a 161 mm
Anchor Bolt Projection (a) b 150 mm
A 7247 mm
B 2400 mm
C 800 mm
This document is the property of Aster Private Limited, IBO Division - HYD. and must not be passed on to any third person or firm not authorised by us, nor be copied/made use of in full or part by such person or firm without our prior permission writing
D 3000 mm
E 300 mm
F 300 mm
G 1200 mm
T1 T 12@150mm C/C
T2 T 20@180mm C/C
T3 T20-24Nos.
T4 T 8@225mm C/C
T5 T 8@225mm C/C
100 T6 T 12@300mm C/C
T7 T 12@750mm C/C
T8 T 12@750mm C/C
100
C
SECTION 'X-X' T3
(Anchor Bolt details are not shown for clarity)
T4
T5
C
SECTION 'A-A'
FOUNDATION FORCES
(UNFACTORED)
DOWNTHRUST 746 KN
UPLIFT 692 KN
SIDE THRUST 69 KN
C/C OF TOWER 7.2470 M
FOR CONSTRUCTION
NOTES:
1. CONCRETE GRADE TO BE M25 (DESIGN MIX AS PER BS:8110)
2. PCC GRADE TO BE M10
3. ALL STEEL TO BE FE460 GRADE CONFIRMING TO BS:4449
4. CEMENT SHALL BE OPC 43 GRADE CONFIRMING
TO BS:8110
5. MINI. CLEAR COVER FOR COLUMNS SHALL BE 50MM
TOWER FOUNDATION PLAN FOR FOOTING 50MM
6. USE CHAIRS/SPACERS REQUD. TO KEEP REIN. IN POSITION
7. DRAWING SHALL NOT BE SCALED & ONLY WRITTEN DIMENSION
SHALL BE FOLLOWED
8. ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE SPECIFIED
9. DRINKING WATER SHALL BE USED IN CONCRETE & CURING
10. CONCRETE SHALL BE MACHINE MIXED
11. CONCERTE SHALL NOT BE PLACED DURING RAIN
FOUNDATION VOLUMES 12. CONCRETE SHALL BE CONTINIOUS
EXCAVATION = 97.22 Cu.m 13. ALL M.S/TOR BARS SHALL BE PROVIDED WITH STANDARD END HOOKS
PCC = 2.70 Cu.m 14. ALL LAPS SHALL BE WELDED CONTINUOUSLY FOR MINIMUM LENGTH OF 750MM
REIN.STEEL = 2530 Kgs 15. LAPS SHALL BE STAGGERED WITH ATLEAST MINIMUM DISTANCE OF 1M
CONCRETE = 15.17 Cu.m IN ALTERNATIVE DIRECTION.
16. S.B.C OF SOIL = 150KPA.
ASTER PRIVATE LIMITED. NAME DATE
(Formerly known as Aster Teleservices Pvt.Ltd.,) DESIGNED BINDU 19-Feb-14
IBO DIVISION - SECUNDERABAD CADD BINDU 19-Feb-14
MP-INFRA-
REF.DRG.: AST\TOWER\72M\GA\151 SITE : SHEET NO: 1 Of 2
Page 1 Of 2
This document is the property of Aster Private Limited, IBO Division - HYD. and must not be passed on to any third person or firm not authorised by us,
b
2 200 2300 -- 2700 128 12 0.89 307
a a
a b a
3 200 2300 -- 2700 112 20 2.47 746
nor be copied/made use of in full or part by such person or firm without our prior permission writing
a
4 b b 650 200 -- 1550 80 12 0.89 107
COLUMN:
6
b 700 700 -- 2992 60 8 0.39 71
a
a
TOTAL 2530 Kgs
MP-INFRA-
REF.DRG.: AST\TOWER\72M\GA\151 SITE : SHEET NO. 2 OF 2
2 Of 2