29/07/2019 the requested s data is not available.

the plnsol command is ignored

We use cookies to personalize content and ads, provide social media features and analyze site traffic, and we may share this data with our partners, as outlined by
our Cookie Policy. You may change your cookie preferences at any time using the Cookie Preference Center. Cookie Policy (https://www.ansys.com/footer/cookie- ❯ Cookie Settings ✓ Accept All Cookies
policy)

Home (/) Leaderboard (/home/leaderboard/) Activity (/home/activity/)

Badges (/badge/allbadges/)

(https://goo.gl/2R7RY3)

(/members/register/)

(https://www.ansys.com/en-in/academic/student-teams)
Physics Simulation (/cat/your-favorite-physics-1/) /  Structural Mechanics (/cat/structural-mechanics/)
/  the requested s data is not available. the plnsol command is ignored

the requested s data is not available. the plnsol command is


ignored
 937 Views  Last Post 21 June 2019

Serdal (/pro le/serdal/) posted this 14 May 2019

hi all
(/pro le/serdal/)
I am taking the error in my ANSYS 2019 R1. After the axial loading to my volume, I want to
display the stress, strain results but I take warning which is 'The requested S data is not
avaliable. The PLNSOL command is ignored'. Then, if I go to folder which is saved of Ansys
les, I observe err folder. The err folder contains messages which are ' The EPLOT command
cannot be executed.  The selected elements cannot be displayed by PowerGraphics.  To
correct this situation, select di erent elements or turn o PowerGraphics.' Then I
shut PowerGraphics but the result is still same My ansys programme is Student version from
https://studentcommunity.ansys.com/thread/the-requested-s-data-is-not-available-the-plnsol-command-is-ignored/ 1/6
29/07/2019 the requested s data is not available. the plnsol command is ignored
shut PowerGraphics but the result is still same. My ansys programme is Student version from
Ansys products. By the way my shape is created in Ansys Mechanical apdl-2015, I want to
load in my Ansys-2019 to this volume but it is not. I hope I could explain my situation

Thanks for any help 

Serdal     

#Permalink (/thread/the-requested-s-data-is-not-available-the-plnsol-command-is-ignored/?order=all#comment-
56df0a9e-8a06-4057-a0bb-aa4d013f84b9)
0 0 0

MECHANICAL-APDL (/TAGGED/MECHANICAL-APDL/) ANSYS-2019-R1 (/TAGGED/ANSYS-2019-R1/)

STRESS-STRAIN-CONTOUR (/TAGGED/STRESS-STRAIN-CONTOUR/)

6 Comments
Order By: Standard (/thread/the-requested-s-data-is-not-available-the-plnsol-command-is-ignored/) | Newest
(?order=Newest) | Votes (?order=Votes)

SandeepMedikonda (/pro le/smedikon/) posted this 15 May 2019

Are you reading in the rst le in 2019R1 MAPDL?


(/pro le/smedikon/)
ANSYS looks like the elements you selected are not valid/present?

Are you able to plot the total deformation for the whole structure?

#Permalink (/thread/the-requested-s-data-is-not-available-the-plnsol-command-is-ignored/?order=all#comment-
60ef3f9f-ed72-4225-9884-aa4e001d1f54)
0 0 0

preran (/pro le/preran/) posted this 15 May 2019

Not able to get the stress solution and de ne element table. In stress solution it shows the
(/pro le/preran/)
requested S data is not available. The PRNSOL command is ignored. and in element table
while adding SMISC, # it shows the requested database is not available. The ETABLE
command is ignored. this is in the student version ANSYS 2019 R1.

#Permalink (/thread/the-requested-s-data-is-not-available-the-plnsol-command-is-ignored/?order=all#comment-
acb95c62-fca3-4da5-ab48-aa4e004a6cc5)
0 0 0

sk_cheah (/pro le/sk_cheah/) posted this 15 May 2019

Not sure what element you are using. Perhaps try OUTRES, ALL, ALL 
(/pro le/sk_cheah/)
(https://www.sharcnet.ca/Software/Ansys/16.2.3/en-
us/help/ans_cmd/Hlp_C_OUTRES.html)before the solution.

