Magnum IEC Air Circuit Breakers Effective May 2003
Prices subject to change without notice.
Price List Refer to SP 25-000X
(All prices in US$ for export sale) Dated March 1, 2002
The Magnum utilizes a true two-step stored energy mechanism for The Digitrip RMS 1150 provides programmability for more
manually and electrically operated breakers. The potential energy sophisticated distribution systems. It incorporates systems
is stored in the mechanism to close the breaker in 5 cycles or less. monitoring information including power factor, voltage, current,
Sufficient energy to open the breaker remains available following harmonic distortion values, and waveform capture with a three
the closing operation. line (eight character) LED display. In addition, this trip unit has two
programmable contacts, time stamping of trip events, 1%
After closing, the charging spring can be recharged to provide accuracy on metered values and 2% on energy and power,
potential energy for reclosing following a fault, providing high systems diagnostics and IMPACC/PowerNet communications.
continuity of service. This feature allows for the following
sequence: charge-close-recharge-open-close-open. A common family of accessories are available to fit all breaker
frame sizes. Magnum through-the-window accessories are
On manually operated breakers, closing springs are charged by installed near the right front of the breaker. The unique windows in
hand. For electrically operated breakers, springs are charged by the breaker cover enable accessories to be quickly identified by
an electric motor but can be manually charged if no power name and rating. These accessories are plug-in, providing for
is available. easy mounting and wiring to save both installation time and cost.
Spring release, shunt trip and undervoltage release are offered as
Power conductors are insulated and isolated in an engineered factory installed options or they can be easily mounted in the field
composite resin frame that provides protection to personnel in by user personnel. Internal accessories include auxiliary switches
front of the breaker. The levering-in device includes a safety (up to 6 NO and 6 NC contacts), overcurrent trip switch (Bell
interlock which prevents the door from being opened when the alarm) and an electrical operator can also be mounted at the
breaker is in the closed position. The breaker cannot be factory or in the field.
withdrawn when energized.
The advanced family of Digitrip RMS programmable trip units Pricing Instructions
were designed exclusively for Magnum. It uses proven This price list is to be used exclusively for pricing low voltage
microprocessor trip unit technology to provide expanded breakers and accessories for use by a low voltage panel
protection and information capabilities. assembler in the completion of a total switchgear assembly.
True RMS sensing trip units provide accurate coordination with All quotations from this price list will be per SP 25-000X dated
the conductors and equipment the breaker is designed to protect. March 1, 2002.
Basic protection is offered in the Digitrip RMS 220, 520, 520M and
520MC. Advanced protection is offered in the Digitrip RMS 1150
which can be programmed at the faceplate or with a PC.
800 Narrow 50/50 50/-- MWN5083LEA ABC $2,550 MWN5084LEA NABC $3,550
