Point of ○ Run CPU ○ DI2, DI4

TCD - 037 INV Overheating [U,V,W phase] (DS4) Application


Detection ● Speed CPU ● DS4

[Meaning] [Actions to take]


When thermal switch on heating plate operates to prevent IGBT damage by overheating.
1.Check STACK to see if FAN operates or not.
2.Check FAN driving power and RELAY.
[Diagram] 3.Check VGC connector status in DPC-310 and DPP-320 PCB with
power OFF.
4.If ambient temperature of machine room exceeds 40℃, see if air-
conditioner is operating or not.
P15 5.Check the voltage of VGC-7 when VGC connector is normally
P15
DPP- 320 R107
R116 connected to DPC-310 and emission plate is cooled enough.
P15
R37
2 THEM VGC -07 VGC -07 THEM #
GET- E18
6
R117
- If voltage is high(+5V) ,
1
HIC- 37 7 GND VGC - 17 VGC -17 C65 +

R108 C56
a) Replace thermal Guard
GR-06
GR-02 b) Replace DPP-320 PCB
GS- 06 DPC- 310 6.Check the GDC fuse of control transformer.
GS-02
GT- 06

N9 GT-02

It should be외부에서
shorten
Short Thermal Guard

from outside 시켜야 함