Convex Optimization of Integrated Power-Gas Energy Flow Model With Applications To Probabilistic Energy Flow
Convex Optimization of Integrated Power-Gas Energy Flow Model With Applications To Probabilistic Energy Flow
fully edited. Content may change prior to final publication. Citation information: DOI 10.1109/TPWRS.2020.3018869, IEEE
Transactions on Power Systems
Abstract—Energy flow calculation is a fundamental problem of IPGS planning was presented based on the Elitist
the integrated power and gas system (IPGS) operation and Non-dominated Sorting Genetic Algorithm II (NSGA-II) [8].
planning. However, the nonlinear gas flow model introduces Considering the gas storage, a detailed IPGS reliability model
major challenges to the energy flow calculation. In this paper, we was established to provide limiting conditions for the IPGS
propose a tractably convex optimization model to solve the energy
flow problem in IPGSs. It is demonstrated that the proposed
planning [9]. Reference [10] formulated a multi-stage
optimization model has the same optimal solution as the original stochastic programming model with non-anticipativity
nonlinear steady energy flow model. Also, piecewise linearization constraints to refine planning decisions dynamically at various
is adopted to tightly linearize the nonlinear objective function of stages for improving the accuracy of the expansion planning
the model, which transforms the formulated convex optimization model. Reference [11] developed a reliability-based optimal
into a linear program one. Thus, the computation complexity of planning model, where a minimal cut-maximal flow algorithm
the proposed energy flow model is significantly reduced as was adopted to analyze the network flow and transfer
compared with the existing methods. In addition, the proposed capabilities.
model can be extended to probabilistic energy flow estimation. In [12], an optimal energy flow model in IPGS was proposed
Extensive case studies are conducted to validate the effectiveness
of the proposed energy flow model using three IPGSs.
by considering N-1 network security constraints. In [13], a
security-constrained unit commitment model with dynamic gas
constraints was formulated, where the impacts of natural gas
Index Terms—Integrated power and gas system, nonlinear gas stored in pipelines was taken into account. The coordination
flow, convex optimization, piecewise linearization, probabilistic between distributed gas-fired generators and power-to-gas
energy flow estimation. equipment in an IPGS was exploited to enhance the
accommodation of various renewable energy resources [14].
I. INTRODUCTION The uncertainties associated with the increasing penetration of
0885-8950 (c) 2020 IEEE. Personal use is permitted, but republication/redistribution requires IEEE permission. See http://www.ieee.org/publications_standards/publications/rights/index.html for more information.
Authorized licensed use limited to: Cornell University Library. Downloaded on August 25,2020 at 17:20:00 UTC from IEEE Xplore. Restrictions apply.
This article has been accepted for publication in a future issue of this journal, but has not been fully edited. Content may change prior to final publication. Citation information: DOI 10.1109/TPWRS.2020.3018869, IEEE
Transactions on Power Systems
gas pipeline flow equations and compressor pressure equations. modeling that can address the pressure loss adopted the
A piecewise linearization is adopted, which ensures a tight absolute pressure boost n m [21], which means that the
linear program for the nonlinear model. The main contributions compressor can precisely boost the pressure on the origin node
of this paper are summarized as follows: to a certain value, which can be formulated as
1) A tight linear program model is proposed to find the steady n m nm mn nm , nm (3)
energy flow solution by considering pipelines and compressors.
Compared with existing methods, the proposed model has three where is the set of compressors, nm is the squared
advantages: (i) initial value can be arbitrary; (ii) convergence is pressure loss of compressor mn, nm is the absolute pressure
guaranteed. The energy flow will be attainable if the boost of compressor mn, and nm is the absolute squared
optimization model is feasible; and (iii) computation burdens pressure boost considering the pressure loss of compressor
are significantly reduced since the proposed model is mn.
formulated as a P-problem rather than a NP-hard problem. 3) Nodal Gas Flow Balance: Nodes in the gas network include
2) The steady-stage probabilistic energy flow model is set up those of source, load, and slack. For each node, the inlet gas
based on the convex optimization, where the probabilistic input flow is equal to outlet gas flow, stated as
boundary condition is sampled and the probability distribution
of the energy flow is obtained using Monte Carlo Simulation. fmn f nm Gm Dm , m (4)
mnGF nmGT
The rest of the paper is organized as follows. Section II where GF/GT are the sets of gas pipelines with m as the
presents the detailed modeling of the IPGS. Section III origin/end node, Gm and Dm are the gas source and load at
proposes the convex optimization model for solving the
node m, respectively, and is the set of gas nodes. Also, one
nonlinear gas equations, which can be transformed into a tight
linear program model using the piecewise linearization. Section node is selected as slack node to provide the reference node
IV demonstrates the extension to the probabilistic energy flow pressure, which is considered to be constant [21]:
model. Section V presents the numerical results on three IPGSs. o const (5)
Section IV concludes. where o represents the given slack node.
