SERVICE BULLETIN
CONF ALL
AIRBUS
2, ROND POINT EMILE DEWOITINE
31700 BLAGNAC
FRANCE
The content of this document is the property of Airbus. All rights including copyrights are reserved.
It is supplied in confidence and commercial security on its contents must be maintained.
It must not be used for any purpose other than that for which it is supplied, nor may information
contained in it be disclosed to unauthorized persons.
It must not be reproduced in whole or in part without permission in writing from the owners of the
copyright. Requests for reproduction of any data in this document and the media authorized for it must
be addressed to Airbus.
ATA SYSTEM: 46
SUMMARY
APPLICABILITY Operator(s) updated.
SUMMARY
APPLICABILITY Operator(s) updated.
PLANNING INFORMATION
ELECTRICAL LOAD DATA Update of busbar FIN to correct from 206PP to 202PP
without technical impact.
MATERIAL INFORMATION
LIST OF NEW PARTS Keyword of kit 461074A01R02 updated without
technical impact.
CONF 003
SUMMARY
APPLICABILITY Operator(s) updated.
PLANNING INFORMATION
ELECTRICAL LOAD DATA Update of busbar FIN to correct from 206PP to 202PP
without technical impact.
CONF 004
SUMMARY
APPLICABILITY Operator(s) updated.
SUMMARY
APPLICABILITY Operator(s) updated.
PLANNING INFORMATION
ELECTRICAL LOAD DATA Update of busbar FIN to correct from 206PP to 202PP
without technical impact.
MATERIAL INFORMATION
LIST OF NEW PARTS Keyword of kit 461074A01R02 updated without
technical impact.
CONF 006
SUMMARY
APPLICABILITY Operator(s) updated.
PLANNING INFORMATION
ELECTRICAL LOAD DATA Update of busbar FIN to correct from 206PP to 202PP
without technical impact.
MATERIAL INFORMATION
LIST OF NEW PARTS Keyword of kit 461074A01R02 updated without
technical impact.
CONF 007
SUMMARY
APPLICABILITY Operator(s) updated.
PLANNING INFORMATION
ELECTRICAL LOAD DATA Update of busbar FIN to correct from 206PP to 202PP
without technical impact.
MATERIAL INFORMATION
LIST OF NEW PARTS Keyword of kit 461074A01R02 updated without
technical impact.
CONF ALL
D. FILING INSTRUCTIONS
This Service Bulletin has been generated electronically and is reissued as a complete
document. Replace the complete document.
Put this Revision Transmittal Sheet in front of the Service Bulletin.
E. HISTORY OF PREVIOUS REVISIONS
Revision No. 1 issued to add aircraft for operators 43S, ANA, CIB, EIN, GWI, SDM, TAK and
TAR.
Revision No. 02 issued to add aircraft for operators ACA, AHY, AUA, BEL, BER, DLH, IBE, IGO,
KZR, QTR, TCX, THY and VKG.
MODIFICATION CLASSIFICATION
MAJOR 31442P6830
MINOR 153972P13136 36344P9610 38198P9842
NOTE: As per EASA IR 21, a minor change is one that has no appreciable effect on the
mass, balance, structural strength, reliability, operational characteristics affecting
the airworthiness of the product. All other changes are major changes.
CONF 002
MODIFICATION CLASSIFICATION
MAJOR 31442P6830
MINOR 153972P13136 36344P9610 38198P9842
NOTE: As per EASA IR 21, a minor change is one that has no appreciable effect on the
mass, balance, structural strength, reliability, operational characteristics affecting
the airworthiness of the product. All other changes are major changes.
CONF 003
MODIFICATION CLASSIFICATION
MAJOR None
MINOR 153972P13136 38198P9842
NOTE: As per EASA IR 21, a minor change is one that has no appreciable effect on the
mass, balance, structural strength, reliability, operational characteristics affecting
the airworthiness of the product. All other changes are major changes.
CONF 004
MODIFICATION CLASSIFICATION
MAJOR 31442P6830
MINOR 153972P13136 36344P9610 38198P9842
NOTE: As per EASA IR 21, a minor change is one that has no appreciable effect on the
mass, balance, structural strength, reliability, operational characteristics affecting
the airworthiness of the product. All other changes are major changes.
CONF 005
MODIFICATION CLASSIFICATION
MAJOR 31442P6830
MINOR 153972P13136 38198P9842
CONF 006
MODIFICATION CLASSIFICATION
MAJOR 31442P6830
MINOR 153972P13136 36344P9610 38198P9842
NOTE: As per EASA IR 21, a minor change is one that has no appreciable effect on the
mass, balance, structural strength, reliability, operational characteristics affecting
the airworthiness of the product. All other changes are major changes.
CONF 007
MODIFICATION CLASSIFICATION
MAJOR 31442P6830
MINOR 153972P13136 38198P9842
NOTE: As per EASA IR 21, a minor change is one that has no appreciable effect on the
mass, balance, structural strength, reliability, operational characteristics affecting
the airworthiness of the product. All other changes are major changes.
CONF ALL
B. REASON
(1) History
This Service Bulletin is issued further to an operator's request.
(2) Objective/Action
The modification consists in:
- Replacing or installing the two Datalink Control and Display Unit (DCDUs) (FIN
2TX1 and FIN 2TX2).
If the DCDUs were not previously installed, then the modification consists in:
- Removing the safety clips from the DCDU circuit breakers (6TX1 and 6TX2)
- Activating the Air Traffic Control (ATC) message (MSG) Pushbutton Switches (P/
B SW) on the Captain (CAPT) and First Officer (F/O) Glareshield Electrical Panel
131VU and Electrical Panel 130VU (the Inoperative (INOP) placard above each P/
B SW will be removed)
- Activating the DCDU pin programming, modifying the Flight Warning Computer
(FWC) pin programming and adding the Air Traffic Service Unit (ATSU) pin
programming.
(3) Advantages
Accomplishment of this Service Bulletin fulfills the operator's request.
(4) Operational/Maintenance Consequences
None
C. GENERAL EVALUATION
EVALUATION TABLE
COMPLIANCE OPTIONAL COST SAVING NO
A/C OPERATION NO VENDOR SB NO
AFFECTED
CANCELS INSPECTION SB NO ETOPS AFFECTED NO
PAX COMFORT AFFECTED NO POTENTIAL AD NO
RELIABILITY AFFECTED NO STRUCTURAL LIFE EXTENSION NO
LIFE LIMIT NO LINE MAINTENANCE AFFECTED NO
D. MAINTENANCE CONFIGURATION
CONF 001
No specific aircraft maintenance configuration required.
CONF 002
No specific aircraft maintenance configuration required.
CONF 003
No specific aircraft maintenance configuration required.
CONF 004
No specific aircraft maintenance configuration required.
CONF 005
No specific aircraft maintenance configuration required.
CONF 006
No specific aircraft maintenance configuration required.
CONF 007
No specific aircraft maintenance configuration required.
CONF ALL
E. MATERIAL PRICE INFORMATION
CONF 001
(1) Modification
(a) Task set A320-A-46-XX-1074-01000-93AA-A Modification
CONF 002
(1) Modification
CONF 004
(1) Modification
(a) Task set A320-A-46-XX-1074-01000-93AA-A Modification
CONF 005
(1) Modification
CONF 006
(1) Modification
(a) Task set A320-A-46-XX-1074-01000-93AA-A Modification
CONF 007
(1) Modification
(a) Task set A320-A-46-XX-1074-01000-93AA-A Modification
CONF ALL
F. APPLICABILITY
This Service Bulletin is applicable to this (these) operator(s):
10N 11S 14S 15T 17M 33J 36V 39N 39V 43S 46L 46O 48O 52L 82W 83Q 83V 86Z 96O 96U
AAV AAW AAY ABN ACA AEE AHY ALK AMC ART AUA AWC AZA BAW BEL CFG CTN CYF DLH
EDW EIN EWG EZY F2I G8E GAF GMI GTR GWI HDA HFM HST IBE IGO IPM IZG JJP JOC KAC
KNE KZR LDA MMO MSC NVD O2X OTF PGT PLM PVG QAF QQE QTR RWZ SAS SBI SDM SSG
SVA SVR SWR SZN TAP TAR TDR THY UAL VIV VKG VLG VOE
NOTE: This Service Bulletin is written for the operators listed above. The modification in
this Service Bulletin can be done by other operators. If other operators want to do
this modification, use the RFC/RMO procedure and write to:
AIRBUS
2 ROND POINT EMILE DEWOITINE
31700 BLAGNAC
FRANCE
ON A/C 00370, 00390, 00402, 00511, 00520, 00522, 00541, 00553, 00559, 00574, 00577,
00585, 00596, 00603, 00612, 00621, 00635, 00643, 00664, 00673, 00681, 00701, 00703,
00775, 00782, 00815, 00841, 00869, 00880, 00926, 00942, 00947, 00958, 00975, 00987,
00991, 01026, 01144, 01187, 01199
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
ON A/C 01012, 01077, 01084, 01089, 01094, 01136, 01138, 01147, 01152, 01155, 01168,
01170, 01209, 01217, 01226, 01242, 01277, 01394, 01443, 01448, 01457, 01473, 01480,
01484, 01488, 01489, 01560, 01607, 01720, 01722, 01740, 01743, 01745, 01751, 01761,
01762, 01770, 01777, 01779, 01797, 01951, 01963, 02024, 02033, 02057
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
ON A/C 01838
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
ON A/C 02175, 02187, 02191, 02206, 02217, 02250, 02256, 02272, 02278, 02294, 02327,
02364, 02374, 02399, 02409, 02411, 02432, 02486, 02542, 02583, 02607, 02628, 02632,
02635, 03086, 03159, 03169, 03255, 03335, 03377
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
ON A/C 02813, 02833, 02869, 02932, 02976, 02995, 03076, 03079, 03080, 03096, 03115,
03129, 03136, 03138, 03161, 03171, 03178, 03213, 03295, 03318, 03328, 03331, 03343,
03345, 03362, 03412, 03464, 03482, 03501, 03502, 03515, 03532, 03563, 03598, 03609,
03643, 03666, 03695, 03732, 03755, 03781, 03815, 03831, 03846, 03857, 03885, 03906,
03921, 03956, 03976, 03978, 04075, 04081, 04090, 04108, 04119, 04143, 04152, 04195,
04249, 04337, 04364, 04408, 04520, 04523, 04536, 04650
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
ON A/C 01928, 02107, 02113, 02122, 02142, 02156, 02164, 02170, 02184, 02189, 02245,
02279, 02291, 02332, 02341, 02353, 02370, 02382, 02385, 02392, 02395, 02400-02402,
02404, 02414, 02479, 02487, 02516, 02588, 02589, 02602, 02623, 02665, 02700, 02738,
02739, 02763, 02768, 02788, 02810, 02843, 02870, 02897, 02910, 02937, 02966, 03054,
03056, 03068, 03071, 03102, 03142, 03164, 03192, 03227, 03259, 03282, 03308, 03323
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
ON A/C 01171, 02060, 02114, 02121, 02138, 02161, 02168, 02178, 02210, 02223, 02288
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
ON A/C 02452, 02496, 02502, 02522, 02631, 02655, 02685, 02817, 02828, 02846, 02853,
02856, 02865, 02991, 03141, 03224, 03236, 03274, 03369, 03385, 03388, 03397, 03446,
03473, 03484, 03490, 03494, 03519, 03614, 03615, 03636, 03657, 03669, 03866, 03880,
04004, 04203, 04268, 04489, 04521, 05001, 05026, 05167, 05559, 05607, 05877
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
ON A/C 01487
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
ON A/C 01183
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
ON A/C 02157
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
ON A/C 00927
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
ON A/C 00629, 00763, 00764, 00767, 00790, 00833, 00870, 00960, 00979, 01009, 01029,
01042, 01204, 01713
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
CONF ALL
H. NATURE OF THE WORK
CONF 001
AIRCRAFT YES
EQUIPMENT YES
CONF 002
(1) Modification
(a) Task set A320-A-46-XX-1074-01000-93AA-A Modification
AIRCRAFT YES
EQUIPMENT YES
(2) Modification - Additional work 1 no more applicable
(a) Task set A320-A-46-XX-1074-02000-93AA-A Modification - Additional work 1 no
more applicable
AIRCRAFT YES
EQUIPMENT YES
(3) Modification - Additional work 2 for aircraft modified by Revision No. 05 only
or for aircraft which have accomplished Additional Work 1
(a) Task set A320-A-46-XX-1074-03000-93AA-A Modification - Additional work 2 for
aircraft modified by Revision No. 05 only or for aircraft which have accomplished
Additional Work 1
AIRCRAFT YES
EQUIPMENT YES
CONF 003
(1) Modification
(a) Task set A320-A-46-XX-1074-01000-93AA-A Modification
AIRCRAFT YES
EQUIPMENT YES
CONF 004
(1) Modification
(a) Task set A320-A-46-XX-1074-01000-93AA-A Modification
AIRCRAFT YES
EQUIPMENT YES
CONF 005
(1) Modification
(a) Task set A320-A-46-XX-1074-01000-93AA-A Modification
AIRCRAFT YES
EQUIPMENT YES
CONF 006
(1) Modification
AIRCRAFT YES
EQUIPMENT YES
CONF 007
(1) Modification
(a) Task set A320-A-46-XX-1074-01000-93AA-A Modification
AIRCRAFT YES
EQUIPMENT YES
CONF ALL
I. MANPOWER
CONF 001
(1) Modification
(a) Task set A320-A-46-XX-1074-01000-93AA-A Modification
MANPOWER
TOTAL MAN-HOURS 8.50 h
ELAPSED TIME (HOURS) 8.50 h
CONF 002
(1) Modification
(a) Task set A320-A-46-XX-1074-01000-93AA-A Modification
MANPOWER
TOTAL MAN-HOURS 7.50 h
ELAPSED TIME (HOURS) 7.50 h
