Plan at Canopy Top Level: Admin Block

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

1) ALL DIMENSIONS ARE IN METER UNLESS

OTHERWISE MENTIONED
2) AT TOLL PLAZA LOCATION RIGID PAVEMENT
SHALL BE PROVIDED.
ADMIN BLOCK
T6 T7

(Slope 1 in 10) HIGH MAST POLE (Slope 1 in 10)


Columns for Canopy (6 nos.) FLEXIBLE PAVMENT
T1 T2 T3 T4 T5 HIGHWAY LIGHTING T8
EXTRA WIDE LANE RIGID PAVMENT

UTILITY PIPE 150mm DIA


131+270

0%
0%
LANE-1 FOR ELECTRIC CABLE

2.5%
2.5%
DETAIL -Z

0%
0%
LANE-2

0%
2.5%

0%

2.5%
LANE-2

0%
LANE-1

0%
131+020 EXTRA WIDE LANE

0%

0%
T8 T5 T1 T2 T3 T4

HIGHWAY LIGHTING
FLEXIBLE PAVMENT

T7 T6
HIGH MAST POLE

PLAN AT TOLL BOTH LEVEL


(Toll Plaza Location at Ch. 31+145)
CLPROPOSED ROAD
ADMIN BLOCK

LEGEND:-
CANOPY CANOPY HIGH MAST POLE

HIGHWAY LIGHTING EXTRA WIDE LANE


POLE
UTILITY PIPE 150mm DIA

0%
0%
LANE-1 FOR ELECTRIC CABLE
TOLL BUILDING

2.5%
2.5%

0%
0%
LANE-2
EXTRA WIDE VEHICLE
&
SHOULDER EXTRA WIDE VEHICLE SHOULDER

0%
2.5%

0%
EXEMPTED VEHICLE LANE

2.5%
& LANE-2
EXEMPTED VEHICLE LANE

0%
0%
LANE-1

TOLL LANE - 1 TOLL LANE - 2 TOLL LANE - 3 TOLL LANE - 3 TOLL LANE - 2 TOLL LANE - 1 EXTRA WIDE LANE

0%

0%
CANOPY(12.5X 22.8)

CROSS SECTION AT "A- A" PLAN AT CANOPY TOP LEVEL

T1 Cantilever Gantry Sign For Toll Road Start

0%
0%

T2 Cantilever Gantry Sign For Toll gate 1.0km


T3 Kerb Sign For Toll Gate 500 m and toll rate

0%
0%

T4 Kerb Sign For Exempt vehicles


T5 Kerb Sign For pictorial dipiction of toll rates

0%
0%

T6 Kerb Sign For Exempt and over size vehicle


lane direction sign
T7 Sign near tollbooths dispalying toll rates,

0%
0%

exempt vehicle and complaint telephone


T8 Cantilever Gantry Sign For Toll Road End
0%

0%
Note:- Loaction of admin block may change as per the site requirement
CANOPY(12.5X 22.8)

PLAN AT CANOPY TOP LEVEL


Client : Authority Engineeer : EPC Contractor : Design Director : Proof Consultant : Project Drg No. : SCC/2020/NH-99/Toll Plaza/01
TASPL
DATE : June'2020 REVISION:
Typical Toll Plaza Plan
DESIGNED DRAWN CHECKED APPROVED
REV DATE DESCRIPTION IN THE STATE OF
NO JHARKHAND ON EPC (B.E. Civil) New Delhi - 110003 D.K R.T
16mm ThK. Shoe Plate 16mm dia. HT bolts
8 nos.
16mm ThK. Base Plate
CLPROPOSED ROAD
12mm ThK. Stiffeners

T3 T3

SHS150x150x6mm
T4 T4

T2 T2
C1 C1 C1
T4 T4

T4 T4
T1

T1

T1
T2 T2

T4 T4

T4 T4
12mm ThK. Stiffeners
T2 T2
16mm ThK. Base Plate
16mm dia. HT bolts
C1 C1 C1 Concrete Base Pedastal 8 nos.
450mm x 450mm
T4 T4
COLUMN DETAIL

T3 T3 12mm ThK.
Stiffenres 18mm dia. HT bolts
8 nos.
TOP PLAN 0.500 1.250 1.250 0.500
0.5

1.250 0.500
SHS
150mmx150mmx6mm

0.125

3.500
0.500 1.250
0.2

0.075 3.500
16 mm ThK.Base plate(BP1)
STEEL GRADE
0.1
12mm ThK. 350mm x 350mm Yst 310
INTEGRATE STEEL PLANT
Stiffenres MANUFACTURED STEEL SHALL BE
USED
~SHEET~