B. Model of Power System
II. MODELING OF INTEGRATED POWER AND GAS SYSTEMS
A linear power flow model is presented in (6), where
A. Model of Gas System (6a)-(6b) ensure active and reactive power balances at each
The gas system, including natural gas, hydrogen, carbon power system bus; (6c) and (6d) describe voltage magnitudes at
dioxide, is composed of gas pipelines, compressor stations, gas PV and slack buses, and the phase angle of slack bus,
sources and gas loads. The gas from the sources is transferred to respectively [27].
gas loads through pipelines in which the gas nodal pressure can n n
drop due to friction losses against inner walls, which might PGic PGig PLi GijV j Bij' j , i (6a)
j 1 j 1
impair the normal operation. Thus, compressor stations are
n n
built at certain nodes to maintain the nodal pressure. c
QGi g
QGi QLi BijV j Gij j , i (6b)
1) Pipeline Model: The gas flow in each pipeline is determined j 1 j 1
by the nodal pressure at both ends of the pipeline. For long
pipelines, The Weymouth, Panhandle A, and Panhandle B Vi const , i (6c)
equations were developed to characterize the relationship i const , i (6d)
between gas flow and pressure, as stated in [24],[25]: where n is the number of power system buses, is the set of
f mn sign f mn Cmn pm2 pn2 Cmn m n , mn (1)
PQ buses, and are the sets of PV and slack buses,
and sign() is defined by respectively, Vi and θi are voltage magnitude and angle at bus i;
1 f mn 0 respectively, PGic / QGi
c
and PGig / QGi
g
are active/reactive power
sign f mn (2)
1 f mn 0 outputs of coal-fired and gas-fired generators at bus i,
where is the set of gas pipelines, m and n are the origin and respectively, PLi and QLi are active and reactive electric loads at
bus i, respectively, Yij and Yij’ are elements in the i-th row and
end nodes for gas pipeline mn, respectively, fmn is the gas flow the j-th column of Y (admittance matrix) and Y’ (admittance
through pipeline mn; pm and pn are the nodal pressures of nodes matrix without shunt elements), respectively, Gij and Bij are real
m and n, respectively, is a constant scalar larger than 1 (e.g., and imaginary parts of Yij, respectively, Gij’ and Bij’ are real and
= 2 in Weymouth equation, = 1.8545 in Panhandle A imaginary parts of Yij’, respectively.
equation and = 1.9607 in Panhandle B equation), Cmn is the
pipeline constant related to temperature, length, diameter, C. Coupling Equations of IPGS
friction, and etc., and π represent the squared nodal pressure p2 . The IPGS is closely coupled by gas-fired units. In general,
2) Compressor Model: The mathematical relationship between changes in gas demand resulted from changes in electricity
inlet and outlet pressures in a compressor can be specified in generation set points are expected to trigger the effects of the
several ways. A rough estimate used for planning model can be Brayton cycle as a result of the pressure differences. This may
expressed by the compression ratio πm/πn without considering affect the production rates. In this paper, we consider that
the pressure loss inside the compressor station [26]. Another production rates are constant for the convexity hypothesis
0885-8950 (c) 2020 IEEE. Personal use is permitted, but republication/redistribution requires IEEE permission. See http://www.ieee.org/publications_standards/publications/rights/index.html for more information.
Authorized licensed use limited to: Cornell University Library. Downloaded on August 25,2020 at 17:20:00 UTC from IEEE Xplore. Restrictions apply.
This article has been accepted for publication in a future issue of this journal, but has not been fully edited. Content may change prior to final publication. Citation information: DOI 10.1109/TPWRS.2020.3018869, IEEE
Transactions on Power Systems
Dm V , , m (15c)
solution *
f mn mn and multipliers m* m are
N mn N mn
obtained using the KKT conditions, which are stated as:
* * *
f mn (i )
f mn i , i =1, i 0,1 , mn (15d)
LDmV , ( fmn ) fmn sign( f mn ) i 1 i 1
m* n* 0, mn (11a) Since the objective function in (15a) is perturbed by the
fmn Cmn number of segments Nmn, the above linear program (15) is not
* degenerated and it has a unique optimal solution. The optimal
LDm V , ( f mn )
mn m* n* 0, mn (11b) solution of the linearized model (15) is stated as
f mn
V , , f
i
* *
i
*
mn ,
m* ,i* , in which the power system solution
0885-8950 (c) 2020 IEEE. Personal use is permitted, but republication/redistribution requires IEEE permission. See http://www.ieee.org/publications_standards/publications/rights/index.html for more information.
Authorized licensed use limited to: Cornell University Library. Downloaded on August 25,2020 at 17:20:00 UTC from IEEE Xplore. Restrictions apply.
This article has been accepted for publication in a future issue of this journal, but has not been fully edited. Content may change prior to final publication. Citation information: DOI 10.1109/TPWRS.2020.3018869, IEEE
Transactions on Power Systems
V ,
i
*
i
*
strictly satisfies V , while there is an *
z f mn
*
z f mn *
z f mn
*
z f mn *
z f mn *
z f mn (23)
approximate error between the gas system solution *
z f mn
*
z f mn *
z f mn *
z f mn
f *
mn , *
m* ,i* and the precise solution fmn , m* .
