SPECIFICATIONS Bridge Panel Cabin Panel

Model BR-1000 BR-1010 BR-1030


GENERAL 2.1 kg 4.6 lb 0.3 kg 0.7 lb 18.5 0.7" 65.5 2.6"
Standards IMO MSC. 128(75)
9.5 0.4"
264 10.1" 21 0.8"
BRIDGE PANEL
250 9.8" 123 4.8"
Screen Size 7" color LCD 114 4.5"
Pixel Number 480 x 234

120 4.7"
PROCESSOR UNIT

75 3.0"
145 5.7"

196 7.7"
178 7.0"
LAN 100base-TX
Input Alarm Input 48 ch 4- 5
Local ACK 12 ch 30
Operator's Fitness 7 ch
Autopilot Mode Auto Mode 1 ch 82 3.2"
TCS Mode 1 ch 100 3.9"
Power Fail 1 ch
Panel Test 1 ch Bridge Panel (Flush Mount Type) Timer Reset Panel
Output Remote ACK 12 ch
2 ch
BR-1010 BR-1040
System Failure
External Alarm 1 ch 1.9 kg 4.1 lb 39 75
0.3 kg 0.7 lb 18.5 0.7" 65.5 2.6"
250 9.8" 1.5" 3.0"
MODBUS 2 ch 9.5 0.4"
Cabin Panel Control Output 12 VDC

145 5.7"
Duty Lamp
Alarm Lamp
Buzzer

120 4.7"
75 3.0"
Timer Reset Panel Control Output 12 VDC
61 2.4" 110 4.3" 61 2.4"
Watch Alarm Lamp 4- 5
Bridge Alarm Lamp

2.5" 2.5"

118 4.6"
63
Buzzer
4.5
Input Timer Reset 63
0.2" 82 3.2"
CABIN PANEL 100 3.9"
Input 12 VDC 6-R2.25
221 8.7"
Duty Lamp
Alarm Lamp Processor Unit Watertight Timer Reset Panel
Buzzer BR-1020 BR-1060 28.5
Output Panel Test 13.0 kg 28.6 lb 0.9 kg 1.9 lb 1.1" 88 3.5"

TIMER RESET PANEL 440 17.3"


12 0.5"

21 0.8"
12 0.5"
Input 12 VDC 360 14.1"
158 6.2"
Watch Alarm Lamp 2- 11 155 6.1"
Bridge Alarm Lamp
Buzzer

160 6.3"
Output Timer Reset
354 13.9"
368 14.5"
392 15.4"

POWER SUPPLY
PR-240 24 VDC

ENVIRONMENT R6
125 4.9"
Temperature (IEC 60945-4) Bridge Panel -15°C to +55°C 12 0.5"
360 14.1"
Processor Unit -15°C to +55°C
Cabin Panel -15°C to +55°C

Waterproofing (IEC 60529)


Timer Reset Panel
Watertight Timer Reset Panel
Bridge Panel
Processor Unit
Cabin Panel
-15°C to +55°C
-25°C to +55°C
Front: IP22 Back: IP20
IP20
Front: IP22 Back: IP20
INTERCONNECTION DIAGRAM
3A
Fuse
24 VDC
Power
AC/DC
Power Supply
PR-240
100-115/
24 VDC
BR-1000
Timer Reset Panel Front: IP22 Back: IP20 Bridge Panel Distribution 200-230 VAC
LAN

Box
Watertight Timer Reset Panel Front: IP56 Back: IP20 BR-1010
Vibration (IEC 60945-4) HUB
HUB-101
EQUIPMENT LIST
LAN

Model BR-1000
Standard
2nd
1 Bridge Panel BR-1010 1 unit Processor Unit Processor Unit
BR-1020
2 Processor Unit BR-1020 1 unit BR-1020
3 Cabin Panel BR-1030 1-14 unit(s)
4 Timer Reset Panel BR-1040 1-4 unit(s)
MODBUS x 2ch

Alarm Inputs, Local ACK

Operator Presence

5 AC-DC Power Supply Unit PR-240 1 unit


Remote ACK

6 Cable (3.5 m) with 3A Fuse MJ-A3SPF0013-035 (3A) 1 set Junction Box


Operator Presence, Autopilot Mode

1 set (Local supply)


7 Installation Materials and Spare Parts
System Fail, External Alarm
Alarm Inputs, Local ACK

Option
Remote ACK

- Processor Unit .........


BR-1020 *Max. 2 units in one system
- HUB HUB-101 *Necessary if 2 Processor Units are equipped
- Cabin Panel BR-1030 External Equipment
- Timer Reset Panel BR-1040 VDR ......... IAS

- Watertight Timer Reset Panel BR-1060


- Bracket for BR-1010 with Installation Materials Timer Reset Panel/
Watertight Timer Reset Panel
(BR-1040 / BR-1060)
Cabin Panel
BR-1030
External Equipment
Option or Local Supply

All brand and product names are registered trademarks, trademarks


or service marks of their respective holders.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