(2) Modification - Additional work 1 no more applicable
(a) Task set A320-A-46-XX-1074-02000-93AA-A Modification - Additional work 1 no
more applicable
MANPOWER
TOTAL MAN-HOURS 2.50 h
ELAPSED TIME (HOURS) 2.50 h
(3) Modification - Additional work 2 for aircraft modified by Revision No. 05 only
or for aircraft which have accomplished Additional Work 1
(a) Task set A320-A-46-XX-1074-03000-93AA-A Modification - Additional work 2 for
aircraft modified by Revision No. 05 only or for aircraft which have accomplished
Additional Work 1
MANPOWER
TOTAL MAN-HOURS 2.50 h
ELAPSED TIME (HOURS) 2.50 h
CONF 003
(1) Modification
MANPOWER
TOTAL MAN-HOURS 3.00 h
ELAPSED TIME (HOURS) 3.00 h
CONF 004
(1) Modification
(a) Task set A320-A-46-XX-1074-01000-93AA-A Modification
MANPOWER
TOTAL MAN-HOURS 8.50 h
ELAPSED TIME (HOURS) 8.50 h
CONF 005
(1) Modification
(a) Task set A320-A-46-XX-1074-01000-93AA-A Modification
MANPOWER
TOTAL MAN-HOURS 8.50 h
ELAPSED TIME (HOURS) 8.50 h
CONF 006
(1) Modification
(a) Task set A320-A-46-XX-1074-01000-93AA-A Modification
MANPOWER
TOTAL MAN-HOURS 8.50 h
ELAPSED TIME (HOURS) 8.50 h
CONF 007
(1) Modification
(a) Task set A320-A-46-XX-1074-01000-93AA-A Modification
MANPOWER
TOTAL MAN-HOURS 8.50 h
ELAPSED TIME (HOURS) 8.50 h
MODIFICATION OF THE
EQUIPMENT ON LH SIDE CENTER MODIFICATION OF THE
INSTRUMENT PANEL 401VU EQUIPMENT ON RH SIDE CENTER
INSTRUMENT PANEL 400VU
FR24
FR1
ICN-A320-A-46XX1074-A-FAPE3-00HWN-A-003-01
ATA SYSTEM: 46
320-216
ON A/C 00927, 01183, 01349, 01566, 01648, 01749, 01773, 01834, 01862, 01892, 01895,
01902, 01914, 01933, 01957, 01979, 01998, 02097, 02121, 02138, 02156, 02157, 02161,
02164, 02168, 02210, 02223, 02288, 02395, 02401, 02479, 02496, 02502, 02522, 02589,
02602, 02817, 02828, 02856, 03071, 03086, 03141, 03159, 03192, 03227, 03259, 03308,
03335, 03484, 03519, 05877
320-232
ON A/C 00520, 00522, 00541, 00664, 00987, 01144
321-111
ON A/C 00775, 00815, 00841, 00926, 00991, 01012, 01023, 01094, 01607, 01713, 01720,
01881, 01887, 01905, 01921, 01932, 01960, 01972, 02060
321-211
ON A/C 01042, 01080, 01161, 01188, 01199, 01204, 01214, 01260, 01273, 01487, 01928,
02107, 03274, 03369, 03397, 03636, 03669
321-231
CONF ALL
(2) Applicability by MSN
00370 00390 00402 00511 00520 00522 00541 00553 00559 00574 00577 00585
00596 00603 00612 00621 00629 00635 00643 00664 00673 00681 00701 00703
00763 00764 00767 00775 00782 00790 00815 00833 00841 00869 00870 00880
00926 00927 00942 00947 00951 00958 00960 00975 00979 00987 00991 00999
01009 01012 01023 01026 01029 01042 01077 01080 01084 01089 01094 01136
01138 01144 01147 01152 01155 01161 01168 01170-01172 01183 01187 01188
01199 01204 01209 01210 01214 01217 01226 01237 01242 01252 01260 01273
01277 01335 01337 01349 01365 01367 01372 01394 01443 01448 01457 01473
01479 01480 01484 01485 01487-01489 01494 01504 01553 01560 01562 01566
01577 01607 01648 01656 01667 01668 01700 01713 01718 01720 01722 01740
01743 01745 01749 01751 01761 01762 01770 01773 01777 01779 01787 01797
01799 01816 01834 01838 01851 01862 01863 01876 01881 01886 01887 01890
01892 01895 01902 01905 01914 01921 01928 01932 01933 01937 01942 01951
01954 01957 01960 01961 01963 01965 01972 01975 01979 01983 01998 02001
02003 02024 02033 02046 02057 02060 02074 02083 02086 02097 02101 02107
02113 02114 02121 02122 02127 02134 02138 02142 02156 02157 02161 02164
02168 02170 02175 02178 02184 02187 02189 02191 02206 02210 02217 02223
02245 02250 02256 02272 02278 02279 02288 02291 02294 02327 02332 02341
02353 02364 02370 02374 02382 02385 02392 02395 02399-02402 02404 02409
02411 02414 02432 02452 02479 02486 02487 02496 02502 02516 02522 02542
02583 02588 02589 02602 02607 02623 02628 02631 02632 02635 02655 02665
02685 02700 02738 02739 02763 02768 02788 02810 02813 02817 02828 02833
02843 02846 02853 02856 02865 02869 02870 02897 02910 02932 02937 02966
02976 02991 02995 03011 03054 03056 03068 03071 03076 03079 03080 03086
03096 03102 03115 03128 03129 03136 03138 03141 03142 03159 03161 03164
03169 03171 03172 03178 03189 03192 03193 03213 03224 03227 03236 03255
03259 03274 03282 03295 03308 03318 03323 03328 03331 03335 03343 03345
03352 03358 03362 03369 03375 03377 03385 03388 03397 03412 03446 03464
03473 03482 03484 03490 03494 03500-03502 03515 03519 03532 03563 03598
03609 03614 03615 03636 03643 03657 03666 03669 03695 03732 03751 03755
03781 03815 03831 03846 03856 03857 03866 03880 03885 03906 03921 03956
03957 03976 03978 03994 04004 04007 04039 04075 04081 04090 04108 04119
04143 04152 04195 04203 04211 04249 04268 04337 04364 04408 04489 04520
04521 04523 04536 04650 05001 05026 05167 05559 05607 05877
(3) MSN by configuration
CONF 001
MSN CONFIGURATION
00370 00390 00402 00511 00520 00522 00541 00553 00559 001
00574 00577 00585 00596 00603 00612 00621 00635 00643
00664 00673 00681 00701 00703 00764 00767 00782 00833
00869 00880 00926 00942 00947 00958 00960 00975 00979
00987 00991 01009 01012 01023 01026 01029 01042 01077
01080 01084 01089 01094 01136 01144 01147 01152 01155
01161 01170 01171 01172 01183 01187 01188 01199 01204
01209 01210 01214 01237 01242 01252 01260 01273 01277
01337 01349 01365 01367 01372 01394 01443 01479 01484
01487 01488 01494 01504 01553 01560 01566 01607 01648
01656 01667 01668 01700 01713 01718 01720 01743 01749
01751 01761 01762 01773 01777 01787 01797 01799 01816
01834 01851 01862 01863 01876 01881 01886 01887 01890
01892 01895 01902 01905 01914 01921 01928 01932 01933
01937 01942 01951 01954 01957 01960 01961 01963 01965
01972 01975 01979 01983 01998 02001 02003 02024 02060
02097 02107 02113 02114 02121 02122 02134 02138 02142
02156 02157 02161 02164 02168 02170 02175 02178 02184
02187 02189 02191 02206 02210 02217 02223 02245 02250
02256 02272 02278 02279 02288 02291 02294 02327 02332
02341 02353 02364 02370 02374 02382 02385 02392 02395
02399 02400 02401 02402 02404 02409 02411 02414 02432
02452 02479 02486 02487 02496 02502 02516 02522 02542
02583 02588 02589 02602 02607 02623 02628 02631 02632
02635 02655 02665 02685 02700 02738 02739 02763 02768
02788 02810 02813 02817 02828 02833 02843 02846 02853
02856 02865 02869 02870 02897 02910 02932 02937 02966
02976 02991 02995 03054 03056 03068 03071 03076 03079
03080 03086 03096 03102 03115 03129 03136 03138 03141
03142 03159 03161 03164 03169 03171 03178 03189 03192
03213 03224 03227 03236 03255 03259 03274 03282 03295
03308 03318 03323 03328 03331 03335 03343 03345 03362
03369 03377 03385 03388 03397 03412 03446 03464 03473
03482 03484 03490 03494 03501 03502 03515 03519 03532
03563
CONF 002
MSN CONFIGURATION
00629 00763 00775 00790 00815 00841 00870 002
CONF 003
MSN CONFIGURATION
01838 03011 03128 03172 03193 03352 03358 03375 03500 003
CONF 004
MSN CONFIGURATION
03598 03609 03614 03615 03636 03643 03657 03666 03669 004
03695 03732 03755 03781 03815 03831 03846 03857 03866
03880 03885 03906 03921 03956 03976 03978 04004 04075
04081 04090 04108 04119 04143 04152 04195 04203 04249
MSN CONFIGURATION
04268 04337 04364 04408 04489 04520 04521 04523 04536
04650 05001 05026 05167 05559 05607 05877
CONF 005
MSN CONFIGURATION
03751 03856 03957 03994 04007 04039 04211 005
CONF 006
MSN CONFIGURATION
00951 00999 01138 01168 01217 01226 01448 01457 01473 006
01480 01489 01722 01740 01745 01770 01779 02033 02057
02074 02083 02086 02101 02127
CONF 007
MSN CONFIGURATION
00927 01335 01485 01562 01577 02046 007
CONF ALL
(4) Configuration definition
CONF 001
Configuration 001
CONF 001 regards the specific PRE-SB status of the related aircraft.
CONF 001 retrofits following modifications: 153972P13136, 31442P6830,
36344P9610, 38198P9842.
CONF 002
Configuration 002
CONF 002 regards the specific PRE-SB status of the related aircraft.
CONF 002 retrofits following modifications: 153972P13136, 31442P6830,
36344P9610, 38198P9842.
CONF 003
Configuration 003
CONF 003 regards the specific PRE-SB status of the related aircraft.
CONF 003 retrofits following modifications: 153972P13136, 38198P9842.
CONF 004
Configuration 004
CONF 004 regards the specific PRE-SB status of the related aircraft.
CONF 004 retrofits following modifications: 153972P13136, 31442P6830,
36344P9610, 38198P9842.
CONF 005
Configuration 005
CONF 005 regards the specific PRE-SB status of the related aircraft.
CONF 005 retrofits following modifications: 153972P13136, 31442P6830,
38198P9842.
CONF 006
Configuration 006
CONF 006 regards the specific PRE-SB status of the related aircraft.
CONF 006 retrofits following modifications: 153972P13136, 31442P6830,
36344P9610, 38198P9842.
CONF 007
Configuration 007
CONF 007 regards the specific PRE-SB status of the related aircraft.
CONF 007 retrofits following modifications: 153972P13136, 31442P6830,
38198P9842.
CONF ALL
B. CONCURRENT REQUIREMENTS
ON A/C 00370, 00390, 00402, 00511, 00520, 00522, 00541, 00553, 00559, 00574, 00577,
00585, 00596, 00603, 00612, 00621, 00635, 00643, 00664, 00673, 00681, 00701, 00703,
00775, 00782, 00815, 00841, 00869, 00880, 00926, 00942, 00947, 00958, 00975, 00987,
00991, 01026, 01144, 01187, 01199
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
ON A/C 01012, 01077, 01084, 01089, 01094, 01136, 01138, 01147, 01152, 01155, 01168,
01170, 01209, 01217, 01226, 01242, 01277, 01394, 01443, 01448, 01457, 01473, 01480,
01484, 01488, 01489, 01560, 01607, 01720, 01722, 01740, 01743, 01745, 01751, 01761,
01762, 01770, 01777, 01779, 01797, 01951, 01963, 02024, 02033, 02057
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
ON A/C 01838
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
ON A/C 02175, 02187, 02191, 02206, 02217, 02250, 02256, 02272, 02278, 02294, 02327,
02364, 02374, 02399, 02409, 02411, 02432, 02486, 02542, 02583, 02607, 02628, 02632,
02635, 03086, 03159, 03169, 03255, 03335, 03377
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
ON A/C 02813, 02833, 02869, 02932, 02976, 02995, 03076, 03079, 03080, 03096, 03115,
03129, 03136, 03138, 03161, 03171, 03178, 03213, 03295, 03318, 03328, 03331, 03343,
03345, 03362, 03412, 03464, 03482, 03501, 03502, 03515, 03532, 03563, 03598, 03609,
03643, 03666, 03695, 03732, 03755, 03781, 03815, 03831, 03846, 03857, 03885, 03906,
03921, 03956, 03976, 03978, 04075, 04081, 04090, 04108, 04119, 04143, 04152, 04195,
04249, 04337, 04364, 04408, 04520, 04523, 04536, 04650
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
ON A/C 01023
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
ON A/C 01928, 02107, 02113, 02122, 02142, 02156, 02164, 02170, 02184, 02189, 02245,
02279, 02291, 02332, 02341, 02353, 02370, 02382, 02385, 02392, 02395, 02400-02402,
02404, 02414, 02479, 02487, 02516, 02588, 02589, 02602, 02623, 02665, 02700, 02738,
02739, 02763, 02768, 02788, 02810, 02843, 02870, 02897, 02910, 02937, 02966, 03054,
03056, 03068, 03071, 03102, 03142, 03164, 03192, 03227, 03259, 03282, 03308, 03323
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
ON A/C 01171, 02060, 02114, 02121, 02138, 02161, 02168, 02178, 02210, 02223, 02288
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
ON A/C 02452, 02496, 02502, 02522, 02631, 02655, 02685, 02817, 02828, 02846, 02853,
02856, 02865, 02991, 03141, 03224, 03236, 03274, 03369, 03385, 03388, 03397, 03446,
03473, 03484, 03490, 03494, 03519, 03614, 03615, 03636, 03657, 03669, 03866, 03880,
04004, 04203, 04268, 04489, 04521, 05001, 05026, 05167, 05559, 05607, 05877
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
ON A/C 01487
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
ON A/C 01183
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
ON A/C 02157
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
ON A/C 00927
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
ON A/C 00629, 00763, 00764, 00767, 00790, 00833, 00870, 00960, 00979, 01009, 01029,
01042, 01204, 01713
Accomplishment of this Service Bulletin requires the prior or simultaneous accomplishment
of this/these Service Bulletin(s):
CONF ALL
C. REASON
(1) History
This Service Bulletin is issued further to an operator's request.