Due to the uniqueness of the optimal solution for (15), it
z f z f z f z f z f z f (24)
*
mn
*
mn
*
mn
*
mn
*
mn
*
mn
*
suggests that for any point (e.g., fmn ) whose objective function (21) (18)
*
(e.g., z fmn
) is close enough to the optimal objective value According to (16) and (24), we can deduce that there exists
* *
fmn . Specifically, we can derive
, then this point (e.g.,
the δ(ε), such that fmn
* *
z fmn fmn ) will be close enough to the
At first, the piecewise linear function for the continuous mn i 1 mn
1
function g mn f mn f mn 1 Cmn is stated as
gmni i* i* mn fmn* fmn*
Nmn
N mn
i
hmn f mn gmni , and let the approximate error between mn i 1 mn
i 1
i
Nmn
gmn(fmn) and hmn(fmn) be /2, which will be reduced by increasing gmn mn
mn i 1
the number of segments Nmn [31]-[33].Then, when Nmn>N holds mn
for a given N, there is (27)
Nmn
It can be found that we can choose different values of δ(ε) to
i
1 Cmn gmn
1
g mn f mn hmn f mn f mn i
i 1
2
, *
control the error z f mn *
z f mn
. Intuitively, when 0 ,
f mn f mn
max max
, f mn , (17)
*
z f mn *
z f mn
. In order to guarantee the condition that
Therefore, we have
hmn fmn gmn fmn hmn fmn + , fmn fmn
max max
, fmn (18)
z f z f
*
mn
*
mn , we can choose as
2 2
By adding mn f mn for each part, we can derive (28)
i
Nmn
mn
gmn mn
mn i 1
mn
z fmn z fmn z fmn + , fmn fmn max max
, fmn (19)
2 2 Finally, the proposed LP energy-flow model is written as:
Then, let Θ be the feasible region of the optimization model N mn i
(8). It renders min z g mn i mn f mn (29a)
mn i 1 mn
min z min z min z (20)
Vi ,i , fmn , m ,i 2 Vi ,i , fmn ,m Vi ,i , fmn , m ,i 2 s.t. f mn f nm Gm Dm , m (29b)
mnGF nmGT
Let the optimal gas flow solutions of (8) and (15) be
o const (29c)
V , , f
i
*
i
* *
mn , m* ,i* arg min
Vi ,i , f mn , m ,i
z (21a) N mn
f mn (i )
f mn i , mn (29d)
V i
*
, * *
i , f mn , *
m arg
min z
Vi , i , f mn , m
(21b)
N mn
i 1
i 1
*
z fmn z fmn
2
* *
z fmn
2
(22) n n
PGic PGig PLi GijV j Bij' j , i (29f)
Furthermore, we can derive j 1 j 1
0885-8950 (c) 2020 IEEE. Personal use is permitted, but republication/redistribution requires IEEE permission. See http://www.ieee.org/publications_standards/publications/rights/index.html for more information.
Authorized licensed use limited to: Cornell University Library. Downloaded on August 25,2020 at 17:20:00 UTC from IEEE Xplore. Restrictions apply.
This article has been accepted for publication in a future issue of this journal, but has not been fully edited. Content may change prior to final publication. Citation information: DOI 10.1109/TPWRS.2020.3018869, IEEE
Transactions on Power Systems
n n
c
QGi g
QGi QLi BijV j Gij j , i (29g) TASK I Power System Inputs: TASK II
a) Topology and basic parameters
j 1 j 1
b) Probability distribution of Sample N groups of
Vi const , i (29h) IPGS
electric loads and generators input stochastic
parameters through
i const , i (29i) Inputs
Gas System Inputs: Monte Carlo
a) Topology and basic parameters Simulation.
PGig m Dm , m (29j) b) Probability distribution of gas
loads and gas sources
IV. PROBABILISTIC ENERGY FLOW MODEL
In this section, the proposed energy flow model is extended Power System Outputs:
a) Bus voltage probability distribution TASK III
to a probabilistic energy flow model by considering uncertain b) Branch power flow probability distribution
load and generation characteristics in IPGS, including electric Solve N linear
loads, gas loads, power generator supplies and gas source TASK IV program models
supplies. These items are discussed as follows. (In Parallel)
Gas System Outputs:
1) Electric and Gas Load: Active power and gas loads follow a) Nodal gas pressure probability distribution
normal distributions as in (30a) and (30b) [34], where the b) Pipeline gas flow probability distribution
electric power factor is considered constant.
Fig. 1. Flowchart of IPGS probabilistic energy flow.
1 P 2
f PLi exp Li 2 PLi (30a) In general, Monte Carlo Simulation are widely used in power
2 PLi 2 PLi system analysis, especially in reliability evaluation,
probabilistic power flow and etc., since MCS is quite simple
1 Dm Dm 2 and can provide considerably accurate results, although it needs
f Dm exp (30b) a large number of computations. Fig. 1 depicts the probabilistic
2 Dm 2 Dm
2
energy flow model based on Monte Carlo Simulation by
QLi =PLi tan (30c) randomly sampling N groups of input parameters from the
where PLi and Dm are the expected active electric and gas corresponding probability distribution functions. For each
sample, the corresponding energy flow is calculated using the
loads, respectively, and PLi and Dm are the standard proposed linearized energy flow model. Thus, the probabilistic
deviations of active electric and gas loads, respectively, and energy flow of the IPGS can be determined by solving N linear
is the power factor angle. program models.
