Model no.

: LS-8076-zwave
Operation Guide
1 Keypad instructions
 “0-9” digit button: codes button
 “*” button: return or quit button
 “#”button: confirm or wake up button
 “Reset” button on the back panel
2 Unlocking method:
 Zwave command, code, card, backup mechanical key

3 User capacity
Master code: 1pcs (6-8 digits, default master code is 123456)
User card: 100pcs (user ID: 001-100)
User code: 100pcs (user ID 001-100

4 Door lock setting introduction


4.1 Change Mater code
Input default master code “123456” press “#”,  short press “reset button” on the back
panel  input the new master code with 6-8 digits and press “#” to confirm  input the
new master code with 6-8 digits again, press “#” to confirm. Master code changed
successfully.
Remark:
 Card, code can only be added after the factory default master code modified
 New master code must be different with the default master code
 When modify default master code, the second input codes must be same as the first
input code.

4.2 Add / Delete User Card


Input the master code end with #  Press 1  Press 1  Input 3 digit user ID (001-
100)  Put the card on card sensor  Input beginning time or press #  Input
ending time or press #. Card user added successfully.

Input the master code end with #  Press 2  Press 1  Input the user ID (001-100)
– Press #, the user card deleted successfully.

Remark:
 In the card adding status, you can add more user card continually.
 If you don’t want card user with time restriction, just press “#” button.

4.3 Add / Delete User Code


Input the master code end with #  Press 1  Press 2  Input 3 digit user ID (001-
100)  Input user code (6-8 digits) end with #  Input user code (6-8 digits) again
end with #  Input beginning time or press #  Input ending time or press #. Code
user added successfully.

Input the master code end with #  Press 2  Press 2  Input the user ID (001-100)
– Press #, the user code deleted successfully.

Remark:
 In the code adding status, you can add more user code continually.
 If you don’t want code user with time restriction, just press “#” button.

4.4 Zwave gateway enroll / unenroll


Operate on APP to add / delete zwave device, input the master code end with #
Press 0  Press 0, the lock is in enrolling / unenrolling status.
Remark:
 If the lock has been registered on other zwave gateway, please unenroll the lock first,
then enroll it.

5 Door lock system setup


5.1 Door lock time setup
Input the master code end with # Press 3  Press 1  Input current time: year-month-
date-hour-minute (e.g. current time: 12:00am 20/09/2013, input 1309201200)

5.2 Door lock alarm setup / cancel


Input the master code end with # Press 3  Press 2  set up alarm / cancel alarm.

5.3 Chinese / English voice navigation switch


Input the master code end with # Press 3  Press 3  Switch Chinese to English or
Switch English to Chinese.

6 “Passage Mode” function setup / cancel


Input the master code end with #  Press 4  “Passage mode” function setup successfully.

Unlock the door with user code, user card  “Passage mode function cancelled successfully.

7 Door lock clock reporting


Input the master code end with #  Press 5  The current door lock clock is xx(year)
xx(month) xx(date) xx(hour) xx(minute)

8 Door lock event record reporting


Input the master code end with #  Press 6  Report circulatory from the latest unlocking
record to the first one.

9 Voice volume adjustment


Input the master code end with #  Press 8  Press 2 to higher volume; Press 8 to lower
volume.
10 Restore factory defaults setting
Press reset button on the back panel for 5 seconds, sound DiDi, restore factory default
setting successfully.
Remark:
 After restore factory default setting, the master code must be modified before adding
user card/code.
 After restore factory default setting, the previously user card / user codes are all
deleted.

11 Malfunction prevention function


When 5 failed authentication attempt with unregistered code / fingerprint occur, the lock
stop operating for 3 minutes.

12 Low battery alarm function


4pcs AA Alkaline battery (6V), when battery voltage is lower than 5.0V, the door lock will
voice prompt “low battery, replace it”

13 Battery box and reset button