1000 Narrow 50/50 50/-- MWN5103LEA ABC $2,700 MWN5104LEA NABC $3,875
1250 Narrow 50/50 50/-- MWN5123LEA ABC $3,050 MWN5124LEA NABC $4,275
1600 Narrow 50/50 50/-- MWN5163LEA ABC $4,500 MWN5164LEA NABC $6,100
2000 Narrow 50/50 50/30 MWN5203LEA ABC $5,600 MWN5204LEA NABC $7,300
800 Narrow 65/65 65/40 MWN6083LEA ABC $2,650 MWN6084LEA NABC $4,025
1000 Narrow 65/65 65/40 MWN6103LEA ABC $2,750 MWN6104LEA NABC $4,300
1250 Narrow 65/65 65/40 MWN6123LEA ABC $2,950 MWN6124LEA NABC $4,550
1600 Narrow 65/65 65/40 MWN6163LEA ABC $4,850 MWN6164LEA NABC $6,175
2000 Narrow 65/65 65/40 MWN6203LEA ABC $5,850 MWN6204LEA NABC $7,350
800 Standard 85/85 85/65 MWI8083LEA ABC $3,125 MWI8084LEA NABC $4,425
1000 Standard 85/85 85/65 MWI8103LEA ABC $3,375 MWI8104LEA NABC $4,700
1250 Standard 85/85 85/65 MWI8123LEA ABC $3,825 MWI8124LEA NABC $4,975
1600 Standard 85/85 85/65 MWI8163LEA ABC $5,075 MWI8164LEA NABC $6,625
2000 Standard 85/85 85/65 MWI8203LEA ABC $6,300 MWI8204LEA NABC $8,400
2500 Standard 85/85 85/65 MWI8253LEA ABC $7,950 MWI8254LEA NABC $10,400
3200 Standard 85/85 85/65 MWI8323LEA ABC $9,375 MWI8324LEA NABC $12,875
800 Standard 100/85 (4) 85/65 MWIC083LEA ABC $3,500 MWIC084LEA NABC $4,875
1000 Standard 100/85 (4) 85/65 MWIC103LEA ABC $3,725 MWIC104LEA NABC $5,150
1250 Standard 100/85 (4) 85/65 MWIC123LEA ABC $4,225 MWIC124LEA NABC $5,400
1600 Standard 100/85 (4) 85/65 MWIC163LEA ABC $5,475 MWIC164LEA NABC $6,875
2000 Standard 100/85 (4) 85/65 MWIC203LEA ABC $6,575 MWIC204LEA NABC $8,775
2500 Standard 100/85 (4) 85/65 MWIC253LEA ABC $8,775 MWIC254LEA NABC $11,150
3200 Standard 100/85 (4) 85/65 MWIC323LEA ABC $9,975 MWIC324LEA NABC $12,950
4000 Double 65/65 65/-- MWI64N3LEA AABBCC $12,350 MWI64N4LEA NNAABBCC $16,300
4000 Double 85/85 85/-- MWI84N3LEA AABBCC $12,900 MWI84N4LEA NNAABBCC $17,800
5000 Double 85/85 85/-- MWI85N3LEA AABBCC $22,250 MWI85N4LEA NNAABBCC $30,010
6300 Double 85/85 85/-- MWI86N3LEA AABBCC $28,460 MWI86N4LEA NNAABBCC $38,288
4000 Double 100/100 100/-- MWIC4N3LEA AABBCC $14,700 MWIC4N4LEA NNAABBCC $20,010
5000 Double 100/100 100/-- MWIC5N3LEA AABBCC $24,250 MWIC5N4LEA NNAABBCC $31,900
6300 Double 100/100 100/-- MWIC6N3LEA AABBCC $30,460 MWIC6N4LEA NNAABBCC $40,800
(1) Magnum ACBs are 100% Thermal Rated (no de-rating necessary when properly applied in a specified enclosure).
(2) Interrupting Ratings shown are also applicable at 380V / 415V / 440V / 500V / 690V unless otherwise indicated.
(3) Phasing Left to Right when facing front of breaker. Neutral is rated 100% of continuous current.
(4) Icu is 100kA at 440Vac and 85kA at 690 Vac. Ics is 85kA at 690 Vac and below.
(5) Magnum ACBs carry an IT rating at 440 Vac per EN 60947-2 Annex H. Contact Cutler-Hammer for 690 Vac IT applications.
PL01301007E
Price List Magnum IEC
Page 4 Effective: May 2003 Air Circuit Breakers
800 Narrow 50/50 50/-- MWN5083HEA ABC $2,225 MWN5084HEA NABC $3,200
1000 Narrow 50/50 50/-- MWN5103HEA ABC $2,325 MWN5104HEA NABC $3,400
1250 Narrow 50/50 50/-- MWN5123HEA ABC $2,525 MWN5124HEA NABC $3,725
1600 Narrow 50/50 50/-- MWN5163HEA ABC $3,875 MWN5164HEA NABC $5,525
2000 Narrow 50/50 50/30 MWN5203HEA ABC $4,925 MWN5204HEA NABC $6,625
800 Narrow 65/65 65/40 MWN6083HEA ABC $2,325 MWN6084HEA NABC $3,625
1000 Narrow 65/65 65/40 MWN6103HEA ABC $2,425 MWN6104HEA NABC $3,975
