Professional Documents
Culture Documents
Reda Esp Catalog
Reda Esp Catalog
Pump Technology
ESP Catalog Digitally signed by
Morhaf
Morhaf Hamdo
DN: cn=Morhaf
Hamdo,
Hamd o=Schlumberger,
ou=ALS,
Introduction email=mhamdo@s
o lb.com, c=US
Date: 2010.05.07
17:44:34 -05'00'
Getting started
1. For optimal viewing of this catalog, it is recommended that you install the latest version of Adobe®
Acrobat® Reader ® software. The necessary files have been provided on this CD for immediate
installation. If you need Reader for an operating system other than the ones provided, click here to
download the appropriate version. Type Control + k for the options page.
2. By default, Reader opens and views linked PDF documents in one window to minimize the number Want to know more?
of windows open. However, this option may make navigation in this catalog more difficult. To have Click the Schlumberger logo
a linked document open in a separate window—leaving the catalog menu active—uncheck the at the bottom of the navigation
Open cross-document links in same window option in the General section of your Reader pages to visit the Artificial Lift
Preferences. web site.
Note: To override this setting without changing your preferences, you can press Ctrl (in Microsoft®
Windows®) or Option (in Mac OS®) when selecting a link.
3. To have this interactive catalog on your hard drive, copy the entire contents of this CD into a single
folder. Please note that all of the files on this CD must be in the same folder for proper navigation.
Go to Catalog Contents
*Mark of Schlumberger
Other company, product, and service names are the properties
of their respective owners.
REDA Electric Submersible
Pump Technology
ESP Catalog
Help
For help using Adobe Acrobat Reader, press the F1 key or click
here to access Adobe Acrobat online help.
Contents
QHSE
Application Engineering
Optimization Services
Advanced Applications
Downhole Monitoring
ESP Components
Surface Power and Control
Application Engineering
ESP system components
Basic equipment selection
Effect of VSD on the ESP system
DesignPro* ESP Software
ESP Design Data Sheet
Pumps
Pump Intakes
Protectors
Motors
Maximus* Components
Power Cable
Pumps
Summary Table
Pump Nomenclature
Bolt-On Pump Discharge Heads
338 Series AN550 AN900 AN1200 AN1500 A2700N
387 Series D3050N D3400N D5850N
400 Series D475N D725N DN1100 D1400N DN1750 DN1800
DN2150 D2400N DN3000 DN3100 D4300N D5800N
540 Series GN1600 GN2100 GN3200 GN4000 GN5200 G6200N
GN7000 GN10000
continued
Pump Intakes
Standard Intakes
Vortex Gas Separators
Advanced Gas Handler
Poseidon*
Product Tables
Protectors
Motors
Motors
ProMotors
Protectors
Motorlead Extensions
Power Cable
QHSE
Quality, Health, Safety, and Environment
Application Engineering
Application Engineering
DesignPro* ESP design and analysis ■ black oil properties with option
software is a sophisticated software for extensive PVT laboratory data,
package for sizing and analyzing an viscosity calibration, and emul-
entire ESP system. Designed to be sion effects
intuitive with a highly logical work- ■ predicting reservoir performance
flow, the software is extremely user by inflow methods with the option
friendly. In addition, it has some of the to consider water cut
most advanced models in the software ■ providing complete gas handling
engine to accurately predict the per-
or gas separation performance
formance of each ESP component.
analysis
The DesignPro software was devel-
■ providing advanced features for
oped with the assistance and close
cooperation of REDA ESP domain changing the performance of the
experts. pump or any other components
The software contains an intuitive to match the measured data
workflow to navigate through the ■ applying motor and pump heat-
application design in a logical and increase effects on equipment
concise manner. Modules define the performance
wellbore schematic and accurately ■ applying a complete heat transfer
size all the downhole and surface from reservoir to the separator
components. The software simplifies ■ using the pump test data for
the process of optimizing and accu-
design and analysis instead
rately predicting the future perform-
of catalog curves
ance under different conditions with
■ Microsoft® Word and PDF report
extensive case comparison capability.
DesignPro software provides the generation capability.
latest information on ESP equipment DesignPro software uses animated
and utilizes the fluid, well, and reser- simulations to view fluid levels in
voir information to predict the inflow the annulus and tubing. It simulates
and outflow performance of an ESP the system condition from the start
system design. The software fea- of the operation to the time when
tures helpful error messaging and the system stabilizes and the fluid
a detailed limitation report to aid in level is constant. It also generates
properly selecting ESP equipment. a well schematic diagram detailing
Application features include the equipment type and the associ-
■ comprehensive selection of flow ated clearances.
and fluid correlations to better
match measured well data to iden-
tify the most suitable correlation
for the analysis
Company Field
Contact Location
Phone Fax Date Run date
General Information
This well has a history of ❏ Sand % ❏ Scale ❏ Paraffin
❏ H2S % ❏ CO2 % ❏ Other
Electrical supply summary Primary supply voltage
❏ Three phase ❏ Single phase
Any other unique production characteristics with this location
General Information
This well has a history of ❏ Sand % ❏ Scale ❏ Paraffin
❏ H2S % ❏ CO2 % ❏ Other
Electrical supply summary Primary supply voltage
❏ Three phase ❏ Single phase
Any other unique production characteristics with this location
Applications
■ Brownfields using artificial lift
■ Multilocation stakeholders
■ Resource-constrained operations
■ Fields and wells with variable
operating conditions
Benefits espWatcher
■ Improves run life through proactive
ESP management
■ Reduces up-front capital investment
■ Provides information on demand
for better, faster decisions
■ Provides diagnosis, analysis, and
recommendations from domain
experts
■ Improves utilization of operator
resources
Features
■ Simple wellsite installation
■ Real-time monitoring on every well
■ Remote intelligent surveillance
and control of ESP operations LiftPro
■ Secure Web access to all measured
parameters
■ Localized Production Centers of
Excellence staffed with ESP experts
REDA Phoenix
Applications
■ Mature fields with numerous wells
■ Remote environments
■ Subsea and high-value wells on ESPs
■ Wells with no or limited SCADA
systems
■ Lift-system-optimization candidates
Benefits
■ Increased pump and well uptime
■ Extended pump run life
■ Reduced well interventions
■ Prioritized well work
■ Improved pump operation
■ Optimized production
■ Reduced wellsite visits
■ Improved cost effectiveness of
installation, maintenance, and
system administration
Features
■ Real-time sandface and production
surveillance
■ Fully automated wellsite status
determination via the Internet
■ Secure, remote access to all meas- User security control,
Secure, two-way
ured parameters communication alarms and alert management,
data storage, and business
■ Secure, remote pump start, stop, process management
and variable speed drive (VSD)
adjustments Data and instructions
■ Pager, cellphone, or e-mail alarms transmission
and callouts
■ Daily raw data summary with Surveillance and Actions,
retained history control instructions data polling, Multidiscipline
■ and queries collaboration
On-demand data polling
and historical
■ Incorporation of additional wellsite interrogation
remote terminal units and data
■ Periodic pump and well perform-
ance analyses
■ Fast and economical setup Alarms and alerts Collaboration, analysis,
■ Scalable and configurable design planning, and decision making
Applications
■ Wells with bottomhole tempera-
ture (BHT) to 425°F [218°C]
■ Installations with insufficient
motor cooling
• Gassy wells
• Low-production-rate wells
• Wells with emulsified fluids
Benefits
■ Extended ESP run life in high-
temperature applications
■ Expanded ESP application range
Features
■ High-temperature motor insula-
tion system
■ High-temperature 562 Dominator*
motor
■ Protector available with labyrinth
seal or high-temperature elasto-
meric bag configurations
■ High-temperature pump
■ High-temperature power cable
and motor lead extension
High-temperature wells
The REDA* Hotline* high-temperature
ESP system is designed to address the
special needs of high-temperature
wells produced by steamflood opera-
tions. Steam injection has been used
in many fields to improve mobility of
heavy oil and bitumen, which are
more difficult to recover than light
oil. Because more than two-thirds of
worldwide oil reserves are heavy oil,
the role of steamflood as a recovery
technique will likely play a much big-
ger role in fulfilling hydrocarbon
demands in the near future.
Poseidon
system Conventional
Head relative Oil gas-handling
to single-phase production system
performance Conventional
gas-handling
system
Specifications
400 (D Series) 538 (S Series)
Outside diameter, in. [mm] 4.00 [101.6] 5.38 [136.65]
Length, ft [m] 6.9 [2.1] 6.3 [1.9]
Weight, lbm [kg] 182 [82.6] 350 [158.9]
Power consumption, 16 50
tested at 60 Hz and 1.0 sg water, hp
Standard housing material Carbon steel Carbon steel
Optional housing material Redalloy* alloy Redalloy alloy
Standard stage metallurgy Ni-Resist alloy Ni-Resist alloy
Optional stage metallurgy ASM† 5530 ASM 5530
Shaft material INCONEL® INCONEL
Shaft size, in. [mm] 7/8 [22.2] 1 [25.4]
Shaft power rating at 60 Hz, hp 410 600
Liquid and gas rate, B/D [m3/d] 800–4,200 [127–667.8] 5,000–9,000 [795–1,431]
GVF, % Up to 75 Up to 75
Stage type Helicoaxial Helicoaxial
† American Society for Metals
Gauge Metrology
Measurement Range Accuracy Resolution Drift Data Rate
Pressure (reservoir enhanced) 0–5,000 psi [0–34,474 kPa] 0.06% of full scale 0.03 psi [0.210 kPa] 5 psi/yr [34.5 kPa/yr] 2s
Intake pressure 0–5,000 psi [0–34,474 kPa] 0.10% of full scale 0.1 psi [0.69 kPa] 5 psi/yr [34.5 kPa/yr] 6s
Discharge pressure 0–5,000 psi [0–34,474 kPa] 0.10% of full scale 0.1 psi [0.69 kPa] 5 psi/yr [34.5 kPa/yr] 6s
Motor oil and winding temperature 0–768°F [0–409°C] 0.67% of full scale 32.2°F [0.1°C] na† 31 s
Temperature 0–302°F [0–150°C] 0.67% of full scale 32.2°F [0.1°C] na 6s
Vibration 0–30 gn 1.67% of full scale 0.1 gn na Variable
Current leakage 0–25 mA 0.20% of full scale 0.001 mA na Variable
Y-point voltage 0–900 V rms 2.00% of full scale 10 V rms na Variable
at 60 Hz
† not available
Gauge Specifications
Length, in. [cm] 22 [55.88]
Dimensions
OD, in. [cm] 4.50 [11.43]; 3.75 (optional) [9.53]
Pressure, psi [kPa] 5,800 [39,990]
Ratings Temperature, °F [°C] 257 [125]
Insulation test rating, VDC 5,000
Metallurgy Stainless steel AISI420
Materials
Elastomers As required
High-voltage coupling Surface choke
Surface equipment requirement
Data acquisition options UniConn universal site controller, integrated surface unit (ISP)
Gauge Metrology
Measurement Range Accuracy Resolution Drift Data Rate
Intake pressure 0–5,000 psi [0–34,474 kPa] 0.17% of full scale 1 psi [6.9 kPa] 5 psi/yr [34.5 kPa/yr] 20 s (1-s RSR†)
Discharge pressure 0–5,000 psi [0–34,474 kPa] 0.17% of full scale 1 psi [6.9 kPa] 5 psi/yr [34.5 kPa/yr] 20 s
Motor oil and winding temperature 32–617°F [0–325°C] 0.67% of full scale 0.18°F [0.1°C] na‡ 20 s
Intake temperature 32–257°F [0–125°C] 0.67% of full scale 0.18°F [0.1°C] na 20 s
Vibration 0–30 gn 1.67% of full scale 0.1 gn na 20 s
Current leakage 0–25 mA 0.20% of full scale 0.001 mA na 20 s
† Rapid sample rate for buildup survey
† not applicable
MultiSensor XT Configurations
Parameter Measured Type 0 Type 1
Intake pressure Yes Yes
Discharge pressure No Yes
Intake temperature Yes Yes
Motor temperature Yes Yes
Vibration Yes Yes
Current leakage Yes Yes
Instrument Cable for Integral REDA ESP Sensors and Remote Reservoir Sensor
Description Stainless Steel Part Number
Instrument cable for remote reservoir sensor, AISI 316L material† P486021
Instrument cable rated for 302°F [150°C], 160 ft [48.7 m], AISI 316L material† 100260321
Instrument cable rated for 392°F [200°C], 160 ft [48.7 m], AISI 316L material† 100260322
† Other cable material available on request
MultiSensor* XT Gauges
Description Max. Working Temperature Makeup Length, Carbon Steel Stainless Steel
Pressure, psi [kPa] Rating, °F [°C] in. [cm] Part Number Part Number
MultiSensor XT slimline gauge, 5,000 [34,474] 257 [125] 47 [119] na† 100232520
375 Series, Viton® elastomers
MultiSensor XT gauge, 5,000 [34,474] 257 [125] 22 [56] na 100079628
Type 0, Viton elastomers
MultiSensor XT gauge, 5,000 [34,474] 257 [125] 22 [56] na 100135997
Type 0, Aflas® elastomers
MultiSensor XT gauge, 5,000 [34,474] 257 [125] 22 [56] na 100079631
Type 1, Viton elastomers
MultiSensor XT gauge, 5,000 [34,474] 257 [125] 22 [56] na 100135995
Type 1, Aflas elastomers
† not available
Flange-Mounted REDA ESP Discharge Pressure Subs for MultiSensor XT Type 1 Gauge
Description Max. OD, in. [cm] Min. ID, in. [cm] Makeup Length, Carbon Steel Stainless Steel
in. [cm] Part Number Part Number
400 Series pumps, Viton O-rings 4.625 [11.75] 1.875 [4.76] 12 [30.48] 100144512 100144516
400 Series pumps, Aflas O-rings 4.625 [11.75] 1.875 [4.76] 12 [30.48] 100144513 100144517
513 Series pumps, Viton O-rings 5.135 [13.04] 2.615 [6.64] 12 [30.48] 100134145 100134148
513 Series pumps, Aflas O-rings 5.135 [13.04] 2.615 [6.64] 12 [30.48] 100134146 100134149
538 Series pumps, Viton O-rings 5.380 [13.67] 2.865 [7.28] 12 [30.48] 100134132 100134136
538 Series pumps, Aflas O-rings 5.380 [13.67] 2.865 [7.28] 12 [30.48] 100134133 100134139
562 Series pumps, Viton O-rings 5.615 [14.26] 2.990 [7.59] 9 [22.86] 100134154 100134158
562 Series pumps, Aflas O-rings 5.615 [14.26] 2.990 [7.59] 9 [22.86] 100134156 100134159
675 Series pumps, Viton O-rings 6.760 [17.17] 3.740 [9.50] 9 [22.86] 100134300 100134305
675 Series pumps, Aflas O-rings 6.760 [17.17] 3.740 [9.50] 9 [22.86] 100134302 100134308
Pumps
Return to Pumps
Return to Pumps
Pump Summary
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pump Nomenclature
Return to Pumps
Return to Pumps
Bolt-On Pump
Discharge Heads
338 Series
Part Number Description Length, ft [m] Weight, lbm [kg]
493015 2 3⁄8-in. [60.33-mm] OD 8rd EUE—Carbon steel 0.5 [0.15] 6 [2.7]
492223 2 3⁄8-in. [60.33-mm] OD 8rd EUE—Redalloy* alloy 0.5 [0.15] 4 [1.8]
400 Series
Part Number Description Length, ft [m] Weight, lbm [kg]
243485 2 ⁄8-in. [60.33-mm] OD 8rd EUE—Carbon steel
3
0.6 [0.18] 10 [4.5]
364240 2 3⁄8-in. [60.33-mm] OD 8rd EUE—Redalloy alloy 0.8 [0.24] 10 [4.5]
513/538 Series
Part Number Description Length, ft [m] Weight, lbm [kg]
194381 3 ⁄2-in. [88.90-mm] OD 8rd EUE—Carbon steel
1
0.8 [0.24] 22 [10.0]
492231 31⁄2-in. [88.90-mm] OD 8rd EUE—Redalloy alloy 0.8 [0.24] 21 [10.0]
562 Series
Part Number Description Length, ft [m] Weight, lbm [kg]
274795 31⁄2-in. [88.90-mm] OD 8rd EUE—Carbon steel 0.8 [0.24] 25 [11.3]
1048339 31⁄2-in. [88.90-mm] OD 8rd EUE—Redalloy alloy 0.8 [0.24] 25 [11.3]
675 Series
Part Number Description Length, ft [m] Weight, lbm [kg]
1006261 5 ⁄2-in. [139.70-mm] OD 8rd LTC—Carbon steel
1
0.8 [0.24] 30 [13.6]
997353 51⁄2-in. [139.70-mm] OD 8rd LTC—Redalloy alloy 0.8 [0.24] 33 [15.0]
725 Series
Part Number Description Length, ft [m] Weight, lbm [kg]
1311125 5 ⁄2-in. [139.70-mm] OD 8rd LTC—Carbon steel
1
0.8 [0.24] 45 [20.4]
Return to Pumps
Return to Pumps
AN550 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Head
20 2.00 40
15 1.50 30
Head
(ft) Efficiency
10 1.00 20
Operating range
5 0.50 10
Power
0 0 0
0 100 200 300 400 500 600 700 800 900
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump AN550 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70 Hz
25
65 Hz
20 60 Hz
55 Hz
Head 15
(ft) 50 Hz
10
0.20 70 Hz
65 Hz
0.15
Power 60 Hz
(hp)
0.10 55 Hz
50 Hz
0.05
0 100 200 300 400 500 600 700 800 900 1,000 1,100
Capacity (B/D)
Return to Pumps
Return to Pumps
Pumps
Head
4.00 2.00 40
Efficiency
3.00 1.50 30
Head
(m)
2.00 1.00 20
Operating range
1.00 0.50 10
Power
0 0 0
0 25 50 75 100 125
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump AN550 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
8.00 70 Hz
7.00 65 Hz
6.00 60 Hz
5.00 55 Hz
Head
(m) 50 Hz
4.00
3.00
2.00
1.00
0.20 70 Hz
0.15 65 Hz
Power 60 Hz
(hp)
0.10 55 Hz
50 Hz
0.05
Return to Pumps
Return to Pumps
AN900 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
25 Efficiency 1.25 50
Head
20 1.00 40
Operating range
Head 15 0.75 30
(ft)
10 0.50 20
5 0.25 10
Power
0 0 0
0 250 500 750 1,000 1,250 1,500
Capacity (B ⁄ D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump AN900 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
25
70 Hz
20 65 Hz
60 Hz
Head 15
(ft) 55 Hz
50 Hz
10
70 Hz
0.20
65 Hz
0.15
60 Hz
Power
(hp) 55 Hz
0.10
50 Hz
0.05
Return to Pumps
Return to Pumps
Pumps
Head
4.00 1.00 40
Operating range
2.00 0.50 20
1.00 0.25 10
Power
0 0 0
0 25 50 75 100 125 150 175 200
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump AN900 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
8.00
7.00 70 Hz
6.00 65 Hz
60 Hz
5.00
Head
(m) 55 Hz
4.00
50 Hz
3.00
2.00
1.00
70 Hz
0.20
65 Hz
0.15 60 Hz
Power
(hp) 55 Hz
0.10
50 Hz
0.05
Return to Pumps
Return to Pumps
AN1200 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
25 Efficiency 1.25 50
Head
20 1.00 40
Operating range
Head 15 0.75 30
(ft)
10 0.50 20
5 0.25 10
Power
0 0 0
0 250 500 750 1,000 1,250 1,500 1,750 2,000
Capacity (B ⁄ D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump AN1200 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
25
70 Hz
65 Hz
20
60 Hz
Head 15 55 Hz
(ft)
50 Hz
10
0.35 70 Hz
0.30
65 Hz
0.25
60 Hz
Power 0.20
(hp) 55 Hz
0.15
50 Hz
0.10
0.05
0 250 500 750 1,000 1,250 1,500 1,750 2,000 2,250 2,500
Capacity (B/D)
Return to Pumps
Return to Pumps
Pumps
Head
4.00 1.00 40
Operating range
2.00 0.50 20
1.00 0.25 10
Power
0 0 0
0 25 50 75 100 125 150 175 200 225 250 275
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump AN1200 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
8.00
70 Hz
7.00
65 Hz
6.00
60 Hz
5.00
Head
55 Hz
(m)
4.00
50 Hz
3.00
2.00
1.00
0.35 70 Hz
0.30
65 Hz
0.25
60 Hz
Power 0.20
(hp) 55 Hz
0.15
50 Hz
0.10
0.05
Return to Pumps
Return to Pumps
AN1500 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 1,000–2,000 B/D Shaft brake-power limit Standard 125 hp
Nominal housing diameter 3.38 in. High strength 200 hp
Shaft diameter 0.688 in. Housing burst-pressure limit Standard Not applicable
Shaft cross-sectional area 0.371 in.2 Buttress 6,000 psi Power Efficiency
Min. casing size 4.500 in. Welded 6,000 psi (hp) (%)
20 Efficiency 2.00 40
Head
Operating range
15 1.50 30
Head
(ft)
10 1.00 20
5 0.50 10
Power
0 0 0
0 250 500 750 1,000 1,250 1,500 1,750 2,000 2,250 2,500 2,750
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump AN1500 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
22.50
70 Hz
20.00
65 Hz
17.50
60 Hz
15.00
Head 55 Hz
(ft) 12.50
50 Hz
10.00
7.50
5.00
2.50
0.50 70 Hz
0.45
0.40 65 Hz
0.35
0.30 60 Hz
Power
(hp) 0.25 55 Hz
0.20 50 Hz
0.15
0.10
0.05
Capacity (B/D)
Return to Pumps
Return to Pumps
Pumps
4.00 2.00 40
Head
Operating range
3.00 1.50 30
Head
(m) Efficiency
2.00 1.00 20
1.00 0.50 10
Power
0 0 0
0 50 100 150 200 250 300 350 400
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump AN1500 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70 Hz
6.00
65 Hz
5.00
60 Hz
4.00 55 Hz
Head 50 Hz
(m) 3.00
2.00
1.00
0.50 70 Hz
0.45
0.40 65 Hz
0.35
0.30 60 Hz
Power 0.25 55 Hz
(hp) 0.20 50 Hz
0.15
0.10
0.05
0 50 100 150 200 250 300 350 400 450 500 550
Capacity (m /d)
3
Return to Pumps
Return to Pumps
A2700N Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 1,800–3,400 B/D Shaft brake-power limit Standard 125 hp
Nominal housing diameter 3.38 in. High strength 200 hp
Shaft diameter 0.688 in. Housing burst-pressure limit Standard Not applicable
Shaft cross-sectional area 0.371 in.2 Buttress 6,000 psi Power Efficiency
Min. casing size 4.500 in. Welded 6,000 psi (hp) (%)
30 3.00 60
Operating range
25 2.50 50
Head
20 2.00 40
Head
(ft)
15 1.50 30
Efficiency
10 1.00 20
5 Power 0.50 10
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump A2700N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
30
70 Hz
25
65 Hz
20
60 Hz
Head
(ft) 55 Hz
15
50 Hz
10
0.70 70 Hz
0.60
65 Hz
0.50
60 Hz
Power 0.40
(hp) 55 Hz
0.30
50 Hz
0.20
0.10
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5,000
Capacity (B/D)
Return to Pumps
Return to Pumps
Pumps
6.00 3.00 60
5.00 2.50 50
Head
4.00 2.00 40
Head
(m) Efficiency
3.00 1.50 30
2.00 1.00 20
Operating range
1.00 0.50 10
Power
0 0 0
0 50 100 150 200 250 300 350 400 450 500 550
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump A2700N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
8.00
70 Hz
7.00
65 Hz
6.00
60 Hz
5.00
55 Hz
Head
(m)
4.00 50 Hz
3.00
2.00
1.00
0.70 70 Hz
0.60
65 Hz
0.50
60 Hz
Power 0.40
(hp) 55 Hz
0.30
50 Hz
0.20
0.10
Return to Pumps
Return to Pumps
D3050N Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 2,000–3,700 B/D Shaft brake-power limit Standard 256 hp
Nominal housing diameter 3.87 in. High strength 410 hp
Shaft diameter 0.875 in. Housing burst-pressure limit Standard Not applicable
Shaft cross-sectional area 0.601 in.2 Buttress 4,800 psi Power Efficiency
Min. casing size 5.5 in. Welded 4,800 psi (hp) (%)
Head
30 3.00 60
25 2.50 50
Efficiency
20 2.00 40
Head
(ft)
15 1.50 30
Operating range
10 1.00 20
Power
5 0.50 10
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump D3050N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
45
40
70 Hz
35
65 Hz
30
60 Hz
Head 25
(ft) 55 Hz
20
50 Hz
15
10
70 Hz
1.00
65 Hz
0.75 60 Hz
Power
(hp) 55 Hz
0.50
50 Hz
0.25
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5,000 5,500
Capacity (B/D)
Return to Pumps
Return to Pumps
Pumps
7.00 3.50 70
Head
6.00 3.00 60
5.00 2.50 50
Efficiency
Head 4.00 2.00 40
(m)
3.00 1.50 30
Operating range
2.00 1.00 20
0 0 0
0 100 200 300 400 500 600
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump D3050N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
12.50
70 Hz
10.00 65 Hz
60 Hz
Head 7.50
(m) 55 Hz
50 Hz
5.00
2.50
70 Hz
10.00
65 Hz
7.50 60 Hz
Power
55 Hz
(hp) 5.00
50 Hz
2.50
Return to Pumps
Return to Pumps
D3400N Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 2,400–4,400 B/D Shaft brake-power limit Standard 256 hp
Nominal housing diameter 3.87 in. High strength 410 hp
Shaft diameter 0.875 in. Housing burst-pressure limit Standard Not applicable
Shaft cross-sectional area 0.601 in.2 Buttress 4,800 psi Power Efficiency
Min. casing size 5.500 in. Welded Not applicable (hp) (%)
30 3.00 60
Head
Operating range
25 2.50 50
20 2.00 40
Head
(ft) Efficiency
15 1.50 30
10 1.00 20
Power
5 0.50 10
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump D3400N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
40
35
70 Hz
30
65 Hz
25
60 Hz
Head
(ft)
20 55 Hz
50 Hz
15
10
1.25 70 Hz
1.00 65 Hz
60 Hz
Power 0.75
(hp)
55 Hz
0.50 50 Hz
0.25
Return to Pumps
Return to Pumps
Pumps
Head
6.00 3.00 60
Operating range
5.00 2.50 50