(2) Objective/Action
The modification consists in:
- Replacing or installing the two Datalink Control and Display Unit (DCDUs) (FIN
2TX1 and FIN 2TX2).
If the DCDUs were not previously installed, then the modification consists in:
- Removing the safety clips from the DCDU circuit breakers (6TX1 and 6TX2)
- Activating the Air Traffic Control (ATC) message (MSG) Pushbutton Switches (P/
B SW) on the Captain (CAPT) and First Officer (F/O) Glareshield Electrical Panel
131VU and Electrical Panel 130VU (the Inoperative (INOP) placard above each P/
B SW will be removed)
- Activating the DCDU pin programming, modifying the Flight Warning Computer
(FWC) pin programming and adding the Air Traffic Service Unit (ATSU) pin
programming.
(3) Advantages
Accomplishment of this Service Bulletin fulfills the operator's request.
(4) Operational/Maintenance Consequences
None
D. DESCRIPTION
To accomplish this Service Bulletin it is necessary to:
(1) Modification
(a) Task set A320-A-46-XX-1074-01000-93AA-A Modification
CONF 001
1 Modify the Equipment and the Wiring in the Cockpit
CONF 002
1 Modify the Equipment in the Cockpit
CONF 003
1 Modify the Equipment in the Cockpit
CONF 004
1 Modify the Equipment and the Wiring in the Cockpit
CONF 005
1 Modify the Equipment and the Wiring in the Cockpit
CONF 006
1 Modify the Equipment and the Wiring in the Cockpit
CONF 007
1 Modify the Equipment and the Wiring in the Cockpit
CONF 001 002 004-007
2 Modify the Equipment in the Rear Circuit Breaker Panel 121VU
3 Modify the Wiring in the Avionics Compartment
CONF 002
(2) Modification - Additional work 1 no more applicable
(1) Classification
OPTIONAL: Service Bulletin for convenience or option.
(2) Accomplishment Timescale
In accordance with operators' maintenance schedule.
F. APPROVAL
The technical content of this document is approved under the authority of Design
Organisation Approval No. EASA.21J.031.
If an aircraft listed in the applicability has a modification or repair embodied that is not
of AIRBUS origin, and which affects the content of this Service Bulletin, the operator
is responsible for obtaining approval by its airworthiness authority for any adaptation
necessary before incorporation of the Service Bulletin.
G. MANPOWER
CONF 001
The manpower estimates given in this Service Bulletin are based on the direct labor cost to
do the work. These estimates assume that the work will be done by experienced personnel,
and may need to be revised upwards to suit operator’s circumstances. The estimates do not
include the time to prepare, plan or inspect the work. Manufacture and procurement of parts
and tools, drying times for paints, sealants, etc., and general administration work are also
not included.
(1) Modification
(a) Task set A320-A-46-XX-1074-01000-93AA-A Modification
PREPARATION
Job Set-up 0.50 h
Parity Configuration Recording 0.50 h
PROCEDURE
Modify the Equipment and the Wiring in the Cockpit 2.00 h
Modify the Equipment in the Rear Circuit Breaker Panel 0.50 h
121VU
Modify the Wiring in the Avionics Compartment 3.00 h
PREPARATION FOR TEST
Job Set-up 0.50 h
TEST
Test 0.50 h
CLOSE-UP
Close-up 1.00 h
TOTAL MAN-HOURS 8.50 h
ELAPSED TIME (HOURS) 8.50 h
CONF 002
The manpower estimates given in this Service Bulletin are based on the direct labor cost to
do the work. These estimates assume that the work will be done by experienced personnel,
and may need to be revised upwards to suit operator’s circumstances. The estimates do not
include the time to prepare, plan or inspect the work. Manufacture and procurement of parts
and tools, drying times for paints, sealants, etc., and general administration work are also
not included.
(1) Modification
(a) Task set A320-A-46-XX-1074-01000-93AA-A Modification
PREPARATION
Job Set-up 0.50 h
Parity Configuration Recording 0.50 h
PROCEDURE
Modify the Equipment in the Cockpit 1.00 h
Modify the Equipment in the Rear Circuit Breaker Panel 0.50 h
121VU
Modify the Wiring in the Avionics Compartment 3.00 h
PREPARATION FOR TEST
Job Set-up 0.50 h
TEST
Test 0.50 h
CLOSE-UP
Close-up 1.00 h
TOTAL MAN-HOURS 7.50 h
ELAPSED TIME (HOURS) 7.50 h
(2) Modification - Additional work 1 no more applicable
(a) Task set A320-A-46-XX-1074-02000-93AA-A Modification - Additional work 1 no
more applicable
PREPARATION
Job Set-up 0.50 h
PROCEDURE
Modify the Equipment and the Wiring in the Cockpit 1.00 h
PREPARATION FOR TEST
Job Set-up 0.25 h
TEST
Test 0.25 h
CLOSE-UP
Close-up 0.50 h
PREPARATION
Job Set-up 0.50 h
PROCEDURE
Modify the Equipment and the Wiring in the Cockpit 1.00 h
PREPARATION FOR TEST
Preparation for Test 0.25 h
TEST
Test 0.25 h
CLOSE-UP
Close-up 0.50 h
TOTAL MAN-HOURS 2.50 h
ELAPSED TIME (HOURS) 2.50 h
CONF 003
The manpower estimates given in this Service Bulletin are based on the direct labor cost to
do the work. These estimates assume that the work will be done by experienced personnel,
and may need to be revised upwards to suit operator’s circumstances. The estimates do not
include the time to prepare, plan or inspect the work. Manufacture and procurement of parts
and tools, drying times for paints, sealants, etc., and general administration work are also
not included.
(1) Modification
(a) Task set A320-A-46-XX-1074-01000-93AA-A Modification
PREPARATION
Job Set-up 0.50 h
PROCEDURE
Modify the Equipment in the Cockpit 1.00 h
PREPARATION FOR TEST
Job Set-up 0.50 h
TEST
Test 0.50 h
CLOSE-UP
Close-up 0.50 h
TOTAL MAN-HOURS 3.00 h
ELAPSED TIME (HOURS) 3.00 h
CONF 004
The manpower estimates given in this Service Bulletin are based on the direct labor cost to
do the work. These estimates assume that the work will be done by experienced personnel,
and may need to be revised upwards to suit operator’s circumstances. The estimates do not
include the time to prepare, plan or inspect the work. Manufacture and procurement of parts
and tools, drying times for paints, sealants, etc., and general administration work are also
not included.
(1) Modification
(a) Task set A320-A-46-XX-1074-01000-93AA-A Modification
PREPARATION
Job Set-up 0.50 h
Parity Configuration Recording 0.50 h
PROCEDURE
Modify the Equipment and the Wiring in the Cockpit 2.00 h
Modify the Equipment in the Rear Circuit Breaker Panel 0.50 h
121VU
Modify the Wiring in the Avionics Compartment 3.00 h
PREPARATION FOR TEST
Job Set-up 0.50 h
TEST
Test 0.50 h
CLOSE-UP
Close-up 1.00 h
TOTAL MAN-HOURS 8.50 h
ELAPSED TIME (HOURS) 8.50 h
CONF 005
The manpower estimates given in this Service Bulletin are based on the direct labor cost to
do the work. These estimates assume that the work will be done by experienced personnel,
and may need to be revised upwards to suit operator’s circumstances. The estimates do not
include the time to prepare, plan or inspect the work. Manufacture and procurement of parts
and tools, drying times for paints, sealants, etc., and general administration work are also
not included.
(1) Modification
(a) Task set A320-A-46-XX-1074-01000-93AA-A Modification
PREPARATION
Job Set-up 0.50 h
Parity Configuration Recording 0.50 h
PROCEDURE
Modify the Equipment and the Wiring in the Cockpit 2.00 h
Modify the Equipment in the Rear Circuit Breaker Panel 0.50 h
121VU
Modify the Wiring in the Avionics Compartment 3.00 h
PREPARATION FOR TEST
Job Set-up 0.50 h
TEST
Test 0.50 h
CLOSE-UP
Close-up 1.00 h
PREPARATION
Job Set-up 0.50 h
Parity Configuration Recording 0.50 h
PROCEDURE
Modify the Equipment and the Wiring in the Cockpit 2.00 h
Modify the Equipment in the Rear Circuit Breaker Panel 0.50 h
121VU
Modify the Wiring in the Avionics Compartment 3.00 h
PREPARATION FOR TEST
Job Set-up 0.50 h
TEST
Test 0.50 h
CLOSE-UP
Close-up 1.00 h
TOTAL MAN-HOURS 8.50 h
ELAPSED TIME (HOURS) 8.50 h
CONF 007
The manpower estimates given in this Service Bulletin are based on the direct labor cost to
do the work. These estimates assume that the work will be done by experienced personnel,
and may need to be revised upwards to suit operator’s circumstances. The estimates do not
include the time to prepare, plan or inspect the work. Manufacture and procurement of parts
and tools, drying times for paints, sealants, etc., and general administration work are also
not included.
(1) Modification
(a) Task set A320-A-46-XX-1074-01000-93AA-A Modification
PREPARATION
Job Set-up 0.50 h
Parity Configuration Recording 0.50 h
PROCEDURE
Modify the Equipment and the Wiring in the Cockpit 2.00 h
Modify the Equipment in the Rear Circuit Breaker Panel 0.50 h
121VU
Modify the Wiring in the Avionics Compartment 3.00 h
ON A/C 00370, 00390, 00402, 00511, 00520, 00522, 00541, 00553, 00559, 00574, 00577,
00585, 00596, 00603, 00612, 00621, 00635, 00643, 00664, 00673, 00681, 00701, 00703,
00775, 00782, 00815, 00841, 00869, 00880, 00926, 00942, 00947, 00958, 00975, 00987,
00991, 01026, 01144, 01187, 01199
ON A/C 01012, 01077, 01084, 01089, 01094, 01136, 01138, 01147, 01152, 01155, 01168,
01170, 01209, 01217, 01226, 01242, 01277, 01394, 01443, 01448, 01457, 01473, 01480,
01484, 01488, 01489, 01560, 01607, 01720, 01722, 01740, 01743, 01745, 01751, 01761,
01762, 01770, 01777, 01779, 01797, 01951, 01963, 02024, 02033, 02057
ON A/C 02157
2. MATERIAL INFORMATION
A. MATERIAL APPLICABILITY
CONF 001
Material for task set A320-A-46-XX-1074-01000-93AA-A Modification
CONF 007
Material for task set A320-A-46-XX-1074-01000-93AA-A Modification
Availability
NOTE(S)
Sales terms must be agreed between the Customer and AIRBUS in accordance with
the RFC (or RFC/RMO) procedure.
Procurement address
NOTE(S)
The AIRBUS material is included in the commercial offer and as such will be supplied
by AIRBUS Upgrade Services. To facilitate the material reception, Airline Customers
are requested to contact:
Procurement address
NOTE(S)
Sales terms must be agreed between the Customer and AIRBUS in accordance with
the RFC (or RFC/RMO) procedure.
Equipment procurement conditions are defined in the commercial offer. For any
assistance, Airline Customers are requested to contact:
Procurement address
NOTE(S)
Sales terms must be agreed between the Customer and AIRBUS in accordance with
the RFC (or RFC/RMO) procedure.
Equipment procurement conditions are defined in the commercial offer. For any
assistance, Airline Customers are requested to contact:
Procurement address
NOTE(S)
Sales terms must be agreed between the Customer and AIRBUS in accordance with
the RFC (or RFC/RMO) procedure.
Equipment procurement conditions are defined in the commercial offer. For any
assistance, Airline Customers are requested to contact:
Procurement address
REV 00 Oct 31/12 A320-46-1074
REV 08 Mar 17/21 Page 53
A318/A319/A320/A321
SERVICE BULLETIN
NOTE(S)
Sales terms must be agreed between the Customer and AIRBUS in accordance with
the RFC (or RFC/RMO) procedure.