2) Generators: The unscheduled generator outages follow the
Binomial distribution [35]-[37]. The power outputs of
V. CASE STUDIES
coal-fired and gas-fired generators are stated as:
In this section, the linear program based energy flow model
, P 0
PGi i Gi
, i (31a) is studied for three IPGSs, i.e., 14-bus-11-node IPGS,
1 i , PGi PGi 39-bus-20-node IPGS, and 118-bus-135-node IPGS. The
algorithm is performed on a workstation with AMD Radeon
i
, QGi 0
QGi
, i (31b) A10-8700P CPU (1.80 GHz) and 8.00 GB RAM using
1 i , QGi QGi
MATLAB and GUROBI 8.0.1. The total number of segments
in the piecewise linearization is set as 100.
where denotes the coal- and gas-fired generators at bus i,
PGi
and QGi are the expected active and reactive power A. Steady Energy Flow of 14-bus-11-node System
The topology of the 14-bus-11-node IPGS is presented in Fig.
outputs of the generator at bus i, respectively, and i is the 2. The power system is a modified IEEE 14-bus system, which
failure rate of the generator at bus i. includes 14 buses, 20 transmission lines, and 5 units [38]. The
3) Gas Source: The output gas flow from the gas source has gas system refers to GASLIB with 11 nodes, 3 gas sources, 2
several states from 0 to Gmmax and the gas supplies of the gas compressors, and 11 pipelines [39]. The gas-fired unit links the
sources are stated as [9]: bus 2 of the power system and node 4 of the gas system, and the
conversion coefficient is 0.005 Mm3/MWd. In the power
m,1 , Gm Gm,1 o
system, B1 is the slack bus whose voltage is 1.06∠0 p.u. In the
m,2 , Gm Gm,2 gas system, N1 is the slack node with the pressure as 60 bar.
Gm (32)
m, , Gm Gm,
where m,i is the probability corresponding to Gm Gm,i
(i 1, 2, , ) and m ,i 1 .
i 1
0885-8950 (c) 2020 IEEE. Personal use is permitted, but republication/redistribution requires IEEE permission. See http://www.ieee.org/publications_standards/publications/rights/index.html for more information.
Authorized licensed use limited to: Cornell University Library. Downloaded on August 25,2020 at 17:20:00 UTC from IEEE Xplore. Restrictions apply.
This article has been accepted for publication in a future issue of this journal, but has not been fully edited. Content may change prior to final publication. Citation information: DOI 10.1109/TPWRS.2020.3018869, IEEE
Transactions on Power Systems
N5 50
N6
N11
B13 B14 B2
1) Steady state energy flow with different gas flow equations: B. Steady Energy Flow in the 39-bus-20-node System
We consider the following three cases for different gas flow Fig. 5 depicts the topology of 39-bus-20-node IPGS. The
equations, where the absolute pressure boost of the power system is a modified IEEE 39-bus system, which
compressors are all set as zero (i.e., 0 bar2). includes 14 buses, 20 transmission lines, 6 coal-fired generators,
Case 1: Pipeline gas flow is modeled using the Weymouth and 4 gas-fired generators [38]. The gas system is a modified
equation. Belgium 20-node natural gas system with 20 nodes, 6 gas
Case 2: Pipeline gas flow is modeled using the Panhandle A sources, 3 compressors, and 23 pipelines [40]. The parameters
equation. of gas-fired generators and compressors are presented in [41],
Case 3: Pipeline gas flow is modeled using the Panhandle B respectively. B31 is the slack bus of the power system with a
o
equation. voltage of 0.982 ∠0 p.u. The lower and upper bounds of
The steady state IPGS energy flow is calculated for the three voltage magnitudes are set as 0.96 p.u. and 1.07 p.u.,
cases using the proposed linear program model. In Fig. 3, gas respectively. In the gas system, N1 is the slack node with a
pressure in Case 1is lower than those in Cases 2 and 3. The pressure of 55 bar. Lower and upper bounds of nodal gas
differences become greater at the nodes that are located farther pressure are set as 25 bar and 70 bar, respectively.
from the slack node, such as N5, N6 and N11. Thus, the G C
B30 B37
proposed gas flow model must consider actual gas system
B25 B26 B28 B29
conditions.
B2
62 B27
B38
B1 B3 B18 B17
Case 1: Weymouth equation C
Case 2: Panhandle A equation
B39 B15 B16
Case 3 :Panhandle B equation B21
58
Nodal pressure (bar)
C B24 B36
B4
B14
C
B5 B12 B13
54 B9 B6 B11
B23
B19
B7 B22
B20
50 B10
B33
B34 B35
B8 B31 B32
C G G C G
46 S
1 26 7 3 4 5 8 9 10 11 S
N5 Electricity load
Node N1 N6
Gas load
Fig. 3. Nodal gas pressures for the three cases. N4 N7
S N2 Gas load of gas-
fied generator
2) Steady Energy flow with different operating conditions of N3
S Bus
compressors: For a high-pressured gas transmission system, S N9
Integrated bus
N14 N12
the Weymouth equation is adopted for illustration. In Fig. 4, the N15 N10 Pipeline
N8 Transmission line
steady IPGS energy flow is solved for different conditions, N17
N11
S Node
including τ0 bar2, τ50 bar2, τ100 bar2, and τ200 bar2. When N16
N13
Integrated node
τ0 bar2, the gas pressures are lower at nodes that are farther N18
Compressor
from the slack node. The pressures at N5, N6 and N11 are much G Gas-fied generator
lower than the pressures at other nodes due to the pressure loss N19
C Coal-fied generator
that occurs during the gas transportation. The nodal gas
S Gas source
N20
Fig. 5. Topology of the 39-bus-20-node IPGS.
0885-8950 (c) 2020 IEEE. Personal use is permitted, but republication/redistribution requires IEEE permission. See http://www.ieee.org/publications_standards/publications/rights/index.html for more information.
