAW6225
5.1 (Wide) 6.0
4 EAAW6415 EAAW6425
2 TAAW6215 TAAW6225
5.0(Wide) T-Type 6.0
4 TAAW6415 TAAW6425

18 SHINSAEGI MEDI-TECH
EST System
Angled Abutment Screw - Instrumentation required 1.2hex Torque driver
Unit : mm
Fixture Platform Code
3.5 (Narrow) ESAAN35
4.1 (Regular) ESAAR41
5.1 (Wide) ESAAW51

04 UCLA Gold Abutment - Screw retained restoration


- Gold alloy
- Packing unit : Included abutment screw
- Torque recommendation : 30Ncm Unit : mm
Gold Ti
Fixture Platform Diameter (D) Type Code
Hex EAGN00H
3.5 (Narrow) 4.0
Non-Hex EAGN00N
Hex EAGR00H
4.1 (Regular) 4.5
Non-Hex EAGR00N
Hex Non-Hex Hex EAGW00H
5.1 (Wide) 5.5
D Non-Hex EAGW00N
Hex TAGW00H
5.0(Wide) T-Type 5.5
Non-Hex TAGW00N

05 UCLA Plastic Abutment - Screw retained restoration


- Packing unit : Included Abutment Screw
- Torque recommendation : 30Ncm
Unit : mm
Fixture Platform Diameter (D) Type Code
Ti Hex EAPN00H
3.5 (Narrow) 4.0
Non-Hex EAPN00N
Hex EAPR00H
4.1 (Regular) 4.5
Non-Hex EAPR00N
Hex EAPW00H
5.1 (Wide) 5.5
Hex Non-Hex Non-Hex EAPW00N
Hex TAPW00H
D 5.0(Wide) T-Type 5.5
Non-Hex TAPW00N

06 UCLA Temporary Abutment - Temporary restoration


- Packing unit : Included abutment screw
(ETUN Series+ ESATN35, ETURSeries + ESATR41,
ETUWSeries + ESATW51, TTUW Series + ESATR41)
- Torque recommendation : 15Ncm
Unit : mm
Ti
Fixture Platform Diameter (D) Type Code
Hex ETUN40H
3.5 (Narrow) 4.0
Non-Hex ETUN40N
Hex ETUR50H
4.1 (Regular) 4.5
Non-Hex ETUR50N
Hex Non-Hex
Hex ETUW60H
5.1 (Wide) 5.5
D Non-Hex ETUW60N
Hex TTUW60H
5.0(Wide) T-Type 5.5
Non-Hex TTUW60N

SHINSAEGI MEDI-TECH
19
EST System

07 Impression Coping(Pick-up) - Length : 12mm


- Packing unit : Included guide pin
Unit : mm
Fixture Platform Diameter (D) Type Code
Hex EIPN40H
3.5 (Narrow) 4.0
Non-Hex EIPN40N
Hex EIPR50H
5.0
Non-Hex EIPR50N
4.1 (Regular)
Hex EIPR60H
6.0
Non-Hex EIPR60N
Hex EIPW60H
5.1 (Wide) 6.0
Non-Hex EIPW60N
Hex TIPW55H
5.5
Hex Non-Hex Non-Hex TIPW55N
5.0(Wide) T-Type
Hex TIPW60H
D 6.0
Non-Hex TIPW60N

Guide Pin(Pick-up) - Instrument required 1.2hex driver


Unit : mm
Fixture Platform Height (H) Code
Narrow 15 ESGPN150
H
15 ESGPR150
Regular
17 ESGPR170
Wide 15 ESGPW150

Impression Coping(Transfer) - Hex type(Two-piece)


- Non hex type(One-piece, Two-piece)
Unit : mm
Fixture Platform Diameter (D) Type Code
Hex EITN45H
3.5 (Narrow) 4.5
Non-Hex EITN45N
Hex EITR50H
4.1 (Regular) 5.0
Non-Hex EITR50N
Hex EITW60H
5.1 (Wide) 6.0
Non-Hex EITW60N

Hex Non-Hex

Guide Pin(Transfer)
Unit : mm
Fixture Platform Code
3.5 (Narrow) ESGTN35
4.1 (Regular) ESGTR41
5.1 (Wide) ESGTW51

20 SHINSAEGI MEDI-TECH
Prosthetic Flow Diagrams For EST System
Screw Retained restoration : Estheticone, Midicone, Widecone, T-Type Widecone Abutment, Locking Abutment.

68p
25p

68p
22p
69p
1.2Hex Torque Driver Cylinder Screw

23p 23p 1.2Hex Torque Driver ALIA EXternal Locking Repositioning Jig
22p
Abutment Screw

Conical Gold Cylinder Conical Plastic Cylinder Conical Temporary Cylinder


24p

ALIA EXternal Locking Abutment


24p (Hex)

25p
Fixture Lab Analog

23p 24p
ALIA EXternal Locking Lab Analog
(Upper) (Lower)

Conical Impression Coping Conical Impression Coping


(Pick-up) (Transfer)

25p

22p
Impression Plastic Cap
Conical Healing Cap

22p
25p

Conical Abutment Screw


69p

22p

Conical Abutment EXternal YK Transfer Repositioning Jig


(Estheticone, Midicone, Adapter & Screw (EST)
Widecone, Widecone T-Type)

67p 67p

16p
16p
16p

0.9Hex Hand Driver Cover Screw Headless Cover Screw Healing Abutment 1.2Hex Hand Driver

14p

Fixture(EST)

SHINSAEGI MEDI-TECH
21
EST System
08 Conical Abutment - Screw retained restoration
- Collar height : 1, 2, 3, 4mm
- Length : Estheticone 1.8mm, Widecone 1.0mm and Midicone 1.0mm
- Instrumentation required Estheticone & Midicone 2.0hex driver,
Widecone 2.7hex driver
- Packing unit : Included abutment screw
(EAE Series + ESE001, EAM Series + ESM001, EAW Series + ESW001,
TAW501 Series + TSW001, TAW Series + TSW002)
- Torque recommendation : 30Ncm
H Unit : mm
G/H
Fixture Diameter Height G/H
D Platform (D) (H) 1 2 3 4
Estheticone 4.8 1.8 EAE401 EAE402 EAE403 EAE404
Midicone 4.8 1.0 EAM401 EAM402 EAM403 EAM404
Widecone 5.5 1.0 EAW501 EAW502 EAW503 EAW504
Widecone 5.0 1.0 TAW501 TAW502 TAW503 TAW504
T-Type 6.5 1.3 TAW601 TAW602 TAW603 TAW604

Conical Abutment Screw - Instrumentation required 1.2hex Torque driver


Unit : mm
Fixture Platform Hex Code
Estheticone 2.0 ESE001
Midicone 2.0 ESM001
Widecone 2.7 ESW001
Widecone 2.0 TSW001
T-Type 2.0 TSW002

Conical Healing Cap - Instrumentation required 1.2hex driver


- Torque recommendation : 20Ncm
Unit : mm
Fixture Platform Diameter (D) Code
H Estheticone 5.5 ECE001
Midicone 5.5 ECM001
D
Widecone 6.2 ECW001
Widecone 5.0 TCW001
T-Type 6.5 TCW002

Conical Gold Cylinder - Gold alloy


- Packing unit : Included cylinder screw
(Estheticone + ESYTE41(ESYGE41), Midicone + ESYTM41(ESYGM41),
Widecone + ESYTW51(ESYGW51), Widecone(T) +TSYIW50(TSYGW50))
- Torque recommendation : 20Ncm
Gold Ti Unit : mm
Fixture Platform Diameter (D) Type Code
Hex EAGE00H
Estheticone 4.8
Non-Hex EAGE00N
Hex EAGM00H
Hex Non-Hex
Midicone 4.8
Non-Hex EAGM00N
D Hex EAGW00H
Widecone 5.5
Non-Hex EAGW00N
Widecone Hex TAGW00H
T-Type 5.5
Non-Hex TAGW00N

22 SHINSAEGI MEDI-TECH
EST System
Conical Plastic Cylinder - Packing unit : Included cylinder screw
(Estheticone + ESYTE41, Midicone + ESYTM41, Widecone + ESTW51,
Widecone(T) + TSYTW50)
- Torque recommendation : 20Ncm
Unit : mm
Ti
Fixture Platform Diameter (D) Type Code
Hex EAPE00H
Estheticone 4.8
Non-Hex EAPE00N
Hex EAPM00H
Midicone 4.8
Non-Hex EAPM00N
Hex Non-Hex Hex EAPW00H
Widecone 5.5
D
Non-Hex EAPW00N
Widecone Hex TAPW00H
T-Type 5.5
Non-Hex TAPW00N

Conical Temporary Cylinder - Screw retained restoration


- Packing unit : Included cylinder screw
(Estheticone + ESYTE41, Midicone + ESYTM41, Widecone + ESYTW51,
Widecone(T) + TSYTW50)
- Torque recommendation : 20Ncm Unit : mm
Ti
Fixture Platform Diameter (D) Type Code
Hex ETE001H
Estheticone 4.8
Non-Hex ETE001N
Hex ETM001H
Midicone 5.3
Non-Hex ETM001N
Hex Non-Hex Hex ETW001H
Widecone 6.0
D Non-Hex ETW001N
Hex TTW001H
6.0
Widecone Non-Hex TTW001N
T-Type Hex TTW002H
6.5
Non-Hex TTW002N

Conical Cylinder Screw - Instrumentation required 1.2hex Torque driver Unit : mm


Fixture Platform Type Product
Ti ESYTE41
Estheticone
Gold ESYGE41
Ti ESYTM41
Midicone
Gold ESYGM41
Gold Ti
Ti ESYTW51
Widecone
Gold ESYGW51
Widecone Ti TSYTW50
T-Type Gold TSYGW50

Conical Impression Coping(pick-up) - Packing unit : Included guide pin Unit : mm


Fixture Platform Type Product
Estheticone Hex EIPE00H
(Regular) Non-Hex EIPE00N
Midicone Hex EIPM00H
(Regular) Non-Hex EIPM00N
Widecone Hex EIPW00H
(Wide) Non-Hex EIPW00N
Widecone Hex TIPW00H
(Wide) T-Type Non-Hex TIPW00N