Equipment procurement conditions are defined in the commercial offer. For any
assistance, Airline Customers are requested to contact:
Procurement address
NOTE(S)
Sales terms must be agreed between the Customer and AIRBUS in accordance with
the RFC (or RFC/RMO) procedure.
Equipment procurement conditions are defined in the commercial offer. For any
assistance, Airline Customers are requested to contact:
Procurement address
NOTE(S)
Sales terms must be agreed between the Customer and AIRBUS in accordance with
the RFC (or RFC/RMO) procedure.
Equipment procurement conditions are defined in the commercial offer. For any
assistance, Airline Customers are requested to contact:
Procurement address
NOTE(S)
Sales terms must be agreed between the Customer and AIRBUS in accordance with
the RFC (or RFC/RMO) procedure.
Equipment procurement conditions are defined in the commercial offer. For any
assistance, Airline Customers are requested to contact:
DESCRIPTION OLD PART No. NEW PART No. INT SEE NOTES
DCDU-DATALINK
CONTROL AND 401MFD2-1 401MFD3-3 02 (1) (2)
DISPLAY UNIT
NOTE(S)
For definitions of interchangeability codes in column INT. refer to ATA (CSDD Chapter
2).
Only the mixability configuration(s) and condition(s) stated in this Service Bulletin are
approved.
(1): The interchangeability possibilities are for new or modified parts introduced by the
accomplishment of this Service Bulletin.
(2): Mixability is authorized.
Spare parts for task set A320-A-46-XX-1074-01000-93AA-A Modification
CONF ALL
3. ACCOMPLISHMENT INSTRUCTIONS
Task set A320-A-46-XX-1074-01000-93AA-A (A320-A-46-XX-1074-01ZZZ-93AZ-A)
Modification
WARNING: MAKE SURE THAT YOU OBEY ALL THE WARNINGS AND ALL THE CAUTIONS
INCLUDED IN THE REFERENCED PROCEDURES.
NOTE: The accomplishment instructions of this Service Bulletin include procedures given in
other documents or in other sections of the Service Bulletin. When the words “refer to”
are used and the operator has a procedure accepted by the local authority he belongs to,
the accepted alternative procedure can be used. When the words “in accordance with”
are used then the given procedure must be followed.
NOTE: The access and close-up instructions, not comprising return to service tests, in this
Service Bulletin do not constitute or affect the technical intent of the Service Bulletin.
Operators can therefore, as deemed necessary, omit or add access and/or close-up steps
to add flexibility to their maintenance operations as long as the technical intent of the
Service Bulletin is met within the set parameters.
NOTE: Manual titles given in the accomplishment instructions are referred to by acronyms. Refer
to paragraph 1.J., References, for the definition of acronyms.
NOTE: This Service Bulletin contains the instructions for the on-aircraft maintenance necessary
to ensure the continued airworthiness of the aircraft.
For any deviations to the instructions, contact AIRBUS for further instructions and
approval.
CONF 006
TOTAL MAN-HOURS 8.50 h
CONF 007
TOTAL MAN-HOURS 8.50 h
CONF 001
ELAPSED TIME (HOURS) 8.50 h
CONF 002
ELAPSED TIME (HOURS) 7.50 h
CONF 003
ELAPSED TIME (HOURS) 3.00 h
CONF 004
ELAPSED TIME (HOURS) 8.50 h
CONF 005
ELAPSED TIME (HOURS) 8.50 h
CONF 006
ELAPSED TIME (HOURS) 8.50 h
CONF 007
ELAPSED TIME (HOURS) 8.50 h
CONF ALL
B. PREPARATION
CONF 001 002 004-007
(1) Task A320-A-46-XX-1074-01001-540A-A (A320-A-46-XX-1074-01ZZZ-540Z-A)
Job Set-up
Job Set-Up Information
Manpower/Resources/Skills
Man-hours 0.50 h
Minimum Number of person 1
Elapsed Time 0.50 h
Referenced Information
Manuals/Drawings References/Sheets
Task 12-34-24-869-002
Task 22-82-12-000-001
24-50-00, Page Block 001
AMM
Task 25-54-11-000-001
Task 31-53-34-000-001
Task 46-21-34-000-001
A320-28-1080
A320-28-1112
SB
A320-28-1176
A320-28-1185
Procedure
NOTE: For the basic Aircraft configuration, refer to AMM Chapter "Introduction -
Aircraft status for maintenance" in Manual Front Matter section.
(a) Make sure that the aircraft is electrically grounded, refer to Ref. AMM Task 12-34-
24-869-002.
(b) Remove the partition panels (Panel 131CW, Panel 131DW and Panel 132EW) in
the Forward (FWD) cargo compartment for access, refer to Ref. AMM Task 25-54-
11-000-001.
(c) Do the preparation procedure as specified in the removal of the FWCs (FIN
1WW1, FIN 1WW2), refer to Ref. AMM Task 31-53-34-000-001.
(d) Do the preparation procedure as specified in the removal of the ATSU (FIN 1TX1),
refer to Ref. AMM Task 46-21-34-000-001.
(e) Do the preparation procedure as specified in the removal of the Multipurpose
Control and Display Unit (MCDU)s (FIN 3CA1, FIN 3CA2 and, if installed FIN
3CA3), refer to Ref. AMM Task 22-82-12-000-001.
(f) Open, safety/lock and tag this (these) circuit breaker(s):
NOTE: For the circuit breaker location, refer to Ref. AMM 24-50-00, Page Block
001.
NOTE: For aircraft with Additional Center Tank (ACT)6 installed, for access,
remove/install the ACT6 as specified in Service Bulletins No. Ref. SB
A320-28-1112 (FUEL - TANKS - REMOVAL/INSTALLATION OF ADDITIONAL
CENTER TANKS OF OPERATING SEQUENCE B ON A319CJ) or Ref. SB
A320-28-1176 (FUEL - TANKS - FLEXIBILITY TO FIT ZERO TO SIX ACTS
WITH ALTERNATE FUEL SUPPLY SEQUENCE B) or Service Bulletins No.
Ref. SB A320-28-1080 (FUEL - TANKS - REMOVAL/INSTALLATION OF
ADDITIONAL CENTER TANK) or Ref. SB A320-28-1185 (FUEL - TANKS -
FLEXIBILITY TO FIT ZERO TO SIX ACTS WITH ALTERNATE FUEL SUPPLY
SEQUENCE A).
CONF 003
(1) Task A320-A-46-XX-1074-01002-540A-A (A320-A-46-XX-1074-01ZZZ-540Z-A)
Job Set-up
Job Set-Up Information
Manpower/Resources/Skills
Man-hours 0.50 h
Minimum Number of person 1
Elapsed Time 0.50 h
Referenced Information
Manuals/Drawings References/Sheets
Task 12-34-24-869-002
AMM 24-50-00, Page Block 001
Task 46-21-21-000-001
Procedure
NOTE: For the basic Aircraft configuration, refer to AMM Chapter "Introduction -
Aircraft status for maintenance" in Manual Front Matter section.
(a) Make sure that the aircraft is electrically grounded, refer to Ref. AMM Task 12-34-
24-869-002.
(b) Do the preparation procedure as specified in the removal of the DCDUs (FIN
2TX1, FIN 2TX2), refer to Ref. AMM Task 46-21-21-000-001.
(c) Open, safety/lock and tag this (these) circuit breaker(s):
NOTE: For the circuit breaker location, refer to Ref. AMM 24-50-00, Page Block
001.
Man-hours 0.50 h
Minimum Number of person 1
Elapsed Time 0.50 h
Procedure
(a) For the ATSU wiring parity, before any disconnection, record the figure number
of the hook-up chart on which lines 1 and 2 agree with the aircraft wiring
configuration, refer to Ref. Fig. HE and Ref. Fig. HF.
(b) For the FWC-1 (FIN 1WW1) wiring parity, before any disconnection, record the
figure number of the hook-up chart on which lines 1 and 2 agree with the aircraft
wiring configuration, refer to Ref. Fig. HH and Ref. Fig. HI.
(c) For the FWC-2 (FIN 1WW2) wiring parity, before any disconnection, record the
figure number of the hook-up chart on which lines 1 and 2 agree with the aircraft
wiring configuration, refer to Ref. Fig. HJ and Ref. Fig. HK.
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
2 81VU 1813VT 18D EN3155-016M2222 4621-0043 2M CF24 81VU 1TX1-AB 14K M1N
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
2 81VU 1813VT 16D EN3155-016M2222 4621-0043 2M CF24 81VU 1TX1-AB 14K M1N
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
2 85VU 1851VT 59A EN3155-016M2222 3152-0785 1S CF24 85VU 1WW1-AD 10A M1N
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
2 85VU 1851VT 61A EN3155-016M2222 3152-0785 1S CF24 85VU 1WW1-AD 10A M1N
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
2 86VU 1860VT 10A EN3155-016M2222 3152-0772 2S CF24 86VU 1WW2-AD 10A M1N
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
CONF ALL
C. PROCEDURE
CONF 001
(1) Task A320-A-46-XX-1074-01001-920A-A (A320-A-46-XX-1074-01ZZZ-920Z-A)
Modify the Equipment and the Wiring in the Cockpit
Job Set-Up Information
Working Area
Man-hours 2.00 h
Minimum Number of person 1
Elapsed Time 2.00 h
Material necessary to do the job
Part kit 461074A01R02
ITEM PART No. QTY (UM) KEYWORD DRAWING SEE NOTES
D9100095418795 1 PLCRDSET
EN3155-019F2018 6 CONTACT
Components
ITEM PART No. QTY (UM) KEYWORD DRAWING SEE NOTES
2 401MFD3-3 2 DCDU (1)
NOTE(S)
(1): The components listed above are not an AIRBUS Kit, the required parts must be
ordered as necessary through the given channel.
Referenced Information
Manuals/Drawings References/Sheets
Task 11-00-00-400-003
AMM Task 22-82-12-000-001
Task 22-82-12-400-002
20-33-00
20-52-10
ESPM
20-52-21
20-54-50
Procedure
(a) Standard Practices:
1 Tag all the parts you must remove and retain to make the subsequent
installation easier.
2 For the general installation of electrical wire harnesses, refer to Ref. ESPM
20-33-00.
3 Do a check of the electrical connectors before you connect them, refer to
Ref. ESPM 20-52-10.
4 For the protection of the connectors, contacts and terminals, refer to Ref.
ESPM 20-54-50.
5 For the installation of placards, Ref. AMM Task 11-00-00-400-003.
(b) Remove and retain the MCDUs (FIN 3CA1, FIN 3CA2 and if installed FIN 3CA3),
refer to Ref. AMM Task 22-82-12-000-001.
(c) Modify the equipment in the RH and LH Center Instrument Electrical Panel 400VU
and Electrical Panel 401VU.
Refer to Ref. Fig. Modification of the RH and the LH Center Instrument Panels in
400VU and 401VU
1 Remove:
FIN 2TX1
1 DCDU-DATALINK 401MFD3-3 Item 2
CONTROL AND DISPLAY
UNIT
FIN 2TX2
1 DCDU-DATALINK 401MFD3-3 Item 2
CONTROL AND DISPLAY
UNIT
5 Near the DCDUs, bond the placards identified FIN 2TX1 and FIN 2TX2,
supplied in:
6 CONTACT-SOCKET EN3155-019F2018
(f) Do a continuity test of the new and/or modified electrical wires, refer to Ref.
ESPM 20-52-21.
(g) Install the retained MCDUs (FIN 3CA1, FIN 3CA2 and if removed FIN 3CA3), refer
to Ref. AMM Task 22-82-12-400-002.
CONF 001
A B
BEFORE
401VU 400VU
ENGINES
WARNINGS
SYSTEM
PAGES
(1) (1)
A
ICN-A320-A-46XX1074-A-FAPE3-00HW5-A-002-01
CONF 001
AFTER
401VU 400VU
ENGINES
WARNINGS
SYSTEM
PAGES
2 2TX1 2TX2 2
ICN-A320-A-46XX1074-A-FAPE3-00HW6-A-002-01
CONF 001
A B
(3)
INOP
ATC
MSG
01
A
131VU
(3)
INOP
ATC
MSG
B
130VU
NOTE:
01 INSTALLATION OF PUSH BUTTON ATC MSG DEPENDS
ON AIRCRAFT CONFIGURATION.
ICN-A320-A-46XX1074-A-FAPE3-00HW8-A-002-01
CONF 001
BEFORE
A 2
F.R. -
8 R D
F.R.
7348 C
2
9 B L
-
F.R.
K
3CA1 MCDU-1
11VU 1103VT
210 120
F.R.
A
8 R
7349
9 B
3CA3 MCDU-3
101VU
211
A
2M
8 R 19
7350
F.R.
9 B 20
0569 21
3CA2 MCDU-2
11VU A 63VC
210 127
OLD HOOK-UP F.R. FOR REFERENCE EXISTING WIRE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2286
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1M
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-46XX1074-A-FAPE3-00HWO-A-002-01
CONF 001
AFTER
A 2
F.R. -
17 R D
F.R.
7348 C
2
18 B L
-
F.R.
K
3CA1 MCDU-1
11VU 1103VT
210 120
F.R.
A
17 R
7349
18 B
3CA3 MCDU-3
101VU
211
A
2M
17 R 19
7350
F.R.
