Professional Documents
Culture Documents
1029 Series Fuel Energy Cold AIR Baffle Burner: Capabilities
1029 Series Fuel Energy Cold AIR Baffle Burner: Capabilities
1029 Series Fuel Energy Cold AIR Baffle Burner: Capabilities
CAPABILITIES
Luminous flames at all firing levels
High release rates with moderate air pressure
Turndown to 15 to 1 on ratio with flame
characteristics and direction maintained
with gas
Stable flames with lengths tailored to the
application
FEATURES APPLICATIONS
Luminous, well directed flame Aluminum and Copper Reverberatory
Furnaces
Rugged fabricated construction
Many other Applications requiring
Refractory baffle flame stabilization luminous, high momentum flames at all
Baffle shields the burner internals from firing levels.
flame
Suitable for operation at furnace BURNER IGNITION
temperatures up to 2600°F (1427°C)
Heat resistant alloy nozzle Pilot
OPTIONS
Designs with cleanout doors Angled air riser
Angled mounting flange
CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are
urged to comply with National Safety Standards and/or Insurance Underwriters recommendations
NOTE: GENERAL DIMENSION INFORMATION. SEE BLOOM REPRESENTATIVE FOR CERTIFIED DIMENSIONS FOR CONSTRUCTION
CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are
urged to comply with National Safety Standards and/or Insurance Underwriters recommendations
Ship
Catalog General Dimensions*(inches/mm) Weight
No. less
1029- block
A B C D E G H K M N O P R S T AA AB lbs kg
4 4.38 10.75 7.75 14 5.5 .88 10.75 5.94 .63 6.69 8 15.13 .38 .50
040 100 45
102 111 273 197 356 140 22 273 151 16 170 203 384 10 13
SEE GAS LINE SIZE CHART
6 5.38 11.50 8.75 16 6 .88 12.75 7.88 .63 8.69 8 16.88 .38 .50
TO SUIT APPLICATION
060 140 64
152 137 292 222 406 152 22 324 200 16 221 203 429 10 13
6 5.38 11.50 9.38 18 7 1.13 14 7.88 .63 8.69 8 16.88 .38 .50
06X 190 86
152 137 292 238 457 178 29 356 200 16 221 203 429 10 13
8 6.38 12.50 10.38 20 8 1.13 16 10 .63 10.81 8 18.88 .38 .50
080 275 125
203 162 318 264 508 203 29 406 254 16 275 203 480 10 13
8 6.38 12.50 10.38 20 8 1.13 16 10 .63 10.19 8 18.88 .38 .50
08X 275 125
203 162 318 264 508 203 29 406 254 16 259 203 480 10 13
10 7.38 15 11.50 22 9 1.13 18 12.25 .75 14.06 12 22.38 .38 .50
100 380 172
254 187 381 292 559 229 29 457 311 19 357 305 568 10 13
*Other combinations of air connection (“A”) and body (“M”) diameters available to suite specific applications.
NOTE: GENERAL DIMENSION INFORMATION. SEE BLOOM REPRESENTATIVE FOR CERTIFIED DIMENSIONS FOR CONSTRUCTION
CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are
urged to comply with National Safety Standards and/or Insurance Underwriters recommendations
Ship
Catalog General Dimensions* (inches/mm) Weight
No. less block
1029-
A B C D E G H K M N O P R S T AA AB lbs kg
12 8.38 17 12.50 24 10 1.13 20 14.25 .75 16.06 12 25.38 .50 .50
120 440 200
305 213 432 318 610 254 29 508 362 19 408 305 645 13 13
14 9.38 18 13.50 26 11 1.13 22 16.25 .75 18.06 12 27.38 .50 .50
140 500 227
SEE GAS LINE SIZE CHART
356 238 457 343 660 279 29 559 413 19 459 305 695 13 13
TO SUIT APPLICATION
*Other combinations of air connection (“A”) and body (“M”) diameters available to suite specific applications.
NOTE: GENERAL DIMENSION INFORMATION. SEE BLOOM REPRESENTATIVE FOR CERTIFIED DIMENSIONS FOR CONSTRUCTION
CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are
urged to comply with National Safety Standards and/or Insurance Underwriters recommendations.