Kind regards,
Jason

#Permalink (/thread/the-requested-s-data-is-not-available-the-plnsol-command-is-ignored/?order=all#comment-
5ac8cef1-47dc-4b1d-bb40-aa4e014962ea)
1 0 0

https://studentcommunity.ansys.com/thread/the-requested-s-data-is-not-available-the-plnsol-command-is-ignored/ 2/6
29/07/2019 the requested s data is not available. the plnsol command is ignored
Liked by (/pro le/serdal/)

Serdal (/pro le/serdal/) posted this 15 May 2019

Hi jason,

I used solid65, solid45 and link180 for my reinforced concrete shape. I am new in Ansys, I
(/pro le/serdal/)
don't know what ı must do. What is outres, Where is it, I am very appreciate for your helping

best regards

Serdal

#Permalink (/thread/the-requested-s-data-is-not-available-the-plnsol-command-is-ignored/?order=all#comment-
492b7dee-afa0-400b-8b80-aa4e014c1127)
0 0 0

SandeepMedikonda (/pro le/smedikon/) posted this 16 May 2019

Click on the Results Viewer and load the RST, this should have the total deformation at least
(/pro le/smedikon/)
by default
ANSYS

If that doesn't work, try using OUTRES,ALL,ALL as jason suggested in the command window.

Take some time to go over the most commonly used commands in APDL. This article
(http://www.padtinc.com/blog/the-focus/20-apdl-commands-every-ansys-mechanical-user-
should-know) is very useful in getting started.

https://studentcommunity.ansys.com/thread/the-requested-s-data-is-not-available-the-plnsol-command-is-ignored/ 3/6
29/07/2019 the requested s data is not available. the plnsol command is ignored

Additionally, the Cornell learning modules


(https://con uence.cornell.edu/display/SIMULATION/ANSYS+Learning+Modules) have a few
tutorials that you can pick up easily from.

Regards,
Sandeep

#Permalink (/thread/the-requested-s-data-is-not-available-the-plnsol-command-is-ignored/?order=all#comment-
30b8ed63-fcb3-49be-9040-aa4f0010d340)
0 0 0

nsiwac (/pro le/nsiwac/) posted this 21 June 2019 - Last edited 21 June 2019

Hey Serdal,
(/pro le/nsiwac/)
Pomalley had the same issue and he suggested changing these settings.

I was having the same issue but changing the mechanical product launcher settings from
distributed computing to shared memory seems to work.  

#Permalink (/thread/the-requested-s-data-is-not-available-the-plnsol-command-is-ignored/?order=all#comment-
d3a8d8d7-3839-48bf-9d02-aa730179b237)
0 0 0

SEARCH CHANGE LANGUAGE

Search for... English (United Kingdom)

CATEGORIES
Search in...
All Categories (/category/)
Select Category Community Rules, Guidelines, and Tips
(/cat/community-rules-guideline-and-tips/)
Go News & Announcements (/cat/news-
announcements/)
Student Products (/cat/student-products/)
https://studentcommunity.ansys.com/thread/the-requested-s-data-is-not-available-the-plnsol-command-is-ignored/ 4/6
29/07/2019 the requested s data is not available. the plnsol command is ignored

Pre and Post Processing (/cat/pre-and-post-


processing-1/)
Geometry and CAD (/cat/geometry-and-cad-1/)
Mesh Generation (/cat/mesh-generation-1/)

Result Visualisation (/cat/results-and-visualisation-1/)


Physics Simulation (/cat/your-favorite-physics-1/)
Thermodynamics (/cat/thermodynamics/)
Structural Mechanics (/cat/structural-mechanics/)
Fluid Dynamics (/cat/ uid-dynamics-1/)
Electromagnetics (/cat/electromagnetics-1/)
Embedded Software (/cat/embedded-software/)
Multiphysics (/cat/multiphysics-1/)
Systems (/cat/systems/)
Tutorials, Articles and Textbooks (/cat/support-
resources-tutorials/)
ANSYS AIM Tutorials (/cat/ansys-aim-tutorials/)
ANSYS Formula SAE/BAJA SAE Tutorials (/cat/ansys-
formula-sae-baja-sae-tutorials/)
ANSYS SpaceClaim Tutorials (/cat/ansys-spaceclaim/)
Textbooks (/cat/textbooks/)
ANSYS Discovery Live Tutorials (/cat/ansys-discovery-
tutorials/)
Installation and Licensing (/cat/installation-and-
licensing/)
Student Competition Teams (/cat/student-
competition-teams/)
eMasters Degree from UPM (/cat/emasters-degree-
from-upm/)
Jobs (/cat/jobs/)
Site Feedback (/cat/site-feedback-help/)