18 B 20
0569 21
3CA2 MCDU-2
11VU A 63VC
210 127
NEW HOOK-UP F.R. FOR REFERENCE EXISTING WIRE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2286
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1M
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-46XX1074-A-FAPE3-00HWP-A-002-01
CONF 001
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
19
20
21
22
23
24
25
CONF 002
(1) Task A320-A-46-XX-1074-01002-920A-A (A320-A-46-XX-1074-01ZZZ-920Z-A)
Modify the Equipment in the Cockpit
Job Set-Up Information
Working Area
Man-hours 1.00 h
Minimum Number of person 1
Elapsed Time 1.00 h
Material necessary to do the job
Part kit 461074A01R02
ITEM PART No. QTY (UM) KEYWORD DRAWING SEE NOTES
D9100095418795 1 PLCRDSET
Components
ITEM PART No. QTY (UM) KEYWORD DRAWING SEE NOTES
2 401MFD3-3 2 DCDU (1)
NOTE(S)
(1): The components listed above are not an AIRBUS Kit, the required parts must be
ordered as necessary through the given channel.
Referenced Information
Manuals/Drawings References/Sheets
AMM Task 11-00-00-400-003
Procedure
(a) Standard Practices:
1 For the installation of placards, Ref. AMM Task 11-00-00-400-003.
(b) Modify the equipment in the RH and LH Center Instrument Electrical Panel 400VU
and Electrical Panel 401VU.
Refer to Ref. Fig. Modification of the RH and the LH Center Instrument Panels in
400VU and 401VU
1 Remove:
FIN 2TX1
1 DCDU-DATALINK 401MFD3-3 Item 2
CONTROL AND DISPLAY
UNIT
FIN 2TX2
1 DCDU-DATALINK 401MFD3-3 Item 2
CONTROL AND DISPLAY
UNIT
5 Near the DCDUs, bond the placards identified FIN 2TX1 and FIN 2TX2,
supplied in:
CONF 002
A B
BEFORE
401VU 400VU
ENGINES
WARNINGS
SYSTEM
PAGES
(1) (1)
A
ICN-A320-A-46XX1074-A-FAPE3-00HW5-A-002-01
CONF 002
AFTER
401VU 400VU
ENGINES
WARNINGS
SYSTEM
PAGES
2 2TX1 2TX2 2
ICN-A320-A-46XX1074-A-FAPE3-00HW6-A-002-01
CONF 002
A B
(3)
INOP
ATC
MSG
01
A
131VU
(3)
INOP
ATC
MSG
B
130VU
NOTE:
01 INSTALLATION OF PUSH BUTTON ATC MSG DEPENDS
ON AIRCRAFT CONFIGURATION.
ICN-A320-A-46XX1074-A-FAPE3-00HW8-A-002-01
CONF 003
(1) Task A320-A-46-XX-1074-01003-920A-A (A320-A-46-XX-1074-01ZZZ-920Z-A)
Modify the Equipment in the Cockpit
Job Set-Up Information
Working Area
Man-hours 1.00 h
Minimum Number of person 1
Elapsed Time 1.00 h
Material necessary to do the job
Components
ITEM PART No. QTY (UM) KEYWORD DRAWING SEE NOTES
2 401MFD3-3 2 DCDU (1)
NOTE(S)
(1): The components listed above are not an AIRBUS Kit, the required parts must be
ordered as necessary through the given channel.
Referenced Information
Manuals/Drawings References/Sheets
Task 46-21-21-000-001
AMM
Task 46-21-21-400-001
Procedure
(a) Replace the DCDUs.
1 Remove, refer to Ref. AMM Task 46-21-21-000-001.
FIN 2TX1
1 DCDU-DATALINK 401MFD2-1 Item (2)
CONTROL AND DISPLAY
UNIT
FIN 2TX2
1 DCDU-DATALINK 401MFD2-1 Item (2)
CONTROL AND DISPLAY
UNIT
2 Install, refer to Ref. AMM Task 46-21-21-400-001.
FIN 2TX1
1 DCDU-DATALINK 401MFD3-3 Item 2
CONTROL AND DISPLAY
UNIT
FIN 2TX2
1 DCDU-DATALINK 401MFD3-3 Item 2
CONTROL AND DISPLAY
UNIT
REV 00 Oct 31/12 A320-46-1074
REV 08 Mar 17/21 Page 80
A318/A319/A320/A321
SERVICE BULLETIN
CONF 004
(1) Task A320-A-46-XX-1074-01004-920A-A (A320-A-46-XX-1074-01ZZZ-920Z-A)
Modify the Equipment and the Wiring in the Cockpit
Job Set-Up Information
Working Area
Man-hours 2.00 h
Minimum Number of person 1
Elapsed Time 2.00 h
Material necessary to do the job
Part kit 461074A01R02
ITEM PART No. QTY (UM) KEYWORD DRAWING SEE NOTES
D9100095418795 1 PLCRDSET
EN3155-019F2018 6 CONTACT
Components
ITEM PART No. QTY (UM) KEYWORD DRAWING SEE NOTES
2 401MFD3-3 2 DCDU (1)
NOTE(S)
(1): The components listed above are not an AIRBUS Kit, the required parts must be
ordered as necessary through the given channel.
Referenced Information
Manuals/Drawings References/Sheets
Task 11-00-00-400-003
AMM Task 22-82-12-000-001
Task 22-82-12-400-002
20-33-00
20-52-10
ESPM
20-52-21
20-54-50
Procedure
(a) Standard Practices:
1 Tag all the parts you must remove and retain to make the subsequent
installation easier.
2 For the general installation of electrical wire harnesses, refer to Ref. ESPM
20-33-00.
3 Do a check of the electrical connectors before you connect them, refer to
Ref. ESPM 20-52-10.
4 For the protection of the connectors, contacts and terminals, refer to Ref.
ESPM 20-54-50.
FIN 2TX1
1 DCDU-DATALINK 401MFD3-3 Item 2
CONTROL AND DISPLAY
UNIT
FIN 2TX2
1 DCDU-DATALINK 401MFD3-3 Item 2
CONTROL AND DISPLAY
UNIT
5 Near the DCDUs, bond the placards identified FIN 2TX1 and FIN 2TX2,
supplied in:
6 CONTACT-SOCKET EN3155-019F2018
(f) Do a continuity test of the new and/or modified electrical wires, refer to Ref.
ESPM 20-52-21.
(g) Install the retained MCDUs (FIN 3CA1 and FIN 3CA2), refer to Ref. AMM Task 22-
82-12-400-002.
CONF 004
A B
BEFORE
401VU 400VU
ENGINES
WARNINGS
SYSTEM
PAGES
(1) (1)
A
ICN-A320-A-46XX1074-A-FAPE3-00HW5-A-002-01
CONF 004
AFTER
401VU 400VU
ENGINES
WARNINGS
SYSTEM
PAGES
2 2TX1 2TX2 2
ICN-A320-A-46XX1074-A-FAPE3-00HW6-A-002-01
CONF 004
A B
(3)
INOP
ATC
MSG
01
A
131VU
(3)
INOP
ATC
MSG
B
130VU
NOTE:
01 INSTALLATION OF PUSH BUTTON ATC MSG DEPENDS
ON AIRCRAFT CONFIGURATION.
ICN-A320-A-46XX1074-A-FAPE3-00HW8-A-002-01
CONF 004
BEFORE
2
A
-
8 R D
7348 2 F.R.
9 B L
-
F.R.
1103VT
3CA1 MCDU-1 120
210 11VU
2M
A
8 R 19
7350
9 B 20
F.R.
OLD HOOK-UP EXISTING WIRE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2286
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1M
NEW HOOK-UP F.R. FOR REFERENCE SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-46XX1074-A-FAPE3-00HWQ-A-002-01
CONF 004
AFTER
2
A
-
17 R D
7348 2 F.R.
18 B L
-
F.R.
1103VT
3CA1 MCDU-1 120
210 11VU
2M
A
17 R 19
7350
18 B 20
F.R.
OLD HOOK-UP EXISTING WIRE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2286
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1M
NEW HOOK-UP F.R. FOR REFERENCE SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-46XX1074-A-FAPE3-00HWR-A-002-01
CONF 004
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
13
14
15
16
17
18
19
20
21
22
23
24
25
CONF 005
(1) Task A320-A-46-XX-1074-01005-920A-A (A320-A-46-XX-1074-01ZZZ-920Z-A)
Modify the Equipment and the Wiring in the Cockpit
Job Set-Up Information
Working Area
Man-hours 2.00 h
Minimum Number of person 1
Elapsed Time 2.00 h
Material necessary to do the job
Part kit 461074A01R02
ITEM PART No. QTY (UM) KEYWORD DRAWING SEE NOTES
D9100095418795 1 PLCRDSET
EN3155-019F2018 6 CONTACT
Components
ITEM PART No. QTY (UM) KEYWORD DRAWING SEE NOTES
2 401MFD3-3 2 DCDU (1)
NOTE(S)
(1): The components listed above are not an AIRBUS Kit, the required parts must be
ordered as necessary through the given channel.
Referenced Information
Manuals/Drawings References/Sheets
Task 11-00-00-400-003
AMM Task 22-82-12-000-001
Task 22-82-12-400-002
20-33-00
20-52-10
ESPM
20-52-21
20-54-50
Procedure
(a) Standard Practices:
1 Tag all the parts you must remove and retain to make the subsequent
installation easier.
2 For the general installation of electrical wire harnesses, refer to Ref. ESPM
20-33-00.
3 Do a check of the electrical connectors before you connect them, refer to
Ref. ESPM 20-52-10.
4 For the protection of the connectors, contacts and terminals, refer to Ref.
ESPM 20-54-50.
FIN 2TX1
1 DCDU-DATALINK 401MFD3-3 Item 2
CONTROL AND DISPLAY
UNIT
FIN 2TX2
1 DCDU-DATALINK 401MFD3-3 Item 2
CONTROL AND DISPLAY
UNIT
5 Near the DCDUs, bond the placards identified FIN 2TX1 and FIN 2TX2,
supplied in:
6 CONTACT-SOCKET EN3155-019F2018
(f) Do a continuity test of the new and/or modified electrical wires, refer to Ref.
ESPM 20-52-21.
(g) Install the retained MCDUs (FIN 3CA1 and FIN 3CA2), refer to Ref. AMM Task 22-
82-12-400-002.
CONF 005
A B
BEFORE
401VU 400VU
ENGINES
WARNINGS
SYSTEM
PAGES
(1) (1)
A
ICN-A320-A-46XX1074-A-FAPE3-00HW5-A-002-01
CONF 005
AFTER
401VU 400VU
ENGINES
WARNINGS
SYSTEM
PAGES
2 2TX1 2TX2 2
ICN-A320-A-46XX1074-A-FAPE3-00HW6-A-002-01
CONF 005
A B
(3)
INOP
ATC
MSG
01
A
131VU
(3)
INOP
ATC
MSG
B
130VU
NOTE:
01 INSTALLATION OF PUSH BUTTON ATC MSG DEPENDS
ON AIRCRAFT CONFIGURATION.
ICN-A320-A-46XX1074-A-FAPE3-00HW8-A-002-01
CONF 005
BEFORE
2
A
-
8 R D
7348 2 F.R.
9 B L
-
F.R.
1103VT
3CA1 MCDU-1 120
210 11VU
2M
A
8 R 19
7350
9 B 20
F.R.
OLD HOOK-UP EXISTING WIRE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2286
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1M
NEW HOOK-UP F.R. FOR REFERENCE SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-46XX1074-A-FAPE3-00HWQ-A-002-01
CONF 005
AFTER
2
A
-
17 R D
7348 2 F.R.
18 B L
-
F.R.
1103VT
3CA1 MCDU-1 120
210 11VU
2M
A
17 R 19
7350
18 B 20
F.R.
OLD HOOK-UP EXISTING WIRE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2286
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1M
NEW HOOK-UP F.R. FOR REFERENCE SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-46XX1074-A-FAPE3-00HWR-A-002-01
CONF 005
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
13
14
15
16
17
18
19
20
21
22
23
24
25
CONF 006
(1) Task A320-A-46-XX-1074-01006-920A-A (A320-A-46-XX-1074-01ZZZ-920Z-A)
Modify the Equipment and the Wiring in the Cockpit
Job Set-Up Information
Working Area
Man-hours 2.00 h
Minimum Number of person 1
Elapsed Time 2.00 h
Material necessary to do the job
Part kit 461074A01R02
ITEM PART No. QTY (UM) KEYWORD DRAWING SEE NOTES
D9100095418795 1 PLCRDSET
EN3155-019F2018 6 CONTACT
Components
ITEM PART No. QTY (UM) KEYWORD DRAWING SEE NOTES
2 401MFD3-3 2 DCDU (1)
NOTE(S)
(1): The components listed above are not an AIRBUS Kit, the required parts must be
ordered as necessary through the given channel.
Referenced Information
Manuals/Drawings References/Sheets
Task 11-00-00-400-003
AMM Task 22-82-12-000-001
Task 22-82-12-400-002
20-33-00
20-52-10
ESPM
20-52-21
20-54-50
Procedure
(a) Standard Practices:
1 Tag all the parts you must remove and retain to make the subsequent
installation easier.
2 For the general installation of electrical wire harnesses, refer to Ref. ESPM
20-33-00.
3 Do a check of the electrical connectors before you connect them, refer to
Ref. ESPM 20-52-10.
4 For the protection of the connectors, contacts and terminals, refer to Ref.
ESPM 20-54-50.