4.00 2.00 40
Head Efficiency
(m)
3.00 1.50 30
2.00 1.00 20
1.00 0.50 10
Power
0 0 0
0 100 200 300 400 500 600 700
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump D3400N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70 Hz
10.00
65 Hz
60 Hz
7.50
Head 55 Hz
(m)
50 Hz
5.00
2.50
1.25 70 Hz
1.00 65 Hz
60 Hz
Power 0.75
(hp) 55 Hz
0.50 50 Hz
0.25
0 100 200 300 400 500 600 700 800 900 1,000
Capacity (m3/d)
Return to Pumps
Return to Pumps
D5850N Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 4,400–7,000 B/D Shaft brake-power limit Standard 256 hp
Nominal housing diameter 3.87 in. High strength 410 hp
Shaft diameter 0.875 in. Housing burst-pressure limit Standard Not applicable
Shaft cross-sectional area 0.601 in.2 Buttress 4,800 psi Power Efficiency
Min. casing size 5.500 in. Welded Not applicable (hp) (%)
35 3.50 70
Efficiency
30 3.00 60
Head Operating range
25 2.50 50
Head 20 2.00 40
(ft)
15 1.50 30
10 Power 1.00 20
5 0.50 10
0 0 0
0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump D5850N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
40
35
70 Hz
30 65 Hz
25 60 Hz
Head
(ft) 55 Hz
20
50 Hz
15
10
2.25 70 Hz
2.00
1.75 65 Hz
1.50
60 Hz
Power 1.25
(hp) 55 Hz
1.00
50 Hz
0.75
0.50
0.25
0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000
Capacity (B/D)
Return to Pumps
Return to Pumps
Pumps
7.00 3.50 70
6.00 3.00 60
Head
5.00 2.50 50
3.00 1.50 30
Operating range
2.00 1.00 20
Power
1.00 0.50 10
0 0 0
0 100 200 300 400 500 600 700 800 900 1,000 1,1 00
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump D5850N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70 Hz
10.00
65 Hz
7.50 60 Hz
Head 55 Hz
(m)
50 Hz
5.00
2.50
2.25 70 Hz
2.00
1.75 65 Hz
1.50
60 Hz
Power 1.25
(hp) 55 Hz
1.00
50 Hz
0.75
0.50
0.25
Return to Pumps
Return to Pumps
D475N Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
50 1.25 50
40 1.00 40
Operating range
Head
Head 30 0.75 30
(ft)
Efficiency
20 0.50 20
10 0.25 10
Power
0 0 0
0 100 200 300 400 500 600 700 800
Capacity (B ⁄ D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump D475N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70 Hz
40
65 Hz
35
60 Hz
30
55 Hz
25
Head
(ft) 50 Hz
20
15
10
70 Hz
0.25
65 Hz
0.20
60 Hz
Power 0.15
(hp) 55 Hz
0.10 50 Hz
0.05
0 100 200 300 400 500 600 700 800 900 1,000
Capacity (B/D)
Return to Pumps
Return to Pumps
Pumps
12.50 1.25 50
10.00 1.00 40
Operating range
Efficiency
Head 7.50 0.75 30
(m) Head
5.00 0.50 20
2.50 0.25 10
Power
0 0 0
0 10 20 30 40 50 60 70 80 90 100 110
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump D475N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70 Hz
12.50
65 Hz
10.00 60 Hz
55 Hz
Head
7.50
(m)
50 Hz
5.00
2.50
70 Hz
0.25
65 Hz
0.20
60 Hz
Power 0.15
(hp) 55 Hz
0.10 50 Hz
0.05
Return to Pumps
Return to Pumps
D725N Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
60 1.50 60
50 1.25 50
20 0.50 20
10 0.25 10
Power
0 0 0
0 100 200 300 400 500 600 700 800 900 1,000 1,100
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump D725N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70 Hz
40
65 Hz
35
60 Hz
30
55 Hz
25
Head
(ft) 50 Hz
20
15
10
70 Hz
0.30
65 Hz
0.25
0.20 60 Hz
Power
(hp) 55 Hz
0.15
50 Hz
0.10
0.05
Return to Pumps
Return to Pumps
Pumps
15.00 1.50 60
12.50 1.25 50
Efficiency
10.00 Operating range 1.00 40
Head
(m)
7.50 0.75 30
Head
5.00 0.50 20
2.50 0.25 10
Power
0 0 0
0 25 50 75 100 125 150
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump D725N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
12.50 70 Hz
65 Hz
10.00
60 Hz
Head 55 Hz
(m) 7.50
50 Hz
5.00
2.50
70 Hz
0.30
65 Hz
0.25
0.20 60 Hz
Power
(hp) 55 Hz
0.15
50 Hz
0.10
0.05
Return to Pumps
Return to Pumps
DN1100 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 600–1,350 B/D Shaft brake-power limit Standard 125 hp
Nominal housing diameter 4.00 in. High strength 200 hp
Shaft diameter 0.688 in. Housing burst-pressure limit Standard 5,000 psi
Shaft cross-sectional area 0.371 in.2 Buttress 6,000 psi Power Efficiency
Min. casing size 5.500 in. Welded 6,000 psi (hp) (%)
30 3.00 60
Head
25 2.50 50
20 2.00 40
Efficiency
Head
(ft)
Operating range
15 1.50 30
10 1.00 20
5 0.50 10
Power
0 0 0
0 250 500 750 1,000 1,250 1,500 1,750 2,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump DN1100 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
40
70 Hz
35
65 Hz
30
60 Hz
25
Head 55 Hz
(ft)
20 50 Hz
15
10
0.45 70 Hz
0.40
65 Hz
0.35
0.30 60 Hz
Power 0.25
(hp) 55 Hz
0.20
50 Hz
0.15
0.10
0.05
Return to Pumps
Return to Pumps
Pumps
6.00 3.00 60
Head
5.00 2.50 50
4.00 2.00 40
Head Operating range
(m)
3.00 1.50 30
Efficiency
2.00 1.00 20
1.00 0.50 10
Power
0 0 0
0 25 50 75 100 125 150 175 200 225
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump DN1100 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
12.50
70 Hz
10.00 65 Hz
60 Hz
Head
(m) 7.50
55 Hz
50 Hz
5.00
2.50
0.45 70 Hz
0.40
0.35 65 Hz
0.30 60 Hz
Power 0.25
(hp) 55 Hz
0.20
50 Hz
0.15
0.10
0.05
Return to Pumps
Return to Pumps
D1400N Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 960–1,700 B/D Shaft brake-power limit Standard 125 hp
Nominal housing diameter 4.00 in. High strength 200 hp
Shaft diameter 0.688 in. Housing burst-pressure limit Standard 5,000 psi
Shaft cross-sectional area 0.371 in.2 Buttress 6,000 psi Power Efficiency
Min. casing size 5.500 in. Welded 6,000 psi (hp) (%)
30 Head 3.00 60
25 2.50 50
20 2.00 40
Head Efficiency
(ft)
15 1.50 30
Operating range
10 1.00 20
5 0.50 10
Power
0 0 0
0 250 500 750 1,000 1,250 1,500 1,750 2,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump D1400N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
40
35 70 Hz
30 65 Hz
60 Hz
25
Head
(ft) 55 Hz
20
50 Hz
15
10
0.50 70 Hz
0.40 65 Hz
Power 60 Hz
0.30
(hp)
55 Hz
0.20 50 Hz
0.10
0 250 500 750 1,000 1,250 1,500 1,750 2,000 2,250 2,500
Capacity (B/D)
Return to Pumps
Return to Pumps
Pumps
Head
6.00 3.00 60
5.00 2.50 50
4.00 2.00 40
Head Efficiency
(m)
3.00 1.50 30
2.00 1.00 20
Operating range
1.00 0.50 10
Power
0 0 0
0 25 50 75 100 125 150 175 200 225 250 275
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump D1400N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
12.50
70 Hz
10.00
65 Hz
Head 60 Hz
7.50
(m)
55 Hz
50 Hz
5.00
2.50
0.50 70 Hz
0.40 65 Hz
60 Hz
Power 0.30
(hp) 55 Hz
0.20 50 Hz
0.10
Capacity (m3/d)
Return to Pumps
Return to Pumps
DN1750 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 1,200–2,050 B/D Shaft brake-power limit Standard 125 hp
Nominal housing diameter 4.00 in. High strength 200 hp
Shaft diameter 0.688 in. Housing burst-pressure limit Standard 5,000 psi
Shaft cross-sectional area 0.371 in.2 Buttress 6,000 psi Power Efficiency
Min. casing size 5.500 in. Welded 6,000 psi (hp) (%)
30 3.00 60
Head
Operating range
25 2.50 50
20 2.00 40
Head
Efficiency
(ft)
15 1.50 30
10 1.00 20
5 0.50 10
Power
0 0 0
0 250 500 750 1,000 1,250 1,500 1,750 2,000 2,250 2,500
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump DN1750 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
40
35
70 Hz
30 65 Hz
25 60 Hz
Head
(ft) 55 Hz
20
50 Hz
15
10
70 Hz
0.50
65 Hz
0.40
60 Hz
Power 0.30
(hp) 55 Hz
0.20 50 Hz
0.10
Return to Pumps
Return to Pumps
Pumps
Head
6.00 3.00 60
Operating range
5.00 2.50 50
4.00 2.00 40
Head Efficiency
(m)
3.00 1.50 30
2.00 1.00 20
1.00 0.50 10
Power
0 0 0
0 50 100 150 200 250 300 350
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump DN1750 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
12.50
70 Hz
10.00
65 Hz
Head 60 Hz
(m) 7.50
55 Hz
50 Hz
5.00
2.50
70 Hz
0.50
65 Hz
0.40
60 Hz
Power
(hp) 0.30
55 Hz
0.20 50 Hz
0.10
Return to Pumps
Return to Pumps
DN1800 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 1,200–2,400 B/D Shaft brake-power limit Standard 125 hp
Nominal housing diameter 4.00 in. High strength 200 hp
Shaft diameter 0.688 in. Housing burst-pressure limit Standard 5,000 psi
Shaft cross-sectional area 0.371 in.2 Buttress 6,000 psi Power Efficiency
Min. casing size 5.500 in. Welded 6,000 psi (hp) (%)
35 1.75 70
30 1.50 60
Head
Operating range
25 1.25 50
Head 20 1.00 40
(ft) Efficiency
15 0.75 30
10 0.50 20
Power
5 0.25 10
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump DN1800 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
40
35
70 Hz
30 65 Hz
25 60 Hz
Head
(ft) 55 Hz
20
50 Hz
15
10
0.50 70 Hz
0.40 65 Hz
Power 60 Hz
0.30
(hp)
55 Hz
0.20 50 Hz
0.10
Capacity (B/D)
Return to Pumps
Return to Pumps
Pumps
7.00 1.75 70
Head
6.00 1.50 60
Operating range
5.00 1.25 50
2.00 0.50 20
1.00 0.25 10
Power
0 0 0
0 50 100 150 200 250 300 350 400
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump DN1800 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
12.50
70 Hz
10.00
65 Hz
Head 60 Hz
(m) 7.50
55 Hz
50 Hz
5.00
2.50
0.50 70 Hz
0.40 65 Hz
Power 60 Hz
0.30
(hp)
55 Hz
0.20 50 Hz
0.10
0 50 100 150 200 250 300 350 400 450 500 550
Capacity (m3/d)
Return to Pumps
Return to Pumps
DN2150 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 1,300–2,600 B/D Shaft brake-power limit Standard 125 hp
Nominal housing diameter 4.00 in. High strength 200 hp
Shaft diameter 0.688 in. Housing burst-pressure limit Standard 5,000 psi
Shaft cross-sectional area 0.371 in.2 Buttress 6,000 psi Power Efficiency
Min. casing size 5.500 in. Welded 6,000 psi (hp) (%)
60 3.00 60
50 2.50 50
Efficiency
20 1.00 20
10 Power 0.50 10
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump DN2150 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
40 70 Hz
35 65 Hz
30 60 Hz
25 55 Hz
Head
(ft) 50 Hz
20
15
10
70 Hz
0.90
0.80
65 Hz
0.70
0.60 60 Hz
Power 0.50
(hp) 55 Hz
0.40
50 Hz
0.30
0.20
0.10
Return to Pumps
Return to Pumps
Pumps
15.00 1.50 60
12.50 1.25 50
Efficiency
10.00 1.00 40
Head Operating range
(m)
7.50 0.75 30
Head
5.00 0.50 20
Power
2.50 0.25 10
0 0 0
0 50 100 150 200 250 300 350 400 450
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump DN2150 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
12.50 70 Hz
65 Hz
10.00
60 Hz
Head 55 Hz
(m) 7.50
50 Hz
5.00
2.50
70 Hz
0.90
0.80
65 Hz
0.70
0.60 60 Hz
Power 0.50
(hp) 55 Hz
0.40
50 Hz
0.30
0.20
0.10
Return to Pumps
Return to Pumps
D2400N Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 1,500–3,200 B/D Shaft brake-power limit Standard 162 hp
Nominal housing diameter 4.00 in. High strength 245 hp
Shaft diameter 0.688 in. Housing burst-pressure limit Standard 5,000 psi
Shaft cross-sectional area 0.371 in.2 Buttress 6,000 psi Power Efficiency
Min. casing size 5.500 in. Welded 6,000 psi (hp) (%)
60 3.00 60
Efficiency
50 2.50 50
Operating range
40 2.00 40
Head
(ft) Head
30 1.50 30
20 1.00 20
Power
10 0.50 10
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump D2400N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
50
45
70 Hz
40
35 65 Hz
30 60 Hz
Head
(ft) 25 55 Hz
50 Hz
20
15
10
70 Hz
1.00
65 Hz
0.75
60 Hz
Power
(hp) 55 Hz
0.50
50 Hz
0.25
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5,000
Capacity (B/D)
Return to Pumps
Return to Pumps
Pumps
15.00 3.00 60
Efficiency
12.50 2.50 50
Operating range
10.00 2.00 40
Head
(m)
7.50 Head 1.50 30
5.00 1.00 20
2.50 0.50 10
Power
0 0 0
0 50 100 150 200 250 300 350 400 450 500 550
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump D2400N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
15.00
12.50 70 Hz
65 Hz
10.00
60 Hz
Head
(m)
55 Hz
7.50
50 Hz
5.00
2.50
70 Hz
1.00
65 Hz
0.75
60 Hz
Power
(hp) 55 Hz
0.50
50 Hz
0.25
Return to Pumps
Return to Pumps
DN3000 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 2,100–3,700 B/D Shaft brake-power limit Standard 256 hp
Nominal housing diameter 4.00 in. High strength 410 hp
Shaft diameter 0.875 in. Housing burst-pressure limit Standard 5,000 psi
Shaft cross-sectional area 0.601 in.2 Buttress 6,000 psi Power Efficiency
Min. casing size 5.500 in. Welded 6,000 psi (hp) (%)
30 Head 3.00 60
Operating range
25 2.50 50
20 2.00 40
Head Efficiency
(ft)
15 1.50 30
10 1.00 20
Power
5 0.50 10
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump DN3000 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
35
70 Hz
30 65 Hz
25 60 Hz
55 Hz
Head 20
(ft) 50 Hz
15
10
1.00
70 Hz
0.90
65 Hz
0.80
0.70 60 Hz
0.60
Power 55 Hz
0.50
(hp)
0.40 50 Hz
0.30
0.20
0.10
Return to Pumps
Return to Pumps
Pumps
Head
6.00 3.00 60
Operating range
5.00 2.50 50
4.00 2.00 40
Efficiency
Head
(m)
3.00 1.50 30
2.00 1.00 20
1.00 0.50 10
Power
0 0 0
0 100 200 300 400 500 600 700
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump DN3000 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70 Hz
10.00
65 Hz
60 Hz
7.50
Head 55 Hz
(m)
50 Hz
5.00
2.50
1.00
70 Hz
0.90
65 Hz
0.80
0.70 60 Hz
0.60
Power 55 Hz
(hp) 0.50
0.40 50 Hz
0.30
0.20
0.10
0 100 200 300 400 500 600 700 800 900 1,000
Capacity (m3/d)
Return to Pumps
Return to Pumps
DN3100 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 2,100–3,900 B/D Shaft brake-power limit Standard 256 hp
Nominal housing diameter 4.00 in. High strength 410 hp
Shaft diameter 0.875 in. Housing burst-pressure limit Standard 5,000 psi
Shaft cross-sectional area 0.601 in.2 Buttress 6,000 psi Power Efficiency
Min. casing size 5.500 in. Welded 6,000 psi (hp) (%)
30 Head 3.00 60
Operating range
25 2.50 50
20 2.00 40
Head Efficiency
(ft)
15 1.50 30
10 1.00 20
Power
5 0.50 10
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump DN3100 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
35
70 Hz
30 65 Hz
25 60 Hz
55 Hz
Head 20
(ft)
50 Hz
15
10
1.00 70 Hz
0.90
0.80 65 Hz
0.70
60 Hz
0.60
Power 0.50 55 Hz
(hp)
0.40 50 Hz
0.30
0.20
0.10
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5,000 5,500
Capacity (B/D)
Return to Pumps
Return to Pumps
Pumps
Head
6.00 3.00 60
Operating range
5.00 2.50 50
4.00 2.00 40
Head Efficiency
(m)
3.00 1.50 30
2.00 1.00 20
1.00 0.50 10
Power
0 0 0
0 100 200 300 400 500 600 700
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump DN3100 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70 Hz
10.00
65 Hz
60 Hz
7.50
Head 55 Hz
(m)
50 Hz
5.00
2.50
1.00 70 Hz
0.90
0.80 65 Hz
0.70
60 Hz
0.60
Power
0.50 55 Hz
(hp)
0.40 50 Hz
0.30
0.20
0.10
Return to Pumps
Return to Pumps
D4300N Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 3,500–5,400 B/D Shaft brake-power limit Standard 256 hp
Nominal housing diameter 4.00 in. High strength 410 hp
Shaft diameter 0.875 in. Housing burst-pressure limit Standard 5,000 psi
Shaft cross-sectional area 0.601 in.2 Buttress 6,000 psi Power Efficiency
Min. casing size 5.500 in. Welded 6,000 psi (hp) (%)
35 3.50 70
Head
25 2.50 50
Head 20 2.00 40
(ft)
15 1.50 30
10 1.00 20
Power
5 0.50 10
0 0 0
0 1,000 2,000 3,000 4,000 5,000 6,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump D4300N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
35
70 Hz
30
65 Hz
25
60 Hz
Head 20 55 Hz
(ft)
50 Hz
15
10
1.50 70 Hz
1.25
65 Hz
1.00
Power 60 Hz
(hp)
0.75 55 Hz
50 Hz
0.50
0.25
Capacity (B/D)
Return to Pumps
Return to Pumps
Pumps
7.00 3.50 70
Efficiency
6.00 3.00 60
Head Operating range
5.00 2.50 50
3.00 1.50 30
2.00 1.00 20
0 0 0
0 100 200 300 400 500 600 700 800
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump D4300N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
10.00 70 Hz
65 Hz
7.50 60 Hz
Head
(m) 55 Hz
5.00 50 Hz
2.50
1.50 70 Hz
1.25
65 Hz
1.00
60 Hz
Power
(hp) 0.75 55 Hz
50 Hz
0.50
0.25
Return to Pumps
Return to Pumps
D5800N Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 4,400–7,000 B/D Shaft brake-power limit Standard 255 hp
Nominal housing diameter 4.00 in. High strength 410 hp
Shaft diameter 0.875 in. Housing burst-pressure limit Standard 5,000 psi
Shaft cross-sectional area 0.601 in.2 Buttress 6,000 psi Power Efficiency
Min. casing size 5.500 in. Welded 6,000 psi (hp) (%)
35 3.50 70
Efficiency
30 3.00 60
Head Operating range
25 2.50 50
Head 20 2.00 40
(ft)
15 1.50 30
10 Power 1.00 20
5 0.50 10
0 0 0
0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump D5800N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
40
35
70 Hz
30 65 Hz
25 60 Hz
Head
(ft) 55 Hz
20
50 Hz
15
10
2.25 70 Hz
2.00
1.75 65 Hz
1.50
60 Hz
Power 1.25
(hp) 55 Hz
1.00
50 Hz
0.75
0.50
0.25
0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000
Capacity (B/D)
Return to Pumps
Return to Pumps
Pumps
7.00 3.50 70
6.00 3.00 60
Head
5.00 2.50 50
3.00 1.50 30
Operating range
2.00 1.00 20
Power
1.00 0.50 10
0 0 0
0 100 200 300 400 500 600 700 800 900 1,000 1,1 00
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump D5800N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70 Hz
10.00
65 Hz
7.50 60 Hz
Head 55 Hz
(m)
50 Hz
5.00
2.50
2.25 70 Hz
2.00
1.75 65 Hz
1.50
60 Hz
Power 1.25
(hp) 55 Hz
1.00
50 Hz
0.75
0.50
0.25
Return to Pumps
Return to Pumps
GN1600 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
60 3.00 60
Head
50 2.50 50
40 2.00 40
Efficiency
Head
(ft)
30 Operating range 1.50 30
20 1.00 20
Power
10 0.50 10
0 0 0
0 250 500 750 1,000 1,250 1,500 1,750 2,000 2,250 2,500 2,750
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump GN1600 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70 Hz
70
65 Hz
60
60 Hz
50
55 Hz
40 50 Hz
Head
(ft)
30
20
10
70 Hz
1.50
1.25 65 Hz
1.00 60 Hz
Power
(hp) 0.75 55 Hz
0.50
50 Hz
0.25
Capacity (B/D)
Return to Pumps
Return to Pumps
Pumps
15.00 3.00 60
10.00 2.00 40
Head
(m)
7.50 1.50 30
Efficiency
5.00 1.00 20
0 0 0
0 50 100 150 200 250 300 350
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump GN1600 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
22.50 70 Hz
20.00
65 Hz
17.50
60 Hz
15.00
55 Hz
Head 12.50
(m) 50 Hz
10.00
7.50
5.00
2.50
70 Hz
1.50
1.25 65 Hz
1.00 60 Hz
Power
0.75 55 Hz
(hp)
0.50
50 Hz
0.25
Return to Pumps
Return to Pumps
GN2100 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 1,650–2,700 B/D Shaft brake-power limit Standard 256 hp
Nominal housing diameter 5.13 in. High strength 410 hp
Shaft diameter 0.875 in. Housing burst-pressure limit Standard 5,000 psi
Shaft cross-sectional area 0.601 in.2 Buttress 6,000 psi Power Efficiency
Min. casing size 6.625 in. Welded 6,000 psi (hp) (%)
60 3.00 60
Head
50 2.50 50
40 2.00 40
Head
(ft) Efficiency
30 1.50 30
20 1.00 20
Power
10 0.50 10
Operating range
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump GN2100 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70
70 Hz
60 65 Hz
50 60 Hz
55 Hz
Head 40
(ft)
50 Hz
30
20
10
1.75 70 Hz
1.50
65 Hz
1.25
60 Hz
Power 1.00
(hp) 55 Hz
0.75
50 Hz
0.50
0.25
Return to Pumps
Return to Pumps
Pumps
15.00 3.00 60
Operating range
12.50 2.50 50
Head
10.00 2.00 40
Head
(m)
7.50 1.50 30
Efficiency
5.00 1.00 20
0 0 0
0 50 100 150 200 250 300 350 400 450
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump GN2100 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
22.50
70 Hz
20.00
65 Hz
17.50
60 Hz
15.00
Head 55 Hz
12.50
(m)
50 Hz
10.00
7.50
5.00
2.50
1.75 70 Hz
1.50
65 Hz
1.25
60 Hz
Power 1.00
(hp) 55 Hz
0.75
50 Hz
0.50
0.25
Return to Pumps
Return to Pumps
GN3200 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 2,200–4,100 B/D Shaft brake-power limit Standard 256 hp
Nominal housing diameter 5.13 in. High strength 410 hp
Shaft diameter 0.875 in. Housing burst-pressure limit Standard 5,000 psi
Shaft cross-sectional area 0.601 in.2 Buttress 6,000 psi Power Efficiency
Min. casing size 6.625 in. Welded 6,000 psi (hp) (%)
60 3.00 60
Head
50 2.50 50
40 2.00 40
Head Efficiency
(ft)
30 1.50 30
Power
20 1.00 20
10 0.50 10
Operating range
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5,000 5,500
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump GN3200 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70
70 Hz
60
65 Hz
50 60 Hz
Head 55 Hz
40
(ft)
50 Hz
30
20
10
70 Hz
2.25
2.00
65 Hz
1.75
1.50 60 Hz
Power 1.25
55 Hz
(hp) 1.00
50 Hz
0.75
0.50
0.25
Return to Pumps
Return to Pumps
Pumps
15.00 3.00 60
12.50 2.50 50
Head
Operating range
10.00 2.00 40
Head
(m)
7.50 1.50 30
Efficiency
5.00 1.00 20
Power
2.50 0.50 10
0 0 0
0 100 200 300 400 500 600 700
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump GN3200 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
22.50
20.00 70 Hz
17.50 65 Hz
15.00 60 Hz
Head 12.50 55 Hz
(m)
50 Hz
10.00
7.50
5.00
2.50
70 Hz
2.25
2.00
65 Hz
1.75
1.50 60 Hz
Power 1.25
55 Hz
(hp) 1.00
50 Hz
0.75
0.50
0.25
0 100 200 300 400 500 600 700 800 900 1,000
Capacity (m /d)
3
Return to Pumps
Return to Pumps
GN4000 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 3,200–4,800 B/D Shaft brake-power limit Standard 375 hp
Nominal housing diameter 5.13 in. High strength 600 hp
Shaft diameter 1.000 in. Housing burst-pressure limit Standard 5,000 psi
Shaft cross-sectional area 0.785 in.2 Buttress 6,000 psi Power Efficiency
Min. casing size 6.625 in. Welded 6,000 psi (hp) (%)
60 Efficiency 3.00 60
40 2.00 40
Head
(ft)
30 Power 1.50 30
20 1.00 20
10 0.50 10
0 0 0
0 1,000 2,000 3,000 4,000 5,000 6,000 7,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump GN4000 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70
60
70 Hz
50 65 Hz
60 Hz
Head 40
(ft) 55 Hz
30 50 Hz
20
10
2.25 70 Hz
2.00
65 Hz
1.75
1.50 60 Hz
Power 1.25
55 Hz
(hp) 1.00
50 Hz
0.75
0.50
0.25
Return to Pumps
Return to Pumps
Pumps
15.00 3.00 60
Efficiency
12.50 2.50 50
Operating range
Head
10.00 2.00 40
Head
(m)
7.50 1.50 30
5.00 1.00 20
Power
2.50 0.50 10
0 0 0
0 100 200 300 400 500 600 700 800 900
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump GN4000 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
20.00
17.50 70 Hz
15.00 65 Hz
60 Hz
12.50
Head
55 Hz
(m)
10.00
50 Hz
7.50
5.00
2.50
2.25 70 Hz
2.00
65 Hz
1.75
1.50 60 Hz
Power 1.25
55 Hz
(hp) 1.00
50 Hz
0.75
0.50
0.25
Return to Pumps
Return to Pumps
GN5200 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 3,900–6,600 B/D Shaft brake-power limit Standard 375 hp
Nominal housing diameter 5.13 in. High strength 600 hp
Shaft diameter 1.000 in. Housing burst-pressure limit Standard 5,000 psi
Shaft cross-sectional area 0.785 in.2 Buttress 6,000 psi Power Efficiency
Min. casing size 6.625 in. Welded 6,000 psi (hp) (%)
Head
60 6.00 60
50 5.00 50
40 4.00 40
Head Efficiency
(ft)
30 3.00 30
20 Power 2.00 20
Operating range
10 1.00 10
0 0 0
0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump GN5200 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
60
50 70 Hz
65 Hz
40
60 Hz
Head
(ft)
30 55 Hz
50 Hz
20
10
70 Hz
2.50
65 Hz
2.00
60 Hz
Power 1.50
(hp) 55 Hz
1.00 50 Hz
0.50
0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000
Capacity (B/D)
Return to Pumps
Return to Pumps
Pumps
15.00 3.00 60
Efficiency
12.50 2.50 50
Operating range
2.50 0.50 10
0 0 0
0 100 200 300 400 500 600 700 800 900 1,000 1,100
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump GN5200 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
17.50
15.00 70 Hz
65 Hz
12.50
60 Hz
Head
(m) 10.00
55 Hz
50 Hz
7.50
5.00
2.50
70 Hz
2.50
65 Hz
2.00
60 Hz
Power 1.50
(hp) 55 Hz
1.00 50 Hz
0.50
Return to Pumps
Return to Pumps
G6200N Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 4,500–8,000 B/D Shaft brake-power limit Standard 375 hp
Nominal housing diameter 5.13 in. High strength 600 hp
Shaft diameter 1.00 in. Housing burst-pressure limit Standard 5,000 psi
Shaft cross-sectional area 0.785 in.2 Buttress 6,000 psi Power Efficiency
Min. casing size 6.625 in. Welded 6,000 psi (hp) (%)
70 7.00 70
60 6.00 60
Efficiency
