Professional Documents
Culture Documents
(MIS) Seven Catalogue
(MIS) Seven Catalogue
P.4-5
P.6-7
P.8
P.9
P.10
P.11
P.12
P.13
P.14-15
P.16-17
P.18-19
P.20-21
MIS Warranty:
MIS exercises great care and effort in maintaining the superior quality of its
products. All MIS products are guaranteed to be free from defects in material
and workmanship. However, should a customer find fault with any MIS product
after using it according to the directions, the defective product will be replaced.
produced, transcribed, stored in an electronic retrieval system, translated into any language or computer language, or
be transmitted in any form whatsoever, without the prior written consent of the publisher.
Introduction
Advantages
Implant range
Implants 3.75mm
Implants 4.20mm
Implants 5mm
Implants 6mm
Mountless
Restorative procedure
Success
Analysis reports
Packaging
4.
Advantages.
Successful
High success rate, provided by a combination of advanced
geometric design and new surface morphology.
Forgiving
SEVEN is designed for implantation in a wide range of bone
types and bone augmentation procedures.
Simple
A specially designed final drill is supplied with every implant,
allowing a short and safe drilling procedure.
Easy
Increased insertion speed is provided by a dual thread
of 2.4mm, combined with self-drilling capability.
Initial Stability
The thread thickness changes from the apex to the neck with the
same pitch, improving the compression of the bone during insertion.
Micro Rings on the implant neck provide better initial stability by
improving the interfacial shear strength at the crestal zone.
Self-Tapping
SEVEN cuts its own threads during implantation, minimizing friction-generated
heat. Three spiral channels running the length of the fixture fill with bone chips
during implantation to improve integration.
8.
Screw type
implant range
Standard and wide platform.
Standard
Ø 4mm
Wide
Implants cover
MF7-08500 MF7-10500 MF7-11500 MF7-13500 MF7-16500 screws and
healing caps.
Ø 5mm Available in gingival
heights: 3,4,5,6mm
Screw type
implant wide
platform
MC1-00470
Screw type
implant wide
platform Ø 6.3mm
3/4/5mm MH-W3630
MH-W4630
MH-W5630
9.
length 10mm
Ø 3.60 Ø 3.75
MF7-11375 Ø 3.75mm
length 11.50mm
MF7-13375 Ø 3.75mm
length 13mm Ø 2.80 Ø 3.10
Final Drill
A specially designed final drill for
8mm, 10mm, 11.50mm, 13mm and
MF7-16375 Ø 3.75mm 16mm implants is supplied with every
length 16mm implant, allowing a short and safe
drilling procedure.
* all implants include the relevant fixture, cover screw and final drill
2.45
MF7-10420 Ø 4.20mm
length 10mm
Ø4.10
Ø 3.75
0.4mm
MF7-11420 Ø 4.20mm Ø 4.20
length 11.50mm
MF7-13420 Ø 4.20mm
length 13mm Ø3.30 Ø 3.70
Final Drill
A specially designed final drill for
8mm, 10mm, 11.50mm, 13mm and
MF7-16420 Ø 4.20mm 16mm implants is supplied with every
length 16mm implant, allowing a short and safe
drilling procedure.
* all implants include the relevant fixture, cover screw and final drill
OR
21.
2.45
MF4-10500 Ø 5mm
length 10mm
Ø 4.90
Ø 4.50
0.4mm
MF7-11500 Ø 5mm Ø 5
length 11.50mm
MF7-13500 Ø 5mm
length 13mm Ø 4.10 Ø 4.50
Final Drill
A specially designed final drill for
8mm, 10mm, 11.50mm, 13mm and
MF7-16500 Ø 5mm 16mm implants is supplied with every
length 16mm implant, allowing a short and safe
drilling procedure.
* all implants include the relevant, cover screw and final drill
Seven
14. screw type implants
Ø 6mm wide platform.
2.45
MF7-10600 Ø 6mm
length 10mm
Ø 5.90
Ø 4.50
0.4mm
MF7-11600 Ø 6mm
length 11.50mm Ø 6
MF7-13600 Ø 6mm
length 13mm
Ø 5.10 Ø 5.50
Final Drill
A specially designed final drill for 8mm,
10mm, 11.50mm and 13mm implants is
supplied with every implant, allowing a
short and safe drilling procedure.