Hex Non-Hex

SHINSAEGI MEDI-TECH
23
EST System
Conical Guide Pin(pick-up) - Instrument required 1.2hex driver Unit : mm
Fixture Platform Height (H) Product
8 ESGE080
Estheticone 13 ESGE130
15 ESGE150
8 ESGM080
H
Midicone 13 ESGM130
15 ESGM150
8 ESGW080
Widecone 13 ESGW130
15 ESGW150
8 TSGW080
Widecone
13 TSGW130
T-Type
15 TSGW150

Conical Impression Coping (Transfer) Unit : mm


Fixture Platform Type Product
4.1 (Regular) Estheticone EITE00N
4.1 (Regular) Midicone EITM00N
5.1 (Wide) Widecone EITW00N
5.0 (Wide) T-Type Widecone TITW00N

Conical Lab Analog Unit : mm


Fixture Platform Type Product
4.1 (Regular) Estheticone ELEH410
4.1 (Regular) Midicone ELEL410
5.1 (Wide) Widecone ELEL510
5.0 (Wide) T-Type Widecone TLEL500
6.0 (Wide) T-Type Widecone TLEL600

09 ALIA External Locking Abutment (Hex) - Screw retained restoration


- Hexagon base for anti-rotating locking with a locking abutment screw
- Packing unit : Included abutment screw
(EALN Series + ESLN Series, EALR Series + ESLR Series, EALW Series +
ESLW Series)
ex) EALN401H + ESLN401
- Torque recommendation : 30Ncm
Unit : mm
Fixture Diameter Hex G/H
Platform (D) (H) 1 2 3 4
3.5 (Narrow) 4.0 2.4 EALN401H EALN402H EALN403H EALN404H
5.0 2.7 EALR501H EALR502H EALR503H EALR504H
4.1 (Regular)
G/H 6.0 2.7 EALR601H EALR602H EALR603H EALR604H
6.0 3.4 EALW601H EALW602H EALW603H EALW604H
5.1 (Wide) 7.0 3.4 EALW701H EALW702H EALW703H EALW704H
Hex
8.0 3.4 EALW801H EALW802H EALW803H EALW804H
D 6.0 2.7 TALW601H TALW602H TALW603H TALW604H
5.0 (Wide)
7.0 2.7 TALW701H TALW702H TALW703H TALW704H
6.0 2.7 TALS601H TALS602H TALS603H TALS604H
6.0 (Wide)
7.0 2.7 TALS701H TALS702H TALS703H TALS704H

24 SHINSAEGI MEDI-TECH
EST System
External Locking Abutment Screw - Instrument required 1.2hex Torque driver or Positioning Jig
Unit : mm
Length(L)
Fixture Platform
8 9 10 11
3.5 (Narrow) ESLN401 ESLN402 ESLN403 ESLN404
ESLR501 ESLR502 ESLR503 ESLR504
4.1 (Regular)
ESLR601 ESLR602 ESLR603 ESLR604
L ESLW601 ESLW602 ESLW603 ESLW604
5.1 (Wide) ESLW701 ESLW702 ESLW703 ESLW704
ESLW801 ESLW802 ESLW803 ESLW804
TSLW601 TSLW602 TSLW603 TSLW604
5.0 (Wide)
TSLW701 TSLW702 TSLW703 TSLW704

External YK Transfer Adapter - Packing unit : Included External YK Transfer screw


- Torque recommendation : 15Ncm
Unit : mm
Fixture Platform Diameter (D) Hex G/H Code
1.5 ETLN150
3.5 4.0 2.4
3.5 ETLN350
1.5 ETLR150
4.1 5.0 2.7
3.5 ETLR350
1.5 ETLW150
5.1 6.0 3.4
G/H 3.5 ETLW350
1.5 TTLW150
5.0 6.0 2.7
Hex 3.5 TTLW350

External YK Transfer Screw - Instrument required 1.2hex Torque driver or Positioning Jig
Unit : mm
Fixture Platform Diameter (D) Length (L) Code
9 ESTLN35S
3.5 3.36
11 ESTLN35L
9 ESTLR41S
4.1 3.86
11 ESTLR41L
L
9 ESTLW51S
5.1 4.86
11 ESTLW51L
9 TSTLW50S
5.0 4.86
11 TSTLW50L

Impression Plastic Cap Unit : mm


Code
SIYC 600

External Locking Lab Analog - Packing unit : Included Upper+Lower


Unit : mm
Fixture Platform Type Code
Upper ELLN001
3.5
Lower ELLN002
Upper ELLR001
4.1
Lower ELLR002
Upper ELLW001
5.1
Lower ELLW002
(Upper) (Lower)
5.0 Upper TLLW001
T-Type Lower TLLW002
6.0 Upper TLLS001
T-Type Lower TLLS002

SHINSAEGI MEDI-TECH
25
Prosthetic Flow Diagrams For EST System
Overdenture Retained Restoration for O-Ring Abutment

27p 27p

For Denture O-Ring For laboratory O-Ring


(Red) (Black)

27p

O-Ring Retainer

27p

O-Ring Lab Analog

27p
68p

O-Ring Abutment O-Ring Abutment Driver


(2.4 Hex)

67p 67p

16p
16p
16p

0.9Hex Hand Driver Cover Screw Headless Cover Screw Healing Abutment 1.2Hex Hand Driver

14p

Fixture(EST)

26 SHINSAEGI MEDI-TECH
EST System
10 O-Ring Abutment - Overdenture restoration
- Multiple implant bone retained and fixed removable overdentures
- Seating surface diameter 4.1mm
- Collar height : 2, 3, 4, 5, 6mm
G/H
- Instrument required O-Ring Abutment Driver(2.4hex)
- Packing unit : Included O-Ring 2ea and O-Ring Retainer 1ea
Unit : mm
Fixture Diam- G/H
D
Platform eter(D) 2.0 3.0 4.0 5.0 6.0
4.1
5.0 EARR200 EARR300 EARR400 EARR500 EARR600
(Regular)

O-Ring Unit : mm
Type Code
Red(Denture) IARR002
Black(Laboratory) IARR003

O-Ring Retainer - Female receptacle processed into denture


Unit : mm
Code
IARR001

O-Ring Lab Analog Unit : mm


Code
RL001

SHINSAEGI MEDI-TECH
27
28 SHINSAEGI MEDI-TECH
Submerged
Fixture
Esthetic & Innovation

SHINSAEGI MEDI-TECH
SHINSAEGI MEDI-TECH
29
SST System

01 Sub-Cover Screw 34p


Sub-Healing Abutment 34p
02 Sub-Solid Abutment 34p
Sub-Solid Impression Coping 35p
Sub-Solid plastic Coping 35p
Sub-Solid Healing Cap 35p
Sub-Solid Lab Analog 35p
03 Sub-Cemented Abutment 37p
Sub-Cemented Abutment Screw 37p
ALIPS Locking Abutment Screw 37p
04 Sub-Angled Abutment 37p
05 Sub-Temporary Abutment 37p
Sub-Impression Coping (Pick-up) 38p
Sub-Impression Coping Guide Pin (Pick-up) 38p
Sub-Impression Coping Guide Pin (Transfer) 38p
Sub-Impression Coping (Transfer) 38p
Sub-Gold Abutment 38p
Sub-Fixture Lab Analog 38p
06 ALIA Sub-Locking Abutment (Hex) 40p
Sub-Locking Abutment Screw 40p
Sub-YK Transfer Adapter 40p
Sub-YK Transfer Screw 40p
Sub-Locking Fixture Lab Analog 40p
07 Sub-O-Ring Abutment 42p
Sub-O-Ring 42p
Sub-Retainer 42p
Sub-O-Ring Lab Analog 42p

30 SHINSAEGI MEDI-TECH
EXTERNAL (EST)
Submerged Slightly Tapered Fixture (SST System)
- SST implant components and ASTRA implant components are fully interchangeable.

The inner of head Body of head

SUBMERGED (SST)
Flapless surgery
Internal Hex connection - Head design is the same
diameter as the implant body
- This implant ideal for surgery
No counter sinking
- This makes the surgical
procedure faster and simple.

Micro groove

INTERNAL (IST.IT)
- Acheive both soft and hard
tissue attachement
- Generate strong attachment
of cortical bone
- Superior primary stability

Apex
Body design
INTERNAL (IST.IT)

Sharp tip on 3-cutting edge


-This sharp tip also secures a
smooth insertion without the
implant wobbling Slightly taper
-Implant will not spin and loss -This design for increased initial
stablity when a higher density stablity in soft bone
area in reached Unique grooves
-This thread design make the -Increase stability compared to
implant a very efficient "v"type thread implant
selftapping unit.

SHINSAEGI MEDI-TECH
31
Submerged Slightly Tapered Fixture (SST System)
Feature - Submerged Internal Hex connection
- Hex : 2.5mm
- Apex size : Narrow( 2.25mm), Regular( 2.9mm), Wide( 3.6mm), Wide6.0( 4.3mm)
- Torque recommendation : 40Ncm

Narrow SST System Unit : mm


Platform Head Body
D1 Hex Length
|| Diameter Diameter Diameter Code
D0 (H) (L)
(D0) (D1) (D2)
9 SFSN309
11 SFSN311
L 3.8 3.8 3.75 2.5
13 SFSN313
Hex 15 SFSN315

D2

Regular SST System Unit : mm


Platform Head Body
D1 Hex Length
|| Diameter Diameter Diameter Code
D0 (H) (L)
(D0) (D1) (D2)
7 SFSR407
9 SFSR409
L
4.3 4.3 4.2 2.5 11 SFSR411
Hex 13 SFSR413
15 SFSR415
D2

Wide SST System Unit : mm


Platform Head Body
D1 Hex Length
|| Diameter Diameter Diameter Code
D0 (H) (L)
(D0) (D1) (D2)
7 SFSW507
9 SFSW509
L
5.0 5.0 4.9 2.5 11 SFSW511
Hex 13 SFSW513
15 SFSW515
D2

Wide6.0 SST System Unit : mm


Platform Head Body
D1 Hex Length
Diameter Diameter Diameter Code
D0 (H) (L)
(D0) (D1) (D2)
7 SFSW607
9 SFSW609
L 5.0 6.0 5.9 2.5
11 SFSW611
13 SFSW613
Hex