Head Operating range
50 5.00 50
Head 40 4.00 40
(ft)
30 3.00 30
20 Power 2.00 20
10 1.00 10
0 0 0
0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump G6200N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70
60
70 Hz
50 65 Hz
60 Hz
40
Head 55 Hz
(ft)
30 50 Hz
20
10
3.50 70 Hz
3.00
65 Hz
2.50
60 Hz
2.00
Power 55 Hz
(hp) 1.50
50 Hz
1.00
0.50
0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000 11,000
Capacity (B/D)
Return to Pumps
Return to Pumps
Pumps
17.50 3.50 70
15.00 3.00 60
Efficiency
12.50 2.50 50
Head Operating range
Head 10.00 2.00 40
(m)
7.50 1.50 30
Power
5.00 1.00 20
2.50 0.50 10
0 0 0
0 250 500 750 1,000 1,250
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump G6200N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
20.00
17.50 70 Hz
15.00 65 Hz
60 Hz
12.50
Head
55 Hz
(m)
10.00
50 Hz
7.50
5.00
2.50
3.50 70 Hz
3.00
65 Hz
2.50
60 Hz
Power 2.00
(hp) 55 Hz
1.50
50 Hz
1.00
0.50
Return to Pumps
Return to Pumps
GN7000 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 5,000–9,000 B/D Shaft brake-power limit Standard 375 hp
Nominal housing diameter 5.13 in. High strength 600 hp
Shaft diameter 1.000 in. Housing burst-pressure limit Standard 5,000 psi
Shaft cross-sectional area 0.785 in.2 Buttress 6,000 psi Power Efficiency
Min. casing size 6.625 in. Welded 6,000 psi (hp) (%)
60 15.00 60
Efficiency
40 10.00 40
Head
(ft)
30 7.50 30
20 5.00 20
10 Power 2.50 10
0 0 0
0 2,500 5,000 7,500 10,000 12,500
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump GN7000 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
60
70 Hz
50
65 Hz
60 Hz
40
Head 55 Hz
(ft)
30 50 Hz
20
10
70 Hz
4.00
3.50 65 Hz
3.00
60 Hz
2.50
Power 55 Hz
(hp) 2.00
1.50 50 Hz
1.00
0.50
Return to Pumps
Return to Pumps
Pumps
15.00 6.00 60
Efficiency
12.50 5.00 50
Operating range
Head
10.00 4.00 40
Head
(m)
7.50 3.00 30
5.00 2.00 20
Power
2.50 1.00 10
0 0 0
0 250 500 750 1,000 1,250 1,500 1,750
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump GN7000 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
17.50
70 Hz
15.00 65 Hz
12.50 60 Hz
Head 55 Hz
(m) 10.00
50 Hz
7.50
5.00
2.50
70 Hz
4.00
3.50 65 Hz
3.00
60 Hz
2.50
Power
(hp) 2.00 55 Hz
1.50 50 Hz
1.00
0.50
Return to Pumps
Return to Pumps
GN10000 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 7,000–12,000 B/D Shaft brake-power limit Standard 637 hp
Nominal housing diameter 5.13 in. High strength 1,019hp
Shaft diameter 1.188 in. Housing burst-pressure limit Standard 5,000 psi
Shaft cross-sectional area 1.108 in.2 Buttress 6,000 psi Power Efficiency
Min. casing size 6.625 in. Welded 6,000 psi (hp) (%)
70 17.50 70
Efficiency
60 15.00 60
Operating range
50 12.50 50
Head Head
40 10.00 40
(ft)
30 7.50 30
20 5.00 20
Power
10 2.50 10
0 0 0
0 2,500 5,000 7,500 10,000 12,500 15,000 17,500 20,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump GN10000 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
50
70 Hz
65 Hz
40
60 Hz
Head 30 55 Hz
(ft)
50 Hz
20
10
5.00 70 Hz
4.50
4.00 65 Hz
3.50
60 Hz
3.00
Power
(hp) 2.50 55 Hz
2.00 50 Hz
1.50
1.00
0.50
Return to Pumps
Return to Pumps
Pumps
17.50 7.00 70
Efficiency
15.00 6.00 60
Operating range
12.50 5.00 50
5.00 2.00 20
Power
2.50 1.00 10
0 0 0
0 250 500 750 1,000 1,250 1,500 1,750 2,000 2,250
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump GN10000 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
17.50
15.00 70 Hz
65 Hz
12.50
60 Hz
Head
(m) 10.00
55 Hz
7.50 50 Hz
5.00
2.50
5.00 70 Hz
4.50
4.00 65 Hz
3.50
60 Hz
3.00
Power
2.50 55 Hz
(hp)
2.00 50 Hz
1.50
1.00
0.50
Return to Pumps
Return to Pumps
SN2600 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 1,600–3,200 B/D Shaft brake-power limit Standard 256 hp
Nominal housing diameter 5.38 in. High strength 410 hp
Shaft diameter 0.875 in. Housing burst-pressure limit Standard Not applicable
Shaft cross-sectional area 0.601 in.2 Buttress 6,000 psi Power Efficiency
Min. casing size 7.000 in. Welded 6,000 psi (hp) (%)
Head
60 3.00 60
50 2.50 50
40 2.00 40
Efficiency
Head
(ft)
30 1.50 30
20 Power 1.00 20
Operating range
10 0.50 10
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump SN2600 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
80
70 Hz
70
65 Hz
60
60 Hz
50 55 Hz
Head
(ft) 50 Hz
40
30
20
10
2.25 70 Hz
2.00
65 Hz
1.75
1.50 60 Hz
Power 1.25
(hp) 55 Hz
1.00
0.75 50 Hz
0.50
0.25
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5,000
Capacity (B/D)
Return to Pumps
Return to Pumps
Pumps
15.00 3.00 60
10.00 2.00 40
Head
Efficiency
(m)
7.50 1.50 30
5.00 1.00 20
Power
2.50 0.50 10
0 0 0
0 50 100 150 200 250 300 350 400 450 500 550
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump SN2600 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
25.00
70 Hz
22.50
65 Hz
20.00
17.50 60 Hz
15.00 55 Hz
Head
(m) 12.50 50 Hz
10.00
7.50
5.00
2.50
2.25 70 Hz
2.00
65 Hz
1.75
1.50 60 Hz
Power 1.25
(hp) 55 Hz
1.00
50 Hz
0.75
0.50
0.25
Return to Pumps
Return to Pumps
SN3600 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 2,400–4,600 B/D Shaft brake-power limit Standard 256 hp
Nominal housing diameter 5.38 in. High strength 410 hp
Shaft diameter 0.875 in. Housing burst-pressure limit Standard Not applicable
Shaft cross-sectional area 0.601 in.2 Buttress 6,000 psi Power Efficiency
Min. casing size 7.000 in. Welded 6,000 psi (hp) (%)
70 7.00 70
Head
60 6.00 60
50 5.00 50
Efficiency
Head 40 4.00 40
(ft)
Operating range
30 3.00 30
20 2.00 20
Power
10 1.00 10
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5,000 5,500
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump SN3600 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70 Hz
80
65 Hz
70
60 Hz
60
55 Hz
50
Head
50 Hz
(ft)
40
30
20
10
3.00 70 Hz
2.50 65 Hz
2.00 60 Hz
Power
(hp) 1.50 55 Hz
50 Hz
1.00
0.50
Return to Pumps
Return to Pumps
Pumps
17.50 3.50 70
Efficiency
15.00 3.00 60
Head Operating range
12.50 2.50 50
7.50 1.50 30
5.00 1.00 20
Power
2.50 0.50 10
0 0 0
0 100 200 300 400 500 600 700 800
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump SN3600 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70 Hz
25.00
22.50 65 Hz
20.00
60 Hz
17.50
55 Hz
15.00
Head
(m) 50 Hz
12.50
10.00
7.50
5.00
2.50
3.00 70 Hz
2.50 65 Hz
2.00 60 Hz
Power
(hp) 1.50 55 Hz
50 Hz
1.00
0.50
0 100 200 300 400 500 600 700 800 900 1,000
Capacity (m /d)
3
Return to Pumps
Return to Pumps
S5000N Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 4,000–5,400 B/D Shaft brake-power limit Standard 375 hp
Nominal housing diameter 5.38 in. High strength 600 hp
Shaft diameter 1.000 in. Housing burst-pressure limit Standard Not applicable
Shaft cross-sectional area 0.785 in.2 Buttress 6,000 psi Power Efficiency
Min. casing size 7.000 in. Welded 6,000 psi (hp) (%)
70 7.00 70
Head
Efficiency
60 6.00 60
Operating range
50 5.00 50
Head 40 4.00 40
(ft)
30 3.00 30
Power
20 2.00 20
10 1.00 10
0 0 0
0 1,000 2,000 3,000 4,000 5,000 6,000 7,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump S5000N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
90
80
70 70 Hz
65 Hz
60
60 Hz
Head 50
(ft)
55 Hz
40
50 Hz
30
20
10
70 Hz
3.00
2.50 65 Hz
2.00 60 Hz
Power
(hp) 1.50 55 Hz
50 Hz
1.00
0.50
Return to Pumps
Return to Pumps
Pumps
17.50 3.50 70
Efficiency
15.00 3.00 60
Head
Operating range
12.50 2.50 50
7.50 1.50 30
Power
5.00 1.00 20
2.50 0.50 10
0 0 0
0 100 200 300 400 500 600 700 800 900 1,000
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump S5000N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
25
70 Hz
20
65 Hz
60 Hz
Head 15
(m) 55 Hz
50 Hz
10
70 Hz
3.00
2.50 65 Hz
2.00 60 Hz
Power
(hp) 1.50 55 Hz
50 Hz
1.00
0.50
Return to Pumps
Return to Pumps
S6000N Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 3,500–7,800 B/D Shaft brake-power limit Standard 487 hp
S6000N Pump
70 17.5 70
Head
60 15.0 60
Efficiency
50 12.5 50
Head 40 10.0 40
(ft)
Operating range
30 7.5 30
20 5.0 20
10 Power 2.5 10
0 0 0
0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump S6000N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
90
70 Hz
80
65 Hz
70
60 Hz
60
Head 55 Hz
50
(ft)
50 Hz
40
30
20
10
5.00 70 Hz
4.50
4.00 65 Hz
3.50
60 Hz
3.00
Power
2.50 55 Hz
(hp)
2.00 50 Hz
1.50
1.00
0.50
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 464–1,033 m3⁄d Shaft brake-power limit Standard 406 hp
S6000N Pump
17.50 7.00 70
15.00 6.00 60
Head Operating range
12.50 5.00 50
7.50 3.00 30
5.00 2.00 20
Power
2.50 1.00 10
0 0 0
0 250 500 750 1,000 1,250 1,500
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump S6000N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70 Hz
25
65 Hz
20
60 Hz
55 Hz
Head 15
(m)
50 Hz
10
5.00 70 Hz
4.50
4.00 65 Hz
3.50
60 Hz
3.00
Power
2.50 55 Hz
(hp)
2.00 50 Hz
1.50
1.00
0.50
Return to Pumps
Return to Pumps
SN8500 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 6,000–11,000 B/D Shaft brake-power limit Standard 375 hp
SN8500 Pump
70 17.50 70
60 Efficiency 15.00 60
Head Operating range
50 12.50 50
Head
(ft) 40 10.00 40
30 7.50 30
20 5.00 20
Power
10 2.50 10
0 0 0
0 2,500 5,000 7,500 10,000 12,500 15,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump SN8500 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
80
70
70 Hz
60
65 Hz
50
Head 60 Hz
(ft)
40 55 Hz
50 Hz
30
20
10
5.00 70 Hz
4.50
4.00 65 Hz
3.50
60 Hz
3.00
Power
(hp) 2.50 55 Hz
2.00 50 Hz
1.50
1.00
0.50
Return to Pumps
Return to Pumps
Pumps
17.50 7.00 70
Efficiency
15.00 6.00 60
7.50 3.00 30
5.00 2.00 20
Power
2.50 1.00 10
0 0 0
0 250 500 750 1,000 1,250 1,500 1,750 2,000
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump SN8500 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
25.00
22.50
20.00
70 Hz
17.50
65 Hz
15.00
Head 60 Hz
(m)
12.50
55 Hz
10.00 50 Hz
7.50
5.00
2.50
5.00 70 Hz
4.50
4.00 65 Hz
3.50
60 Hz
3.00
Power
(hp) 2.50 55 Hz
2.00 50 Hz
1.50
1.00
0.50
0 250 500 750 1,000 1,250 1,500 1,750 2,000 2,250 2,500 2,750
Capacity (m /d)
3
Return to Pumps
Return to Pumps
S8900N Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 4,000–11,000 B/D Shaft brake-power limit Standard 375 hp
S8900N Pump
70 17.50 70
60 Head 15.00 60
Head
(ft) 40 10.00 40
Efficiency
30 7.50 30
20 5.00 20
Power
10 2.50 10
0 0 0
0 2,500 5,000 7,500 10,000 12,500 15,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump S8900N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
80
70
70 Hz
60
65 Hz
50
60 Hz
Head
(ft)
40 55 Hz
50 Hz
30
20
10
70 Hz
5.00
65 Hz
4.00
60 Hz
Power 3.00
(hp) 55 Hz
2.00 50 Hz
1.00
Return to Pumps
Return to Pumps
Pumps
17.50 7.00 70
15.00 6.00 60
Efficiency
7.50 3.00 30
5.00 2.00 20
Power
2.50 1.00 10
0 0 0
0 250 500 750 1,000 1,250 1,500 1,750 2,000
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump S8900N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
25.00
22.50
20.00
70 Hz
17.50
65 Hz
15.00
Head 60 Hz
(m)
12.50 55 Hz
10.00 50 Hz
7.50
5.00
2.50
70 Hz
5.00
65 Hz
4.00
60 Hz
Power 3.00
(hp) 55 Hz
2.00 50 Hz
1.00
0 250 500 750 1,000 1,250 1,500 1,750 2,000 2,250 2,500 2,750
Capacity (m /d)
3
Return to Pumps
Return to Pumps
HN13500 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 5,000–18,000 B/D Shaft brake-power limit Standard 375 hp
Nominal housing diameter 5.38 in. High strength 600 hp
Shaft diameter 1.000 in. Housing burst-pressure limit Standard 3,000 psi
Shaft cross-sectional area 0.785 in.2 Buttress Not applicable Power Efficiency
Min. casing size 7.000 in. Welded 3,600 psi (hp) (%)
Head
60 15.00 60
50 12.50 50
40 10.00 40
Head Efficiency
(ft)
30 7.50 30
20 Power 5.00 20
Operating range
10 2.50 10
0 0 0
0 2,500 5,000 7,500 10,000 12,500 15,000 17,500 20,000 22,500
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump HN13500 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70 Hz
80
65 Hz
70
60 Hz
60
55 Hz
50
Head 50 Hz
(ft)
40
30
20
10
10.00
70 Hz
9.00
8.00 65 Hz
7.00
6.00 60 Hz
Power
5.00 55 Hz
(hp)
4.00
50 Hz
3.00
2.00
1.00
0 2,500 5,000 7,500 10,000 12,500 15,000 17,500 20,000 22,500 25,000
Capacity (B/D)
Return to Pumps
Return to Pumps
Pumps
15.00 15.00 60
Head
10.00 10.00 40
Head
(m) Efficiency
7.50 7.50 30
5.00 5.00 20
Power
2.50 2.50 10
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump HN13500 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70 Hz
25.00
65 Hz
22.50
20.00 60 Hz
17.50
55 Hz
15.00
Head 50 Hz
(m) 12.50
10.00
7.50
5.00
2.50
10.00
70 Hz
9.00
8.00 65 Hz
7.00
6.00 60 Hz
Power
5.00 55 Hz
(hp)
4.00
50 Hz
3.00
2.00
1.00
Return to Pumps
Return to Pumps
HN15000 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 12,000–18,000 B/D Shaft brake-power limit Standard 375 hp
Nominal housing diameter 5.63 in. High strength 600 hp
Shaft diameter 1.000 in. Housing burst-pressure limit Standard 3,000 psi
Shaft cross-sectional area 0.785 in.2 Buttress Not applicable Power Efficiency
Min. casing size 7.000 in. Welded 3,600 psi (hp) (%)
Head
60 15.00 60
Operating range
50 12.50 50
40 10.00 40
Efficiency
Head
(ft)
30 7.50 30
Power
20 5.00 20
10 2.50 10
0 0 0
0 2,500 5,000 7,500 10,000 12,500 15,000 17,500 20,000 22,500 25,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump HN15000 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
90
80
70
70 Hz
60
65 Hz
Head 50
(ft) 60 Hz
40 55 Hz
50 Hz
30
20
10
70 Hz
10.00
65 Hz
7.50 60 Hz
Power
(hp) 55 Hz
5.00
50 Hz
2.50
Return to Pumps
Return to Pumps
Pumps
Operating range
12.50 12.50 50
10.00 10.00 40
Efficiency
Head
(m)
7.50 7.50 30
5.00 5.00 20
Power
2.50 2.50 10
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump HN15000 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
25
20
70 Hz
65 Hz
Head 15 60 Hz
(m)
55 Hz
10 50 Hz
70 Hz
10.00
65 Hz
7.50 60 Hz
Power
(hp) 55 Hz
5.00
50 Hz
2.50
Return to Pumps
Return to Pumps
H15500N Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 11,000–20,000 B/D Shaft brake-power limit Standard 637 hp
Nominal housing diameter 5.63 in. High strength 1,019 hp
Shaft diameter 1.188 in. Housing burst-pressure limit Standard 3,000 psi
Shaft cross-sectional area 1.108 in.2 Buttress Not applicable Power Efficiency
Min. casing size 7.000 in. Welded Not applicable (hp) (%)
70 35 70
60 Head 30 60
50 25 50
Head 40 Efficiency 20 40
(ft)
Operating range
30 15 30
20 10 20
Power
10 5 10
0 0 0
0 2,500 5,000 7,500 10,000 12,500 15,000 17,500 20,000 22,500
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump H15500N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70 70 Hz
65 Hz
60
60 Hz
50
55 Hz
Head
(m) 40
50 Hz
30
20
10
12.50
70 Hz
10.00
65 Hz
Power 7.50 60 Hz
(hp)
55 Hz
5.00
50 Hz
2.50
Return to Pumps
Return to Pumps
Pumps
17.50 17.50 70
15.00 15.00 60
Operating range
5.00 5.00 20
Power
2.50 2.50 10
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump H15500N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70 Hz
22.50
65 Hz
20.00
17.50 60 Hz
15.00 55 Hz
Head 12.50 50 Hz
(m)
10.00
7.50
5.00
2.50
12.50
70 Hz
10.00
65 Hz
Power 7.50 60 Hz
(hp)
55 Hz
5.00
50 Hz
2.50
Return to Pumps
Return to Pumps
H21500N Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 17,500–24,000 B/D Shaft brake-power limit Standard 637 hp
Nominal housing diameter 5.63 in. High strength 1,019 hp
Shaft diameter 1.188 in. Housing burst-pressure limit Standard 3.000 psi
Shaft cross-sectional area 1.108 in.2 Buttress Not applicable Power Efficiency
Min. casing size 7 in. Welded 3,600 psi (hp) (%)
70 35 70
60 30 60
Head
50 25 50
Head 40 20 40
(ft) Efficiency
30 15 30
20 10 20
Power
10 5 10
Operating range
0 0 0
0 5,000 10,000 15,000 20,000 25,000 30,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump H21500N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
80 70 Hz
70 65 Hz
60 60 Hz
50 55 Hz
Head
(ft) 50 Hz
40
30
20
10
70 Hz
17.50
15.00 65 Hz
12.50 60 Hz
Power 10.00
(hp) 55 Hz
7.50 50 Hz
5.00
2.50
Return to Pumps
Return to Pumps
Pumps
17.50 17.50 70
7.50 7.50 30
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump H21500N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
22.50 70 Hz
65 Hz
20.00
17.50 60 Hz
15.00 55 Hz
Head 12.50 50 Hz
(m)
10.00
7.50
5.00
2.50
70 Hz
17.50
15.00 65 Hz
12.50
60 Hz
Power 10.00
(hp) 55 Hz
7.50 50 Hz
5.00
2.50
Return to Pumps
Return to Pumps
H28000N Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 28,000–36,000 B/D Shaft brake-power limit Standard 637 hp
Nominal housing diameter 5.63 in. High strength 1,019 hp
Shaft diameter 1.188 in. Housing burst-pressure limit Standard 3,000 psi
Shaft cross-sectional area 1.108 in.2 Buttress Not applicable Power Efficiency
Min. casing size 7.000 in. Welded 3,600 psi (hp) (%)
60 Efficiency 60 60
Head
50 50 50
40 40 40
Head
(ft)
30 30 30
Operating range
20 20 20
Power
10 10 10
0 0 0
0 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump H28000N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70
70 Hz
60 65 Hz
50 60 Hz
55 Hz
Head 40
(ft)
50 Hz
30
20
10
25.00 70 Hz
22.50
20.00 65 Hz
17.50
60 Hz
Power 15.00
(hp) 12.50 55 Hz
10.00 50 Hz
7.50
5.00
2.50
Return to Pumps
Return to Pumps
Pumps
15.00 30 60
Efficiency
10.00 20 40
Head
(m)
7.50 15 30
5.00 10 20
Power
2.50 5 10
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5,000
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump H28000N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
22.50
70 Hz
20.00
65 Hz
17.50
15.00 60 Hz
Head 55 Hz
12.50
(m)
50 Hz
10.00
7.50
5.00
2.50
25.00 70 Hz
22.50
20.00 65 Hz
17.50
60 Hz
Power 15.00
(hp) 12.50 55 Hz
10.00 50 Hz
7.50
5.00
2.50
Return to Pumps
Return to Pumps
J7000N Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 4,500–9,000 B/D Shaft brake-power limit Standard 637 hp
Nominal housing diameter 6.75 in. High strength 1,019 hp
Shaft diameter 1.188 in. Housing burst-pressure limit Standard Not applicable
Shaft cross-sectional area 1.188 in.2 Buttress 3,060 psi Power Efficiency
Min. casing size 8.625 in. Welded 3,060 psi (hp) (%)
175 35 70
150 Efficiency 30 60
Operating range
125 25 50
Head
Head 100 20 40
(ft)
75 15 30
50 10 20
25 Power 5 10
0 0 0
0 2,500 5,000 7,500 10,000 12,500
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump J7000N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70 Hz
125 65 Hz
60 Hz
100
55 Hz
Head 75 50 Hz
(ft)
50
25
12.50
70 Hz
10.00
65 Hz
Power 7.50 60 Hz
(hp)
55 Hz
5.00
2.50 50 Hz
Return to Pumps
Return to Pumps
Pumps
35 17.50 70
Efficiency
30 15.00 60
Operating range
25 12.50 50
Head
Head 20 10.00 40
(m)
15 7.50 30
10 5.00 20
5 Power 2.50 10
0 0 0
0 250 500 750 1,000 1,250 1,500 1,750
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump J7000N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
45
70 Hz
40
65 Hz
35
60 Hz
30
55 Hz
Head 25
(m)
50 Hz
20
15
10
12.50
70 Hz
10.00
65 Hz
Power 7.50
(hp) 60 Hz
55 Hz
5.00
2.50 50 Hz
0 250 500 750 1,000 1,250 1,500 1,750 2,000 2,250 2,500
Capacity (m /d)
3
Return to Pumps
Return to Pumps
J12000N Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 8,000–18,500 B/D Shaft brake-power limit Standard 637 hp
Nominal housing diameter 6.75 in. High strength 1,019 hp
Shaft diameter 1.188 in. Housing burst-pressure limit Standard Not applicable
Shaft cross-sectional area 1.108 in.2 Buttress 3,060 psi Power Efficiency
Min. casing size 8.625 in. Welded 3,060 psi (hp) (%)
175 35 70
Efficiency
150 30 60
Operating range
125 25 50
Head
Head 100 20 40
(ft)
75 15 30
50 10 20
Power
25 5 10
0 0 0
0 2,500 5,000 7,500 10,000 12,500 15,000 17,500 20,000 22,500 25,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
70 Hz
125
65 Hz
100 60 Hz
55 Hz
Head 75
(ft) 50 Hz
50
25
70 Hz
17.50
15.00 65 Hz
12.50 60 Hz
Power 10.00
(hp) 55 Hz
7.50 50 Hz
5.00
2.50
0 2,500 5,000 7,500 10,000 12,500 15,000 17,500 20,000 22,500 25,000 27,500
Capacity (B/D)
Return to Pumps
Return to Pumps
Pumps
35 17.50 70
Efficiency
30 15.00 60
Operating range
25 12.50 50
Head
Head 20 10.00 40
(m)
15 7.50 30
10 5.00 20
Power
5 2.50 10
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump J12000N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
45
70 Hz
40
65 Hz
35
60 Hz
30
Head 55 Hz
25
(m)
50 Hz
20
15
10
70 Hz
17.50
15.00 65 Hz
12.50
60 Hz
Power 10.00
(hp) 55 Hz
7.50 50 Hz
5.00
2.50
Return to Pumps
Return to Pumps
JN16000 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 12,800–19,500 B/D Shaft brake-power limit Standard 637 hp
Nominal housing diameter 6.75 in. High strength 1,019 hp
Shaft diameter 1.188 in. Housing burst-pressure limit Standard Not applicable
Shaft cross-sectional area 1.108 in.2 Buttress 3,060 psi Power Efficiency
Min. casing size 8.625 in. Welded 3,060 psi (hp) (%)
175 35 70
Efficiency
150 30 60
125 25 50
Operating range
Head 100 20 40
(ft) Head
75 15 30
50 Power 10 20
25 5 10
0 0 0
0 2,500 5,000 7,500 10,000 12,500 15,000 17,500 20,000 22,500 25,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump JN16000 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
125
70 Hz
100
65 Hz
60 Hz
Head 75
(ft) 55 Hz
50 Hz
50
25
17.50 70 Hz
15.00
65 Hz
12.50
60 Hz
Power 10.00
(hp) 55 Hz
7.50
50 Hz
5.00
2.50
Return to Pumps
Return to Pumps
Pumps
Head
17.50 17.50 70
15.00 15.00 60
12.50 12.50 50
Efficiency
Head 10.00 10.00 40
(m)
7.50 7.50 30
Power
5.00 5.00 20
2.50 2.50 10
Operating range
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump JN16000 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
35
70 Hz
30
65 Hz
25 60 Hz
Head 55 Hz
20
(m)
50 Hz
15
10
17.50 70 Hz
15.00
65 Hz
12.50
60 Hz
Power 10.00
(hp) 55 Hz
7.50
50 Hz
5.00
2.50
Return to Pumps
Return to Pumps
JN21000 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 16,000–25,000 B/D Shaft brake-power limit Standard 637 hp
Nominal housing diameter 6.75 in. High strength 1,019 hp
Shaft diameter 1.188 in. Housing burst-pressure limit Standard Not applicable
Shaft cross-sectional area 1.108 in.2 Buttress 3,060 psi Power Efficiency
Min. casing size 8.625 in. Welded 3,060 psi (hp) (%)
150 30 60
Efficiency
125 25 50
Operating range
100 20 40
Head Head
(ft)
75 15 30
50 Power 10 20
25 5 10
0 0 0
0 5,000 10,000 15,000 20,000 25,000 30,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump JN21000 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
125
100
70 Hz
Head 65 Hz
75
(ft)
60 Hz
55 Hz
50 50 Hz
25
17.50 70 Hz
15.00
65 Hz
12.50
60 Hz
Power 10.00
(hp) 55 Hz
7.50
50 Hz
5.00
2.50
Return to Pumps
Return to Pumps
Pumps
30 15.00 60
Efficiency
25 12.50 50
Operating range
20 10.00 40
Head
Head
(m)
15 7.50 30
Power
10 5.00 20
5 2.50 10
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump JN21000 Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
35
30
70 Hz
25
65 Hz
Head 20 60 Hz
(m)
55 Hz
15 50 Hz
10
17.50 70 Hz
15.00
65 Hz
12.50
60 Hz
Power 10.00
(hp) 55 Hz
7.50
50 Hz
5.00
2.50
Return to Pumps
Return to Pumps
L16000N Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 11,000–20,000 B/D Shaft brake-power limit Standard 637 hp
Nominal housing diameter 7.25 in. High strength 1,019 hp
Shaft diameter 1.188 in. Housing burst-pressure limit Standard Not applicable
Shaft cross-sectional area 1.108 in.2 Buttress 3.500 psi Power Efficiency
Min. casing size 9.625 in. Welded 3,500 psi (hp) (%)
175 70 70
Efficiency
150 60 60
Operating range
125 Head 50 50
Head 100 40 40
(ft)
75 30 30
50 20 20
Power
25 10 10
0 0 0
0 2,500 5,000 7,500 10,000 12,500 15,000 17,500 20,000 22,500 25,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump L16000N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
150 70 Hz
65 Hz
125
60 Hz
100
55 Hz