FIN 2TX1
1 DCDU-DATALINK 401MFD3-3 Item 2
CONTROL AND DISPLAY
UNIT
FIN 2TX2
1 DCDU-DATALINK 401MFD3-3 Item 2
CONTROL AND DISPLAY
UNIT
5 Near the DCDUs, bond the placards identified FIN 2TX1 and FIN 2TX2,
supplied in:
6 CONTACT-SOCKET EN3155-019F2018
(f) Do a continuity test of the new and/or modified electrical wires, refer to Ref.
ESPM 20-52-21.
(g) Install the retained MCDUs (FIN 3CA1, FIN 3CA2 and if removed FIN 3CA3), refer
to Ref. AMM Task 22-82-12-400-002.
CONF 006
A B
BEFORE
401VU 400VU
ENGINES
WARNINGS
SYSTEM
PAGES
(1) (1)
A
ICN-A320-A-46XX1074-A-FAPE3-00HW5-A-002-01
CONF 006
AFTER
401VU 400VU
ENGINES
WARNINGS
SYSTEM
PAGES
2 2TX1 2TX2 2
ICN-A320-A-46XX1074-A-FAPE3-00HW6-A-002-01
CONF 006
A B
(3)
INOP
ATC
MSG
01
A
131VU
(3)
INOP
ATC
MSG
B
130VU
NOTE:
01 INSTALLATION OF PUSH BUTTON ATC MSG DEPENDS
ON AIRCRAFT CONFIGURATION.
ICN-A320-A-46XX1074-A-FAPE3-00HW8-A-002-01
CONF 006
BEFORE
A 2
F.R. -
8 R D
F.R.
7348 C
2
9 B L
-
F.R.
K
3CA1 MCDU-1
11VU 1103VT
210 120
F.R.
A
8 R
7349
9 B
3CA3 MCDU-3
101VU
211
A
2M
8 R 19
7350
F.R.
9 B 20
0569 21
3CA2 MCDU-2
11VU A 63VC
210 127
OLD HOOK-UP F.R. FOR REFERENCE EXISTING WIRE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2286
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1M
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-46XX1074-A-FAPE3-00HWO-A-002-01
CONF 006
AFTER
A 2
F.R. -
17 R D
F.R.
7348 C
2
18 B L
-
F.R.
K
3CA1 MCDU-1
11VU 1103VT
210 120
F.R.
A
17 R
7349
18 B
3CA3 MCDU-3
101VU
211
A
2M
17 R 19
7350
F.R.
18 B 20
0569 21
3CA2 MCDU-2
11VU A 63VC
210 127
NEW HOOK-UP F.R. FOR REFERENCE EXISTING WIRE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2286
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1M
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-46XX1074-A-FAPE3-00HWP-A-002-01
CONF 006
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
19
20
21
22
23
24
25
CONF 007
(1) Task A320-A-46-XX-1074-01007-920A-A (A320-A-46-XX-1074-01ZZZ-920Z-A)
Modify the Equipment and the Wiring in the Cockpit
Job Set-Up Information
Working Area
Man-hours 2.00 h
Minimum Number of person 1
Elapsed Time 2.00 h
Material necessary to do the job
Part kit 461074A01R02
ITEM PART No. QTY (UM) KEYWORD DRAWING SEE NOTES
D9100095418795 1 PLCRDSET
EN3155-019F2018 6 CONTACT
Components
ITEM PART No. QTY (UM) KEYWORD DRAWING SEE NOTES
2 401MFD3-3 2 DCDU (1)
NOTE(S)
(1): The components listed above are not an AIRBUS Kit, the required parts must be
ordered as necessary through the given channel.
Referenced Information
Manuals/Drawings References/Sheets
Task 11-00-00-400-003
AMM Task 22-82-12-000-001
Task 22-82-12-400-002
20-33-00
20-52-10
ESPM
20-52-21
20-54-50
Procedure
(a) Standard Practices:
1 Tag all the parts you must remove and retain to make the subsequent
installation easier.
2 For the general installation of electrical wire harnesses, refer to Ref. ESPM
20-33-00.
3 Do a check of the electrical connectors before you connect them, refer to
Ref. ESPM 20-52-10.
4 For the protection of the connectors, contacts and terminals, refer to Ref.
ESPM 20-54-50.
FIN 2TX1
1 DCDU-DATALINK 401MFD3-3 Item 2
CONTROL AND DISPLAY
UNIT
FIN 2TX2
1 DCDU-DATALINK 401MFD3-3 Item 2
CONTROL AND DISPLAY
UNIT
5 Near the DCDUs, bond the placards identified FIN 2TX1 and FIN 2TX2,
supplied in:
6 CONTACT-SOCKET EN3155-019F2018
(f) Do a continuity test of the new and/or modified electrical wires, refer to Ref.
ESPM 20-52-21.
(g) Install the retained MCDUs (FIN 3CA1, FIN 3CA2 and if removed FIN 3CA3), refer
to Ref. AMM Task 22-82-12-400-002.
CONF 007
A B
BEFORE
401VU 400VU
ENGINES
WARNINGS
SYSTEM
PAGES
(1) (1)
A
ICN-A320-A-46XX1074-A-FAPE3-00HW5-A-002-01
CONF 007
AFTER
401VU 400VU
ENGINES
WARNINGS
SYSTEM
PAGES
2 2TX1 2TX2 2
ICN-A320-A-46XX1074-A-FAPE3-00HW6-A-002-01
CONF 007
A B
(3)
INOP
ATC
MSG
01
A
131VU
(3)
INOP
ATC
MSG
B
130VU
NOTE:
01 INSTALLATION OF PUSH BUTTON ATC MSG DEPENDS
ON AIRCRAFT CONFIGURATION.
ICN-A320-A-46XX1074-A-FAPE3-00HW8-A-002-01
CONF 007
BEFORE
A 2
F.R. -
8 R D
F.R.
7348 C
2
9 B L
-
F.R.
K
3CA1 MCDU-1
11VU 1103VT
210 120
F.R.
A
8 R
7349
9 B
3CA3 MCDU-3
101VU
211
A
2M
8 R 19
7350
F.R.
9 B 20
0569 21
3CA2 MCDU-2
11VU A 63VC
210 127
OLD HOOK-UP F.R. FOR REFERENCE EXISTING WIRE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2286
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1M
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-46XX1074-A-FAPE3-00HWO-A-002-01
CONF 007
AFTER
A 2
F.R. -
17 R D
F.R.
7348 C
2
18 B L
-
F.R.
K
3CA1 MCDU-1
11VU 1103VT
210 120
F.R.
A
17 R
7349
18 B
3CA3 MCDU-3
101VU
211
A
2M
17 R 19
7350
F.R.
18 B 20
0569 21
3CA2 MCDU-2
11VU A 63VC
210 127
NEW HOOK-UP F.R. FOR REFERENCE EXISTING WIRE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2286
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1M
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-46XX1074-A-FAPE3-00HWP-A-002-01
CONF 007
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
19
20
21
22
23
24
25
Man-hours 0.50 h
Minimum Number of person 1
Elapsed Time 0.50 h
Referenced Information
Manuals/Drawings References/Sheets
AMM Task 20-16-00-912-001
Procedure
(a) Standard Practices:
1 For circuit breaker safety practices, refer to Ref. AMM Task 20-16-00-912-
001.
(b) Modify the equipment in the Circuit Breaker Electrical Panel 121VU.
Refer to Ref. Fig. Modification of the Equipment in the Cockpit
1 At the position 17L, remove:
Z210
FR12
FR1
DC A
DU
1 120VU
DC (4)
DU
2
1
2
C
D
6TX1
16
17 C
18 (4)
B 19
121VU 20
21
6TX2
ICN-A320-A-46XX1074-A-FAPE3-00HW7-A-002-01
Man-hours 3.00 h
Minimum Number of person 1
Elapsed Time 3.00 h
Material necessary to do the job
Part kit 461074A01R02
ITEM PART No. QTY (UM) KEYWORD DRAWING SEE NOTES
E0170FA2200 4 CONTACT
EN3155-016M2222 8 CONTACT
Referenced Information
Manuals/Drawings References/Sheets
Task 31-53-34-000-001
Task 31-53-34-400-001
AMM
Task 46-21-34-000-001
Task 46-21-34-400-001
20-33-00
20-52-10
ESPM
20-52-21
20-54-50
Procedure
(a) Standard Practices:
1 Tag all the parts you must remove and retain to make the subsequent
installation easier.
2 For the general installation of electrical wire harnesses, refer to Ref. ESPM
20-33-00.
3 Do a check of the electrical connectors before you connect them, refer to
Ref. ESPM 20-52-10.
4 For the protection of the connectors, contacts and terminals, refer to Ref.
ESPM 20-54-50.
(b) Remove and retain the ATSU (FIN 1TX1), refer to Ref. AMM Task 46-21-34-000-
001.
(c) Remove and retain the FWCs (FIN 1WW1, FIN 1WW2), refer to Ref. AMM Task 31-
53-34-000-001.
(d) Modify the DCDU pin programming in the Shelves Electrical Panel 81VU and
Electrical Panel 82VU.
4 CONTACT EN3155-016M2222
(e) Modify the ATSU pin programming on the Shelf Electrical Panel 81VU.
1 Modify the connection of the wire(s) as shown on this(these) wiring
diagram(s) and the related hook-up chart(s):
- Ref. Fig. WD and Ref. Fig. HD.
If necessary, use:
1 CONTACT EN3155-016M2222
2 Modify the ATSU wiring parity:
a If during accomplishment of paragraph Ref. Task A320-A-46-XX-
1074-02ZZZ-540Z-A, you recorded that the existing aircraft wiring
corresponded to lines 1 and 2 of Ref. Fig. HE:
<1> Modify the connection of the wire(s) as shown on this(these)
wiring diagram(s) and the related hook-up chart(s):
- Ref. Fig. WE and Ref. Fig. HE.
If necessary, use:
1 CONTACT EN3155-016M2222
b If during accomplishment of paragraph Ref. Task A320-A-46-XX-
1074-02ZZZ-540Z-A, you recorded that the existing aircraft wiring
corresponded to lines 1 and 2 of Ref. Fig. HF:
<1> Modify the connection of the wire(s) as shown on this(these)
wiring diagram(s) and the related hook-up chart(s):
- Ref. Fig. WF and Ref. Fig. HF.
If necessary, use:
1 CONTACT EN3155-016M2222
(f) Modify the FWC wiring on the Shelves Electrical Panel 85VU and Electrical Panel
86VU.
1 Modify the connection of the wire(s) as shown on this(these) wiring
diagram(s) and the related hook-up chart(s):
- Ref. Fig. WC and Ref. Fig. HC.
If necessary, use:
4 CONTACT-SOCKET E0170FA2200
(g) Modify the FWCs (FIN 1WW1, FIN 1WW2) pin programming on the Shelves
Electrical Panel 85VU and Electrical Panel 86VU.
1 Modify the connection of the wire(s) as shown on this(these) wiring
diagram(s) and the related hook-up chart(s):
- Ref. Fig. WG and Ref. Fig. HG.
2 Modify the parity of the FWC (FIN 1WW1):
1 CONTACT EN3155-016M2222
b If during accomplishment of paragraph Ref. Task A320-A-46-XX-
1074-02ZZZ-540Z-A, you recorded that the existing aircraft wiring
corresponded to lines 1 and 2 of Ref. Fig. HI:
<1> Modify the connection of the wire(s) as shown on this(these)
wiring diagram(s) and the related hook-up chart(s):
- Ref. Fig. WI and Ref. Fig. HI.
If necessary, use:
1 CONTACT EN3155-016M2222
3 Modify the parity of the FWC (FIN 1WW2):
a If during accomplishment of paragraph Ref. Task A320-A-46-XX-
1074-02ZZZ-540Z-A, you recorded that the existing aircraft wiring
corresponded to lines 1 and 2 of Ref. Fig. HJ:
<1> Modify the connection of the wire(s) as shown on this(these)
wiring diagram(s) and the related hook-up chart(s):
- Ref. Fig. WJ and Ref. Fig. HJ.
If necessary, use:
1 CONTACT EN3155-016M2222
b If during accomplishment of paragraph Ref. Task A320-A-46-XX-
1074-02ZZZ-540Z-A, you recorded that the existing aircraft wiring
corresponded to lines 1 and 2 of Ref. Fig. HK:
<1> Modify the connection of the wire(s) as shown on this(these)
wiring diagram(s) and the related hook-up chart(s):
- Ref. Fig. WK and Ref. Fig. HK.
If necessary, use:
1 CONTACT EN3155-016M2222
(h) Do a continuity test of the new and/or modified electrical wires, refer to Ref.
ESPM 20-52-21.
(i) Install the retained ATSU (FIN 1TX1), refer to Ref. AMM Task 46-21-34-400-001.
(j) Install the retained FWCs (FIN 1WW1, FIN 1WW2), refer to Ref. AMM Task 31-53-
34-400-001.
BEFORE
27
E
F.R. 54 0133 F
1813VT
A 41VC 127
127 81VU
2M
2
C
68 0122 D
E
F.R. 69 0123 F
K
72 0126 L
A 110VC 1822VT
128 128
82VU
OLD HOOK-UP F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 4621
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE CF24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1M
ICN-A320-A-46XX1074-A-FAPE3-00HWS-A-002-01
AFTER
23
F.R. 54 0133 F
- F.R.
A 41VC B1
127 1813VT
127
81VU
2M
68 0122
5
F.R. D
69 0123 F
L
72 0126 - F.R.