D2

32 SHINSAEGI MEDI-TECH
Prosthetic Flow Diagrams For SST System
Cement Retained restoration for Sub-Solid Abutment

35p

(Single) (Bridge)
Sub-Solid Plastic Coping

35p

Sub-Solid Lab Analog

34p

Sub-Solid Impression Coping

35p

Sub-Solid Healing Cap

68p
34p

1.2Hex Torque Driver Sub-Solid Abutment


( 4.5, 5.5, 6.5) 67p

34p
34p

Sub-Cover Screw Sub-Healing Abutment 1.2Hex Hand Driver

32p

Fixture(SST)

SHINSAEGI MEDI-TECH
33
SST System
01 Sub-Cover Screw - Head height : 0.5, 1.5mm
- Instrumentation required 1.2hex hand driver
- Torque recommendation : 5˜8Ncm
Unit : mm
Platform Diameter(D) Height (H) Code
3.8
0.5 SSV001
4.3
5.0
1.5 SSV002
6.0

Sub-Healing Abutment - Instrumentation required 1.2hex driver


- Torque recommendation : 5˜8Ncm Unit : mm
Fixture Diam- Code
Platform eter(D) 1.5 2.0 2.5 3.0 3.5 4.5 5.0 5.5
2
G/H
3.8
4.5 SHAN4515 - SHAN4525 - SHAN4535 SHAN4545 - SHAN4555
(Narrow)
D
4.3 5.0 - SHAR5020 - SHAR5030 - - SHAR5050 -
(Regular) 5.5 SHAR5515 - SHAR5525 - SHAR5535 SHAR5545 - SHAR5555
5.0 6.5 SHAW6515 - SHAW6525 - SHAW6535 SHAW6545 - SHAW6555
6.0
(Wide) 7.5 SHAW7515 - SHAW7525 - SHAW7535 SHAW7545 - SHAW7555

02 Sub-Solid Abutment - Cement retained restoration


- Height is 5.5mm with marked groove 4mm for easy cutting
- Collar height : 1.5, 2.5, 3.5, 4.5, 5.5mm and specially SASN series height
1.0, 1.5, 2.5, 3.5, 4.5mm
- Profile diameter : 4.5, 5.5, 6.5mm
- Instrument required 1.2hex driver
4 5.5 - Torque recommendation : 30Ncm
Unit : mm
G/H
Fixture Diam- Code
Platform eter(D) 1.0 1.5 2.5 3.5 4.5 5.5
D 3.8
4.5 SASN4510 SASN4515 SASN4525 SASN4535 SASN4545 -
(Narrow)

4.3
5.5 - SASR5515 SASR5525 SASR5535 SASR5545 SASR5555
(Regular)
5.0
6.0 6.5 - SASW6515 SASW6525 SASW6535 SASW6545 SASW6555
(Wide)

34 SHINSAEGI MEDI-TECH
SST System
Sub-Solid Impression Coping Unit : mm
Diameter (D) Code
4.5 SISC45L
5.5 SISC55L
6.5 SISC65L

Sub-Solid plastic Coping Unit : mm


Diameter (D) Type Code
Single SISP45S
4.5
Bridge SISP45B
Single SISP55S
5.5
Bridge SISP55B
Single SISP65S
Single Bridge 6.5
Bridge SISP65B

Sub-Solid Healing Cap Unit : mm


Diameter (D) Code
4.5 SHS45L
5.5 SHS55L
6.5 SHS65L
D

Sub-Solid Lab Analog Unit : mm


Diameter (D) Height (H) Code
4.0 SLSN45S
H
4.5
5.5 SLSN45L
4.0 SLSR55S
5.5
5.5 SLSR55L
4.0 SLSW65S
Short Long 6.5
5.5 SLSW65L

SHINSAEGI MEDI-TECH
35
Prosthetic Flow Diagrams For SST System
Screw & Cement Retained restoration for Sub-Cement Abutment, Sub-Angled Abutment, Sub-Temporary
Abutment, Sub-Gold Abutment

68p
69p 37p

37p

ALIPS Driver ALIPS Locking Screw Sub-Abutment Screw 1.2Hex Torque Driver

37p 38p
37p 37p

(Hex) (Non Hex) (Hex) (Non Hex) (Hex) (Non Hex) (Hex) (Non Hex)
Sub-Cemented Abutment Sub-Angled Abutment Sub-Temporary Abutment Sub-Gold Abutment

38p

Sub-Fixture Lab Analog

38p 38p

(Hex) (Non Hex) (Hex) (Non Hex)


Sub-Impression Coping (Pick-up) Sub-Impression Coping (Transfer)

67p

34p
34p

Sub-Cover Screw Sub-Healing Abutment 1.2Hex Hand Driver

32p

Fixture(SST)

36 SHINSAEGI MEDI-TECH
SST System

03 Sub-Cemented Abutment - Cement retained restoration - Collar height : 1.5, 2.5, 3.5, 4.5, 5.5mm
- Specially SACN series height : 1.0, 2.5, 3.5, 4.5mm
- Packing unit : Included abutment screw(SSA001)
- Profile diameter : 4.5, 5.5, 6.5mm
- Length is 7mm with marked microgroove 4.0mm and 5.5mm for easy cutting
- Torque recommendation : 30Ncm
Unit : mm
Fixture Diam- Length G/H
Type
4 5.5 7 L Platform eter(D) (L) 1.0 1.5 2.5 3.5 4.5 5.5
G/H Hex SAC4510H SAC4515H SAC4525H SAC4535H SAC4545H -
5.5
D 3.8 Non-Hex SAC4510N SAC4515N SAC4525N SAC4535N SAC4545N -
4.5
(Narrow) Hex SACN4510H SACN4515H SACN4525H SACN4535H SACN4545H -
7.0
Hex Non-Hex Non-Hex SACN4510N SACN4515N SACN4525N SACN4535N SACN4545N -
Hex - SAC5515H SAC5525H SAC5535H SAC5545H SAC5555H
5.5
4.3 Non-Hex - SAC5515N SAC5525N SAC5535N SAC5545N SAC5555N
5.5
(Regular) Hex - SACR5515H SACR5525H SACR5535H SACR5545H SACR5555H
7.0
Non-Hex - SACR5515N SACR5525N SACR5535N SACR5545N SACR5555N
5.0 Hex - SAC6515H SAC6525H SAC6535H SAC6545H SAC6555H
5.5
(Wide) Non-Hex - SAC6515N SAC6525N SAC6535N SAC6545N SAC6555N
6.5
6.0 Hex - SACW6515H SACW6525H SACW6535H SACW6545H SACW6555H
7.0
(Wide) Non-Hex - SACW6515N SACW6525N SACW6535N SACW6545N SACW6555N

Sub-Cemented Abutment Screw - Instrumentation required 1.2hex Torque driver Unit : mm


Code
SSA001

ALIPS Locking Abutment Screw - For use In-octa cemented abutment - ALIPS(Anti Lock Inner Post Screw)
- Instrumentation required ALIPS driver Unit : mm
Diameter (D) Code
3.8
4.3
ISAP001
5.0
6.0

04 Sub-Angled Abutment - Cement retained restorations


- Collar height : 2mm, 4mm
- Angulation : 15 , 25

- Packing unit : Included abutment screw (SSA001) Unit : mm


Fixture Diameter Angle G/H
Platform (D) ( ) 2.0 4.0
7
15 SAAN4152H (N) SAAN4154H (N)
G/H 3.8 (Narrow) 4.5
25 SAAN4252H (N) SAAN4254H (N)
D 15 SAAR5152H (N) SAAR5154H (N)
4.3 (Regular) 5.5
25 SAAR5252H (N) SAAR5254H (N)
Hex Non-Hex

05 Sub-Temporary Abutment - Packing unit : Included Abutment Screw(SSA001)


- Torque recommendation : 30Ncm Unit : mm
G/H Type 4.5
G/H Hex STAN4510H
1.0
Non-Hex STAN4510N
Hex Non-Hex Hex STAN4530H
3.0
D Non-Hex STAN4530N

SHINSAEGI MEDI-TECH
37
SST System
Sub-Impression Coping (Pick-up) - Packing unit : Included Guide Pin
Unit : mm
Fixture Platform Diameter (D) Length (L) Code
Short14 SIPN45HS
Hex
Long18 SIPN45HL
4.5
Short14 SIPN45NS
Non-Hex
Long18 SIPN45NL
Short14 SIPR55HS
Hex
H Long18 SIPR55HL
5.5
Short14 SIPR55NS
Non-Hex
Long18 SIPR55NL
Hex Non-Hex
Short14 SIPW65HS
D Hex
Long18 SIPW65HL
6.5
Short14 SIPW65NS
Non-Hex
Long18 SIPW65NL

Sub-Impression Coping Guide Pin (Pick-up) Unit : mm


Height (H) Code
Short SSGP00S
Long SSGP00L

Sub-Impression Coping (Transfer) Unit : mm


Fixture Platform Diameter (D) Length (L) Code
Short10 SITN45HS
Hex
Long14 SITN45HL
4.5
Short10 SITN45NS
Non-Hex
Long14 SITN45NL
Short10 SITR55HS
Hex
Long14 SITR55HL
L 5.5
Short10 SITR55NS
Non-Hex
Long14 SITR55NL
Hex Non-Hex Short10 SITW65HS
Hex
D Long14 SITW65HL
6.5
Short10 SITW65NS
Non-Hex
Long14 SITW65NL

Sub-Impression Coping Guide Pin (Transfer) Unit : mm


Height (H) Code
Short SSGT00S
Long SSGT00L

Sub-Gold Abutment - Packing unit : Included Abutment Screw(SSA001)


- Torque recommendation : 30Ncm
Unit : mm
G/H Type 4.5 5.5 6.5
G/H Hex SAGN4510H SAGN5510H SAGN6510H
1.0
Non-Hex SAGN4510N SAGN5510N SAGN6510N
Hex Non-Hex Hex SAGN4530H SAGN5530H SAGN6530H
3.0
D Non-Hex SAGN4530N SAGN5530N SAGN6530N

Sub-Fixture Lab Analog Unit : mm


Code
SLFR001

38 SHINSAEGI MEDI-TECH
Prosthetic Flow Diagrams For SST System
Cement & Screw Retained Restoration Component for Sub-Locking Abutment, Sub-Locking Temporary Abutment