Head
(ft)
50 Hz
75
50
25
70 Hz
25
65 Hz
20
60 Hz
Power 15
(hp) 55 Hz
10
50 Hz
5
Return to Pumps
Return to Pumps
Pumps
35 35 70
Efficiency
30 30 60
Operating range
Head
25 25 50
Head 20 20 40
(m)
15 15 30
10 10 20
Power
5 5 10
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump L16000N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70 Hz
45
40 65 Hz
35
60 Hz
30
55 Hz
Head 25
(m) 50 Hz
20
15
10
70 Hz
25
20 65 Hz
60 Hz
Power 15
(hp) 55 Hz
10
50 Hz
5
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5,000
Capacity (m /d)
3
Return to Pumps
Return to Pumps
L43000N Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 36,000–54,000 B/D Shaft brake-power limit Standard 1,000 hp
Nominal housing diameter 7.25 in. High strength 1,500 hp
Shaft diameter 1.500 in. Housing burst-pressure limit Standard 2,000 psi
Shaft cross-sectional area 1.767 in.2 Buttress 3.500 psi Power Efficiency
Min. casing size 9.625 in. Welded 3,500 psi (hp) (%)
175 175 70
Efficiency
150 150 60
75 75 30
50 50 20
25 Power 25 10
0 0 0
0 10,000 20,000 30,000 40,000 50,000 60,000 70,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump L43000N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
125
70 Hz
100
65 Hz
60 Hz
Head 75
(ft) 55 Hz
50 Hz
50
25
70 Hz
50
65 Hz
40
60 Hz
Power 30
(hp) 55 Hz
20 50 Hz
10
Return to Pumps
Return to Pumps
Pumps
35 70 70
30 60 60
Efficiency
25 50 50
Operating range
Head
Head 20 40 40
(m)
15 30 30
10 20 20
Power
5 10 10
0 0 0
0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump L43000N Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
40
35
70 Hz
30
65 Hz
25 60 Hz
Head
(m) 55 Hz
20
50 Hz
15
10
50 70 Hz
40 65 Hz
60 Hz
Power 30
(hp)
55 Hz
20 50 Hz
10
Return to Pumps
Return to Pumps
M520 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 12,000–20,000 B/D Shaft brake-power limit Standard 637 hp
Nominal housing diameter 8.63 in. High strength 1,019 hp
Shaft diameter 1.188 in. Housing burst-pressure limit Standard 2,000 psi
Shaft cross-sectional area 1.108 in.2 Buttress 2,400 psi Power Efficiency
Min. casing size 10.75 in. Welded 2,400 psi (hp) (%)
175 70 70
Efficiency
150 Operating range 60 60
Head
125 50 50
Head 100 40 40
(ft)
75 30 30
50 20 20
Power
25 10 10
0 0 0
0 5,000 10,000 15,000 20,000 25,000 30,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump M520A Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
175 70 Hz
150 65 Hz
125 60 Hz
55 Hz
Head 100
(ft)
50 Hz
75
50
25
70 Hz
30
25 65 Hz
20 60 Hz
Power
(hp) 15 55 Hz
50 Hz
10
Return to Pumps
Return to Pumps
Pumps
35 35 70
Efficiency
30 Operating range 30 60
Head
25 25 50
Head 20 20 40
(m)
15 15 30
10 10 20
Power
5 5 10
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump M520A Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70 Hz
50
65 Hz
40
60 Hz
55 Hz
Head 30
(m)
50 Hz
20
10
70 Hz
30
25 65 Hz
20 60 Hz
Power
(hp) 15 55 Hz
50 Hz
10
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5,000 5,500
Capacity (m /d)
3
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 12,000–23,000 B/D Shaft brake-power limit Standard 637 hp
Nominal housing diameter 8.63 in. High strength 1,019 hp
Shaft diameter 1.188 in. Housing burst-pressure limit Standard 2,000 psi
Shaft cross-sectional area 1.108 in.2 Buttress 2,400 psi Power Efficiency
Min. casing size 10.75 in. Welded 2,400 psi (hp) (%)
175 70 70
Efficiency
150 60 60
Operating range
125 Head 50 50
Head 100 40 40
(ft)
75 30 30
50 20 20
Power
25 10 10
0 0 0
0 5,000 10,000 15,000 20,000 25,000 30,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump M520B Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
150
70 Hz
125 65 Hz
60 Hz
100
Head 55 Hz
(ft)
75 50 Hz
50
25
70 Hz
22.5
20.0 65 Hz
17.5
15.0 60 Hz
Power 12.5
(hp) 55 Hz
10.0
50 Hz
7.5
5.0
2.5
Return to Pumps
Return to Pumps
Pumps
35 35 70
Efficiency
30 30 60
Operating range
Head
25 25 50
Head 20 20 40
(m)
15 15 30
10 10 20
Power
5 5 10
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump M520B Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
50
45
70 Hz
40
65 Hz
35
60 Hz
30
Head
(m) 55 Hz
25
50 Hz
20
15
10
70 Hz
22.5
20.0 65 Hz
17.5
15.0 60 Hz
Power 12.5 55 Hz
(hp)
10.0
50 Hz
7.5
5.0
2.5
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 12,000–22,000 B/D Shaft brake-power limit Standard 637 hp
Nominal housing diameter 8.63 in. High strength 1,019 hp
Shaft diameter 1.188 in. Housing burst-pressure limit Standard 2,000 psi
Shaft cross-sectional area 1.108 in.2 Buttress 2,400 psi Power Efficiency
Min. casing size 10.75 in. Welded 2,400 psi (hp) (%)
175 35 70
Efficiency
150 30 60
Operating range
125 25 50
Head Head
100 20 40
(ft)
75 15 30
Power
50 10 20
25 5 10
0 0 0
0 2,500 5,000 7,500 10,000 12,500 15,000 17,500 20,000 22,500 25,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump M520C Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
125
70 Hz
100 65 Hz
60 Hz
Head 75
(ft) 55 Hz
50 Hz
50
25
20.0 70 Hz
17.5
65 Hz
15.0
12.5 60 Hz
Power
(hp) 10.0 55 Hz
7.5 50 Hz
5.0
2.5
Return to Pumps
Return to Pumps
Pumps
35 17.5 70
Efficiency
30 15.0 60
Head
Head 20 10.0 40
(m)
15 7.5 30
Power
10 5.0 20
5 2.5 10
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump M520C Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
40
35 70 Hz
30 65 Hz
60 Hz
25
Head
(m) 55 Hz
20
50 Hz
15
10
20.0 70 Hz
17.5
15.0 65 Hz
12.5 60 Hz
Power
(hp) 10.0 55 Hz
7.5 50 Hz
5.0
2.5
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5,000
Capacity (m /d) 3
Return to Pumps
Return to Pumps
M675 Pump
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 19,000–32,000 B/D Shaft brake-power limit Standard 637 hp
Nominal housing diameter 8.63 in. High strength 1,019 hp
Shaft diameter 1.188 in. Housing burst-pressure limit Standard 2,000 psi
Shaft cross-sectional area 1.108 in.2 Buttress 2,400 psi Power Efficiency
Min. casing size 10.75 in. Welded 2,400 psi (hp) (%)
175 175 70
Efficiency
125 125 50
75 75 30
50 50 20
25 Power 25 10
0 0 0
0 5,000 10,000 15,000 20,000 25,000 30,000 35,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump M675A Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
200
70 Hz
175
65 Hz
150
60 Hz
125
Head 55 Hz
(ft)
100
50 Hz
75
50
25
50 70 Hz
45
40 65 Hz
35
60 Hz
30
Power
(hp) 25 55 Hz
20 50 Hz
15
10
5
Return to Pumps
Return to Pumps
Pumps
35 Efficiency 70 70
25 50 50
Head 20 40 40
(m)
15 30 30
10 20 20
Power
5 10 10
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5,000
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump M675A Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
60
70 Hz
50
65 Hz
60 Hz
40
Head 55 Hz
(m)
30 50 Hz
20
10
50 70 Hz
45
40 65 Hz
35
60 Hz
30
Power
(hp) 25 55 Hz
20 50 Hz
15
10
5
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 19,000–29,000 B/D Shaft brake-power limit Standard 637 hp
Nominal housing diameter 8.63 in. High strength 1,019 hp
Shaft diameter 1.188 in. Housing burst-pressure limit Standard 2,000 psi
Shaft cross-sectional area 1.108 in.2 Buttress 2,400 psi Power Efficiency
Min. casing size 10.75 in. Welded 2,400 psi (hp) (%)
175 70 70
Efficiency
Head
125 50 50
Head 100 40 40
(ft)
75 30 30
50 Power 20 20
25 10 10
0 0 0
0 5,000 10,000 15,000 20,000 25,000 30,000 35,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump M675B Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70 Hz
150
65 Hz
125
60 Hz
100 55 Hz
Head
(ft) 50 Hz
75
50
25
70 Hz
40
35 65 Hz
30
60 Hz
25
Power
(hp) 20 55 Hz
15 50 Hz
10
Return to Pumps
Return to Pumps
Pumps
35 Efficiency 70 70
30 Operating range 60 60
Head
25 50 50
Head 20 40 40
(m)
15 30 30
10 20 20
Power
5 10 10
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5,000
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump M675B Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
50
70 Hz
45
40 65 Hz
35 60 Hz
30
Head 55 Hz
(m)
25
50 Hz
20
15
10
70 Hz
40
35 65 Hz
30
60 Hz
25
Power
(hp) 20 55 Hz
15 50 Hz
10
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 19,000–28,000 B/D Shaft brake-power limit Standard 637 hp
Nominal housing diameter 8.63 in. High strength 1,019 hp
Shaft diameter 1.188 in. Housing burst-pressure limit Standard 2,000 psi
Shaft cross-sectional area 1.108 in.2 Buttress 2,400 psi Power Efficiency
Min. casing size 10.75 in. Welded 2,400 psi (hp) (%)
175 70 70
Efficiency
150 60 60
Operating range
125 50 50
Head
Head 100 40 40
(ft)
75 30 30
50 20 20
Power
25 10 10
0 0 0
0 5,000 10,000 15,000 20,000 25,000 30,000 35,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump M675C Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70 Hz
125
65 Hz
100
60 Hz
55 Hz
Head 75
(ft)
50 Hz
50
25
35 70 Hz
30
65 Hz
25
60 Hz
Power 20
(hp) 55 Hz
15
50 Hz
10
Return to Pumps
Return to Pumps
Pumps
35 35 70
Efficiency
30 30 60
Operating range
25 25 50
Head
Head 20 20 40
(m)
15 15 30
10 Power 10 20
5 5 10
0 0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5,000
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump M675C Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
40
70 Hz
35
65 Hz
30
60 Hz
25
Head 55 Hz
(m)
20 50 Hz
15
10
35 70 Hz
30
65 Hz
25
60 Hz
Power 20
(hp) 55 Hz
15
50 Hz
10
Return to Pumps
Return to Pumps
N1050 Pump
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 24,000–47,500 B/D Shaft brake-power limit Standard 1,000 hp
Nominal housing diameter 9.50 in. High strength 1,600 hp
Shaft diameter 1.500 in. Housing burst-pressure limit Standard 2,300 psi
Shaft cross-sectional area 1.767 in.2 Buttress Not applicable Power Efficiency
Min. casing size 11.75 in. Welded 2,760 psi (hp) (%)
350 175 70
Efficiency
300 150 60
Head
Head 200 100 40
(ft)
150 75 30
100 Power 50 20
50 25 10
0 0 0
0 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000 45,000 50,000 55,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump N1050A Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
250 70 Hz
65 Hz
200
60 Hz
Head 150 55 Hz
(ft)
50 Hz
100
50
90 70 Hz
80
65 Hz
70
60 Hz
60
Power
(hp) 40 55 Hz
30 50 Hz
20
10
Return to Pumps
Return to Pumps
Pumps
70 175 70
Efficiency
60 150 60
Operating range
50 125 50
Head
Head 40 100 40
(m)
30 75 30
20 50 20
Power
10 25 10
0 0 0
0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump N1050A Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
80
70 Hz
70
65 Hz
60
60 Hz
50
Head 55 Hz
(m)
40 50 Hz
30
20
10
90 70 Hz
80
65 Hz
70
60 60 Hz
Power 50
(hp) 55 Hz
40
50 Hz
30
20
10
0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000 11,000
Capacity (m /d)
3
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 24,000–43,000 B/D Shaft brake-power limit Standard 1,000 hp
Nominal housing diameter 9.50 in. High strength 1,600 hp
Shaft diameter 1.500 in. Housing burst-pressure limit Standard 2,300 psi
Shaft cross-sectional area 1.767 in.2 Buttress Not applicable Power Efficiency
Min. casing size 11.75 in. Welded 2,760 psi (hp) (%)
Head
175 175 70
150 150 60
Efficiency
125 125 50
50 50 20
Power
25 25 10
0 0 0
0 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000 45,000 50,000 55,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump N1050B Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
225
70 Hz
200
65 Hz
175
60 Hz
150
Head 55 Hz
125
(ft)
50 Hz
100
75
50
25
70 70 Hz
60 65 Hz
40 60 Hz
Power
(hp) 55 Hz
30
50 Hz
20
10
Return to Pumps
Return to Pumps
Pumps
Head
70 70 70
40 60 60
30 50 50
Efficiency
Operating range
Head 20 40 40
(m)
15 30 30
Power
10 20 20
5 10 10
0 0 0
0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump N1050B Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
70
70 Hz
60
65 Hz
50
60 Hz
Head 40 55 Hz
(m)
50 Hz
30
20
10
70 70 Hz
60
65 Hz
50
60 Hz
Power 40
(hp) 55 Hz
30
50 Hz
20
10
0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000 11,000
Capacity (m /d)
3
Return to Pumps
Return to Pumps
N1400 Pump
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 35,000–64,000 B/D Shaft brake-power limit Standard 1,500 hp
Nominal housing diameter 10.00 in. High strength 2,400 hp
Shaft diameter 1.750 in. Housing burst-pressure limit Standard 2,300 psi
Shaft cross-sectional area 2.405 in.2 Buttress Not applicable Power Efficiency
Min. casing size 11.75 in. Welded Not applicable (hp) (%)
350 350 70
Efficiency
Head
250 250 50
150 150 30
100 100 20
Power
50 50 10
0 0 0
0 10,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump N1400A Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
350
70 Hz
300
65 Hz
250
60 Hz
Head 200 55 Hz
(ft)
50 Hz
150
100
50
175 70 Hz
150
65 Hz
125
60 Hz
Power 100
(hp) 55 Hz
75
50 50 Hz
25
Return to Pumps
Return to Pumps
Pumps
70 175 70
Efficiency
50 125 50
Head 40 100 40
(m)
30 75 30
20 50 20
Power
10 25 10
0 0 0
0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump N1400A Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
100
70 Hz
90
65 Hz
80
60 Hz
70
60 55 Hz
Head
(m) 50 Hz
50
40
30
20
10
175 70 Hz
150
65 Hz
125
60 Hz
Power 100
(hp) 55 Hz
75
50 50 Hz
25
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 35,000–60,000 B/D Shaft brake-power limit Standard 1,500 hp
Nominal housing diameter 10.00 in. High strength 2,400 hp
Shaft diameter 1.750 in. Housing burst-pressure limit Standard 2,300 psi
Shaft cross-sectional area 2.405 in.2 Buttress Not applicable Power Efficiency
Min. casing size 11.75 in. Welded Not applicable (hp) (%)
350 350 70
Efficiency
300 300 60
Operating range
250 Head 250 50
150 150 30
100 100 20
Power
50 50 10
0 0 0
0 10,000 20,000 30,000 40,000 50,000 60,000 70,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump N1400B Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
300
70 Hz
250 65 Hz
60 Hz
200
55 Hz
Head
(ft)
150 50 Hz
100
50
70 Hz
150
125 65 Hz
100 60 Hz
Power
(hp) 75 55 Hz
50 Hz
50
25
Return to Pumps
Return to Pumps
Pumps
70 175 70
Efficiency
60 150 60
Operating range
Head
50 125 50
Head 40 100 40
(m)
30 75 30
20 50 20
Power
10 25 10
0 0 0
0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump N1400B Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
90 70 Hz
80
65 Hz
70
60 Hz
60
55 Hz
Head 50
(m) 50 Hz
40
30
20
10
70 Hz
150
125 65 Hz
100 60 Hz
Power
(hp) 75 55 Hz
50
50 Hz
25
Return to Pumps
Return to Pumps
P2500A Pump
Return to Pumps
Return to Pumps
Pumps
Optimum operating range 53,486–96,001 B/D Shaft brake-power limit Standard 1,000 hp
Nominal housing diameter 11.25 in. High strength 1,600 hp
Shaft diameter 1.500 in. Housing burst-pressure limit Standard 1,400 psi
Shaft cross-sectional area 1.767 in.2 Buttress Not applicable Power Efficiency
Min. casing size 13.625 in. Welded Not applicable (hp) (%)
350 700 70
Head
300 600 60
250 500 50
Head Efficiency
200 400 40
(ft)
150 300 30
100 200 20
Power
50 100 10
Operating range
0 0 0
0 10,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000 110,000
Capacity (B/D)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump P2500A Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
400
350 70 Hz
300 65 Hz
60 Hz
250
Head
(ft) 55 Hz
200
50 Hz
150
100
50
250 70 Hz
225
200 65 Hz
175
60 Hz
150
Power
(hp) 125 55 Hz
100 50 Hz
75
50
25
Return to Pumps
Return to Pumps
Pumps
70 350 70
Efficiency
50 250 50
Head
(m) 40 200 40
30 150 30
20 100 20
Power
10 50 10
0 0 0
0 2,500 5,000 7,500 10,000 12,500 15,000
Capacity (m3⁄d)
This engineering performance curve represents nominal performance based on actual multistage testing and certification.
All pumps supplied by Schlumberger will be tested and certified to perform within the acceptable limits for Head, Power,
and Efficiency as defined in the API Recommended Practice (11S2) for Electric Submersible Pump Testing.
Return to Pumps
Return to Pumps
REDA* Pump P2500A Performance Curve
Curve computed for one stage in fluid of 1.00 sg.
125
70 Hz
100
65 Hz
Head 60 Hz
75
(m)
55 Hz
50 Hz
50
25
70 Hz
250
225
65 Hz
200
175
60 Hz
150
Power 55 Hz
125
(hp)
100 50 Hz
75
50
25
Return to Pumps
Pump Intakes
Economic limit
Time
Production Results
400 Series AGH* Advanced Gas Handling Device, D5-21 (500–2,100 B/D Capacity)
Description Length, Weight, Carbon Steel Redalloy*
ft [m] lbm [kg] Part Number Part Number
FL-CT-ES, high-strength shaft, 400/400† 6.3 [1.9] 135 [61.3] 1236686 1251941
FL-CT-ARZ, high-strength shaft, 400/400 6.3 [1.9] 135 [61.3] 1252279 1251925
CR-CT-ES, high-strength shaft, 400/400 6.3 [1.9] 135 [61.3] 1237890 1251743
CR-CT-ARZ, high-strength shaft, 400/400 6.3 [1.9] 135 [61.3] 1252444 1251453
† The first number denotes the head flange size; the second number denotes the base flange size.
400 Series AGH* Advanced Gas Handling Device, D20-60 (2,000–6,000 B/D Capacity)
Description Length, Weight, Carbon Steel Redalloy*
ft [m] lbm [kg] Part Number Part Number
C-CT-ES, high-strength shaft, 400/400† 6.3 [1.9] 135 [61.3] 1345859 tba‡
C-LT-ES, high-strength shaft, 400/400 6.3 [1.9] 135 [61.3] 2000095 tba
C-LT-ES-ZS, high-strength shaft, 400/400 6.3 [1.9] 135 [61.3] tba 2005146
† The first number denotes the head flange size; the second number denotes the base flange size.
‡ to be assigned
538 Series AGH* Advanced Gas Handling Device, S70-100 (7,000–10,000 B/D Capacity)
Description Length, Weight, Carbon Steel Redalloy*
ft [m] lbm [kg] Part Number Part Number
FL-CT-ES, high-strength shaft, 538/540† 6.3 [1.9] 284 [128.9] 1246008 1254614
FL-CT-ARZ, high-strength shaft, 538/540 6.3 [1.9] 284 [128.9] 1254580 1254598
ES CR-CT, high-strength shaft, 538/540 6.3 [1.9] 284 [128.9] 1254622 1254606
ARZ, CR-CT, high-strength shaft, 538/540 6.3 [1.9] 284 [128.9] 1254564 1254572
† The first number denotes the head flange size; the second number denotes the base flange size.
562 Series AGH* Advanced Gas Handling Device, H100-250, FL-CT (10,000–25,000 B/D Capacity)
Description Length, Weight, Carbon Steel Redalloy*
ft [m] lbm [kg] Part Number Part Number
C-LT, 562/540† 5.2 [1.6] 263 [119.4] 2010121 tba‡
C-LT-ES, modified shaft, 562/540 5.2 [1.6] 263 [119.4] 2010124 2010126
C-LT-ES, 562/540 5.2 [1.6] 263 [119.4] tba 2010111
C-LT-ARZ-SS, 562/540 5.2 [1.6] 263 [119.4] 2010100 2010110
C-LT-ARZ-SS, modified shaft, 562/540 5.2 [1.6] 263 [119.4] 2010128 2010127
C-LT-ES, 675/540 5.2 [1.6] 263 [119.4] 2010120 2010112
C-LT-ARZ-SS, 675/540 5.2 [1.6] 263 [119.4] 2010101 2010105
C-LT-ES, 725/540 5.2 [1.6] 263 [119.4] 2010119 2010113
C-LT-ARZ-SS, 725/540 5.2 [1.6] 263 [119.4] 2010102 2010106
C-LT-ES, 862/540 5.2 [1.6] 263 [119.4] 2010118 2010114
C-LT-ARZ-SS, 862/540 5.2 [1.6] 263 [119.4] 2010103 2010107
† The first number denotes the head flange size; the second number denotes the base flange size.
‡ to be assigned
562 Series Adapter Kits to Connect to 675, 725, and 862 Series Pumps
Description Carbon Steel Redalloy*
Part Number Part Number
675 Series, standard trim 2010249 tba†
675 Series, MONEL® trim 2010257 2010253
725 Series, standard trim 2010250 tba
725 Series, MONEL trim 2010258 2010254
862 Series, standard trim 2010251 tba
862 Series, MONEL trim 2010259 2010255
862 Series, standard trim, high-strength shaft 2010252 tba
862 Series, MONEL trim, high-strength shaft 2010260 2010256
† to be assigned
Back to Protectors
Modular Protector Nomenclature
Nomenclature Definitions
Type Description
66L Two-chambered labyrinth design
SB Positive seal protector using a single elastomeric bag
DB Positive seal protector with two elastomeric bags connected in parallel
PF Prefilled protector
HL High-load thrust bearing
HSS Indicates the use of high-strength shaft
HTM Indicates the use of high-temperature materials in the protector
Back to Protectors
Elastomer Application Guidelines
Performance Ratings
Elastomer Neoprene/Nitrile Carboxynitrile HSN Viton® Aflas®
Temperature limit, °F [°C] 250 [121] 275 [135] 300 [149] 351 [177] 399 [204]
Water/oil 1 1 1 2 1
Hydrogen sulfide 1 3 1 4 1
Amines 3 3 3 4 1
Polar chemicals 4 4 1–2 3 3
Carbon dioxide 2 2 2 4 2
Definition of ratings: 1 = Excellent—long-term resistance (low swell, high retention of physical properties); 2 = Good—long-term resistance (moderate swell, good retention of physical properties);
3 = Fair—depends on exposure time and temperature (good short-term resistance); 4 = Poor—no resistance, even in the short term
Note: Temperature limit indicates maximum operating temperature for the elastomers. An elastomeric component will operate at a higher temperature than the ambient wellbore temperature, depending on its location
in the equipment. Consult your Schlumberger representative for specific application assistance.
Back to Protectors
Advanced Motor Protector
Back to Protectors
The advanced protector system can Specifications
operate in high-temperature and high-
H2S environments. It improves ESP OD, in. [mm] 5.130 [130.30]
performance in such environments, Max. bottomhole temperature, °F [°C] 425 [218]
significantly increasing operating Length Dictated by system configuration
reliability. Metallurgy Carbon steel or Redalloy* high-nickel alloy
The high-temperature advanced Chambers Metal bellows, bag, or labyrinth
protector has a proven success record Shaft diameter, in. [mm] 1.187 [30.15]
in many steamflood injection applica- Deviation angle, ° 0–90
tions at its maximum operating limits.
Back to Protectors
Modular Protector Configurations
Back to Protectors
540 Series Modular (Bolts to 540 and 562 Series Motors)
Description Length, Weight, Carbon Steel Redalloy*
ft [m] lbm [kg] Part Number Part Number
LSL 6.5 [2.0] 276 [125.3] 1068394 1069871
LSL-HL 6.5 [2.0] 276 [125.3] 1067693 1069863
LSB 6.5 [2.0] 282 [128.0] 1068402 1069889
LSB-HL 6.5 [2.0] 282 [128.0] 1133289 K06840A
BSL 6.5 [2.0] 285 [129.4] 1075530 1136068
BSB 6.5 [2.0] 292 [132.6] 1134873 tba†
BSB-HL 6.5 [2.0] 292 [132.6] 1263631 tba
LSLSL 8.9 [2.7] 370 [168.0] 1076371 1074533
LSBPB 8.9 [2.7] 382 [173.4] 1045400 1069913
LSLSL-HL 8.9 [2.7] 370 [168.0] 1067685 1069855
LSBPB-HL 8.9 [2.7] 382 [173.4] 1067701 1069848
LSLSB-HL 8.9 [2.7] 370 [168.0] 1108547 1133941
LSLSL-HL-HSS 8.9 [2.7] 370 [168.0] 2006413 1309244
BSBSL 8.9 [2.7] 382 [173.4] 1075548 tba
BPBSL-HL 8.9 [2.7] 382 [173.4] 1108505 1180330
† to be assigned
Back to Protectors
Motors
Return to Motors
REDA ESP Motors
All REDA* ESP motors are designed REDA ESP Motor Capacity Ranges
for reliable operation in the extreme
environments common to oilwell Power Rating, hp
applications. Min. Casing OD, in. [mm] Motor Series Frequency, 60 Hz Frequency, 50 Hz
The motors are two-pole, three- 4.500 [114.3] 375 7.5–233 6.3–198
phase squirrel-cage induction type, 5.500 [139.7] 456 12.0–432 10.0–360
and handwound. They are filled with 7.000 [177.8] 540 20.0–750 16.5–562
a highly refined mineral oil to provide 7.000 [177.8] 562 30.0–1,170 25.0–975
dielectric strength, lubrication for 8.625 [219.1] 738 250.0–1,500 208.0–1,250
bearings, and thermal conductivity.
The motor thrust bearing carries the
load of the rotors. Heat generated by
the motor is transferred to the well
fluid as it flows by the motor housing.
Corrosion protection is provided
with flame spray coatings or ferritic
steel construction. High-temperature,
high-load thrust bearings and high-
strength shafts are available. To
reduce power costs, all motors feature
proprietary winding configurations to
optimize electrical performance and
improve efficiency.
The Dominator* motor series 456,
562, and 738 feature a comprehensive
new rotor and stator design that cost
effectively delivers the best perform-
ance available for wells with 51⁄2-in.
[139.7-mm] and larger casing.
