Written for
Model DHG9140A
~lUZEREN
Summary
Provided to industrial and mining enterprises,laboratories and scientific resear
Temperature
0.1 °C/±0.5°C
precision/stability
Electrical
110V 60Hz 380V 50Hz
requirement
Power 1250W 1500W 2100W 4000W 4500W 6000W
transportation.
3. Don't use the instrument in the place where is sunlight or heat damp.
5. The equipments while circulating normally, product inside the box's putting
6. The power cable never mind depends a behind, also not let the instrument
Usage
1. Open the door and need the processing articíe to put to put plank into the
2. Connect power supply, insert the power supply plug into the AC outlet, the
power switch of the front-panel place in the position of "open", the gauge
4. The instrument begins to work, temperature inside the box atlains initial
value gradually, time through the dry processing need after, handle a work
completion.
5. Close power supply, need temperature inside the box to open to put the
spirit valve after near to the environment temperature. Open the door, take
out article.
1. Product didn't carry on correction generally through strict test before the
manifestation value and actual temperature error margin inside the box, if
outrun the technique index sign scope of, can revise, concretely the step
lead to grow, after closing a box of door temporarily temperature inside the
3. Atlention of testing: The thermometer that test inside the box use wants to
use 1.0 mercury thermometer of the accuracies, and put mercury to the
2
Panel Function
CD PV display unit
Displays measured value or the
Controller Details
various characters depending the
statue of the instrument.
Configuration of the Instrument Panel
® SV display unit
Displays the set value or the timing
PV
_1 and rated parameters.
® Indicators
RUN/AT
1....----1
Working indicator (Green); Flashes
sv during auto-tuming execution.
OUT
O o O O Heating output indicator (Green)
MK
~
Set
GJ [YJ
Shift DEC/Restart
~
INC/Mute
lhis machine hasn't this kind of
function. (Door Control Function)
ALM
ALMalarming indicator (Red)
Tumed on when alarming output
operate and the buzzer sounds.
Operating
When it is switched on, the upper row displays "1 nP" and the low row
Press the temperature menu button "Set ", the controller runs into the
temperature I time setting state, the under window of controller displays the
symbol of temperature setting "SP", and the over window of the displays the
set value of temperature, the user can adjust the value according to the needs.
Re-press the button, the controller runs into the time setling state, the under
window of controller displays the symbol of time setting "SI:", the over window
displays the set value of time, the user can adjust the value according to
needs (0-9999) (If the working time is set as 0000, it indicates the timer is
inoperative, the controller will run continuously.) Press the button again, then
it returns to the running state. Press the menu button of temperature for 3
seconds, it runs into the internal value setting state; if press another 3 seconds,
it will return to the running state. In the above mentioned 2 states, if there is not
any operation for 30s, the controller will auto quit the above mentioned states
and the adjusted value will not be saved. When the runtime is over, the over
3
window of controller will display "End", the buzzer will sound for 30s, then it
can be muted by pressing the button " • ". When press the button "~"for 4s at
When temperature is beyond "SP+RL ". the ALM indicator turns on.
Press Set key the low row displays SP. Pressé," or "~"key, the upper
row displays the needed value. Again press Set key the low row displays St
key. Press"." or "~" key, the upper row displays the timing time needed.
Again press Set key, the instrument return to the standard display mode.
• Timing function
Otherwise when the value of St is not setting to zero the timing function is
available.
When the power is turned on, the timing function starts. In case of
achieving the setting timing the heating output is close. and the buzzer sounds
four times to notice the operator. When the system is starting with auto tuning,
the timing function is also canceled. When the auto tuning process is
completed, the timing function would start again. During the operating period of
the instrument, it is allowed to update the value of St online, and the time
passed can be memorized and the instrument will operate the updated timing
time. When the updated time is less than the passed accumulative time, the
After press Set key over 4 seconds, find L[. Then press " ." or "~"key to
the upper displayer display 3.Again press the Set key to find the symbol
character for the needed parameter. Through press the "." or "~"key till the
parameters may be setting at once. Press the Set key over 4 seconds the
4
• The function of the controller Auto- Tuning
After pressing ••••key 6 seconds the AT indicator flashes and the
auto-tuning press starts; after the end of auto-tuning the AT indicator then be
turned out. A set of PIO parameters can be got automatically for overcoming
In the period of auto tuning, if presses Shift key beyond 6 seconds the AT
indicator turn out and the auto tuning process is canceled. The instrument
Proportional
P-- P band
Adjustment of proportional function. 20.0~80.0
5
Electrical circuit diagram
U
Heater
1IlOVAC1
Regulation
1. Chemistry product of the combustibility and volatility isn't put absolutely
during the period of use, please turn off power immediately, the customer
3. The box inner part and the equipments surface want to usually wipe to
sweep by keep, the clarity of the increment glass. Don't use sour, the alkali
4. The equipments don't work for long-term, it should be pulled out power
cable in order to prevent the equipments hurt a persono Should press the
2-3 days also to banish the dampness of the electric appliances part, avoid
Packing List
NO. Description of goods Quantity Remarks
1 Drying Oven 1
6
Protection to Fix Card
Thank you very much for using our products
Product Name:
Product Model Number:
Product Trouble:
Customer Name:
Company Name:
Customer Phone:
Customer Address:
Post Codes:
E-mail:
(Purchase Date)
Please tell the serial number to our product engineer for repairing.