68p
40p
69p

1.2Hex Torque Driver ALIA Sub-Locking Abutment Screw Repositioning Jig

40p

ALIA Sub-Locking Abutment

40p

ALIA Sub-Locking Lab Analog


(Upper) (Lower)

40p

Impression Plastic Cap

69p
40p

Sub-YK Transfer Adapter & Screw Repositioning Jig


(SST) 67p

34p
34p

Sub-Cover Screw Sub-Healing Abutment 1.2Hex Hand Driver

32p

Fixture(SST)

SHINSAEGI MEDI-TECH
39
SST System
06 ALIA Sub-Locking Abutment (Hex) - Screw retained restoration
- Hexagon base for anti-rotating locking with a locking abutment screw
- Packing unit : Included abutment screw
(SALN Series + SSLN Series, SALR Series + SSLR Series, SALW Series
+ SSLW Series)
- Torque required 30Ncm
Unit : mm
Fixture Diameter G/H
Platform (D) 1 1.5 2.5 3.5 4.5
G/H
3.8 (Narrow) 4.5 SALN4510H SALN4515H SALN4525H SALN4535H SALN4545H
4.3 (Regular) 5.5 - SALR5515H SALR5525H SALR5535H SALR5545H
D
5.0 (Wide)
6.5 - SALW6515H SALW6525H SALW6535H SALW6545H
6.0 (Wide)

Sub-Locking Abutment Screw - Instrumentation required 1.2Hex Torque driver or reposintiong Jig
Unit : mm
Fixture Length(L)
Platform 8 9 10 11 12
3.8 (Narrow) SSLN4510 SSLN4515 SSLN4525 SSLN4535 SSLN4545
L
4.3 (Regular) - SSLR5515 SSLR5525 SSLR5535 SSLR5545
5.0 (Wide)
- SSLW6515 SSLW6525 SSLW6535 SSLW6545
6.0 (Wide)

Impression Plastic Cap Unit : mm


Code
SIYC 600

Sub-YK Transfer Adapter Unit : mm


G/H Code
G/H 1.5 STAL150
3.5 STAL350

Sub-YK Transfer Adapter Screw - Instrumentation required 1.2Hex driver or reposintiong Jig
Unit : mm
Height(H) Code
9 SSTL090
H 11 SSTL110

Sub-Locking Fixture Lab Analog Unit : mm


Type Code
Upper SLLR001
Lower SLLR002

(Upper) (Lower)

40 SHINSAEGI MEDI-TECH
Prosthetic Flow Diagrams For SST System
Overdenture Retained Restoration for O-Ring Abutment

42p 42p
For Denture O-Ring For Laboratory O-Ring

42p

Retainer

42p

Sub-O-Ring Lab Analog

68p 42p

O-Ring Abutment Driver Sub-O-Ring Abutment


(2.4Hex)

67p

34p
34p

Sub-Cover Screw Sub-Healing Abutment 1.2Hex Hand Driver

32p

Fixture(SST)

SHINSAEGI MEDI-TECH
41
SST System
07 Sub-O-Ring Abutment - Overdenture restoration
- Multiple implant bone retained and fixed removable overdenture
- Collar height : 1, 2, 3, 4mm
- Instrument required : O-Ring abutment driver(2.4Hex)
- Packing unit : Included O-Ring 2ea, Sub-retainer 1ea
G/H
- Torque recommendation : 30Ncm
Unit : mm
Diameter G/H
D (D) 1.0 2.0 3.0 4.0
4.5 SARN4510 SARN4520 SARN4530 SARN4540
5.5 SARR5510 SARR5520 SARR5530 SARR5540

Sub-O-Ring Unit : mm
Type Code
Red(Denture) IARR002
Black(Laboratory) IARR003

Sub-Retainer - Female receptacle processed into denture


Unit : mm
Code
IARR001

Sub-O-Ring Lab Analog Unit : mm


Code
RL001

42 SHINSAEGI MEDI-TECH
Internal
Fixture
Esthetic & Innovation

SHINSAEGI MEDI-TECH
SHINSAEGI MEDI-TECH
43
44 SHINSAEGI MEDI-TECH
EXTERNAL (EST)
Internal Slightly Tapered Fixture (IST System)
- IST Implant components and ITI, SWISS PLUS IMPLANT components are fully interchaneable.

The inner of head Body of head Esthetic collar

SUBMERGED (SST)
Machined finished collar of
Internal octa connection 1.8mm

Micro groove under of head

INTERNAL (IST.IT)
Positive anchor as
osseointegration occus
Acheive both soft and hard
tissue attachment
Superior primary stability

Apex

Body design
INTERNAL (IST.IT)

Sharp tip on 3-cutting edge


-This sharp tip also secures a
smooth insertion without the
implant wobbling Slightly taper
-Implant will not spin and loss -This design for increased initial
stablity when a higher density stablity in soft bone
area in reached
-This thread design make the Unique grooves
implant a very efficient -Increase stability compared to
selftapping unit. "v"type thread implant

SHINSAEGI MEDI-TECH
45
Internal Slightly Tapered Fixture (IST System)
Feature - Internal octa connection
- Collar height is fixed 1.8mm
- Apex size : Regular( 2.4mm), Wide( 2.6mm), Wide6.0( 4.0mm)
- Torque recommendation : 40Ncm

Regular IST System


Unit : mm
D1
||
D0 Platform Head Body
Octa Length
Diameter Diameter Diameter Code
(O) (L)
1.8 O (D0) (D1) (D2)
7 IFSR407

L
9 IFSR409
4.8 4.8 4.1 3.1 11 IFSR411
13 IFSR413
D2 15 IFSR415

Wide IST System


Unit : mm
D1
||
D0 Platform Head Body
Octa Length
Diameter Diameter Diameter Code
(O) (L)
1.8 O (D0) (D1) (D2)
7 IFSW507
9 IFSW509
L
4.8 4.8 4.8 3.1 11 IFSW511
13 IFSW513

D2
15 IFSW515

Wide6.0 IST System


Unit : mm
D1
||
D0 Platform Head Body
Octa Length
Diameter Diameter Diameter Code
(O) (L)
1.8 O (D0) (D1) (D2)
7 IFSW607
L 9 IFSW609
6.0 6.0 5.3 3.1
11 IFSW611
13 IFSW613

46 SHINSAEGI MEDI-TECH
Internal
Fixture
Esthetic & Innovation

SHINSAEGI MEDI-TECH
SHINSAEGI MEDI-TECH
47
IT & IST System

01 Cover Screw 52p


Headless Cover Screw 52p
Healing Abutment 52p
02 Solid Abutment 52p
Solid Healing Cap 52p
Solid Impression Coping 53p
Solid Positioning Cylinder 53p
Solid Impression Cap 53p
Solid Impression Shoulder Analog 53p
Solid Impression Shoulder Analog Pin 53p
Solid Plastic Coping 53p
Solid Lab Analog 54p
03 Excellent Solid Abutment 54p
Excellent Solid Healing Cap 54p
Excellent Solid Impression Coping 54p
Excellent Solid Positioning Cylinder 54p
Excellent Solid Impression Cap 55p
Excellent Solid Impression Shoulder Analog 55p
Excellent Solid Impression Shoulder Analog Pin 55p
Excellent Solid Plastic Coping 55p
Excellent Solid Lab Analog 55p
04 Solid Angled Abutment 57p
Solid Angled Abutment Screw 57p
05 In-Octa Cemented Abutment 57p
In-Octa Cemented Abutment Screw 57p
ALIPS Locking Abutment Screw 57p
In-Octa Locking Abutment (Octa) 58p
In-Octa Locking Abutment Screw 58p
In-Octa YK Transfer Adapter 58p
In-Octa YK Transfer Adapter Screw 58p
In-Octa Locking Lab Analog 58p
In-Octa Gold Abutment 59p
In-Octa Impression Coping (pick-up) 59p
In-Octa Guide Pin(pick-up) 59p
In-Octa Impression Coping (Transfer) 59p
In-Octa Guide Pin(Transfer) 59p
In-Octa Lab Analog 59p
06 Octa Abutment 61p
Octa Abutment Healing Cap 61p
Octa Gold Cylinder 61p
Octa Plastic Cylinder 61p
Octa Abutment and Cylinder Screw 62p
Octa Impression Coping (pick-up) 62p
Guide Pin (pick-up) 62p
Octa Lab Analog 62p
07 O-Ring Abutment 64p
O-Ring 64p
O-Ring Retainer 64p
O-Ring Lab Analog 64p

48 SHINSAEGI MEDI-TECH
EXTERNAL (EST)
Internal Tapered Fixture (IT System)
- IT implant components and ITI, SWISS PLUS implant components are fully interchangeable.

The inner of head Body of head Esthetic collar

SUBMERGED (SST)
Machined finished collar of
Internal octa connection 1.8mm

Micro groove under of head

INTERNAL (IST.IT)
Positive anchor as
osseointegration occus
Acheive both soft and hard
tissue attachment
Superior primary stability
Body design

Apex

This design have a tapered


shape similar to roots form
requining less bone removal
and less bone augmentation to
till the extraction socket
INTERNAL (IST.IT)

- This innovation design is a


selftapping tapered implant
that provides lateral
compression of the osteotomy
site to greatly
improve primary stability
- This tapered design make the
implant a very efficient
selftapping unit

SHINSAEGI MEDI-TECH
49
Internal Tapered Fixture (IT System)
Feature - Internal octa connection
- Collar height is fixed 1.8mm
- Apex size : Regular( 2.4mm), Wide( 3.1mm), Wide6.0( 3.6mm)
- Torque recommendation : 40Ncm

Regular IT System
Unit : mm
D1
||
D0 Platform Head Body
Octa Length
Diameter Diameter Diameter Code
(O) (L)
1.8 O (D0) (D1) (D2)
7 IFTR407

L 9 IFTR409
4.8 4.8 4.1 3.1 11 IFTR411
13 IFTR413
D2 15 IFTR415

Wide IT System
Unit : mm
D1
||
D0 Platform Head Body
Octa Length
Diameter Diameter Diameter Code
(O) (L)
1.8 O (D0) (D1) (D2)
7 IFTW507

