Professional Documents
Culture Documents
DN10V-4DS.M7.19.G9 - FRIOPACKING - 14032018 - Backup
DN10V-4DS.M7.19.G9 - FRIOPACKING - 14032018 - Backup
power [kW]
Pressure type: static 90 25
40
Temperature: 0 °C 80
Altitude: 400 m
Humidity: 0%
70 20
100 30
Humidity abs.: 0 g/kg dry air 60
Air Density: 1,23 kg/m3 50 15
Measuring category (ISO 5801): D (ducted) 20
Fan characteristics: 40
10
Design: S (short cas. with inlet) 50 30
Diameter: 1000 mm 10 20 5
Temp. range: -20/50 °C
ATEX range: none 10
Casing finish: G - hot dip galv. steel 0 0 0 0
Mouting position: H/V (horizontal and vertical) 0 20000 40000 60000 80000
Location: inside
airflow [m3/h]
Impeller data:
pressure facility curve duty point
Airflow direction: V (impeller -> motor)
Nb of blades: 9
Blade setting: 19° working limit at 0°C Lw suc. side [dBA] scale sound data
Blade Material: ZAmid
Impeller bolting: A2
Special treatment alu parts: no efficiency static scale efficieny shaft power
Hub cover: yes
Performance curve given at best aerodynamical configuration.
Counter rotation: no
Motor information - Rating plate data:
Accessories:
Guard grill impeller side: no Brand: ZA-MOTOR
Guard grill motor side: no ATEX range: none
Inlet bell mouth: no Size: 180L
Shaft power (P2): 25,3 kW
Achieved duty point: Supply: 440 V | 3~ | 60Hz
Airflow: 64148 m3/h Design: IM B3, IM 1001
Static Pressure: 57,2 mm H20 Current: 40,2/23,3 A
Shaft power (P2): 24,9 kW Eff. (100%): 91,6% (IE2)
Total Pressure: 89,5 mm H20 Power factor: 0,86
Dynamic pressure: 32,3 mm H20 Rated speed: 1764 /min (4 pole)
Input power (P1): 27,2 kW Deg. of protection: IP55
Imp. static eff.: 40,1 % Thermal class: THCL 155
Current max.( 440 V): 44,8/25,9 A Temp.range: -20/40 °C
Disclaimer: Load factors are not taken into account in Optimiser. Motor protection: PTC
Sound data:
A weighted sound power Lw (dBA):
Suction side: 105
Pressure side: 106
Sound pressure (dBA):
At 3 m, half sphere configuration:
Suction side: 87
Pressure side: 88
Sound power levels:
Octaves (Hz) 63 125 250 500 1k 2k 4k 8k 16k
Suction side (dBA) 57,1 78,1 93,5 98,3 98,8 97,9 96,7 87,1 74,4
Pressure side (dBA) 58,5 74,9 92,3 99,3 100 98,9 97,8 90,1 76,7
Suction side (dBL) 81,1 92,8 103 101 98,9 96,8 95,7 87,6 80,1
Pressure side (dBL) 82,7 90,3 102 102 100 97,8 96,9 90,6 82,3
Noise calculation are at actual duty point.
Sound data is calculated and should be used as a guideline only.
This datasheet has been generated by Bruno GENEROSO the 13/3/2018 - 14:08 using version 2.2.6 of the MAXvent selektor.
sheet: 2/2