Calculo Venteo API 2000
Based on API 2000 5th Edition April 1998 Fluid Lean Amine
Normal Boiling point < 148,9 ºC or Flash point < 37,8 ºC? Yes
a= 9,5 º a Insulation
Volumen Shell No
3
Vol Roof = 37,9 m Roof No
Vol Shell = 1018 m3
Vol Total = 1056 m3 9,0 m
Surface
Sup Roof = 114,7 m2
Sup Shell = 339,3 m2
Sup Total = 454 m2
12,0 m
Atmospheric Pressue Variation No Design pressure
PATM = 1,013 bar Vacuum -0,005 bar g
DP = 0 bar/h Pressure 0,025 bar g
INTERCONNECTION - IN
Dp available =
2
48 m <> 4,9 kg/cm
2 84,7 1000 0,88 STD 2,067 1,1 106,88 35,7 10,87 6,5E+05 4,9E-03 0,000871
INTERCONNECTION - OUT
Dp available =
2
48 m <> 4,9 kg/cm
2 84,7 1000 0,88 STD 2,067 1,1 106,88 35,7 10,87 6,5E+05 4,9E-03 0,000871
DRAIN
2 118,6 1000 0,88 std 2,067 1,1 207,85 49,9 15,22 9,1E+05 4,8E-03 0,000871