Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

DrainStar® DSC-999 10.0.75.

0
Sheet 1
Simple Calculation

Project File: PF1 081821.PRO Date: 13/03/2021


Project No.: Index:
Project Description: PF1
Project Location:
Consultant: Consultant Location:
Engineer: Engineer Phone No.:
Pipesystem: 2
Pipe System: HDPE Pipe Operational Roughness: 0.10

Roof Segment Number 1


Rain Collection Area (m2) 144.76
Rainfall (l/(s*ha)) 1,111.11
Coefficient of Discharge 1
Total Discharge (l/s) 16.1
Capacity of Individual Roof Outlet (l/s) 8.0
Number of Roof Outlets 2

Roof Discharge
Segment
Required Result
l/s l/s
1 16.1 16.1

Pipe System: HDPE Pipe

Drainage Required

Discharge Volume Achievable (l/s) 1.68


Discharge Volume Needed (l/s) 2.00
Maximum Nominal Diameter of the 1
Downpipe

Dimensioning of the Overflows

Hundred-Year Storm (l/(s*ha)) 2,222.22

Roof Segment No 1
Overflowing Volume Flow (l/s) 16.08
Lower Edge Emergency Overflow (cm) 5.00
Contraction Factor 0.60
Permitted Roof Load (kN/m2) 0.75
Height of Overfall (cm) 2.65
Permitted static Backwater Level (cm) 7.65

www.keidel-drainstar.com powered by Keidel DrainStar keidel@keidel-drainstar.com


DrainStar® DSC-999 10.0.75.0
Sheet 2
Simple Calculation

Project File: PF1 081821.PRO Date: 13/03/2021


Project No.: Index:
Project Description: PF1
Project Location:
Consultant: Consultant Location:
Engineer: Engineer Phone No.:
Pipesystem: 2
Pipe System: HDPE Pipe Operational Roughness: 0.10

Width of Overflow (m) 2.11

www.keidel-drainstar.com powered by Keidel DrainStar keidel@keidel-drainstar.com


DrainStar® DSC-999 10.0.75.0
Sheet 3
Simple Calculation

Project File: PF1 081821.PRO Date: 13/03/2021


Project No.: Index:
Project Description: PF1
Project Location:
Consultant: Consultant Location:
Engineer: Engineer Phone No.:
Pipesystem: 2
Pipe System: HDPE Pipe Operational Roughness: 0.10

List of Legs (TS) and Results of Hydraulic Calculation

Roof Pressure Pressure


Leg (TS) Segment DN Length v Loss px
No. No. l/s mm m m Zeta m/s mbar mbar

1 1 8.0 75 0.25 0.25 0.30 1.8 6.25 1.71


2 8.0 75 0.35 0.35 0.80 2.2 21.24 8.23
3 8.0 75 17.60 1.00 2.2 160.90 -152.67
4 16.1 75 5.00 1.10 4.3 252.53 -474.56
5 16.1 63 45.45 45.45 1.10 6.3 3,912.66 -36.45
6 16.1 110 3.20 0.80 2.0 28.95 113.50
13 16.1 110 4.60 0.80 2.0 34.74 78.76
7 16.1 110 28.60 0.80 2.0 135.17 -56.57
8 16.1 110 8.62 0.80 2.0 51.34 -107.75
9 16.1 110 2.45 1.50 2.0 39.96 0.00

10 1 8.0 75 0.25 0.25 0.60 1.8 11.22 -3.26


11 8.0 63 0.35 0.35 1.40 3.2 76.81 -78.84

Pressure Difference of Flow Paths at Estimated Discharge

Available
Flow Path Pressure Pressure Loss Difference
No. mbar mbar mbar
1 4,515.70 4,603.77 -88.08
10 4,515.70 4,543.38 -27.68

Hydraulic Parameters

www.keidel-drainstar.com powered by Keidel DrainStar keidel@keidel-drainstar.com


DrainStar® DSC-999 10.0.75.0
Sheet 4
Simple Calculation

Project File: PF1 081821.PRO Date: 13/03/2021


Project No.: Index:
Project Description: PF1
Project Location:
Consultant: Consultant Location:
Engineer: Engineer Phone No.:
Pipesystem: 2
Pipe System: HDPE Pipe Operational Roughness: 0.10

Minimum Vacuum Zeta Values (single resistance values)

DN 40 -700.0 mBar Roof Outlet 0.30


DN 50 -700.0 mBar Branch 45° 0.60
DN 56 -700.0 mBar Reducer 0.30
DN 63 -700.0 mBar Increaser 0.30
DN 75 -700.0 mBar Transition 1.50
DN 90 -700.0 mBar 15° Bend 0.10
DN 110 -700.0 mBar 30° Bend 0.30
DN 125 -700.0 mBar 45° Bend 0.40
DN 160 -700.0 mBar 70° Bend 0.60
DN 200 -700.0 mBar 90° Bend 0.80
DN 250 -700.0 mBar
DN 315 -700.0 mBar Operational Roughness
Operational Roughness 0.100 mm
Flow Velocity
Minimum flow velocity 0.5 m/s Other Values
Flow Velocity Discharge 2.5 m/s Density of the Water 999.60 kg/m3
Acceleration due to Gravity 9.81 m/s2
Kinematic Viscosity 1.31 *10-6 m2/s

www.keidel-drainstar.com powered by Keidel DrainStar keidel@keidel-drainstar.com