A 110VC B2
128 1822VT
128
82VU
NEW HOOK-UP F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 4621
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE CF24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1M
ICN-A320-A-46XX1074-A-FAPE3-00HWT-A-003-01
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
BEFORE
AB 17
15B 0033 C
1813VT
1TX1 ATSU-1 127
127 81VU 81VU
AFTER
AB 18
15B 0033 C
- F.R.
1813VT
1TX1 ATSU-1 127
127 81VU 81VU
OLD HOOK-UP NEW HOOK-UP F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 4621
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE CF24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2M
ICN-A320-A-46XX1074-A-FAPE3-00HWW-A-003-01
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
2 81VU 1813VT 18C EN3155-016M2222 4621-0033 2M CF24 81VU 1TX1-AB 15B M1N
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
2 81VU 1813VT 18D EN3155-016M2222 4621-0043 2M CF24 81VU 1TX1-AB 14K M1N
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
BEFORE
AB 16
14K 0043 D
1813VT
1TX1 ATSU-1 127
127 81VU 81VU
AFTER
AB 18
14K 0043 D
- F.R.
1813VT
1TX1 ATSU-1 127
127 81VU 81VU
OLD HOOK-UP NEW HOOK-UP F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 4621
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE CF24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2M
ICN-A320-A-46XX1074-A-FAPE3-00HWX-A-002-01
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
2 81VU 1813VT 16D EN3155-016M2222 4621-0043 2M CF24 81VU 1TX1-AB 14K M1N
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
BEFORE
AB 18
14K 0043 D
- F.R.
1813VT
1TX1 ATSU-1 127
127 81VU 81VU
AFTER
AB 16
14K 0043 D
1813VT
1TX1 ATSU-1 127
127 81VU 81VU
OLD HOOK-UP NEW HOOK-UP F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 4621
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE CF24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2M
ICN-A320-A-46XX1074-A-FAPE3-00HWY-A-002-01
BEFORE
AE 25
1C 0169 R
-
AB 32 F.R.
1J 0170 G
-
1WW2 FWC-2 2M 1862VT
86VU
128
AE 73
1C 0173 C
-
AB 73 F.R.
1J 0174 S
-
1WW1 FWC-1 1853VT
85VU
127
OLD HOOK-UP STOWED WIRE F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 4621
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE CF24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1M
ICN-A320-A-46XX1074-A-FAPE3-00HWU-A-002-01
AFTER
AE 25
1C 0169 R
-
AB 32 F.R.
1J 0170 G
-
1WW2 FWC-2 2M 1862VT
86VU
128
AE 73
1C 0173 C
-
AB 73 F.R.
1J 0174 S
-
1WW1 FWC-1 1853VT
85VU
127
NEW HOOK-UP F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 4621
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE CF24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1M
ICN-A320-A-46XX1074-A-FAPE3-00HWV-A-002-01
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
BEFORE
AA
63
10C 0870 A
1851VT
127
85VU
1WW1 FWC-1
127 85VU
AA
2S
11
10C 0861 A
1860VT
128
86VU
1WW2 FWC-2
128 86VU
OLD HOOK-UP NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3152
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE CF24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1S
ICN-A320-A-46XX1074-A-FAPE3-00HWZ-A-002-01
AFTER
AA
62
10C 0870 A
F.R.
DC1
1851VT
127
85VU
1WW1 FWC-1
127 85VU
AA
2S
12
10C 0861 A
F.R.
DC2
1860VT
128
86VU
1WW2 FWC-2
128 86VU
NEW HOOK-UP F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3152
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE CF24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1S
ICN-A320-A-46XX1074-A-FAPE3-00HX0-A-002-01
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
2 85VU 1851VT 62A EN3155-016M2222 3152-0870 1S CF24 85VU 1WW1-AA 10C M1N
4 86VU 1860VT 12A EN3155-016M2222 3152-0861 2S CF24 86VU 1WW2-AA 10C M1N
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
2 85VU 1851VT 59A EN3155-016M2222 3152-0785 1S CF24 85VU 1WW1-AD 10A M1N
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
BEFORE
AD
61
10A 0785 A
1851VT
127
85VU
1WW1 FWC-1
127 85VU
AFTER
AD
59
10A 0785 A
F.R.
DC1
1851VT
127
85VU
1WW1 FWC-1
127 85VU
OLD HOOK-UP NEW HOOK-UP F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3152
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE CF24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1S
ICN-A320-A-46XX1074-A-FAPE3-00HX1-A-002-01
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
2 85VU 1851VT 61A EN3155-016M2222 3152-0785 1S CF24 85VU 1WW1-AD 10A M1N
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
BEFORE
AD
59
10A 0785 A
F.R.
DC1
1851VT
127
85VU
1WW1 FWC-1
127 85VU
AFTER
AD
61
10A 0785 A
1851VT
127
85VU
1WW1 FWC-1
127 85VU
OLD HOOK-UP NEW HOOK-UP F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3152
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE CF24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1S
ICN-A320-A-46XX1074-A-FAPE3-00HX2-A-002-01
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
BEFORE
AD
10
10A 0772 A
1860VT
128
86VU
1WW2 FWC-2
128 86VU
AFTER
AD
8
10A 0772 A
F.R.
DC2
1860VT
128
86VU
1WW2 FWC-2
128 86VU
OLD HOOK-UP NEW HOOK-UP F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3152
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE CF24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2S
ICN-A320-A-46XX1074-A-FAPE3-00HX3-A-002-01
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
2 86VU 1860VT 10A EN3155-016M2222 3152-0772 2S CF24 86VU 1WW2-AD 10A M1N
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
BEFORE
AD
8
10A 0772 A
F.R.
DC2
1860VT
128
86VU
1WW2 FWC-2
128 86VU
AFTER
AD
10
10A 0772 A
1860VT
128
86VU
1WW2 FWC-2
128 86VU
OLD HOOK-UP NEW HOOK-UP F.R. FOR REFERENCE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 3152
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE CF24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 2S
ICN-A320-A-46XX1074-A-FAPE3-00HX4-A-002-01
CONF ALL
D. PREPARATION FOR TEST
(1) Task A320-A-46-XX-1074-08001-540A-A (A320-A-46-XX-1074-08ZZZ-540Z-A)
Job Set-up
Job Set-Up Information
Manpower/Resources/Skills
Man-hours 0.50 h
Minimum Number of person 1
Elapsed Time 0.50 h
Referenced Information
Manuals/Drawings References/Sheets
Task 20-16-00-912-001
AMM
24-50-00, Page Block 001
Procedure
(a) Standard Practices:
1 For circuit breaker safety practices, refer to Ref. AMM Task 20-16-00-912-
001.
(b) Remove the safety clip(s) and/or tag(s) and close/unlock this (these) circuit
breaker(s):
NOTE: For the circuit breaker location, refer to Ref. AMM 24-50-00, Page Block
001.
E. TEST
(1) Task A320-A-46-XX-1074-01001-390A-A (A320-A-46-XX-1074-01ZZZ-390Z-A)
Test
Job Set-Up Information
Manpower/Resources/Skills
Man-hours 0.50 h
Minimum Number of person 1
Elapsed Time 0.50 h
Referenced Information
Manuals/Drawings References/Sheets
Task 24-41-00-861-002
Task 24-41-00-862-002
24-50-00, Page Block 001
AMM
Task 31-32-00-860-013
Task 31-60-00-860-001
Task 31-60-00-860-002
Manuals/Drawings References/Sheets
Task 46-21-00-740-001
Procedure
(a) Do the Built-In Test Equipment (BITE) test of the Air Traffic and Information
Management System (ATIMS), refer to Ref. AMM Task 46-21-00-740-001.
NOTE: If the SB reference is not specified in the latest operator's AMM issue, do
these steps:
1 Job Set-up:
a Energize the aircraft electrical circuits, refer to Ref. AMM Task 24-41-
00-861-002.
b Aircraft Maintenance Configuration
<1> Do the Electronic Instrument System (EIS) start procedure, refer
to Ref. AMM Task 31-60-00-860-001.
<2> Do the procedure to get the SYSTEM REPORT/TEST/INFO SYS
page, refer to Ref. AMM Task 31-32-00-860-013.
c Make sure that this(these) circuit breaker(s) is(are) closed:
NOTE: For the circuit breaker location, refer to Ref. AMM 24-50-00,
Page Block 001.
2 Procedure:
a BITE Test of the ATIMS:
<1> During the test, obey the instructions on the MCDU
ACTION RESULT
1. On the MCDU 1: On the MCDU 1:
- push the line key adjacent to - the ATIMS page comes into view.
the ATIMS indication.
2. On the MCDU 1: On the MCDU 1:
ACTION RESULT
- push the line key adjacent to - the TEST IN PROGRESS indication comes into
the SYSTEM TEST indication. view.
On the upper Electronic Centralized Aircraft
Monitoring (ECAM) Display Unit (DU):
- push the line key adjacent to - the second test screen (Black/White) comes
the applicable answer (LSK 4L, into view.
5L, 4R or 5R).
On the MCDU 1:
- push the line key adjacent to - the third test screen (White/Black) comes
the applicable answer (LSK 4L, into view.
5L, 4R or 5R).
On the MCDU 1:
ACTION RESULT
- push the line key adjacent to
the applicable answer (LSK 4L,
5L, 4R or 5R).
On the MCDU 1:
Man-hours 1.00 h
Minimum Number of person 1
Elapsed Time 1.00 h
Referenced Information
Manuals/Drawings References/Sheets
Task 22-82-12-400-002
Task 24-41-00-862-002
AMM Task 25-54-11-400-001
Task 31-53-34-400-001
Task 46-21-34-400-001
Procedure
(a) Make sure that the work areas are clean and clear of tools and other items of
equipment.
(b) De-energize the aircraft electrical circuits, refer to Ref. AMM Task 24-41-00-862-
002.
(c) Do the close-up procedure as specified in the installation of the FWCs (FIN
1WW1, FIN 1WW2), refer to Ref. AMM Task 31-53-34-400-001.
(d) Do the close-up procedure as specified in the installation of the ATSU (FIN 1TX1),
refer to Ref. AMM Task 46-21-34-400-001.
(e) Do the close-up procedure as specified in the installation of the MCDUs (FIN
3CA1, FIN 3CA2 and, if installed FIN 3CA3), refer to Ref. AMM Task 22-82-12-400-
002.
(f) Install the partition panels (Panel 131CW, Panel 131DW and Panel 132EW) in the
FWD cargo compartment, refer to Ref. AMM Task 25-54-11-400-001.
(g) Put the aircraft back to its initial configuration.
CONF 003
(1) Task A320-A-46-XX-1074-01002-740A-A (A320-A-46-XX-1074-01ZZZ-740Z-A)
Close-up
Job Set-Up Information
Manpower/Resources/Skills
Man-hours 0.50 h
Minimum Number of person 1
Elapsed Time 0.50 h
Referenced Information
Manuals/Drawings References/Sheets
Task 24-41-00-862-002
AMM
Task 46-21-21-400-001
Procedure
(a) Make sure that the work areas are clean and clear of tools and other items of
equipment.
(b) De-energize the aircraft electrical circuits, refer to Ref. AMM Task 24-41-00-862-
002.
(c) Do the close-up procedure as specified in the installation of the DCDUs (FIN
2TX1, FIN 2TX2), refer to Ref. AMM Task 46-21-21-400-001.
(d) Put the aircraft back to its initial configuration.
CONF ALL
G. ADMINISTRATIVE
(1) Task A320-A-46-XX-1074-01001-90AA-A (A320-A-46-XX-1074-01ZZZ-90AZ-A)
Administrative
Procedure
Confirm in the applicable aircraft records that you have completed all the work defined
in this Service Bulletin task set as required.
CONF 002
Task set A320-A-46-XX-1074-02000-93AA-A (A320-A-46-XX-1074-02ZZZ-93AZ-A)
Modification - Additional work 1 no more applicable
WARNING: MAKE SURE THAT YOU OBEY ALL THE WARNINGS AND ALL THE CAUTIONS
INCLUDED IN THE REFERENCED PROCEDURES.
NOTE: The accomplishment instructions of this Service Bulletin include procedures given in
other documents or in other sections of the Service Bulletin. When the words “refer to”
are used and the operator has a procedure accepted by the local authority he belongs to,
the accepted alternative procedure can be used. When the words “in accordance with”
are used then the given procedure must be followed.
NOTE: The access and close-up instructions, not comprising return to service tests, in this
Service Bulletin do not constitute or affect the technical intent of the Service Bulletin.
Operators can therefore, as deemed necessary, omit or add access and/or close-up steps
to add flexibility to their maintenance operations as long as the technical intent of the
Service Bulletin is met within the set parameters.
NOTE: Manual titles given in the accomplishment instructions are referred to by acronyms. Refer
to paragraph 1.J., References, for the definition of acronyms.
NOTE: This Service Bulletin contains the instructions for the on-aircraft maintenance necessary
to ensure the continued airworthiness of the aircraft.
For any deviations to the instructions, contact AIRBUS for further instructions and
approval.
Man-hours 0.50 h
Minimum Number of person 1
Elapsed Time 0.50 h
Referenced Information
Manuals/Drawings References/Sheets
Task 12-34-24-869-002
AMM
Task 22-82-12-000-001
Procedure
NOTE: For the basic Aircraft configuration, refer to AMM Chapter "Introduction -
Aircraft status for maintenance" in Manual Front Matter section.