L 9 IFTW509
4.8 4.8 4.8 3.1 11 IFTW511
13 IFTW513

D2 15 IFTW515

Wide6.0 IT System
Unit : mm
D1
||
D0 Platform Head Body
Octa Length
Diameter Diameter Diameter Code
(O) (L)
1.8 O (D0) (D1) (D2)
7 IFTW607
9 IFTW609
L 6.0 6.0 5.3 3.1
11 IFTW611
13 IFTW613

D2

50 SHINSAEGI MEDI-TECH
Prosthetic Flow Diagrams For IST And IT System
Cement Retained restoration for Solid Abutment, Excellent Solid Abutment

53p, 55p

Single(Red) Bridge(White)
Solid Plastic Coping
Excellent Solid Plastic Coping

54p 55p

Solid Lab Analog


Excellent Solid Lab Analog

53p,55p 53p,55p 53p,55p

Solid Positioning Cylinder Solid shoulder Analog Solid shoulder Analog Pin
Excellent Solid Positioning Cylinder Excellent Solid shoulder Analog Excellent Solid shoulder Analog Pin

53p,55p

Solid Impression Cap


Excellent Solid Impression Cap

52p,54p
68p
52p,54p

Solid Healing Cap Solid Abutment Solid Driver


Excellent Solid Healing Cap Excellent Solid Abutment Excellent Solid Driver
67p

52p 52p 52p

Cover Screw Headless Cover Screw Healing Abutment 1.2Hex Hand Driver

46p 50p

Internal Slightly Fixture(IST) Internal Tapered Fixture(IT)

SHINSAEGI MEDI-TECH
51
IST & IT System
01 Cover Screw - Head height : 1.3mm
- Instrumentation required 1.2Hex hand driver
- Torque recommendation : 5˜8Ncm
Unit : mm
Platform Diameter (mm) Code
4.8 ISV400
6.0 ISV600

Headless Cover Screw - Instrumentation required 1.2Hex hand driver


- Torque recommendation : 5˜8Ncm
Unit : mm
Platform Diameter (mm) Code
4.8
ISH400
6.0

Healing Abutment - Profile diameter : 4.8, 5.5, 6.0, 7.0mm


- Head height : 2, 3, 4mm
- Instrumentation required 1.2hex hand driver
- Torque recommendation : 5˜8Ncm Unit : mm
G/H
Platform Diameter G/H
Diameter(mm) (D) 2 3 4
D
4.8 IHA420 IHA430 IHA440
4.8
5.5 IHA520 IHA530 IHA540
6.0 IHA620 IHA630 IHA640
6.0
7.0 IHA720 IHA730 IHA740

02 Solid Abutment - It is available in three heights to accommodate vertical requirements


(4.0, 5.5, 7.0mm)
- For use in single tooth or multiple unit restoration
- Packing unit : Included solid healing cap
L - Instrumentation required Solid driver
- Torque recommendation : 30Ncm
Unit : mm
Length (L)
Platform Diameter(mm)
4.0 5.5 7.0
4.8 IAS440 IAS455 IAS470

Solid Healing Cap - For use protect for solid abutment


Unit : mm
Height (H) Product
4 IHSC440
5.5 IHSC455
D
7 IHSC470

52 SHINSAEGI MEDI-TECH
IST & IT System
Solid Impression Coping - Solid positioning cylinder + Solid impression cap = Solid impression coping
Unit : mm
Height (H) Code
4 IISI 440
5.5 IISI 455
7 IISI 470

Solid Positioning Cylinder Unit : mm


Platform Diameter(mm) Height (H) Code
4 IISY440
4.8 5.5 IISY455
7 IISY470
4 IISY640
6.0 5.5 IISY655
7 IISY670

Solid Impression Cap Unit : mm


Platform Code
4.8 IISC480
6.0 IISC600
D

Solid Impression Shoulder Analog Unit : mm


Platform Code
4.8 IISL480
6.0 IISL600

Solid Impression Shoulder Analog Pin Unit : mm


Platform Code
4.8 IISN480
6.0 IISN600

Solid Plastic Coping Unit : mm


Platform Diameter(mm) Color Code
Single(Red) IISP48S
4.8
Bridge(White) IISP48B
Single(Red) IISP60S
6.0
Bridge(White) IISP60B

SHINSAEGI MEDI-TECH
53
IST & IT System
Solid Lab Analog Unit : mm
Height (H)
H Platform Diameter(D)
4.0 5.5 7.0
4.8 ILS440 ILS455 ILS470
6.0 ILS640 ILS655 ILS670
D

03 Excellent Solid Abutment - It is available in three height to accommodate vertical requirements


(4.0, 5.5, 7.0mm)
- Instrumentation required 4.8 : Excellent solid driver and 6.0 :
1.2Hex driver
- Packing unit : Included excellent solid healing cap
L
- Torque recommendation : 30Ncm
Unit : mm
Length (L)
Platform Diameter
4.0 5.5 7.0
4.8 IAX440 IAX455 IAX470
6.0 IAX640 IAX655 IAX670

Excellent Solid Healing Cap - For use protect for excellent solid abutment
Unit : mm
Height (H)
Platform Diameter
4.0 5.5 7.0
H 4.8 IHXC440 IHXC455 IHXC470
6.0 IHXC640 IHXC655 IHXC670

Excellent Solid Impression Coping - Excellent Solid positioning cylinder + Solid impression cap = Solid impression coping
Unit : mm
Height (H)
Platform Diameter
4.0 5.5 7.0
H
4.8 IIXI 440 IIXI 455 IIXI 470
6.0 IIXI 640 IIXI 655 IIXI 670

Excellent Solid Positioning Cylinder Unit : mm


Height (H)
Platform Diameter
4.0 5.5 7.0
H
4.8 IIXY440 IIXY455 IIXY470
6.0 IIXY640 IIXY655 IIXY670

54 SHINSAEGI MEDI-TECH
IST & IT System
Excellent Solid Impression Cap Unit : mm
Platform Diameter(D) Code
4.8 IIXC480
6.0 IIXC600
D

Excellent Solid Impression Shoulder Analog Unit : mm


Platform Diameter(D) Code
4.8 IIXL480
6.0 IIXL600

Excellent Solid Impression Shoulder Analog Pin Unit : mm


Platform Diameter(D) Code
4.8 IIXN480
6.0 IIXN600

Excellent Solid Plastic Coping Unit : mm


Platform Diameter Color Code
Single(Red) IIXP48S
4.8
Bridge(White) IIXP48B
Single Bridge Single(Red) IIXP60S
6.0
Bridge(White) IIXP60B

Excellent Solid Lab Analog Unit : mm


Height (H)
H Platform Diameter(D)
4.0 5.5 7.0
4.8 ILX440 ILX455 ILX470
6.0 ILX640 ILX655 ILX670
D

SHINSAEGI MEDI-TECH
55
Prosthetic Flow Diagrams For IST And IT System
Cement and Screw Retained restoration for In-Octa Cemented Abutment, In-Octa Gold Abutment,
Solid Angled Abutment, In-Octa Locking Abutment.

68p
69p 57p 58p

57p

ALIPS Driver ALIPS In-Octa ALIA In-Octa Locking 1.2Hex Torque Driver
Locking Cemented Abutment Screw
Screw Abutment
Screw

58p

59p ALIA In-Octa Locking Abutment

57p 57p

58p
In-Octa Cement Abutment In-Octa Gold Abutment Solid Angled Abutment
(Octa, Non-Octa) (Octa, Non-Octa) (Octa)

ALIA In-Octa Locking Lab Analog


(Upper) (Lower)

59p

58p

In-Octa Lab Analog


Impression Plastic Cap

57p 58p
69p

In-Octa Impression Coping In-Octa YK Transfer Repositioning Jig


(Pick-up) Adapter & Screw (IST&IT)

67p

52p 52p 52p

Cover Screw Headless Cover Screw Healing Abutment 1.2Hex Hand Driver

46p 50p

Internal Slightly Fixture(IST) Internal Tapered Fixture(IT)

56 SHINSAEGI MEDI-TECH
IST & IT System
04 Solid Angled Abutment - Cement retained restoration
- Angulation : 15 , 25
- Packing unit : Included abutment screw(ISAT001)
- Torque recommendation : 30Ncm Unit : mm
7

Angle( ) Code
15 IAA150
25 IAA250

Solid Angled Abutment Screw -Instrumentation required 1.2hex driver


Unit : mm
Code
ISAT001

05 In-Octa Cemented Abutment - Cement retained restorations - Collar height : 0, 1, 2, 3, 4mm


- For use in single tooth or multiple unit restoration
- Packing unit : Included abutment screw (ISCT001)
- Torque recommendation : 30Ncm Unit : mm

5.5 7 Fixture G/H


4 Type
Platform (D) 0 1.0 2.0 3.0 4.0
Octa IAC407O IAC417O IAC427O IAC437O IAC447O
4.8
Octa Non-Octa Non-Octa IAC407N IAC417N IAC427N IAC437N IAC447N
Octa IAC607O IAC617O IAC627O IAC637O IAC647O
D 6.0
Non-Octa IAC607N IAC617N IAC627N IAC637N IAC647N

In-Octa Cemented Abutment Screw - Instrumentation required 1.2hex driver


Unit : mm
Code
ISCT001

ALIPS Locking Abutment Screw - For use In-octa cemented abutment


- ALIPS(Anti Lock Inner Post Screw)
- Instrumentation required ALIPS driver
Unit : mm
Platform Code
4.8
ISAP001
6.0

SHINSAEGI MEDI-TECH
57
IST & IT System
In-Octa Locking Abutment (Octa) - Screw retained restoration
- Octagone base for antirotation locking with a locking abutment screw
- Packing unit : IALR Series + SSLR Series, IALW Series + SSLW Series
- Torque required : 30Ncm
Unit : mm
Fixture Diameter G/H
Platform (D) 1.5 2.5 3.5
G/H
4.8 (Regular) 5.0 IALR515O IALR525O IALR535O
6.0 (Wide) 6.0 IALW615O IALW625O IALW635O

In-Octa Locking Abutment Screw - Instrumentation required 1.2Hex Driver


Unit : mm
Fixture Length (L)
Platform 9 10 11 12
4.8 (Regular) SSLR5515H SSLR5525H SSLR5535H SSLR5545H
L
6.0 (Wide) SSLW6515H SSLW6525H SSLW6535H SSLW6545H