1250 Narrow 65/65 65/40 MWN6123HEA ABC $2,825 MWN6124HEA NABC $4,450
1600 Narrow 65/65 65/40 MWN6163HEA ABC $4,375 MWN6164HEA NABC $5,725
2000 Narrow 65/65 65/40 MWN6203HEA ABC $5,325 MWN6204HEA NABC $6,750
800 Standard 85/85 85/65 MWI8083HEA ABC $2,725 MWI8084HEA NABC $4,150
1000 Standard 85/85 85/65 MWI8103HEA ABC $2,975 MWI8104HEA NABC $4,500
1250 Standard 85/85 85/65 MWI8123HEA ABC $3,387 MWI8124HEA NABC $4,850
1600 Standard 85/85 85/65 MWI8163HEA ABC $4,440 MWI8164HEA NABC $6,250
2000 Standard 85/85 85/65 MWI8203HEA ABC $5,625 MWI8204HEA NABC $7,875
2500 Standard 85/85 85/65 MWI8253HEA ABC $7,425 MWI8254HEA NABC $10,100
3200 Standard 85/85 85/65 MWI8323HEA ABC $8,725 MWI8324HEA NABC $12,275
800 Standard 100/85 (5) 85/65 MWIC083HEA ABC $2,925 MWIC084HEA NABC $4,075
1000 Standard 100/85 (5) 85/65 MWIC103HEA ABC $3,245 MWIC104HEA NABC $4,375
1250 Standard 100/85 (5) 85/65 MWIC123HEA ABC $3,700 MWIC124HEA NABC $4,675
1600 Standard 100/85 (5) 85/65 MWIC163HEA ABC $4,975 MWIC164HEA NABC $6,350
2000 Standard 100/85 (5) 85/65 MWIC203HEA ABC $6,100 MWIC204HEA NABC $8,230
2500 Standard 100/85 (5) 85/65 MWIC253HEA ABC $8,375 MWIC254HEA NABC $10,750
3200 Standard 100/85 (5) 85/65 MWIC323HEA ABC $9,575 MWIC324HEA NABC $12,550
4000 Double 65/65 65/-- MWI64N3HEA AABBCC $11,100 MWI64N4HEA NNAABBCC $14,070
4000 Double 85/85 85/-- MWI84N3HEA AABBCC $11,750 MWI84N4HEA NNAABBCC $15,200
5000 Double 85/85 85/-- MWI85N3HEA AABBCC $18,700 MWI85N4HEA NNAABBCC $26,150
6300 Double 85/85 85/-- MWI86N3HEA AABBCC $24,100 MWI86N4HEA NNAABBCC $34,150
4000 Double 100/100 100/-- MWIC4N3HEA AABBCC $13,075 MWIC4N4HEA NNAABBCC $16,200
5000 Double 100/100 100/-- MWIC5N3HEA AABBCC $19,700 MWIC5N4HEA NNAABBCC $27,600
6300 Double 100/100 100/-- MWIC6N3HEA AABBCC $25,900 MWIC6N4HEA NNAABBCC $36,100
(1) Magnum ACBs are 100% Thermal Rated (no de-rating necessary when properly applied in a specified enclosure).
(2) Interrupting Ratings shown are also applicable at 380V / 415V / 440V / 500V / 690V unless otherwise indicated.
(3) Fixed breakers have (H) horizontal terminals. Vertical adapters (V) are priced separately.
(4) Phasing Left to Right when facing front of breaker. Neutral is rated 100% of continuous current.
(5) Icu is 100kA at 440Vac and 85kA at 690 Vac. Ics is 85kA at 690 Vac and below.
(6) Magnum ACBs carry an IT rating at 440 Vac per EN 60947-2 Annex H. Contact Cutler-Hammer for 690 Vac IT applications.
Magnum IEC Price List
Air Circuit Breakers Effective: May 2003 Page 5
Special Application – 1100 Vac Air Circuit Breakers – Drawout & Fixed Mounting
Basic Drawout Mounted Circuit Breaker
Tested to EN 60947-2 Cat B; witnessed and certified with a KEMA-KEUR Mark.
List prices for Basic Drawout Mounted Air Circuit Breakers include: Manually operated breaker frame (moving portion) only with primary
disconnecting contacts (finger clusters) and one current sensor per phase.
Breaker list prices do not include a trip unit, accessories, or cassette. Each must be priced separately.
3200 Standard 25/25 ---- / ---- MWK2323LEA ABC $9,375 MWK2324LEA NABC $12,875
3200 Standard 25/25 ---- / ---- MWK2323HEA ABC $8,725 MWK2324HEA NABC $12,275
(1) Magnum ACBs are 100% Thermal Rated (no de-rating necessary when properly applied in a specified enclosure).