FURUNO ELECTRIC CO., LTD. FURUNO ESPAÑA S.A. FURUNO SVERIGE AB FURUNO DEUTSCHLAND GmbH 09103U Printed in Japan
Nishinomiya, Hyogo, Japan Madrid, Spain Västra Frölunda, Sweden Rellingen, Germany
www.furuno.co.jp www.furuno.es www.furuno.se www.furuno.de
Catalogue No. M-1543
FURUNO U.S.A., INC. FURUNO DANMARK AS FURUNO FINLAND OY FURUNO EURUS LLC
Camas, Washington, U.S.A. Hvidovre, Denmark Espoo, Finland St. Petersburg, Russian Federation
www.furunousa.com www.furuno.dk www.furuno.fi www.furuno.com.ru
FURUNO (UK) LIMITED FURUNO NORGE A/S FURUNO POLSKA Sp. Z o.o. FURUNO HELLAS LTD.
Havant, Hampshire, U.K. Ålesund, Norway Gdynia, Poland Piraeus, Greece
www.furuno.co.uk www.furuno.no www.furuno.pl www.furuno.com
FURUNO FRANCE S.A.S.
Bordeaux-Mérignac, France
www.furuno.fr
FURUNO’s Bridge Alarm System manages the onboard
equipment alarms and monitors watch officer’s
presence for early detection of emergency

Bridge alarm system


The BR-1000 monitors the equipment
alarms and presents the equipment status
in the Bridge Panel.
Normal (No Alarm) Mode
Bridge Panel Cabin Panel Timer Reset Panel Watertight Timer Reset Panel 1. When an equipment alarm is activated, the Bridge Panel
automatically displays a list of the equipment generating
alarm. “Bridge Alarm” icon flashes and the alarm is
generated in 30 seconds. (First Stage)
2. If the alarm is not acknowledged in the First Stage, the
BR-1000 transmits the alarm to the selected Cabin Panels.
The list of the equipment
(Second Stage)
generating alarm is shown, and
3. If the alarm is not acknowledged within the pre-set time, the “Bridge Alarm” icon flashes.
sMeets IMO resolution MSC.128(75) for “Bridge Navigational Watch Alarm System” system transmits the alarm to all Cabin Panels. (Third Stage)
sCollectively manages and presents the alarm information on the display unit 4. The buzzer stops when the officer presses the [BUZ STOP] /
sAlarm information is sorted and displayed according to the set priority [ACK] button. When the cause of the alarm is removed, the
Bridge Panel returns to the normal mode. The buzzer stops when the officer
sWatch Safety System to monitor the watch officer’s presence to minimize failure at avoiding
presses the [BUZ STOP] / [ACK] button.
approaching danger
However, if the problem is not resolved,
sTransmits alarm to the backup officer in accommodation, if watch officer fails to respond to the the equipment name and “Bridge Alarm”
active alarm or emergency call icon will be shown in a different color.
s3 operation modes available: One-Man, Bridge Attended and Harbour When the problem is resolved, the
display turns to the normal mode.
Watch safety system
The Bridge Alarm System BR-1000 collectively controls the Cabin Panels installed other sections of the vessels in order The BR-1000 detects the watch officer’s
warning notice from equipment onboard and monitors watch to inform backup officers of the watch officer’s absence.
presence to ensure constant watch.
officer’s presence for maritime casualty avoidance. The 1. While the watch safety system is active, the watch officer in
The BR-1000 offers 3 operation modes: One-man, Bridge
BR-1000 performs the following two functions: Bridge alarm the wheelhouse have to press the button on Timer Reset
Attended and Harbour. In One-Man operation mode, both
system and Watch safety system. Panel or operate interfaced equipment at certain intervals.
bridge alarm system and watch safety system work. In
(3-12 min.)
In the bridge alarm system function, the Bridge Panel of the Bridge Attended mode, visual and audible alarm will be If the watch officer does not press the button on Timer Reset The progress bar at bottom left
BR-1000 in the wheelhouse generates the visual and audible generated in the wheelhouse, but the alarm will not Panel or operate interfaced equipment, the Bridge Panel and marked out by degrees.
alarms upon the equipment alarm’s activation. If the alarm is transferred to the Cabin Panels. In Harbour mode, visual the Timer Reset Panel generate the visual and audible
not acknowledged at this stage, the BR-1000 will transmit the alarm will be activated only on the Bridge Panel in the alarms in 30 seconds. (First Stage)

alarm to the Cabin Panels in other sections of the vessel. wheelhouse, not be transferred to the Cabin Panels. 2. If the alarm is not acknowledged in the First Stage, the
BR-1000 transmits the alarm to the selected Cabin Panels in
Also, the BR-1000 monitors the watch officer’s presence The BR-1000 meets the IMO MSC. 128(75). The Processor the back-up officer’s room and pubic room. (Second Stage)
through watch safety system function. A watch officer is Unit has total of 48 ports to interface the equipment onboard
3. If the alarm is not acknowledged within the pre-set time, the If the watch officer does not press the
required to press any keys of the equipment or Timer Reset and watches their alarm status. It also has 7 ports for the system transmits the alarm to all Cabin Panels. (Third Stage) button on Timer Reset Panel or
Panel at certain intervals. When the officer fails to press the operator’s presence inputs. Watertight Timer Reset Panel operate interfaced equipment, the panel
4. The buzzer stops when the officer presses the [BUZ STOP] /
key within pre-set intervals, the visual and audible alarms will can also be selected (optional supply). Up to 14 Cabin [ACK] button. The Bridge Panel will reset the timer and show will turn to the visual alarm mode.
be generated in the wheelhouse. If the officer doesn’t Panels can be installed on a ship. the normal mode, when the alarm is acknowledged by the
respond to the alarm, the BR-1000 transmits the alarm to the watch officer.