Return to Motors
Dominator Motors
Return to Motors
Bolt-On Motor Bases
Return to Motors
375 Series Motors
Return to Motors
375 Series Motors—SX Type
Frequency, 60 Hz Frequency, 50 Hz
Power Voltage, V Power Voltage, V Current, A Type Length, Weight, Carbon Steel Redalloy* Alloy
Rating, hp Rating, hp ft [m] lbm [kg] Part Number Part Number
14 475 12 396 14.0 UT 6.3 [1.9] 208 [94] 1210095 tba†
19 465 16 387 20.5 UT 8.2 [2.5] 270 [123] 1210103 tba
UT 11.1 [3.4] 361 [164] 1210111 tba
28 475 23 396 28.0
CT 11.1 [3.4] 361 [164] 1210210 tba
UT 13.8 [4.2] 456 [207] 1210129 tba
360 300 51.0
CT 13.9 [4.2] 456 [207] 1210228 tba
36 30
UT 13.8 [4.2] 456 [207] 1210137 tba
387 322 38.0
CT 13.9 [4.2] 456 [207] 1210236 tba
UT 15.7 [4.8] 514 [233] 1210145 tba
415 346 51.5
CT 15.8 [4.8] 514 [233] 1210244 tba
41 34
UT 15.7 [4.8] 514 [233] 1210152 tba
440 367 39.0
CT 15.8 [4.8] 514 [233] tba tba
UT 17.6 [5.4] 660 [300] 1210160 tba
475 396 51.0
CT 17.7 [5.4] 660 [300] 1210251 tba
UT 17.6 [5.4] 660 [300] 1210178 tba
640 533 37.0
CT 17.7 [5.4] 660 [300] 1210269 tba
47 39
UT 17.6 [5.4] 660 [300] 1210186 tba
805 671 30.0
CT 17.7 [5.4] 660 [300] 1210277 tba
UT 17.6 [5.4] 660 [300] 1210194 tba
975 812 25.0
CT 17.7 [5.4] 660 [300] 2003452 tba
† to be assigned
Return to Motors
456 Dominator Motors
Return to Motors
456 Dominator* Motors—RX Type (continued)
Frequency, 60 Hz Frequency, 50 Hz
Power Voltage, V Power Voltage, V Current, A Type Length, Weight, Carbon Steel Redalloy* Alloy
Rating, hp Rating, hp ft [m] lbm [kg] Part Number Part Number
S 13.8 [4.2] 632 [286.9] 2004090 2004276
968 807 55.5
UT 13.8 [4.2] 632 [286.9] 2004571 2004668
S 13.8 [4.2] 632 [286.9] 2004091 2004279
1,252 1,043 43.0
UT 13.8 [4.2] 632 [286.9] 2004574 2004671
84 70
S 13.8 [4.2] 632 [286.9] 2000864 2004277
1,394 1,162 38.5
UT 13.8 [4.2] 632 [286.9] 2004572 2004669
S 13.8 [4.2] 632 [286.9] 2000865 2004278
2,102 1,752 25.5
UT 13.8 [4.2] 632 [286.9] 2004573 2004670
S 15.4 [4.7] 705 [320.1] 2004092 2004280
945 788 65.0
UT 15.4 [4.7] 705 [320.1] 2004575 2004672
S 15.4 [4.7] 705 [320.1] 2000866 2004281
96 1,430 80 1,192 43.0
UT 15.4 [4.7] 705 [320.1] 2004576 2004673
S 15.4 [4.7] 705 [320.1] 2000867 2004282
2,402 2,002 25.5
UT 15.4 [4.7] 705 [320.1] 2004577 2004674
S 17.0 [5.2] 779 [353.7] 2000868 2004283
881 734 78.5 UT 17.0 [5.2] 779 [353.7] 2000822 2004675
LT 17.0 [5.2] 779 [353.7] 2000829 2004793
S 17.0 [5.2] 779 [353.7] 2000869 2004284
108 90
1,427 1,189 48.5 UT 17.0 [5.2] 779 [353.7] 2004578 2004676
LT 17.0 [5.2] 779 [353.7] 2000830 2004794
S 17.0 [5.2] 779 [353.7] 2000870 2004285
2,520 2,100 27.5
UT 17.0 [5.2] 779 [353.7] 2004579 2004677
S 18.6 [5.7] 852 [386.8] 2000871 2004286
1,181 984 65.0 UT 18.6 [5.7] 852 [386.8] 2000823 2004678
LT 18.6 [5.7] 852 [386.8] 2000831 2004795
S 18.6 [5.7] 852 [386.8] 2004093 2004287
1,586 1,322 48.5 UT 18.6 [5.7] 852 [386.8] 2000824 2004679
120 100 LT 18.6 [5.7] 852 [386.8] 2000832 2004796
S 18.6 [5.7] 852 [386.8] 2004094 2004289
2,194 1,828 35.0 UT 18.6 [5.7] 852 [386.8] 2004581 2004681
LT 18.6 [5.7] 852 [386.8] 2004767 2004797
S 18.6 [5.7] 852 [386.8] 2000872 2004288
2,598 2,165 29.5
UT 18.6 [5.7] 852 [386.8] 2004580 2004680
S 20.2 [6.2] 925 [420.0] 2004095 2004290
1,076 897 78.5 UT 20.2 [6.2] 925 [420.0] 2003181 2004682
LT 20.2 [6.2] 925 [420.0] 2003524 2004798
S 20.2 [6.2] 925 [420.0] 2004096 2004291
1,299 1,083 65.0 UT 20.2 [6.2] 925 [420.0] 2004582 2004683
132 110 LT 20.2 [6.2] 925 [420.0] 2004768 2004799
S 20.2 [6.2] 925 [420.0] 2004097 2004293
2,413 2,011 35.0
UT 20.2 [6.2] 925 [420.0] 2004584 2004685
S 20.2 [6.2] 925 [420.0] 2000873 2004292
2,635 2,196 32.0
UT 20.2 [6.2] 925 [420.0] 2004583 2004684
Return to Motors
456 Dominator* Motors—RX Type (continued)
Frequency, 60 Hz Frequency, 50 Hz
Power Voltage, V Power Voltage, V Current, A Type Length, Weight, Carbon Steel Redalloy* Alloy
Rating, hp Rating, hp ft [m] lbm [kg] Part Number Part Number
S 21.8 [6.6] 998 [453.1] 2004098 2004294
931 776 99.0 UT 21.8 [6.6] 998 [453.1] 2004585 2004686
LT 21.8 [6.6] 998 [453.1] 2004769 2004800
S 21.8 [6.6] 998 [453.1] 2004099 2004295
1,174 978 78.5 UT 21.8 [6.6] 998 [453.1] 2000825 2004687
LT 21.8 [6.6] 998 [453.1] 2000833 2004801
144 120 S 21.8 [6.6] 998 [453.1] 2004100 2004297
2,145 1,788 43.0 UT 21.8 [6.6] 998 [453.1] 2004587 2004689
LT 21.8 [6.6] 998 [453.1] 2004770 2004802
S 21.8 [6.6] 998 [453.1] 2004101 2004298
2,389 1,991 38.5
UT 21.8 [6.6] 998 [453.1] 2004588 2004690
S 21.8 [6.6] 998 [453.1] 2000874 2004296
2,631 2,193 35.0
UT 21.8 [6.6] 998 [453.1] 2004586 2004688
S 23.4 [7.1] 1,072 [486.7] 2000875 2004299
1,272 1,060 78.5 UT 23.4 [7.1] 1,072 [486.7] 2004589 2004691
LT 23.4 [7.1] 1,072 [486.7] 2004771 2004803
S 23.4 [7.1] 1,072 [486.7] 2004103 2004300
156 130
1,535 1,279 65.0 UT 23.4 [7.1] 1,072 [486.7] 2000826 2004692
LT 23.4 [7.1] 1,072 [486.7] 2000834 2004804
S 23.4 [7.1] 1,072 [486.7] 2000876 2004301
2,588 2,157 38.5
UT 23.4 [7.1] 1,072 [486.7] 2004590 2004693
S 25.0 [7.6] 1,145 [519.8] 2004104 2004302
1,086 905 99.0 UT 25.0 [7.6] 1,145 [519.8] 2000827 2004694
168 140 LT 25.0 [7.6] 1,145 [519.8] 2000835 2004805
S 25.0 [7.6] 1,145 [519.8] 2004105 2004303
2,503 2,086 43.0
UT 25.0 [7.6] 1,145 [519.8] 2004591 2004695
S 26.6 [8.1] 1,218 [553.0] 2004106 2004304
180 2,682 150 2,235 43.0
UT 26.6 [8.1] 1,218 [553.0] 2004592 2004696
S 28.2 [8.6] 1,292 [586.6] 2003684 2004305
1,890 1,575 65.0 UT 28.2 [8.6] 1,292 [586.6] 2003685 2004697
192 160 LT 28.2 [8.6] 1,292 [586.6] 2003686 2004806
S 28.2 [8.6] 1,292 [586.6] 2003687 2004306
2,537 2,114 48.5
UT 28.2 [8.6] 1,292 [586.6] 2004593 2004698
S 29.9 [9.1] 1,369 [621.5] 2004108 2004308
2,008 1,673 65.0
UT 29.9 [9.1] 1,369 [621.5] 2004595 2004700
204 170 S 29.9 [9.1] 1,369 [621.5] 2004107 2004307
2,695 2,246 48.5 UT 29.9 [9.1] 1,369 [621.5] 2004594 2004699
LT 29.9 [9.1] 1,369 [621.5] 2004772 2004807
Return to Motors
456 Dominator* Motors—RX Type (continued)
Frequency, 60 Hz Frequency, 50 Hz
Power Voltage, V Power Voltage, V Current, A Type Length, Weight, Carbon Steel Redalloy* Alloy
Rating, hp Rating, hp ft [m] lbm [kg] Part Number Part Number
S 31.5 [9.6] 1,443 [655.1] 2000877 2004309
1,397 1,164 99.0 UT 31.5 [9.6] 1,443 [655.1] 2000828 2004701
LT 31.5 [9.6] 1,443 [655.1] 2000836 2004808
S 31.5 [9.6] 1,443 [655.1] 2003691 2004312
1,762 1,468 78.5 UT 31.5 [9.6] 1,443 [655.1] 2003692 2004704
216 180 LT 31.5 [9.6] 1,443 [655.1] 2003693 2004810
S 31.5 [9.6] 1,443 [655.1] 2003688 2004311
2,125 1,771 65.0 UT 31.5 [9.6] 1,443 [655.1] 2003689 2004703
LT 31.5 [9.6] 1,443 [655.1] 2003690 2004809
S 31.5 [9.6] 1,443 [655.1] 2004109 2004310
2,490 2,075 55.5
UT 31.5 [9.6] 1,443 [655.1] 2004596 2004702
Return to Motors
456 Dominator Motors
Return to Motors
456 Dominator* Motors—RK Type (continued)
Frequency, 60 Hz Frequency, 50 Hz
Power Voltage, V Power Voltage, V Current, A Type Length, Weight, Carbon Steel Redalloy* Alloy
Rating, hp Rating, hp ft [m] lbm [kg] Part Number Part Number
1,086 905 99.0 UT 25.0 [7.6] 1,145 [519.8] 100037553 100041727
168 140
2,503 2,086 43.0 UT 25.0 [7.6] 1,145 [519.8] 100037593 100042209
180 2,682 150 2,235 43.0 UT 26.6 [8.1] 1,218 [553.0] 100037607 100042210
1,890 1,575 65.0 UT 28.2 [8.6] 1,292 [586.6] 100037611 100042213
192 160
2,537 2,114 48.5 UT 28.2 [8.6] 1,292 [586.6] 100037616 100042215
2,008 1,673 65.0 UT 29.9 [9.1] 1,369 [621.5] 100037628 100042225
204 170
2,695 2,246 48.5 UT 29.9 [9.1] 1,369 [621.5] 100037626 100042217
1,397 1,164 99.0 UT 31.5 [9.6] 1,443 [655.1] 100037630 100042228
1,762 1,468 78.5 UT 31.5 [9.6] 1,443 [655.1] 100037642 100042232
216 180
2,125 1,771 65.0 UT 31.5 [9.6] 1,443 [655.1] 100037637 100042230
2,490 2,075 55.5 UT 31.5 [9.6] 1,443 [655.1] 100037633 100042229
Return to Motors
456 Dominator Motors
Return to Motors
456 Dominator* Motors—RX Type with Integral Phoenix* Sensor Adapter (continued)
Frequency, 60 Hz Frequency, 50 Hz
Power Voltage, V Power Voltage, V Current, A Type Length, Weight, Carbon Steel Redalloy* Alloy
Rating, hp Rating, hp ft [m] lbm [kg] Part Number Part Number
S 22.1 [6.7] 1,023 [464.4] 100010826 100012720
931 776 99.2
LT 22.1 [6.7] 1,018 [462.2] 100018423 100018831
S 22.1 [6.7] 1,023 [464.4] 100010828 100012728
1,174 978 78.7
LT 22.1 [6.7] 1,018 [462.2] 100018428 100018853
144 120
S 22.1 [6.7] 1,023 [464.4] 100010836 100012730
2,145 1,788 43.1
LT 22.1 [6.7] 1,018 [462.2] 100018433 100018857
2,389 1,991 38.7 S 22.1 [6.7] 1,023 [464.4] 100010838 100012733
2,631 2,193 35.1 S 22.1 [6.7] 1,023 [464.4] 100010834 100012729
S 23.7 [7.2] 1,101 [499.9] 100010843 100012736
1,272 1,060 78.7
LT 23.6 [7.2] 1,092 [495.8] 2013326 100018866
156 130 S 23.7 [7.2] 1,101 [499.9} 100010851 100012739
1,535 1,279 65.2
LT 23.6 [7.2] 1,092 [495.8] 100018445 100018869
2,588 2,157 38.7 S 23.7 [7.2] 1,101 [499.9] 100010883 100012742
S 25.3 [7.2] 1,174 [533.0] 100010914 100012743
1,086 905 99.3
168 140 LT 25.2 [7.7] 1,165 [528.9] 2013327 100018877
2,503 2,086 43.1 S 25.3 [7.7] 1,174 [533.0] 2013334 100012745
180 2,682 150 2,235 43.1 S 26.9 [8.2] 1,247 [566.1] 2013335 100012751
S 28.5 [8.7] 1,321 [599.7] 100010917 100012755
1,890 1,575 65.2
192 160 LT 28.4 [8.7] 1,316 [597.5] 2013328 100018879
2,537 2,114 48.6 S 28.5 [8.7] 1,321 [599.7] 2013336 100012774
S 30.1 [9.2] 1,394 [632.9] 100010973 100012777
2,008 1,673 65.2
204 170 LT 30.1 [9.2] 1,390 [631.1] 100018447 100018880
2,695 2,246 48.6 S 30.1 [9.2] 1,394 [632.9] 100010966 100012776
S 31.6 [9.6] 1,463 [664.2] 100010975 100012779
1,397 1,164 99.2
LT 31.6 [9.6] 1,468 [666.5] 100018450 100018881
S 31.7 [9.7] 1,468 [666.5] 100010988 100012784
1,762 1,468 78.7
216 180 LT 31.6 [9.6] 1,463 [664.2] 2013329 100018887
S 31.7 [9.7] 1,468 [666.5] 2013337 100018884
2,125 1,771 65.2
LT 31.6 [9.6] 1,463 [664.2] 100018451 100012783
2,490 2,075 55.7 S 31.7 [9.7] 1,468 [666.5] 100010982 100012781
Return to Motors
456 Dominator Motors
Return to Motors
456 Dominator* Motors—RK Type with Integral Phoenix* Sensor Adapter (continued)
Frequency, 60 Hz Frequency, 50 Hz
Power Voltage, V Power Voltage, V Current, A Type Length, Weight, Carbon Steel Redalloy* Alloy
Rating, hp Rating, hp ft [m] lbm [kg] Part Number Part Number
S 22.1 [6.7] 1,023 [464.4] 100029538 100032858
931 776 99.2
LT 22.1 [6.7] 1,018 [462.2] 100019760 100022162
S 22.1 [6.7] 1,023 [464.4] 100029540 100032859
1,174 978 78.7
LT 22.1 [6.7] 1,018 [462.2] 100019762 100022164
144 120
S 22.1 [6.7] 1,023 [464.4] 100031565 100032864
2,145 1,788 43.1
LT 22.1 [6.7] 1,018 [462.2] 100019764 100022167
2,389 1,991 38.7 S 22.1 [6.7] 1,023 [464.4] 100031569 100032872
2,631 2,193 35.1 S 22.1 [6.7] 1,023 [464.4] 100029542 100032862
S 23.7 [7.2] 1,101 [499.9] 100031573 100032874
1,272 1,060 78.7
LT 23.6 [7.2] 1,092 [495.8] 100019765 100022169
156 130 S 23.7 [7.2] 1,101 [499.9] 100031583 100032878
1,535 1,279 65.2
LT 23.6 [7.2] 1,092 [495.8] 100019767 100022170
2,588 2,157 38.7 S 23.7 [7.2] 1,101 [499.9] 100031589 100032879
S 25.3 [7.7] 1,174 [533.0] 100031597 100032881
1,086 905 99.3
168 140 LT 25.2 [7.7] 1,165 [528.9] 100019768 100022171
2,503 2,086 43.1 S 25.3 [7.7] 1,174 [533.0] 100031600 100032884
180 2,682 150 2,235 43.1 S 26.9 [8.2] 1,247 [566.1] 100031604 100032886
S 28.5 [8.7] 1,321 [599.7] 100031609 100032889
1,890 1,575 65.2
192 160 LT 28.4 [8.7] 1,316 [597.5] 100019769 100022172
2,537 2,114 48.6 S 28.5 [8.7] 1,321 [599.7] 100031614 100032891
S 30.1 [9.2] 1,394 [632.9] 100031618 100032894
2,008 1,673 65.2
204 170 LT 30.1 [9.2] 1,390 [632.9] 100019771 100022174
2,695 2,246 48.6 S 30.1 [9.2] 1,394 [632.9] 100031617 100032893
S 31.7 [9.7] 1,468 [666.5] 100031657 100032895
1,397 1,164 99.2
LT 31.6 [9.6] 1,463 [664.2] 100019772 100022176
S 31.7 [9.7] 1,468 [666.5] 100031680 100032902
1,762 1,468 78.7
216 180 LT 31.6 [9.6] 1463 [664.2] 100019775 100022179
S 31.7 [9.7] 1,468 [666.5] 100031674 100032900
2,125 1,771 65.2
LT 31.6 [9.6] 1,463 [664.2] 100019774 100022178
2,490 2,075 55.7 S 31.7 [9.7] 1,468 [666.5] 100031662 100032898
Return to Motors
540 Series Motors
Return to Motors
540 Series Motors—DK Type (continued)
Frequency, 60 Hz Frequency, 50 Hz
Power Voltage, V Power Voltage, V Current, A Type Length, Weight, Carbon Steel Redalloy* Alloy
Rating, hp Rating, hp ft [m] lbm [kg] Part Number Part Number
S 13.0 [4.0] 2011949 tba†
844 703 74.5 808 [366.8]
UT 13.1 [4.0] tba tba
S 13.0 [4.0] tba tba
1,018 848 61.8 808 [366.8]
UT 13.1 [4.0] 2011745 tba
100 83
S 13.0 [4.0] 2011950 tba
1,368 1,140 46.0 808 [366.8]
UT 13.1 [4.0] tba 2011713
S 13.0 [4.0] 2011710 2011723
2,590 2,157 24.3 808 [366.8]
UT 13.1 [4.0] 2011746 tba
S 15.7 [4.8] 2011951 tba
1,491 1,242 52.7 976 [443.1]
UT 15.8 [4.8] 2011934 tba
S 15.7 [4.8] tba tba
125 1,710 104 1,424 46.0 976 [443.1]
UT 15.8 [4.8] tba 2011921
S 15.7 [4.8] 2011711 tba
2,583 2,152 30.4 976 [443.1]
UT 15.8 [4.8] 2011747 2011923
S 19.4 [5.9] tba tba
1,004 836 93.9 UT 18.7 [5.7] 1,169 [530.7] 2011748 tba
CT 18.9 [5.8] tba tba
S 19.4 [5.9] tba tba
150 1,266 125 1,055 74.5 UT 18.7 [5.7] 1,169 [530.7] 2011749 2011714
CT 18.9 [5.8] 2011831 2011827
S 19.4 [5.9] 2012047 1060409
2,575 2,145 36.6 UT 18.7 [5.7] 1,194 [542.1] 2011751 2011916
CT 18.9 [5.8] 2011887 tba
S 20.0 [6.1] tba tba
163 2,790 135 2,324 36.6 1,243 [564.3]
UT 20.0 [6.1] tba 2011890
S 22.2 [6.8] tba tba
1,171 975 94.0 UT 21.2 [6.5] 1,336 [606.5] tba tba
CT 21.5 [6.6] 2011888 tba
S 22.2 [6.8] tba tba
175 146
1,477 1,230 74.5 UT 21.2 [6.5] 1,336 [606.5] 2011752 2011715
CT 21.5 [6.6] 2011832 2011823
S 22.2 [6.8] 2012048 2012045
2,393 1,993 46.0 1,380 [626.5]
UT 21.2 [6.5] 2011935 2011716
S 24.9 [7.6] tba tba
1,339 1,115 93.9 UT 24.1 [7.4] 1,492 [677.4] 2011753 2011718
200 167 CT 24.3 [7.4] 2011835 2011821
S 24.9 [7.6] 2012049 tba
2,386 1,998 52.7 1,498 [680.1]
UT 24.1 [7.4] 2011936 2011768
† to be assigned
Return to Motors
540 Series Motors—DK Type (continued)
Frequency, 60 Hz Frequency, 50 Hz
Power Voltage, V Power Voltage, V Current, A Type Length, Weight, Carbon Steel Redalloy* Alloy
Rating, hp Rating, hp ft [m] lbm [kg] Part Number Part Number
S 27.6 [8.4] tba† tba
1,113 927 127.1 UT 26.7 [8.1] 1,672 [759.1] 2011937 tba
CT 27.1 [8.3] tba tba
S 27.6 [8.4] tba tba
1,506 1,254 93.9 UT 26.7 [8.1] 1,672 [759.1] 2011754 2011719
225 188
CT 27.0 [8.2] 2011837 2011820
S 27.6 [8.4] 2011981 tba
2,292 1,909 61.7 1,654 [750.9]
UT 26.7 [8.1] 2011926 tba
S 27.6 [8.4] 2012050 2012044
2,685 2,237 52.7 1,716 [779.1]
UT 26.7 [8.1] 2011755 2011720
S 30.4 [8.3] tba tba
1,237 1,030 127.1 UT 29.5 [9.0] 1,890 [858.1] 2011756 2011721
CT 29.7 [9.1] 2011889 2011773
S 30.4 [9.3] tba tba
250 1,673 208 1,394 94.0 UT 29.5 [9.0] 1,846 [838.1] 2011925 tba
CT 29.7 [9.1] 2011883 tba
S 30.4 [9.3] 2012055 2012046
2,547 2,122 61.7 UT 29.5 [9.0] 1,840 [835.4] 2011757 2011728
CT 29.7 [9.1] 2011884 tba
† to be assigned
Return to Motors
540 Series Motors
Return to Motors
540 Series Motors—DX Type (continued)
Frequency, 60 Hz Frequency, 50 Hz
Power Voltage, V Power Voltage, V Current, A Type Length, Weight, Carbon Steel Redalloy* Alloy
Rating, hp Rating, hp ft [m] lbm [kg] Part Number Part Number
S 13.1 [4.0] tba† tba
844 703 74.5 808 [366.8]
UT 13.1 [4.0] tba tba
S 13.1 [4.0] tba tba
1,018 848 61.8 808 [366.8]
UT 13.1 [4.0] 100033717 tba
100 83
S 13.1 [4.0] tba tba
1,368 1,140 46.0 808 [366.8]
UT 13.1 [4.0] tba tba
S 13.1 [4.0] tba tba
2,590 2,157 24.3 808 [366.8]
UT 13.1 [4.0] tba tba
S 15.7 [4.8] tba tba
1,491 1,242 52.7 976 [443.1]
UT 15.8 [4.8] tba tba
S 15.7 [4.8] tba tba
125 1,710 104 1,424 46.0 976 [443.1]
UT 15.8 [4.8] tba tba
S 15.7 [4.8] tba tba
2,583 2,152 30.4 976 [443.1]
UT 15.8 [4.8] tba tba
S 19.4 [5.9] tba tba
1,004 836 93.9 UT 18.7 [5.7] 1,169 [530.7] 100033716 tba
CT 18.9 [5.8] tba tba
S 19.4 [5.9] tba tba
150 1,266 125 1,055 74.5 UT 18.7 [5.7] 1,169 [530.7] tba tba
CT 18.9 [5.8] tba tba
S 19.4 [5.9] 2012053 tba
2,575 2,145 36.6 UT 18.7 [5.7] 1,194 [542.1] 2011736 tba
CT 18.9 [5.8] tba tba
S 20.0 [6.1] tba tba
163 2,790 135 2,324 36.6 1,243 [564.3]
UT 20.0 [6.1] tba tba
S 22.2 [6.8] tba tba
1,171 975 94.0 UT 21.2 [6.5] 1,336 [606.5] tba tba
CT 21.5 [6.6] tba tba
S 22.2 [6.8] tba tba
175 146
1,477 1,230 74.5 UT 21.2 [6.5] 1,336 [606.5] tba 2011729
CT 21.5 [6.6] tba 2011767
S 22.2 [6.8] 2012054 tba
2,393 1,993 46.0 1,380 [626.5]
UT 21.2 [6.5] tba tba
S 24.9 [7.6] tba tba
1,339 1,115 93.9 UT 24.1 [7.4] 1,492 [677.4] tba 100033721
200 167 CT 24.3 [7.4] tba 100033722
S 24.9 [7.6] tba tba
2,386 1,998 52.7 1,498 [680.1]
UT 24.1 [7.4] tba tba
† to be assigned
Return to Motors
540 Series Motors—DX Type (continued)
Frequency, 60 Hz Frequency, 50 Hz
Power Voltage, V Power Voltage, V Current, A Type Length, Weight, Carbon Steel Redalloy* Alloy
Rating, hp Rating, hp ft [m] lbm [kg] Part Number Part Number
S 27.6 [8.4] tba† tba
1,113 927 127.1 UT 26.7 [8.1] 1,672 [759.1] 2011737 tba
CT 27.1 [8.3] 2011829 tba
S 27.6 [8.4] tba tba
1,506 1,254 93.9 UT 26.7 [8.1] 1,672 [759.1] tba tba
225 188
CT 27.0 [8.2] tba tba
S 27.6 [8.4] tba tba
2,292 1,909 61.7 1,654 [750.9]
UT 26.7 [8.1] tba 2011730
S 27.6 [8.4] tba tba
2,685 2,237 52.7 1,716 [779.1]
UT 26.7 [8.1] 2011738 100033720
S 30.4 [9.3] tba tba
1,237 1,030 127.1 UT 29.5 [9.0] 1,890 [858.1] 2011739 tba
CT 29.7 [9.1] 2011830 tba
S 30.4 [9.3] tba tba
250 1,673 208 1,394 94.0 UT 29.5 [9.0] 1,846 [838.1] tba tba
CT 29.7 [9.1] tba tba
S 30.4 [9.3] tba tba
2,547 2,122 61.7 UT 29.5 [9.0] 1,840 [835.4] 100033715 100089108
CT 29.7 [9.1] tba tba
† to be assigned
Return to Motors
562 Dominator Motors
Return to Motors
562 Dominator* Motors—RK-XD Type (continued)
Frequency, 60 Hz Frequency, 50 Hz
Power Voltage, V Power Voltage, V Current, A Type Length, Weight, Carbon Steel Redalloy* Alloy
Rating, hp Rating, hp ft [m] lbm [kg] Part Number Part Number
412 343 132.0 UT 9.1 [2.8] 656 [297.8] 2008120 2008339
842 702 64.5 UT 9.1 [2.8] 656 [297.8] 2008121 2008340
950 792 57.0 UT 9.1 [2.8] 656 [297.8] 2008122 2008341
1,165 971 46.5 UT 9.1 [2.8] 656 [297.8] 2008123 2008342
1,273 1,061 42.5 UT 9.1 [2.8] 656 [297.8] 2008124 2008343
1,380 1,150 39.5 UT 9.1 [2.8] 656 [297.8] 2008125 2008344
1,488 1,240 36.5 UT 9.1 [2.8] 656 [297.8] 2008126 2008345
2,133 1,777 25.5 UT 9.1 [2.8] 656 [297.8] 2008127 1193218
90 75
412 343 132.0 S 10.0 [3.1] 724 [328.7] 2008807 2009015
842 702 64.5 S 10.0 [3.1] 724 [328.7] 2008808 2009016
950 792 57.0 S 10.0 [3.1] 724 [328.7] 2008809 2009017
1,165 971 46.5 S 10.0 [3.1] 724 [328.7] 2008810 2009018
1,273 1,061 42.5 S 10.0 [3.1] 724 [328.7] 2008811 2009019
1,380 1,150 39.5 S 10.0 [3.1] 724 [328.7] 2008812 2009020
1,488 1,240 36.5 S 10.0 [3.1] 724 [328.7] 2008813 2009021
2,133 1,777 25.5 S 10.0 [3.1] 724 [328.7] 2008814 2009022
485 404 130.0 UT 10.3 [3.1] 743 [337.3] 2008128 2008347
865 721 73.0 UT 10.3 [3.1] 743 [337.3] 2008129 2008348
1,118 932 56.5 UT 10.3 [3.1] 743 [337.3] 2008130 2008349
1,371 1,142 46.0 UT 10.3 [3.1] 743 [337.3] 2008131 2008350
105 88
485 404 130.0 S 11.2 [3.4] 812 [368.6] 2008815 2009023
865 721 73.0 S 11.2 [3.4] 812 [368.6] 2008816 2009024
1,118 932 56.5 S 11.2 [3.4] 812 [368.6] 2008817 2009025
1,371 1,142 46.0 S 11.2 [3.4] 812 [368.6] 2008818 2009026
837 697 86.5 UT 11.2 [3.4] 807 [366.4] 2008132 2008351
980 817 73.5 UT 11.2 [3.4] 807 [366.4] 2008133 2008352
1,267 1,056 57.0 UT 11.2 [3.4] 807 [366.4] 2008134 2008353
1,410 1,175 51.0 UT 11.2 [3.4] 807 [366.4] 2008135 2008354
2,270 1,892 32.0 UT 11.2 [3.4] 807 [366.4] 2008136 2008355
2,558 2,132 28.0 UT 11.2 [3.4] 807 [366.4] 2008137 2008356
4,279 3,566 17.0 UT 11.2 [3.4] 807 [366.4] 2008138 2008357
120 100
837 697 86.5 S 12.1 [3.7] 876 [397.7] 2008819 2009028
980 817 73.5 S 12.1 [3.7] 876 [397.7] 2008820 2009029
1,267 1,056 57.0 S 12.1 [3.7] 876 [397.7] 2008821 2009030
1,410 1,175 51.0 S 12.1 [3.7] 876 [397.7] 2008822 2009031
2,270 1,892 32.0 S 12.1 [3.7] 876 [397.7] 2008823 2009032
2,558 2,132 28.0 S 12.1 [3.7] 876 [397.7] 2008824 2009033
4,279 3,566 17.0 S 12.1 [3.7] 876 [397.7] 2008825 2009034
948 790 85.5 UT 12.4 [3.8] 895 [406.3] 2008554 2008716
1,110 925 73.0 UT 12.4 [3.8] 895 [406.3] 2008555 2008717
1,435 1,196 56.5 UT 12.4 [3.8] 895 [406.3] 2008556 2008718
1,760 1,467 46.0 UT 12.4 [3.8] 895 [406.3] 2008557 2008719
135 113
948 790 85.5 S 13.3 [4.1] 963 [437.2] 2009136 2009298
1,110 925 73.0 S 13.3 [4.1] 963 [437.2] 2009137 2009299
1,435 1,196 56.5 S 13.3 [4.1] 963 [437.2] 2009138 2009300
1,760 1,467 46.0 S 13.3 [4.1] 963 [437.2] 2009139 2009301
Return to Motors