(2) Fixed breakers have (H) horizontal terminals. Vertical adapters (V) are priced separately.
(3) Phasing Left to Right when facing front of breaker. Neutral is rated 100% of continuous current.
Catalogue Number
Magnum Fixed Continuous Short Circuit
Position 8 Terminal Description Breaker Terminals Poles List Price in US$
Breaker Frame Current Rating (A) Rating (kA)
Factory Fitted
H Horizontal Terminals Upper and Lower Terminals All Frames 3 or 4 Pole All Ratings All Ratings $0
V Vertical Adapters Upper and Lower Terminals Narrow 3 800 - 2000 A 65 kA $285
V Vertical Adapters Upper and Lower Terminals Standard 3 800 - 1600 A 65 kA $285
V Vertical Adapters Upper and Lower Terminals Standard 3 800 - 2000 A 100 kA $375
V Vertical Adapters Upper and Lower Terminals Standard 3 2500 - 3200 A 100 kA $475
V Vertical Adapters Upper and Lower Terminals Double 3 4000 A 100 kA $750
V Vertical Adapters Upper and Lower Terminals Double 3 5000 - 6300 A 100 kA $950
V Vertical Adapters Upper and Lower Terminals Narrow 4 800 - 2000 A 65 kA $380
V Vertical Adapters Upper and Lower Terminals Standard 4 800 - 1600 A 65 kA $380
V Vertical Adapters Upper and Lower Terminals Standard 4 800 - 2000 A 100 kA $500
V Vertical Adapters Upper and Lower Terminals Standard 4 2500 - 3200 A 100 kA $575
V Vertical Adapters Upper and Lower Terminals Double 4 4000 A 100 kA $1,000
V Vertical Adapters Upper and Lower Terminals Double 4 5000 - 6300 A 100 kA $1,150
Price List Magnum IEC
Page 6 Effective: May 2003 Air Circuit Breakers
Internal Accessories
Factory Fitted Current Sensors and Rating Plugs
Basic Breaker List Price includes one rating plug and one sensor per pole.
Select the Current Sensor and Rating Plug rating by ACB Frame.
Select NN if ACB is Non-Automatic (Switch Disconnector).
For 3 pole breaker earth fault applications on 3 phase, 4 wire circuits, external neutral mounted sensors must be ordered separately.
NN - None
20 2000
16 1600 1600
13 1250 1250 1250
12 1200 1200 1200
10 1000 1000 1000 1000
08 800 800 800 800 800
07 630 630 630 630 630
06 600 600 600 600 600
04 400 400 400 400 400
03 300 300 300 300 300
05 250 250 250 250 250
02 200 200 200 200 200
NN - None
32 3200
25 2500 2500
20 2000 2000 2000
16 1600 1600 1600 1600
13 1250 1250 1250 1250 1250
12 1200 1200 1200 1200 1200
10 1000 1000 1000 1000 1000 1000
08 800 800 800 800 800 800 800
07 630 630 630 630 630 630 630
06 600 600 600 600 600 600 600
04 400 400 400 400 400 400 400
03 300 300 300 300 300 300 300
05 250 250 250 250 250 250 250
02 200 200 200 200 200 200 200
NN - None
63 6300
50 5000 5000
40 4000 4000 4000
32 3200 3200 3200
25 2500 2500
20 2000
Magnum IEC Price List
Air Circuit Breakers Effective: May 2003 Page 7
NN Non-Automatic (5) 3-Pole ACB Not Applicable None Narrow/Standard DEDUCT $150
NN Non-Automatic 3-Pole ACB Not Applicable None Double DEDUCT $300
NN Non-Automatic (5) 4-Pole ACB Not Applicable None Narrow/Standard DEDUCT $180
NN Non-Automatic 4-Pole ACB Not Applicable None Double DEDUCT $400
MT 520M LSI 24/48 Vdc High Load Alarm All Frames $1,444
MU 520M LSI 120 Vac High Load Alarm All Frames $1,444
MV 520M LSI 240 Vac High Load Alarm All Frames $1,444
MJ 520Mi LSIG 24/48 Vdc Ground Trip All Frames $1,809
MK 520Mi LSIG 120 Vac Ground Trip All Frames $1,809
ML 520Mi LSIG 240 Vac Ground Trip All Frames $1,809
ME 520Mi LSIA 24/48 Vdc Ground Alarm All Frames $1,809
MC 520Mi LSIA 120 Vac Ground Alarm All Frames $1,809
MF 520Mi LSIA 240 Vac Ground Alarm All Frames $1,809
CT 520MC LSI 24/48 Vdc High Load Alarm All Frames $1,689
CU 520MC LSI 120 Vac High Load Alarm All Frames $1,689
CV 520MC LSI 240 Vac High Load Alarm All Frames $1,689
CJ 520MCi LSIG 24/48 Vdc Ground Trip All Frames $2,052
CK 520MCi LSIG 120 Vac Ground Trip All Frames $2,052
CL 520MCi LSIG 240 Vac Ground Trip All Frames $2,052
CE 520MCi LSIA 24/48 Vdc Ground Alarm All Frames $2,052
CC 520MCi LSIA 120 Vac Ground Alarm All Frames $2,052
CF 520MCi LSIA 240 Vac Ground Alarm All Frames $2,052
(1) Digitrip 520MC Trip Unit requires Pow-R-Net Software version 3.2 or higher if Pow-R-Net is used.
