INV HCT Error (DS4) : Run CPU Speed CPU DI2, DI4 DS4

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Point of ○ Run CPU ○ DI2, DI4

TCD - 036 INV HCT Error(DS4) Application


Detection ● Speed CPU ● DS4

[Meaning] [Actions to take]


When HCT and HCT cable or HCT cable and VBN connector of DPC-310 PCB are badly
connected or not inserted.
1.Check the VBN connector status in DPC-310(INV) PCB .
2.Check the VBN wiring status in DPC-310(INV) PCB
[Explanation] 1. It will occur in case connector which is connects HCT and DPC-310 is not
inserted. ( Verify if No.13 and 14 of VB jack are connected well.)

2. If VGI side connection of DPC-310 is wrong, TCD36 will happen when lift If TCD 36 happen when elevator stops, VBN connector of DPC-310

stops and runs. Else if HCT side is wrong, it will happen as soon as it status is wrong. Else if it happens when system starts switching

switching to IGBT. to IGBT, the HCT connection is wrong.


3.Check the HCT connector
1 1 4.If TCD 36 happens even connector perfectly inserted, replace
2 2
3 3 P15
4 4 HCT cable assembly
5 5
6 6 R 85
5.Check the voltage between VBN-14 and GND of DPC-310 as
7 7
8 8 I- CTCHK
9 9 C42
left drawing when TCD 36 happens.(Low (0V) : normal, High(5V) :
10 10
11 11
To HCT로
HCT 12 12 Abnormal)
Connector
컨넥 터 Check
Check 13 13
14 14 In case of abnormal, check if VBN-13 and 14 are shorten.
VBN The shorten condition is normal, replace DPC-310.
DPC- 310
Reactor 6.If TCD 36 happens as soon as IGBT switching even though
리액터 HCT
U
V
above 5 action, replace HCT.
INV STACK
W

DPC-310
DSP - TMS320C3X

VB-3
A/D HCT abnormal when lus, lvs, and lws values
Converter do not change even after switching OPEN.
VB-7
AD7891AS

VBN-11