562 Dominator* Motors—RK-XD Type (continued)
Frequency, 60 Hz Frequency, 50 Hz
Power Voltage, V Power Voltage, V Current, A Type Length, Weight, Carbon Steel Redalloy* Alloy
Rating, hp Rating, hp ft [m] lbm [kg] Part Number Part Number
867 722 104.0 UT 13.2 [4.0] 959 [435.4] 2008558 2008720
1,225 1,021 73.5 UT 13.2 [4.0] 959 [435.4] 2008559 2008721
1,404 1,170 64.5 UT 13.2 [4.0] 959 [435.4] 2008560 2008722
2,300 1,917 39.5 UT 13.2 [4.0] 959 [435.4] 2008561 2008723
2,659 2,216 34.0 UT 13.2 [4.0] 959 [435.4] 2008562 2008724
3,197 2,264 28.0 UT 13.2 [4.0] 959 [435.4] 2008563 2008725
4,273 3,561 21.0 UT 13.2 [4.0] 959 [435.4] 2008564 2008726
150 125
867 722 104.0 S 14.2 [4.3] 1,027 [466.3] 2009140 2009302
1,225 1,021 73.5 S 14.2 [4.3] 1,027 [466.3] 2009141 2009303
1,404 1,170 64.5 S 14.2 [4.3] 1,027 [466.3] 2009142 2009304
2,300 1,917 39.5 S 14.2 [4.3] 1,027 [466.3] 2009143 2009305
2,659 2,216 34.0 S 14.2 [4.3] 1,027 [466.3] 2009144 2009306
3,197 2,264 28.0 S 14.2 [4.3] 1,027 [466.3] 2009145 2009307
4,273 3,561 21.0 S 14.2 [4.3] 1,027 [466.3] 2009146 2009308
1,355 1,129 73.5 UT 14.5 [4.4] 1,046 [474.9] 2008565 2008727
1,752 1,460 56.5 UT 14.5 [4.4] 1,046 [474.9] 2008566 2008728
2,148 1,790 46.0 UT 14.5 [4.4] 1,046 [474.9] 2008567 2008729
165 138
1,355 1,129 73.5 S 15.4 [4.7] 1,115 [506.2] 2009147 2009309
1,752 1,460 56.5 S 15.4 [4.7] 1,115 [506.2] 2009148 2009310
2,148 1,790 46.0 S 15.4 [4.7] 1,115 [506.2] 2009149 2009311
1,040 867 104.0 UT 15.3 [4.7] 1,110 [503.9] 2008153 2008372
1,255 1,046 86.5 UT 15.3 [4.7] 1,110 [503.9] 2008154 2008373
1,685 1,404 64.5 UT 15.3 [4.7] 1,110 [503.9] 2008155 2008374
1,900 1,583 57.0 UT 15.3 [4.7] 1,110 [503.9] 2008156 2008375
2,115 1,762 51.0 UT 15.3 [4.7] 1,110 [503.9] 2008157 2008376
2,545 2,121 42.5 UT 15.3 [4.7] 1,110 [503.9] 2008158 2008377
3,190 2,658 34.0 UT 15.3 [4.7] 1,110 [503.9] 2008159 2008378
4,051 3,376 26.5 UT 15.3 [4.7] 1,110 [503.9] 2008160 2008379
180 150
1,040 867 104.0 S 16.3 [5.0] 1,179 [535.3] 2008840 2009049
1,255 1,046 86.5 S 16.3 [5.0] 1,179 [535.3] 2008841 2009050
1,685 1,404 64.5 S 16.3 [5.0] 1,179 [535.3] 2008842 2009051
1,900 1,583 57.0 S 16.3 [5.0] 1,179 [535.3] 2008843 2009052
2,115 1,762 51.0 S 16.3 [5.0] 1,179 [535.3] 2008844 2009053
2,545 2,121 42.5 S 16.3 [5.0] 1,179 [535.3] 2008845 2009054
3,190 2,658 34.0 S 16.3 [5.0] 1,179 [535.3] 2008846 2009055
4,051 3,376 26.5 S 16.3 [5.0] 1,179 [535.3] 2008847 2009056
Return to Motors
562 Dominator* Motors—RK-XD Type (continued)
Frequency, 60 Hz Frequency, 50 Hz
Power Voltage, V Power Voltage, V Current, A Type Length, Weight, Carbon Steel Redalloy* Alloy
Rating, hp Rating, hp ft [m] lbm [kg] Part Number Part Number
1,213 1,011 104.0 UT 17.4 [5.3] 1,262 [572.9] 2008161 2008380
2,468 2,057 51.0 UT 17.4 [5.3] 1,262 [572.9] 2008162 2008381
3,722 3,102 34.0 UT 17.4 [5.3] 1,262 [572.9] 2008163 2008382
210 175
1,213 1,011 104.0 S 18.4 [5.6] 1,331 [604.3] 2008848 2009057
2,468 2,057 51.0 S 18.4 [5.6] 1,331 [604.3] 2008849 2009058
3,722 3,102 34.0 S 18.4 [5.6] 1,331 [604.3] 2008850 2009059
1,100 917 131.0 UT 19.5 [5.9] 1,414 [642.0] 2008164 2008383
1,386 1,155 104.0 UT 19.5 [5.9] 1,414 [642.0] 2008165 2008384
2,247 1,872 64.5 UT 19.5 [5.9] 1,414 [642.0] 2008168 2008385
2,534 2,112 57.0 UT 19.5 [5.9] 1,414 [642.0] 2008169 2008386
4,255 3,546 34.0 UT 19.5 [5.9] 1,414 [642.0] 2008170 2008387
1,100 917 131.0 CT 19.7 [6.0] 1,423 [646.0] 2009704 2009728
240 200
1,386 1,155 104.0 CT 19.7 [6.0] 1,423 [646.0] 2009705 2009729
1,100 917 131.0 S 20.5 [6.3] 1,482 [672.8] 2008851 2009060
1,386 1,155 104.0 S 20.5 [6.3] 1,482 [672.8] 2008852 2009061
2,247 1,872 64.5 S 20.5 [6.3] 1,482 [672.8] 2008853 2009062
2,534 2,112 57.0 S 20.5 [6.3] 1,482 [672.8] 2008854 2009063
4,255 3,546 34.0 S 20.5 [6.3] 1,482 [672.8] 2008855 2009064
1,237 1,031 131.0 UT 21.6 [6.6] 1,565 [710.5] 2008171 2008388
1,560 1,300 104.0 UT 21.6 [6.6] 1,565 [710.5] 2008172 2008389
1,882 1,568 86.5 UT 21.6 [6.6] 1,565 [710.5] 2008173 2008390
2,205 1,837 73.5 UT 21.6 [6.6] 1,565 [710.5] 2008174 2008391
2,528 2,107 64.5 UT 21.6 [6.6] 1,565 [710.5] 2008175 2008392
1,237 1,031 131.0 CT 21.8 [6.6] 1,575 [715.1] 2009706 2009730
270 1,560 225 1,300 104.0 CT 21.8 [6.6] 1,575 [715.1] 2009707 2009731
1,882 1,568 86.5 CT 21.8 [6.6] 1,575 [715.1] 2009708 2009732
1,237 1,031 131.0 S 22.6 [6.9] 1,634 [741.8] 2008856 2009065
1,560 1,300 104.0 S 22.6 [6.9] 1,634 [741.8] 2008857 2009066
1,882 1,568 86.5 S 22.6 [6.9] 1,634 [741.8] 2008858 2009067
2,205 1,837 73.5 S 22.6 [6.9] 1,634 [741.8] 2008859 2009068
2,528 2,107 64.5 S 22.6 [6.9] 1,634 [741.8] 2008860 2009069
1,374 1,145 131.0 UT 23.7 [7.2] 1,717 [779.5] 2008176 2008488
1,733 1,444 104.0 UT 23.7 [7.2] 1,717 [779.5] 2008177 2008489
2,091 1,742 86.5 UT 23.7 [7.2] 1,717 [779.5] 2008178 2008490
2,450 2,042 73.5 UT 23.7 [7.2] 1,717 [779.5] 2008179 2008491
4,242 3,535 42.5 UT 23.7 [7.2] 1,717 [779.5] 2008180 2008492
1,374 1,145 131.0 CT 23.9 [7.3] 1,726 [783.6] 2009709 2009764
300 1,733 250 1,444 104.0 CT 23.9 [7.3] 1,726 [783.6] 2009710 2009765
2091 1,742 86.5 CT 23.9 [7.3] 1,726 [783.6] 2009711 2009766
1,374 1,145 131.0 S 24.7 [7.5] 1,785 [810.4] 2008861 2009070
1,733 1,444 104.0 S 24.7 [7.5] 1,785 [810.4] 2008862 2009071
2,091 1,742 86.5 S 24.7 [7.5] 1,785 [810.4] 2008863 2009072
2,450 2,042 73.5 S 24.7 [7.5] 1,785 [810.4] 2008864 2009073
4,242 3,535 42.5 S 24.7 [7.5] 1,785 [810.4] 2008865 2009074
Return to Motors
562 Dominator* Motors—RK-XD Type (continued)
Frequency, 60 Hz Frequency, 50 Hz
Power Voltage, V Power Voltage, V Current, A Type Length, Weight, Carbon Steel Redalloy* Alloy
Rating, hp Rating, hp ft [m] lbm [kg] Part Number Part Number
1,512 1,260 131.0 UT 25.8 [7.9] 1,868 [848.1] 2008181 2008493
1,906 1,588 104.0 UT 25.8 [7.9] 1,868 [848.1] 2008182 2008484
2,695 2,246 73.5 UT 25.8 [7.9] 1,868 [848.1] 2008183 2008495
3,484 2,903 57.0 UT 25.8 [7.9] 1,868 [848.1] 2008184 2008496
3,878 3,232 51.0 UT 25.8 [7.9] 1,868 [848.1] 2008185 2008497
1,512 1,260 131.0 CT 25.9 [7.9] 1,878 [852.6] 2009712 2009736
330 275
1,906 1,588 104.0 CT 25.9 [7.9] 1,878 [852.6] 2009713 2009737
1,512 1,260 131.0 S 26.8 [8.2] 1,937 [879.4] 2008866 2009075
1,906 1,588 104.0 S 26.8 [8.2] 1,937 [879.4] 2008867 2009076
2,695 2,246 73.5 S 26.8 [8.2] 1,937 [879.4] 2008868 2009077
3,484 2,903 57.0 S 26.8 [8.2] 1,937 [879.4] 2008869 2009078
3,878 3,232 51.0 S 26.8 [8.2] 1,937 [879.4] 2008870 2009079
1,649 1,374 131.0 UT 27.9 [8.5] 2,020 [917.1] 2008186 2008405
2,080 1,733 104.0 UT 27.9 [8.5] 2,020 [917.1] 2008187 2008406
2,510 2,092 86.5 UT 27.9 [8.5] 2,020 [917.1] 2008188 2008407
3,370 2,808 64.5 UT 27.9 [8.5] 2,020 [917.1] 2008189 2008408
4,230 3,525 51.0 UT 27.9 [8.5] 2,020 [917.1] 2008190 2008409
1,649 1,374 131.0 CT 28.0 [8.5] 2,030 [921.6] 2009726 2009738
360 300
2,080 1,733 104.0 CT 28.0 [8.5] 2,030 [921.6] 2009727 2009739
1,649 1,374 131.0 S 28.9 [8.8] 2,088 [948.0] 2008871 2009080
2,080 1,733 104.0 S 28.9 [8.8] 2,088 [948.0] 2008872 2009081
2,510 2,092 86.5 S 28.9 [8.8] 2,088 [948.0] 2008873 2009082
3,370 2,808 64.5 S 28.9 [8.8] 2,088 [948.0] 2008874 2009083
4,230 3,525 51.0 S 28.9 [8.8] 2,088 [948.0] 2008875 2009084
1,321 1,101 150.0 UT 30.1 [9.2] 2,171 [985.6] 2008472 2008503
1,787 1,489 131.0 UT 30.1 [9.2] 2,171 [985.6] 2008473 2008504
2,253 1,877 104.0 UT 30.1 [9.2] 2,171 [985.6] 2008193 2008412
2,718 2,265 86.5 UT 30.1 [9.2] 2,171 [985.6] 2008194 2008413
3,650 3,042 64.5 UT 30.1 [9.2] 2,171 [985.6] 2008195 2008414
1,321 1,101 150.0 CT 30.1 [9.2] 2,181 [990.2] 2009747 2009771
390 325
1,787 1,489 131.0 CT 30.1 [9.2] 2,181 [990.2] 2009748 2009772
1,321 1,101 150.0 S 30.9 [9.4] 2,240 [1,017.0] 2008876 2009085
1,787 1,489 131.0 S 30.9 [9.4] 2,240 [1,017.0] 2008877 2009086
2,253 1,877 104.0 S 30.9 [9.4] 2,240 [1,017.0] 2008878 2009087
2,718 2,265 86.5 S 30.9 [9.4] 2,240 [1,017.0] 2008879 2009088
3,650 3,042 64.5 S 30.9 [9.4] 2,240 [1,017.0] 2008880 2009089
1,924 1,603 131.0 UT 32.1 [9.8] 2,323 [1,054.6] 2008446 2008508
2,426 2,022 104.0 UT 32.1 [9.8] 2,323 [1,054.6] 2008197 2008416
2,928 2,440 86.5 UT 32.1 [9.8] 2,323 [1,054.6] 2008198 2008417
3,430 2,858 73.5 UT 32.1 [9.8] 2,323 [1,054.6] 2008199 2008418
3,932 3,277 64.5 UT 32.1 [9.8] 2,323 [1,054.6] 2008200 2008419
420 1,924 350 1,603 131.0 CT 32.2 [9.8] 2,333 [1,059.2] 2009749 2009773
1,924 1,603 131.0 S 33.0 [10.1] 2,391 [1,085.5] 2008881 2009090
2,426 2,022 104.0 S 33.0 [10.1] 2,391 [1,085.5] 2008883 2009091
2,928 2,440 86.5 S 33.0 [10.1] 2,391 [1,085.5] 2008885 2009092
3,430 2,858 73.5 S 33.0 [10.1] 2,391 [1,085.5] 2008886 2009093
3,932 3,277 64.5 S 33.0 [10.1] 2,391 [1,085.5] 2008887 2009094
Return to Motors
562 Dominator* Motors—RK-XD Type (continued)
Frequency, 60 Hz Frequency, 50 Hz
Power Voltage, V Power Voltage, V Current, A Type Length, Weight, Carbon Steel Redalloy* Alloy
Rating, hp Rating, hp ft [m] lbm [kg] Part Number Part Number
1,524 1,270 178.0 UT 34.2 [10.4] 2,474 [1,123.2] 2008451 2008513
2,062 1,718 131.0 UT 34.2 [10.4] 2,474 [1,123.2] 2008452 2008514
2,600 2,167 104.0 UT 34.2 [10.4] 2,474 [1,123.2] 2008203 2008422
3,137 2,614 86.5 UT 34.2 [10.4] 2,474 [1,123.2] 2008204 2008423
3,675 3,062 73.5 UT 34.2 [10.4] 2,474 [1,123.2] 2008205 2008424
4,213 3,511 64.5 UT 34.2 [10.4] 2,474 [1,123.2] 2008206 2008425
1,524 1,270 178.0 CT 34.3 [10.5] 2,484 [1,127.7] 2009750 2009774
450 375
2,062 1,718 131.0 CT 34.3 [10.5] 2,484 [1,127.7] 2009751 2009775
1,524 1,270 178.0 S 35.1 [10.7] 2,543 [1,154.5] 2008888 2009095
2,062 1,718 131.0 S 35.1 [10.7] 2,543 [1,154.5] 2008889 2009096
2,600 2,167 104.0 S 35.1 [10.7] 2,543 [1,154.5] 2008890 2009097
3,137 2,614 86.5 S 35.1 [10.7] 2,543 [1,154.5] 2008891 2009098
3,675 3,062 73.5 S 35.1 [10.7] 2,543 [1,154.5] 2008892 2009099
4,213 3,511 64.5 S 35.1 [10.7] 2,543 [1,154.5] 2008893 2009100
Return to Motors
562 Dominator Motors
Return to Motors
562 Dominator* Motors—RX-XD Type (continued)
Frequency, 60 Hz Frequency, 50 Hz
Power Voltage, V Power Voltage, V Current, A Type Length, Weight, Carbon Steel Redalloy* Alloy
Rating, hp Rating, hp ft [m] lbm [kg] Part Number Part Number
412 343 132.0 UT 9.1 [2.8] 656 [297.8] 2008535 2008697
842 702 64.5 UT 9.1 [2.8] 656 [297.8] 2008536 2008698
950 792 57.0 UT 9.1 [2.8] 656 [297.8] 2008537 2008699
1,165 971 46.5 UT 9.1 [2.8] 656 [297.8] 2008538 2008700
1,273 1,061 42.5 UT 9.1 [2.8] 656 [297.8] 2008539 2008701
1,380 1,150 39.5 UT 9.1 [2.8] 656 [297.8] 2008540 2008702
1,488 1,240 36.5 UT 9.1 [2.8] 656 [297.8] 2008541 2008703
2,133 1,777 25.5 UT 9.1 [2.8] 656 [297.8] 2008542 2008704
90 75
412 343 132.0 S 10.0 [3.1] 724 [328.7] 2009117 2009279
842 702 64.5 S 10.0 [3.1] 724 [328.7] 2009118 2009280
950 792 57.0 S 10.0 [3.1] 724 [328.7] 2009119 2009281
1,165 971 46.5 S 10.0 [3.1] 724 [328.7] 2009120 2009282
1,273 1,061 42.5 S 10.0 [3.1] 724 [328.7] 2009121 2009293
1,380 1,150 39.5 S 10.0 [3.1] 724 [328.7] 2009122 2009284
1,488 1,240 36.5 S 10.0 [3.1] 724 [328.7] 2009123 2009285
2,133 1,777 25.5 S 10.0 [3.1] 724 [328.7] 2009124 2009286
485 404 130.0 UT 10.3 [3.1] 743 [337.3] 2008543 2008705
865 721 73.0 UT 10.3 [3.1] 743 [337.3] 2008544 2008706
1,118 932 56.5 UT 10.3 [3.1] 743 [337.3] 2008545 2008707
1,371 1,142 46.0 UT 10.3 [3.1] 743 [337.3] 2008546 2008708
105 88
485 404 130.0 S 11.2 [3.4] 812 [368.6] 2009125 2009287
865 721 73.0 S 11.2 [3.4] 812 [368.6] 2009126 2009288
1,118 932 56.5 S 11.2 [3.4] 812 [368.6] 2009127 2009289
1,371 1,142 46.0 S 11.2 [3.4] 812 [368.6] 2009128 2009290
837 697 86.5 UT 11.2 [3.4] 807 [366.4] 2008547 2008709
980 817 73.5 UT 11.2 [3.4] 807 [366.4] 2008548 2008710
1,267 1,056 57.0 UT 11.2 [3.4] 807 [366.4] 2008549 2008711
1,410 1,175 51.0 UT 11.2 [3.4] 807 [366.4] 2008550 2008712
2,270 1,892 32.0 UT 11.2 [3.4] 807 [366.4] 2008551 2008713
2,558 2,132 28.0 UT 11.2 [3.4] 807 [366.4] 2008552 2008714
4,279 3,566 17.0 UT 11.2 [3.4] 807 [366.4] 2008553 2008715
120 100
837 697 86.5 S 12.1 [3.7] 876 [397.7] 2009129 2009291
980 817 73.5 S 12.1 [3.7] 876 [397.7] 2009130 2009292
1,267 1,056 57.0 S 12.1 [3.7] 876 [397.7] 2009131 2009293
1,410 1,175 51.0 S 12.1 [3.7] 876 [397.7] 2009132 2009294
2,270 1,892 32.0 S 12.1 [3.7] 876 [397.7] 2009133 2009295
2,558 2,132 28.0 S 12.1 [3.7] 876 [397.7] 2009134 2009296
4,279 3,566 17.0 S 12.1 [3.7] 876 [397.7] 2009135 2009297
948 790 85.5 UT 12.4 [3.8] 895 [406.3] 2008554 2008716
1,110 925 73.0 UT 12.4 [3.8] 895 [406.3] 2008555 2008717
1,435 1,196 56.5 UT 12.4 [3.8] 895 [406.3] 2008556 2008718
1,760 1,467 46.0 UT 12.4 [3.8] 895 [406.3] 2008557 2008719
135 113
948 790 85.5 S 13.3 [4.1] 963 [437.2] 2009136 2009298
1,110 925 73.0 S 13.3 [4.1] 963 [437.2] 2009137 2009299
1,435 1,196 56.5 S 13.3 [4.1] 963 [437.2] 2009138 2009300
1,760 1,467 46.0 S 13.3 [4.1] 963 [437.2] 2009139 2009301
Return to Motors
562 Dominator* Motors—RX-XD Type (continued)
Frequency, 60 Hz Frequency, 50 Hz
Power Voltage, V Power Voltage, V Current, A Type Length, Weight, Carbon Steel Redalloy* Alloy
Rating, hp Rating, hp ft [m] lbm [kg] Part Number Part Number
867 722 104.0 UT 13.2 [4.0] 959 [435.4] 2008558 2008720
1,225 1,021 73.5 UT 13.2 [4.0] 959 [435.4] 2008559 2008721
1,404 1,170 64.5 UT 13.2 [4.0] 959 [435.4] 2008560 2008722
2,300 1,917 39.5 UT 13.2 [4.0] 959 [435.4] 2008561 2008723
2,659 2,216 34.0 UT 13.2 [4.0] 959 [435.4] 2008562 2008724
3,197 2,264 28.0 UT 13.2 [4.0] 959 [435.4] 2008563 2008725
4,273 3,561 21.0 UT 13.2 [4.0] 959 [435.4] 2008564 2008726
150 125
867 722 104.0 S 14.2 [4.3] 1,027 [466.3] 2009140 2009302
1,225 1,021 73.5 S 14.2 [4.3] 1,027 [466.3] 2009141 2009303
1,404 1,170 64.5 S 14.2 [4.3] 1,027 [466.3] 2009142 2009304
2,300 1,917 39.5 S 14.2 [4.3] 1,027 [466.3] 2009143 2009305
2,659 2,216 34.0 S 14.2 [4.3] 1,027 [466.3] 2009144 2009306
3,197 2,264 28.0 S 14.2 [4.3] 1,027 [466.3] 2009145 2009307
4,273 3,561 21.0 S 14.2 [4.3] 1,027 [466.3] 2009146 2009308
1,355 1,129 73.5 UT 14.5 [4.4] 1,046 [474.9] 2008565 2008727
1,752 1,460 56.5 UT 14.5 [4.4] 1,046 [474.9] 2008566 2008728
2,148 1,790 46.0 UT 14.5 [4.4] 1,046 [474.9] 2008567 2008729
165 138
1,355 1,129 73.5 S 15.4 [4.7] 1,115 [506.2] 2009147 2009309
1,752 1,460 56.5 S 15.4 [4.7] 1,115 [506.2] 2009148 2009310
2,148 1,790 46.0 S 15.4 [4.7] 1,115 [506.2] 2009149 2009311
1,040 867 104.0 UT 15.3 [4.7] 1,110 [503.9] 2008570 2008730
1,255 1,046 86.5 UT 15.3 [4.7] 1,110 [503.9] 2008571 2008731
1,685 1,404 64.5 UT 15.3 [4.7] 1,110 [503.9] 2008572 2008732
1,900 1,583 57.0 UT 15.3 [4.7] 1,110 [503.9] 2008573 2008733
2,115 1,762 51.0 UT 15.3 [4.7] 1,110 [503.9] 2008574 2008734
2,545 2,121 42.5 UT 15.3 [4.7] 1,110 [503.9] 2008575 2008735
3,190 2,658 34.0 UT 15.3 [4.7] 1,110 [503.9] 2008576 2008736
4,051 3,376 26.5 UT 15.3 [4.7] 1,110 [503.9] 2008577 2008737
180 150
1,040 867 104.0 S 16.3 [5.0] 1,179 [535.3] 2009150 2009312
1,255 1,046 86.5 S 16.3 [5.0] 1,179 [535.3] 2009151 2009313
1,685 1,404 64.5 S 16.3 [5.0] 1,179 [535.3] 2009152 2009314
1,900 1,583 57.0 S 16.3 [5.0] 1,179 [535.3] 2009153 2009315
2,115 1,762 51.0 S 16.3 [5.0] 1,179 [535.3] 2009154 2009316
2,545 2,121 42.5 S 16.3 [5.0] 1,179 [535.3] 2009155 2009317
3,190 2,658 34.0 S 16.3 [5.0] 1,179 [535.3] 2009156 2009318
4,051 3,376 26.5 S 16.3 [5.0] 1,179 [535.3] 2009157 2009319
1,213 1,011 104.0 UT 17.4 [5.3] 1,262 [572.9] 2008161 2008380
2,468 2,057 51.0 UT 17.4 [5.3] 1,262 [572.9] 2008162 2008381
3,722 3,102 34.0 UT 17.4 [5.3] 1,262 [572.9] 2008163 2008382
210 175
1,213 1,011 104.0 S 18.4 [5.6] 1,331 [604.3] 2008848 2009057
2,468 2,057 51.0 S 18.4 [5.6] 1,331 [604.3] 2008849 2009058
3,722 3,102 34.0 S 18.4 [5.6] 1,331 [604.3] 2008850 2009059
Return to Motors
562 Dominator* Motors—RX-XD Type (continued)
Frequency, 60 Hz Frequency, 50 Hz
Power Voltage, V Power Voltage, V Current, A Type Length, Weight, Carbon Steel Redalloy* Alloy
Rating, hp Rating, hp ft [m] lbm [kg] Part Number Part Number
1,100 917 131.0 UT 19.5 [5.9] 1,414 [642.0] 2008581 2008741
1,386 1,155 104.0 UT 19.5 [5.9] 1,414 [642.0] 2008582 2008742
2,247 1,872 64.5 UT 19.5 [5.9] 1,414 [642.0] 2008583 2008744
2,534 2,112 57.0 UT 19.5 [5.9] 1,414 [642.0] 2008584 2008745
4,255 3,546 34.0 UT 19.5 [5.9] 1,414 [642.0] 2008585 tba†
1,100 917 131.0 CT 19.7 [6.0] 1,423 [646.0] 2009776 2009795
240 200
1,386 1,155 104.0 CT 19.7 [6.0] 1,423 [646.0] 2009777 2009796
1,100 917 131.0 S 20.5 [6.3] 1,482 [672.8] 2009161 2009323
1,386 1,155 104.0 S 20.5 [6.3] 1,482 [672.8] 2009162 2009324
2,247 1,872 64.5 S 20.5 [6.3] 1,482 [672.8] 2009163 2009325
2,534 2,112 57.0 S 20.5 [6.3] 1,482 [672.8] 2009164 2009326
4,255 3,546 34.0 S 20.5 [6.3] 1,482 [672.8] 2009165 2009327
1,237 1,031 131.0 UT 21.6 [6.6] 1,565 [710.5] 2008586 2008746
1,560 1,300 104.0 UT 21.6 [6.6] 1,565 [710.5] 2008587 2008747
1,882 1,568 86.5 UT 21.6 [6.6] 1,565 [710.5] 2008588 2008748
2,205 1,837 73.5 UT 21.6 [6.6] 1,565 [710.5] 2008589 2008749
2,528 2,107 64.5 UT 21.6 [6.6] 1,565 [710.5] 2008590 2008750
1,237 1,031 131.0 CT 21.8 [6.6] 1,575 [715.1] 2009778 2009797
270 1,560 225 1,300 104.0 CT 21.8 [6.6] 1,575 [715.1] 2009779 2009798
1,882 1,568 86.5 CT 21.8 [6.6] 1,575 [715.1] 2009835 2009799
1,237 1,031 131.0 S 22.6 [6.9] 1,634 [741.8] 2009166 2009328
1,560 1,300 104.0 S 22.6 [6.9] 1,634 [741.8] 2009167 2009329
1,882 1,568 86.5 S 22.6 [6.9] 1,634 [741.8] 2009168 2009330
2,205 1,837 73.5 S 22.6 [6.9] 1,634 [741.8] 2009169 2009331
2,528 2,107 64.5 S 22.6 [6.9] 1,634 [741.8] 2009170 2009332
1,374 1,145 131.0 UT 23.7 [7.2] 1,717 [779.5] 2008591 2008751
1,733 1,444 104.0 UT 23.7 [7.2] 1,717 [779.5] 2008592 2008752
2,091 1,742 86.5 UT 23.7 [7.2] 1,717 [779.5] 2008593 2008753
2,450 2,042 73.5 UT 23.7 [7.2] 1,717 [779.5] 2008594 2008754
4,242 3,535 42.5 UT 23.7 [7.2] 1,717 [779.5] 2008595 2008755
1,374 1,145 131.0 CT 23.9 [7.3] 1,726 [783.6] 2009780 2009800
300 1,733 250 1,444 104.0 CT 23.9 [7.3] 1,726 [783.6] 2009781 2009801
2,091 1,742 86.5 CT 23.9 [7.3] 1,726 [783.6] 2009782 2009802
1,374 1,145 131.0 S 24.7 [7.5] 1,785 [810.4] 2009171 2009333
1,733 1,444 104.0 S 24.7 [7.5] 1,785 [810.4] 2009172 2009334
2,091 1,742 86.5 S 24.7 [7.5] 1,785 [810.4] 2009173 2009335
2,450 2,042 73.5 S 24.7 [7.5] 1,785 [810.4] 2009174 2009336
4,242 3,535 42.5 S 24.7 [7.5] 1,785 [810.4] 2009175 2009337
† to be assigned
Return to Motors
562 Dominator* Motors—RX-XD Type (continued)
Frequency, 60 Hz Frequency, 50 Hz
Power Voltage, V Power Voltage, V Current, A Type Length, Weight, Carbon Steel Redalloy* Alloy
Rating, hp Rating, hp ft [m] lbm [kg] Part Number Part Number
1,512 1,260 131.0 UT 25.8 [7.9] 1,868 [848.1] 2008596 2008756
1,906 1,588 104.0 UT 25.8 [7.9] 1,868 [848.1] 2008597 2008757
2,695 2,246 73.5 UT 25.8 [7.9] 1,868 [848.1] 2008598 2008758
3,484 2,903 57.0 UT 25.8 [7.9] 1,868 [848.1] 2008599 2008759
3,878 3,232 51.0 UT 25.8 [7.9] 1,868 [848.1] 2008600 2008760
1,512 1,260 131.0 CT 25.9 [7.9] 1,878 [852.6] 2009783 2009803
330 275
1,906 1,588 104.0 CT 25.9 [7.9] 1,878 [852.6] 2009784 2009804
1,512 1,260 131.0 S 26.8 [8.2] 1,937 [879.4] 2009176 2009338
1,906 1,588 104.0 S 26.8 [8.2] 1,937 [879.4] 2009178 2009339
2,695 2,246 73.5 S 26.8 [8.2] 1,937 [879.4] 2009179 2009340
3,484 2,903 57.0 S 26.8 [8.2] 1,937 [879.4] 2009180 2009341
3,878 3,232 51.0 S 26.8 [8.2] 1,937 [879.4] 2009181 2009342
1,649 1,374 131.0 UT 27.9 [8.5] 2,020 [917.1] 2011002 2011022
2,080 1,733 104.0 UT 27.9 [8.5] 2,020 [917.1] 2011003 2011023
2,510 2,092 86.5 UT 27.9 [8.5] 2,020 [917.1] 2011004 2011024
3,370 2,808 64.5 UT 27.9 [8.5] 2,020 [917.1] 2011005 2011025
4,230 3,525 51.0 UT 27.9 [8.5] 2,020 [917.1] 2011006 2011026
1,649 1,374 131.0 CT 28.0 [8.5] 2,030 [921.6] 2011146 2011150
360 300
2,080 1,733 104.0 CT 28.0 [8.5] 2,030 [921.6] 2011147 2011151
1,649 1,374 131.0 S 28.9 [8.8] 2,088 [948.0] 2010920 2010962
2,080 1,733 104.0 S 28.9 [8.8] 2,088 [948.0] 2010921 2010963
2,510 2,092 86.5 S 28.9 [8.8] 2,088 [948.0] 2010922 2010964
3,370 2,808 64.5 S 28.9 [8.8] 2,088 [948.0] 2010923 2010965
4,230 3,525 51.0 S 28.9 [8.8] 2,088 [948.0] 010924 2010966
1,321 1,101 150.0 UT 30.0 [9.2] 2,171 [985.6] 2011037 2011057
1,787 1,489 131.0 UT 30.0 [9.2] 2,171 [985.6] 2011038 2011058
2,253 1,877 104.0 UT 30.0 [9.2] 2,171 [985.6] 2011010 2011029
2,718 2,265 86.5 UT 30.0 [9.2] 2,171 [985.6] 2011011 2011030
3,650 3,042 64.5 UT 30.0 [9.2] 2,171 [985.6] 2011012 2011031
1,321 1,101 150.0 CT 30.1 [9.2] 2,181 [990.2] 2011154 2011168
390 325
1,787 1,489 131.0 CT 30.1 [9.2] 2,181 [990.2] 2011155 2011169
