Plan at Canopy Top Level: Admin Block
Plan at Canopy Top Level: Admin Block
Plan at Canopy Top Level: Admin Block
OTHERWISE MENTIONED
2) AT TOLL PLAZA LOCATION RIGID PAVEMENT
SHALL BE PROVIDED.
ADMIN BLOCK
T6 T7
0%
0%
LANE-1 FOR ELECTRIC CABLE
2.5%
2.5%
DETAIL -Z
0%
0%
LANE-2
0%
2.5%
0%
2.5%
LANE-2
0%
LANE-1
0%
131+020 EXTRA WIDE LANE
0%
0%
T8 T5 T1 T2 T3 T4
HIGHWAY LIGHTING
FLEXIBLE PAVMENT
T7 T6
HIGH MAST POLE
LEGEND:-
CANOPY CANOPY HIGH MAST POLE
0%
0%
LANE-1 FOR ELECTRIC CABLE
TOLL BUILDING
2.5%
2.5%
0%
0%
LANE-2
EXTRA WIDE VEHICLE
&
SHOULDER EXTRA WIDE VEHICLE SHOULDER
0%
2.5%
0%
EXEMPTED VEHICLE LANE
2.5%
& LANE-2
EXEMPTED VEHICLE LANE
0%
0%
LANE-1
TOLL LANE - 1 TOLL LANE - 2 TOLL LANE - 3 TOLL LANE - 3 TOLL LANE - 2 TOLL LANE - 1 EXTRA WIDE LANE
0%
0%
CANOPY(12.5X 22.8)
0%
0%
0%
0%
0%
0%
0%
0%
0%
Note:- Loaction of admin block may change as per the site requirement
CANOPY(12.5X 22.8)
T3 T3
SHS150x150x6mm
T4 T4
T2 T2
C1 C1 C1
T4 T4
T4 T4
T1
T1
T1
T2 T2
T4 T4
T4 T4
12mm ThK. Stiffeners
T2 T2
16mm ThK. Base Plate
16mm dia. HT bolts
C1 C1 C1 Concrete Base Pedastal 8 nos.
450mm x 450mm
T4 T4
COLUMN DETAIL
T3 T3 12mm ThK.
Stiffenres 18mm dia. HT bolts
8 nos.
TOP PLAN 0.500 1.250 1.250 0.500
0.5
1.250 0.500
SHS
150mmx150mmx6mm
0.125
3.500
0.500 1.250
0.2
0.075 3.500
16 mm ThK.Base plate(BP1)
STEEL GRADE
0.1
12mm ThK. 350mm x 350mm Yst 310
INTEGRATE STEEL PLANT
Stiffenres MANUFACTURED STEEL SHALL BE
USED
~SHEET~
F1 F1 F1
F1 F1 F1
FOUNDATION PLAN
~SHEET~
TRUSS 2
MEMBER NOS SECTION LENGTH(mm) U.W.(kg/m) T.W.(kg)
3.15 1 RAFTER 268.800 6.02 1618.17
A4 60 x 40 X 4.5 RHS
0 6
4.76 WEB 312.590 1.36 425.12
A5 25 x 25 x 2.0 SHS
TRUSS 3
MEMBER NOS SECTION LENGTH(mm) U.W.(kg/m) T.W.(kg)
RAFTER 179.200 6.02 1078.78
A4 60 x 40 X 4.5 RHS
WEB 215.400 1.36 292.944
A5 25 x 25 x 2.0 SHS
7.770
5.516
TRUSS 4
6.000
0.28 0.3
ELEVATION OF TRUSS T1 AT GRID 1,2 & 3
0.3
SECTION A-A
0.9
0.3
SECTION B-B
SECTION C-C
STEEL GRADE
Yst 310
INTEGRATE STEEL PLANT
MANUFACTURED STEEL SHALL BE
USED
~SHEET~
120
80
60
120 Lg. Angle cut
X from same size of
RHS to fit in Smaller Member
FIELD SPLICE
C
Full Strenght 2
C/L Splice material to be plug
welded (Ground flush)
X VIEW -X-X
C A
A
B
C F
with inside sleeve
(For SHS)
SHOP SPLICE
12
12
12
VIEW -Y-Y VIEW -Y-Y VIEW -Y-Y
(For RHS upto 96 x 48) (For SHS upto 72 x 72) (For SHS 91.5 X 91.5
upto SHS 132 x 132)
t1 t1
Y
G
from same size of
C F
RHS to fit in
12
VIEW -Y-Y
VIEW -X-X (For RHS upto 122 X 61
(For RHS) upto RHS 172 x 92)
NOTES:
Size of Plate Bolt Grade (b) Class 4.6 Bolt Grade (b) Class 4.6 1) The details are based on the worst design loading for
Smaller Member Thickness the group and may be improved upon based on
Hole
t1 t2 Dia(D) Dia(D) Nos. A B C E F G actual loading.
SHS 38 x 38 x 4 / RHS 50 x 50 x 3.2 8 6 16 18 4 100 - 27 90 110 -
SHS 49.5 x 49.5 x 4.5 / RHS 66 x 33 x 4.5 8 6 20 22 4 120 - 33 110 140 - 2) Unless Otherwise Noted:
SHS 72 x 72 x 4.8 / RHS 96 x 48 x 4.8 10 6 25 27 4 150 - 40 130 180 -
a) All dimesions are in Millimeter.
b) All welds are 4 thk. fillet. 7mm ThK. WELDING IS TO BE USED UNLESS
SHS 91.5 x 91.5 x 4.5 / RHS 122 x 61 x 4.5 16 6 20 22 8 170 55 33 140 200 70
c) All bolts are of grade (B) class 4.6. OTHERWISE SPECIFIED
SHS 91.5 x 91.5 x 5.4 upto 132 x 132 x 5.4 / 20 6 25 27 8 220 70 40 180 260 90
RHS 122 x 61 x 5.4 upto 172 x 92 x 5.4
3) Open ends of all members shall be sealed.
W3 V2 W3 W3 V2
D1 OPEN OFFICE
5.445 X 5.0 M
URINAL
450
Lintel Beam
D3 UP DOWN
1200
100
2.835
450
RECEPTION
Main Reinforcement
1200
PLAN
W3 W3 W3 W3
150
LAYOUT PLAN
C C
345
450
460
225
Minimun 600 mm
(1:6 Cement Mortar)
150
75
1:2:3
750 1500
C C
SECTION OF COLUMN
L/7
Client : Authority Engineeer : EPC Contractor : Design Director : Proof Consultant : Project Drg No. : SCC/2020/NH-99/Toll Plaza/05
TASPL
DATE : June'2020 REVISION:
Toll Plaza Building
DESIGNED DRAWN CHECKED APPROVED
REV DATE DESCRIPTION IN THE STATE OF
NO JHARKHAND ON EPC (B.E. Civil) New Delhi - 110003 D.K R.T
15.150
5.100 1.750 2.355 2.778 2.917
Client : Authority Engineeer : EPC Contractor : Design Director : Proof Consultant : Project Drg No. : SCC/2020/NH-99/Toll Plaza/03
TASPL
Typical Toll Plaza DATE : June'2020 REVISION:
Canopy Foundation DESIGNED DRAWN CHECKED APPROVED
REV DATE IN THE STATE OF
DESCRIPTION