Authorized licensed use limited to: Cornell University Library. Downloaded on August 25,2020 at 17:20:00 UTC from IEEE Xplore. Restrictions apply.
This article has been accepted for publication in a future issue of this journal, but has not been fully edited. Content may change prior to final publication. Citation information: DOI 10.1109/TPWRS.2020.3018869, IEEE
Transactions on Power Systems
80
Increase the electric loads by:
Increase the gas loads by: 1.08 0% 135% 137% 160%
70 0% 7% 8% 10%
1.04
50
1.02
40 1
53
30 Feasible 0.98
4 Feasible
0.96
20 Infeasible 0.96
Infeasible
20 0.94 12
10
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 0 3 6 9 12 15
18 21 24 27 30 33 36 39
Node Bus
Fig. 6. Nodal pressure results under different gas load levels. Fig. 7. Bus voltage magnitudes under different electric load levels.
C B1 C B41 C B42 B53 C C C N28 B73 B72 N124 N50 N120 N36
B2 B40 B55
C N26 N25 N125 N39 N121
B117 B33 B39 B54 B56 B59
N57 N123
B3 G N116 N34
B12 B52 B63 N117 B49 N127 N108
B11 B44 B57 B58
C B4 N52
N126 N10 N107 N122 N40
B14 B35 B37
B13 B43
N134 B61 N58
B15 C B60
B34 B48 B50 N53 N33 N44 N61 N46 N109
G B7 B51
N54 N128
G B45 B64 N118 N47 N29
B5 C C B46 N110
B6
B16 B19 B36 B67 N37 N49 N119 N111 N14 N43 N70
C N105
C G N27 N135 N112 N62
B17
B18 B38 B61 S N132
B47 N63 N41 N51 N130 N16 N69 N133
B9 B10
G
B49 G C
C B73 G B90 N113 N7 N64
B20 C B62
G B113 B71 B68 C
N68 N17 N19 N66 N129
B45
B66 N30 N115 B18
G N114 N86
B8 B69 B116
B30 B72 N4 N38 N35 N3 N45
C B65 N131 N15 N32 S
B29 B31
C B21 C C N73
B24 B70 B79 N102
B28 C B32
B22
N21 N23 N48 N56 N94 N91 N12 N67 N85 N22
C B76 B78 B81 G
B118 B99 N6
B115
B26 C C N95
B80 N55 N89 N106 N9 N97 N77 N18 N65 N84 N99
B114 C B74
B25
B27 B23 B106 N13 B19 N90
B25 B75 B77 B97 B104 B105 N103 N71 N8 N79 N72 N20 N1 N92 N2
C B83 C B98 S N100
G C C C S B59 N82 N5 N104 N101 B6
Electricity load B84 B82 B96 N11
B88 B100 N96 N59 N93
Bus B107 Gas load Pipeline S S
C C B89
B95 B103 N60
N31
Integrated bus B93 B94 B108 Node Integrated node N76
Transmission line
B85 C C N88 N24 N78
B109 Gas load of gas-fied generator N98 N87 N74
G Gas-fied generator B86 B90 B92 B8
B102 B110 C C Compressor S Gas source N87 N81 N80
C Coal-fied generator C B101 N42 N75 N83
B111 C
B87 G B91 C B112
Fig. 8. Topology of the 118-bus-135-node IPGS.
Fig. 6 shows the nodal gas pressures for different gas load of the power system with voltage of 1.035∠0 p.u. In the gas
o
levels. When gas load is not larger than 7%, the nodal gas system, N100 is the slack node with a pressure of 60 bar. The
pressures are maintained to be higher than the allowable lower squared pressure boost of each compressor is set as 100 bar2
bound (i.e., 25bar) and the energy flow is feasible. When the (i.e., τ100 bar2). The standard deviations of electric and gas
increased gas load is 8% or more, the energy flow becomes loads are both set as 10% of expected loads, and the failure rate
infeasible. Fig. 7 shows the bus voltages for different electric of each generator is set as 1%. The probabilistic characteristics
load levels, which illustrate that the maximum allowed load of gas supplies are given in [41].
increment is about 136%. When the increased electric load is The sampling time of the Monte-Carlo simulation is set as
higher than the maximum allowable load increment, the bus 5000. Figs. 9 and 10 show the probability distributions of the
voltage of B12 is lower than the allowable lower bound and the bus voltage of B118 and the nodal gas pressure of N5,
energy flow becomes infeasible. respectively. The bus voltage and nodal pressure solved in the
C. Probabilistic Energy Flow in the 118-bus-135-node system steady state are 0.9509 p.u. and 41.18 bar. In Figs. 9 and 10,
both the bus voltage of B118 and the nodal gas pressure of N5
Fig. 8 depicts the topology of 118-bus-135-node IPGS. The fluctuate around their steady-state values. The bus voltage of
power system is a modified IEEE 118-bus system, which
B118 fluctuates between 0.949 p.u. (i.e., 0.2% of the
includes are 118 buses, 186 transmission lines, 42 coal-fired
steady-state voltage) and 0.953 p.u. (i.e., +0.2% of the
generators, and 12 gas-fired generators [38]. The gas system is
steady-state voltage). In the gas system, the pressure fluctuation
referred to as GASLIB with 135 nodes, 6 gas sources, 29
at N5 is much larger, which is 30 bar (i.e., 27.15% of the
compressors, and 141 pipelines [39]. The parameters of
steady-state gas pressure) to 45 bar (i.e., +9.28% of the
gas-fired generators are available in [41]. B69 is the slack bus
0885-8950 (c) 2020 IEEE. Personal use is permitted, but republication/redistribution requires IEEE permission. See http://www.ieee.org/publications_standards/publications/rights/index.html for more information.
