Punching Shear Calculation For Foundations: Member: Position
Punching Shear Calculation For Foundations: Member: Position
Member:
Position:
Standard: EN 1992-1-1
Concrete: C40/50
Reinforcement: BSt 420
Punching load: V_Ed = 1500.00 kN
Slab:
Column:
V_Ed
Rectangular section (Interior column): w= 45.00 cm
h= 45.00 cm
Avg. soil pressure: sigma_m = 0.00 kN/m² 0.0
Results:
45.0 cm
Characteristic compressive strength: fck_cyl = 58.52 MN/m²
Design value of reinforcement yield stress: f_ywd_ef = 247.71 MN/m²
Increasing factor for unsym. load contribution: = 0.63
Degree of tension reinforcement: = 0.470 %
Middle effective height: d= 44.35 cm
Minimum punching reinforcement (per link): min A_sv = 0.29 cm² 45.0 cm
121.0 cm
Required punching reinforcement: requ A_sv = 0.00 cm²
Min. required length of punching reinforcement: l_s = 34.02 cm y
121.0 cm
45.0 cm
Proof: