TECHNICAL INFO EXPRESS

MACHINE : DKS & SYSTEM 88


Date : 26/06/01. SAV IET N°09 V02 ed 02 Page : 1/3
SUMMARY: TFT reset
Application on : Application mode :
All machines Immediately :
If pb appears If necessary : ç
Periodically :
Next service call :

If when making morning calibration or print you are getting wrong colours, density,
definition. You are probably having a bad rest of the TFT PCB by the PCIHR PCB.
This problem can happened during machine switch on if the PC is on faster than the
TFT PCB. The reset signal is send but the TFT PCB cannot accept it.

To solve this Problem you must add a dongle on the TFT PCB. It will simulate the
reset information 5 seconds later.

It must be installed as per the following pictures.


When doing this operation your arm must be connected to ground to avoid damage
to the LCD booster.

Dongle

THESE INFORMATIONS ARE DESIGNED ONLY FOR TECHNICIANS AND ARE CONFIDENTIAL, AND NOT CONTRACTUAL.
TECHNICAL INFO EXPRESS
MACHINE : DKS & SYSTEM 88
Date : 26/06/00 SAV IET N°09 V02 ed 02 Page : 2/3

Connection on TFT PCB (Ref. 995 000 080x)

Power connection on the board 995 000 080x

THESE INFORMATIONS ARE DESIGNED ONLY FOR TECHNICIANS AND ARE CONFIDENTIAL, AND NOT CONTRACTUAL.
TECHNICAL INFO EXPRESS
MACHINE : DKS & SYSTEM 88
Date : 26/06/00 SAV IET N°09 V02 ed 02 Page : 3/3

Connection on TFT PCB (Ref. 995 000 071x)