(2) Power Relay Module mounted integral to ACB receives power from an external customer supplied source wired through the breaker secondary contacts.
The external source powers the trip unit digital display (520M, 520MC, & 1150), communications functions (520MC and 1150), and relays.
(3) No Power Relay Module provided for the 520M trip unit when this catalogue code is selected. The Digital display powered from current sensors
and the ACB must carry 20% rated sensor current to power digital display.
(4) Digitrip 1150 has programmable relay trip or alarm contacts for trip unit protective and high load functions.
(5) The maximum available instantaneous interrupting rating for the Magnum Standard Frame Non-Automatic Air Circuit Breaker is 85kA when the breaker is used
with a suitable external overcurrent protective device with instantaneous protection.
Digitrip 220 Trip Unit Digitrip 520i Trip Unit Digitrip 520Mi Trip Unit Digitrip 520MCi Trip Unit Digitrip 1150i Trip Unit
Price List Magnum IEC
Page 8 Effective: May 2003 Air Circuit Breakers
N None $0
A 110 - 127 Vac/dc $196
R 208 - 250 Vac/dc $196
C 24Vdc $196
H 48Vdc $196
Motor Operator
Factory fitted option for fixed or drawout breakers.
For Electrically Operated breakers, price and select a Motor Operator, and Spring Release Device and (if required)
a Shunt Trip Attachment (STA).
Catalogue Number
Voltage
Position 16 List Price in US$
(AC:50/60 Hz)
Factory Fitted
M Manual Operated $0
N 110 - 125 Vac $960
P 220 - 250 Vac $960
L 24 Vdc $960
K 48 Vdc $960
W 110 - 125 Vdc $960
T 220 - 250 Vdc $960
N None $0
A 110 - 127 Vac/dc $196
R 208 - 250 Vac/dc $196
C 24Vdc $196
H 48Vdc $196
N None None $0
A 110/127Vac Instantaneous $340
R 208/240Vac Instantaneous $340
C 24Vdc Instantaneous $340
H 48Vdc Instantaneous $340
E 110/125Vdc Instantaneous $340
F 220/250Vdc Instantaneous $340
G 32Vdc Instantaneous $340
X 380/415Vac Instantaneous $340
J 480Vac Instantaneous $340
K 600Vac Instantaneous $340
1 110/127Vac Second Shunt Trip $196
2 208/250Vac Second Shunt Trip $196
3 24Vdc Second Shunt Trip $196
4 48Vdc Second Shunt Trip $196
N None $0
2 2a/2b $80
4 4a/4b $160 (1) 4a/4b Maximum contacts on Narrow Frame
6 6a/6b $240 (2) 6a/6b Maximum on Double or Standard Frames
(1) Refer applications requiring 6a/6b contacts on the Narrow Frame Breaker to Cutler-Hammer.
(2) Except when a second Shunt Trip Attachment is selected, which occupies a 2a/2b contact mounting position.
