Version 2008 27.8.

13 DF0C - 9D43 - 7A4C - D414 - D63F - 94AD


conformingtoVDI 3806

Adjust hydraulically Sheet: 1

Project file: Lorowerk Projekt 1.GPR Date: 06.10.2020


Project no.: Q-05368 Index:
Project name: Z2 TOWER
Project location: TAGUIG CITY,PHILIPPINES
Consultant: MEINHARDT PHILIPPINES
OrtPlaner MAKATI CITY
Engineer: JOVITO C . BORJA
Engineer - telephone:
Pipe system: 2

Roof area number [-] 1


Rain collection area [m²] 144.7
6
Rainfall [l/sec/ha] 1111.
1
Coefficient of discharge [-] 1
Total discharge [l/sec] 16.1
Capacity of individual roof drain 8.0
[l/sec]
Number of roof drains 2

Roof area Discharge


Required Result
l/s l/s
1 16.1 23.1

Type of pipe: Loro-X Steel Discharge Pipes


List of pipe sections and results of hydraulic calculation:

Pipe section Area DN Length v Pressure loss Pressure px


- No. l/sec - m m - m/sec mbar mbar

1 1 9.9 70 0.25 0.25 0.53 2.6 21.20 -30.26


2 9.9 70 0.25 0.25 0.80 2.6 30.27 -36.01
4 9.9 70 18.00 0.60 2.6 265.63 -301.64
5 23.1 80 5.00 1.10 4.0 211.65 -560.08
6 23.1 70 38.20 38.20 2.60 6.0 3265.40 -182.34
0 23.1 200 36.00 0.00 0.6 8.03 0.00
9 23.1 200 1.00 0.00 0.6 0.22 0.00

7 1 13.2 70 0.25 0.25 0.83 3.5 55.61 -90.84


8 13.2 50 0.25 0.25 1.00 6.7 261.75 -495.23

Pressure difference between flow paths when hydraulically adjusted:

Flow path Available pressure Pressure loss Difference


- mbar mbar mbar

1 3794.95 3794.15 0.80


7 3794.95 3794.41 0.54

powered by KEIDEL software


Version 2008 27.8.13 DF0C - 9D43 - 7A4C - D414 - D63F - 94AD
conforming to VDI 3806

Adjust hydraulically Sheet: 2

Project file: Lorowerk Projekt 1.GPR Date: 06.10.2020


Project no.: Q-05368 Index:
Project name: Z2 TOWER
Project location: TAGUIG CITY,PHILIPPINES
Consultant: MEINHARDT PHILIPPINES
OrtPlaner MAKATI CITY
Engineer: JOVITO C . BORJA
Engineer - telephone:
Pipe system: 2

Notice
The calculations will be made to the best of our knowledge on the basis of the building plans submitted
to us or of the details furnished. However, this shall not release the contractor from his responsibility
to check and verify all geometrical data concerning the roof drainage and to compare
the data furnished with the actual conditions on site.

Notice to program users


The calculation program for LORO DRAINJET® RAPID DRAINING SYSTEMS is a service provided free of charge
by LOROWERK K.H. Vahlbrauk GmbH & Co. KG an can only be used on the basis of the users own responsibility.
No legal claims whatsoever brought against LOROWERK K.H. Vahlbrauk GmbH & Co. KG
in this respect shall be entertained.

powered by KEIDEL software

You might also like