Impression Plastic Cap Unit : mm


Code
SIYC 600

In-Octa YK Transfer Adapter Unit : mm


Fixture Platform G/H Code
1.5 ITLR150
4.8
3.5 ITLR350
1.5 ITLW150
6.0
D 3.5 ITLW350

In-Octa YK Transfer Adapter Screw Unit : mm


Length (L) Code
9 ISTL090
L 11 ISTL110

In-Octa Locking Lab Analog - Packing unit : Included Upper+Lower


Unit : mm
Fixture Platform Type Code
Upper ILTL481
4.8
Lower ILTL482
Upper ILTL601
6.0
(Upper) (Lower)
Lower ILTL602

58 SHINSAEGI MEDI-TECH
IST & IT System
In-Octa Gold Abutment - Gold Alloy
- Packing unit : Included abutment screw ISCT001
- Torque recommendation : 30Ncm
Unit : mm
Platform Diameter (D) Type Code
Octa IAGI48O
4.8
Non-Octa IAGI48N
Octa IAGI60O
6.0
Non-Octa IAGI60N
Octa Non-Octa

In-Octa Impression Coping (pick-up) - Packing unit : Included Guide pin


Unit : mm
Platform Diameter Type Code
Octa IIPI48O
4.8
Non-Octa IIPI48N
Octa IIPI60O
6.0
Non-Octa IIPI60N

Octa Non-Octa

In-Octa Guide Pin(pick-up) - Instrumentation required 1.2Hex Driver


Unit : mm
Height (H) Code
19 ISGI19O

In-Octa Impression Coping (Transfer) Unit : mm


Platform Diameter Type Code
Octa IITI48O
4.8
Non-Octa IITI48N
Octa IITI60O
6.0
Non-Octa IITI60N

In-Octa Guide Pin(Transfer) - Instrumentation required 1.2Hex Driver


Unit : mm
Code
ISGT100

In-Octa Lab Analog Unit : mm


Platform Diameter Code
4.8 ILC400
6.0 ILC600

SHINSAEGI MEDI-TECH
59
Prosthetic Flow Diagram For IST And IT System
Screw Retained Restoration Component for Octa Abutment

62p

(Gold) (Ti)
Cylinder Screw

61p 61p

(Octa) (Non- Octa) (Octa) (Non- Octa)


Octa Gold Cylinder Octa Plastic Cylinder

62p

Octa Lab Analog

62p

(Octa) (Non-Octa)
Octa Impression Coping(Pick-up)
68p

61p

Octa Healing Cap 1.2Hex Torque Driver

68p
61p

Octa Driver Octa Abutment


67p

52p 52p 52p

Cover Screw Headless Cover Screw Healing Abutment 1.2Hex Hand Driver

46p 50p

Internal Slightly Fixture(IST) Internal Tapered Fixture(IT)

60 SHINSAEGI MEDI-TECH
IST & IT System
06 Octa Abutment - Screw retained restoration
- Instrumentation required octa driver
- Torque recommendation : 30Ncm Unit : mm
Platform Diameter Code
4.8
IAO100
6.0

Octa Abutment Healing Cap - For use protect for octa abutment
- Included Ti screw(ISOC400)
- Instrumentation required 1.2Hex Torque driver
- Torque recommendation : 20Ncm Unit : mm
Platform Diameter Code
4.8 ICO400
6.0 ICO600

Octa Gold Cylinder - Gold alloy


- Packing unit : Included abutment screw(ISOC400)
- Torque recommendation : 20Ncm Unit : mm
Platform Type Product
Octa IAGO48O
4.8
Non-Octa IAGO48N
Octa IAGO60O
6.0
Non-Octa IAGO60N
Octa Non-Octa

Octa Plastic Cylinder - Packing unit : Included cylinder screw (ISOC400)


- Torque recommendation : 30Ncm
Unit : mm
Platform Type Product
Octa IAPY48O
4.8
Non-Octa IAPY48N
Octa IAPY60O
6.0
Non-Octa IAPY60N

SHINSAEGI MEDI-TECH
61
IST & IT System
Octa Abutment and Cylinder Screw - Instrument required 1.2Hex Torque driver
Unit : mm
Code
ISOC40O
Gold Ti

Octa Impression Coping (pick-up) - Packing unit : Included guide pin


Unit : mm
Platform Diameter Type Product
Octa IIPO48O
4.8
Non-Octa IIPO48N
Octa IIPO60O
6.0
Non-Octa IIPO60N

Octa Non-Octa

Guide Pin (pick-up) - Instrument required 1.2Hex Torque driver


Unit : mm
Height (H) Product
15 ISGO15O

Octa Lab Analog Unit : mm


Platform Diameter Product
4.8 ILO40O
6.0 ILO60O

62 SHINSAEGI MEDI-TECH
Prosthetic Flow Diagram For IST And IT System
Overdenture Retained Restoration for O-Ring Abutment

64p 64p
For Denture O-Ring For Laboratory O-Ring
(Red) (Black)

64p

Retainer

64p

O-Ring Lab Analog

64p 68p

O-Ring Abutment O-Ring Abutment Driver


(2.4Hex)

67p

52p 52p 52p

Internal Cover Screw Internal Headless Cover Screw Healing Abutment 1.2Hex Hand Driver

46p 50p

Internal Slightly Fixture(IST) Internal Tapered Fixture(IT)

SHINSAEGI MEDI-TECH
63
IST & IT System
07 O-Ring Abutment - Overdenture restoration
- Multiple implant bone retained and fixed removable overdentures.
- Collar height : 0, 2, 4mm
- Packing unit : Included O-Ring 2ea and O-Ring retainer 1ea
L
- Instrument required O-Ring abutment driver(2.4Hex)
- Torque recommendation : 30Ncm
Unit : mm
Length (L)
D
Diameter (D)
0 2.0 4.0
3.5 IAR400 IAR420 IAR440

O-Ring Unit : mm
Type Code
Red(Denture) IARR002
Black(Laboratory) IARR003

O-Ring Retainer - Female receptacle processed into denture


Unit : mm
Code
IARR001

O-Ring Lab Analog Unit : mm


Code
RL001

64 SHINSAEGI MEDI-TECH
Surgical
Instrument
Esthetic & Innovation

SHINSAEGI MEDI-TECH
SHINSAEGI MEDI-TECH
65
Surgical Instrument

Guide Drill 67p


Straight Drill 67p
Tapered Drill 67p
Hand Driver 67p
Machine Driver 68p
Torque Driver 68p
Fixture Mount Driver 68p
Depth gauge 69p
Drill Extension 69p
Locking Abutment Screw 69p
ALIPS Driver 69p
Positioning Guide 69p
Parallel Pin 69p
Torque Wrench 69p
Holding Key 69p
Bone Profiler & Guide Pin 70p
Path Pin 70p
Reamer Handle 70p
Reamer Guide 70p
Reamer Bite 70p
Bone Mill 70p
Tissue Punch 70p
Drill System 71p
Surgical Drilling Protocol 71p
Drill Dimensions 71p
Surgical Protocol 72p
Surgical Kit Contents 74p

66 SHINSAEGI MEDI-TECH
Surgical Instrument
Guide Drill - This drill has a unique pointed tip, making this an excellent drill for
starting the osteotomy.
Unit : mm
Type Code Application
Lance KRG160 Start drill

Straight Drill - This drills are designed to increase the depth of the osteotomy.
Unit : mm
Diameter Length Code Application
7 KRS2007
9 KRS2009
11 KRS2011
2.0 Depth drill
13 KRS2013
15 KRS2015
17 KRS2017

Tapered Drill - Tapered series of drills follows in order to increase the width of the
osteotomy to correspond to the diameter of the implant being placed.
Unit : mm
Diameter Length Code Application
Short( 7, 9, 11) KRT2028S
2.0/2.8
Long (13, 15, 17) KRT2028L
Short( 7, 9, 11) KRT2033S
2.0/3.3
Long (13, 15, 17) KRT2033L
Short( 7, 9, 11) KRT2136S
2.1/3.6
Long (13, 15, 17) KRT2136L
Short( 7, 9, 11) KRT2540S
2.5/4.0
Long (13, 15, 17) KRT2540L
Width increasing drill
Short( 7, 9, 11) KRT2845S
2.8/4.5
Long (13, 15, 17) KRT2845L
Short( 7, 9, 11) KRT3248S
3.2/4.8
Long (13, 15, 17) KRT3248L
Short( 7, 9, 11) KRT3350S
3.3/5.0
Long (13, 15, 17) KRT3350L
Short( 7, 9, 11) KRT4058S
4.0/5.8
Long (13, 15, 17) KRT4058L

Hand Driver - For use tip-holding function by hand


Unit : mm
Diameter Length Code Application
Short KDH120S Healing abutment, UCLA Abutment
External 1.2Hex
Long KDH120L screw, Internal cover screw
Short KDH090S External cover screw
External 0.9Hex
Long KDH090L (N, R, W, W6.0)
1.2Hex 0.9Hex

SHINSAEGI MEDI-TECH
67
Surgical Instrument
Machine Driver - For use hand-piece of Motor
Unit : mm
Diameter Length Code Application
Short KDM120S Healing abutment, UCLA Abutment
External 1.2Hex
Long KDM120L screw, Internal cover screw
Short KDM090S External cover screw
External 0.9Hex
Long KDM090L (N, R, W, W6.0)

1.2Hex 0.9Hex

- For use Torque Wrench


Torque Driver - For use Torque function
Unit : mm
Diameter Length Code Application
Short KDT120S Healing abutment, UCLA Abutment
External 1.2Hex
Long KDT120L screw, Internal cover screw
Short KDT090S External cover screw
External 0.9Hex
Long KDT090L (N, R, W, W6.0)
Short KDT200S Estheticone and Midicone
Internal 2.0Hex
Long KDT200L Abutment screw
External Type
Short KDT240S
Internal 2.4Hex All of O-Ring Abutment
Long KDT240L
Short KDT270S
Internal 2.7Hex Widecone Abutment screw
Long KDT270L
Short KDTS00S
Solid Driver Solid Abutment
Long KDTS00L
Interal Type Short KDTE00S
Ex-Solid Driver Excellent Solid Abutment
Long KDTE00L
Short KDT300S
Octa Driver Octa Abutment
Long KDT300L