Authorized licensed use limited to: Cornell University Library. Downloaded on August 25,2020 at 17:20:00 UTC from IEEE Xplore. Restrictions apply.
This article has been accepted for publication in a future issue of this journal, but has not been fully edited. Content may change prior to final publication. Citation information: DOI 10.1109/TPWRS.2020.3018869, IEEE
Transactions on Power Systems
(p.u.)
steady-state gas pressure). Figs. 11 and 12 show the probability
Cumulative probability
4 CDF
Probability density
B65-B68 and gas flow on the pipeline N11-N31, respectively, 0.8
0.015
1
where power and gas flows fluctuate around their steady-state 2
0.5
values. The gas flow direction does not change during the 0.4 0 0.992
fluctuation, but there is about 20% probability that the active 0 3 4 5
Cumulative probability
Probability density
P min
m m, m
max 0.08 CDF
m m 45
(33) 0.06
min
P Vi Vi Vi
max
i , i 35
0.04
0.5
0.02
where m and i are the thresholds of the violation in bus
25 0 0
voltages and nodal pressures, respectively. 0 2500 5000 25 35 45 55
3
Specifically, the range of the allowable bus voltage is set as Simulation times Gas flow of pipeline 11-31 (1000m /h)
0.95,1.06 p.u. and the range of allowable nodal pressure is set Fig. 12. Probability distribution of the gas flow in pipeline 11-31.
Cumulative probability
0.953
model are reduced with the increasing number of segments.
300 0.6
0.951 When the number of segments is 200, the maximum relative
0.4
200 error of the linearized objective function is 3.11e-04 and that of
0.949 100 0.2 the optimal solutions is smaller than 0.0854.
0.947 0 0 TABLE I COMPUTATIONAL PERFORMANCE ON THREE IPGSS
0 2500 5000 0.948 0.95 0.952 0.954
Simulation times Voltage of bus 118 (p.u.) Times (s)
Fig. 9. Probability distribution of the voltage at bus 118. Test system
20 Seg. 50 Seg. 100 Seg. 200 Seg.
50 14-bus-11-node 0.0096 0.0122 0.0137 0.0185
Gas pressure of node 5(bar)
40 -3
× 10
0.2 3 0.01
TABLE II IMPACT OF THE SEGMENT NUMBERS ON SOLUTION PERFORMANCE
2 0.5
1 Maximum relative
30 0.1 20 Seg. 50 Seg. 100 Seg. 200 Seg.
0 0 error
20 25 30
Piecewise
0 0 0.0364 0.0052 0.0012 3.11e-04
20 linearized function
0 2500 5000 30 35 40 45
Simulation times Gas pressure of node 5(bar) Pipeline gas flow 0.4176 0.2189 0.1333 0.0854
Fig. 10. Probability distribution of the gas pressure at node 5.
VI. CONCLUSIONS
This paper proposed a linearized energy flow model for
IPGSs. The optimal solution of the convex model is
demonstrated to tightly satisfy nonlinear gas flow equations
and linear power flow equations. Furthermore, the proposed
model is extended to the estimation of probabilistic energy
0885-8950 (c) 2020 IEEE. Personal use is permitted, but republication/redistribution requires IEEE permission. See http://www.ieee.org/publications_standards/publications/rights/index.html for more information.
Authorized licensed use limited to: Cornell University Library. Downloaded on August 25,2020 at 17:20:00 UTC from IEEE Xplore. Restrictions apply.
This article has been accepted for publication in a future issue of this journal, but has not been fully edited. Content may change prior to final publication. Citation information: DOI 10.1109/TPWRS.2020.3018869, IEEE
Transactions on Power Systems
flows. Simulation results from three IPGSs show that the [19] J. Qiu, H. Yang, Z. Y. Dong, and et al, "A Linear Programming
Approach to Expansion Co-Planning in Gas and Electricity Markets,"
optimal solution of the proposed linear program model can
IEEE Trans. Power Syst., vol. 31, pp. 3594-3606, 2016.
precisely satisfy the gas flow equations. Moreover, a higher [20] A. Martin, M. Möller and S. Moritz, "Mixed Integer Models for the
solution accuracy can be achieved by increasing the number of Stationary Case of Gas Network Optimization," Math. Prog., vol. 105,
segments by only slightly increasing the computational pp. 563-582, 2006.
[21] M. Antonio, G. Björn and S. Lars, A New Algorithm for MINLP Applied
complexity. Finally, the probabilistic IPGS voltage/pressure
to Gas Transport Energy Cost Minimization, 2013.
security is analyzed which suggests that the fluctuation range of [22] C. Shao, X. Wang, M. Shahidehpour, X. Wang, and B. Wang, "An
the nodal gas pressure is usually larger than that of the bus MILP-Based Optimal Power Flow in Multicarrier Energy Systems,"
voltage. IEEE Trans. Sustain. Energy, vol. 8, pp. 239-248, 2017.