E No No $0
N Yes No $75
Y Yes Yes $118
N None $0
M Metal Frame (Open and Close) $144
P Plastic Frame (Open and Close) $144
C Block Close PB Metal Frame $144
H Block Close PB Plastic Frame $144
N No Counter No Lock $0
K No Counter Kirk lock $72
C No Counter Castell Lock $72
R No Counter Ronis lock $72
A Operations Ctr No Lock $133
Y Operations Ctr Kirk lock $206
L Operations Ctr Castell Lock $206
H Operations Ctr Ronis Lock $206
(1) Key interlock provision Includes a hole in the front cover with cap plus provisions hardware kit for
customer installation of customer supplied cylinder lock.
(1) Form C contact wired through breaker secondary contacts for external customer use.
Price List Magnum IEC
Page 10 Effective: May 2003 Air Circuit Breakers
Drawout Breakers
Magnum Double Frame breakers are always shipped separately from the cassette.
For Drawout Circuit Breakers, catalog position 24 is only to specify the drawout breaker and cassette shipping instructions.
Cassettes and cassette options are not included in the Basic Breaker List Price and are priced separately.
Configure and price the cassette and cassette options using the cassette catalog number system.
Catalogue Number
Position 25 Description List Price in US$
(Future Option)
Cassette Catalogue
Description List Price in US$
Number Position 7
DN Included $0
XN Not Included Deduct $20
Cassette Shutters
Factory Fitted cassette shutters.
Narrow Frame Cassette - Rear View
Shutters are also available as a field installable kit for customer installation.
Secondary Terminal Block Kit MSECBK Qty 15 6-Point Terminal Blocks With Labels $310
Secondary Terminal Wire Kit MSECWR Qty 90 Wires for Connecting Secondary Blocks $172
Secondary Terminal Wire Kit MWK40 Qty 30 Wires 40 Inches Long for Fixed ACB Connecting Secondary Blocks Contact C-H
Secondary Terminal Kit With Tool (1) MSECTOOL Qty 12 Wires, Qty 2 6-Point Terminal Bocks, & 1 Amp, Inc Removal Tool Contact C-H
(1) Pin Removal Tool can be purchased directly from AMP Corporation under Part Number # 3205183
MLSC1 Latch Check Switch for Wiring Internally to Spring Release $210
MLSC2 Latch Check Switch With 1 Form C Contact For Remote Indication $210
Trip Indication Kit Description (1) Contacts Catalogue Number List Price in US$
AB
Type 2 Across 2 Breakers One Normal Power Supply (A) 0 0
One Emergency Power Supply (B) 1 0
0 1
ABC
Type 31 Across 3 Breakers Two Normal Power Supplies (A and C) 0 0 0
One Emergency Power Supply (B) 1 0 0
Circuit breakers A and C can be closed if B 0 1 0
is open. B can only be closed if A and C are open. 0 0 1
1 0 1
ABC
Type 32 Across 3 Breakers Two Power Supplies (A and C) 0 0 0
One Bus Tie Breaker (B) 1 0 0
0 1 0
One or two breakers out of 3 can be 0 0 1
closed at the same time. 1 1 0
0 1 1
1 0 1
ABC
Type 33 Across 3 Breakers Three power supplies (A, B, and C) 0 0 0
normal or emergency. Only one of which 1 0 0
can be closed at a time. 0 1 0
0 0 1 2-Way Cable Interlock
2 Way Fixed Rod Type 2 MI2FR $755 This Kit also requires 1 Rod Kit
2 Way Fixed Cable Type 2 MI2FC $755 This Kit also requires 1 Cable Kit
3 Way Fixed Cable Type 31 MI31FC $1,205 This Kit also requires 2 Cable Kits
3 Way Fixed Cable Type 32 MI32FC $1,305 This Kit also requires 3 Cable Kits