(a) Make sure that the aircraft is electrically grounded, refer to Ref. AMM Task 12-34-
24-869-002.
(b) Do the preparation procedure as specified in the removal of the MCDUs (FIN
3CA1, FIN 3CA2 and, if installed FIN 3CA3), refer to Ref. AMM Task 22-82-12-000-
001.
C. PROCEDURE
(1) Task A320-A-46-XX-1074-04001-920A-A (A320-A-46-XX-1074-04ZZZ-920Z-A)
Modify the Equipment and the Wiring in the Cockpit
Job Set-Up Information
Working Area
Man-hours 1.00 h
Minimum Number of person 1
Elapsed Time 1.00 h
Referenced Information
Manuals/Drawings References/Sheets
Task 22-82-12-000-001
AMM
Task 22-82-12-400-002
20-33-00
20-52-10
ESPM
20-52-21
20-54-50
Procedure
(a) Standard Practices:
1 Tag all the parts you must remove and retain to make the subsequent
installation easier.
2 For the general installation of electrical wire harnesses, refer to Ref. ESPM
20-33-00.
3 Do a check of the electrical connectors before you connect them, refer to
Ref. ESPM 20-52-10.
4 For the protection of the connectors, contacts and terminals, refer to Ref.
ESPM 20-54-50.
(b) Remove and retain the MCDUs (FIN 3CA1, FIN 3CA2 and if installed FIN 3CA3),
refer to Ref. AMM Task 22-82-12-000-001.
(c) Modify the wiring in the Center Pedestal Electrical Panel 11VU and in the LH Side
Console Electrical Panel 101VU.
1 Modify the connection of the wire(s) as shown on this(these) wiring
diagram(s) and the related hook-up chart(s):
- Ref. Fig. WM and Ref. Fig. HM.
(d) Do a continuity test of the new and/or modified electrical wires, refer to Ref.
ESPM 20-52-21.
(e) Install the retained MCDUs (FIN 3CA1, FIN 3CA2 and if removed FIN 3CA3), refer
to Ref. AMM Task 22-82-12-400-002.
CONF 002
BEFORE
A 2
F.R. -
8 R D
F.R.
7348 C
2
9 B L
-
F.R.
K
3CA1 MCDU-1
11VU 1103VT
210 120
F.R.
A
8 R
7349
9 B
3CA3 MCDU-3
101VU
211
A
2M
8 R 19
7350
F.R.
9 B 20
0569 21
3CA2 MCDU-2
11VU A 63VC
210 127
OLD HOOK-UP F.R. FOR REFERENCE EXISTING WIRE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2286
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1M
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-46XX1074-A-FAPE3-00HX7-A-002-01
CONF 002
AFTER
A 2
F.R. -
17 R D
F.R.
7348 C
2
18 B L
-
F.R.
K
3CA1 MCDU-1
11VU 1103VT
210 120
F.R.
A
17 R
7349
18 B
3CA3 MCDU-3
101VU
211
A
2M
17 R 19
7350
F.R.
18 B 20
0569 21
3CA2 MCDU-2
11VU A 63VC
210 127
NEW HOOK-UP F.R. FOR REFERENCE EXISTING WIRE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2286
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1M
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-46XX1074-A-FAPE3-00HX8-A-002-01
CONF 002
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
19
20
21
22
23
24
25
Man-hours 0.25 h
Minimum Number of person 1
Elapsed Time 0.25 h
Referenced Information
Manuals/Drawings References/Sheets
AMM Task 22-82-12-400-002
Procedure
(a) Remove the safety clip(s) and/or tag(s) and close/unlock the circuit breaker(s) as
specified after the installation of the MCDU, refer to Ref. AMM Task 22-82-12-400-
002.
E. TEST
(1) Task A320-A-46-XX-1074-01001-320A-A (A320-A-46-XX-1074-01ZZZ-320Z-A)
Test
Job Set-Up Information
Manpower/Resources/Skills
Man-hours 0.25 h
Minimum Number of person 1
Elapsed Time 0.25 h
Referenced Information
Manuals/Drawings References/Sheets
AMM Task 22-82-12-400-002
Procedure
(a) Do the test procedure as specified after the installation of the MCDU, refer to Ref.
AMM Task 22-82-12-400-002.
F. CLOSE-UP
(1) Task A320-A-46-XX-1074-03001-740A-A (A320-A-46-XX-1074-03ZZZ-740Z-A)
Close-up
Job Set-Up Information
Manpower/Resources/Skills
Man-hours 0.50 h
Minimum Number of person 1
Elapsed Time 0.50 h
Referenced Information
Manuals/Drawings References/Sheets
Task 22-82-12-400-002
AMM
Task 24-41-00-862-002
Procedure
(a) Make sure that the work areas are clean and clear of tools and other items of
equipment.
(b) De-energize the aircraft electrical circuits, refer to Ref. AMM Task 24-41-00-862-
002.
(c) Do the close-up procedure as specified in the installation of the MCDUs (FIN
3CA1, FIN 3CA2 and, if installed FIN 3CA3), refer to Ref. AMM Task 22-82-12-400-
002.
(d) Put the aircraft back to its initial configuration.
G. ADMINISTRATIVE
(1) Task A320-A-46-XX-1074-02001-90AA-A (A320-A-46-XX-1074-02ZZZ-90AZ-A)
Administrative
Procedure
Confirm in the applicable aircraft records that you have completed all the work defined
in this Service Bulletin task set as required.
WARNING: MAKE SURE THAT YOU OBEY ALL THE WARNINGS AND ALL THE CAUTIONS
INCLUDED IN THE REFERENCED PROCEDURES.
NOTE: The accomplishment instructions of this Service Bulletin include procedures given in
other documents or in other sections of the Service Bulletin. When the words “refer to”
are used and the operator has a procedure accepted by the local authority he belongs to,
the accepted alternative procedure can be used. When the words “in accordance with”
are used then the given procedure must be followed.
NOTE: The access and close-up instructions, not comprising return to service tests, in this
Service Bulletin do not constitute or affect the technical intent of the Service Bulletin.
Operators can therefore, as deemed necessary, omit or add access and/or close-up steps
to add flexibility to their maintenance operations as long as the technical intent of the
Service Bulletin is met within the set parameters.
NOTE: Manual titles given in the accomplishment instructions are referred to by acronyms. Refer
to paragraph 1.J., References, for the definition of acronyms.
NOTE: This Service Bulletin contains the instructions for the on-aircraft maintenance necessary
to ensure the continued airworthiness of the aircraft.
For any deviations to the instructions, contact AIRBUS for further instructions and
approval.
Man-hours 0.50 h
Minimum Number of person 1
Elapsed Time 0.50 h
Referenced Information
Manuals/Drawings References/Sheets
Task 12-34-24-869-002
AMM
Task 22-82-12-000-001
Procedure
NOTE: For the basic Aircraft configuration, refer to AMM Chapter "Introduction -
Aircraft status for maintenance" in Manual Front Matter section.
(a) Make sure that the aircraft is electrically grounded, refer to Ref. AMM Task 12-34-
24-869-002.
(b) Do the preparation procedure as specified in the removal of the MCDUs (FIN
3CA1, FIN 3CA2 and, if installed FIN 3CA3), refer to Ref. AMM Task 22-82-12-000-
001.
C. PROCEDURE
(1) Task A320-A-46-XX-1074-05001-920A-A (A320-A-46-XX-1074-05ZZZ-920Z-A)
Modify the Equipment and the Wiring in the Cockpit
Job Set-Up Information
Working Area
Man-hours 1.00 h
Minimum Number of person 1
Elapsed Time 1.00 h
Referenced Information
Manuals/Drawings References/Sheets
Task 22-82-12-000-001
AMM
Task 22-82-12-400-002
20-33-00
20-52-10
ESPM
20-52-21
20-54-50
Procedure
(a) Standard Practices:
1 Tag all the parts you must remove and retain to make the subsequent
installation easier.
2 For the general installation of electrical wire harnesses, refer to Ref. ESPM
20-33-00.
3 Do a check of the electrical connectors before you connect them, refer to
Ref. ESPM 20-52-10.
4 For the protection of the connectors, contacts and terminals, refer to Ref.
ESPM 20-54-50.
(b) Remove and retain the MCDUs (FIN 3CA1, FIN 3CA2 and if installed FIN 3CA3),
refer to Ref. AMM Task 22-82-12-000-001.
(c) Modify the wiring in the Center Pedestal Electrical Panel 11VU and in the LH Side
Console Electrical Panel 101VU.
1 Modify the connection of the wire(s) as shown on this(these) wiring
diagram(s) and the related hook-up chart(s):
- Ref. Fig. WL and Ref. Fig. HL.
(d) Do a continuity test of the new and/or modified electrical wires, refer to Ref.
ESPM 20-52-21.
(e) Install the retained MCDUs (FIN 3CA1, FIN 3CA2 and if removed FIN 3CA3), refer
to Ref. AMM Task 22-82-12-400-002.
CONF 002
BEFORE
A 2
F.R. -
17 R D
F.R.
7348 C
2
18 B L
-
F.R.
K
3CA1 MCDU-1
11VU 1103VT
210 120
F.R.
A
17 R
7349
18 B
3CA3 MCDU-3
101VU
211
A
2M
17 R 19
7350
F.R.
18 B 20
0569 21
3CA2 MCDU-2
11VU A 63VC
210 127
OLD HOOK-UP F.R. FOR REFERENCE EXISTING WIRE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2286
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1M
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-46XX1074-A-FAPE3-00HX5-A-002-01
CONF 002
AFTER
A 2
F.R. -
8 R D
F.R.
7348 C
2
9 B L
-
F.R.
K
3CA1 MCDU-1
11VU 1103VT
210 120
F.R.
A
8 R
7349
9 B
3CA3 MCDU-3
101VU
211
A
2M
8 R 19
7350
F.R.
9 B 20
0569 21
3CA2 MCDU-2
11VU A 63VC
210 127
NEW HOOK-UP F.R. FOR REFERENCE EXISTING WIRE NOTE : UNLESS OTHERWISE SPECIFIED PREFIX ALL WIRE IDENTIFICATION WITH ATA 2286
UNLESS OTHERWISE SPECIFIED ALL WIRES ARE TK24 GAUGE
UNLESS OTHERWISE SPECIFIED ALL ROUTES ARE 1M
SHIELDING CONTINUITY WIRES ARE CF24 GAUGE
ICN-A320-A-46XX1074-A-FAPE3-00HX6-A-002-01
CONF 002
L
END1 LEAD END2
i
n Instructions
Zone or Wire Length Zone or
e
Panel Elec.Ident. Term Terminal P/N Ident. Co Rte Gauge mm Inch Panel Elec.Ident. Term Terminal P/N
19
20
21
22
23
24
25
Man-hours 0.25 h
Minimum Number of person 1
Elapsed Time 0.25 h
Referenced Information
Manuals/Drawings References/Sheets
AMM Task 22-82-12-400-002
Procedure
(a) Remove the safety clip(s) and/or tag(s) and close/unlock the circuit breaker(s) as
specified after the installation of the MCDU, refer to Ref. AMM Task 22-82-12-400-
002.
E. TEST
(1) Task A320-A-46-XX-1074-02001-320A-A (A320-A-46-XX-1074-02ZZZ-320Z-A)
Test
Job Set-Up Information
Manpower/Resources/Skills
Man-hours 0.25 h
Minimum Number of person 1
Elapsed Time 0.25 h
Referenced Information
Manuals/Drawings References/Sheets
AMM Task 22-82-12-400-002
Procedure
(a) Do the test procedure as specified after the installation of the MCDU, refer to Ref.
AMM Task 22-82-12-400-002.
F. CLOSE-UP
(1) Task A320-A-46-XX-1074-05001-740A-A (A320-A-46-XX-1074-05ZZZ-740Z-A)
Close-up
Job Set-Up Information
Manpower/Resources/Skills
Man-hours 0.50 h
Minimum Number of person 1
Elapsed Time 0.50 h
Referenced Information
Manuals/Drawings References/Sheets
Task 22-82-12-400-002
AMM
Task 24-41-00-862-002
Procedure
(a) Make sure that the work areas are clean and clear of tools and other items of
equipment.
(b) De-energize the aircraft electrical circuits, refer to Ref. AMM Task 24-41-00-862-
002.
(c) Do the close-up procedure as specified in the installation of the MCDUs (FIN
3CA1, FIN 3CA2 and, if installed FIN 3CA3), refer to Ref. AMM Task 22-82-12-400-
002.
(d) Put the aircraft back to its initial configuration.
G. ADMINISTRATIVE
(1) Task A320-A-46-XX-1074-03001-90AA-A (A320-A-46-XX-1074-03ZZZ-90AZ-A)
Administrative
Procedure
Confirm in the applicable aircraft records that you have completed all the work defined
in this Service Bulletin task set as required.
NOTE: "X" is used for the modifications embodied before accomplishment of this Service
Bulletin.
NOTE: "X" is used for the retrofitted modifications after the accomplishment of this Service
Bulletin.
NOTE: ISI 00.00.00179 covers all the frequently asked questions about SB Reporting.
It is revised on a regular basis.
If you have difficulties in the accomplishment of this SB please quote below the area(s) and
give a short description of the issue.
Comments :
Operator : Date :
Name/Title
Please return this form to :
AIRBUS
2, ROND POINT EMILE DEWOITINE
31700 BLAGNAC
FRANCE
Or via your Resident Customer Support Office.