POPULAR TAGS THIS WEEKS HIGH EARNERS

FLUENT 602 (/TAGGED/FLUENT/) abenhadj (/pro le/abenhadj/) 17 


FLUID-DYNAMICS 202 (/TAGGED/FLUID-DYNAMICS/)
peteroznewman (/pro le/peteroznewman/) 11 
UDF 201 (/TAGGED/UDF/) ANSYS 175 (/TAGGED/ANSYS/)
Shalee (/pro le/shalee/) 9
CFD 165 (/TAGGED/CFD/)
Johns (/pro le/johns-7/) 9
WORKBENCH 163 (/TAGGED/WORKBENCH/)
rwoolhou (/pro le/rwoolhou/) 9
ASC 154 (/TAGGED/ASC/)

STRUCTURAL-MECHANICS 137 (/TAGGED/STRUCTURAL-MECHANICS/)


DiegoBarini (/pro le/diegobarini/) 6

MECHANICAL 133 (/TAGGED/MECHANICAL/) rkgupta369 (/pro le/rkgupta369/) 6


ERROR 131 (/TAGGED/ERROR/) MESH 131 (/TAGGED/MESH/) Kremella (/pro le/kremella/) 5
APDL 115 (/TAGGED/APDL/) CFX 114 (/TAGGED/CFX/) tmg11 (/pro le/tmg11/) 3
GENERAL 111 (/TAGGED/GENERAL/)
jj77 (/pro le/jj77/) 3
MESHING 99 (/TAGGED/MESHING/)

MAXWELL 89 (/TAGGED/MAXWELL/) HFSS 83 (/TAGGED/HFSS/) RECENT ACTIVITY

STUDENT 73 (/TAGGED/STUDENT/)
mecheuzgec (/pro le/mecheuzgec/) is a new member
STATIC-STRUCTURAL 70 (/TAGGED/STATIC-STRUCTURAL/)
in the forum
https://studentcommunity.ansys.com/thread/the-requested-s-data-is-not-available-the-plnsol-command-is-ignored/ 5/6
29/07/2019 the requested s data is not available. the plnsol command is ignored
SPACECLAIM 63 (/TAGGED/SPACECLAIM/)
charlie164 (/pro le/charlie164/) is a new member in
the forum
Davidperlin (/pro le/davidperlin/) is a new member in
the forum
mdgodsave (/pro le/mdgodsave/) is a new member in
the forum
rkgupta369 (/pro le/rkgupta369/) has been awarded
the You've Given Your First Vote Up badge

Latest Members: Members Currently Online:

(/pro le/mecheuzgec/) (/pro le/charlie164/) (/pro le/chanakatub/) (/pro le/ghost3507/)


(/pro le/davidperlin/) (/pro le/mdgodsave/) (/pro le/georgiro1/) (/pro le/vinitraj3/)
(/pro le/quangthanh94/) (/pro le/ganu-1/) (/pro le/many-10/) (/pro le/alpine/)
(/pro le/kkooykcc/) (/pro le/jayashree/) (/pro le/quangthanh94/) (/pro le/mecheuzgec/)
(/pro le/azim07/) (/pro le/aamir/)

Terms and Conditions (/terms.html) Privacy Policy (http://www.ansys.com/footer/privacy-policy)

Export Control Compliance (http://www.ansys.com/footer/export-control-compliance)

Legal Notices (http://www.ansys.com/footer/legal-notices)

(https://www.youtube.com/user/ANSYSHowToVideos) (http://www.facebook.com/ANSYSInc)
(http://www.twitter.com/ansys) (http://www.linkedin.com/company/ansys-inc)
(https://plus.google.com/u/1/+ansys)

https://studentcommunity.ansys.com/thread/the-requested-s-data-is-not-available-the-plnsol-command-is-ignored/ 6/6

You might also like