1,321 1,101 150.0 S 30.9 [9.4] 2,240 [1,017.0] 2010925 2010967
1,787 1,489 131.0 S 30.9 [9.4] 2,240 [1,017.0] 2010926 2010968
2,253 1,877 104.0 S 30.9 [9.4] 2,240 [1,017.0] 2010927 2010969
2,718 2,265 86.5 S 30.9 [9.4] 2,240 [1,017.0] 2010928 2010970
3,650 3,042 64.5 S 30.9 [9.4] 2,240 [1,017.0] 2010929 2010971
Return to Motors
562 Dominator* Motors—RX-XD Type (continued)
Frequency, 60 Hz Frequency, 50 Hz
Power Voltage, V Power Voltage, V Current, A Type Length, Weight, Carbon Steel Redalloy* Alloy
Rating, hp Rating, hp ft [m] lbm [kg] Part Number Part Number
1,924 1,603 131.0 UT 32.1 [9.8] 2,323 [1,054.6] 2011095 2011117
2,426 2,022 104.0 UT 32.1 [9.8] 2,323 [1,054.6] 2011063 2011085
2,928 2,440 86.5 UT 32.1 [9.8] 2,323 [1,054.6] 2011064 2011086
3,430 2,858 73.5 UT 32.1 [9.8] 2,323 [1,054.6] 2011065 2011087
3,932 3,277 64.5 UT 32.1 [9.8] 2,323 [1,054.6] 2011066 2011088
420 1,924 350 1,603 131.0 CT 32.2 [9.8] 2,333 [1,059.2] 2011156 2011170
1,924 1,603 131.0 S 33.0 [10.1] 2,391 [1,085.5] 2010930 2010972
2,426 2,022 104.0 S 33.0 [10.1] 2,391 [1,085.5] 2010931 2010973
2,928 2,440 86.5 S 33.0 [10.1] 2,391 [1,085.5] 2010932 2010974
3,430 2,858 73.5 S 33.0 [10.1] 2,391 [1,085.5] 2010933 2010975
3,932 3,277 64.5 S 33.0 [10.1] 2,391 [1,085.5] 2010934 2010976
1,524 1,270 178.0 UT 34.2 [10.4] 2,474 [1,123.2] 2011100 2011122
2,062 1,718 131.0 UT 34.2 [10.4] 2,474 [1,123.2] 2011101 2011123
2,600 2,167 104.0 UT 34.2 [10.4] 2,474 [1,123.2] 2011069 2011091
3,137 2,614 86.5 UT 34.2 [10.4] 2,474 [1,123.2] 2011070 2011092
3,675 3,062 73.5 UT 34.2 [10.4] 2,474 [1,123.2] 2011071 2011093
4,213 3,511 64.5 UT 34.2 [10.4] 2,474 [1,123.2] 2011072 2011094
1,524 1,270 178.0 CT 34.3 [10.5] 2,484 [1,127.7] 2011157 2011171
450 375
2,062 1,718 131.0 CT 34.3 [10.5] 2,484 [1,127.7] 2011158 2011172
1,524 1,270 178.0 S 35.1 [10.7] 2,543 [1,154.5] 2010935 2010977
2,062 1,718 131.0 S 35.1 [10.7] 2,543 [1,154.5] 2010936 2010978
2,600 2,167 104.0 S 35.1 [10.7] 2,543 [1,154.5] 2010937 2010979
3,137 2,614 86.5 S 35.1 [10.7] 2,543 [1,154.5] 2010938 2010980
3,675 3,062 73.5 S 35.1 [10.7] 2,543 [1,154.5] 2010939 2010981
4,213 3,511 64.5 S 35.1 [10.7] 2,543 [1,154.5] 2010940 2010982
Return to Motors
562 Dominator Motors
Return to Motors
738 Dominator Motors
Return to Motors
738 Dominator* Motors—RK Type (continued)
Frequency, 60 Hz Frequency, 50 Hz
Power Voltage, V Power Voltage, V Current, A Type Length, Weight, Carbon Steel Redalloy* Alloy
Rating, hp Rating, hp ft [m] lbm [kg] Part Number Part Number
2,065 1,720 205.9 UT 27.1 [8.3] 3,363 [1,526.8] 2013242 2013249
2,065 1,720 205.9 LT 26.6 [8.1] 3,363 [1,526.8] 2013068 2013085
700 2,604 583 2,169 163.3 S 27.1 [8.3] 3,363 [1,526.8] 2012396 2012499
3,142 2,617 135.3 S 27.1 [8.3] 3,363 [1,526.8] 2012397 2012500
4,220 3,515 100.8 S 27.1 [8.3] 3,363 [1,526.8] 2012398 2012501
2,212 1,843 206.0 UT 28.7 [8.8] 3,598 [1,633.5] 2001634 2013250
2,212 1,843 206.0 LT 28.3 [8.6] 3,598 [1,633.5] 2013069 2013086
750 2,212 625 1,843 206.0 S 28.8 [8.8] 3,598 [1,633.5] 2013305 2013311
3,367 2,805 135.3 S 28.8 [8.8] 3,598 [1,633.5] 2012399 2012502
3,943 3,285 115.5 S 28.8 [8.8] 3,598 [1,633.5] 2012400 2012503
2,360 1,966 205.9 S 30.4 [9.3] 3,832 [1,739.7] 2013306 2013312
800 2,975 666 2,478 163.3 S 30.4 [9.3] 3,832 [1,739.7] 2012401 2012504
3,591 2,991 135.3 S 30.4 [9.3] 3,832 [1,739.7] 2012402 2012505
2,507 2,088 206.0 S 32.0 [9.8] 4,066 [1,846.0] 2013307 2013313
850 3,161 708 2,633 163.3 S 32.0 [9.8] 4,066 [1,846.0] 2012403 2012506
3,815 3,178 135.3 S 32.0 [9.8] 4,066 [1,846.0] 2012404 2012507
3,347 2,788 163.3 S 33.7 [10.3] 4,300 [1,955.2] 2012406 2012509
900 750
4,040 3,365 135.3 S 33.7 [10.3] 4,300 [1,955.2] 2012405 2012508
Return to Motors
738 Dominator Motors
Return to Motors
738 Dominator* Motors—RX Type with Integral Phoenix* Sensor Adapter (continued)
Frequency, 60 Hz Frequency, 50 Hz
Power Voltage, V Power Voltage, V Current, A Type Length, Weight, Carbon Steel Redalloy* Alloy
Rating, hp Rating, hp ft [m] lbm [kg] Part Number Part Number
2,360 1,966 205.9 S 30.6 [9.3] 3,832 [1,739.7] 2013344 2013350
800 2,975 666 2,478 163.3 S 30.6 [9.3] 3,832 [1,739.7] 2013131 2013207
3,591 2,991 135.3 S 30.6 [9.3] 3,832 [1,739.7] 2013132 2013208
2,507 2,088 206.0 S 32.2 [9.8] 4,066 [1,846.0] 2013345 2013351
850 3,161 708 2,633 163.3 S 32.2 [9.8] 4,066 [1,846.0] 2013133 2013209
3,815 3,178 135.3 S 32.2 [9.8] 4,066 [1,846.0] 2013134 2013210
3,347 2,788 163.3 S 33.8 [10.3] 4,300 [1,952.2] 2013135 2013212
900 750
4,040 3,365 135.3 S 33.8 [10.3] 4300, [1,952.2] 2006498 2013211
Return to Motors
Maximus* Components
Operational efficiency
Features
Operational and equipment problems,
■ Factory prefilled and preshimmed such as ESP failure within the first 90
system days of operation, can require substan-
■ Integrated protector assembly tial troubleshooting efforts and non-
■ Direct connect motor pothead productive time. By reducing the
■ Integrated Phoenix* real-time installation complexity, the ProMotor
pressure and temperature sensor unit improves REDA Maximus ESP
system reliability and performance
through simplified wellsite assembly.
Integrated ESP systems The ease of installation also helps save
costly rig time during installation.
REDA* Maximus* ESP systems are the
The integrated Phoenix sensor pro-
next evolution in the continuous inno-
vides continuous equipment perform-
vation and improvement of REDA ESP
ance measurements to help operators
technology. These next-generation
anticipate production problems. They
ESP systems deliver improved relia-
can also apply petroleum engineering
bility and performance through the
analysis to better understand the
use of integrated components with
well’s production potential.
fewer mechanical connections. This
Combined with the Schlumberger
field friendly system reduces early-life
espWatcher* surveillance and control
failures and extends ESP run life. A
system, operators can proactively
key component in the improved
enhance their ESP operations to
Maximus ESP system is the newly
improve production and equipment
developed ProMotor unit.
run life.
Nomenclature Definitions
Type Description
66L Two-chambered labyrinth design
SB Positive seal protector using a single elastomeric bag
DB Positive seal protector with two elastomeric bags connected in parallel
PF Prefilled protector
HL High-load thrust bearing
HSS Indicates the use of high-strength shaft
HTM Indicates the use of high-temperature materials in the protector
Back to Cables
REDA ESP Power Cable
Back to Cables
Modular cable nomenclature
In line with the modular cable design
philosophy, we are using descriptive
nomenclature that uniquely identifies
the components of each specific cable.
The designations indicate the materi-
als selected, starting from the insula-
tion, working out to the barrier, jacket,
armor, kilovolt rating, and shape.
Insulation
PPE Polypropylene copolymer
P Polyethylene copolymer
E EPDM rubber
K Kapton® film
T Semiconductive tape
S Special
Jacket
PE High-density polyethylene
O Oil-resistant nitrile rubber formulation (four temperature ratings)
E EPDM rubber
Cable Armor
# Armor thickness, in.
G Galvanized steel
HG Heavy galvanized steel
GG Double-layer galvanized steel
SS Stainless steel
M MONEL® alloy
FP Flat-profile interlocking armor
Back to Cables
Polyethylene
Applications Description
■ Electrical power cable for This unarmored cable is designed
submersible pumping systems primarily for water wells or oil wells
■ Conductors rated for well with low oil cut and low BHP.
temperatures to 180°F [82°C] As with all REDA* ESP power
cables, any cable can be manufac-
tured using RedaTube* cable manu-
Benefits facturing technology. These cables
■ Uses alloy-coated conductors are useful when a hydraulic conduit
for corrosion protection is required for operation of safety
valves, chemical injection, or other
■ Contains proprietary polypropyl- similar applications.
ene copolymer for damage and
chemical resistance
Components
The jacket is made from a proprietary
Features HDPE compound with improved flexi-
■ Proprietary high-density polyeth- bility and toughness.
ylene (HDPE) compound jacket Polypropylene copolymer gives
damage and chemical resistance to the
insulation. PPEPE
The maximum conductor tempera-
ture is 180°F [82°C] based on the
options selected. The conductors are
made of alloy-coated copper to pro-
tect against corrosion and improve
long-term electrical properties of the
insulation.
Back to Cables
Description AWG Conductor Conductor Insulation Overall Unit
Size/Type Diameter, Diameter, Dimensions, Weight,
in. [mm] in. [mm] in. [mm] lbm/ft [kg/m]
1/stranded 0.328 [8.33] 0.478 [12.14] 1.187 [30.15] 1.19 [1.77]
2/stranded 0.292 [7.42] 0.442 [11.23] 1.110 [28.19] 0.98 [1.46]
(PPEPE) O4R 4/solid 0.204 [5.18] 0.354 [8.99] 0.921 [23.39] 0.63 [0.94]
6/solid 0.162 [4.11] 0.312 [7.92] 0.830 [21.08] 0.45 [0.67]
8/solid 0.128 [3.25] 0.279 [7.09] 0.758 [19.25] 0.33 [0.49]
Notes: Dimensions are nominal.
Weight tolerance is ±4 %.
Materials and specifications are subject to change without notice.
Tolerances, in. [mm]: insulation, ±0.012 [0.305]; overall, ±0.030 [0.762]
Back to Cables
Redalene Cable
Applications Description
■ Electrical power cable for All cable designs in the Redalene*
submersible pumping systems ESP power cable family use poly-
■ Conductors rated for well propylene insulation (designated P or
temperatures to 205°F [96°C] PPE) and an oil-resistant nitrile
jacket (designated O).
Several common cable designs in
Benefits the family are shown. Many other
■ Includes corrosion protection for designs are available depending on
the copper conductors the options selected.
As with all REDA* ESP power
■ Contains proprietary insulation for POTB
cables, any cable can be manufac-
damage and chemical resistance tured using RedaTube* cable manu-
■ Incorporates barrier to prevent facturing technology. These cables
failure from chemical attack and are useful when a hydraulic conduit
gas decompression is required for operation of safety
■ Provides armor options to resist valves, chemical injection, or other
corrosion and mechanical damage similar applications.
Back to Cables
Redalene Flat Cable Redalene Flat Cable
250 350
No. 2/0 Conductor No. 2/0 Conductor
No. 1/0 Conductor 300 No. 1/0 Conductor
200 No. 1 Conductor No. 1 Conductor
No. 2 Conductor 250 No. 2 Conductor
No. 4 Conductor No. 4 Conductor
Maximum 150 No. 6 Conductor Maximum 200 No. 6 Conductor
conductor conductor
current, 100 current, 150
A A
100
50
50
0 0
0 50 100 150 200 250 0 50 100 150 200 250
Maximum well temperature, °F Maximum well temperature, °F
‡ Tolerances, in. [mm]: insulation, ±0.012 [0.305]; jacket, minor, ±0.030 [0.762], major, ±0.040 [1.016]; overall, minor, ±0.040 [1.016], major, ±0.045 [1.143]
§ Tolerances, in. [mm]: insulation, ±0.012 [0.305]; jacket, ±0.030 [0.762]; overall, ±0.035 [0.889]
Back to Cables
Redahot Cable
Applications Description
■ Electrical power cable for All cable designs in the Redahot* ESP
submersible pumping systems power cable family use a proprietary
■ Conductors rated for well EPDM insulation (designated E) and
temperatures from 220 to 350°F an oil-resistant nitrile jacket (desig-
[121 to 177°C] nated O).
Several common cable designs in
the family are shown. Many other
Benefits designs are available depending on the
■ Contains barrier to prevent options selected.
failure from chemical attack As with all REDA* ESP power
cables, any cable can be manufac- EO
and gas decompression
tured using RedaTube* cable manu-
■ Includes alloy coating for facturing technology. These cables
corrosion protection are useful when a hydraulic conduit
■ Offers armor options to resist cor- is required for operation of safety
rosion and mechanical damage valves, chemical injection, or other
similar applications.
Features
■ Alloy-coated copper conductors Components ESO
■ Ethylene propylene diene Alloy coating provides corrosion pro-
methylene (EPDM) insulation tection for copper and prevents degra-
dation of the adhesive bond between
■ Option of taped and extruded conductor and the EPDM insulation.
barriers EPDM insulation compounds pro-
■ Patented EPDM and nitrile rubber vide the optimum combination of
jacket compounds electrical, physical, and chemical
■ Cable armor standard with steel properties. Barriers prevent failure
ETBO
strips and galvanized coating from chemical attack and gas decom-
on all sides pression, enabling performance in
high-temperature wells with hostile
environments or high gas/oil ratios.
Armor options can improve resis-
tance to corrosion and mechanical
damage.
Back to Cables
350
No. 2/0 Conductor
300 No. 1/0 Conductor
No. 1 Conductor
No. 2 Conductor
250 No. 4 Conductor
No. 6 Conductor
Maximum 200
conductor
current,
150
A
100
50
0
0 50 100 150 200 250 300
Maximum well temperature, °F
Back to Cables
Redablack Cable
Applications Description
■ Electrical power cable for All cable designs in the Redablack*
submersible pumping systems ESP power cable family use a propri-
■ Conductors rated for well etary EPDM insulation formulation
temperatures from 300 to 400°F and EPDM jacket (both designated
[149 to 204°C] E). This specialized EPDM insulation
is based on experience in rubber
EFE
compounding and mixing for the oil
Benefits industry.
■ Includes alloy coating for corro- Several common cable designs in
sion protection the family are shown. Many other
designs are available depending on
■ Contains barrier to prevent fail- the options selected.
ures from chemical attack and As with all REDA* ESP power
gas decompression cables, any cable can be manufac-
■ Uses jacket compounds to tured using RedaTube* cable manu-
increase physical properties and ETBE-400
facturing technology. These cables
temperature capabilities are useful when a hydraulic conduit
■ Offers armor options to resist gas, is required for operation of safety
corrosion, and mechanical damage valves, chemical injection, or other
similar applications.
Features
■
Components
Alloy-coated copper conductors
The conductor temperature range is
■ Option of taped and extruded EER
300 to 400°F [149 to 204°C]. Alloy
barriers coating provides corrosion protection
■ Proprietary ethylene propylene for the copper conductors and pre-
diene methylene (EPDM) rubber vents degradation of the adhesive
jacket compounds bond between the conductor and the
■ Cable armor standard with steel EPDM insulation.
strips and a galvanized coating Barriers prevent failures from
on all sides chemical attack and gas decompres- ETBEF-300
sion, enabling performance in high-
temperature wells with hostile
environments or high gas/oil ratios.
Several types of taped and extruded
barriers are available.
Jacket compounds provide excep-
tional physical properties and tem-
perature capabilities.
Cable armor made from steel strips
featuring a galvanized coating on all
sides is standard. Armor options can
improve resistance to gas, corrosion,
and mechanical damage.
Back to Cables
Redablack 300 Round Redablack 400 Round
400
No. 2/0 Conductor 450
350 No. 1/0 Conductor No. 2/0 Conductor
No. 1 Conductor 400 No. 1/0 Conductor
No. 1 Conductor
300 No. 2 Conductor 350 No. 2 Conductor
No. 4 Conductor
300 No. 4 Conductor
Maximum 250 No. 6 Conductor
Maximum No. 6 Conductor
conductor conductor 250
200
current, current, 200
A 150 A 150
100 100
50 50
0 0
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350 400 450
Maximum well temperature, °F Maximum well temperature, °F
‡ Tolerances, in. [mm]: insulation, ±0.012 [0.305]; jacket, minor, ±0.030 [0.762], major, ±0.040 [1.016]; overall, minor, ±0.040 [1.016], major, ±0.045 [1.143]
Back to Cables
Redalead Cable
Applications Description
■ Electrical power cable for sub- All cable designs in the Redalead*
mersible pumping systems ESP power cable family use a propri-
■ Conductors rated for well etary EPDM insulation formulation
temperatures from 400 to 450°F (designated E) and an impervious
[204 to 232°C] lead barrier (designated L).
Common cable designs in the fam-
ily are shown. Many other designs are
Benefits available depending on the options
■ Alloy coating for corrosion selected.
protection As with all REDA* ESP power
cables, any cable can be manufac-
■ Lead barrier to prevent failure tured using RedaTube* cable manu-
from chemical attack and gas facturing technology. These cables
decompression are useful when a hydraulic conduit
■ Armor options to resist gas, corro- is required for operation of safety ELB
sion, and mechanical damage valves, chemical injection, or other
similar applications.
Features
■ Alloy-coated copper conductors Components
■ Ethylene propylene diene The conductor alloy coating provides
methylene (EPDM) insulation corrosion protection for the copper
and prevents degradation of the
■ Fatigue- and corrosion-resistant adhesive bond between the conduc-
lead tor and the EPDM insulation. ELBE
■ Various barrier and jacket types Insulation compounds provide the
■ Cable armor standard with steel optimum combination of electrical,
strips and a galvanized coating physical, and chemical properties.
on all sides The conductor temperature range is
400 to 450°F [204 to 232°C] based on
the options selected.
A lead barrier prevents failure
from chemical attack and gas decom-
pression, enabling performance in
high-temperature wells with hostile
environments or high gas/oil ratios.
Additional barriers and jacket types
are available to prevent mechanical
damage and to maximize cable run life.
Armor options can improve resis-
tance to gas, corrosion, and mechan-
ical damage.
Back to Cables
Redalead Flat Redalead Round
400 450
No. 2/0 Conductor No. 2/0 Conductor
350 No. 1/0 Conductor 400 No. 1/0 Conductor
No. 1 Conductor No. 1 Conductor
300 No. 2 Conductor
350 No. 2 Conductor
No. 4 Conductor No. 4 Conductor
Maximum Maximum 300
250 No. 6 Conductor No. 6 Conductor
conductor conductor 250
200
current, current, 200
A 150 A 150
100 100
50 50
0 0
0 50 100 150 200 250 300 350 400 450 500 0 50 100 150 200 250 300 350 400 450
Maximum well temperature, °F Maximum well temperature, °F
‡ Tolerances, in. [mm]: insulation, ±0.012 [0.305]; jacket, ±0.030 [0.762]; overall, ±0.035 [0.889]
Back to Cables
RedaCDC Cable
Applications Description
■ Electrical power cable for With materials specifically designed
submersible pumping systems for Southeast Asia, the RedaCDC*
■ Conductors rated for well ESP power cable family offers many
temperatures from 300 to 400°F options for tailoring the cable design
[149 to 204°C] to a precise set of operating condi-
tions. All RedaCDC cables use a pro-
prietary EPDM insulation formulation SESO
Benefits (designated SE) compounded for the
■ Contains alloy for corrosion high temperatures and high gas/oil
protection ratio conditions of Southeast Asia.
Common cable designs in the
■ Includes barrier to prevent family are shown. Many other designs
failures from chemical attack are available depending on the
and gas decompression options selected.
■ Provides armor options to resist As with all REDA* ESP power
gas, corrosion, and mechanical cables, any cable can be manufac- SEFE
damage tured using RedaTube* cable manu-
facturing technology. These cables
are useful when a hydraulic conduit
Features is required for operation of safety
■ Alloy-coated copper conductors valves, chemical injection, or other
■ Ethylene propylene diene similar applications.
methylene (EPDM) insulation
■ Option of taped and extruded Components SETBO
barriers Alloy coating provides corrosion pro-
■ Proprietary EPDM and nitrile tection for copper and prevents degra-
rubber jacket compounds dation of the adhesive bond between
■ Cable armor standard with steel conductor and the EPDM insulation.
strips and a galvanized coating Insulation compounds provide the
on all sides optimum combination of electrical,
physical, high-temperature, and
chemical properties. The conductor
SETBE-400
temperature range is 300 to 400°F
[149 to 204°C] based on the options
selected.
Barriers prevent failures from attack
and gas decompression, ensuring supe-
rior performance in high-temperature
wells with hostile environments or
wells with high gas/oil ratios. Several
types of taped and extruded barriers
are available.
Armor options can improve resis-
tance to gas, corrosion, and mechani-
cal damage.
