DESIGN DATA
CALCULATED LIFE TIME OF ANODE (Y) = 25 Years
CURRENT DENSITY IN SEAWATER (CDSW) = 35 mA/sq.m
CURRENT DENSITY IN SEABED (CDSB) = 15 mA/sq.m
CONSUMPTION RATE OF ALUMUNIUM WATER FACE (CON) = 3.5 Kg/Amp.Y
ANODE UTILIZATION FACTOR (U) = 0.9