3 Way Fixed Cable Type 33 MI33FC $1,205 This Kit also requires 3 Cable Kits
2 Way Drawout Rod Type 2 MI2DR $705 This Kit also requires 1 Rod Kit
2 Way Drawout Cable Type 2 MI2DC $705 This Kit also requires 1 Cable Kit
3 Way Drawout Cable Type 31 MI31DC $1,155 This Kit also requires 2 Cable Kits
3 Way Drawout Cable Type 32 MI32DC $1,255 This Kit also requires 3 Cable Kits
3 Way Drawout Cable Type 33 MI33DC $1,155 This Kit also requires 3 Cable Kits
Rod Type Kit MIR $225 Includes 2 Rods 3 Foot Long (910 mm) each
Cable Type Kit MIC5 $485 Includes 2 Cables 5 Feet Long (1520 mm) each
Cable Type Kit MIC6 $515 Includes 2 Cables 6 Feet Long (1830 mm) each
Cable Type Kit MIC8 $555 Includes 2 Cables 8 Feet Long (2440 mm) each
Cable Type Kit MIC10 $595 Includes 2 Cables 10 Feet Long (3050 mm) each
Price List Magnum IEC
Page 18 Effective: May 2003 Air Circuit Breakers
Levering Device None Required Special levering device not required. Use 10 mm Socket & Drive Set
Lifting Yoke (3 Pole Narrow Frame) 8651C91G09 Fits 3 Pole Narrow Frame ACB Contact C-H
Lifting Yoke (3 Pole Standard Frame) 8651C91G02 Fits 3 Pole Standard Frame ACB $225
Lifting Yoke (3 Pole Double Frame) 8651C91G05 Fits 3 Pole Double Frame ACB $375
Lifting Yoke (4 Pole Narrow Frame) 8651C91G10 Fits 4 Pole Narrow Frame ACB Contact C-H
Lifting Yoke (4 Pole Standard Frame) 8651C91G07 Fits 4 Pole Standard Frame ACB Contact C-H
Lifting Yoke (4 Pole Double Frame) 8651C91G08 Fits 4 Pole Double Frame ACB Contact C-H
Roll on Floor Lifting Device 6727D63H20 Lifts breaker fitted with lifting yoke from above $5,250
Magnum Trip Unit Tester MTST1 Hand-Held Tester for Digitrip 220, 520, 520M, & 520MC Trip Units $2,605
Triplink Cable 5720B59G01 Downloads Trip Unit Settings From One Digitrip RMS 1150 Trip to Another $475
Door Escutcheon Kit MDES Escutcheon, Gasket & Mounting Hardware $90
IP54 Door Cover Kit MDESC IP54 Cover, Gasket & Mounting Hardware $320
Non-Automatic ACB Cover MTUNACI Covers Trip Unit Cavity on Non-Automatic Breakers Contact C-H
Cassette Rejection Bracket Kit MCELLREJBK ABC Rejection Kit (Cassette Mounting) $87
Capacitor Unit for ACB Capacitor Trip Contact CH Enclosure Mounted AC Capacitor Unit for ACB Capacitor Trip Contact C-H
Peripheral Devices
Mmint MODBUS Translator MMINT Translates INCOM for up to 32 Communicating Trip Units to Modbus $1,695
Digital Relay Accessory Module DRAM Used with Accessory Bus on Digitrip 1150 Trip Unit Contact C-H
Magnum IEC Price List
Air Circuit Breakers Effective: May 2003 Page 19
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
M W A – X
3. Breaker Frame 11 & 12. Sensor & Rating 16. Motor Operator 21. Padlock Provisions for Blocking
Plug Rating Close and/or OpenACB Manual
I = Standard or Double M = Manual Operated
Push Buttons
N = Narrow NN = None 13 = 1250 N = 110 - 125 Vac
K = Special 1100 Vac ACB 02 = 200 16 = 1600 W = 110 - 125 Vdc N = None
05 = 250 20 = 2000 T = 220 - 250 Vdc M = Metal (Block Close & Open)
03 = 300 25 = 2500 P = 220 - 250 Vac P = Plastic (Block Close & Open)
4. Interrupting Icu 04 = 400 30 = 3000 L = 24 Vdc C = Metal (Block Close Only)
4 = 40kA 06 = 600 32 = 3200 K = 48 Vdc H = Plastic (Block Close Only)