Fixture Mount Driver - For pick-up and delivery of Implant


Unit : mm
Diameter Length Length Code Application
Modrine
Narrow( 3.5)
Hex Long KDMM240L
Hand piece

Regular( 4.1)
Hex Long KDMM270L
Hand piece

Wide( 5.1)
Hex Long KDMM340L
Hand piece For use External implant
Narrow( 3.5) Short KDTM240S (EST Series)
Hex
Ratchet Long KDTM240L
Regular( 4.1) Short KDTM270S
Hex
Ratchet Long KDTM270L
EST SST IST & IT
Wide( 5.1) Short KDTM340S
Hex
Ratchet Long KDTM340L
Torque
All of Size(Sub)
Hex Long KDMM250L
Hand piece For use Submerged Implant
All of Size(Sub) Short KDTM250S (SST Series)
Hex
Ratchet Long KDTM250L
All of Size(Internal)
Octa Long KDMM310L
Hand piece For use Internal implant
All of Size(Internal) Short KDTM310S (IST&IT Series)
EST SST IST & IT Octa
Ratchet Long KDTM310L

68 SHINSAEGI MEDI-TECH
Surgical Instrument
Depth gauge - Measurement of drilling depth(EST, SST, IST, IT Implant)
Unit : mm
Depth Length Code
7, 9, 11, 13, 15, 17 KID170

Drill Extension - For use drill extension on hand-piece


Unit : mm
Code
KIE300

Repositioning Jig - For use locking abutment screw


Unit : mm
Code
KDHAL110

ALIPS Driver - For use ALIPS abutment Unit : mm


Code
KDHAP130

Positioning Guide - Measurement of fixture space


Unit : mm
Width(D) Code
8 KIG080
10 KIG100
D

Parallel Pin - Measurement of direction and situation


Unit : mm
Width(D) Code
4 KIP400
5 KIP500
D

Torque Wrench - Using for insert implant and tie-up driver


Unit : mm
Torque Power Code
15, 25, 35 Ncm KIT450

Holding Key - Holding for Torque Wrench


Unit : mm
Code
KIK850

SHINSAEGI MEDI-TECH
69
Surgical Instrument
Bone Profiler & Guide Pin - For remove from surplus bone
Unit : mm
Fixture platform Interface Diameter Code
3.5 (Narrow) 3.6 KIBN360
4.1 (Regular) 4.15 KIBR415
5.1 (Wide) 5.15 KIBW515
6.0 (W6.0) 6.05 KIBW605
4.8 (N, R, W) 4.85 KIBW485

Path Pin - Measurement of path and gingival height


Unit : mm
Code
KIH250

Reamer Handle Unit : mm


Code
KIRH

Reamer Guide Unit : mm


Width Code
4.5 KIRG450
5.5 KIRG550
6.5 KIRG650

Reamer Bite Unit : mm


Code
KIRB

Bone Mill - For formation of particulate bone with autogenous bone.


Unit : mm
Code
KIBM

Tissue Punch - Flapless surgery


- Laser marking 2, 4, 6mm for easy measurement of gingiva height.
Unit : mm
D Code Application
4.1 KICM410 EST, SST(Narrow)
4.6 KICM460 EST, IT, IST, SST(Regular)
5.3 KICM530 EST, IT, IST, SST(Wide)
6.3 KICM630 EST, SST(Wide 6.0)

70 SHINSAEGI MEDI-TECH
Drill System
Drill (Straight & Tapered Drill)
Straight Drill( 2.0)
Proceed with the initial straight drill to 7mm, 9mm, 11mm, 13mm,
15mm, 17mm with stopper.
2.0mm is designed to increase the depth of the osteotomy.
Thread floss through the hole to prevent accidental swallowing.
2.0 straight drills, the length of the drill tip is 0.5mm.
The length of the drill tip is not included in the depth mark
measurement.
Guide Drill Straight Drill Tapered Drill
Consist of the diameter 2.0mm straight drills are 7. 9. 11, 13, 15,
17mm length with stopper and not marking system.

Tapered Drill ( 2.0/2.8) ( 2.0/3.3) ( 2.1/3.6) ( 2.5/4.0) ( 2.8/4.5) ( 3.2/4.8) ( 3.3/5.0) ( 4.0/5.8) (mm)
A series of tapered drills are width drill in order to increase the width of the osteotomy to correspond to the diameter of
the implant being placed.
Regardless of the tapered drills diameter, the length of the drill tip is 0.3mm
The length of the drill tip is not included in the depth mark measurement.

Surgical Drilling Protocol

Product Platform Body Apex Guide 2.0 2.0/2.8 2.0/3.3 2.1/3.6 2.5/4.0 2.8/4.5 3.2/4.8 3.3/5.0 4.0/5.8
3.5 3.4 2.4
4.1 4.0 2.9
EST 4.1 5.0 3.6
5.1 5.9 4.3
3.8 3.7 2.4
4.3 4.2 2.9
SST 5.0 4.9 3.6
6.0 5.9 4.3
4.8 4.1 2.4 3.4
IST 4.8 4.8 3.4 4.1
IT 6.0 5.3 4.0 4.6

Drill Dimensions
Drill Tip Drill Tip
Drill Diameter Drill Length Drill Diameter Drill Length
Length Length
7mm(with stopper) 7, 9, 11mm(marking with stopper)
2.5/4.0mm(tapered) 0.3mm
9mm(with stopper) 13, 15, 17mm(marking)
11mm(with stopper) 7, 9, 11mm(marking with stopper)
2.0mm(straight) 0.5mm 2.8/4.5mm(tapered) 0.3mm
13mm(with stopper) 13, 15, 17mm(marking)
15mm(with stopper) 7, 9, 11mm(marking with stopper)
3.2/4.8mm(tapered) 0.3mm
17mm(with stopper) 13, 15, 17mm(marking)
7, 9, 11mm(marking with stopper) 7, 9, 11mm(marking with stopper)
2.0/2.8mm(tapered) 0.3mm 3.3/5.0mm(tapered) 0.3mm
13, 15, 17mm(marking) 13, 15, 17mm(marking)
7, 9, 11mm(marking with stopper) 7, 9, 11mm(marking with stopper)
2.0/3.3mm(tapered) 0.3mm 4.0/5.8mm(tapered) 0.3mm
13, 15, 17mm(marking) 13, 15, 17mm(marking)
7, 9, 11mm(marking with stopper)
2.1/3.6mm(tapered) 0.3mm - - -
13, 15, 17mm(marking)

SHINSAEGI MEDI-TECH
71
Surgical Protocol
External Slightly Tapered Fixture (EST System)
01
3.4mm Fixture

15mm

0.5mm Guide 2.0mm 2.0/2.8mm 2.0/3.3mm Fixture


Straight Drill Tapered Drill Tapered Drill

D4Bone : Guide 2.0mm Straight Drill Fixture


D3,D2Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill Fixture
D1Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.0/3.3mm Tapered Drill Fixture

02
4.0mm Fixture

15mm

0.5mm Guide 2.0mm 2.0/2.8mm 2.1/3.6mm 2.5/4.0mm Fixture


Straight Drill Tapered Drill Tapered Drill Tapered Drill

D4Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill Fixture


D3,D2Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture
D1Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill Fixture

03
5.0mm Fixture

15mm

0.5mm Guide 2.0mm 2.0/2.8mm 2.1/3.6mm 2.8/4.5mm 3.2/4.8mm Fixture


Straight Drill Tapered Drill Tapered Drill Tapered Drill Tapered Drill

D4Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture
D3,D2Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill Fixture
D1Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill
3.2/4.8mm Tapered Drill Fixture

04
5.9mm Fixture

15mm

0.5mm Guide 2.0mm 2.0/2.8mm 2.1/3.6mm 2.8/4.5mm 3.3/5.0mm 4.0/5.8mm Fixture


Straight Drill Tapered Drill Tapered Drill Tapered Drill Tapered Drill Tapered Drill

D4Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture
D3,D2Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill
3.3/5.0mm Tapered Drill Fixture
D1Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill
3.3/5.0mm Tapered Drill 4.0/5.8mm Tapered Drill Fixture

72 SHINSAEGI MEDI-TECH
Surgical Protocol
Submerged Slightly Tapered Fixture (SST System)
01
3.7mm Fixture

15mm

0.5mm Guide 2.0mm 2.0/2.8mm 2.0/3.3mm 2.1/3.6mm Fixture


Straight Drill Tapered Drill Tapered Drill Tapered Drill

D4Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill Fixture


D3,D2Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.0/3.3mm Tapered Drill Fixture
D1Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.0/3.3mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture

02
4.2mm Fixture

15mm

0.5mm Guide 2.0mm 2.0/2.8mm 2.1/3.6mm 2.5/4.0mm Fixture


Straight Drill Tapered Drill Tapered Drill Tapered Drill

D4Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.0/3.3mm Tapered Drill Fixture
D3,D2Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture
D1Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill Fixture

03
4.9mm Fixture

15mm

0.5mm Guide 2.0mm 2.0/2.8mm 2.1/3.6mm 2.8/4.5mm 3.2/4.8mm Fixture


Straight Drill Tapered Drill Tapered Drill Tapered Drill Tapered Drill

D4Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture
D3,D2Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill Fixture
D1Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill
3.2/4.8mm Tapered Drill Fixture

04
5.9mm Fixture

15mm

0.5mm Guide 2.0mm 2.0/2.8mm 2.1/3.6mm 2.8/4.5mm 3.3/5.0mm 4.0/5.8mm Fixture


Straight Drill Tapered Drill Tapered Drill Tapered Drill Tapered Drill Tapered Drill

D4Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill Fixture
D3,D2Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill Fixture
3.3/5.0mm Tapered Drill Fixture
D1Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill
3.3/5.0mm Tapered Drill 4.0/5.8mm Tapered Drill Fixture

SHINSAEGI MEDI-TECH
73
Surgical Protocol
Internal Slightly Tapered Fixture (IST System)
Internal Tapered Fixture(IT System)
- IST & IT model are same diameter and same protocol.

