Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

LIGITEK ELECTRONICS CO.,LTD.

Property of Ligitek Only

LED ARRAY
Pb
Lead-Free Parts

LA16B/DBK-S19-PF

DATA SHEET

DOC. NO : QW0905-LA16B/DBK-S19-PF

REV. : A

DATE : 10 - Mar. - 2007


LIGITEK ELECTRONICS CO.,LTD.
Property of Ligitek Only

PART NO. LA16B/DBK-S19-PF Page 1/5

Package Dimensions

4.6 2.4±0.5 6.5

Ø 3.5

3.0
7.4
5.08

3.5±0.5
□0.5
TYP

2.54TYP 4.75± 0.5


+ -

LDBK2341
3.0

5.0

1.5MAX

25.0MIN

□0.5
TYP
1.0MIN

2.54TYP
+ -
Note : 1.All dimension are in millimeter tolerance is ±0.25mm unless otherwise noted.
2.Specifications are subject to change without notice.
LIGITEK ELECTRONICS CO.,LTD.
Property of Ligitek Only

PART NO. LA16B/DBK-S19-PF Page 2/5

Absolute Maximum Ratings at Ta=25 ℃

Ratings
Parameter Symbol UNIT
DBK

Forward Current IF 30 mA
Peak Forward Current
IFP 100 mA
Duty 1/10@10KHz
Power Dissipation PD 120 mW

Reverse Current @5V Ir 50 μA

Electrostatic Discharge( * ) ESD 150 V

Operating Temperature Topr -20 ~ +80 ℃

Storage Temperature Tstg -30 ~ +100 ℃

* glove
Static Electricity or power surge will damage the LED. Use of a conductive wrist band or anti-electrosatic
is recommended when handing these LED. All devices, equipment and machinery must be properly
grounded.

Typical Electrical & Optical Characteristics (Ta=25 ℃)

Dominant Spectral Forward Luminous Viewing


wave halfwidth voltage intensity angle
COLOR
PART NO MATERIAL length △λ nm @20mA(V) @20mA(mcd) 2 θ 1/2
λD nm (deg)
Emitted Lens Typ. Max. Min. Typ.

LA16B/DBK-S19-PF InGaN/GaN Blue Blue Transparent 470 30 3.5 4.0 550 1100 30

Note : 1.The forward voltage data did not including ±0.1V testing tolerance.
2. The luminous intensity data did not including ±15% testing tolerance.
LIGITEK ELECTRONICS CO.,LTD.
Property of Ligitek Only

PART NO. LA16B/DBK-S19-PF Page 3/5

Typical Electro-Optical Characteristics Curve


DBK CHIP

Fig.1 Forward current vs. Forward Voltage Fig.2 Relative Intensity vs. Forward Current

1000 3.0
Forward Current(mA)

2.5

Normalize @20mA
Relative Intensity
100
2.0

10 1.5

1.0
1
0.5

01 0.0
1.0 2.0 3.0 4.0 5.0 1 10 100 1000

Forward Voltage(V) Forward Current(mA)

Fig.3 Forward Voltage vs. Temperature Fig.4 Relative Intensity vs. Temperature

1.2 3.0
Forward Voltage@20mA

Relative Intensity@20mA

2.5
Normalize @25℃

Normalize @25℃

1.1
2.0

1.0 1.5

1.0
0.9
0.5

0.8 0.0
-40 -20 0 20 40 60 80 100 -40 -20 0 20 40 60 80 100

Ambient Temperature( ℃) Ambient Temperature( ℃)

Fig.5 Relative Intensity vs. Wavelength

1.0
Relative Intensity@20mA

0.5

0.0
400 450 500 550

Wavelength (nm)
LIGITEK ELECTRONICS CO.,LTD.
Property of Ligitek Only

PART NO. LA16B/DBK-S19-PF Page 4/5

Soldering Condition(Pb-Free)

1.Iron:
Soldering Iron:30W Max
Temperature 350 °C Max
Soldering Time:3 Seconds Max(One time only)
Distance:2mm Min(From solder joint to case)

2.Wave Soldering Profile


Dip Soldering
Preheat: 120° C Max
Preheat time: 60seconds Max
Ramp-up
2°C/sec(max)
Ramp-Down:-5°C/sec(max)
Solder Bath:260° C Max
Dipping Time:3 seconds Max
Distance:2mm Min(From solder joint to case)

Temp(° C)

260° C3sec Max


260°
5° /sec
max

120°

2° /sec
25° max
0° 0
50 100 150
Preheat
Time(sec)
60 Seconds Max

Note: 1.Wave solder should not be made more than one time.
2.You can just only select one of the soldering conditions as above.
LIGITEK ELECTRONICS CO.,LTD.
Property of Ligitek Only

PART NO. LA16B/DBK-S19-PF Page 5/5

Reliability Test:

Reference
Test Item Test Condition Description
Standard

1.Under Room Temperature This test is conducted for the purpose MIL-STD-750: 1026
Operating Life Test 2.If=20mA of detemining the resistance of a part MIL-STD-883: 1005
3.t=1000 hrs (-24hrs, +72hrs) in electrical and themal stressed. JIS C 7021: B-1

The purpose of this is the resistance of


High Temperature 1.Ta=105 ℃±5 ℃ the device which is laid under condition MIL-STD-883:1008
Storage Test 2.t=1000 hrs (-24hrs, +72hrs) of high temperature for hours. JIS C 7021: B-10

The purpose of this is the resistance


Low Temperature 1.Ta=-40 ℃±5℃ of the device which is laid under
Storage Test 2.t=1000 hrs (-24hrs, +72hrs) JIS C 7021: B-12
condition of low temperature for hours.

High Temperature 1.Ta=65 ℃±5℃


The purpose of this test is the resistance MIL-STD-202:103B
High Humidity Test 2.RH=90 %~95 %
of the device under tropical for hours. JIS C 7021: B-11
3.t=240hrs ±2hrs

1.Ta=105 ℃±5 ℃&-40 ℃±5℃ The purpose of this is the resistance of MIL-STD-202: 107D
Thermal Shock Test (10min) (10min) the device to sudden extreme changes MIL-STD-750: 1051
2.total 10 cycles in high and low temperature. MIL-STD-883: 1011

This test intended to determine the


thermal characteristic resistance MIL-STD-202: 210A
Solder Resistance 1.T.Sol=260 ℃±5℃
of the device to sudden exposures MIL-STD-750: 2031
Test 2.Dwell time= 10 ±1sec. at extreme changes in temperature JIS C 7021: A-1
when soldering the lead wire.

MIL-STD-202: 208D
1.T.Sol=230 ℃±5℃ This test intended to see soldering well MIL-STD-750: 2026
Solderability Test
2.Dwell time=5 ±1sec performed or not. MIL-STD-883: 2003
JIS C 7021: A-2