* all implants include the relevant fixture, cover screw and final drill
OR
Mountless.
MountLess Tube.
14. Restorative Procedure
INTERNAL HEXAGON.
Cover Screw Healing Caps Multi units/Ball attachments Impression Coping Analogs Temporary
Cylinders
Ø3.75
MH-53375 MD-IC200 MD-S0220 MD-TCH13
MF7-08500 MH-54375
MF7-10500 MH-55375
MF7-11500 MH-56375
MF7-13500
MF7-16500
MM-MTP53
Standard Platform
MD-PF375
MB-N1375 MB-RS375
MB-N2375
Ø4.20 MB-N3375
MB-N4375
MF7-08420 MB-N5375
MF7-10420
MF7-11420
MF7-13420 Śruba MM-CT480 MA-RSM10
MF7-16420 zabliźniająca
MA-S1375 MH-00450
MA-S2375 MM-MTP53
MA-S3375
MA-S4375
MW-IC200
Ø5 MH-W3630
MH-W4630
MF7-08500 MH-W5630
MF7-10500
MF7-11500
MF7-13500 MM-MTP53 MD-S0220
MF7-16500
Wide Platform
MW-PF550
MW-B1500 MB-RS375
MW-B3500
MW-B5500
Ø6
MF7-08600
MF7-10600 Śruba MM-CT480 MA-RSM10
MF7-11600 zabliźniająca
MF7-13600
MA-W1500 MH-00450
MA-W2500
MA-W3500 MM-MTP53
MA-W4500
Optional screws:
MD-S0200
MD-S0220
MD-G0220
MD-S0222
MD-S0224
Prosthetic Options
MM-BGC45
MM-BGC45
16.
Success.
10
Hebrew University
Jerusalem, Israel, IADR
5 August 03, 2004
Ma
ch
ine
17.
Im SE
VE
pla N
nt
Micro Structure Micro rings (0.1x0.3) on the
Micro Rings neck provide a better initial
stability by improving the
interfacial shear strength
in the crestal zone.
18.
Surface.
The surface roughness over the entire body, together
with the high level of surface morphology, prevents
bone resorption at the implants’ neck.
Roughness Measurement
The arithmetic average of the deviation Ra is the most commonly used
measurement for surface roughness. The micro geometry of MIS implants
meet the roughness recommended in the international literature.
Instrument:
Parthometer M1
(MAHR)
Ra 2.25micron
Rz 14.65micron
Rmax 15.5micron
R profile 0.25mm
Lt 5.60mm
Lc 0.80mm
Pc (0.5-0.5) 165/c
19.
Analysis Reports
XPS analysis conditions
For surface analysis, the samples were irradiated with monochromatic X-rays. Survey spectra were
recorded with a pass energy of 100e V, through which the surface chemical composition was deter-
mined. The atomic concentrations were calculated using elemental sensitivity factors without applying
any standardization procedure. The core level binding energies of the different peaks were normalized
by setting the binding energy for the Cls at 284.5 eV.
For each of the screws, one flat edge area, marked as #1, was analyzed in the as-received state only:
Table 1
XPS Atomic Concentrations (%) for LOT 83
Implants C Ti O N Ca Si S Cl Na Al Cu Mg P V
MF7-13420, thread area 1 25.54 18.19 51.42 0.37 0.92 0.1 - - - 2.91 - 0.27 - 0.28
MF7-13420, thread area 2 28.71 15.99 49.16 0.39 1.00 - - - 0.3 4.04 - - - 0.41
MF7-13375, thread area 1 24.31 19.45 52.71 - - - - 0.12 - 3.08 - - - 0.33
MF7-13375, thread area 2 27.78 16.11 51.31 0.21 0.05 - - 0.78 3.60 - - - 0.16
Table 2
Ti Oxide Thickness (nm) for LOT 83
Interpretation of Results:
No strange elements or traces thereof were identified. This means that the surface treatment
(etching) did not leave undesired effects. The C/Ti ratio classified the implants as “normal”. The
ratio admitted is where Ti is 15% and C is 30%.
Packaging.
The packaging is designed for ease of use
by the dentist and the distributor.
White
6
Cover screw
Implant