01
4.1mm Fixture

15mm

0.5mm Guide 2.0mm 2.0/2.8mm 2.1/3.6mm 2.5/4.0mm Fixture Fixture


Straight Drill Tapered Drill Tapered Drill Tapered Drill (IST) (IT)

D4Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.0/3.3mm Tapered Drill Fixture
D3,D2Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture
D1Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill Fixture

02
4.8mm Fixture

15mm

0.5mm Guide 2.0mm 2.0/2.8mm 2.1/3.6mm 2.5/4.0mm 2.8/4.5mm Fixture Fixture


Straight Drill Tapered Drill Tapered Drill Tapered Drill Tapered Drill (IST) (IT)

D4Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture
D3,D2Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill Fixture
D1Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill
2.8/4.5mm Tapered Drill Fixture

03
5.3mm Fixture

15mm

0.5mm Guide 2.0mm 2.0/2.8mm 2.1/3.6mm 2.8/4.5mm 3.2/4.8mm 3.3/5.0mm Fixture Fixture
Straight Drill Tapered Drill Tapered Drill Tapered Drill Tapered Drill Tapered Drill (IST) (IT)

D4Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill Fixture
D3,D2Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill
3.2/4.8mm Tapered Drill Fixture
D1Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill
3.2/4.8mm Tapered Drill 3.3/5.0mm Tapered Drill Fixture

74 SHINSAEGI MEDI-TECH
Surgical Kit

External Kit (EST)

Internal Kit (SST, IST, IT)

SHINSAEGI MEDI-TECH
75
Surgical Kit Contents
External Kit(EST) Internal Kit(SST, IST, IT)
No Type Length Q'Ty Application No Type Length Q'Ty Application
1 Guide Drill 1 Start Drill 1 Guide Drill 1 Start Drill
2.0 Straight Drill 7mm 1 Depth Drill 2.0 Straight Drill 7mm 1 Depth Drill
2.0 Straight Drill 9mm 1 Depth Drill 2.0 Straight Drill 9mm 1 Depth Drill
2.0 Straight Drill 11mm 1 Depth Drill 2.0 Straight Drill 11mm 1 Depth Drill
2 2
2.0 Straight Drill 13mm 1 Depth Drill 2.0 Straight Drill 13mm 1 Depth Drill
2.0 Straight Drill 15mm 1 Depth Drill 2.0 Straight Drill 15mm 1 Depth Drill
2.0 Straight Drill 17mm 1 Depth Drill 2.0 Straight Drill 17mm 1 Depth Drill
3 2.0/2.8 Tapered Drill(S) 11mm 1 Width Increasing Drill 3 2.0/2.8 Tapered Drill(S) 11mm 1 Width Increasing Drill
4 2.0/2.8 Tapered Drill(L) 17mm 1 Width Increasing Drill 4 2.0/2.8 Tapered Drill(L) 17mm 1 Width Increasing Drill
5 2.0/3.3 Tapered Drill(S) 11mm 1 Width Increasing Drill 5 2.0/3.3 Tapered Drill(S) 11mm 1 Width Increasing Drill
6 2.0/3.3 Tapered Drill(L) 17mm 1 Width Increasing Drill 6 2.0/3.3 Tapered Drill(L) 17mm 1 Width Increasing Drill
7 2.1/3.6 Tapered Drill(S) 11mm 1 Width Increasing Drill 7 2.1/3.6 Tapered Drill(S) 11mm 1 Width Increasing Drill
8 2.1/3.6 Tapered Drill(L) 17mm 1 Width Increasing Drill 8 2.1/3.6 Tapered Drill(L) 17mm 1 Width Increasing Drill
9 2.5/4.0 Tapered Drill(S) 11mm 1 Width Increasing Drill 9 2.5/4.0 Tapered Drill(S) 11mm 1 Width Increasing Drill
10 2.5/4.0 Tapered Drill(L) 17mm 1 Width Increasing Drill 10 2.5/4.0 Tapered Drill(L) 17mm 1 Width Increasing Drill
11 3.2/4.8 Tapered Drill(S) 11mm 1 Width Increasing Drill 11 2.8/4.5 Tapered Drill(S) 11mm 1 Width Increasing Drill
12 3.2/4.8 Tapered Drill(L) 17mm 1 Width Increasing Drill 12 2.8/4.5 Tapered Drill(L) 17mm 1 Width Increasing Drill
13 3.3/5.0 Tapered Drill(S) 11mm 1 Width Increasing Drill 13 3.2/4.8 Tapered Drill(S) 11mm 1 Width Increasing Drill
14 3.3/5.0 Tapered Drill(L) 17mm 1 Width Increasing Drill 14 3.2/4.8 Tapered Drill(L) 17mm 1 Width Increasing Drill
15 4.0/5.8 Tapered Drill(S) 11mm 1 Width Increasing Drill 15 3.3/5.0 Tapered Drill(S) 11mm 1 Width Increasing Drill
16 4.0/5.8 Tapered Drill(L) 17mm 1 Width Increasing Drill 16 3.3/5.0 Tapered Drill(L) 17mm 1 Width Increasing Drill
17 Drill extension 1 For use drill and handpiece tools extension 17 Drill extension 1 For use drill and handpiece tools extension
18 Fixture Mount Driver(Machine) Narrow 1 Mountless delivery for External 18 Fixture Mount Driver for Machine(Hex)(L) 1 Mountless delivery for Internal Hex(SST)
19 Fixture Mount Driver(Machine) Regular 1 Mountless delivery for External 19 Fixture Mount Driver for Torque (L) 1 Mountless delivery for Internal Hex(SST)
20 Fixture Mount Driver(Machine) Wide 1 Mountless delivery for External 20 Fixture Mount Driver for Torque (S) 1 Mountless delivery for Internal Hex(SST)
21 Fixture Mount Driver(Torque) Narrow(L) 1 Mountless delivery for External 21 Fixture Mount Driver for Machine(Octa)(L) 1 Mountless delivery for Internal Octa(IST/IT)
22 Fixture Mount Driver(Torque) Narrow(S) 1 Mountless delivery for External 22 Fixture Mount Driver for Torque (L) 1 Mountless delivery for Internal Octa(IST/IT)
23 Fixture Mount Driver(Torque) Regular(L) 1 Mountless delivery for External 23 Fixture Mount Driver for Torque (S) 1 Mountless delivery for Internal Octa(IST/IT)
24 Fixture Mount Driver(Torque) Regular(S) 1 Mountless delivery for External 24 Hex 1.2 Driver for Hand(L) 1 Cover Screw, Abutment Screw
25 Fixture Mount Driver(Torque) Wide(L) 1 Mountless delivery for External 25 Hex 1.2 Driver for Hand(S) 1 Healing Abutment,
26 Fixture Mount Driver(Torque) Wide(S) 1 Mountless delivery for External 26 Hex 1.2 Driver for Machine(L) 1 6.0 Excellent Solid Abutment,
27 Hex 0.9 Driver for Hand(L) 1 27 Hex 1.2 Driver for Machine(S) 1 Locking Abutment Screw,
28 Hex 0.9 Driver for Hand(S) 1 28 Hex 1.2 Driver for Torque(L) 1 In-Octa Cemented Abutment,
29 Hex 0.9 Driver for Machine(L) 1 External Cover Screw 29 Hex 1.2 Driver for Torque(S) 1 Sub Solid Abutment, Cylinder Screw
30 Hex 0.9 Driver for Machine(S) 1 (N, R, W, W6.0) 30 Octa Driver for Torque(L) 1
Octa Abutment
31 Hex 0.9 Driver for Torque(L) 1 31 Octa Driver for Torque(S) 1
32 Hex 0.9 Driver for Torque(S) 1 32 Solid Driver for Torque(L) 1
Solid Abutment
33 Hex 1.2 Driver for Hand(L) 1 33 Solid Driver for Torque(S) 1
34 Hex 1.2 Driver for Hand(S) 1 Abutment Screw 34 Excellent Solid Driver for Torque(L) 1
Excellent Solid Abutment
35 Hex 1.2 Driver for Machine(L) 1 Healing Abutment, 35 Excellent Solid Driver for Torque(S) 1
36 Hex 1.2 Driver for Machine(S) 1 Locking Abutment Screw, 36 Hex 2.4 Driver for Torque(L) 1
O-Ring Abutment
37 Hex 1.2 Driver for Torque(L) 1 Cylinder Screw 37 Hex 2.4 Driver for Torque(S) 1
38 Hex 1.2 Driver for Torque(S) 1 4mm 1
38 Parallel Pin Measurement of direction and situation
39 Hex 2.0 Driver(L) 1 For Estheticone, Midicone 5mm 1
40 Hex 2.0 Driver(S) 1 For Estheticone, Midicone 8mm 1
39 Positioning Guide Measurement of fixture space
41 Hex 2.7 Driver(L) 1 For Widecone 10mm 1
42 Hex 2.7 Driver(S) 1 For Widecone 40 Torque Wrench 45N cm 1 Insert implant and tie-up driver
43 Hex 2.4 Driver(L) 1 For O-Ring 41 Holding Key 1 Holding for Torque Wrench
44 Hex 2.4 Driver(S) 1 For O-Ring 42 Depth Gauge 7~17mm 1 Measurement of drilling depth
4mm 1 Measurement of direction and situation Total 49
45 Parallel Pin
5mm 1 Measurement of direction and situation
8mm 1 Measurement of fixture space
46 Positioning Guide
10mm 1 Measurement of fixture space
Option
47 Torque Wrench 45N cm 1 Insert implant and tie-up driver No Type Length Q'Ty Application
48 Holding Key 1 Holding for Torque Wrench 3.6 1
49 Depth Gauge 7~17mm 1 Measurement of drilling depth 4.15 1
Total 56 1 Bone Profile and Guide Pin 5.15 1 For remove from surplus bone.
6.05 1
4.85 1
2 Path Pin 1 Measurement of path and height gingiva
3 Reamer Handle 1
4.5 1
4 Reamer Guide 5.5 1
6.5 1
5 Reamer Bite 1
6 Bone Mill 1 For Particulate bone generation by autogenous bone.
4.1 1 Flaplees Surgery for EST, SST (Narrow)
4.6 1 Flaplees Surgery for EST, IT, IST, SST(Regular)
7 Tissue punch
5.3 1 Flaplees Surgery for EST, IT, IST, SST(Wide)
6.3 1 Flaplees Surgery for EST, SST(Wide 6.0)

76 SHINSAEGI MEDI-TECH
Total 16