Back to Cables
Description AWG Conductor Insulation Jacket Overall Unit
Conductor Diameter, Diameter, Diameter, Dimensions, Weight,
Size/Type in. [mm] in. [mm] in. [mm] in. [mm] lbm/ft [kg/m]
1/compacted 0.297 [7.54] 0.477 [12.12] 1.228 [31.19] 1.398 [35.51] 1.84 [2.74]
1/solid 0.289 [7.34] 0.469 [11.91] 1.212 [30.78] 1.382 [35.10] 1.80 [2.68]
(SESO) G5R† 2/compacted 0.268 [6.81] 0.448 [11.38] 1.166 [29.62] 1.336 [33.93] 1.59 [2.37]
2/solid 0.258 [6.55] 0.438 [11.13] 1.143 [29.03] 1.313 [33.35] 1.55 [2.31]
4/solid 0.204 [5.18] 0.384 [9.75] 1.029 [26.14] 1.199 [30.45] 1.22 [1.82]
1/compacted 0.297 [7.54] 0.477 [12.12] 1.228 [31.19] 1.398 [35.51] 1.94 [2.89]
1/solid 0.289 [7.34] 0.469 [11.91] 1.212 [30.78] 1.382 [35.10] 1.83 [2.72]
(SEFE) G5R† 2/compacted 0.268 [6.81] 0.448 [11.38] 1.166 [29.62] 1.336 [33.93] 1.60 [2.38]
2/solid 0.258 [6.55] 0.438 [11.13] 1.143 [29.03] 1.313 [33.35] 1.58 [2.35]
4/solid 0.204 [5.18] 0.384 [9.75] 1.029 [26.14] 1.199 [30.45] 1.24 [1.85]
1/compacted 0.297 [7.54] 0.477 [12.12] 1.207 [30.66] 1.377 [34.98] 1.87 [2.78]
1/solid 0.289 [7.34] 0.469 [11.91] 1.190 [30.23] 1.360 [34.54] 1.75 [2.60]
(SETBO) G5R† 2/compacted 0.268 [6.81] 0.448 [11.38] 1.144 [29.06] 1.314 [33.38] 1.53 [2.28]
2/solid 0.258 [6.55] 0.438 [11.13] 1.122 [28.50] 1.292 [32.82] 1.51 [2.25]
4/solid 0.204 [5.18] 0.384 [9.75] 1.007 [25.58] 1.177 [29.90] 1.19 [1.77]
1/compacted 0.297 [7.54] 0.477 [12.12] 1.215 [30.86] 1.385 [35.18] 1.92 [2.86]
1/solid 0.289 [7.34] 0.469 [11.91] 1.199 [30.45] 1.369 [34.77] 1.80 [2.68]
(SETBE-400) G5R† 2/compacted 0.268 [6.81] 0.448 [11.38] 1.153 [29.29] 1.323 [33.60] 1.57 [2.34]
2/solid 0.258 [6.55] 0.438 [11.13] 1.130 [28.70] 1.300 [33.02] 1.55 [2.31]
4/solid 0.204 [5.18] 0.384 [9.75] 1.016 [25.81] 1.186 [30.12] 1.22 [1.82]
Notes: Dimensions are nominal.
Weight tolerance is ±4 %.
Materials and specifications are subject to change without notice.
† Tolerances, in. [mm]: insulation, ±0.012 [0.305]; jacket, ±0.030 [0.762]; overall, ±0.035 [0.889]
Back to Cables
RedaValu Cable
Applications Description
■ Electrical power cable for RedaValu* electrical power transmis-
submersible pumping systems sion cables are intended for use in
■ Conductors rated for well low-temperature, nonaggressive wells.
temperatures to 205°F [96°C] This cable type is a cost-effective alter-
native to Redalene* flat cables and
conductors. The RedaValu cables uti-
Benefits lize the same polypropylene insulation
■ Contains alloy coating for (designated P) and tape and braid
corrosion protection (designated TB) as the Redalene
cables, but the oil-resistant nitrile
■ Includes polypropylene copolymer jacket has been eliminated to reduce
insulation to resist damage and the overall cost of the cable system.
chemicals As with all REDA* ESP power
■ Uses fluorocarbon tape barrier cables, any cable can be manufac-
to protect the insulation from tured using RedaTube* cable manu-
chemical attack facturing technology. These cables
are useful when a hydraulic conduit
is required for operation of safety
Features valves, chemical injection, or other
■ Alloy-coated copper conductors similar applications. PTB G4R
■ Proprietary polypropylene
copolymer insulation Components
■ Fluorocarbon tape barrier The alloy coating provides corrosion pro-
■ Cable armor standard with steel tection for the copper and improves
strips and a galvanized coating long-term electrical properties of the
on all sides insulation. Unique polypropylene
copolymer gives improved damage and
chemical resistance while improving
low-temperature flexibility over stan-
dard polypropylene insulation.
Fluorocarbon tape barrier is used
to protect the insulation from chemi-
cal attack.
The conductors are made of alloy-
coated copper. Insulation consists of a
proprietary polypropylene copolymer.
The barrier is fluorocarbon tape.
Cable armor made from steel strips
featuring a galvanized coating on all
sides is standard.
Back to Cables
Description AWG Conductor Insulation Jacket Diameter, Overall Dimensions, Unit
Conductor Diameter, Diameter, in. [mm] in. [mm] Weight,
Size/Type in. [mm] in. [mm] lbm/ft [kg/m]
2/stranded 0.292 [7.42] 0.442 [11.23] 0.562 × 1.546 [14.27 × 39.27] 1.463 × 0.571 [37.16 × 14.50] 1.17 [1.74]
PTB G4R 4/solid 0.204 [5.18] 0.354 [8.99] 0.474 × 1.283 [12.04 × 32.59] 1.199 × 0.483 [30.45 × 12.27] 0.81 [1.21]
6/solid 0.162 [4.11] 0.312 [7.92] 0.432 × 1.156 [10.97 × 29.36] 1.073 × 0.441 [27.25 × 11.20] 0.62 [0.92]
Notes: Dimensions are nominal.
Weight tolerance is ±4 %.
Materials and specifications are subject to change without notice.
Tolerances, in. [mm]: insulation, ±0.012 [0.305]; jacket, ±0.030 [0.762]; overall, ±0.040 [1.016]
Back to Cables
RedaSurface Cable
Back to Cables
Description AWG Conductor Insulation Jacket Overall Unit
Conductor Diameter, Diameter, Diameter, Dimensions, Weight,
Size/Type in. [mm] in. [mm] in. [mm] in. [mm] lbm/ft [kg/m]
1/compacted 0.297 [7.54] 0.509 [12.93] 1.296 [32.92] 1.456 [36.98] 1.79 [2.66]
(TEOPVC) G5R 2/compacted 0.268 [6.81] 0.480 [12.19] 1.233 [31.32] 1.393 [35.38] 1.58 [2.35]
4/solid 0.204 [5.18] 0.416 [10.57] 1.096 [27.84] 1.256 [31.90] 1.24 [1.85]
1/compacted 0.297 [7.54] 0.509 [12.93] 1.296 [32.92] 1.511 [38.38] 1.93 [2.87]
(TEOPVC) PVC G5R 2/compacted 0.268 [6.81] 0.480 [12.19] 1.233 [31.32] 1.448 [36.78] 1.72 [2.56]
4/solid 0.204 [5.18] 0.416 [10.57] 1.096 [27.84] 1.311 [33.30] 1.36 [2.02]
Notes: Dimensions are nominal.
Weight tolerance is ±4 %.
Materials and specifications are subject to change without notice.
Tolerances, in. [mm]: insulation, ±0.012 [0.305]; jacket, ±0.030 [0.762]; overall, ±0.040 [1.016]
Back to Cables
RedaTube Cable Technology
Applications Description
■ Electrical power cable for sub- In addition to three-conductor REDA
mersible pumping systems ESP power cable designs, there is
■ Hydraulic conduit for operation of RedaTube* cable technology for inte-
safety valves, chemical injection, gral stainless-steel tubing. This tubing
or other similar applications can be used for chemical injection or
downhole control applications.
Round and flat designs with the
Benefits integral tube are shown. Cost-effective
■ Combines the power cable and manufacturing incorporates the injec-
injection tube into one package, tion tube during the phase conductor
simplifies workover operations, and cabling operation, resulting in an
prevents damage to the tubing. accurate amount of armor material.
The overall cable size is limited
■ Includes round cable that is more to 3.25-in. [82.55-mm] OD for round
resistant to mechanical damage, cable or maximum axis diameter for
and rolls around restrictions a flat cable design.
encountered during installation. Two standard sizes of injection
tube are available:
Features ■ 0.375-in. [9.53-mm] OD,
Back to Cables
Motorlead Extensions
Applications Description
■ Electrical power cable for sub- Our motorlead extension (MLE)
mersible pumping systems designs provide the optimal combina-
■ Conductors rated for well tion of installation clearance and
temperatures from 250 to 450°F downhole performance. The primary
[121 to 232°C] insulation of polyimide is used to sig-
nificantly reduce cable dimensions.
The same proprietary materials used
Benefits in REDA* ESP power cables are
■ Contains ethylene propylene diene employed in the MLE designs as sec-
methylene (EPDM) insulation ondary insulations and jackets to max-
compounds for optimal combina- imize system reliability.
tion of electrical, physical, and Several common MLE designs are KEOTB
chemical properties shown.
■ Includes barrier to prevent
failures from chemical attack and Components
gas decompression Conductor components are made
from fully annealed, high-conductivity
copper conductors.
Features Primary insulation is made of dual KELB
■ Fully annealed, high-conductivity layers of polyimide tape. Secondary
copper components insulation is a proprietary EPDM
■ Lead and fluorocarbon tape compound.
barriers Lead and fluorocarbon tape barri-
■ Proprietary nitrile rubber jacket ers prevent failures from chemical
compound in the KEOTB attack and gas decompression.
Proprietary nitrile rubber com-
■ Standard galvanized steel and pound with exceptional physical prop-
MONEL® armor erties and oil resistance is used in the
KEOTB jacket design. KELTB
Galvanized steel and MONEL armor
are standard.
Back to Cables
300
No. 1 Conductor
No. 2 Conductor
250 No. 4 Conductor
No. 6 Conductor
200
Maximum
conductor 150
current,
A
100
50
0
0 50 100 150 200 250 300 350 400 450 500
Maximum well temperature, °F
Back to Cables
Lasalle Cable Protectors
Applications Introduction
■ ESP installations During the past 25 years, Lasalle* ESP
■ Completions with downhole gauges cable protectors have been field
■
proven in a wide array of oilfield
Intelligent and standard comple-
applications and in many types of
tions using control line, fiber-
completions. Lasalle protectors from
optic cable or electric cable
Schlumberger are used more often in
subsea, deepwater, and extended-
Benefits reach completions than any other
type of cable protector.
■ Molds control line and cable The all-cast crosscoupling cable
during installation protector is at the core of a wide range
■ Supports the control line rather of manufactured products.
than physically gripping it Cast in either carbon or stainless
■ Prevents damage during dynamic steel, the Lasalle protectors are
motion of production tubing designed to ensure that all control
■ Demounts easily and allows lines and ESP power cables are pro-
reinstallation tected for the full production string
length. By protecting these compo-
■ Reduces the risk of hang up nents from crushing and abrasive
during completion installation forces during installation of the com-
pletion, Lasalle protectors extend the
Features equipment run life, functionality, and
operability of all downhole equip-
■ Optimum standoff ment. Without this protection, dam-
■ Reusable, one-piece design age to the control line and cable could
■ Optimized cable slot lead to premature malfunction or
■ Maximized chamfers completion failure.
Protectors can be custom designed
■ All cast construction to meet specific project requirements,
■ Interlock design of hinge or they can be adapted on site.
and fasteners
■ Locator neck fixing position Crosscoupling cable protectors
■ Weight-reducing pockets Lasalle crosscoupling cable protectors
■ Unique flapper mechanism can be supplied in all-cast, strap-type,
or slimline design.
Strap-type protectors are only
recommended when the internal drift
of the casing is not sufficient to
accommodate the all-cast design.
However, the slimline protector design
provides an all-cast protector for wells
with restricted tubing or tight casing
clearances.
Back to Cables
Crosscoupling protectors are avail- Special application
able for tubing sizes from 2 3⁄8 in. to cable protectors
9 5⁄8 in. and can be produced for all cou-
pling types and all control line and Subsurface safety valve protector
cable specifications. The patented design protects the
Continual design evolution of these control line and cable while it is
protectors, based on client feedback, bypassing large-diameter equipment.
ensures that installation and removal The unique flapper mechanism molds
of the protectors is simple and quick. the control line and cable without rig
When used with a pneumatic kit by an crew assistance to ensure the control
experienced rig crew, the preengaged line and cable are lifted from the
hexagonal head bolt protector can be tubing to exit the protector parallel
installed in approximately 20 s. The self- to the valve body. The protector
locating fastening mechanism mini- securely captures the control line and
mizes the potential for thread damage. cable in the protector body. The unit is
designed to resist axial movement by
locating a cast internal lip profile in
Harsh environment the gap between the flow coupling and
cable protector the equipment sub or a groove
In subsea wells, the completion string machined in the flow coupling.
is subjected to excessive cyclical This protector is available for popu-
action caused by heave, rig misalign- lar tubing sizes, and the range of sizes
ment, or both. is being extended continuously. The
Harsh environment protectors are standard Lasalle subsurface safety
available for tubing sizes from 3 in. to valve (SSSV) control line protector
7 in. and can be provided for all cou- is available for all tubing sizes.
pling types and all control line and Side-pocket mandrel protector
cable specifications. In conjunction with the development
of the new SSSV control line/cable
Motorlead extension protector, a new side-pocket mandrel
cable protector (SPM) protector has also been devel-
oped. This unit incorporates the same
Two motorlead extension (MLE) protection capabilities as the SSSV
protectors are available in an all-cast control line protector, with the excep-
body design, typically with a stainless tion of the flapper mechanism. The
steel saddle clamp. One MLE protec- minimal step between the tubing and
tor is specifically for the pothead the mandrel body leaves insufficient
location and the other is for the room to locate the flapper in this unit.
tandem equipment above and below This protector is available for popular
the motor pothead. tubing sizes, and the range of sizes is
The MLE designs are centralized or being extended continuously. The stan-
noncentralized types to meet specific dard Lasalle SPM protector is available
completion requirements. These for all tubing sizes.
protectors can be provided to meet
all pump string combinations and all
control line and cable specifications.
Lasalle MLE protectors are
designed for quick and simple installa-
tion. These protectors are typically
designed with a preengaged hexagonal
head bolt. Because this mechanism is
self-locating, the potential for thread
damage is minimized, saving time
during installation.
Back to Cables
Power Cable
Back to Cables
Redalene* PPEO Round Cable
Description AWG Conductor OD, in. [mm] Weight, Part Number
Size/Type lbm/ft [kg/m]
1/0/stranded compacted 1.44 [36.60] 2.10 [3.12] 1035559
1/stranded compacted 1.36 [34.42] 1.79 [2.66] 977173
Galvanized armor, 5-kV voltage rating 2/0/stranded 1.61 [40.82] 2.46 [3.66] 829036
2/stranded compacted 1.29 [32.84] 1.46 [2.17] 977181
4/solid 1.16 [29.36] 1.11 [1.65] 901603
1/0/stranded compacted 1.43 [36.35] 2.04 [3.04] 1071794
MONEL® armor, 5-kV voltage rating 1/stranded compacted 1.35 [34.16] 1.74 [2.59] 861435
2/stranded compacted 1.28 [32.59] 1.41 [2.10] 1096312
Flat profile, galvanized armor, 4/solid 1.04 [26.31] 1.11 [1.65] 1206614
4-kV voltage rating
1/stranded 1.36 [34.47] 1.72 [2.56] 742361
2/stranded 1.28 [32.51] 1.48 [2.20] 742379
Galvanized armor, 4-kV voltage rating
4/solid 1.09 [27.71] 1.05 [1.56] 742791
6/solid 1.00 [25.40] 0.83 [1.24] 744854
1/stranded 1.35 [34.21] 1.66 [2.47] 507608
2/stranded 1.27 [32.26] 1.43 [2.13] 868695
MONEL armor, 4-kV voltage rating
4/solid 1.08 [27.51] 1.00 [1.49] 816934
6/solid 0.99 [25.25] 0.79 [1.18] 826107
Flat profile, stainless steel armor, 2/stranded 1.20 [30.53] 1.45 [2.16] 1071398
4-kV voltage rating
Stainless steel armor, 4-kV voltage rating 4/solid 0.96 [24.46] 1.00 [1.49] 1060920
Back to Cables
Power Cable
Back to Cables
Redablack* EER Round Cable
Description AWG Conductor OD, in. [mm] Weight, Part Number
Size/Type lbm/ft [kg/m]
1/stranded compacted 1.38 [34.93] 2.06 [3.07] 1144526
Heavy galvanized armor, 5-kV voltage rating 2/stranded compacted 1.31 [33.35] 1.71 [2.54] 1000116
4/solid 1.18 [29.87] 1.34 [1.99] 1000157
1/stranded compacted 1.36 [34.42] 1.86 [2.77] 979237
Galvanized armor, 5-kV voltage rating 2/stranded compacted 1.29 [32.84] 1.52 [2.26] 979245
4/solid 1.16 [29.26] 1.17 [1.74] 1000736
1/0/stranded compacted 1.43 [36.35] 2.11 [3.14] 1039023
1/stranded compacted 1.35 [34.16] 1.81 [2.69] 973370
MONEL® armor, 5-kV voltage rating
2/stranded compacted 1.28 [32.59] 1.47 [2.19] 973305
4/solid 1.15 [29.11] 1.12 [1.67] 973222
2/strand compacted 1.28 [32.59] 1.42 [2.11] 1203496
Stainless steel armor, 5-kV voltage rating
4/solid 1.15 [29.11] 1.08 [1.61] 1203504
1/stranded 1.36 [34.47] 1.77 [2.63] 973339
Galvanized armor, 4-kV voltage rating
6/solid 1.00 [25.40] 0.87 [1.29] 973107
Back to Cables
Power Cable
Galvanized armor, 5-kV voltage rating 2/stranded compacted 0.68 × 2.36 [17.35 × 59.92] 2.66 [3.96] 1245810
with 3⁄8-in. [9.53-mm] stainless steel tube
1/stranded compacted 0.76 × 1.79 [19.35 × 45.36] 2.95 [4.39] 977231
Double galvanized armor, 5-kV voltage rating
2/stranded compacted 0.73 × 1.70 [18.62 × 43.15] 2.56 [3.81] 977249
1/stranded compacted 0.65 × 1.71 [16.56 × 43.33] 2.39 [3.56] 977215
Galvanized armor, 5-kV voltage rating
2/stranded compacted 0.62 × 1.62 [15.82 × 41.12] 2.02 [3.01] 977223
1/stranded 0.77 × 1.84 [19.56 × 46.66] 2.95 [4.39] 872143
Double galvanized armor, 4-kV voltage rating 2/stranded 0.74 × 1.73 [18.87 × 43.92] 2.64 [3.93] 872127
4/solid 0.64 × 1.41 [16.13 × 35.69] 1.96 [2.92] 872226
1/stranded 0.67 × 1.76 [17.00 × 44.63] 2.37 [3.53] 872200
2/stranded 0.63 × 1.65 [16.08 × 41.88] 2.09 [3.11] 872184
Galvanized armor, 4-kV voltage rating
4/solid 0.53 × 1.33 [13.34 × 33.66] 1.50 [2.23] 872168
6/solid 0.48 × 1.20 [12.27 × 30.45] 1.24 [1.85] 923094
1/stranded 0.67 × 1.76 [17.00 × 44.63] 2.44 [3.63] 872218
2/stranded 0.63 × 1.65 [16.08 × 41.88] 2.16 [3.21] 872192
MONEL® armor, 4-kV voltage rating
4/solid 0.53 × 1.33 [13.34 × 33.66] 1.55 [2.31] 872176
6/solid 0.48 × 1.20 [12.27 × 30.45] 1.28 [1.90] 923102
Back to Cables
Redalead* ELBE Round Cable
Description AWG Conductor OD, in. [mm] Weight, Part Number
Size/Type lbm/ft [kg/m]
1/stranded compacted 1.48 [37.47] 2.78 [4.14] 1244730
Galvanized armor, 5-kV voltage rating
2/stranded compacted 1.41 [35.89] 2.49 [3.71] 1249614
MONEL® armor, 4-kV voltage rating 1/stranded 1.50 [38.15] 2.858 [4.25] 1242049
Stainless steel armor, 4-kV voltage rating 2/solid 1.37 [34.87] 2.29 [3.41] 1250893
0.025 Class II galvanized armor, 1/solid 0.67 × 2.22 [13.84 × 35.18] 3.29 [4.90] 7009186
⁄8-in. [9.53-mm] OD × 0.049-in. [1.25-mm]
3
wall capillary tube, 5-kV voltage rating 1/stranded compacted na† 3.30 [4.91] tba‡
† not available
‡ to be assigned
Back to Cables
Power Cable
RedaSurface TEOPVC–PVC
Description AWG Conductor OD, in. [mm] Weight, Part Number
Size/Type lbm/ft [kg/m]
1/stranded compacted 1.51 [38.38] 1.93 [2.87] 1253681
Galvanized armor, 5-kV voltage rating 2/stranded compacted 1.45 [36.78] 1.72 [2.56] 1253699
4/solid 1.31 [33.30] 1.36 [2.02] 1253707
Back to Cables
Motorlead Extensions
375 Series, 3-kV KELTB (Low Profile), 0.392-in. × 0.966-in. [9.96-mm × 24.54-mm] OD
AWG Armor Pothead Length, ft [m] Weight, lbm [kg] Part Number
Conductor Size Design
30 [9] 25 [11] 409441
40 [12] 33 [15] 409474
55 [17] 45 [20] 381764
6 MONEL® Tape in
70 [17] 57 [26] 381772
80 [24] 66 [30] 1035153
90 [27] 74 [34] 947796
Back to Cables
456 Series, 4-kV KELB, 0.464-in. × 1.142-in. [11.79-mm × 29.01-mm] OD
AWG Armor Pothead Length, ft [m] Weight, lbm [kg] Part Number
Conductor Size Design
30 [9] 34 [15] 406207
40 [12] 45 [20] 406215
55 [17] 62 [28] 406223
70 [21] 78 [35] 406231
6 Galvanized Tape in 80 [24] 90 [41] 418079
90 [27] 101 [46] 462200
100 [30] 112 [51] 499111
110 [34] 123 [56] 946186
120 [37] 134 [61] tba†
† to be assigned
Back to Cables
Motorlead Extensions
Back to Cables
540/562 Series, 5-kV KELB, 0.506-in. × 1.308-in. [12.85-mm × 33.22-mm] OD
AWG Armor Pothead Length, ft [m] Weight, lbm [kg] Part Number
Conductor Size Design
30 [9] 47 [21] tba†
40 [12] 62 [28] tba
55 [55] 85 [39] tba
70 [21] 109 [49] 1252816
80 [24] 124 [56] 7000433
4 MONEL® Tape in 90 [27] 140 [63] 2000317
100 [30] 155 [70] tba
110 [34] 170 [77] tba
120 [37] 186 [84] 1184894
130 [40] 200 [91] 7006471
200 [61] 310 [140] 1162270
† to be assigned
Back to Cables
Motorlead Extensions
Back to Cables
Maximus 300 Motorlead Extensions
Back to Cables
ProMotor Lead Extensions
Back to Cables
Fixed Speed Drives
FixStar* 600
Description Max. Voltage Current Weight, Part Number Part Number
Rating, V Rating, A lbm [kg] (Base Model) (400- to 1,000-V Backspin Protection)
FixStar 600-45 600 45 250 [114] 100151381 100135121
FixStar 600-90 600 90 250 [114] 100151379 100135109
FixStar 600-135 600 135 250 [114] 100151182 100120627
Note: Each FixStar drive comes with a UniConn* controller, but with no Bristol amp chart recorder.
FixStar 1500
Description Max. Voltage Current Weight, Part Number Part Number
Rating, V Rating, A lbm [kg] (Base Model) (800- to 2,000-V Backspin Protection)
FixStar 1500-70 1,500 60 1,100 [499] 100228228 100228223
FixStar 1500-130 1,500 125 1,100 [499] 100228226 100228221
FixStar 1500-170 1,500 150 1,100 [499] 100228225 100228220
FixStar 1500-200 1,500 200 1,100 [499] 100228224 100218365
Note: Each FixStar drive comes with a UniConn controller, but with no Bristol amp chart recorder.
FixStar 3300
Description Max. Voltage Current Weight, Part Number Part Number
Rating, V Rating, A lbm [kg] (Base Model) (1,800- to 4,000-V Backspin Protection)
FixStar 3300-70 3,300 70 1,100 [499] 100151203 100129046
FixStar 3300-130 3,300 130 1,100 [499] 100151202 100129018
FixStar 3300-170 3,300 170 1,100 [499] 100151198 100128973
FixStar 3300-200 3,300 200 1,100 [499] 100151195 100128667
Note: Each FixStar drive comes with a UniConn controller, but with no Bristol amp chart recorder.
FixStar 5000
Description Max. Voltage Current Weight, Part Number Part Number
Rating, V Rating, A lbm [kg] (Base Model) (3,000- to 5,000-V Backspin Protection)
FixStar 5000-70 5,000 70 1,100 [499] 100151193 100128303
FixStar 5000-130 5,000 130 1,100 [499] 100151189 100128300
FixStar 5000-170 5,000 170 1,100 [499] 100151188 100128298
FixStar 5000-200 5,000 200 1,100 [499] 100151187 100128274
Note: Each FixStar drive comes with a UniConn controller, but with no Bristol amp chart recorder.
† not applicable
SpeedStar SWD VSDs—NEMA 3R, 6 Pulse, 104°F [40°C] Ambient Temperature Rated
SpeedStar SWD VSDs—NEMA 3R, 12 Pulse, 122°F [50°C] Ambient Temperature Rated
SpeedStar 2000 Plus VSDs—NEMA 3R, 6 Pulse, 104°F [40°C] Ambient Temperature Rated
SpeedStar 2000 Plus VSDs—NEMA 3R, 12 Pulse, 104°F [40°C] Ambient Temperature Rated
SpeedStar 2000 Plus VSDs—NEMA 1, 6 Pulse, 122°F [50°C] Ambient Temperature Rated
SpeedStar 2000 Plus VSDs—NEMA 1, 12 Pulse, 122°F [50°C] Ambient Temperature Rated
SpeedStar 2000 Plus VSDs—NEMA 1, 12 Pulse, 104°F [40°C] Ambient Temperature Rated
StarView* Software
Description Part Number
StarView software for Windows® 2000 and Windows XP tba†
StarView software serial connection cable between UniConn controller and computer 100052238
† to be assigned
Applications
■ Variable speed drives (VSDs)
■ Programmable logic controllers
■ Progressive cavity pump top drives
■ Beam pump motors
■ Pumpoff controllers
■ Instrumentation
Benefits
■ Increased current handling
capability (up to 200 kA)
■ Reduced residual voltage of
metal oxide varistor (MOV)-based
products
■ Improved operations safety
■ Enhanced system reliability
■ Improved equipment protection
Features
■ Operation without fuses
■ UL listed
■ Optional installation with large
size cables or directly on bus bars
(inline connection)
■ NEMA 4 enclosure rating
■ All products within specified
tolerances
■ 10-yr warranty
VSD enclosures
Schlumberger also designs and manu-
factures outdoor-rated enclosures that
house the VSD, line reactors, and asso-
ciated controls and auxiliaries. The
enclosures are completely sealed
and climate-controlled to maintain
a constant temperature in a dust-free
environment.
StarShield TVSS External Retrofit Kits for Third-Party VSDs (for installation at the input)
Part Number
100261002 100261003 100261004 100261005
Nominal system voltage, V 760 (L-L) 760 (L-L) 760 (L-L) 760 (L-L)
Clamping voltage, peak (RMS) 607 (429) 833 (589) 607 (429) 833 (589)
StarShield modules 100220423 100220424 100220423 100220424
Modes of protection L-G, L-L L-G, L-L L-G, L-L L-G, L-L
Number of modules 3 3 3 3
Surge rating per module, kA 120 200 120 200
Dimensions (H × W × D), in. [cm] 20 × 16 × 8 20 × 16 × 8 20 × 16 × 8 20 × 16 × 8
[50.8 × 40.6 × 20.3] [50.8 × 40.6 × 20.3] [50.8 × 40.6 × 20.3] [50.8 × 40.6 × 20.3]
Cable size, AWG no. 2 2 2 2
SpeedStar VSD type 6 pulse 6 pulse 6 pulse 6 pulse
Enclosure rating NEMA 4 NEMA 4 NEMA 4 NEMA 4
Surge counter ready No No Yes Yes
Fuses included Yes Yes Yes Yes
Junction Boxes
Description Voltage Weight, Dimensions Part Number
Rating, kV lbm [kg] (W × H × D),
in. [cm]
Explosion-proof wellhead junction box 5 250 114] 24 × 30 × 14 100021798
[61 × 76 × 36]
Wellhead junction box, NEMA 3R 5 50 [23] 20 × 22 × 10 AC01130
[51 × 56 × 25]
Wellhead junction box, stainless steel Type 316, 5 60 [27] 20 × 20 × 9 AC01174
NEMA 4X [51 × 51 × 23]