DRAWN BY: GS TITLE: TRUSS LAYOUT


1 PROJECT CHECKED BY: S S
DATE: 01-12-2015 SHEET NO: STR-1/6/2_R1
1 TOLL PLAZA SCALE: NOT TO SCALE GOOD FOR CONSTRUCTION
CLPROPOSED ROAD

PD1 PD1 PD1

F1 F1 F1

PD1 PD1 PD1

F1 F1 F1

FOUNDATION PLAN
~SHEET~

DRAWN BY: GS TITLE:


1 PROJECT CHECKED BY: S S
FOUNDATION LAYOUT

DATE: 01-12-2015 SHEET NO: STR-1/6/2_R1


1 TOLL PLAZA SCALE: NOT TO SCALE GOOD FOR CONSTRUCTION
TRUSS 1
MEMBER NOS SECTION LENGTH(mtr.) U.W.(kg/m) T.W.(kg)
15.000
3.000 9.000 3.000 RAFTER 94.992 11.88 1128.50
A1 122 x 61 x 4.5 RHS
0.750 0.750 0.750 0.750 0.750 0.750 0.750 0.750 0.750 0.750 0.750 0.750 0.750 0.750 0.750 0.750 0.750 0.750 0.750 0.750 WEB 70.370 4.98 350.44
A2 50 x 50 X 3.6 RHS
WEB 33.096 26.40 873.73
A3 150 x 150 x 6.0 SHS

TRUSS 2
MEMBER NOS SECTION LENGTH(mm) U.W.(kg/m) T.W.(kg)
3.15 1 RAFTER 268.800 6.02 1618.17
A4 60 x 40 X 4.5 RHS
0 6
4.76 WEB 312.590 1.36 425.12
A5 25 x 25 x 2.0 SHS

TRUSS 3
MEMBER NOS SECTION LENGTH(mm) U.W.(kg/m) T.W.(kg)
RAFTER 179.200 6.02 1078.78
A4 60 x 40 X 4.5 RHS
WEB 215.400 1.36 292.944
A5 25 x 25 x 2.0 SHS

7.770
5.516

TRUSS 4
6.000

MEMBER NOS SECTION LENGTH(mm) U.W.(kg/m) T.W.(kg)


RAFTER 268.800 6.02 1618.17
A4 60 x 40 X 4.5 RHS
WEB 231.600 1.36 314.976
A5 25 x 25 x 2.0 SHS

NOTE: ALL LENGTHS DIMENSIONS SPECIFIED IN THE BOQ ARE


C/C SIDES OF MEMBERS TO BE WORKED OUT AS PER SITE
CONDITION

0.28 0.3
ELEVATION OF TRUSS T1 AT GRID 1,2 & 3

0.3
SECTION A-A

0.9
0.3
SECTION B-B
SECTION C-C
STEEL GRADE
Yst 310
INTEGRATE STEEL PLANT
MANUFACTURED STEEL SHALL BE
USED
~SHEET~

DRAWN BY: GS TITLE: TRUSS LAYOUT


1 PROJECT CHECKED BY: S S
DATE: 01-12-2015 SHEET NO: STR-1/6/2_R1
1 TOLL PLAZA SCALE: NOT TO SCALE GOOD FOR CONSTRUCTION
t1 t1
TTYPICAL DETAILS OF SHOP & FIELD WELDED SPLICES

120
80
60
120 Lg. Angle cut
X from same size of
RHS to fit in Smaller Member
FIELD SPLICE

E C C A Hole (D) For A C


Hole (D) For Hole (D) For Bolt (d) B
Bolt (d) Bolt (d)

C
Full Strenght 2
C/L Splice material to be plug
welded (Ground flush)
X VIEW -X-X

C A

A
B
C F
with inside sleeve
(For SHS)
SHOP SPLICE

12

12

12
VIEW -Y-Y VIEW -Y-Y VIEW -Y-Y
(For RHS upto 96 x 48) (For SHS upto 72 x 72) (For SHS 91.5 X 91.5
upto SHS 132 x 132)
t1 t1
Y