5 = 50kA 07 = 630 40 = 4000
6 = 65kA 08 = 800 50 = 5000
10 = 1000 63 = 6300 17. Spring Release Device (SRD) 22. Operations Counter
8 = 85kA and/or Keylock Provisions
C = 100kA 12 = 1200 N = None
2 = 25kA (1100 Vac MWK) A = 110 - 127 Vac/dc Counter Keylock Provisions
R = 208 - 240 Vac/dc
13 & 14. Trip Unit & Protection, N= No Counter No Lock
C = 24 Vdc
5 & 6. Continuous Amperes & Phasing (& External Control Voltage K No Counter Kirk Lock
H = 48 Vdc
(Facing Front of Breaker) When Required) C No Counter Castell Lock
R No Counter Ronis Lock
08 = 800 ABC NN = Non-Automatic (No Trip Unit)
A Counter No Lock
10 = 1000 ABC 22 = 220 LI 18. UnderVoltage Release (UVR)
T Counter Kirk Lock
12 = 1250 ABC 52 = 520 LSI or 2nd ShuntTrip Attachment (STA)
L Counter Castell Lock
16 = 1600 ABC 5W = 520i LSIG
N = None H Counter Ronis Lock
20 = 2000 ABC M2 = 520M LSI
A = 110 - 127 Vac
25 = 2500 ABC MT = 520M LSI (24 - 48 Vdc)
R = 208 - 240 Vac
32 = 3200 ABC MU = 520M LSI (120 Vac) 23. Latch Check Switch / Trip Unit
C = 24 Vdc
4N = 4000 AABBCC MV = 520M LSI (240 Vac) Metering Voltage Connection for
H = 48 Vdc
5N = 5000 AABBCC MW = 520Mi LSIG Digitrip 1150 Trip Unit
E = 110 - 125 Vdc
6N = 6300 AABBCC MJ = 520Mi LSIG (24 - 48 Vdc)
F = 220 - 250 Vdc Latch 1150 Voltage
40 = 4000 ABCABC MK = 520Mi LSIG (120 Vac)
G = 32 Vdc Check Sw Connection
50 = 5000 ABCABC ML = 520Mi LSIG (240 Vac)
X = 380 - 415 Vac
60 = 6300 ABCABC ME = 520M LSIA (24 - 48 Vdc) N = None Upper Terminals
J = 480 Vac
MC = 520M LSIA (120 Vac) M = None Lower Terminals
K = 600 Vac
MF = 520M LSIA (240 Vac) L = LCS Wired Upper Terminals
1 = 2nd STA, 110 - 127 Vac/dc
7. Poles & Neutral (Facing Front CT = 520MC LSI to SRD
2 = 2nd STA, 208 - 240 Vac/dc
of Breaker) CU = 520MC LSI Y = LCS Wired Lower Terminals
3 = 2nd STA, 24 Vdc
CV = 520MC LSI to SRD
3 = Three 4 = 2nd STA, 48 Vdc
CE = 520MC LSIA C = LCS Wired Upper Terminals
4 = Four (Neutral Left)
CC = 520MC LSIA External
R = Four (Reserved for
CF = 520MC LSIA 19. Auxillary Switch D = LCS Wired Lower Terminals
Neutral Right)
CJ = 520MCi LSIG External
CK = 520MCi LSIG N = None
CL = 520MCi LSIG 2 = 2A/2B
8. Mounting Configuration
1W = 1150i LSI (24 - 48 Vdc) 4 = 4A/4B 24. ACB Shipping Instructions
& Load Terminals
1N = 1150i LSI (120 Vac) 6 = 6A/6B
A = Fixed ACB with Door Kit
H = Fixed Horizontal 1P = 1150i LSI (240 Vac)
F = Fixed ACB w/o Door Kit
V = Fixed Vertical 1R = 1150i LSIG/A (24 - 48 Vdc)
20. Bell Alarm Switch (OTS) with A = D/O ACB only w/o Door Kit
L = Drawout Horizontal 1S = 1150i LSIG/A (120 Vac)
2a/2b Contacts and/or Mechnical C = D/O ACB in Cassette (Un-Wired)
1T = 1150i LSIG/A (240 Vac)
Trip Indicator P = D/O ACB in Cassette (Pre-wired)
9. Nameplate Language S = D/O ACB in Cassette (Shutters)
OTS 2a/2b Trip Indicator W = D/O ACB in Cassette
15. Shunt Trip Attachment (STA)
E = English E= No OTS No Ind (Pre-wired & Shutters)
A = Spanish N = None N= No OTS With Ind Double Frame D/O ACBs Ship
A = 110 - 127 Vac Y= With OTS With Ind Without Cassette
R = 208 - 240 Vac
C = 24 Vdc
H = 48 Vdc
25. Future Use
X = All ACBs
Price List Magnum IEC
Page 20 Effective: May 2003 Air Circuit Breakers
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
N H N N N N N C