[23] Y. He, M. Shahidehpour, Z. Li, C. Guo, and B. Zhu, "Robust Constrained
Operation of Integrated Electricity-Natural Gas System Considering
REFERENCES Distributed Natural Gas Storage," IEEE Trans. Sustain. Energy, vol. 9,
[1] H. Sun, Q. Guo, B. Zhang, and et al, "Integrated Energy Management pp. 1061-1071, 2018-01-01; 2018-01-01 2018.
System: Concept, Design, and Demonstration in China," IEEE Electrif. [24] C. R. Branan, Rules of thumb for chemical engineers: Gulf Professional
Mag., vol. 6, no. 2, pp. 42-50, 2018 Pub., 2002.
[2] P. Liu, T. Ding, Y. Yang and Z. Zou, "Integrated Demand Response for a [25] P. Janusz, K. Liszka, M. Łaciak, R. Smulski, A. Olìjnik, and O. Susak,
Load Serving Entity in Multi-Energy Market Considering Network "Applicability of equations for pressure losses in transmission gas
Constraints," Appl. Energy, vol. 250, pp. 512-529, 2019. pipelines," AGH Drilling, Oil, Gas, vol. 32, p. 525, 2015.
[3] Q. Zhou, Z. Tian, M. Shahidehpour, X. Liu, A. Abdulwhab, and A. M. [26] T. Ding, Y. Xu, W. Wei, and L. Wu, "Energy Flow Optimization for
Abusorrah, “Optimal consensus-based distributed control strategy for Integrated Power-Gas Generation and Transmission Systems," IEEE
coordinated operation of networked microgrids,” IEEE Trans. Power Trans. on Ind. Informat., p. 1-1, 2019.
Syst., vol. 35, no. 3, pp. 2452-2462, May 2020. [27] J. Yang, N. Zhang, C. Kang, and Q. Xia, "A State-Independent Linear
[4] Q. Zhou, M. Shahidehpour, A. Abdulwhab, and A. M. Abusorrah, Power Flow Model With Accurate Estimation of Voltage Magnitude,"
“Flexible division and unification control strategies in networked IEEE Trans. Power Syst., vol. 32, pp. 3607-3617, 2017.
microgrids for resilience enhancement,” IEEE Trans. Power Syst., vol. [28] T. Ding, Y. Xu, Y. Yang, Z. Li, X. Zhang, and F. Blaabjerg, "A Tight
35, no. 1, pp. 474-486, Jan. 2020. Linear Program for Feasibility Check and Solutions to Natural Gas Flow
[5] R. Lu, T. Ding, B. Qin, J. Ma, X. Fang, and Z. Y. Dong, "Multi-Stage Equations," IEEE Trans. Power Syst., vol. 34, pp. 2441-2444, 2019.
Stochastic Programming to Joint Economic Dispatch for Energy and [29] C. Correa-Posada and P. Sánchez-Martín, “Integrated Power and Natural
Reserve with Uncertain Renewable Energy," IEEE Trans. Sustain. Gas Model for Energy Adequacy in Short-Term Operation,” IEEE Trans.
Energy, Early Access, 2019. Power Syst., vol. 30, no. 6, pp. 3347-3355, 2014.
[6] Y. Xu, T. Ding, M. Qu, P. Du, "Adaptive Dynamic Programming Based [30] N. Keyaerts, “Gas balancing and line-pack flexibility. concepts and
Gas-Power Network Constrained Unit Commitment to Accommodate methodologies for organizing and regulating gas balancing in liberalized
Renewable Energy with Combined-Cycle Units", IEEE Trans. on and integrated EU gas markets,” Open Access Publications From
Sustain. Energy, Early Access, 2019. Katholieke Universiteit Leuven, Katholieke Universiteit Leuven, 2012.
[7] B. Zhao, A. J. Conejo and R. Sioshansi, "Coordinated Expansion [31] T. Li and M. Shahidehpour, “Price-based unit commitment: A case of
Planning of Natural Gas and Electric Power Systems," IEEE Trans. Lagrangian relaxation versus mixed integer programming,” IEEE Trans.
Power Syst., vol. 33, pp. 3064-3075, 2018. Power Syst., vol. 20, no. 4, pp. 2015–2025, Nov. 2005.
[8] Y. Hu, Z. Bie, T. Ding, and Y. Lin, "An NSGA-II based multi-objective [32] M. Lin, G. Carlsson, D. Ge and et al, “A Review of Piecewise
optimization for combined gas and electricity network expansion Linearization Methods,” Math. Problems in Eng., vol. 2013, 2013, Art.
planning," Appl. Energy, vol. 167, pp. 280-293, 2016. no. 101376.
[9] Z. Zeng, T. Ding, Y. Xu, Y. Yang, and Z. Dong, "Reliability Evaluation [33] R. V. Robert, “Linear programming: Foundations and extensions,”
for Integrated Power-Gas Systems with Power-to-Gas and Gas Princeton University, Princeton, NJ 08544, 1996.
Storages," IEEE Trans. Power Syst., vpl. 35, no. 1, pp. 571 - 583, 2020. [34] H. Khorsand and A. R. Seif, "Probabilistic energy flow for multi-carrier
[10] T. Ding, Y. Hu and Z. Bie, "Multi-Stage Stochastic Programming with energy systems," Renewable and Sustainable Energy Reviews, vol. 94,
Nonanticipativity Constraints for Expansion of Combined Power and pp. 989-997, 2018.