Hole (D) For EC


Bolt (d) B

120 Lg. Angle cut


FIELD SPLICE Y

G
from same size of

C F
RHS to fit in

12
VIEW -Y-Y
VIEW -X-X (For RHS upto 122 X 61
(For RHS) upto RHS 172 x 92)

TYPICAL BOLTED COUPLING JOINTS

NOTES:
Size of Plate Bolt Grade (b) Class 4.6 Bolt Grade (b) Class 4.6 1) The details are based on the worst design loading for
Smaller Member Thickness the group and may be improved upon based on
Hole
t1 t2 Dia(D) Dia(D) Nos. A B C E F G actual loading.
SHS 38 x 38 x 4 / RHS 50 x 50 x 3.2 8 6 16 18 4 100 - 27 90 110 -
SHS 49.5 x 49.5 x 4.5 / RHS 66 x 33 x 4.5 8 6 20 22 4 120 - 33 110 140 - 2) Unless Otherwise Noted:
SHS 72 x 72 x 4.8 / RHS 96 x 48 x 4.8 10 6 25 27 4 150 - 40 130 180 -
a) All dimesions are in Millimeter.
b) All welds are 4 thk. fillet. 7mm ThK. WELDING IS TO BE USED UNLESS
SHS 91.5 x 91.5 x 4.5 / RHS 122 x 61 x 4.5 16 6 20 22 8 170 55 33 140 200 70
c) All bolts are of grade (B) class 4.6. OTHERWISE SPECIFIED
SHS 91.5 x 91.5 x 5.4 upto 132 x 132 x 5.4 / 20 6 25 27 8 220 70 40 180 260 90
RHS 122 x 61 x 5.4 upto 172 x 92 x 5.4
3) Open ends of all members shall be sealed.

4) Bolt locations are tentative and may be adjusted to


suit Girder configuration
~SHEET~

DRAWN BY: GS TITLE:


1 PROJECT CHECKED BY: S S
TYPICAL DETAIL

DATE: 01-12-2015 SHEET NO: STR-6/6/2_R1


1 TOLL PLAZA SCALE: NOT TO SCALE GOOD FOR CONSTRUCTION
15.150

5.100 1.750 2.355 5.695

W3 V2 W3 W3 V2

D1 0.9 X 2.10 (Meters)


W.C D3 D2 0.75 X 2.10 (Meters)
1.50 X 1.30 M
D1 1.20 X 2,10 (Meters)
W1 1.50 X 1.20 (Meters)
2.625

FASTTAG ISSUANCE ROOM TOILET


4.85 X 2.25 M 1.30 X 1.80 M
W2 1.20 X 1.20 (Meters)
D3
W3 1.00 X 1.20 (Meters)
V1 0.6 X 0.60 (Meters)
W
5.458

D1 OPEN OFFICE
5.445 X 5.0 M
URINAL

450
Lintel Beam
D3 UP DOWN

1200
100
2.835

450
RECEPTION

PASSAGE 1.30 M WIDE D1

Main Reinforcement
1200

PLAN
W3 W3 W3 W3

150
LAYOUT PLAN

C C

230 8 mm dia 250 mm c/c Striups

300mmX230mm 12 mm dia 6 nos


10mm dia bars @ 175mm c/c
alternate bars bent up at L/7 Column

345

Brick Work 12 mm dia 250 mm

450
460

225
Minimun 600 mm
(1:6 Cement Mortar)

from hard soil


c/c Bothways
575
PCC 1:4:8 150 PCC 1:4:8

150

75
1:2:3
750 1500

C C

SECTION OF COLUMN
L/7

REINFORCEMENT DETAIL SECTION OF WALL


L/7

10mm dia bars @ 200mm c/c


alternate bars bent up at L/7

Client : Authority Engineeer : EPC Contractor : Design Director : Proof Consultant : Project Drg No. : SCC/2020/NH-99/Toll Plaza/05
TASPL
DATE : June'2020 REVISION:
Toll Plaza Building
DESIGNED DRAWN CHECKED APPROVED
REV DATE DESCRIPTION IN THE STATE OF
NO JHARKHAND ON EPC (B.E. Civil) New Delhi - 110003 D.K R.T
15.150
5.100 1.750 2.355 2.778 2.917

Client : Authority Engineeer : EPC Contractor : Design Director : Proof Consultant : Project Drg No. : SCC/2020/NH-99/Toll Plaza/03
TASPL
Typical Toll Plaza DATE : June'2020 REVISION:
Canopy Foundation DESIGNED DRAWN CHECKED APPROVED
REV DATE IN THE STATE OF
DESCRIPTION
NO JHARKHAND ON EPC (B.E. Civil) New Delhi - 110003 D.K R.T

You might also like