Natural Gas Systems," IEEE Trans. Power Syst., vol. 33, pp. 317-328, [35] J. Morales and J. Pérez-Ruiz, “Point Estimate Schemes to Solve the
2018. Probabilistic Power Flow,” IEEE Trans. Power Syst., vol. 22, no. 4, pp.
[11] X. Zhang, L. Che, M. Shahidehpour, A. S. Alabdulwahab, and A. 1594–1601, Nov. 2007.
Abusorrah, "Reliability-Based Optimal Planning of Electricity and [36] H. Zang, L. Cheng, T. Ding, K. W. Cheung, M. Wang, Z. Wei, G. Sun, "
Natural Gas Interconnections for Multiple Energy Hubs," IEEE Trans. Estimation and validation of daily global solar radiation by day of the
Smart Grid, vol. 8, pp. 1658-1667, 2017. year-based models for different climates in China," Renewable energy,
[12] C. M. Correa-Posada and P. Sánchez-Martın, "Security-Constrained vol. 135, pp. 984-1003, 2019.
Optimal Power and Natural-Gas Flow," IEEE Trans. Power Syst., vol. 29, [37] C. Yan, T. Ding, Z. Bie and X. Wang, “A Geometric Programming to
pp. 1780-1787, 2014-01-01; 2014-01-01 2014. Importance Sampling for Power System Reliability Evaluation,” IEEE
[13] C. M. Correa-Posada and P. Sánchez-Martín, "Security-constrained unit Trans. Power Syst., vol. 32, no. 2, pp. 1568–1569, Mar. 2017.
commitment with dynamic gas constraints," in 2015 IEEE Power & [38] R. D. Zimmerman, C. E. Murillo-Sa ́ nchez and R. J. Thomas,
Energy Society General Meeting, Denver, CO, USA, 2015, pp. 1-5. "MATPOWER: Steady-State Operations, Planning, and Analysis Tools
[14] H. Khani, N. El-Taweel and H. E. Z. Farag, "Power Loss Alleviation in for Power Systems Research and Education," IEEE Trans. Power Syst.,
Integrated Power and Natural Gas Distribution Grids," IEEE vol. 26, pp. 12-19, 2011.
Transactions on Industrial Informatics, p. 1-1, 2019. [39] M. Schmidt, D. Aßmann, R. Burlacu, and et al, "GasLib—A Library of
[15] D. De Wolf and Y. Smeers, "The Gas Transmission Problem Solved by Gas Network Instances," Data, vol. 2, p. 40, 2017.
an Extension of the Simplex Algorithm," Manag. Sci., vol. 46, pp. [40] T. Ding, Y. Xu, W. Wei and L. Wu, "Optimal Energy Flow for Integrated
1454-1465, 2000. Power-Gas Generation and Transmission Systems," IEEE Trans. Ind.
[16] A. A. More, "Analytical solutions for the Colebrook and White equation Inform., vol. 16, no. 3, pp. 1677 - 1687, 2020.
and for pressure drop in ideal gas flow in pipes," Chemical Engineering [41] https://www.researchgate.net/profile/Tao_Ding7--Data
Science, vol. 61, pp. 5515-5519, 2006.
[17] C. Liu, M. Shahidehpour, Y. Fu, and Z. Li, "Security-Constrained Unit
Commitment With Natural Gas Transmission Constraints," IEEE Trans.
Power Syst., vol. 24, pp. 1523-1536, 2009. Weihao Jia (S’20) received the B.S. degree from the School of Electrical
[18] S. An, Q. Li and T. W. Gedra, "Natural Gas and Electricity Optimal Engineering, Xi’an Jiaotong University, Xi’an, China, in 2020. He is currently
Power Flow," in Transmission and Distribution Conference and working toward the M.S. degree at Xi'an Jiaotong University. His major
Exposition, Dallas, USA, pp. 138 - 143, 2003. research interests include power system optimization and renewable energy
0885-8950 (c) 2020 IEEE. Personal use is permitted, but republication/redistribution requires IEEE permission. See http://www.ieee.org/publications_standards/publications/rights/index.html for more information.
Authorized licensed use limited to: Cornell University Library. Downloaded on August 25,2020 at 17:20:00 UTC from IEEE Xplore. Restrictions apply.
This article has been accepted for publication in a future issue of this journal, but has not been fully edited. Content may change prior to final publication. Citation information: DOI 10.1109/TPWRS.2020.3018869, IEEE
Transactions on Power Systems
10
Zekai Wang (S’20) received the B.S. degree from the School of Electrical
Engineering, Xi’an Jiaotong University, Xi’an, China, in 2018. He is currently
working toward the M.S. degree at Xi'an Jiaotong University. His major
research interests include power system optimization and resilience.
Quan Zhou (SM’19) received the B.S. and M.S. degrees from the Department
of Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China, in
2011 and 2016, respectively. He received the Ph.D. degree from Illinois
Institute of Technology, Chicago, IL, USA, in 2019. He is currently a Senior
Research Associate in the Robert W. Galvin Center for Electricity Innovation at
Illinois Institute of Technology. His research interests include microgrid
operation and control, cyber-physical systems, 5G wireless communications,
smart cities, and energy economics.
0885-8950 (c) 2020 IEEE. Personal use is permitted, but republication/redistribution requires IEEE permission. See http://www.ieee.org/publications_standards/publications/rights/index.html for more information.
Authorized licensed use limited to: Cornell University Library. Downloaded on August 25,2020 at 17:20:00 UTC from IEEE Xplore. Restrictions apply.